HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Size: px
Start display at page:

Download "HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer"

Transcription

1 Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower Engineered Air Products

2 Moisture in compressed air is damaging. Without proper treatment, this vital energy source is a wet, gritty, acidic brew, silently destroying all that it comes in contact with. hold the key for systems requiring high quality, reliable air in an energy efficient package. By installing an Engineered Air HR Externally Heated or HB Blower Purge dryer Eliminate Water from Your Compressed Air System In today s competitive industrial markets, dry compressed air is a necessity not a luxury. The Engineered Air Products Genesis Series of Heat Reactivated compressed air dryers the user will see immediate results in the removal of moisture and contaminants from their system. While there are many different applications where heated desiccant dryers apply, no two applications are exactly alike. Upon installation, there are a number of variables within the operating environment where the dryer may be located. Through EAP s exclusive process of Tuned Regeneration, the user can dovetail the dryer regeneration process to achieve optimal results. Overall KW reduction and alleviation of dew point bumps can be realized through a process of tuning the interactive settings in the Logic Pro Master Controller. Understanding the Master Controller is so easy, most users are comfortable with system operation after only a few minutes of interaction. Because the EAP heated dryer is provided with three independent Genesis Heated Dryers readouts, the user can quickly see the heating pattern of the regeneration tower. Adjustments to heating temperature, duration and cycling controls can all be made without the need for costly programming. Slight adjustments from winter to summer months can result in maintaining system peak operational efficiency, while reducing energy usage. Adjustments of cooling cycles can reduce dew point spikes and maximize air volume available to process.

3 EAP Genesis heat reactivated desiccant dryers use the adsorption method to remove saturated compressed air flows through the drying tower, its moisture content adheres to the surface System Flow Schematics moisture from compressed air. Pressure dew points of minus 40 0 F/C to as low as F (-56 0 C) are achieved by directing the flow of saturated compressed air over a bed of desiccant. As the of the desiccant, resulting in reduced relative humidity and optimal dew points. The dried process air is final polished by micron filter and sent to the plant air distribution system. In order to fully and effectively regenerate the off line saturated tower of the HR series, EAP utilizes the most advanced and highly tuned procedure in the industry. A regulated amount of already dried process air (approx. 7%) is heated by way of a low watt density heater and passed down (counter current) through the desiccant bed. This heated purge air, exhausted to atmosphere, removes all of the collected moisture adhered to the desiccant from the previous drying cycle. Air Out Air Out HR Regeneration Pre Exhaust Valve Main Exhaust Valve Inlet Valve HB Regeneration Air In Air In Pre Exhaust Valve Main Exhaust Valve Inlet Valve The EAP HB series of dryers also use heated air to regenerate the off line tower, however no process air is used during regeneration. A high efficiency packaged blower assembly directs heated atmospheric air counter current through the desiccant bed, removing all of the moisture that was collected during the previous drying cycle. Dew point spikes or heat bump can be minimized by tuning the regeneration cycle to meet the application. Energy (KW) requirements are greatly reduced through the use of our exhaust system temperature controllers. HR & HB Features Upon achievement of optimal temperatures in the regenerating tower, the heater system is turned off and the tower is cooled in preparation for its return to the drying process. Cooling and dry purge cycles can be customized to provide the best regeneration results. All EAP heated Dryers are equipped with fail-safe and heat-safe directional valves. Should there be a power failure or emergency stop, the inlet air directional system will maintain its exact position, locking out the regeneration tower. This protects the user from allowing excessive heated purge to enter the distribution system, which can affect process and damage downstream pneumatic devices. Upon restoration of power, the retentive memory systematically steps the dryer back into process condition without interaction from the user, and without affecting the duration of the current regeneration.

4 With a combination of quality name brand components, superior craftsmanship and a software package delivering on EAP s many years of experience, Logic Pro represents a revolution in simplifying dryer control. Logic Pro Master Controllers All EAP dryers capitalize on the superior performance of Allen-Bradley PLC Controllers. Allen-Bradley controllers are established as highly reliable, repeatable, and expandable, and are common within industrial controls environments. There is no need to open the control panel or access any internal working components of the control box. All functions are easily managed and displayed on the 4 inch interactive touchscreen controls. A 6 inch touch screen is standard on 4000 SCFM and larger dryers Chances are, when you purchase an EAP heated dryer, your facility operations team is likely familiar with our controls platform already. Primary Voltage Control Box Lockable, gasketed NEMA enclosures Service disconnect switch Single point connections Dual contactors for heater control Primary cycling contactor controls heater operation Secondary over-temperature contactor protects circuit Redundant contactors provide the ultimate in heater system protection Built-in fused secondary voltage transformer Blower overload protection and motor starters User Interface / Low Voltage Control Box Interactive control system with visual indication of current condition Run/Standby Mode Heatless Back Up Mode Cycle Stepping Service programming menus allow user to dovetail operational set points Temperature indication package with digital display and alarm Exhaust Temperature Monitors (Saves Energy) Full compliement of pressure, temperature, and alarm readouts EcoTronic Dew Point Control (Optional) Digital Dew Point Readout High Humidity Alarm Communications through Allen Bradley Controller Emergency Stop Durable NEMA 4 sheet metal cabinet All Components independently fused to UL and CSA standards

5 6 Touch Screen 4 Touch Screen Allen Bradley with Interactive Menu Search Full on-board temperature and pressure menu with interactive set points and alarms Retentive alarm log with fault code readout and time stamping Communications package for remote monitoring (MODBUS RTU Standard, other languages available, consult factory) Step by step countdown timers for all operations Interactive service menu allowing direct control of parameters Available Options Ecotronic Demand Control All EAP dryers equipped with the Logic Pro Heated Dryer Controller are pre programed to accept the 4-0mA loop from the Ecotronic moisture analyzer probe. The Ecotronic provides numerous benefits over a system that operates exclusively on an 8 hour NEMA cycle. Demand Cycle Operation Unit only switches when the dew point achieves user desired set point (factory set at F/C). Significant energy savings are realized by reduction of blower and heater KW consumption and purge. Digital Dew Point Readout High Humidity Alarm with Output 4-0 ma Output Standard Unit continuously displays outlet dew point quality of air, and is visible on all menu screens. High dew point alarm is adjustable and alarm light is displayed on main menu should upset condition occur. The significance of protecting a desiccant dryer system with suitable filtration cannot be understated. If incoming air is not filtered of oils, liquids Packaged Filters - Complete Air Treatment System and aerosols, contamination of the desiccant material will occur, leading to an eventual system failure. To keep your system operating at peak efficiency, Engineered Air Products recommends factory installed filtration systems, designed and matched directly to the dryer. The resulting package reflects a complete air treatment system which provides easier installation, single point connections and data acquisition functions from a single Logic Pro control system. All EAP Heat Reactivated Air Dryers come complete with the pre and after filters mounted and piped to match the dryer. The 0.0 micron coalescing pre filter (equipped with and auto drain/isolation service valve) and pressure differential indicator, ensures that oil aerosols and bulk liquids do not enter the inlet flow and contaminate the desiccant bed. The micron particulate after-filter will remove any solids for truly polished and ultra clean, dry compressed air. Depending on your application, EAP can supply an assortment of filter configurations to suit your specific needs.

6 EAP dryers are provided with our advanced software package that allows the operations engineer to dovetail dryer operating set points to actual operating Interactive Allen Bradley Controllers conditions. The ability to make fine adjustments to dryer operations in the field ensures the highest quality air to process, while reducing service and maintenance costs. All EAP HR and HB dryers are constructed using premium actuated positioning valves to direct the inlet flow of compressed air. Premium Non-Lubricated Rotary Actuated Valves The inlet directional valves are dual acting to assure proper air flow and continued operation even in a system fault condition or power outage. These premium valves are so reliable they carry a 3 year factory warranty. EAP dryers exclusively use high quality USA manufactured activated alumina desiccants. These desiccants have a high surface to mass ratio, high crush strength and are Premium Quality Desiccants designed specifically for air dehydration applications. For systems requiring extremely low dew points, EAP offers Molecular sieve as a polishing layer in combination with an alumina base layer. Standard Through the use of EAP s exclusive and patent pending process of Tuned Regeneration, the HR and HB heated dryers use only the energy required to provide a gentle and Premium Non-Lubricated Rotary Actuated Valves consistent low pressure air-flow to desorb the accumulated moisture from the regeneration tower. Continuous exhaust air temperature monitoring further reduces energy consumption by controlling heating cycle duration on demand. Equipment Touch Screen Interactive Display Screen ASME/CRN Code Pressure Vessels Logic Pro Advanced Control System Field Adjustable Operating Parameters System Run/Standby Selector Switch Emergency Stop Button and Alarm Premium Inlet Switching Valves with 3 Year Warranty Separate High and Low Voltage Control Boxes with Single Point Power Connections Tri-temp Heater Control System Heater Protection Over-Temperature Shut Down with Alarm Low Watt Density Heaters Exhaust Temperature Monitors w/ Early Heat Temperature Feature Tuned Regeneration Temperature Control with Dual Contactors CRN/CSA approvals for Canada (Consult factory for details) Industrial Duty Blower (HB Only) Control Air Regulating Valve with Gauge and Orifice Union Control Air Filter F Pressure Dew Point Standard Adjustable/Selectable % Stripping Cycle (HB Only) Heatless Back-Up Mode Re-Pressurization Circuit Premium Directional Purge, Outlet and Blower Check Valves Rated for High Temperature Service Premium High Temperature Exhaust Valves Premium USA activated Alumina Desiccant Full Flow Safety Relief Valves Heater Circuit Insulation and Aluminum Jacketing Communication Packages for Remote Monitoring Premium Stainless Steel Bezel Pressure Gauges Tower Moisture Indicators Structural Steel Skids Equipment Lifting Lugs Mounted Filters Optional Filter Packages System Bypass Packages (All) EcoTronic Demand Control Tower Insulation Outdoor Jacketing of Insulation Low Flow Alarm Switch Failure Alarm Special Voltage Low Ambient Insulation with Heat Tracing Stainless steel control tubing Special Options All Welded Construction Extra Heavy, Non-Yellow Metal Construction Full Base Top Plate or Diamond Plate

7 Model 00 PSIG Line Size (Inches) Electrics Max Heater KW Approx Purge (SCFM) Dimensions W x D x H (Inches) Unit Weight (lbs) HR00 HR30 HR00 HR300 HR400 HR550 HR650 HR800 HR000 HR50 HR500 HR000 HR600 HR3000 HR4000 HR5000 HR / / 4FL 4FL 5V/ 5V/ 5V/ x 4 x x 4 x x 4 x x 46 x x 46 x x 50 x x 50 x x 60 x x 60 x x 80 x 0 80 x 80 x 90 x 95 x x 05 x 05 3 x 0 x 05 3 x 80(46) x ,90,35,950,5 3,60 4,400 5,50 6,360 7,800 9,800,50 3,080 Dryer Specifications Model 00 PSIG Line Size (Inches) Electrics Max Heater KW Blower HorsePower Dimensions W x D x H (Inches) Unit Weight (lbs) HB V/.3 46 x 4 x HB00 00 / x 4 x HB / x 46 x HB x 46 x 98,480 HB x 50 x 98,30 HB x 50 x 98,450 HB x 60 x 00 3,580 HB x 60 x 06 4,850 HB x 80 x 0,750 HB x 80 x 6,900 HB x 95 x 05 8,600 HB FL x 05 x 05 0,750 HB FL x 0 x 05,960 HB x 80(46) x 06 4,50 * Consult Factory HB All specifications and dimensions subject to change without notice. All units 00 SCFM and larger available with 575/3/60 electrical supply. HB Unites 4000 SCFM and larger with factory packaged filters are provided on two bases designed to bolt together at installation. Correction factor for inlet air pressure (PSIG) Correction factor for inlet temperature 0 F Capacity Correction Factors C Factor Corrected flow = Normal capacity of dryer (SCFM) x inlet pressure factor x inlet temperature factor

8 Engineered Air Products ph fax Patents Pending Made in 04 Engineered Air Products, Lancaster, NY 4086 HBHL

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com PNEUMATIC PRODUCTS pneumaticproducts-spx.com Externally Heated Desiccant Compressed Air Dryers PHD Series PHD Series Dryers Reduce Purge Air Energy Costs PHD Series Dryers Reduce Purge Air Energy Costs

More information

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration INNOVATIVE COMPRESSED AIR SOLUTIONS DESICCANT AIR DRYERS 90-8000 scfm ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration 2100ZHA RELIABLE PERFORMANCE INNOVATIVE DESIGN Before

More information

Desiccant Air Dryers Heatless, Heated and Heated Blower

Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... Desiccant Our reliable high strength, non-acidic desiccant provides maximum performance and is easily stored and handled. Environmentally

More information

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION 2099 Ninth Avenue Ronkonkoma, NY 11779 www.vacuuminst.com Smart Charge II An advanced gas backfill and evacuation system with built-in gross leak test.

More information

Ingersoll Rand. Heat-Of-Compression Air Dryers

Ingersoll Rand. Heat-Of-Compression Air Dryers Heat-Of-Compression Air Dryers Air Quality Solutions by Heat-of-compression (HOC) dryers are dual-tower, desiccant designs. The HOC dryer is the most energy-efficient dryer available. It recovers the heat

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER

BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER quincycompressor.com 701 North Dobson Avenue Bay Minette, AL 36507 Phone: 251.937.5900 Fax: 251.937-1457 BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER 1. SCOPE The specification outlines

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance (200-1000 scfm models)

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance (200-1000 scfm models) INNOVATIVE COMPRESSE AIR SOLUTIONS COMPRESSE AIR SOLUTIONS eatsink TRUE-CYCLING REFRIGERATE COMPRESSE AIR RYERS 150 2,400 SCFM Independently Verified Performance (200-1000 scfm models) Stainless Steel

More information

REFRIGERATED COMPRESSED AIR DRYERS

REFRIGERATED COMPRESSED AIR DRYERS INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING OPERATION 75 2,400 scfm Capacity Models STAINLESS STEEL HEAT EXCHANGERS www.zeks.com Compressed

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS Value and Performance Through Advanced Technology ABOUT PNEUMATIC PRODUCTS PPC s Heritage Since 1946, PPC has been recognized

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges

More information

DHA & DBA Series. Heat Reactivated Desiccant Dryers

DHA & DBA Series. Heat Reactivated Desiccant Dryers DHA & DBA Series Heat Reactivated Desiccant Dryers 02 12 DHA & DBA series externally heated and blower purge desiccant air dryers Parker domnick hunter Externally Heated and Blower Purge Desiccant Air

More information

D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00

D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00 SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical

More information

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer Why drying compressed air? Compressed air is used in almost all areas of industrial manufacturing as a source of energy or processing. Compressed air needs to be dry, oilfree and clean in order to prevent

More information

Compressed Air and Gas Drying

Compressed Air and Gas Drying Compressed Air and Gas Drying CONTENTS I. Why Do Compressed Air And Gas Need Drying? 1 II. Applications Requiring Clean, Dry Air 1 III. How To Measure Moisture Content 2 IV. Selecting The Right Dryer 3

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

Sigma Frequency Control

Sigma Frequency Control Sigma Frequency Control SFC Series 18 to 515 Capacities: from 22 to 3069 cfm Pressures: from 80 to 217 psig Variable Speed Technology from Kaeser Most compressed air systems have varying loads and it is

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

Commercial Boiler Systems and Controls

Commercial Boiler Systems and Controls Commercial Boiler Systems and Controls Condensing Non-condensing Hybrid Systems Steel Medium Mass Copper Instantaneous Electric Riverside R HYDRONICS An introduction to hybrid boiler systems What is a

More information

Meeting Your Compressed Air Treatment Needs

Meeting Your Compressed Air Treatment Needs Compressed Air Treatment Guide Meeting Your Compressed Air Treatment Needs How to Select the Right Equipment for Your Application Provided as a Service by Kaeser Compressors, Inc. Typical Air Treatment

More information

Pro Dry Heatless dessiccant compressed air dryers

Pro Dry Heatless dessiccant compressed air dryers Pro Dry Heatless dessiccant compressed air dryers Features Each Pro Dry unit has been designed to suit a multitude of requirements and is suitable for installation in many countries. The Pro Dry range

More information

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

How To Control A Medical Device With A Pc System

How To Control A Medical Device With A Pc System Clean room monitoring and disinfection FMS 5.0, the Leading Facility Monitoring Software TSI FMS system is an advanced, reliable, and user-friendly monitoring software suite that features a truly open

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 Refrigerated D r y A i r T e c h n o l o g y b y A r r o w P n e u m a t i c s red C. Gilbert Co. 10 Norris Road akersfield, Ca. 908 1-99-959 fax 1-9-95 Q u a l i t y A i r P r e p a r a t i o n E q u

More information

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR Atlas Copco Compressed air dryers CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR Why Quality Air? When the air that surrounds us is compressed, its vapour and particle concentration increases

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

Automatic Self-Cleaning Strainers

Automatic Self-Cleaning Strainers Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning

More information

Commercial Electric Water Heater

Commercial Electric Water Heater MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining

More information

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Laboratory & Scientific Line. Horizontal Steam Sterilizers Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

Efficient and reliable fans, compressors and blowers

Efficient and reliable fans, compressors and blowers Efficient and reliable fans, compressors and blowers Reliable operation p rotects your process Reliable operation Energy savings Low operating cost Extended equipment lifetime Would you like to protect

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400 Technical ata Sheet Page 1 of 6 igh Pressure ryer -MS 0055 to 0870, PN 100 to PN 400 igh pressure adsorption dryer, heatless regenerating, pre-, and afterfilter included Compressed air is lead through

More information

ultrafilter HEATLESS HL Adsorption Dryer

ultrafilter HEATLESS HL Adsorption Dryer The EW product line of HeatLess adsorption dryers Why drying compressed air? Compressed air is used in almost all areas of industrial manufacturing as a source of energy or processing. Compressed air needs

More information

ice 3 FLUID TO FLUID HEAT PUMP

ice 3 FLUID TO FLUID HEAT PUMP ice 3 FLUID TO FLUID HEAT PUMP SUBMITTAL DATA (888) 530-7713 P O Box 5, Wentworth, H 03282 Rev.3 (5-30-14) ice 3, IC-2040 Fluid-to-Fluid R-410a Heat Pump Engineering Guide Specifications General otes:

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction

More information

Air Dryer Application Guidelines

Air Dryer Application Guidelines $2.50 Air Dryer Application Guidelines TP-9672 Revised 11-98 System Saver 1000 and 1200 Series System Saver TWIN Table of Contents Introduction Purpose of This Guide.................................................................

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

HEAVY WATER LEAK DETECTOR

HEAVY WATER LEAK DETECTOR HEAVY WATER LEAK DETECTOR WEB www.overhoff.com MODEL 1925 HEAVY WATER LEAK DETECTOR (HWLD) LOW LEVEL REAL TIME TRITIUM-IN-WATER MONITOR This monitor has been designed for real time low-level detection

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN Application 1 The first step in selecting an industrial oven is defining the required heat application that your oven will be used for. Heat processing is extensively

More information