The PSAX 4500 Alarm module is illustrated in Figure 1. Figure 1. PSAX 4500 Alarm Module. COMCODE Software Release Model Faceplate Label

Size: px
Start display at page:

Download "The PSAX 4500 Alarm module is illustrated in Figure 1. Figure 1. PSAX 4500 Alarm Module. COMCODE Software Release Model Faceplate Label"

Transcription

1 PSAX 4500 Alarm Module Description and Specifications Model 45N79 Purpose of This Document This document identifies and describes the PSAX 4500 Alarm module and related safety information. It also includes procedures for installation and removal of the module from the PSAX chassis and verification of the initial module startup, as well as information on obtaining troubleshooting assistance. Regulatory standards compliance is also described for the module. Identifying the Module The PSAX 4500 Alarm module is illustrated in Figure 1. ALARM CRITICAL MAJOR MINOR ACO STATUS/CONTROL ALARM Figure 1. PSAX 4500 Alarm Module The PSAX 4500 Alarm module has been tested and verified by Lucent Technologies to operate with the following PSAX Central Office (CO) software versions. COMCODE Software Release Model Faceplate Label V07.01.C01 45N79 ALARM and subsequent PSAX 4500 Alarm Module Description and Specifications Page 1 of 18 Part Number: 561M0A0001Z2 Document Number:

2 Safety Information When installing and operating the PSAX 4500 Alarm module, follow the safety guidelines provided in the PacketStar PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the module. Please read all warnings and instructions supplied before beginning installation or configuration of the module. In addition to the general safety information provided, you should also refer to the PacketStar PSAX 4500 Alarm Module User Guide for other important safety information and procedures. Hardware Features Supported The PSAX 4500 Alarm module supports all hardware releases and features of the PSAX 4500 system. Hardware Description Hardware Features The PSAX 4500 Alarm module provides the following connectors and indicators to interface with the CO personnel, sensors, external controls, and alarms: Number of connectors: 2 Connector type: ~ one HD-22, 26-pin ALARM connector provides alarm output and remote alarm cutoff (ACO) input connections ~ one HD-22, 44-pin STATUS/CONTROL connector provides external sensor input and remote control output connections Inputs: 15 opto-isolators to monitor external sensor inputs and 1 opto-isolator for remote ACO control devices. Outputs: 10 relays with Form 1-C contacts (NO/NC/COM connections), 4 relays to control remote devices and 3 audible and 3 visible relays for external alarm generation Indicators: 4 LEDs, 3 for alarm conditions (Critical, Major, and Minor) and 1 LED for the ACO switch operation. Module Placement The PSAX 4500 Alarm module is only installed in slot 14 of the PSAX 4500 rear panel. Do not attempt to install the Alarm module (model 20N79) in slot 14 on the front panel when the PSAX 4500 Alarm module is installed. Any PSAX I/O module, except the Alarm module (model 20N79), can be inserted in slot 14 opposite the rear-mounted PSAX 4500 Alarm module without impacting traffic.! WARNING: Do not attempt to use the PSAX 4500 Alarm module (model 45N79) and Alarm module (model 20N79) in the PSAX 4500 chassis at the same time. Unpredictable results and damage to the modules will occur. Page 2 of 18 PSAX 4500 Alarm Module Description and Specifications

3 Hardware Specifications Table 1 shows the physical and environmental hardware specifications for the PSAX 4500 Alarm module. Table 1. Physical Hardware Specifications for the PSAX 4500 Alarm Module Specification Dimensions Weight Maximum Relay and Sensor Power Alarm and Output Control Relays Remote status inputs and remote ACO input Description 27.4 cm H x 2.4 cm W x 12.2 cm D (10.8 in. H x 0.95 in. W x 4.8 in. D) 270 g (0.6 lb.) 1 A at 48 V dc typical, 60 W maximum, 2 A dc maximum Form 1-C contacts (NC/NO/COM) Opto-isolators (IN/COM) for dry contact * relays Environmental Operating temperature range: 0 to 50 C (32 to 122 F) Operating humidity range: 5% to 85% relative humidity Operating altitude range: 60 meters (197 feet) below sea level to 4,000 meters (13,123 feet) above sea level Storage temperature range: -40 to 70 C (-40 to 158 F) Storage humidity range: 0% to 90% noncondensing * A dry contact is a relay contact that does not cause a spark that damages the contacts when they open and close. This is usually done by placing a resistive component, like another relay, between the relay contacts and the voltage source. Power Consumption Table 2 provides the chassis speed, power consumption, and memory allocation specifications for this PSAX module. Table 2. Performance and Power Specifications for the PSAX Module Module 45N79 PSAX 4500 Alarm Total Amount of SDRAM Module Program and Data Space Maximum Input Buffer Output Buffer Chassis Speed Maximum Power Consumption N/A N/A N/A N/A N/A 3 W Connector Configurations This information describes the pin locations and pin assignments on the ALARM and STATUS/CONTROL connectors. It also includes information on two orderable cables used to connect the PSAX 4500 Alarm module to the facility alarm and control systems. ALARM Connector and Cable Figure 2 illustrates the pin locations of the 26-pin ALARM connector on the PSAX 4500 Alarm module (model 45N79) faceplate. Note: The PSAX 4500 Alarm module ALARM connector is rotated 180 from the Alarm module ALARM connector. PSAX 4500 Alarm Module Description and Specifications Page 3 of 18

4 Pin Pin 10 Pin Pin 26 Pin 9 Pin 18 Figure 2. ALARM Connector Pin Locations on the PSAX 4500 Alarm Module A shielded 3.7-meter (12-foot) Lucent cable (Part Number 42-20N79004, COM- CODE ) is available with a matching connector on one end and a 16-pair twisted wire pigtail on the other end (see Figure 3). Figure 3. ALARM Cable with 26-Pin Connector and Pigtail The pin assignments for the ALARM connector and the shielded Lucent cable pigtail color code are described in Table 3. Table 3. ALARM Connector Pin Assignments and Cable Pigtail Color Code (COMCODE ) Connector Pin Description Cable Pigtail Color Code * 2 Audible Critical Alarm COM contact White/Brown 13 Audible Critical Alarm NC contact White/Violet 1 Audible Critical Alarm NO contact White/Tan 4 Audible Major Alarm COM contact White/Pink 14 Audible Major Alarm NC contact White/Gray 3 Audible Major Alarm NO contact Brown/White 6 Audible Minor Alarm COM contact White/Orange 15 Audible Minor Alarm NC contact Tan/Brown 5 Audible Minor Alarm NO contact Pink/White 20 Battery Return ** Orange/Tan 26 Frame Ground Yellow/Tan 24 Remote Alarm Cutoff Battery Return Pink/Tan Page 4 of 18 PSAX 4500 Alarm Module Description and Specifications

5 Table 3. ALARM Connector Pin Assignments and Cable Pigtail Color Code (COMCODE ) (Continued) Connector Pin Description Cable Pigtail Color Code * 23 Remote Alarm Cutoff input Brown/Tan 19 Unused Tan/Orange 21 Unused Violet/White 22 Unused Gray/White 25 Unused Tan/Yellow 8 Visible Critical Alarm COM contact White/Yellow 16 Visible Critical Alarm NC contact Tan/Pink 7 Visible Critical Alarm NO contact Orange/White 10 Visible Major Alarm COM contact Tan/White 17 Visible Major Alarm NC contact Yellow/White 9 Visible Major Alarm NO contact White/Green 12 Visible Minor Alarm COM contact Blue/White 18 Visible Minor Alarm NC contact Green/White 11 Visible Minor Alarm NO contact White/Blue * Color code subject to change without notice. COM is common relay contact between NC and NO contacts. Audible and visible critical alarm relays are shown normally energized when no alarm is being generated. A critical alarm is generated through a command that de-energizes the relay or when power is lost. NC is normally closed relay contact. NO is normally open relay contact. ** Battery Return is used typically for -48 V dc operation. Contact closure or input command is sensed by opto-isolator. STATUS/CONTROL Connector Figure 4 illustrates the pin locations of the 44-pin STATUS/CONTROL connector on the module faceplate. STATUS/CONTROL Pin 1 Figure 4. STATUS/CONTROL Connector Pin Locations on the PSAX 4500 Alarm Module PSAX 4500 Alarm Module Description and Specifications Page 5 of 18

6 Note: The PSAX 4500 Alarm module STATUS/CONTROL connector is rotated 180 from the Alarm module STATUS/CONTROL connector. A shielded 3.7-meter (12-foot) Lucent cable (Part Number 42-20N79003, COM- CODE ) is available with a matching connector on one end and a 25-pair twisted pair pigtail on the other end (see Figure 5). Figure 5. STATUS/CONTROL Cable with 44-Pin Connector and Pigtail The pin assignments for the STATUS/CONTROL connector and the shielded Lucent cable pigtail color code are described in Table 4. Table 4. STATUS/CONTROL Connector Pin Assignments and Cable Pigtail Color Code (COMCODE ) Connector Pin Description Cable Pigtail Color Code * 43 Battery Return Brown/Blue 32 Control Output 1 COM contact Violet/Tan 33 Control Output 1 NC contact Tan/Gray 31 Control Output 1 NO contact Tan/Violet 36 Control Output 2 COM contact Pink/Brown 34 Control Output 2 NC contact Gray/Tan 35 Control Output 2 NO contact Brown/Pink 38 Control Output 3 COM contact Orange/Brown 39 Control Output 3 NC contact Brown/Yellow 37 Control Output 3 NO contact Brown/Orange 42 Control Output 4 COM contact Green/Brown 40 Control Output 4 NC contact Yellow/Brown 41 Control Output 4 NO contact Brown/Green 44 Frame Ground Blue/Brown 1 Status Input 01 White/Tan 2 Battery Return Tan/White 3 Status Input 02 White/Brown 4 Battery Return Brown/White 5 Status Input 03 White/Pink 6 Battery Return Pink/White 7 Status Input 04 White/Orange 8 Battery Return Orange/White 9 Status Input 05 White/Yellow 10 Battery Return Yellow/White Page 6 of 18 PSAX 4500 Alarm Module Description and Specifications

7 Table 4. STATUS/CONTROL Connector Pin Assignments and Cable Pigtail Color Code (COMCODE ) (Continued) Connector Pin Description Cable Pigtail Color Code * 11 Status Input 06 White/Green 12 Battery Return Green/White 13 Status Input 07 White/Blue 14 Battery Return Blue/White 15 Status Input 08 White/Violet 16 Battery Return Violet/White 17 Status Input 09 White/Gray 18 Battery Return Gray/White 19 Status Input 10 Tan/Brown 20 Battery Return Brown/Tan 21 Status Input 11 Tan/Pink 22 Battery Return Pink/Tan 23 Status Input 12 Tan/Orange 24 Battery Return Orange/Tan 25 Status Input 13 Tan/Yellow 26 Battery Return Yellow/Tan 27 Status Input 14 Tan/Green 28 Battery Return Green/Tan 29 Status Input 15 Tan/Blue 30 Battery Return Blue/Tan * Color code subject to change without notice. NC is normally closed relay contact. NO is normally open relay contact. Shown in a normally energized state. A control command or loss of power changes the relay contact state. Battery Return is used typically for -48 V dc operation. Functional Description The PSAX 4500 Alarm module provides two connectors that allow for connections with external facility sensor inputs (doors, temperature, and so on), chassis alarm outputs (visible and audible), external device controls (cooling, heating, doors, and so on), and audible alarm cutoff controls (see Figure 6). In addition, the CPUn module generates trap messages that reflect state changes of the PSAX 4500 Alarm module s sensor inputs, control outputs, and alarm cutoff control. PSAX 4500 Alarm Module Description and Specifications Page 7 of 18

8 Critical Major Minor ALARM CRITICAL MAJOR CO Alarms MINOR ACO Alarms STATUS/CONTROL ALARM Output Input Hot Fan Temp. Sensor Cold Figure 6. Example Configuration with the PSAX 4500 Alarm Module The PSAX 4500 Alarm module is functionally identical to the Alarm module (model 20N79), but the module is designed to be mounted only in the rear panel (slot 14) of the PSAX 4500 chassis. This enables you to make maximum use of the front panel I/O slots. The module uses midplane bus traces that do not impact midplane bus utilization calculations. Like all of the other PSAX modules, the PSAX 4500 Alarm module is monitored and controlled through the console or EMS-PSAX. For a detailed description of the PSAX 4500 Alarm module, see the PacketStar PSAX 4500 Alarm Module User Guide. Alarm Outputs Alarm Severity Levels The PSAX 4500 Alarm module provides three severity levels of alarms Critical, Major, and Minor as reported by the following devices: LEDs on the module faceplate and chassis front panel Relay contact closures that activate external audible and visible alarms in the CO or NOC SNMP trap messages Visible alarms assist in identifying and locating the particular chassis that is in an alarm condition by activating the equipment bay alarm lights and chassis alarm indicators. Audible alarms also occur when an alarm condition exists in the CO or switch room. Alarms reported at each of the three severity levels Critical, Major, and Minor are interdependent. If a higher severity alarm condition occurs (such as Critical during the presence of a lower severity alarm (such as Minor), the Critical alarms (LEDs, visible, and audible) are activated and the Minor alarms are temporarily deactivated. Once the condition causing the higher severity alarm is cleared, the Critical alarms are deactivated, or cleared, and the Minor alarms are reactivated (if applicable). Page 8 of 18 PSAX 4500 Alarm Module Description and Specifications

9 Output Generation Criteria The generated alarms described in Table 5 occur under the following conditions: Table 5. Module Alarm Generation Criteria This Alarm occurs Under the following conditions CRITICAL MAJOR MINOR Loss of input power to the chassis all module LEDs do not illuminate but a Critical alarm is generated when the alarm relay becomes unpowered and causes the relay contacts to change position Failure of both CPUn modules Loss or Failure of both Stratum 3 4 modules Loss of both BITS clocks Loss of both Composite clocks Loss of both primary and secondary I/O timing references (if provisioned) Failure of one -48 V dc Power Supply module (including fan) Loss of one BITS or Composite clock timing reference source Failure of one Stratum 3 4 module in a redundant configuration Failure of one CPUn module in a redundant configuration Failure of one configured module Loss of signal or frame from a primary or secondary timing source when line timing is configured on the Stratum 3 4 module When more than one of the above conditions occurs in more than one category, the highest severity alarm determines which LED illuminates. Note: Output contact closures are not supported for a non-redundant Stratum 3 4 module configuration as this results in a permanent Minor alarm. Alarm Relay Operation The activation of the external alarms in the CO is controlled through six relays (three for visible alarms and three for audible alarms) with Form 1-C contacts (see Figure 7). The contacts normally open (NO), normally closed (NC), and common (COM) are accessible through the ALARM connector. PSAX 4500 Alarm Module Description and Specifications Page 9 of 18

10 ALARM Connector 26-pin 1 NO 2 COM 13 NC 3 NO 4 COM 14 NC Audible Alarm Critical (Normally Energized No Alarm) Audible Alarm Major -OR- 1 NC 2 COM 13 NO Audible Alarm Critical (Power Lost Alarm Generated) 5 NO 6 COM 15 NC Audible Alarm Minor 7 NO 8 COM 16 NC 9 NO 10 COM 17 NC Visible Alarm Critical (Normally Energized No Alarm) Visible Alarm Major -OR- 7 NC 8 COM 16 NO Visible Alarm Critical (Power Lost Alarm Generated) 11 NO 12 COM 18 NC Visible Alarm Minor 20 +BAT RTN Vdc 23 IN GND +BAT RTN -BAT (-48Vdc) Remote Alarm Cutoff Not Used NO - Normally Open NC - Normally Closed COM - Common BAT RTN - Battery Return Figure 7. ALARM Connector Configuration To allow flexibility in connecting the module to the external alarm panel: The Major and Minor alarm relays are energized only when an appropriate alarm condition occurs. The Critical alarm relays are normally energized when no alarms are reported. When a Critical alarm is reported or power fails, the relays are de-energized, causing contacts to change positions and in turn causing the CO alarms to be activated. Figure 8 illustrates how the PSAX 4500 Alarm module might be connected to a CO alarm panel. Diagram A shows an unalarmed condition. Diagram B shows an alarmed condition. Page 10 of 18 PSAX 4500 Alarm Module Description and Specifications

11 A No Alarms Critical Major Minor PSAX Alarm Module Alarms 9 NO 10 COM 17 NC Major Alarm Visible Alarm Panel B Major Alarm Generated Critical Major Minor PSAX Alarm Module Alarms 9 NO 10 COM 17 NC Major Alarm Generated Alarm Panel NO - Normally Open NC - Normally Closed COM - Common Figure 8. Generating Alarms Audible Alarm Cutoff (ACO) The alarm cutoff (ACO) function provides a method of silencing the audible alarms caused by an alarm condition being reported by the chassis; it has no effect on the visible alarms activated by the module. The alarm cutoff is controlled through the ACO switch on the module and from a remote ACO device (connected through the ALARM connector). A remote ACO device could be a switch, relay contacts, or software command. When an audible alarm occurs, pressing the module ACO switch or activating the remote ACO device once performs the following functions: Silences the audible alarms, but does not clear the alarm condition Illuminates the yellow ACO LED on the module Reports the change in state to the CPUn module Pressing the module ACO switch or deactivating the remote ACO device a second time performs the following functions: Reestablishes the audible alarm functionality Extinguishes the yellow ACO LED on the module Reports the change in state to the CPUn module PSAX 4500 Alarm Module Description and Specifications Page 11 of 18

12 The local and remote alarm cutoffs operate independently of each other. This change in state (on to off, off to on) is also shown in the Audible Alarm Status panel of the console Alarm Configuration window. Control Outputs The PSAX 4500 Alarm module can control up to four remotely controlled devices, such as air conditioning, heating, lighting, and so on, through four relays. The relays are controlled through the Control Outputs panel on the Alarm Module Configuration window. The Control Output relays have Form 1-C contacts (normally open (NO), normally closed (NC), and common (COM)) that are accessible through the STA- TUS/CONTROL connector (see Figure 9). The contact configuration allows flexibility in connecting the module to remotely controlled devices. Control Output relays 1, 2, and 3 are normally in an off state (COM and NC contacts closed) when no command is sent. They are energized (changed from a normal off state to an on state) only when a control command is sent. Control Output relay 4 is normally energized (COM and NO contacts closed) when no command is sent. When a control command is sent, the relay is not energized causing the COM and NC contacts to close and in turn causing the external device to be activated or deactivated. STATUS/CONTROL Connector 44-pin Opto-Isolator Vdc 1 IN 2 Status Input IN 30 +BAT RTN -BAT (-48Vdc) Vdc Status Input NO 32 COM 33 NC Control Output 1 +BAT RTN -BAT (-48Vdc) 34 NO 35 COM 36 NC Control Output 2 37 NO 38 COM 39 NC Control Output 3 41 NO 42 COM 40 NC (Relay Normally Energized) -OR- 41 NC 42 COM 40 NO Control Output 4 (Power Lost) +BAT RTN (GND) GND NO - Normally Open NC - Normally Closed COM - Common BAT RTN - Battery Return Figure 9. Control Output Relay Configuration Page 12 of 18 PSAX 4500 Alarm Module Description and Specifications

13 Figure 10 shows how the module activates a Control Output relay to activate the supplemental air conditioning. The command maintains the contact closure for 30 seconds, which means the remote device must have the capability of sustaining itself until the situation resolves itself, such as when the air temperature returns to normal. PSAX Alarm Module AC Off Control Output 1 (AC Off) PSAX Alarm Module AC On Control Output 2 (AC On) Figure 10. Activating Supplemental Air Conditioning Remote Status Inputs Fifteen remote status inputs are provided through the STATUS/CONTROL connector to enable remote sensors to be monitored and reported to the NOC. Opto-isolators are used to monitor the opening and closing of dry contact relays in devices that can report their own operational status. An input and common connection is provided for each opto-isolator. An example of a remote sensor would be a door sensor that indicates whether the door is open or closed as shown in Figure 11. PSAX Alarm Module Status/ Control Door Sensor N 1 2 IN Status Input 1 (Door Closed) -BAT (-48Vdc) +BAT RTN Figure 11. Monitoring and Reporting on Door Sensors PSAX 4500 Alarm Module Description and Specifications Page 13 of 18

14 Required Components to Install the Module The PSAX 4500 Alarm module is only installed in slot 14 of the rear panel of the chassis. For newer models of the PSAX 4500 chassis, the individual blank faceplates are installed at the factory. For older PSAX 4500 chassis with the single blank panel covering the rear of the chassis, the PSAX 4500 Rear Blank Faceplate Kit (model 45N85, COMCODE ) must be ordered. For ordering information, contact your Lucent Technologies account manager. The PSAX 4500 Rear Blank Faceplate Kit includes the following rear panel blank faceplates (see Figure 12): Four LIM3 4 Single-Slot Blank Faceplates Two LIM3 4 Double-Slot Blank Faceplates Three LIM3 4 Triple-Slot Blank Faceplates One Stratum 3 4 Double-Slot Blank Faceplate This kit provides the necessary blank faceplates for all rear panel configurations S T R A T U M BA Slot 2-Slot Blank Faceplate 3-Slot Figure 12. Standard Rear Panel Blank Faceplate Kit Configuration Installing the Module Perform the following procedure to install the PSAX 4500 Alarm module (model 45N79) in slot 14 on the rear panel. Read the PacketStar PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, before proceeding.! CAUTION: Do not attempt to install the Alarm module (model 20N79) and PSAX 4500 Alarm module (model 45N79) in the same PSAX 4500 chassis. Page 14 of 18 PSAX 4500 Alarm Module Description and Specifications

15 ! WARNING: When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis. Install or remove modules one at a time. Doing this aids in preventing the PSAX system from indicating any erroneous failure messages, and allows the PSAX system time to reinitialize and display the accurate configuration of the module that is inserted. Installing the Module Begin 1 For older PSAX 4500 chassis with the single blank panel on the rear of the chassis, remove the rear blank panel from the chassis by removing the 10 screws with a Phillips screwdriver. For newer PSAX 4500 chassis with the 10 rear blank faceplates already installed, loosen the 2 captives screws on the blank faceplate in slot 14 with the Phillips screwdriver. 2 Remove the module from its box and ESD packaging only when you are ready to install it. Be sure to save the box and the ESD packaging to ship the module in the future if needed. 3 Open the ejector handle at the top of the module faceplate, and slide the module into slot 14 (slots labeled along bottom edge of opening or fourth slot from the left side facing the rear panel of the chassis). Be sure to position the module with the ejector handle near the top edge of the chassis opening. 4 Press on the ejector handle until it snaps firmly against the faceplate, and verify that the module is secure in its slot. 5 Secure the module with the two captive screws on the faceplate using a flathead screwdriver. 6 For the older PSAX 4500 chassis, secure the blank faceplates over the uncovered slots (slots 1 17, except slot 14) as illustrated in Figure 13. Store the rear blank panel if necessary or dispose of it in accordance with all local regulations. For newer PSAX 4500 chassis, store the blank faceplate for future use. PSAX 4500 Alarm Module Description and Specifications Page 15 of 18

16 4500 Alarm Module S T R A T U M 7 For new installations, run the cabling through a cable management system that provides the necessary connector/cable strain relief to prevent damage to the module connectors.! WARNING: To prevent any damage to the module connectors, do not allow the cables to hang unaided from the connectors. Use standard cable installation procedures to run and secure the cables through an appropriate cable management system before connecting the cables to the modules. 8 Connect the ALARM and STATUS/CONTROL cables to the appropriate faceplate connector. End BA Alarm Configuration Example PSAX 4500 Rear Panel Blank Faceplates 1-Slot 2-Slot 3-Slot Figure 13. PSAX 4500 Alarm Module Installation Verifying the Initial Startup The CRITICAL, MAJOR, and MINOR LEDs are described in Alarm Outputs on page 8. The ACO LED is described in Audible Alarm Cutoff (ACO) on page 11. Controlling the Module For information on configuring the PSAX 4500 Alarm module, see the Packet- Star PSAX Multiservice Media Gateways Product Information Library CD-ROM that accompanied your PSAX Multiservice Media Gateway system hardware shipment or your PSAX Multiservice Media Gateway system software upgrade kit. You can also separately order a printed copy of the PacketStar PSAX 4500 Alarm Module User Guide from the Lucent Technologies Customer Information Center Web site at: Page 16 of 18 PSAX 4500 Alarm Module Description and Specifications

17 Troubleshooting the Installation If you experience a problem with the PSAX 4500 Alarm module, refer to the Lucent Technologies Product Warranty Registration Information, which accompanied your shipment, for instructions on obtaining support in your area. Removing the Module Perform the following procedure to remove the PSAX 4500 Alarm module. Read the PacketStar PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, before proceeding. Removing the Module Begin 1 Disconnect the cables from the two connectors, if applicable. 2 Using a flathead screwdriver, loosen the two captive screws near the top and bottom of the faceplate. 3 Pull backward on the ejector handle until the module is pulled out of the slot. 4 Place the module in ESD packaging and close it. 5 If a replacement module is not being immediately inserted into the empty slot, insert a blank faceplate (See Required Components to Install the Module on page 14 for blank faceplate part numbers.) into the slot to prevent EMI and maintain proper air flow inside the chassis.! CAUTION: Ultimate disposal of this product should be handled according to all laws and regulations in your specific geographic region. End Regulatory Standards Compliance Safety and Electromagnetic Compatibility The PSAX 4500 Alarm module is compliant with applicable safety and EMC standards when configured with the PacketStar PSAX 4500 chassis. Refer to the appropriate PacketStar PSAX installation guide for details. PSAX 4500 Alarm Module Description and Specifications Page 17 of 18

18 The information in this document is for informational use only, is subject to change without notice, and should not be construed as a commitment by Lucent Technologies, Inc. This document is without warranty of any kind, either expressed or implied. Lucent Technologies, Inc. assumes no responsibility for any errors, inaccuracies, or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions contained herein. Lucent Technologies, Inc. is not responsible for any damage or loss to your data or equipment resulting either directly or indirectly from use of this document. Copyright 2004 Lucent Technologies All rights reserved. Printed in the USA. Part Number: 561M0A0001Z2

1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S

1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S 1-Port DS3 IMA Module Description and Technical Specifications Purpose of This Document This document identifies and describes the 1-Port DS3 IMA module and related safety information. It also includes

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: salessupport@olsontech.com www.olsontech.com

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Perle Protocol Transparent Media Converter Modules

Perle Protocol Transparent Media Converter Modules Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation

More information

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

UniStream CPU-for-Panel

UniStream CPU-for-Panel UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic

More information

About the BitStorm 6051 POTS Splitter

About the BitStorm 6051 POTS Splitter BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

8-Port E3/DS3 ATM Line Card Overview

8-Port E3/DS3 ATM Line Card Overview CHAPTER 8-Port E/DS ATM Line Card Overview This chapter describes the Cisco series 8-port E/DS ATM line card (referred to as the 8-port E/DS ATM line card) and contains the following sections: Line Card

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions TM 5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions Document Number 9000-A2-GN17-30 August 1998 Before You Begin Both the 5-slot housing and the FrameSaver

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm

More information

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap 800-0150-001 Rev. F PUBTPCU3ZDU 8/10 Gig Zero Delay Tap PLEASE READ THESE LEGAL NOTICES CAREFULLY. By using a Net Optics Tap you agree

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

AI120 AIswitch Series 120 Chassis

AI120 AIswitch Series 120 Chassis AI120 AIswitch Series 120 Chassis Guide INSTALLATION GUIDE Westell Technologies Part # 030-300715 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox and Optima Management

More information

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...

More information

Part No. P0943133 02. Business Communications Manager 2.5. BIX Box Wiring Guide

Part No. P0943133 02. Business Communications Manager 2.5. BIX Box Wiring Guide Part No. P0943133 02 Business Communications Manager 2.5 BIX Box Wiring Guide 2 Copyright 2001 Nortel Networks All rights reserved. May, 2001. The information in this document is subject to change without

More information

Remote Alarm Monitoring System

Remote Alarm Monitoring System Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada

More information

Dial Backup Module (DBM) Two standoff posts, four washers, and four Phillips-head screws 14 RJ49C ISDN-U cable Warranty card

Dial Backup Module (DBM) Two standoff posts, four washers, and four Phillips-head screws 14 RJ49C ISDN-U cable Warranty card TM ISDN BRI Dial Backup Module (DBM) Installation Instructions Document Number 9000-A2-GN19-30 Feature Number 9098-F1-870 February 1998 Before You Begin Make sure you have: Ordered ISDN service, and it

More information

Installing Your 960 or 980 Server into a Rackmount Cabinet

Installing Your 960 or 980 Server into a Rackmount Cabinet Installing Your 960 or 980 Server into a Rackmount Cabinet 1 2 Contents Installing Your Gateway Server into a Rackmount Cabinet...1 Identifyingpartsintheaccessorykit...2 Rackmounthandlekit... 2 Rackmountrailkit...

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

HP R12000 and R18000 DirectFlow UPS User Guide

HP R12000 and R18000 DirectFlow UPS User Guide HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the

More information

Refer installation of power supplies to qualified service personnel.

Refer installation of power supplies to qualified service personnel. AC Power Supply For 5-Slot Housing and 9000 Series Access Carrier Installation Instructions Document Number 9000-A2-GN17-50 August 2000 Before You Begin Both the 5-slot housing and the 9000 Series Access

More information

UPGRADING AND SERVICING GUIDE

UPGRADING AND SERVICING GUIDE UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing

More information

How to Set Up Your NSM4000 Appliance

How to Set Up Your NSM4000 Appliance How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

Comtrol Cable User Guide

Comtrol Cable User Guide Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered

More information

PCI/PXI ETHERNET ADAPTERS

PCI/PXI ETHERNET ADAPTERS INSTALLATION GUIDE PCI/PXI ETHERNET ADAPTERS Installing Your PCI Board National Instruments offers several Ethernet adapters based on the Intel 82559-compatible Ethernet controller. This document explains

More information

24-Port Channelized E1/T1 Line Card Overview

24-Port Channelized E1/T1 Line Card Overview CHAPTER -Port Channelized E/T Line Card Overview This chapter describes the Cisco series -port channelized E/T line card (referred to as the -port channelized E/T line card), and contains the following

More information

Hard Disk Drive (HDD)

Hard Disk Drive (HDD) Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Triple Expansion Chassis

Triple Expansion Chassis Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................

More information

VX 2400 Dimmer User's Manual

VX 2400 Dimmer User's Manual TM VX 2400 Dimmer User's Manual 21-2119C Manual Revision 1.01 Software Version 1.0 10 March 1994 Table of Contents 1. General Description...3 1.1. Standard Features:...3 2. Installing Options...4 2.1.

More information

Moxa EtherDevice Switch

Moxa EtherDevice Switch Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The

More information

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08 Contents Introduction.... Key Features... Unpacking and Inspection....3 Product

More information

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC BAYweb Remote Model BW-BCU5 Owner's Manual Copyright 2009-2010 Bay Controls, LLC Part Number: BW-BCU5DOC Revision: 0.2 April 18, 2010 BAYweb is a

More information

PagePac PAGEPAL V-5335700

PagePac PAGEPAL V-5335700 PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

ANTI-THEFT SYSTEM. 1995 Volvo 850 DESCRIPTION & OPERATION BASIC ALARM. 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

ANTI-THEFT SYSTEM. 1995 Volvo 850 DESCRIPTION & OPERATION BASIC ALARM. 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems ANTI-THEFT SYSTEM 1995 Volvo 850 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems 850 DESCRIPTION & OPERATION WARNING: Deactivate air bag system before performing any service operation. For 1995

More information

BX7000 Multi-Access Gateway Getting Started Guide

BX7000 Multi-Access Gateway Getting Started Guide BX7000 Multi-Access Gateway Getting Started Guide This guide provides instructions on connecting the Juniper Networks BX Series 7000 Multi-Access Gateway to a network. For more information, see the BX7000

More information

Installation Instructions for Alarm Module Kit A043F059

Installation Instructions for Alarm Module Kit A043F059 Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line

More information

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these

More information

F2400 FOM II Series Fiber Optic Modem Technical Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

GEU-0822 8-Port Gigabit Switch

GEU-0822 8-Port Gigabit Switch GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

Zetron Desktop Microphone Manual 025-9589F

Zetron Desktop Microphone Manual 025-9589F Zetron Desktop Microphone Manual 025-9589F Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is

More information

Tyan Computer. Transport PX22. Service Engineer s Manual

Tyan Computer. Transport PX22. Service Engineer s Manual Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,

More information

Power Supply Guide Version 1.0 for D-Show

Power Supply Guide Version 1.0 for D-Show Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731

More information

Cisco TelePresence VCR MSE 8220

Cisco TelePresence VCR MSE 8220 Cisco TelePresence VCR MSE 8220 Getting started 61-0008-05 Contents General information... 3 About the Cisco TelePresence VCR MSE 8220... 3 Port and LED location... 3 LED behavior... 4 Installing the VCR

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00

SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00 SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00 AN 103-4012-00, Issue 2a sageon_sm-an.pdf www.unipowerco.com SALES: +1-800-440-3504 HEAD OFFICE: +1-954-346-2442 EUROPE: +44 (0)1903 768200 SAGEON

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

The power module is Feature Number 8800-F2-901.

The power module is Feature Number 8800-F2-901. Hotwire 8820 GranDSLAM AC to DC Power Supply Installation Instructions Document Number 8800-A2-GZ41-00 AC to DC Power Supply The AC to DC Power Supply consists of a power supply chassis and one or two

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

PERF10 Rubidium Atomic Clock

PERF10 Rubidium Atomic Clock Owner s Manual Audio Stanford Research Systems Revision 1.0 February, 2011 2 Certification Stanford Research Systems certifies that this product met its published specifications at the time of shipment.

More information

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to

More information

Memory Modules User Guide

Memory Modules User Guide Memory Modules User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services

More information

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000 Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level

More information

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop

More information

16/32 Channel 1U Rack Mount CCTV Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply 16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel

More information

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009 Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,

More information

What is the Fan Tray Assembly?

What is the Fan Tray Assembly? Replacement Fan Tray Assembly for the 8820 Broadband Access Concentrator Model 8820-S2-900 Installation Instructions Document Number 8820-A2-GZ44-10 June 2004 What is the Fan Tray Assembly? The fan tray

More information

I STAR COMPUTER CO., LTD

I STAR COMPUTER CO., LTD I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON

More information

±15 V Current-Limited Power Supply

±15 V Current-Limited Power Supply USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus Warranty Newport Corporation guarantees its products to be

More information

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL

More information

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH

More information

8-Port HDMI Switch USER MANUAL VS0801H

8-Port HDMI Switch USER MANUAL VS0801H 8-Port HDMI Switch USER MANUAL VS0801H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

How To Install A Power Supply (Uplast) With A Battery Pack

How To Install A Power Supply (Uplast) With A Battery Pack APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects

More information

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service This field replacement guide provides instructions for replacing the two AC power supplies in an EX4500 Ethernet

More information

Environmental Sensors

Environmental Sensors Environmental Sensors Guide Revision 0A Copyright 2014 Raritan, Inc. SENSOR-0A-PXv3.0.0-E June 2014 255-90-0003-00 This document contains proprietary information that is protected by copyright. All rights

More information

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual DE1600 DSA E-Series iscsi Disk Arrays en Installation Manual DE1600 DSA E-Series iscsi Disk Arrays Table of Contents en 3 Table of Contents 1 Safety Precautions 4 1.1 Warning Notices 4 1.2 Caution Notices

More information

Interface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21

Interface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21 Overview Models HP Server Console Switches 1X8-Port KVM 336044-B21 2X16-Port KVM 336045-B21 CAT5e Cables 3 Foot (1 m) 4 pack 263474-B21 6 Foot (2 m) 8 pack 263474-B22 12 Foot (4 m) 8 pack 263474-B23 20

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

Copyright 2002-2004 Triple S Customs

Copyright 2002-2004 Triple S Customs JEEP GRAND CHEROKEE 1992-2006 VEHICLE WIRING Copyright 2002-2004 Triple S Customs WIRING INFORMATION: 1992 Jeep Grand Cherokee 12V CONSTANT WIRE PINK/BLACK or RED/WHITE Steering Column STARTER WIRE YELLOW/BLUE

More information

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129 PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,

More information

Model 3000-51 20 SPDT Relays 90401460

Model 3000-51 20 SPDT Relays 90401460 Model 3000-51 20 SPDT Relays 90401460 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,

More information

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide VOT-320 VOT-320V0xxL VOT-320V0xxH en Quick Installation Guide VOT-320 Table of Contents en 3 Table of Contents 1 General information 4 2 Parts included 5 3 Unpacking 6 4 Installing and connecting 7 4.1

More information

SPC-530. Rackmount Server PC. User's Manual

SPC-530. Rackmount Server PC. User's Manual SPC-530 Rackmount Server PC User's Manual Copyright Notice This document is copyrighted, April 2000, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements

More information

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel

More information

Contents. Installing the upgrade memory kit in the G450 and G430 Media Gateway May 2014 1

Contents. Installing the upgrade memory kit in the G450 and G430 Media Gateway May 2014 1 Contents Installing the upgrade memory kit in the G450 / G430 Media Gateway... 3 Equipment ordering... 3 Inserting or replacing a RAM card... 4 Inserting or replacing a RAM card in the G450... 4 Replacing

More information

Owner's Copy. 104873 December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

Owner's Copy. 104873 December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS 104873 December 14, 2011 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com ELECTRICAL

More information

WIRELESS STATUS MONITOR

WIRELESS STATUS MONITOR INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,

More information

Kvaser Mini PCI Express User s Guide

Kvaser Mini PCI Express User s Guide Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate

More information