1 Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009
2 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology, Inc. Intel is a registered trademark of Intel Corporation. Other trademarks are the property of their respective owners. Copyrights This guide is Copyright 2009 by Riverbed Technology, Inc. All rights reserved. Version March 2009 ii
3 Contents Introduction... 1 Unpacking and inspection... 1 Preparing to install the hardware... 2 Card mounting considerations... 2 Cabling considerations... 2 Installing the FC HBA card... 3 Preparing to configure the software... 4 Contacting Riverbed Technical Support... 5 iii
4 iv
5 Profiler Fibre Channel SAN Attached Storage Installation Guide Introduction The Fibre Channel Host Bus Adapter (FC HBA) enables Riverbed Cascade Profiler to access remote storage on a Storage Area Network (SAN) device as if it were a local SCSI disk. This requires you to configure your FC switches or SAN storage devices as necessary to allow connections from Profiler and to assign storage resources to the Profiler. Software configuration requires guidance from Riverbed Technical Support. It is not necessary to configure the software at the time that the hardware is installed. All other Profiler features will function normally without the software for the SAN interface being configured. However, the software must be configured and a SAN device connection must be available in order to verify the installation and operation of this option. Installation involves the following steps: 1. Unpack and inspect the hardware 2. Prepare to install the hardware 3. Install the FC HBA card 4. Prepare to configure the software 5. Contact Riverbed Technical Support for guidance on configuring software Safety Notice Hardware installation involves accessing the inside of the Profiler chassis. To reduce the risk of personal injury or equipment damage, observe the chassis hardware manufacturer s safety warnings and cautions, which are provided in the documentation kit shipped with the Profiler. Unpacking and inspection 1. If you have ordered SAN options for more than one Profiler, check the shipping documentation to ensure that all components have arrived. 2. Visually inspect the shipment for indications of damage. 3. If any pieces of your order are damaged or missing, contact Riverbed Technical Support before continuing. Phone United States and Canada: Phone outside U.S. and Canada: support@riverbed.com Web: 1
6 Profiler Fibre Channel SAN Attached Storage Installation Guide Preparing to install the hardware Card mounting considerations The FC HBA is low-profile PCI Express 4 card. It plugs into one of the fullheight PCIe (PCI Express) slots of the Profiler chassis. The WWN (world wide name) of each of the two ports is printed beside the connector. Although these are visible after the card is installed in the chassis, it may be more convenient to record them before installing the card. Cabling considerations The FC HBA card has two 4-Gbps Fibre Channel connectors. The connectors are LC-style for small form factor (SFF) multimode fiber optic cables. They can be connected to a Fibre Channel switch or storage device over the following lengths of cable: Speed (4/2/1 Gbps auto-negotiated) 50/125 μm fiber cable 62.5/125 μm fiber cable Gbps 150 meters 70 meters Gbps 300 meters 150 meters Gbps 500 meters 300 meters Ensure that cables with the correct connectors are available at the Profiler mounting location to connect the FC ports to the SAN device. 2
7 Profiler Fibre Channel SAN Attached Storage Installation Guide Installing the FC HBA card To install the FC HBA card in the Profiler chassis: 1. Power off the Profiler. The power button is located behind the bezel on the front of the chassis, near the center of the control panel on the upper-right. When Profiler completes powering off, the green Power indicator begins blinking. This indicates that power is still present in the chassis. 2. Unplug all cables and remove the Profiler chassis from the rack. 3. Remove the screw fastening the top cover and remove the top cover. 4. Remove the processor air duct (plastic insert). 5. Remove the PCI riser by lifting the two blue locking latches and then pulling the riser assembly straight up. 6. Locate an empty full-height PCI-e slot in the PCI riser assembly. 7. Insert the FC HBA card in the slot, ensuring that it is seated properly. 8. Reinstall the PCI riser assembly in its original position. Use the latches to lock it in place, making sure it is seated properly. 3
8 Profiler Fibre Channel SAN Attached Storage Installation Guide CAUTION: 9. Replace the processor air duct, the top cover, and the top cover screw. 10. Reinstall the Profiler in the rack. Observe the safety cautions in the mounting instructions that are shipped with the Profiler. 11. Reconnect the power cable and management network cable. 12. Connect the fiber cable from the SAN device to one of the FC HBA connectors on the rear of the Profiler chassis. 13. Power on the Profiler and reinstall the bezel on the front of the chassis. 14. After 5 minutes, verify that the Link LEDs are lit on both the Profiler FC HBA card and the Fibre Channel device to which it is cabled. At this point, hardware installation is complete and Profiler should be operating normally, although the SAN option will not be operational until the software configuration is completed. Preparing to configure the software All Profiler models include the driver for the SAN interface (Fibre Channel Host Bus Adapter, FC HBA) and the commands necessary to establish a connection with a SAN device. Nothing needs to be downloaded or loaded from disk. Ensure that the following conditions are met and information is available before you begin the software configuration. LUN The SAN administrator must allocate a LUN (logical unit number) for Profiler to use. Note that Profiler will reformat and partition its assigned storage area. Any data on that LUN will be lost unless you specify a command option that prevents Profiler from copying its existing logs to its LUN. WWN The administrator s SAN management solution must associate the LUN with the World Wide Name (WWN) of the Profiler FC HBA port that is to access the SAN device. (The WWN is printed beside the connector.) Login The person performing the software configuration must be able to access the Profiler command line interface and log in to the account named mazu. For an Enterprise Profiler system, they must by able to log in to each Analysis Module. Link The link level connection between Profiler and an FC device must be in operation. This requires only that the Profiler FC HBA is running and cabled to a Fibre Channel device, such as a switch or storage device. 4
9 Profiler Fibre Channel SAN Attached Storage Installation Guide Schedule Profiler will be off line briefly during the software configuration procedure. If downtime is a consideration, discuss this with Riverbed Technical Support when you set up a time for configuring the software. Contacting Riverbed Technical Support Contact Riverbed Technical Support to discuss and schedule the software configuration. A Riverbed engineer will assist you in configuring the software and verifying that the installation is successful. Also contact Riverbed Technical Support if you would like Riverbed to perform the installation. Phone United States and Canada: Phone outside U.S. and Canada: support@riverbed.com Web: 5
10
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions Congratulations on your purchase of the 8Gb Simple SAN Connection Kit. This guide provides procedures for installing the kit components,
More informationDD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
More informationDD160 and DD620 Hardware Overview
DD160 and DD620 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0206-0001 Revision A March 21, 2011 Copyright 2011 EMC Corporation.
More informationExpress5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationHP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
More informationIntel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
More informationSmall form factor bay converter and hard drive installation
Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold
More informationFront Panel Board Cable Replacement Instructions
apple Mac Pro Front Panel Board Cable Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and void its warranty.
More informationProcessor Cage Fans, Front and Rear Replacement Instructions
apple Mac Pro Processor Cage Fans, Front and Rear Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and
More informationQuantum Scalar 50 Tape Drive Installation Instructions
Quantum Scalar 50 Tape Drive Installation Instructions Introduction 3 Tape Drive Numbering... 3 Scalar 50 Tape Drive Upgrade Kits... 4 Required Tools... 6 Unpacking the Tape Drive 6 Installing the Tape
More informationIntel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
More informationSAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationPackage Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.
Package Contents DSN-3200/3400 xstack Storage Area Network (SAN) Array CD-ROM with User Guide Keys Rack mount Rails Power Cables Hardware and Screws 2 If any of the above items are missing, please contact
More informationReplacement Instructions. Warning: During this procedure, keep small parts away from children.
apple Power Mac G4 / Macintosh Server G4 ATA Hard Drive Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void
More informationDF-7506 1-to-2 SATA II RAID Box
DF-7506 1-to-2 SATA II RAID Box Version 1.0 Table of Contents Chapter 1 Product Introduction...3 1.1 Features...3 1.1.1 Shipping Package Content...3 1.2 Front View...4 1.3 Rear View...6 1.4 Disk Drive
More informationHP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007
HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007 United States Copyright 2007 Hewlett-Packard Development Company L.P.. Legal Notices
More informationMercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
More informationSet Up Your MXI -Express x1 System
Set Up Your MXI -Express x1 System Terminology This document explains what is needed to set up various MXI-Express x1 hardware configurations. The products covered by this guide are the NI PCI-8361, NI
More informationUpgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module
Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module May 2011 51358-00, Rev. A ST2501 M2 Drive Module Initial Setup Guide May 2011 Revision History Version and Date 51358-00,
More informationUPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M5 13 8 To mount outer member to rack
UPDATEUPDATEUPDATE Converting the tower chassis to a rack-mount chassis Rail overview Converting your Server to Rack-Mount The rail kit includes the following: Two rail units Five packages of screws (labeled
More informationSCSI Card 2930CU. Installation Guide
R SCSI Card 2930CU Installation Guide This Installation Guide describes how to install the Adaptec SCSI Card 2930CU. It also describes how to install and connect your internal and external SCSI devices.
More informationHP ProLiant DL380 G5 High Availability Storage Server
HP ProLiant DL380 G5 High Availability Storage Server installation instructions *5697-7748* Part number: 5697 7748 First edition: November 2008 Legal and notice information Copyright 1999, 2008 Hewlett-Packard
More informationINTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO
2940UWPro-ig.qxd 12/21/98 9:55 AM Page 1 INTRODUCTION With the SCSI Card 2940UW Pro, you can connect up to 15 SCSI devices to any IBM-compatible computer with PCI expansion slots. This installation guide
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationHP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
More informationHP Integrity rx2660 Server Installation Guide
HP Integrity rx2660 Server Installation Guide HP Part Number: AB419-9000C Published: November 2007 Copyright 2007 Hewlett-Packard Development Company, L.P Legal Notices The information contained herein
More informationHP 16/18-Port Cable Management Kit Installation Guide
HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed
More informationSC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two
s SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two EM Guidelines, 1997-04-02 E331.E539U.640.10.03.02 ASK-A898-03-7600 Page 1 of 16 Service Manual
More information4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card User Manual Model: UGT-ST644R All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction...
More informationTaurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
More informationHP 22-in-1 Media Card Reader
HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket
More informationChapter 2 Installation
Installation Chapter 2 Installation This chapter will guide you through the installation of the Quartet Serial PCI. There are no jumpers or switches to set for this PCI Plug-n-Play board. 2-1 Hardware
More informationSet Up Your MXI -Express x4 System
Set Up Your MXI -Express x4 System Terminology This document explains what you will need to set up various MXI-Express x4 hardware configurations. The products covered by this guide are the NI PCIe-8371/8372
More informationHP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
More informationUnpack and Install the Devices, Accessories, and Cables
READ ME FIRST NI-DAQmx and DAQ Device Installation Guide Français Deutsch ni.com/manuals Install your software before installing new hardware. Install Application Software Install NI application software,
More informationPackage Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.
Package Contents DSN-3200/3400 xstack Storage Area Network (SAN) Array CD-ROM with User Guide Keys Rack mount Rails Power Cables Hardware and Screws 2 If any of the above items are missing, please contact
More informationSerial ATA to Serial ATA
Serial ATA to Serial ATA Model: MRK-300ST-BK Aluminum Mobile Rack 3-1 3-1 Introduction... 3-3 Mobile Rack Features... 3-3 Unpacking Your Mobile Rack... 3-4 IDE Basics... 3-4 3-2 Hardware Installation...
More informationQLogic 8Gb FC Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide
QLogic 8Gb FC Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide The QLogic 8Gb FC Single-port and Dual-port HBA for IBM System x are PCI Express 2.0 x8 8Gb Fibre Channel adapters
More informationInstalling Your 960 or 980 Server into a Rackmount Cabinet
Installing Your 960 or 980 Server into a Rackmount Cabinet 1 2 Contents Installing Your Gateway Server into a Rackmount Cabinet...1 Identifyingpartsintheaccessorykit...2 Rackmounthandlekit... 2 Rackmountrailkit...
More informationHP 36-Port InfiniBand Switch Cable Management Kit Installation Guide
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein
More informationInspiron 15. Service Manual. 3000 Series
Inspiron 15 3000 Series Service Manual Computer Model: Inspiron 15 3541/Inspiron 15 3542/Inspiron 15 3543 Regulatory Model: P40F Regulatory Type: P40F001/P40F002 Notes, Cautions, and Warnings NOTE: A NOTE
More informationQuick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
More informationEVGA Z97 Classified Specs and Initial Installation (Part 1)
User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
More informationInstallation and Setup Guide EMC DATA DOMAIN DD610 STORAGE SYSTEM
Installation and Setup Guide EMC DATA DOMAIN DD610 STORAGE SYSTEM Installation and Setup Steps The steps for a complete installation and configuration are: 1. 1 Install Hardware 2. 2 Define the Data Domain
More informationDell PowerVault RD1000. User's Guide
Dell PowerVault RD1000 User's Guide NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data
More informationPCI/PXI ETHERNET ADAPTERS
INSTALLATION GUIDE PCI/PXI ETHERNET ADAPTERS Installing Your PCI Board National Instruments offers several Ethernet adapters based on the Intel 82559-compatible Ethernet controller. This document explains
More informationInspiron 13. Service Manual. 7000 Series. Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001
Inspiron 13 7000 Series Service Manual Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps
More informationNote: Copyright. The most current information about this product is available at Tandberg Data s web site (http:// www.tandbergdata.com).
Copyright Copyright 2010 Tandberg Data Corporation. All rights reserved. This item and the information contained herein are the property of Tandberg Data Corporation. No part of this document may be reproduced,
More informationAccessing the printer system board
Accessing the printer system board 1 Turn the printer off. 2 Unplug the printer power cord. 3 Disconnect all cables from the back of the printer. 4 Locate the metal plate at the back of the printer. Loosen
More informationHigh Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-
More informationQuick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX
Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX AA RFBCA TE 387373-001 Before You Begin In this Quick Setup Guide we tell you how to create an initial
More informationRemoving memory and option cards
These instructions can help you remove memory or option cards. Use the following illustration to locate the connector for the card you want to remove. Hard disk connector 1 Option card connector Firmware
More informationHow To Install A Cisco Cisco 520-T1 Router On A Network Card (Cisco) With A Network Cable (Cio) And A Network (Cnet) (Coconc) (Net) And An Ipo (
Quick Start Guide Cisco Small Business Pro SR 520-T1 Secure Router Package Contents SR 520-T1 Secure Router Ethernet Network Cable Console Cable AC Power Cord and AD/DC Power Adapter Power Cord Locking
More informationHP Optical Bay Hard Drive Bracket
HP Optical Bay Hard Drive Bracket Introduction This document describes how to install 8.89 cm (3.5 inch) hard drives in the HP optical bay hard drive bracket and install the bracket in the optical drive
More informationPS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
More informationDell Inspiron 660s Owner s Manual
Dell Inspiron 660s Owner s Manual Computer model: Inspiron 660s Regulatory model: D06S Regulatory type: D06S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
More informationAcano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B
Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following
More informationHydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0
4-Bay RAID Storage Enclosure User Manual January 16, 2009 - v1.0 EN Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC Requirements... 1 1.1.2 Mac Requirements... 1 1.1.3 Supported
More informationPost-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000
Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products
More informationactitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide
actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide Page 1 of 11 Introduction This poster describes how to install your ActiTape LTO half-height internal tape drives with SCSI and SAS interface.
More informationWinlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System
Winlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System Copyright 2002 by Winlead Dialer Software 1.0 - Install Guide for Winlead Dialer Software Software
More informationPCIe Gigabit Ethernet Card
PCIe Gigabit Ethernet Card User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. 1 Features Designed to meet PCI Express Base Specification Revision 1.0a Single-lane
More informationProLiant DL380 Generation 2 Server Maintenance and Service Guide
ProLiant DL380 Generation 2 Server Maintenance and Service Guide Second Edition (June 200) Part Number 203840-002 Spare Part Number 228520-00 Compaq Computer Corporation Notice 200 Compaq Computer Corporation
More informationCalDigit SuperSpeed PCI Express Card
CalDigit SuperSpeed PCI Express Card For more information visit www.caldigit.com Fast, Reliable and Secure Storage Solutions Apple, Apple Logo, Mac, the Mac logo and Macintosh are trademarks of Apple Inc.
More informationilan Ethernet Box for 9100 Installation Manual
ilan Ethernet Box for 9100 Installation Manual 07103-00154 March 11, 2014 Corporate Headquarters: 21405 B Street Long Beach, MS 39560 Phone: (800) 259-6672 Fax: (228) 868-9445 Copyright Notice 2014 Triton.
More informationPN 100-06843L, Revision B, October 2013. Epic 950 TM. Master Programmer User s Guide
PN 100-06843L, Revision B, October 2013 Epic 950 TM Master Programmer User s Guide This page intentionally left blank Change History Rev A Initial release Feb 2007 Rev B Update Oct 2013 100-06843L Rev
More informationYour Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012) www.raidon.com.tw
SafeTANK GR5630-WSB3+ User Manual v..0 (Oct, 202) Introduction Thank you for purchasing RAIDON products. This manual will introduce the GR5630-WSB3+. Before using your GR5630-WSB3+, please read this manual
More informationHP Laser Jet 4200/4240/4250/4300/4350 Swing Plate
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate 1 Swing Plate Assembly-RM1-0043 1 Swing Plate Kit-5851-2766 (RM1-0043 plus RM1-1091 gear) CAUTION: Fuser may be hot. Turn off printer, unplug it and allow
More informationRSA Security Analytics. S4 Broker Setup Guide
RSA Security Analytics S4 Broker Setup Guide Copyright 2010-2013 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or trademarks
More informationHow To Set Up An Inverter
MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar Safety Safety Safety Message Types WARNING Safety information important for human safety.
More informationRack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
More informationUPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
More informationLSI MegaRAID SAS 8888ELP Host Bus Adapter installation
LSI MegaRAID SAS 8888ELP Host Bus Adapter installation Introduction This document describes how to install the LSI MegaRAID SAS 8888ELP Host Bus Adapter (HBA) in HP and xw series Workstations. Procedures
More informationQuick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches
Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.
More informationHP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in
HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...
More information3-Port FireWire 800/400 PCI Host Card
3-Port FireWire 800/400 PCI Host Card 400 FireWire Low Included FireWire Upgrade to FireWire800! U S E R S M A N U A L Low FireWire 400 Included Package Contents : 1 3-Port FireWire 800/400 PCI Host Card
More informationHow to Set Up Your NSM4000 Appliance
How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper
More informationReadyNAS OS 6 Desktop Storage Systems
ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: ReadyNAS 102 ReadyNAS 104 ReadyNAS 312 ReadyNAS 314 ReadyNAS 316 ReadyNAS 516 ReadyNAS 716X EDA 500 October 2013 202-11206-04 350 East Plumeria
More informationCompaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
More informationPCIe SATA 6G Raid Card
PCIe SATA 6G Raid Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...
More informationSGI InfiniteStorage NAS 50/100 Quick Start Guide 007-5621-001
SGI InfiniteStorage NAS 50/100 Quick Start Guide 007-5621-001 COPYRIGHT 2010 SGI. All rights reserved; provided portions may be copyright in third parties, as indicated elsewhere herein. No permission
More informationRack Installation Instructions
Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the
More informationInfinity C Reference Guide
1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...
More informationNetwork Interface Upgrade
Sidewinder G 2 Security Appliance Version 6.1 Network Interface Upgrade About this document Thank you for ordering the quad port UTP (Unshielded Twisted Pair) PCI X Ethernet controller hardware component
More informationRack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
More informationRevision 433599-06 2012-07-18
Revision 433599-06 2012-07-18 2 Copyright 2012 Tandberg Data GmbH The information contained in this document is subject to change without notice. This document contains proprietary information which is
More informationTyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
More informationStorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
More informationTorpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3
Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3 Author: Conor Malone, VP Engineering, Hyve Solutions 1 Scope This document discusses the requirements and specifications
More informationUSB 3.0 4-Port PCI Express Card
USB 3.0 4-Port PCI Express Card User Manual Model: UGT-PC341 All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction... 3 1.1 Product
More informationUsing RAID Admin and Disk Utility
Using RAID Admin and Disk Utility Xserve RAID Includes instructions for creating RAID arrays and monitoring Xserve RAID systems K Apple Computer, Inc. 2003 Apple Computer, Inc. All rights reserved. Under
More informationTaurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual
Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual v1.0 August 23, 2007 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 9 ICON KEY 1 THE TAURUS RAID 1 AVAILABLE
More informationPower Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
More informationUsing a Fabric Extender with a Cisco Nexus 5000 Series Switch
CHAPTER Using a Fabric Extender with a Cisco Nexus 5000 Series Switch This chapter describes the Cisco Nexus 000 Series Fabric Extenders (FEXs) and includes these sections: Information About, page - Cisco
More information4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
More informationQuick Start Guide for Tempo RAID66
Quick Start Guide for Tempo RAID66 You Should Have The following items should be included in your product package: One Tempo RAID66 PCI Macintosh Two Ultra ATA/66 Cables (supports four internal hard drives)
More informationMaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement
MaxAttach NAS 4000 Series MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement DOCUMENT OVERVIEW Who Should Use This Instruction Set This MaxAttach NAS 4000 Series by Maxtor HDD Replacement Instruction
More information1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S
1-Port DS3 IMA Module Description and Technical Specifications Purpose of This Document This document identifies and describes the 1-Port DS3 IMA module and related safety information. It also includes
More information