SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE
|
|
- Percival Todd
- 8 years ago
- Views:
Transcription
1 PART 1 - GENERAL 1.1 SUMMARY SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE A. Section Includes 1. Video Surveillance Systems Infrastructure B. Related Sections 1. Section [ Video Surveillance Monitoring and Supervisory Interfaces] 2. Section [ Digital Video Recorders and Analog Recording Devices] 3. Section [ Video Surveillance Remote Devices and Sensors] **********Specifier s note: Include those standards referenced elsewhere in this SECTION. 1.2 REFERENCES A. European Norm 1. EN class A (CE) Information Technology Equipment Radio Disturbance Characteristics Limits and Methods of Measurement for Emission 2. EN (CE) Information Technology Equipment Immunity Characteristics Limits and Methods of Measurement 3. EN (CE) Electromagnetic Compatibility Limits for Harmonic Current Emissions 4. EN (CE) Electromagnetic Compatibility Limits Limitation of Voltage Changes, Voltage Fluctuations and Limitation of Voltage B. Federal Communications Commission (FCC) 1. Complies with FCC Part 15 C. Underwriters Laboratories, Inc. (UL/cUL) 1. UL Information Technology Equipment - Safety D. International Organization for Standardization (ISO) Quality System 1.3 SYSTEM DESCRIPTION A. The fiber transceiver shall provide the ability simultaneous transmission of 1-ch POTS or PBX telephone signal with one DIP selectable data (RS-422/RS-485/Manchester/Biphase) over one fiber. The transceiver shall be available in multimode and single-mode versions. B. The fiber transmitter and receiver shall have a stand-alone and rack-mountable modular design. Proj. Name/Proj. No Video Surveillance Systems Infrastructure
2 1.4 SUBMITTALS A. Submittals shall be made in accordance with the Conditions of Contract and provisions of Section [ ]. B. Manufacturer s Product Data: Submit manufacturer s datasheets, user and installation manuals for all equipment and software programs proposed for use. C. Shop Drawings: Submit the installation drawings, including the wiring diagram, list of connected equipment, and system device locations on the architectural floor plan layout. 1.5 QUALITY ASSURANCE A. Manufacturer: Manufacturers shall have a minimum of ten (10) years full time experience in manufacturing and designing Video Surveillance Systems. B. The product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001:2008 Quality System. C. Installer: Installers shall have a minimum of two (2) years experience in installing similar systems and shall be acceptable to the manufacturer of the system. 1.6 DELIVERY, STORAGE AND HANDLING A. Packing and Shipping: The products shall be delivered in manufacturer s original, unopened, undamaged container with identification labels intact. B. Storage and Protection: The products shall be stored and handled in accordance with manufacturer s requirements in facility where environmental conditions are within recommended limits. 1.7 WARRANTY A. The manufacturer s warranty shall cover three (3) years for replacement and repair of defective equipment. 1.8 MAINTENANCE A. Ordering of new equipment for expansions, replacements, and spare parts shall be made available to dealers and end users. B. Factory direct technical support shall be provided via phone and . Proj. Name/Proj. No Video Surveillance Systems Infrastructure
3 PART 2 - PRODUCTS 2.1 FIBER OPTICS A. The fiber transceiver shall provide the ability simultaneous transmission of 1-ch POTS or PBX telephone signal with one DIP selectable data (RS-422/RS-485/Manchester/Biphase) over one fiber. The transceiver shall be available in multimode and single-mode versions. B. The fiber transceiver shall have a stand-alone and rack-mountable modular design. C. Rack mount card units shall have short circuit protection with Printed Circuit Board (PCB) mounted automatic re-settable fuses; "Hot" swapping capability - installation or removal with power on; built in circuitry for power supply redundancy. D. The fiber transceiver shall be immune to Electro Magnetic Interference (EMI) and Radio Frequency Interference (RFI). E. The fiber transceiver shall meet or exceed the following design and performance specifications. 2.2 AUDIO PERFORMANCE A. Ringer Voltage: 75 VRMS typical, 90 VRMS maximum B. Ringer Detection Voltage: thirty-five volts (35V) C. Ringer Frequency: 17 ~ 60 Hz D. Ringer Holdup Time: two hundred milliseconds (200ms) E. Feedback Loss: forty decibels (40dB) typical, thirty decibels (30dB) minimum F. Free Channel Signal Noise: seventy-five decibels (75dB) (weighted) G. Balanced: seventy decibels (70dB) typical, sixty decibels (60dB) minimum H. Connector: RJ DATA PERFORMANCE A. Data Rate: DC to kbps B. Bit Error Rate: <10-9 C. Connector: 4-pin terminal block 2.4 OPTICAL/LED SPECIFICATION A. Multi-mode Performance: 1. Output Power: -15 dbm (typical) 2. Receiver Sensitivity: -27 dbm (typical) 3. Wavelength: 1310/1550 nm 4. Connector: ST B. Single-mode Performance: 1. Output Power: -10 dbm (typical) 2. Receiver Sensitivity: -30 dbm (typical) 3. Wavelength: 1310/1550 nm Proj. Name/Proj. No Video Surveillance Systems Infrastructure
4 4. Connector: FC C. LED Indicators 1. Power On: red 2. Optical Link Loss: red 3. Call Incoming: green 4. Call Received: green 5. Data Input/Output: green 2.5 COMMUNICATION A. N/A 2.6 ELECTRICAL SPECIFICATIONS A. Power Supply: twenty four volts of alternating current (24VAC) B. Power Consumption: below five point five watts (<5.5 W) C. Mean Time Between Failures: over one hundred thousand hours (>100,000 Hrs) 2.7 ENVIRONMENTAL SPECIFICATIONS A. Operating Temperature: minus forty to one hundred sixty-seven degrees Fahrenheit (-40 F ~ 167 F) (-40 C ~ 74 C) B. Storage Temperature: minus forty to one hundred eighty-five degrees Fahrenheit (-40 F ~ 185 F) (-40 C ~ 85 C) C. Humidity: zero to ninety-five percent relative humidity (0~ 95% RH) non-condensing 2.8 MECHANICAL SPECIFICATIONS A. Mount: stand-alone, rack mount 2.9 SUGGESTED MODEL Infinova model N3586, N3786 or pre-approved equivalent 2.10 OPTIONS A. Fiber Type: 1. Multi-mode 2. Single-mode B. Enclosure: 1. Stand-alone module 2. Card unit Proj. Name/Proj. No Video Surveillance Systems Infrastructure
5 PART 3 - EXECUTION 3.1 EXAMINATION A. Examine site conditions and notify adverse conditions affecting installation or subsequent operation. B. Do not begin installation until unacceptable conditions are corrected. 3.2 INSTALLATION A. All systems and components shall have been thoroughly tested before shipping to the project location. B. Install the systems in accordance with the manufacturer s recommended procedures. C. Perform installation with qualified service personnel. D. Ensure selected location is secure and offers protection from accidental damage. E. Location must provide reasonable temperature and humidity conditions, free from sources of electrical and electromagnetic interference. 3.3 FIELD QUALITY CONTROL A. Test snugness of mounting screws of all installed equipment. B. Test proper operations of the device. C. Determine and report all problems encountered to the manufacturer. 3.4 COMMISSIONING A. Test the device as recommended by the manufacturer. B. Ensure the device operates to manufacturer s specifications. C. Provide related documentations, including but not limited to the Operation and Installations Manuals. 3.5 DEMONSTRATION A. Demonstrate at final inspection that the device functions properly. End of Section Proj. Name/Proj. No Video Surveillance Systems Infrastructure
Product Guide Specification
Americas Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: + 1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East,
More information2-Pair HDSL1 Adtran Fiber Optic Link System
ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More informationSECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationDTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender
DTS/DRS-1000RV Owner s Manual DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender DRS-1000RV: DVI/VGA or VGA, Audio, RS-232C Receiver Extender Dtrovision LLC 9A Bergen Turnpike Little Ferry,
More informationDisplayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
More informationI STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
More informationHDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
More informationWiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationF2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
More informationFVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface
More informationGigabit Switching Ethernet Media Converters - Product User Guide
Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic
More informationIndustrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
More informationG-TAP A Series // Data Sheet
Product The GigaTAP A Series is a line of network TAPs designed with the Gigamon Always On architecture. This one-of-a-kind architecture eliminates network link downtime on network connections through
More informationFOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
More informationXPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationPerle Protocol Transparent Media Converter Modules
Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation
More informationBroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
More informationVX 2400 Dimmer User's Manual
TM VX 2400 Dimmer User's Manual 21-2119C Manual Revision 1.01 Software Version 1.0 10 March 1994 Table of Contents 1. General Description...3 1.1. Standard Features:...3 2. Installing Options...4 2.1.
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationStand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
More information8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
More informationCPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
More informationUSER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
More informationDVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters
Description DVI (Digital Visual Interface) recently becomes an popular interface between monitor and PC. Electrical signal limits the transmission length and quality. APAC DVI extender helps DVI to transmit
More informationSmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationDVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters
Description DVI (Digital Visual Interface) recently becomes an popular interface between monitor and PC. Electrical signal limits the transmission length and quality. APAC DVI extender helps DVI to transmit
More informationUNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES
UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)
More informationHarmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More information7 MEGAPIXEL 180 DEGREE IP VIDEO CAMERA
Scallop Imaging is focused on developing, marketing and manufacturing its proprietary video imaging technology. All our activities are still proudly accomplished in Boston. We do product development, marketing
More informationDATA SHEET DVI - HDCP Extension Cable
DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationBLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.
ServSwitch DKM DVI-D KVM Matrix Switch Delivers instant switching in four different modes for data center, control room, and classroom settings. BLACK BOX Scalable matrix KVM switch supports up to 1024
More informationUSER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)
USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M) An ISO-9001 Certified Company Part# 07M2300M Doc# 077321U Rev. A Revised 4/14/03 SALES OFFICE (301) 975-1000
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationUSER MANUAL VS92A / VS94A / VS98A
Video Splitter USER MANUAL VS92A / VS94A / VS98A FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
More informationModel SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
More informationLevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationHFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
More informationAC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models
TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual
More informationCisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
More informationDCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More informationinnkeeper PBX Desktop Digital Hybrid User Guide JK Audio
innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Introduction Innkeeper PBX will allow you to send and receive audio through your multi-line PBX, ISDN or analog telephone. While this may seem like
More informationinnkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty
Warranty Innkeeper PBX is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the innkeeper PBX needs repair, you must call us to get an authorization, and
More information8-Port HDMI Switch USER MANUAL VS0801H
8-Port HDMI Switch USER MANUAL VS0801H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
More informationIxia Net Optics 10G Regen Tap
Ixia Net Optics 10G Regen Tap Ixia Net Optics 10G Regen Taps solve the key physical layer challenges of multi-device monitoring for 10 Gigabit and gigabit networks. For a complete picture of network health,
More informationContents. Safety Warnings... 1
Contents Safety Warnings... 1 Unpacking the GQ600... 1 Introduction... 2 GQ600 Filter Characteristics... 2 1/3 Octave Centre Frequencies... 4 Front Panel Functions... 5 Rear Panel Functions... 6 Specifications...
More informationUninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
More informationTC3848. Applications. A JumboSwitch Technology
TC3848 A JumboSwitch Technology 4 + 1 FXO; or 5 FXO Extreme Temp (-40 C to +80 C) Optional Audio Codes Standards G.711 ALAW/ULAW G.726-32 T.38 Fax Internal Address Book Compatible with SIP Manage via Web,
More informationModel #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationPBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio
PBXport Rackmount PBX Digital Hybrid User Guide JK Audio Introduction PBXport will allow you to send and receive audio through your multiline PBX, ISDN or analog telephone. While this may seem like a simple
More informationDear Customer! Thank you for choosing our product.
Dear Customer! Edition 1.4 Thank you for choosing our product. MIDI AMP CONTROLLER MAC-4.4 is an adaptor that enables to control (switch the channels, switch on/off other functions) the amps equipped with
More informationUniversal Host. Desktop Digital Hybrid. User Guide. JK Audio
Universal Host Desktop Digital Hybrid User Guide JK Audio Introduction Universal Host will allow you to send and receive audio through your multi-line PBX, ISDN, VoIP or analog telephone. While this may
More informationAXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
More informationwww.murata-ps.com D1U54P-W-1200-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter www.murata-ps.com/support PRODUCT OVERVIEW FEATURES
www.murata-ps.com PRODUCT OVERVIEW D1U54P-W-1200-12-HxxC Series The D1U54P-W-1200-12-HxxC series are 80 PLUS Platinum effi ciency 1200 watt, power factor corrected front end supplies with a 12V main output
More informationHDMI Matrix Switch USER MANUAL VM0404H
HDMI Matrix Switch USER MANUAL VM0404H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
More informationzseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s
TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an
More informationSmart Pro Rack/Tower UPS Intelligent, line interactive network power management system
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationUSER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.
The leader in rugged fiber optic technology. USER GUIDE! Lifetime Warranty U-04 015A-01 Channel POTS Mux DIN Fiber Link System SYSTEM INSTALLATION INFORMATION Introduction The Channel POTS Mux DIN Fiber
More informationENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
More informationCalMod Design-Build Electrification Services
SECTION 28 16 00 INTRUSION DETECTION SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the detailed technical requirements for the Intrusion Detection System (IDS), where the Contractor
More informationSmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
More informationPerle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
More informationChrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
More informationQuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationTCB-2 Auto Answer Coupler Product Manual
TCB-2 Auto Answer Coupler Product Manual About Comrex Comrex has been building reliable, high quality broadcast equipment since 1961. Our products are used daily in every part of the world by networks,
More information4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature
4-Port 10/Mbps with + 1-Port FX Industrial Ethernet Switch Wide Temperature 15 F Fiber Optic Link Capability for Flexible Distance Extension The series equips one Base-FX port that provides more flexibility
More informationSOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C37.94. Fiber Service Units
SOLUTIONS FOR AN EVOLVING WORLD T1/E1 and C37.94 Fiber Service Units T1/E1 & C37.94 1 April 2013 Your world is changing and so are we. At RFL, we know your needs change much faster than your infrastructure.
More informationModel 3000-51 20 SPDT Relays 90401460
Model 3000-51 20 SPDT Relays 90401460 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,
More informationPagePac PAGEPAL V-5335700
PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs
More informationMADRIX NEO Quick Start Guide & User Manual
MADRIX NEO Quick Start Guide & User Manual 4 th Edition, Last Update: March 2011 Thank You for Purchasing MADRIX NEO Please read this manual carefully and thoroughly before using the MADRIX NEO. Make sure
More informationHow To Use A Ves-0116 Video Splitter With Audio And Video From A Computer Or Tv Aten (Ves-116)
User Manual VS-0116 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them. This package
More informationVCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet
VALIANT COMMUNICATIONS LIMITED VCL-PRI ISDN Primary Rate (Euro-ISDN) Multiplexer Product Brochure & Data Sheet 1 INDEX S.No. Particulars Pg. No. 1. Product Overview - VCL-PRI ISDN (Euro ISDN Multiplexer)
More informationInstallation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08 Contents Introduction.... Key Features... Unpacking and Inspection....3 Product
More informationPrisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters
Prisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters Mini Media Converters The Prisma Mini Media Converter measures less than 3.5 inches deep and 2 inches wide, and
More information************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D
************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D INTRODUCTION Power Acoustik amplifiers provide high-performance
More informationFIBER OPTIC A/B/C SWITCH (Latching)
JANUARY 2008 Model# SW1004A FIBER OPTIC A/B/C SWITCH (Latching) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days
More informationInnkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio
Innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Introduction Innkeeper PBX will allow you to send and receive audio through your multi-line PBX, ISDN or analog telephone. While this may seem like
More informationUSER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
More informationLwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
More informationDigital T1/E1 PCI (HMP) Board
Digital T1/E1 PCI (HMP) Board Copyright (c) 2010. All rights reserved. Digital T1/E1 PCI (HMP) Board Table of Contents Copyright Information 1 Contacting PIKA Technologies 2 Preface 3 Related Documentation
More informationNI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
More informationHT-150 Owner s Manual
HT-150 Owner s Manual 1 x 5 HDMI to HDBaseT Distribution Amplifier PureLink TM 535 East Crescent Avenue Ramsey, NJ 07446 USA Tel: +1.201.488.3232 Fax: +1.201.621.6118 E-mail: sales@purelinkav.com www.purelinkav.com
More informationVS-0202 VS-0204. User Manual
User Manual VS-0202 VS-0204 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.
More informationWIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
More informationIxia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET
Ixia Director TM Powerful, All-in-One Smart Filtering with Ultra-High Port Density The Ixia Director TM is a smart filtering appliance that directs traffic of interest to your monitoring tools. Now you
More informationKOM200. Industrial Serial to Fiber Media Converter. User s Manual
KOM200 s Manual 200911 KOM200 Industrial Serial to Fiber Media Converter s Manual KYLAND Technology Co., Ltd. 1 KOM200 s Manual 200911 Table of contents CHAPTER 1: PRODUCT OVERVIEW---------------- 3 CHAPTER
More informationQuick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More information