basicdim DGC Compact control module

Size: px
Start display at page:

Download "basicdim DGC Compact control module"

Transcription

1 luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output channels with adjustable offset from channel to channel 1 1 relais output Sensor input for up to DGC sensors 5DPI 1 switch inputs for on/off switching and dimming Individual adjustment of the parameters with DGC Programmer or software mastercfigurator 5-ear guarantee È Wiring diagrams and installation examples, page 9 1

2 luxctrol lighting control sstem DGC Compact control module Technical data Rated suppl voltage 0 0 V Mains frequenc 50 / 0 Hz Power.5 W Stand-b power 0.5 W Operating temperature C Storage temperature C Tpe of protection IP0 Max. casing temperature tc 0 C Ordering data Tpe Article number Mounting Packaging carton DGC Luminaire installation 10 pc(s). Specific technical data Tpe Inputs Outputs CH as Link Line Output, rela (L ) Dimming Max. cable Max. Max. sensor Digital control Control output Dimming Maximum Voltage DC Maximum Number of Max. switching Maximum Max. switch length at DGC sensors line length at line LI/DSI per phsical range cable length cable length combinable output (e.g. apparent switching 1.5 mm² mm² output (devices) at 1.5 mm² at 1.5 mm² modules ) power output DGC double 100 m 10 m % 100 m 1 V 100 m VA 500 W

3 luxctrol lighting control sstem ACCES- SORIES DGC Sensor 5DPI 1f Product description Light measurement and motion detection Up to DGC sensors on one DGC Can be remote controlled Light measurement and motion detection can be deactivated Individual adjustment of the parameters with DGC Programmer or software mastercfigurator Power suppl via DGC Technical data Ø of detection range, mounted at a height of.5 m m Swivel design no Detection angle 0 Light measurement at the sensor head lx Infra-red control range 5 m Max. mounting height 5 m Operating temperature C Storage temperature C Tpe of protection IP0 1 The measured value at the sensor head corresponds to approx. 15 to,000 lux on the surface measured. 1,8, Ø1,9 1,9 1, Ordering data Tpe Article number Packaging, carton Sensor 5DPI 1f Luminaire installation pc(s).

4 luxctrol lighting control sstem ACCES- SORIES DGC Sensor 5DPI 1rc Product description Light measurement and motion detection Up to DGC sensors on one DGC Can be remote controlled Light measurement and motion detection can be deactivated Individual adjustment of the parameters with DGC Programmer or software mastercfigurator Power suppl via DGC Technical data Ø of detection range, mounted at a height of.5 m m Swivel design no Detection angle 0 Light measurement at the sensor head lx Infra-red control range 5 m Max. mounting height 5 m Operating temperature C Storage temperature C Tpe of protection IP0 5,5 5, 1 The measured value at the sensor head corresponds to approx. 15 to,000 lux on the surface measured. Ø,5 Ø58 18 Ordering data Tpe Article number Packaging, carton Sensor 5DPI 1rc Ceiling installation pc(s).

5 luxctrol lighting control sstem ACCES- SORIES DGC Programmer Product description Optional infra-red programming unit for DGC Setting of predefined discrete parameter values Programmable functions such as light level, time dela, P.I.R., bright-out, power up Ordering data Tpe Article number Dimensions L x W x H Packaging carton DGC Programmer x 5 x 15 mm 1 pc(s). ACCES- SORIES REMOTECTROL IR Product description Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activation of automatic lighting control Setting the threshold control point (Set button) Ordering data Tpe Article number Dimensions L x W x H Packaging carton REMOTECTROL IR x 0.5 x. mm 500 pc(s). 5

6 luxctrol lighting control sstem ACCES- SORIES Strain-relief set Product description 5-ear guarantee 1 50 Ordering data Tpe Article number Packaging carton Strain-relief set pc(s).

7 luxctrol lighting control sstem DGC The basic DIM DGC provides the basis for an eas-to-use and cost-effective lighting sstem with motion detection. When the sensor detects movement it triggers a individual adjustable motion detection profile in the control unit. As the amount of natural ambient light changes the illuminance from the artificial lighting sstem is adjusted. The connected luminaires can be switched on and off via momentar-action switch or remote control possible. The LI IN interface allows integration of the DGC module also into a comfortdim sstem. The DGC module has 5 preprogrammed profiles which can be selected using the DGC Programmer. The profiles can be adjusted to our application via the mastercfigurator ( V.1) software. If the DGC module is used in the basic application, the CH can be used as control channel for controlling subordinate DGC modules (basic connection), so that the controlling and the subordinate DGC modules can be programmed and allocated to groups using the mastercfigurator software. Ever single DGC module can be allocated to a group and respond to the presence of up to 5 groups (for more detailed information please refer to the mastercfigurator documentation). Standards EN EN EN 1-1 EN EN 15 EN EN EN 9 Glow-wire test according to EN 1-1 passed. LI standard The DGC is designed to control control gear with LI standard IEC 099 (LI V0) and IEC 8 (LI V1). Installation DGC can be operated without sensor. The motion detection must be disabled via mastercfigurator or with unique connecting a sensor and DGC Programmer. DSI/LI is not SELV. The installation instructions for mains voltage therefore appl. The maximum cable length between the external switch and DGC is 100 m. The maximum cable length between the sensor and DGC is 10 m. A snchronous operation of LI and DSI ballasts at the same control gear is not possible. The output channels (for a cable cross-section of 1.5 mm ) must not be exceeded 100 m. If CH is used as link line, the maximum cable length must not exceed 100 m (at 1.5 mm²). If a DGC is connected to CH, LI IN is disabled and CH is used as Link-Line (neighbourhood function). No control commands are transmitted via CH, to reactivate LI IN see DGC manual. An number of push to make switches ma be connected in parallel to the inputs. Do not connect standard switches to the input. Please ensure that the detection range of the sensor lies in the lighting area of the controlled luminaires. Heaters, fans, printers and copiers located in the detection zone ma cause incorrect presence detection. To avoid false readings, the sensor should be installed so there is no direct light from the lamp in the detection zone. Sensor wires must be routed separatel from the lamp wires and mains cables otherwise the lighting control sstem ma malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used.

8 luxctrol lighting control sstem DGC sensor Light level recognition area Presence / motion detection Sensor alignment x Example for light and motion detection area at height of 1. m: x x1 x1 1 m α x = α x1 = 8 α = 0 h α = 8 h h 0. m x x1 1. m 8 Light level recognation area x x x1 x1 x 1 m Presence / motion detection.8 m d x1 h * x1 x d 1. m 1. m 0. m 1.0 m.8 m.0 m 1. m 0.8 m 1. m. m. m 1.8 m 0.9 m 1. m. m.5 m.0 m 1.0 m 1. m.0 m. m.1 m 1.1 m 1. m. m.0 m. m 1. m 1. m.9 m.5 m. m 1. m.0 m 5. m.0 m.1 m 1. m. m.5 m * The recommended maximum room height for office applications is m and for corridor applications for example m. Up to m mounting height presence is detected and over m motion is detected. Calculation of the diameter (light area): x1 = tan(ax1) h x = tan(ax) h = tan(a) h Calculation of the diameter (motion area): d = tan(0,5 a) h Mounting variants luminair installation sensor Size of the sheet: mm Size of the sheet: mm 1,5,5 19,1 ø1,1 +0, 0, +0, 0 +0, ,1-0,1 ø1,8 +0,1 0, 0-0,15 Size of the sheet: mm, 5,5 1,1 +0, 0 1,1 +0, 0 R1,9 0-0, 8

9 luxctrol lighting control sstem Wiring diagram DGC LI L N DGC Sensor * L N L LI IN max. 500 W (L') max. DGC e Sensor ed CH1 D CH D max. DGC * must be the same phase as for L basic L N DGC Sensor max. * L N L ** LI IN DGC e Sensor ed *** CH1 D CH D DGC Sensor LI USB * L N L ** LI IN DGC e Sensor ed CH1 D CH D max. * must to be the same phase as for L ** can be connect with loads up to 500 W, as shown in the wiring for LI *** if a DGC is connected to CH, LI IN is disabled and CH is used as Linke-Line (neighbourhood function). No control commands are transmitted via CH, to reactivate LI IN see DGC manual. 9

10 luxctrol lighting control sstem Relais in standb L N L DGC Sensor The inrush currents of the control gears must be taken into account when dimensioning the contactor. * L N L LI IN DGC e Sensor ed CH1 D CH D max. max. DGC * must be the same phase as for L Wiring tpe and cross-sections for DGC Solid wire with a cable cross-section of 0.5 mm² to 1.5 mm². wire preparation: mm² mm LI IN The LI IN interface allows integration of the DGC module also into a comfortdim or other BMS sstems. However, not all LI commands are supported. The LI commands supported are listed in the operating instructions. B using the DGC in basic configuration (additional DGC s connected to CH) LI IN interface will be deactivated. Wiring tpe and cross section Sensor 5DPI 1rc The wiring can be solid wire or stranded wire with a cross-section of 0. mm² to 1.5 mm². wire preparation: mm² mm Wiring tpe and cross section Sensor 5DPI 1f The wiring can be solid wire or stranded wire with a cross-section of 0. mm² to 0.5 mm². wire preparation: mm² LI/DSI output channels CH1 - CH The output channels can be set to DSI or LI (default) using the DGC Programmer or the mastercfigurator software. After mains failure the DGC will set new the following parameters to CH1/CH: POWER LEVEL SYSTEM FAILURE LEVEL FADE TIME MIN LEVEL MAX LEVEL For more detailed information please refer to the manual mm 10

11 luxctrol lighting control sstem Switch DGC has two inputs ( and ) for two external switches. An number of switches can be connected in parallel to the inputs (parallel connection of and possible). Short press (< 500 ms): Long press (> 500 ms): / Dim up/down A change in the light value deactivates lighting regulation onl temporaril. As soon as the luminaire has been automaticall switched on again (motion detection) or manuall switched off and on again, regulation is activated again. x short press: The overwritten setpoint light value is stored (luminaire acknowledges b flashing twice) Function is lockable via the DSI programmer Different output channels are controlled, depending on the profile selected. Relais The rela can be used in four different operating modes: Reduction of standb losses (standb wiring example) Independent output channel for switching non-dimmable luminaires (LI wiring example) Depending on the profile used, the rela will respond differentl. For the 5 main profiles, the two rela profiles used are Standb and Onl. The mastercfigurator software allows to enable or disable the rela profiles as well. Standb Onl Standb Onl Energ saving mode If the DGC module is switched off, the rela will switch off (after 10 minutes). If the DGC is switched on, the rela will switch on. Switching: rela in standb mode The rela must be switched on using the momentar-action switch, but is switched off b the presence detector. Active Inactive The rela is switched on or off via the presence detector. The rela must be switched on and off using the momentar-action switch. 11

12 luxctrol lighting control sstem Depending on the profile used, different operating modes are preprogrammed for the presence detector. These can be changed using the DGC Programmer or the mastercfigurator software. onl Run-on time / Onl Never 1min 10min 0min AUTO CH CH1 0 % 0 % The light is switched on and off automaticall based on the presence/absence of people. The presence detector just switches the connected luminaires off. The luminaires are switched on manuall via the connected external momentar-action switch or the remote control. If no presence is detected, the sensor dims down to the second light level parameter and maintains this setting. Presence detector disabled. The light must be switched on and off manuall. Run-on time of the presence detector, run-on time starts when no presence is detected. The run-on time ma var depending on the profile used. You can choose whether ou want the DGC module to switch off the light completel or to dim it down to the absence value after the run-on time. It can also be changed using the DGC Programmer or the mastercfigurator software. Absence value 1% 10% 0% Switch-off dela 0min 1 min 0min The absence value (light level) and the switch-off dela (the period for which the level is maintained) differ depending on the profile used; these parameters ma be changed using the DGC Programmer or the mastercfigurator software. Offset - 0% Depending on the profile used, a negative offset ma be enabled between CH and CH1. Using the DGC Programmer and the mastercfigurator software, this parameter ma be changed (also positive offset possible). 500 LUX Artificial light Natural light Manual-off dela 1min Set target value SET The light level can be set via following options: REMOTECTROL IR (press the ke for > s) DGC Programmer (press the ke for > s) mastercfigurator software external momentar-action switch: SET B briefl pressing the momentar-action switch twice the currentl measured light level is saved as new target value. (Depending on the profile used, this function is enabled or disabled, but it can be changed using the DGC Programmer or the mastercfigurator software) Bright-out If the nominal illuminance level (e.g. 500 lx) is exceeded for 10 minutes at over 150 % (e.g. 50 lx), the light is switched off, even if presence is detected. The light is switched on again as soon as the measured light level falls below the target value. Depending on the profile used, this function is either enabled or disabled and can be changed using the DGC Programmer or the mastercfigurator software. The bright-out status can be indicated on the sensor b a slowl flashing green status LED. B default this function is disabled, but it can be enabled using the mastercfigurator software. CH1 CH 10 min If the light is switched off manuall via momentar-action switch or remote control, the presence detector is disabled. After a period of dela without an presence detected, the presence detector is enabled again. If the sensor detects presence during the Manual Off dela, the dela time will start all over again. Lighting control AUTO Lighting control is started via the Auto ke of the Programmer or REMOTECTROL IR. If the DGC module has been switched on via the ke, lighting control is disabled. If ou want to use lighting control, ou need to start the DGC module via the Auto ke. Lighting control can also be disabled using the mastercfigurator software. Light control incl. brightout activated for CH1. CH is not illuminated controlled. 1

13 luxctrol lighting control sstem Neighbourhood function Depending on the profile used, the DGC can respond to presence detected in other groups. These functions can be changed using the DGC Programmer or the mastercfigurator software. Switched off Switched on No response to presence detected in other groups. Default setting for all profiles! If presence is reported b other groups, the light level will switch to presence value Behaviour after return of power The DGC module features two different tpes of starting behaviour after mains failure. Power behaviour (luminaires remain switched off) Power behaviour (the luminaires are switched on after return of power). Default setting for all profiles! Switched on If presence is reported b other groups, the light level will switch to absence value Momentar-action switch inputs Momentar-action switch 1 Momentar-action switch CH1 CH CH1 CH Displa of outputs controlled b momentaraction switch (CH1 and CH, or just CH1 or CH) Basic functions Switching on If the DGC module has been switched on via, lighting control is disabled. Switching off Dimming up Dimming down Profiles Profile 1: Individual room Profile : Classroom Profile : Corridor Profile : WC Profile 5: Free-standing luminaire (default profile) Profile Test: You ma use the Profile Test to check the profile ou selected. All times relevant to the profile are reduced to 15 s. The Profile Test will automaticall be terminated after 1 h, or b pressing the Auto ke of the DGC Programmer. The profiles can be adjusted to our needs via the mastercfigurator software or the DGC Programmer. For more detailed information please refer to the mastercfigurator documentation at 1

14 luxctrol lighting control sstem Brief description of profiles Individual room profile CH1 CH SET Standb - 0% Onl - 0% Standb Onl CH1 CH 10min 10% 0min 10 min 1 min 10% 0min 1 min 10min 10% 1 min 10 min 1 min 1 min 10 min SET Classroom profile CH1 CH onl Corridor profile CH1 CH CH1 CH CH1 CH WC profile Free-standing luminaire profile (default) CH1 CH SET Standb CH1 CH SET 1

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

Operating instructions II / 2004

Operating instructions II / 2004 Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)

More information

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output

More information

Operating instructions IV / 2007

Operating instructions IV / 2007 General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5 E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 100 W Suitable

More information

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5 EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

Busch-Watchdog Presence EIB Type: 6131-74-102-500

Busch-Watchdog Presence EIB Type: 6131-74-102-500 Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value

More information

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP10425844)

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP10425844) In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. 6 TEST

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

EBDSPIR-DD, EBDSPIR-DD-IP

EBDSPIR-DD, EBDSPIR-DD-IP Product Guide EBDSPIR-DD, EBDSPIR-DD-IP Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer

More information

EBDSPIR-PRM, EBDSPIR-PRM-IP

EBDSPIR-PRM, EBDSPIR-PRM-IP Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series Udriver LCAI 35W 350mA 900mA ECO C ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 900 ma Max. output power 35 W Nominal

More information

LED control gear. LED control gear

LED control gear. LED control gear Overview System overview Product overview compact Product overview linear / area Product overview constant voltage / constant current Product / function matrix Page 10 Page 12 Page 13 Page 14 Page 15 Compact

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes

More information

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60. General information. Overview. Set language

Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60. General information. Overview. Set language Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60! Safety notes GB This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

KNX Lighting Control System

KNX Lighting Control System KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting

More information

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000 Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Lighting Management solutions

Lighting Management solutions Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

Transmitter Actuator 230V wave UP 560. Operation

Transmitter Actuator 230V wave UP 560. Operation Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE Wespot SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE EN This manual is published by OPTEX, without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE Uengine STARK DLE PREMIUM system data sheet STARK DLE Product description Tunable white system with adjustable colour temperature along the planck s curve from 2.700 to 6.500 K NEW LI DEVICE Type 8 for

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Operating instructions

Operating instructions Operating instructions DALI BASIC lighting control system Type: DALI RC BASIC SO OSRAM GmbH Hellabrunner Str. 1 D 81536 Munich Tel.: +49 89 6213 0 Fax: +49 89 6213 2020 Customer Service Center (KSC) Germany

More information

PART 1 PRODUCT (GENERAL)...1.

PART 1 PRODUCT (GENERAL)...1. TABLE OF CONTENTS PART 1 PRODUCT (GENERAL)...1. 1.1--PRODUCT INTRODUCTION...1. 1.2--PRODUCT FEATURES...1. 1.3--TECHNICAL SPECIFICATIONS...2. 1.4--PHOTOMETRIC DATA...3. 1.5--SAFETY WARNING...4. PART 2 INSTALLATION...5.

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

SZI 1029. IR Audio Transmission Technology Modulators/Radiators

SZI 1029. IR Audio Transmission Technology Modulators/Radiators General Description The is a 5-W high-power radiator for use with all wideband and narrowband modulators. The radiator is automatically switched on by the RF carrier and can cover areas of up to 800 m

More information

DALI Driver Configurator User Guide

DALI Driver Configurator User Guide 1 (5) DALI Driver Configurator User Guide IC COLOUR CONTROL Intelligent Colour (ic) is Helvar s solution for LED drivers and lighting control systems supporting DALI device type 8 functionality for colour

More information

Industrial Linergy LED

Industrial Linergy LED Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Actuator for modulating control AME 435

Actuator for modulating control AME 435 Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.

More information

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted

More information

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR This Block Occupancy Detector recognises the current drawn by moving trains within a block, and can operate a number of built-in programs

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

Medical Lighting. XL4 Patient Light

Medical Lighting. XL4 Patient Light Medical Lighting XL4 Patient Light The XL4 is the new ergonomically designed, energy efficient patient light from EDL Lighting Limited. Its purpose is to cover a spectrum of applications within the Healthcare

More information

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes Dynamic

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10 ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Electrical connection

Electrical connection (I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

STERILIZERS, LABORATORY DRYING OVENS

STERILIZERS, LABORATORY DRYING OVENS TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and

More information

Unica for KNX system 226

Unica for KNX system 226 Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from

More information

Controlers. Controler

Controlers. Controler s 4 INDEX Controlers Color Wheel LED Remote page 4 Push Button RGB Controler page 5 Dimmable LED Power Supplies page 6 DMX Controler Sunlite STICK 2 page 7 DMX Controler Sunlite STICK-GA2 page 8 DMX Controler

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information