THE GUIDE FOR CANTERBURY BUILDERS BELOW-FLOOR WORK
|
|
|
- Emma Lindsey
- 10 years ago
- Views:
Transcription
1 TE GUIDE FOR CANTERBURY BUILDERS BELOW-FLOOR WORK [Your new best friend]
2 About this booklet This booklet, Below-Floor Work, and its companion booklet Above-Floor Work, are for builders and others wanting an overview of requirements for repairing and rebuilding houses in the Canterbury Green Zone. They outline the regulatory requirements for builders, and highlight special issues for working in the Canterbury Green Zone. These booklets are an introduction to the more detailed guidance published by the Ministry of Business, Innovation and Employment (MBIE): Repairing and rebuilding houses affected by the Canterbury earthquakes (MBIE Guidance). Links are provided to the MBIE Guidance, which should be referred to for more detailed information. BELOW FLOOR Work: FOUNDATIONS FOR TIMBER STRUCTURES If you re building in Canterbury...this is important! Repairing a post-earthquake building is different from carrying out day-today repairs. Floor structures may have been twisted, wrenched, cracked or tilted so much that their repair, relevelling or replacement must be considered before any other repairs are done. In most cases, decisions regarding any earthquake repairs on houses in Canterbury will be made by a Project Management Office (PMO), designer, or engineer. They will engage builders on behalf of the building s insurers or owners to undertake those repairs under usual building contract terms and conditions. BUILD IT RIGT CANTERBURY The groundwork for good decisions. Disclaimer: This document is a guide only. It should not be used as a substitute for legislation or legal advice. The Ministry of Business, Innovation and Employment is not responsible for the results of any actions taken on the basis of information in this document, or for any errors or omissions. Crown Copyright 2013 This booklet, Below-Floor Work, is an introduction to MBIE s guidance for repairing or replacing foundations and gives links to more detailed information. MBIE published the guidance Repairing and rebuilding houses affected by the Canterbury earthquakes to support a quality rebuild in Canterbury. It is available at The MBIE Guidance can be viewed online BELOW-FLOOR WORK APRIL
3 What this booklet covers The booklet sets the scene for building in Canterbury s Green Zone and gives an overview of the nuts and bolts of below-floor work. It covers the repair and replacement of foundations for residential properties that are mainly: One or two storey timber-framed dwellings Located on sites on the flat in Canterbury s Green Zone. It also covers garages and outbuildings, and gives tips for installing new services. Refer to MBIE Guidance Introduction and Part C, section 11 Introduction to TC3. Alert: The companion guide, ABOVE-FLOOR WORK, COVERS repairs to the rest of the building (including chimneys and retaining walls). It is important that foundations and ground floors are repaired or replaced BEFORE starting any above-floor repair or rebuilding. Alert: Repairing or rebuilding earthquake-damaged houses may involve specific engineering design. There is more information under Specific Engineering Design when it is required, and TERE IS more detail PROVIDED in the MBIE guidance. CONTENTS SETTING TE SCENE Building in the Canterbury Green Zone 5 NZ Regulations 9 TE NUTS AND BOLTS Below-floor work 14 Assessing house foundations 14 Confirming the site s Technical Category (TC) 15 Assessing foundation damage repair or replace? 16 Checking ground height requirements 18 Repairing and relevelling foundations in TC1 and TC2 20 Lifting and relevelling floors: all foundation types 21 Relevelling Type A foundations: timber floor with piles 22 Relevelling Type B foundations: timber floor with piles and perimeter foundation 26 Relevelling Type C foundations: concrete slab-on-ground 26 Putting in new foundations 28 Other useful information 37 2 BELOW-FLOOR WORK APRIL
4 SETTING TE SCENE. Building in the Canterbury Green Zone Lessons learned from building performance in the Canterbury earthquakes have led to some improvements in the way houses are designed and constructed. Generally, house framing and bracing performed well; especially for housing sites on the flat. In most cases there was only minor structural damage, along with damage to finishes, services, and site works. owever, the performance of some house foundations on flat sites was less successful, mainly due to liquefaction, stretching over the building footprints (lateral spreading), and tilting of floors (differential ground settlement). So, more attention is being paid to ground conditions and foundation design. The Technical Categories or TCs The main changes that affect repairing and rebuilding houses damaged in the Canterbury earthquakes relate to the land s Technical Category. Flat areas of the Canterbury Green Zone are divided into three Technical Categories, or TCs. NOTE: These categories provide a guide to the level of site investigation required and the appropriate foundations for the house. 4 BELOW-FLOOR WORK APRIL
5 Each property is listed in one of the following: TC1 is where land damage from liquefaction is unlikely in future large earthquakes. Standard residential foundation assessment and construction is appropriate. TC2 is where liquefaction damage is possible in future large earthquakes. Shallow ground investigations may be required when repairing or replacing foundations. There are foundation repair and rebuild options in the MBIE Guidance. TC3 is where liquefaction damage is possible in future large earthquakes. Geotechnical engineering assessment may be required to select the appropriate foundation repair or rebuild. For more about the TCs, see MBIE Guidance section Technical scope, and Part C, section 12 Future land performance in TC3. Confirming the TC is an important starting point before doing repairs, especially for foundations. The TC will indicate which recommendations in the MBIE Guidance are best suited for the site. elpful tip: Find out the Technical Category and other land information for residential sites at the CERA website Specific Engineering Design when it is required Specific engineering design is when the design or design method is non-standard (i.e. outside the Acceptable Solution or Verification Method). See page 9 The Building Code and Building Consents. Specific engineering design will usually be done by a Chartered Professional Engineer (CPEng). The MBIE Guidance recommends specific engineering design in a number of circumstances. Examples are: TC3: Designs for new or repaired foundations in TC3 zone generally require specific engineering assessment or design. illside properties: Foundation repairs for hillside properties are likely to be more complex and won t lend themselves to a standard approach. A professional engineer will usually be engaged to advise on the stability, repair or replacement of any foundations for hillside properties. Masonry foundation walls: Repairs to damaged concrete block and brick masonry walls will depend on whether or how the walls are reinforced and the amount of grouting used (some block walls may be only partially filled and double skin brick masonry is usually unfilled). Specific engineering advice is required for assessing damage to unreinforced brick or block masonry walls. NOTE: Minor cracking in reinforced (two-way reinforced) concrete block walls, that are well attached to the surrounding structure, can usually be repaired by grout or epoxy injection and repointing without specific engineering design. More extensive cracking in reinforced and unreinforced walls usually means repairs are not practical and replacement is probably the only option. 6 BELOW-FLOOR WORK APRIL
6 Pole frame structures: Foundation repairs to pole frame structures will need specific engineering design. Refer MBIE Guidance section 7.6 for outlines of typical damage location and repair options for pole frame structures. Alert: Repairing or rebuilding a timber-framed house generally needs specific engineering design if: The building is more than two storeys high OR more than 10 metres above ground The building work involves foundations for sites in the TC3 zone. Specific engineering design will usually be done by a Chartered Professional Engineer (CPEng). NOTE: If a building needs extensive repairs especially if repairs are to its structure, roof, wall cladding, windows or doors a professional engineer, architect or designer will generally be involved. Some useful links: Concrete or concrete block construction: refer to NZS 4229 Concrete masonry buildings not requiring specific engineering design, and to the Cement and Concrete Association of New Zealand s Code of Practice CCANZ CP 01:2011, available at Steel stud construction: refer to the National Association of Steelframed ousing andbook Best practice for design and construction of residential and low-rise steel framing, available at NZ REGULATIONS The Building Code and Building Consents The Building Act 2004 (Building Act) contains provisions that are designed to ensure buildings are safe and healthy to live in. The Building Code (established under the Building Act) sets the performance standards that all building work must meet. The Building Code is divided into clauses (sections) covering each aspect of a building, such as structure, fire and weathertightness. Each Clause of the Building Code has at least one Acceptable Solution or Verification Method (see These are ready-made design solutions, that you can use to comply with the Building Code. owever, these solutions are not mandatory and following them is only one way of complying with the Building Code. ALL building work MUST comply with the Building Code, whether or not it requires a building consent. For more information on the regulatory context for the Canterbury earthquake repairs, refer MBIE Guidance Part B, section 8.2 Regulatory requirements, and Appendix C1 Basis for confirming compliance with the Building Code for new and repaired house foundations in TC3. Work that MUST AVE a Building Consent All new building work will need a building consent, except the minor work covered by Schedule 1 of the Building Act (see next page). Work that must have a Building Consent includes: Repairs or replacement of structural components (however, some minor structural repairs may not need a building consent check with the local building consent authority) 8 BELOW-FLOOR WORK APRIL
7 Repairs or replacement of fire safety parts of a building Replacing materials that have failed to meet the durability requirements of the Building Code, such as a leaking roof or wall cladding that is less than 15 years old. NOTE: repairs or maintenance of materials such as claddings that have failed due to earthquake damage, do not require a building consent. Work that DOES NOT require a Building Consent Some minor building work does not require a building consent this is known as exempt building work. A list of exempt work is contained in Schedule 1 of the Building Act (for more details see below). For building repairs, exempt work generally includes: Repair or replacement of building components or building services using materials that are the same, or comparable, to existing materials Construction, repair or replacement of walls with less than 1.5 metres of retained ground, that are (1) back-filled no higher than the wall, and (2) do not support loads other than the backfilling. See Above-Floor Work Retaining Walls Construction, repairs or replacement of a deck which is less than 1.5 metres from the ground at any point Installation, replacement, or removal of a door or window Non-structural internal alterations and repairs (repairs to internal wall lining used for bracing do not need a building consent) Any other building work which the territorial authority (local council) considers to be exempt (these can be general or case-by-case exemptions under Schedule 1(k) of the Building Act). Alert: For a complete list of work that does not require a building consent refer TO: (BUILDING ACT SCEDULE 1) buildingconsents/exemption.aspx Remember that, even when a building consent is not required, all building work must still comply with the Building Act and the Building Code. What you are legally responsible for If you are carrying out residential building repairs or new building work under a building contract, you are legally responsible for ensuring that the work: Is properly carried out and completed Complies with the agreed contract terms Is suitable for its intended purpose. Alert: These are known as implied warranties for the quality of your work. You cannot contract out of these (see sections 397 and 399 of the Building Act). If you are designing or giving advice on building work, you are also legally responsible for that advice. Builders who both design and carry out repairs to buildings are therefore legally responsible for the work complying with the Building Code. NOTE: It is important for builders to be aware of their legal responsibilities, especially if doing repairs without a Building Consent. Refer to Work that DOES NOT require a Building Consent. GETTING A BUILDING CONSENT IS ONE WAY OF MAKING SURE TE WORK COMPLIES WIT TE BUILDING CODE. 10 BELOW-FLOOR WORK APRIL
8 Restricted Building Work and Licensed Building Practitioners Restricted Building Work, is building work that MUST be carried out by a Licensed Building Practitioner (LBP). It only applies to houses or apartment buildings up to 10 metres in height and excludes mixed use apartments. If you are an LBP You can do Restricted Building Work you are licensed for, relating to: The dwelling s structure, such as work on foundations, framing and bracing Its weathertightness, such as building work relating to windows, doors, roofing, cladding Some fire safety design work. elpful tip: Go to for more about Restricted Building Work and Licensed Building Practitioners. LBPs, once they have completed their part of the Restricted Building Work, must provide a Record of work form confirming which parts of the Restricted Building Work they carried out or supervised. LBPs must give this form to homeowners and the territorial authority (local council). If you re NOT an LBP If you are not an LBP, you can carry out Restricted Building Work UNDER TE SUPERVISION OF AN LBP licensed for the work. You can also carry out: Work not considered Restricted Building Work Work that does not require a building consent Any work on buildings that are not used for living in, such as sheds, stand-alone garages and carports. The nuts AND bolts. AN INTRODUCTION TO GUIDANCE FOR REPAIRING AND REBUILDING OUSES 12 BELOW-FLOOR WORK APRIL
9 below-floor WORK Assessing house foundations This booklet, and the more detailed MBIE Guidance: Repairing and rebuilding houses affected by the Canterbury earthquakes, cover repairs to house foundations on flat sites in Canterbury s Green Zone. First, foundations must be checked for damage to establish what s required to repair or replace them. This includes: Establishing the site s TC and checking visible land damage Assessing foundation damage repair or replace Checking ground height requirements. Alert: This information is provided as context for builders and others interested in the process. Remember that, in most cases, the actual decisions regarding the nature and extent of any earthquake repairs will be made by a Project Management Office (PMO), designer, or engineer. They will in turn engage builders to undertake those repairs on behalf of the building s insurers or owners. Confirming the site s Technical Category (TC) Confirming the TC for a particular site is important to determine repair requirements for any foundation work. The TC for properties can be found at CERA website The MBIE Guidance contains information on matching visible land damage at the site. Also see MBIE Guidance Part A, section 3.3 for more help with this. TC1 should have no surface damage, liquefaction, or land settlement TC2 may have cracks less than 50 mm wide, small amounts of liquefaction, or land settlement less than 100 mm TC3 will be any sites with signs of damage greater than those listed for TC2. TC3 sites require specific engineering assessment. If the visible signs of damage to a property appear greater than its TC, repair work should assessed for: The requirements of the next highest TC and/or Specific engineering design elpful tip: Repairs in TC3 require specific engineering assessment for foundations. Repairs to foundations for hillside properties will generally need expert advice: see MBIE Guidance section 6 for more information. See MBIE Guidance section 3 for full details. NOTE: After specific ENGINEERING investigation, TC3 properties may be found to be suitable for TC2 type foundations. 14 BELOW-FLOOR WORK APRIL
10 Assessing foundation damage repair or replace? For all TC zones: If the damage to existing foundations is within the limits shown in Figures 1 to 3, the foundations can be repaired or relevelled If the damage is greater than that shown, foundation replacement is indicated. F I G U R E : 1 ASSESSING PILES TIMBER FLOOR F I G U R E : 2 WEN TO RELEVEL TYPE A AND B FOUNDATIONS (see pages 21-26) ANY TWO POINTS 2M APART FLOOR STRETC TYPE A & B FLOORS IF IF a b b a b MORE TAN 10mm, or 50mm 100mm MORE TAN 100MM, OR IF STRETC FOR TYPE A FLOORS MORE TAN 50MM, OR IF STRETC FOR TYPE B FLOORS MORE TAN 20MM FLOOR RELEVEL INDICATED FLOOR REBUILD INDICATED PILE IF OUT OF PLUMB GREATER TAN 15mm IN 1M EIGT = REPLACE PILE IF ALL PILES OUT OF PLUMB CECK BRACING AGAINST NZS 3604 F I G U R E : 3 WEN TO RELEVEL TYPE C FOUNDATIONS - CONCRETE SLABS (see page 26) TYPE C FLOORS Refer MBIE Guidance Part A, section 2 Foundation assessment criteria and approaches, Table 2.3 and Figure 2.2 for more detail. IF b more TAN 50mm, AND SERVICES OK FLOOR RELEVEL INDICATED b IF b more TAN 150mm OR SERVICES CAN T BE FIXED FLOOR REBUILD INDICATED 16 BELOW-FLOOR WORK APRIL
11 Checking ground height requirements There may be obligations to raise the building s floor levels, under both the Building Code, and the local council s flood management areas (FMA) provisions in their District Plan. If the building footprint is increased, floor levels may need to comply with the Building Code and FMA levels of the local council. F i g u R E : 4 GRound EIGT CLeaRanceS FOR NEW FoundaTionS Under the Building Code: For new foundations, NZS 3604:2011 sets minimum floor levels above ground (these are summarised in Figure 4) For relevelling of existing floors, it is usually sufficient to bring floors to the highest existing floor level when it s not practical to meet the ground clearance requirements of NZS 3604:2011. Under local council flood management provisions: Minimum floor levels for new or re-built floors, are set for properties in designated flood management areas (FMAs) at risk of regional flooding (search online for Operative Variation 48 or go to or search under Waimakariri District or Selwyn District Plans). 450mm MINIMUM 50mm COVER TO ALL 1.2 TIMBER 175mm TO BARE GROUND 100mm TO PAVING ALERt: New floors may be required to meet both Variation 48 of ChriSTchurch City Council s flood management plan, set under the Resource Management Act, AND requirements of the Building Code. For more about minimum floor levels, see MBie Guidance PaRT A, sections 2.5, 2.6 and Figure 5.3. Also refer to section 8.4 for FLood risk and floor levels. MASONRY VENEER 150mm TO BARE GROUND 100mm TO PAVING 25mm MINIMUM Building insurers, home owners or others may choose to raise floor levels even if it s not required. To do this, they may decide to build new floors or raise existing ones. Setting floor levels above the ground protects the house from localised water entry, protects timber framing from dampness, and allows under-floor access beneath piled floors. There are limits to the depths of imported fill that may be used to raise floor levels. These limits are to avoid overloading the ground: see MBIE Guidance Part A, section BELOW-FLOOR WORK APRIL
12 Repairing AND RELEVELLING foundations in TC1 and TC2 This section gives an overview of some of the work that s likely to be required to repair existing foundations, plus links to the detailed MBIE Guidance. The actual decision-making about the nature and extent of any repairs will generally be done by a Project Management Office, designer or engineer. Repairing foundations in TC1 and TC2 can generally be done without specific engineering design, and requires only shallow ground testing. Some foundation options in TC2 require specific engineering design. Foundation repair in TC3 requires specific engineering input and sometimes deep ground assessment. Existing foundations are usually one of three types: Type A: timber floor with piles only Type B : timber floor with piles and perimeter foundation Type C: concrete slab-on-ground. See MBIE Guidance Part A, section 2.1 Typical dwelling foundation types. A bit about garages and outbuildings A garage that forms part of a house must be repaired as if it is a house. Stand-alone garages and outbuildings that are not attached to a house may be repaired or replaced to: TC1 requirements if in TC1 or TC2 TC2 requirements if in TC3 Lifting and relevelling floors: all foundation types Floor lifting and relevelling options Type A foundations Type B and C foundations Jack floors and repack piles Jack floors and/or inject engineering resin or low-mobility grout beneath foundation and floor slabs ere s a checklist of things to consider when lifting and relevelling floors (for all three foundation types): Remove floor coverings and house contents in areas of lift Set survey equipment for monitoring lift Clear working space around perimeter of building Detach piles from bearers in areas where packing is required and disconnect any attachments such as external steps, decks or pergolas (whether or not you should lift chimney foundations at the same time using resin or grout injection methods should be assessed case-by-case) Detach services if they cannot accommodate lifting heights Apply the chosen lifting method (see Guidance reference below) Reattach or install new services Backfill the ground. Refer MBIE Guidance Part A, section 4.3, Table 4.1 and Appendix A1 for floor levelling techniques. Also see Part A, section 5.7 for dealing with building services. specific engineering design. 20 BELOW-FLOOR WORK APRIL
13 Relevelling Type A foundations: timber floor with piles ere s a checklist of things to consider when relevelling Type A foundations: Check ground bearing capacity to NZS 3604:2011 (conduct test bores to 4 metres where possible) Remove pile coverboards (if any) and any cladding attachments to foundations Disconnect piped services and power, and loosen flexible cables Disconnect pile/bearer connections Progressively relevel floor and install temporary bracing For pile/bearer gaps less than 100 mm, pack with 3.2 timber (see Figures 5A and 5B) For pile/bearer gaps greater than 100 mm, replace piles Replace any piles out of alignment (see Figure 1) Resettle building and connect bearers to piles to NZS 3604:2011 (see figures 5A and 5B) Reattach edge cladding, foundation boards and services. F I G U R E : 5 A PACKING ORDINARY PILES: SEE NZS 3604, SECTION 4 FOR FIXING SELECTION TIMBER PILES 100mm TICKNESS MAX. 2/25 X 1mm STRAPS WIT MIN. 3/ 30 X 3.15 FLAT EAD NAILS TO BEARER AND PILE EAC SIDE BEARER (END GRAIN) 3.2 SINGLE PIECE PACKER OR FOLDING WEDGES, FIXED IN PLACE 5 TIMBER PILE CONCRETE PILES 4mm GALVANISED WIRE AND 3.5 mm GALVANISED STAPLES WERE SOWN TENSIONING STAPLE 3.2 SINGLE PIECE PACKER OR FOLDING WEDGES (DOTTED), FIXED IN PLACE 100mm TICKNESS MAX. (END GRAIN) CONCRETE PILE 22 BELOW-FLOOR WORK APRIL
14 F I G U R E : 5 B PACKING FOR ANCOR PILE: SEE NZS 3604, SECTION 4 FOR FIXING SELECTION F I G U R E : 6 REPAIRING TYPE B PERIMETER FOUNDATIONS (REFER MBIE GUIDANCE FIGURE 4.2A) MINIMUM 300mm SECTION FROM NZS mm MIN. JOIST MINIMUM 600mm STIRRUPS 200 C/C 50mm MIN. 4 No. D16 BARS BEARER 12mm BOLT IN EXISTING BOLT OLE TROUG BEARER AND NEW OLE TROUG PILE 3.2 SINGLE PIECE PACKER OR FOLDING WEDGES, FIXED IN PLACE END GRAIN REPOSITION 12mm BOLT AND 50mm WASERS, OR PROPRIETARY 12 KN OLD- DOWN BRACKETS FIXING JOISTS TO BEARER. ANCOR PILE ELEVATION NEW D16 BARS NEW FOUNDATION 300mm OVERLAP EXISTING FOUNDATION EXISTING FOUNDATION BARS ELEVATION NEW FOUNDATION EXISTING FOUNDATION D16 BARS EPOXY GROUTED 200mm INTO EXISTING CONCRETE mm MINIMUM BELOW-FLOOR WORK APRIL
15 Relevelling Type B foundations: timber floor with piles and perimeter foundation ere s a checklist of things to consider: Check ground bearing capacity to NZS 3604:2011 (conduct test bores to 4 metres where possible) Disconnect piped services and power, and loosen flexible cables Disconnect pile/bearer connections Detach or demolish peripheral attachments such as steps, terraces and decks Progressively relevel perimeter foundation or install new foundation sections (see Figure 6) For pile/bearer gaps less than 100mm, pack with 3.2 timber (see figures 5A and 5B) Inject grout under lifted foundations Resettle building and connect bearers and plates to piles and foundations to NZS 3604:2011 Reconnect services. Relevelling Type C foundations: Concrete slab-on-ground Existing concrete slabs that have partly settled or cracked can be jacked back to level, with grout or resin injected beneath the footing and slab. ere s a checklist of things to consider: Check ground bearing capacity to NZS 3604:2011 (conduct test bores to 4 metres where possible) Disconnect piped services and power, and loosen flexible cables Detach or demolish peripheral attachments such as steps, terraces and decks Progressively relevel foundation while injecting flowable grout beneath the slab, or install new foundation sections Inject grout under lifted foundations Seal exposed cracks (refer Cracks in concrete floors) Re-lay floor coverings and reconnect services. Cracks in concrete floors Most concrete floors will contain some cracks as a result of shrinkage during the concrete s initial curing and hardening. Shrinkage cracks that have not been made worse by the earthquake, will typically not form part of the earthquake repairs. If cracks are the result of earthquake damage, they can be repaired as follows: Cracks less than 1 mm wide: no structural repairs needed, but cracks in reinforced concrete should be sealed where exposed to the weather Cracks 1 mm 10 mm wide: fill with epoxy injection Cracks 10 mm 20 mm wide: fill with grout injection Cracks more than 20mm wide: break out slab along the crack and recast the slab section. See MBIE Guidance Appendix A4 for ways to identify shrinkage cracking and repair cracking, plus information relating to underfloor heating and slab overlays. Any damage to the damp-proof course should be avoided. If this is punctured, it can be repaired with pressure-sensitive tape. Installing new underground services If new underground services are being installed, these should allow for any future ground movements by: Sleeving any piped services through foundations and floor slabs allow a minimum of 60 mm clearance around pipework, and fill with foamed urethane Providing flexible connections to piped services outside the foundations Providing loops or snaking cables for any cabled services in trenches, to allow for future stretch. Examples of flexible connections are the Storm plastics or Plastec range of products. 26 BELOW-FLOOR WORK APRIL
16 Putting in new foundations If the building s existing foundations are so badly damaged they can t be repaired (see Assessing house foundations), new foundations will need to be put in. Acceptable foundation types for each building type will depend on: The site s TC and the type of ground under the building Ground testing Ground testing will need to be carried out as shown in Figure 7, depending on the site s TC. FIGURE 7: GROUND TESTING WO CAN DO IT Floor plan shape Wall and roof cladding weights. For more about the geotechnical investigation needed, see MBIE Guidance Part A, section 3.4 and also Part C, section 13 for TC3. Foundation repairs in TC3 require specific engineering design. For new foundation options, see Part A, section 5.2 for TC1 and TC2, and Part C, section 15 for TC3. (TECNICIAN) TC1 TESTING BY A TRAINED TECNICIAN TO NZS 3604 SECTION 3, INCLUDING TEST BORES AT 3-4m. PLUS IF TEST SOWS PEAT - SPECIFIC ENGINEERING DESIGN REQUIRED (ENGINEER) TC2 TESTING AS FOR TC1 TESTING BY A TRAINED TECNICIAN WIT OVERSIGT BY CPENG (ENGINEER) TC3 DEEP GEOTECNICAL INVESTIGATION BY CPENG (GEOTECNICAL ENGINEER) 28 BELOW-FLOOR WORK APRIL
17 Ground bearing capacities must be a minimum of: 300 kpa for foundations not specifically designed 200 kpa for raft foundations (see MBIE Guidance Part A, section 5.3) OR As determined by specific engineering design. Floor plan shape Some foundation options depend on simple floor plan shapes. Simple square, rectangular or boomerang floor plans allow easier construction, and possible future relevelling of the foundations. Foundation types that require simple floor plans are: Wall and roof cladding weights Light or medium weight claddings are recommended for most new building work. This is because light and medium weight claddings place less stress on a building foundation, making the building more resilient (i.e. perform better) in an earthquake. eavyweight wall or roof claddings should only be used with some foundation systems, as shown in the following charts. The MBIE Guidance Part A, Table 7.2 recommends using lightweight or medium-weight claddings for repairs or new construction work wherever possible. Concrete raft foundations (TC2 and TC3) Surface structures (TC3). These are explained further in the Foundation Options Table on page 32 (also see MBIE Guidance Part A, section 5.3 for more about plan shape limitations). 30 BELOW-FLOOR WORK APRIL
18 Foundation options The foundation options based on the site s TC, ground performance and the building s floor plan are summarised in the chart below (including references to the MBIE Guidance). This should be read in conjunction with the next chart on page 34, which sets out maximum cladding weights for the different TC zones and foundation types. Foundation type (MBIE guidance references) TC1 TC2 TC3 Foundation type (MBIE guidance references) TC1 TC2 TC3 Type A: raised Yes Yes Concrete raft Yes Yes timber floor with Light and foundations Simple piles (to NZS medium- (four options) plan 3604:2011 (MBIE Guidance weight claddings (MBIE Guidance sections 5.3, 5.3.1) shapes sections 5.1, 5.2, 5.3.2) Deep pile foundations Yes Yes Yes Providing Type B: timber floor with piles and perimeter Yes Yes With enhanced (MBIE Guidance section 15.2) there is no global lateral spread foundation (to NZS 3604: 2011) steel reinforcing Site ground improvement Generally not Yes Yes With TC2 (MBIE Guidance sections 5.1, 5.2, 5.3.2) Type C: concrete slab-on-ground (to NZS 3604:2011 and B1/AS1) (MBIE Guidance sections 5.1, 5.2, 5.3.1) Yes (five options) (MBIE Guidance section 15.3) Surface structures (three types) (MBIE Guidance section 15.4) Specific needed foundations (Some restrictions apply) Yes Simple plan shapes (Some restrictions apply) Yes Yes Yes engineering design 32 BELOW-FLOOR WORK APRIL
19 Maximum cladding weights This table sets out the maximum cladding weights for each foundation type and TC zone (see MBIE Guidance Table 7.2). Technical Category Foundation type Wall cladding Maximum recommended weight Roof cladding Maximum recommended weight The following maximum cladding weights are default listings only, which may be increased by specific engineering design Technical Category Foundation type Wall cladding Maximum recommended weight Roof cladding Maximum recommended weight The following maximum cladding weights are default listings only, which may be increased by specific engineering design TC1 NZS 3604 NZS 3604 Type A Concrete floor Timber floor Type A Type B M M L TC2 / TC3 ybrid Timber floor M L Concrete floor M Single storey Two storey L TC2 NZS 3604 Type B (enhanced) Concrete raft (Simple floor layout) Options 1 2 (300mm) 3 4 Single storey M Two storey M Single storey Two storey L L TC3 Deep Piles Site Ground Improvement Surface structures (Simple floor layout) Concrete raft options 2, 4 modified For use with all TC2 foundation options and cladding weights Type 1, 2 M L Type 3 M Single storey Two storey L 1 2 (300mm) 2 (400mm) 3 4 M M M L L L See next page for Key to cladding weights. M L 34 BELOW-FLOOR WORK APRIL
20 Key to cladding weights Wall claddings: Light (L) 30 kg/m2 Medium (M) kg/m2 eavy () kg/m2 Roof claddings: Light (L) 20 kg/m2 eavy () kg/m2 (e.g. timber weatherboards) (e.g. stucco, autoclaved masonry veneer) (e.g. masonry veneer) (e.g. steel roofing or profiled tiles) (e.g. masonry tiles) Other useful Information MBIE s guidance, Repairing and rebuilding houses affected by the Canterbury earthquakes, contains detailed information about the topics discussed in this booklet and also repair and rebuilding work to the house s superstructure. See guidance-on-repairs-after-earthquake Other useful sections in the MBIE Guidance include: Relevelling systems and outline methods (MBIE Guidance Part A Appendix A1) Insurance and regulatory requirements (MBIE Guidance Part B section 8). The companion to this booklet, Above-Floor Work, is also based on the MBIE Guidance. Other relevant publications and links include: TE GUIDE FOR CANTERBURY BUILDERS ABOVE-FLOOR WORK [Your new best friend] Lifting Earthquake Affected Buildings in Christchurch quake/lifting-earthquake-affected-buildings-christchurch.pdf Subdivision investigation requirements Ductile reinforcing in slabs Guidance on garage classification Repair approaches BRANZ Bulletin 548 search at Asbestos management Ministry of Business, Innovation and Employment (MBIE) ikina Whakatutuki MBIE develops and delivers policy, services, advice and regulation to support economic growth and the prosperity and wellbeing of New Zealanders. MBIE combines the former Ministries of Economic Development and Science + Innovation, and the Departments of Labour and Building and ousing. Building consent exemptions exemption.aspx 36 BELOW-FLOOR WORK APRIL
21 Published in April 2013 by Ministry of Business, Innovation and Employment, PO Box , Wellington, New Zealand. This document is issued as guidance under section 175 of the Building Act While the Ministry has taken care in preparing the document, it should not be relied upon as establishing compliance with all relevant clauses of the Building Act or Building Code in all cases that may arise. The document may be updated from time to time and the latest version is available from the Ministry s website at ISBN [ ] (Print) ISBN [ ] (Online)
FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012
FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012 Building and Housing has published technical guidance for foundation repairs and reconstruction for residential properties in green zone Foundation Technical
4.1 General...4.1 4.2 Local repairs (TC1 and TC2)...4.1 4.3 Re-levelling floors (TC1 and TC2)...4.6
GUIDANCE A CONTENTS Part A: Technical guidance Contents 2. Foundation assessment criteria and approaches 2.1 Typical dwelling foundation types...2.1 2.2 Assessing foundation damage...2.2 2.3 Indicator
Property Inspection. 83A Ascot Avenue North New Brighton Christchurch STRUCTURAL REPORT
Property Inspection 83A Ascot Avenue North New Brighton Christchurch STRUCTURAL REPORT March 2013 This document has been prepared for the benefit of Clint Marston. No liability is accepted by this company
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane
19.1 Overview...19.1 19.2 Repair or replace...19.1 19.3 Relevelling... 19.3
GUIDANCE E CONTENTS Part E: Repairing and rebuilding multi-unit residential buildings Contents 17. Introduction 17.1 17.1 Background...17.1 17.2 Scope...17.2 17.3 General principles...17.4 17.4 Regulatory
Development of Guidance Information for the Repair and Rebuilding of Houses Following the Canterbury Earthquake Series
Development of Guidance Information for the Repair and Rebuilding of Houses Following the Canterbury Earthquake Series Graeme J Beattie (1) 1. Principal Structural Engineer, BRANZ Ltd, Private Bag 50908,
Repairing and rebuilding multi-unit residential buildings
Introduction The Ministry of Business, Innovation and Employment (MBIE) has released technical guidance on repairing and rebuilding multi-unit residential buildings in Canterbury. The guidance applies
Technical categories and your property
Technical categories and your property Information about residential green zone technical categories December 2011 Outline of land assessments Assessment of the land is undertaken by a range of organisations
Date, Time and Place: Presented by: Presented to: 22 August 2013, 0900 hrs, Pier 1 The Embarcadero, San Francisco
Date, Time and Place: 22 August 2013, 0900 hrs, Pier 1 The Embarcadero, San Francisco Presented by: Nick Rogers, Mike Jacka, Kate Williams, Sjoerd van Ballegooy and Rick Wentz, Tonkin & Taylor International
Leaky Homes Financial Assistance Package (FAP) Repair plan example
LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended
8.1 Insurance requirements...8.1 8.2 Regulatory requirements...8.3 8.3 Seismicity considerations... 8.12 8.4 Flood risk and floor levels... 8.
GUIDANCE CONTENTS Part : Technical information Contents 8. Insurance and regulatory requirements 8.1 Insurance requirements...8.1 8.2 Regulatory requirements...8.3 8.3 Seismicity considerations... 8.12
GUIDE TO SETTLEMENT OF CANTERBURY FLAT LAND CLAIMS
GUIDE TO SETTLEMENT OF CANTERBURY FLAT LAND CLAIMS April 2013 i Introduction This guide focuses on repair methods for some of the types of land damage that occurred on flat residential land as a result
Information for building owners & building practitioners: Building work that does not require a building consent. Council discretionary exemptions
Information for building owners & building practitioners: Building work that does not require a building consent Exemptions July update 2015 The Building Act has allowed for some specified work to be carried
How To Build A Foundation For A Building Site In Creeper Island
GUIDANCE C CONTENTS Part C: Assessing, repairing and rebuilding foundations in TC3 Contents 11. Introduction to TC3 11.1 Overview... 11.1 11.2 General principles... 11.2 11.3 Scope... 11.4 11.4 Future
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
Part C: Assessing, repairing and rebuilding foundations in TC3 Contents
C 2. FOUNDATION CONTENTS Part C: Assessing, repairing and rebuilding foundations in TC3 Contents 11. Introduction to TC3 11.1 Overview... 11.1 11.2 General principles... 11.2 11.3 Scope... 11.4 11.4 Future
DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES
WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component
The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri
Determination 2009/103 The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri 1. The matters to be determined 1.1 This is a determination under Part 3 Subpart 1 of the
Elevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance
Homeowners Handbook Contents Who is Premier Guarantee? Your Structural Warranty What to look out for in your New Home Running in your New Home DIY and Maintenance Structural Warranty Cover This booklet
Housing New Zealand. Technical Report on the Results of Foundation Repair Trials Conducted following the Canterbury Earthquakes
Housing New Zealand Technical Report on the Results of Foundation Repair Trials Conducted following the Canterbury Earthquakes Compiled by Housing New Zealand in partnership with Southern Response Earthquake
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
PERFORMANCE GUIDELINES
1. Foundation/Basement 17 PERFORMANCE GUIDELINES 1. FOUNDATION/BASEMENT 1.1 Efflorescence on concrete or masonry surfaces Efflorescence is the formation of a white crystalline or powdery deposit on the
Sample Drawing Package for One and Two Family Dwelling Applications
Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx
HOME INSURANCE ASSESSMENT
m pl e HOME INSURANCE ASSESSMENT Sa Street Address, Suburb File. 0000 Date. December 2014 Street Address, Suburb Page 1 of 8 File. 0000 Date. December 2014 Client Name Street Address Suburb HOME INSURANCE
Your home: the next steps
Your home: the next steps Property Address Pack Delivery Date Practical Completion Date Defects Liability Period Finishes Moving Forward Contains useful general guidance for what to do now your earthquake
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Lighthouse Engineering, L.L.C.
Wednesday, August 20, 2014 Lighthouse Engineering, L.L.C. Michael Gandy, P.E. Registered Professional Engineer (TX: 95672) Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website:
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:
When is a Permit Required? The most common types of projects that require permits are: -New Houses or buildings -Room Additions or Expansions -Structural repairs, remodeling and alterations -Accessory
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
Does your new building
Does your new building need electricity? To save you time and money, talk to us early about your power supply. Our equipment will occupy ground space on your property. You need to consider the size and
Chapter. Restoration of Damaged Structures
5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.
Residential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.
STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA
STRUCTURAL ASSESSMENT FOR Full Metal Jacket Building 0 Prince Street, Prepared by: ALPHA CORPORATION (Alpha) 1850 S. Loudoun Street, Suite 200 Winchester, VA 22601 540-723-0704 September 22, 2010 J. Michael
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA College of Marin c/o Swinerton Management & Consulting P.O. Box 144003 835 College Avenue, Building MS-3 Kentfield, California
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
CONTRACTORS: IT S YOUR BUSINESS TO UNDERSTAND THE NEW CONSUMER PROTECTION MEASURES.
CONTRACTORS: IT S YOUR BUSINESS TO UNDERSTAND THE NEW CONSUMER PROTECTION MEASURES. Licensed Building Practitioners skills maintenance If you are a Licensed Building Practitioner (LBP) you can gain skills
RESIDENTIAL ROOF TRUSS INSTALLATION PROCEDURES
RESIDENTIAL ROOF TRUSS INSTALLATION PROCEDURES Construction Safety Association of Ontario, October 2008 Prepared for the Low-Rise Residential Trade Labour-Management Health and Safety Committee CONTENTS
WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION
WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION WorkSafe Guidance Document Fall Protection in Residential Construction Table of Contents Executive Summary... 1 Introduction... 1
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
GUIDANCE. Building work that does not require a building consent. Building Act 2004
GUIDANCE Building work that does not require a building consent Building Act 2004 Third edition 2014 1. INTRODUCTION DOCUMENT STATUS Ministry of Business, Innovation and Employment (MBIE) Hikina Whakatutuki
Homeowner s Handbook
Homeowner s Handbook Congratulations on buying your new home This booklet will provide you with important information on the warranty cover for your new home which has been arranged by your developer.
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
STANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
Statement of evidence of Brett Gilmore (Engineering)
Before the Independent Hearings Panel at Christchurch under: in the matter of: the Resource Management Act 1991 and the Canterbury Earthquake (Christchurch Replacement District Plan) Order 2014 Submissions
City of Fort Smith Building Permit Process Frequently Asked Questions
Question: W ho must obtain a building permit? City of Fort Smith Building Permit Process Frequently Asked Questions Answer: This answer is the same for residential or commercial building. Any owner or
Page & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
Timber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
CHANGES TO HOME INSURANCE
CHANGES TO HOME INSURANCE ESTIMATING REBUILDING COSTS FOR SUM INSURED POLICIES 25 JULY 2013 - PROPERTY INSTITUTE OF NEW ZEALAND WHAT S CHANGING? Home insurance in New Zealand is moving back from unlimited
OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION
OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION Table of Contents Executive Summary... 1 Introduction... 1 Installing
A Guide for the Homeowner/Builder
A Guide for the Homeowner/Builder To repair, alter, add to or construct a new home, carport, garage, sundeck or other work Plus other related information Table of Contents 1. Introduction... 1 2. Building
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
A Homeowner s Guide to Building Permits
A Homeowner s Guide to Building Permits Building Division City of London 300 Dufferin Ave. P.O. Box 5035 London, ON N6A 4L9 Table of Contents What is a Building?... 3 Planning Your Project... 3 When is
Lighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: [email protected] Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses
2 February 2011 Updated 16 March 2011 FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses This fact sheet provides advice for residents about
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
For business. Wiring your business for broadband. What happens when copper is required?
For business Wiring your business for broadband Your cabling requirements are dependent on the size and complexity of your business. Smaller businesses should follow the wiring recommendations for residential
NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE
NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE Conjoint Professor Centre for Infrastructure Performance and Reliability The University of Newcastle Callaghan, NSW, Australia A.W.
Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
How to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
PERGOLAS AND CARPORTS
TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND PERGOLAS AND CARPORTS RECOMMENDED PRACTICE // MARCH 2014 19 This data sheet contains Timber Queensland s recommendations for attached and detached timber
MANUFACTURED HOUSING USED AS DWELLINGS
MANUFACTURED HOUSING USED AS DWELLINGS SECTION AE101 SCOPE AE101.1 General. These provisions shall be applicable only to a manufactured home used as a single dwelling unit and shall apply to the following:
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT
Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide
A guide to plumbing, drainlaying, and gasfitting that does not require a building consent. Superseded. Building Act 2004.
A guide to plumbing, drainlaying, and gasfitting that does not require a building consent Building Act 2004 March 2011 Contents INTRODUCTION 1 Purpose 1 Background 1 SEEKING ADVICE ON EXEMPT BUILDING WORK
Structural Foundation System
Structural Foundation System SLABTEK, a technological advancement in foundation designs for residential and lightweight commercial structures SlabTek is a patent allowed process for concrete foundations
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use
BUILDING/PLUMBING PERMIT APPLICATION REQUIREMENTS
BUILDING BROCHURE BUILDING/PLUMBING PERMIT APPLICATION REQUIREMENTS To ALTER, ADD TO, MOVE or CONSTRUCT a NEW HOME, CARPORT, GARAGE, SUNDECK, or other Building or Structure within the Regional District
BBS/13. Redcliffs 1: Build Back Smarter Case Study
BBS/13 Study A report prepared by Beacon Pathway Incorporated March 2014 About This Report Title Study Authors Lois Easton, Beacon Pathway Inc Reviewers Bill King, Beacon Pathway Inc Abstract The Build
Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996
CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed
PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY
MURRAY SHIRE COUNCIL BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY ADOPTED: 1 May 2012 1 BUILDING OVER OR NEAR WATER AND SEWER MAINS POLICY CONTENTS 1. Objective... 2 2. Requirements for Building Near
Pre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
Residential Building Permit Guide
Residential Building Permit Guide For the Electoral Areas of the Capital Region The purpose of this booklet is to: advise you about the applicable regulations within the Capital Regional District Electoral
symptoms of a faulty foundation
symptoms of a faulty foundation How does drought impact your home's foundation? For many Texas families, their home becomes the single largest investment and also the family fortune. The home's foundation
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
Repair of sheet metal roofs in cyclonic areas
Repair of sheet metal roofs in cyclonic areas Guideline - February 2015 Contents Contents...2 1. Introduction...3 Building approvals...3 What is a building approval?...3 Is a building approval required
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
Land claims are now being settled in Canterbury.
Land claims are now being settled in Canterbury. HERE S A SUMMARY OF THE PROCESS Any damage to the house s foundations is covered by the building claim (not the land claim) Trees and gardens are not covered
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the
Practice Note 2014-62
Practice Note 2014-62 Documentation Required for Applications for Building Permits Reference to the Building Code of Australia (BCA) in this Practice Note means Volume One and Volume Two of the National
A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.
A Solid Foundation Solution for Homeowners from Our products are made with 90% Recycled Material Down. Right. Solid. GREEN. Stop the damaging effects of foundation settling... Sinking foundations, cracked
Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.
TM TM Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. SM The Leading Edge. 10 One Major Causes of foundation settlement or more conditions may
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch
USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and