1 FSAF4(-S) US, FSAF0(-S) US On/Off, Spring Return, Meets 50 F [ C] for Half Hour, 75 Seconds Torque min. 33 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF0(-S) US Power supply FSAF4(-S) US 4 VAC ± 0%, 4 VDC -0% +0% FSAF0(-S) US 0 VAC ± 0%, 50/60 Hz Power consumption FSAF4(-S) US running 7.5 W, 0 VA,.4 A holding W, 4 VA,.5 A FSAF0(-S) US running 50/60Hz: 9.5 W, VA,. A holding 3.5 W, 6 VA,.05 A Transformer sizing 0 VA (Class power source 4V only) Electrical connection motor 3 ft, 8 ga, color coded leads / conduit connectors -S models 3 ft, 8 ga, 4 leads appliance cable / conduit connectors Overload protection electronic throughout 0 to 95 rotation Angle of rotation mechanically limited to 95 Torque 33 in-lb [5 Nm] constant Direction of rotation spring reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 is spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time <75 sec. constant, independent of load spring <0 seconds nominal Humidity 5 to 95% RH non-condensing Ambient temperature normal duty - F to F [-30 C to 50 C] safety duty 3 on/off cycles after 30 minutes at ambient temperature of 50 F [ C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type / IP40 Housing material zinc coated metal Gears permanently lubricated Agency listings culus listed to UL873 and CAN/CSA C. No.4 Noise level (max) 45 db (A) spring return 6 db Servicing Maintenance free Quality standard ISO 900, 5 year Belimo warranty Weight (standard / -S model) FSAF4(-S) US 5.7 / 6. lbs (.6 /.8 kg) FSAF0(-S) US 6. / 6.6 lbs (.8 / 3 kg) Application For two position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft or jackshaft 3/8 to.05 in diameter by means of its universal clamp. A crank arm and mounting brackets are available if the actuator cannot be direct coupled to the jackshaft or damper shaft. Square footage of damper operated will depend on make and model of damper. Typically sq.ft. minimum up to 4 sq.ft maximum will be operated for UL555S applications. Operation The FSAF series actuators provide true spring return operation for reliable fail-safe application and positive close-off on UL555S dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The FSAF series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The FSAF has a manual positioning mechanism which allows the setting of any damper position within its 95 of rotation. The actuator is shipped in the zero fail-safe position to provide automatic compression against damper gaskets for tight shut-off. When power is applied, the manual mechanism is released and the actuator drives toward the open position where it stops rotating. The manual override can also be released physically by the use of a crank supplied with the actuator. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: /" to.05" Optional* 3/8" to 3/4" 3/8" to 5/8" *with K4 US clamp 0.65" [6.5] 3.5" [8.7].4" [57] 0.39" [0] 0.35" [9] 3.86" [98] 0.9" [5] 3.5" [80].64" [67].97" [50] 0.59" [69] 5.85" [48.5] 0.6" [6.5] 004 D0.93" [49] M /0 - Subject to change. Belimo Aircontrols (USA), Inc. FSAF4-S US, FSAF0-S US Auxiliary Switch xspst 7A resistive,.5a inductive at 0V or 50V, UL Approved, double-insulated, one switch at 0, one adjustable from 30 to USA CANADA LATIN AMERICA

2 FSAF0(-S) US, FSAF4(-S) US On/Off, Spring Return, Meets 50 F [ C] for Half Hour, 75 Seconds Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4 US Universal clamp for 3/8 to 3/4 shafts K4- US Universal clamp for up to.05 dia. jackshafts K4-H Universal clamp for hexshafts 3/8 to 5/8 KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF- Crank arm for up to.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF- Tool-0 0 mm wrench ZDB-AF US Angle of rotation limiter ZG-00 Universal mounting bracket ZG-0 Universal mounting bracket ZG-0 Multiple actuator mounting bracket ZG-03 Universal mounting bracket ZG-04 Universal mounting bracket ZG-06 Mounting bracket for Honeywell Mod IV replacement or new crank arm type installations ZG-07 Mounting bracket for Honeywell Mod III or Johnson Series 00 replacement or new crank arm type installations ZG-08 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 00 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit for AF/NF ZG-AF08 Crank arm adaptor kit for AF/NF ZS-00 Weather shield (metal) ZS-50 Weather shield (polycarbonate) ZS-300 NEMA 4X housing mm form fit square shaft adaptor For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAFxx (-S) US actuators, only use accessories listed on this page. Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 4 No ground connection required. Double insulated. 5 For end position indication, interlock control, fan startup, etc., the FSAF4- S US and FSAF0-S US incorporates two built-in auxiliary switches: x SPST, 7A resistive,.5 VAC, UL Approved, one switch is fi xed at 0, one is adjustable from 30 to 90. Meets UL requirements without the need of an electrical ground connection. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Typical Specification Large combination fi re and smoke dampers are to be operated by Belimo FSAF series actuators. Manufacturer shall provide 5 year warranty. Actuators shall draw no more than VA at 0V or 4V. M /0 - Subject to change. Belimo Aircontrols (USA), Inc. Where auxiliary switches are required for signaling, starting fans, or position indication, -S model actuators, damper blade, or proximity switches shall be provided. Smaller dampers shall employ Belimo FSLF or FSNF actuators per damper manufacturer recommendations. FSAF4 US and FSAF0 US W9_08 Auxiliary switch USA CANADA LATIN AMERICA 7

3 FSAF30(-S) US On/Off, Spring Return, 50 F [ C] for Half Hour, 75 Seconds Torque min. 33 in-lb, for control of air dampers Technical Data FSAF30(-S) US Power supply 30 VAC ± 4%, 50/60 Hz Power consumption running 50/60Hz: W, VA,.07 A holding 3.5 W, 6 VA,.03 A Transformer sizing 0 VA (Class power source 4V only) Electrical connection motor 3 ft, 8 ga, color coded leads / conduit connectors -S models 3 ft, 8 ga, 4 leads appliance cable / conduit connectors Overload protection electronic throughout 0 to 95 rotation Angle of rotation mechanically limited to 95 Torque 33 in-lb [5 Nm] constant Direction of rotation spring reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 is spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time <75 sec. constant, independent of load spring <0 seconds nominal Humidity 5 to 95% RH non-condensing Ambient temperature normal duty - F to F [-30 C to 50 C] safety duty 3 on/off cycles after 30 minutes at ambient temperature of 50 F [ C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type / IP40 with fl exible conduit Housing material zinc coated metal Gears permanently lubricated Agency listings culus listed to UL873 and CAN/CSA C. No.4 Noise level (max) 45 db (A) spring return 6 db Servicing Maintenance free Quality standard ISO 900, 5 year Belimo warranty Weight 6.9 lbs (3. kg) Application For two position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft or jackshaft 3/8 to.05 in diameter by means of its universal clamp. A crank arm and mounting brackets are available if the actuator cannot be direct coupled to the jackshaft or damper shaft. Square footage of damper operated will depend on make and model of damper. Typically sq.ft. minimum up to 4 sq.ft maximum will be operated for UL555S applications. Operation The FSAF series actuators provide true spring return operation for reliable fail-safe application and positive close-off on UL555S dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The FSAF series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The FSAF has a manual positioning mechanism which allows the setting of any damper position within its 95 of rotation. The actuator is shipped in the zero fail-safe position to provide automatic compression against damper gaskets for tight shut-off. When power is applied, the manual mechanism is released and the actuator drives toward the open position where it stops rotating. The manual override can also be released physically by the use of a crank supplied with the actuator. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: /" to.05" Optional* 3/8" to 3/4" 3/8" to 5/8" *with K4 US clamp 0.65" [6.5] 3.5" [8.7].4" [57] 0.39" [0] 0.35" [9] 3.86" [98] 0.9" [5] 3.5" [80].64" [67].97" [50] 0.59" [69] 5.85" [48.5] 0.6" [6.5] 004 D0.93" [49] M /0 - Subject to change. Belimo Aircontrols (USA), Inc. FSAF30-S US Auxiliary Switch xspst 7A resistive,.5a inductive at 0V or 50V, UL Approved, double-insulated, one switch at <0, one adjustable from >30 to USA CANADA LATIN AMERICA

4 FSAF30(-S) US On/Off, Spring Return, 50 F [ C] for Half Hour, 75 Seconds Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4 US Universal clamp for 3/8 to 3/4 shafts K4- US Universal clamp for up to.05 dia. jackshafts K4-H Universal clamp for hexshafts 3/8 to 5/8 KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF- Crank arm for up to.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF- Tool-0 0 mm wrench ZDB-AF US Angle of rotation limiter ZG-00 Universal mounting bracket ZG-0 Universal mounting bracket ZG-0 Multiple actuator mounting bracket ZG-03 Universal mounting bracket ZG-04 Universal mounting bracket ZG-06 Mounting bracket for Honeywell Mod IV replacement or new crank arm type installations ZG-07 Mounting bracket for Honeywell Mod III or Johnson Series 00 replacement or new crank arm type installations ZG-08 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 00 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit for AF/NF ZG-AF08 Crank arm adaptor kit for AF/NF ZS-00 Weather shield (metal) ZS-50 Weather shield (polycarbonate) ZS-300 NEMA 4X housing mm form fit square shaft adaptor For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAFxx (-S) US actuators, only use accessories listed on this page. Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 4 No ground connection required. Double insulated. 5 For end position indication, interlock control, fan startup, etc., the FSAF30-S US incorporates two built-in auxiliary switches: x SPST, 7A resistive,.5 VAC, UL Approved, one switch is fi xed at 0, one is adjustable from 30 to 90. Meets UL requirements without the need of an electrical ground connection. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Typical Specification Large combination fi re and smoke dampers are to be operated by Belimo FSAF series actuators. Manufacturer shall provide 5 year warranty. Actuators shall draw no more than VA at 30V or 0 VA at 4V. M /0 - Subject to change. Belimo Aircontrols (USA), Inc. Where auxiliary switches are required for signaling, starting fans, or position indication, -S model actuators, damper blade, or proximity switches shall be provided. Smaller dampers shall employ Belimo FSLF or FSNF actuators per damper manufacturer recommendations. FSAF4 US and FSAF30 US W439_08 Auxiliary switch USA CANADA LATIN AMERICA 74

5 FSAF4-SR(-S) US Proportional, Spring Return, 4 V, to 0 VDC or 4 to 0 ma control signal Operation at 50 F for limited time per UL555S testing Torque min. 33 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection FSAF4-SR FSAF4-SR(-S) US 4 VAC ± 0% 50/60 Hz 4 VDC ± 0% running 7 W, VA holding 3 W, 5 VA 5 VA (class power source) 3 ft, 8 GA, 4 color coded leads (4V) / conduit connector FSAF4-SR-S 3 ft, 8 GA appliance cable / conduit connector Overload protection electronic throughout 0 to 95 rotation Operating range to 0 VDC, 4 to 0mA Input impedance 00 kω (0. ma), 500 Ω Feedback output U to 0 VDC (max. 0.5 ma) for 95 Angle of rotation mechanically limited to 95 Torque 33 in-lb [5 Nm] constant Direction of rotation spring reversible with cw/ccw mounting The control direction switch is not present. Direct acting only. VDC=Fail-safe position. Position indication visual indicator, 0 to 95 (0 spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time motor <75 sec. constant, independent of load spring < 0 seconds Humidity 5 to 95% RH non-condensing Ambient temperature normal duty - F to F [-30 C to 50 C] safety duty 3 on/off cycles after 30 minutes at ambient temperature of 50 F [ C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type / IP40 Housing material zinc coated metal Agency listings culus to UL873 and CSA C. No Noise level (max) running 45 db (A) Servicing maintenance free Quality standard ISO 900, 5 year Belimo warranty Weight 6.0 lbs (.7 kg.) Application For proportional modulation of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft or jackshaft up to.05 in diameter by means of its universal clamp. A crank arm and mounting brackets are available if the actuator cannot be direct coupled to the jackshaft or damper shaft. The actuator operates in response to a to 0 VDC, or with the addition of a 500 Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. A to 0 VDC feedback signal is provided for position indication or master-slave applications. See Application Bulletin for details. Operation The FSAF series actuators provide spring return operation. There is no reversing switch on the FSAF4-SR. It is direct acting only. A reverse acting signal is required if it must spring open while V signal drives it closed. The torque is asymmetrical giving 80 in-lb drive and 33 in-lb spring. The FSAF resets after being driven or springing closed to the 0 position. There is a possible hysteresis of every 000 changes in signal. This can cause a position shift. It is recommended that power or signal be reset once a week. A manual override winder and locking mechanism is provided. If the manual winder is used when the actuator is powered, the actuator will release and drive closed to reset the 0 degree position. The actuator may not be mechanically parallelled or piggybacked. Each damper section should be controlled by a separate actuator. The wire 5 feedback can be used to parallel up to five additional actuators. If less than. V or greater than 9.9V is given wire 3, actuator drives all the way to the respective end stop. The FSAF uses a DC motor which is controlled by a microchip The actuator may be stalled anywhere during its rotation without damage. If power is removed, the damper will spring closed. Interlocks must be provided as necessary for life safety functions and to shut down fan if required. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: /" to.05" Optional* 3/8" to 3/4" *with K4 US clamp 0.65" [6.5] 3.86" [98] 3.0" [78] 3.5" [80].4" [57] 0.9" [5] 0.39" [0] 0.35" [9].64" [67] 0.59" [69] 5.85" [48.5] 0.6" [6.5].93" [49] D00(old) M /0 - Subject to change. Belimo Aircontrols (USA), Inc. FSAF4-SR-S US Auxiliary switch x SPDT 7A resistive,.5a inductive at 0/50VAC. UL Approved, double-insulated, one set at =+0, one adjustable 30 to 90.97" [50] USA CANADA LATIN AMERICA

6 FSAF4-SR(-S) US Proportional, Spring Return, 4 V, to 0 VDC or 4 to 0 ma control signal Operation at 50 F for limited time per UL555S testing Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4 US Universal clamp for 3/8 to 3/4 shafts K4- US Universal clamp for up to.05 dia. jackshafts K4-H Universal clamp for hexshafts 3/8 to 5/8 KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF- Crank arm for up to.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF- Tool-0 0 mm wrench SGA4 Min. and/or max. positioner in NEMA 4 housing SGF4 Min. and/or max. positioner for flush panel mounting ZG-R0 500 Ω resistor for 0 to 0 ma control signal ZDB-AF US Angle of rotation limiter ZG-00 Universal mounting bracket ZG-0 Universal mounting bracket ZG-0 Multiple actuator mounting bracket ZG-03 Universal mounting bracket ZG-04 Universal mounting bracket ZG-06 Mounting bracket for Honeywell Mod IV replacement or new crank arm type installations ZG-07 Mounting bracket for Honeywell Mod III or Johnson Series 00 replacement or new crank arm type installations ZG-08 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 00 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit for AF/NF ZG-AF08 Crank arm adaptor kit for AF/NF ZS-00 Weather shield (metal) ZS-50 Weather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAF4-SR(-S) US actuators, only use accessories listed on this page. 4 No ground connection required. Double insulated. 5 Only connect common to neg. ( ) leg of control circuits. 6 For end position indication, interlock control, fan startup, etc., FSAF4-SR-S US incorporates two built-in auxiliary switches: x SPDT, 7A resistive,.5a inductive 0/50 VAC, UL Approved, one switch is fi xed at 0, one is adjustable 30 to 90. Meets UL requirements without the need of an electrical ground connection. The ZG-R0 500 Ω resistor converts the 4 to 0 ma control signal to to 0 VDC. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W88_08 Typical Specification M /0 - Subject to change. Belimo Aircontrols (USA), Inc. Proportional smoke, and combination fi re and smoke dampers, shall be controlled by Belimo FSAF4-SR actuators. The control signal shall provide proportional damper control in response to a to 0 VDC or, with the addition of a 500 Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counter clockwise fail-safe operation. Actuator shall open damper in <75 seconds per UL555S and shall spring closed in under 0 seconds. Actuators shall be UL Approved, have a 5-year warranty, and be manufactured under ISO 900 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Actuators with auxiliary switches must be constructed to meet the requirement for double insulation so an electrical ground connection is not required to meet agency listings. Replacement Application The number one equal or better requirement for use as a replacement for obsolete defective motors is the UL555S listing of the Belimo actuator with the damper for the application. The local authority having jurisdiction sets the requirements since UL has stated that they do not regulate replacements. Wiring Diagrams Proportional control W57_08 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Auxiliary switch 3 Actuator may also be powered by 4 VDC USA CANADA LATIN AMERICA 76

7 FSAF4-BAL(-S) US Spring Return, 4 V, 3-Position, 00% Open Override Operation at 50 F for limited time per UL555S testing Technical Data Power supply FSAF4-BAL(-S) US 4 VAC ± 0% 50/60 Hz 4 VDC ± 0% Power consumption running AC 9.5 VA 6.5W DC 6W holding AC 5 VA 3W DC 3W Transformer sizing 0 VA (class power source 4V only) Electrical connection 3 ft, 8 GA, / conduit connector Overload protection electronic throughout 0 to 95 rotation Control signal 4 VAC/DC 3-position Angle of rotation 0 to 95, pot adjustable Torque 33 in-lb [5 Nm] Direction of rotation spring reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time motor <75 50 F [ C] spring < 0 seconds Humidity 5 to 95% RH non-condensing Ambient temperature - F to F [-30 C to 50 C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type /IP40 (with flex conduit) Housing material zinc coated metal Agency listings culus to UL873 and CSA C. No Noise level (max) running <45 db(a) spring <6dB(A) Servicing maintenance free Quality standard ISO 900, 5 year Belimo warranty Weight 5.3 lbs (.4 kg) 5.7 lbs (.6 kg) for -S model FSAF4-BAL-S US Auxiliary switch x SPDT 7A resistive,.5a inductive at 0/50VAC. UL listed, double-insulated, one switch is set at 0, one is adjustable 30 to 90 Application For 3-position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s tests. In the absence of other information, use 0 in-lb of torque per square foot of area for opposed blade and 4 in-lb for parallel blade fire and smoke dampers at 000 fpm air velocity. The FSAF4-BAL is specifically designed to balance the air flow in ducts and simultaneously provide control of fire and smoke dampers. 0V = spring closed. 4V on wire, not 3 = drive to the potentiometer position (balanced flow). 4V on wire 3, regardless of the status of wire = drive full open (smoke control extraction or pressurization). See Application Bulletin for details. Operation For 3-position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s tests. In the absence of other information, use 0 in-lb of torque per square foot of area for opposed blade and 4 in-lb for parallel blade fire and smoke dampers at 000 fpm air velocity. The FSAF4-BAL is specifically designed to balance the air flow in ducts and simultaneously provide control of fire and smoke dampers. 0V = spring closed. 4V on wire, not 3 = drive to the potentiometer position (balanced flow). 4V on wire 3, regardless of the status of wire = drive full open (smoke control extraction or pressurization). SAFETY NOTE The actuator contains no components which the user can replace or repair. Dimensions (Inches [mm]) Standard Optional ½ to.05 ½ 0.65" [6.5] 3.5" [8.7].4" [57] 0.39" [0] 0.35" [9] 3.86" [98] 0.9" [5] 3.5" [80].64" [67].97" [50] 0.59" [69] 5.85" [48.5] 0.6" [6.5].93" [49] pdf M /0 - Subject to change. Belimo Aircontrols (USA), Inc USA CANADA LATIN AMERICA

8 FSAF4-BAL(-S) US Spring Return, 4 V, 3-Position, 00% Open Override Operation at 50 F for limited time per UL555S testing M /0 - Subject to change. Belimo Aircontrols (USA), Inc. Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4- US Universal clamp for up to.05 dia. jackshafts KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF- Crank arm for up to.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF- Tool-0 0 mm wrench ZDB-AF Angle of rotation limiter ZG-00 Universal mounting bracket ZG-0 Universal mounting bracket ZG-03 Universal mounting bracket ZG-04 Universal mounting bracket ZG-06 Mounting bracket for Honeywell Mod IV replacement or new crank arm type installations ZG-07 Mounting bracket for Honeywell Mod III or Johnson Series 00 replacement or new crank arm type installations ZG-08 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 00 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit for AF/NF ZG-AF08 Crank arm adaptor kit for AF/NF ZS-00 Weather shield (metal) ZS-50 Weather shield (polycarbonate) ZS-300 NEMA 4X housing mm form fit square shaft adaptor For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAF4-BAL(-S) US actuators, only use accessories listed on this page. Typical Specification Where indicated on drawings, combination fi re and smoke and balancing dampers shall be controlled by Belimo FSAF4-BAL or equal actuators. The actuators must be designed so that they may be used for either clockwise or counter clockwise failsafe operation. Actuator shall open damper in <75 seconds per UL555S and shall spring closed in under 0 seconds. Actuators shall have a 5-year warranty and be manufactured under ISO900 International Quality Control Standards. Actuator shall have an adjustable Maximum Opening Potentiometer which shall be used by the TAB contractor to adjust fl ow to that portion of the system fed by the damper. The actuator shall spring closed if either the smoke detector or alarm system removes power from it. Actuator shall spring closed if the primary temperature thermodisc opens due to high ambient of >65 F or as otherwise indicted on drawings. The actuator shall drive full open if either the smoke control system 00% open override or Fire Fighters Smoke Control Station override is activated. Damper shall spring closed again if the thermodisc of a combination fi re and smoke damper opens due to high temperature (typically 50 F). Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 4 Only connect Hot, Wire to Wire 3 override control For end position, interlock control, fan start-up, etc., FSAF4-BAL-S incorporates two built-in auxiliary switches: x SPDT, 7A resistive,.5a inductive 0/50 VAC, UL listed, one switch is fi xed at 0, one adjustable 30 to 90 For end position indication, interlock control, fan startup, etc., FSAF4-SR-S US incorporates two built-in auxiliary switches: x SPDT, 7A resistive,.5a inductive 0/50 VAC, UL Approved, one switch is fi xed at 0, one is adjustable 30 to 90. Meets UL requirements without the need of an electrical ground connection. 7 Double insulated WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Line Volts Override control Auxiliary switch 4 VAC Transformer 4 OVERRIDE CONTROL See Wiring Diagrams on following pages for typical methods. S NC S S3 NO S4 NC S5 S6 NO Blk Com Red Hot 3 3 Override Open 6 FSAF4-BAL US 0 30 to 90 FSAF4-BAL-S US _pg _pg USA CANADA LATIN AMERICA 78

9 7074D FSNF4(-S)(-FC) US, FSNF0(-S)(-FC) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Application The type FSNF spring-return actuator is intended for the operation of smoke and combination fire and smoke dampers in ventilation and air-conditioning systems. The actuator will meet requirements of UL555 and UL555S when tested as an assembly with the damper and will open and close in 5 seconds at 350 F. Square footage of damper operated will depend on make and model of damper and the temperature 50 F or 350 F. Operation Mounting of the actuator to the damper axle shaft or jackshaft (3/8 to.05 ) is via a cold-weld clamp. Teeth in the clamp and V-bolt dig into the metal of both solid and hollow shafts maintaining a perfect connection. The specially designed clamp will not crush hollow shafts. The bottom end of the actuator is held by an anti-rotation strap or by a stud provided by the damper manufacturer. The actuator is mounted in its fail safe position with the damper blade(s) closed. Upon applying power, the actuator drives the damper to the open position. The internal spring is tensioned at the same time. If the power supply is interrupted, the spring moves the damper back to its fail-safe position. Subject to change. Belimo Aircontrols (USA), Inc. Technical Data FSNF4(-S)(-FC) US, FSNF0(-S)(-FC) US Power supply FSNF4(-S)(-FC) US 4 VAC ± 0%, 50/60 Hz FSNF0(-S)(-FC) US 0 VAC ± 0%, 50/60 Hz Power consumption running 7 W, 4 VA 4 VAC holding 4 W, 6.5 VA 0 VAC running 9 W, 3 VA, 0.9 A holding 6 W, 8.5 VA, 0.07 A Fusing* FSNF4.5 amp slow blow FSNF0 0.5 amp slow blow Transformer sizing 40 VA per 4 VAC actuator Electrical connection FSNF4 US 3 ft, 8 ga, color coded leads FSNF0 US 3 ft, 8 ga, 3 color coded leads FSNF...-S US 3 ft, 8 ga, appliance cable Overload protection electronic throughout 0 to 95 rotation grounded enclosure, 0V Control microprocessor Angle of rotation 95 Torque 70 in-lb [7.9 Nm] minimum from 3 F to 350 F [0 C to 77 C] Direction of rotation spring can be selected by CCW/CW mounting Position indication visual indicator, 0 to 95 Running time between 3 F and 350 F [0 C to 77 C] <5 seconds at rated voltage and torque Humidity 5 to 95% RH non-condensing Ambient temperature 3 F to F [0 C to 50 C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type Housing material zinc coated steel Gears steel, permanently lubricated Agency listings culus listed to UL873 and CAN/CSA C. No. 4 NYC Department of Buildings Materials and Equipment Acceptance Division MEA M California State Fire Marshal Listing :0 Servicing maintenance free Quality standard ISO 900 Weight FSNF4(-S) US 6.0 lbs [.75 kg], (+ 0.5 lbs [+.3 kg]) FSNF0(-S) US 6.7 lbs [3.0 kg], (+ 0.5 lbs [+.3 kg]) FSNF4-S US, FSNF0-S US, FSNF4-S-FC, FSNF0-S-FC Auxiliary switch xspst 7A resistive,.5a inductive at 0V or 50V, UL Approved, double-insulated, one switch at 0, one at 85 -FC Models have the same electrical and mechanical characteristics except instead of a /" conduit connector a 3/8" screw flex connector is supplied. SAFETY NOTES The actuator contains no components which the user can replace or repair. /" Threaded Connector Screw a conduit fi tting into the actuator s metal bushing. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. 3/8" Flexible Connector Models (-FC Screw Connector) Mount the fl exible conduit into the actuator s metal bushing by means of the provided screw with a torque of 0.9 ft-lb. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: /" to.05" Optional* 3/8" to 3/4" *with K4 US clamp 0.65" [6.5] 3.5" [8.7] 3.86" [98].4" [57] 0.9" [5] 0.39" [0] 0.35" [9] 3.5" [80].64" [67].97" [50] 7.54" [9.6] 0.0" [59] 5.85" [48.5] 0.6" [6.5] ø.6" [ø4.] Accessories All AF/NF linkages and parts except ZG-0 may be employed. * Individual Fusing or Breakers are not required by Belimo. 0.9" [5].93" [49] -S models only.89" [73.5] The FSNF4 draws higher peak current when driving against any type of stop. Given the technology of fuses & breakers, this requires the value of fuse or breaker to be increased to avoid nuisance opening or tripping. A.5 amp slow blow should be used for 4VAC. A 0.5 amp slow blow should be used for 0VAC. Transformers Note that while a 00VA transformer would handle actuators, a 4A breaker is insufficient USA CANADA LATIN AMERICA/CARIBBEAN

10 FSNF4(-S)(-FC) US, FSNF0(-S)(-FC) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Typical Applications Multi-section Damper Assemblies The typical fi re and smoke damper requires from 5-5 in-lb of torque per square foot at 50 F 350 F under dynamic load (400 fpm velocity). The FSNF will operate multi-section dampers using multiple actuators for multiple sections. Some of the methods used are shown below. This is a direct coupled actuator. If linkages are needed use those for the FSAF series. Do not use the ZG-0 as close coupled actuators have a shortened life due to the high speed of the FSNF. Mounting at opposite ends of a jackshaft is OK. Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. For end position indication, interlock control, fan startup, etc., FSNF4-S 4 US and FSNF0-S US incorporate two built-in auxiliary switches: x SPDT, 7A (.5A inductive)@5/50 VAC, UL Approved, 0 and 85. Switch rating is for 50 F / hour only. Single section for one FSNF actuator Blank-off Channel WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Blank-off Channel Wht Blk 4V C H 0V N L Neutral Hot 3 Ground W77 Use of blank-offs between damper sections to provide space for actuator mounting. Large multi-section assembly No ground on 4 V models FSNF4 US FSNF0 US Typical Specification Smoke Control and Combination Fire and Smoke Control Damper Actuators All smoke and combination fi re and smoke dampers shall be provided with Belimo FSTF, FSLF, FSNF, or FSAF actuators. No substitutions allowed. Damper and actuator shall have UL555S Listing for 50 F (350 F) and shall comply with UBC if required by local codes. Where proof of closure switches are required, blade switches, actuator auxiliary switches, or proximity switches are allowed if permitted by local codes. Wht Blk 4V C H 0V N L Gnd Gnd FSNF Multi-Sec ApplicBLK Replacement Applications The number one "equal or better" requirement for use as a replacement for obsolete defective motors is the UL555S listing of the Belimo actuator with the damper for the application. The local authority having jurisdiction sets the requirements. In some cases a permit and inspection may be required. Go to for a Cross Reference from old damper actuators to Belimo. Extensive retrofi t installation instructions are available, along with technical training information. CAUTION Caution must be used when replacing failed motors with new Belimo actuators. Many old motors did not have internal springs and depended on external springs on the side of the damper or wrapped around the damper shaft to close the damper. Old motor springs must be removed or disabled. Do not remove fusible link springs if they had only fi re and no smoke functions Parallel Actuator Wiring No ground on 4 V models W75_08 Subject to change. Belimo Aircontrols (USA), Inc. In some cases, a BAE 65 or equal thermal sensor must be installed. Auxiliary switch wiring for FSNF4-S US, FSNF0-S US USA CANADA LATIN AMERICA/CARIBBEAN

11 C FSNF4(-S)(-FC) US, FSNF30(-S) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Application The type FSNF spring-return actuator is intended for the operation of smoke and combination fire and smoke dampers in ventilation and air-conditioning systems. The actuator will meet requirements of UL555 and UL555S when tested as an assembly with the damper and will open and close in 5 seconds at 350 F. Square footage of damper operated will depend on make and model of damper and the temperature 50 F or 350 F. Operation Mounting of the actuator to the damper axle shaft or jackshaft (3/8 to.05 ) is via a cold-weld clamp. Teeth in the clamp and V-bolt dig into the metal of both solid and hollow shafts maintaining a perfect connection. The specially designed clamp will not crush hollow shafts. The bottom end of the actuator is held by an anti-rotation strap or by a stud provided by the damper manufacturer. The actuator is mounted in its fail safe position with the damper blade(s) closed. Upon applying power, the actuator drives the damper to the open position. The internal spring is tensioned at the same time. If the power supply is interrupted, the spring moves the damper back to its fail-safe position. Subject to change. Belimo Aircontrols (USA), Inc. Technical Data FSNF4(-S)(-FC) US, FSNF30(-S) US Power supply FSNF4(-S)(-FC) US 4 VAC ± 0%, 50/60 Hz FSNF30(-S) US 30 VAC ± 0%, 50/60 Hz Power consumption running 7 W, 4 VA 4 VAC holding 4 W, 6.5 VA 30 VAC running 0 W, 3 VA, 0. A holding 6 W, 8 VA, 0.04 A Fusing* FSNF4.5 amp slow blow FSNF amp slow blow Transformer sizing 40 VA per 4 VAC actuator Electrical connection FSNF4 US 3 ft, 8 ga, color coded leads FSNF30 US 3 ft, 8 ga, 3 color coded leads FSNF...-S US 3 ft, 8 ga, appliance cable Overload protection electronic throughout 0 to 95 rotation grounded enclosure, 30V Control microprocessor Angle of rotation 95 Torque 70 in-lb [7.9 Nm] minimum from 3 F to 350 F [0 C to 77 C] Direction of rotation spring can be selected by CCW/CW mounting Position indication visual indicator, 0 to 95 Running time between 3 F and 350 F [0 C to 77 C] <5 seconds at rated voltage and torque Humidity 5 to 95% RH non-condensing Ambient temperature 3 F to F [0 C to 50 C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type Housing material zinc coated steel Gears steel, permanently lubricated Agency listings culus listed to UL873 and CAN/CSA C. No. 4 NYC Department of Buildings Materials and Equipment Acceptance Division MEA M California State Fire Marshal Listing :0 Servicing maintenance free Quality standard ISO 900 Weight FSNF4(-S) US 6.0 lbs [.75 kg], (+ 0.5 lbs [+.3 kg]) FSNF30(-S) US 6.7 lbs [3.0 kg], (+ 0.5 lbs [+.3 kg]) FSNF4(-S)(-FC) US, FSNF30(-S) US Auxiliary switch xspst 7A resistive,.5a inductive at 0V or 50V, UL Approved, double-insulated, one switch at 0, one at 85 -FC Models have the same electrical and mechanical characteristics except instead of a /" conduit connector a 3/8" screw flex connector is supplied. SAFETY NOTES The actuator contains no components which the user can replace or repair. /" Threaded Connector Screw a conduit fi tting into the actuator s metal bushing. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. 3/8" Flexible Connector Models (-FC Screw Connector) Mount the fl exible conduit into the actuator s metal bushing by means of the provided screw with a torque of 0.9 ft-lb. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: /" to.05" Optional* 3/8" to 3/4" *with K4 US clamp 0.65" [6.5] 3.5" [8.7] 3.86" [98].4" [57] 0.9" [5] 0.39" [0] 0.35" [9] 3.5" [80].64" [67].97" [50] 7.54" [9.6] 0.0" [59] 5.85" [48.5] 0.6" [6.5] ø.6" [ø4.] Accessories All AF/NF linkages and parts except ZG-0 may be employed. * Individual Fusing or Breakers are not required by Belimo. 0.9" [5].93" [49] -S models only.89" [73.5] The FSNF4 draws higher peak current when driving against any type of stop. Given the technology of fuses & breakers, this requires the value of fuse or breaker to be increased to avoid nuisance opening or tripping. A.5 amp slow blow should be used for 4VAC. A 0.5 amp slow blow should be used for 30VAC. Transformers Note that while a 00VA transformer would handle actuators, a 4A breaker is insufficient USA CANADA LATIN AMERICA/CARIBBEAN

12 FSNF4(-S)(-FC) US, FSNF30(-S) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Typical Applications Multi-section Damper Assemblies The typical fi re and smoke damper requires from 5-5 in-lb of torque per square foot at 50 F 350 F under dynamic load (400 fpm velocity). The FSNF will operate multi-section dampers using multiple actuators for multiple sections. Some of the methods used are shown below. This is a direct coupled actuator. If linkages are needed use those for the FSAF series. Do not use the ZG-0 as close coupled actuators have a shortened life due to the high speed of the FSNF. Mounting at opposite ends of a jackshaft is OK. Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. For end position indication, interlock control, fan startup, etc., FSNF4-S 4 US and FSNF30-S US incorporate two built-in auxiliary switches: x SPDT, 7A (.5A inductive)@5/50 VAC, UL Approved, 0 and 85. Switch rating is for 50 F / hour only. Single section for one FSNF actuator Blank-off Channel WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Blank-off Channel W9_08 Use of blank-offs between damper sections to provide space for actuator mounting. Large multi-section assembly Typical Specification Smoke Control and Combination Fire and Smoke Control Damper Actuators All smoke and combination fi re and smoke dampers shall be provided with Belimo FSTF, FSLF, FSNF, or FSAF actuators. No substitutions allowed. Damper and actuator shall have UL555S Listing for 50 F (350 F) and shall comply with UBC if required by local codes. Where proof of closure switches are required, blade switches, actuator auxiliary switches, or proximity switches are allowed if permitted by local codes. Wht Blk 4V C H 30V N, L L, L Gnd Gnd FSNF30 Multi-Sec ApplicBLK_ Replacement Applications The number one "equal or better" requirement for use as a replacement for obsolete defective motors is the UL555S listing of the Belimo actuator with the damper for the application. The local authority having jurisdiction sets the requirements. In some cases a permit and inspection may be required. Go to for a Cross Reference from old damper actuators to Belimo. Extensive retrofi t installation instructions are available, along with technical training information. CAUTION Caution must be used when replacing failed motors with new Belimo actuators. Many old motors did not have internal springs and depended on external springs on the side of the damper or wrapped around the damper shaft to close the damper. Old motor springs must be removed or disabled. Do not remove fusible link springs if they had only fi re and no smoke functions In some cases, a BAE 65 or equal thermal sensor must be installed. Parallel Actuator Wiring No ground on 4 V models FSNF4-S US FSNF30-S US W75_08 Subject to change. Belimo Aircontrols (USA), Inc. Auxiliary switch wiring for FSNF4-S US, FSNF30-S US USA CANADA LATIN AMERICA/CARIBBEAN

13 Subject to change. Belimo Aircontrols (USA), Inc D Technical Data FSLF4(-S)(-FC) US, FSLF0(-S)(-FC) US Power supply FSLF4(-S)(-FC) US 4 VAC ± 0%, 50/60 Hz FSLF0(-S)(-FC) US 0 VAC ± 0%, 50/60 Hz Power consumption running 50/60 Hz, 5 VA 4 VAC holding 50/60 Hz, 3.5 VA end stop 50/60 Hz 5 VA 0 VAC running 50/60 Hz 8 VA holding 50/60 Hz 6.5 VA end stop 50/60 Hz 7 VA Fusing* FSLF4 amp slow blow FSLF0 0.5 amp slow blow Transformer sizing 5 VA per 4 VAC actuator Electrical connection FSLF4 US 3 ft, 8 ga, color coded leads FSLF0 US 3 ft, 8 ga, 3 color coded leads FSLF...-S US 3 ft, 8 ga, appliance cable Overload protection electronic throughout 0 to 95 rotation auto-restart after temporary overload (FSLF0 US grounded enclosure) Control microprocessor Angle of rotation 95 Torque 30 in-lb [3.5 Nm] minimum from 3 F to 350 F [0 C to 77 C] Direction of rotation spring can be selected by CCW/CW mounting Position indication visual indicator, 0 to 95 Running time motor < 5 sec at rated voltage and torque 3 F to + F [0 C to +50 C] spring <5 seconds at rated voltage and torque Humidity 5 to 95% RH non-condensing Ambient temperature 3 F to F [0 C to 50 C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type Housing material zinc coated steel Gears permanently lubricated Agency listings culus acc. to UL60730-A/--4, CAN/CSA E60730-, CSA C. No.4-93 Servicing maintenance free Quality standard ISO 900 Weight FSLF4(-S) US 3.4 lbs [.7 kg], (+ 0.3 lbs [+0.4 kg]) FSLF0(-S) US 4.0 lbs [.8 kg], (+ 0.3 lbs [+0.4 kg]) FSLF4(-S)(-FC) US, FSLF0(-S)(-FC) US Auxiliary switch x SPST 0.5 A inductive, 3A 0/ 50VAC, minimum 5 VDC,.3 A ind,.5a 4VDC, UL listed, 0 and 85. Double insulated FSLF4(-S)(-FC) US, FSLF0(-S)(-FC) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Application The type FSLF spring-return actuator is intended for the operation of smoke and combination fire and smoke dampers in ventilation and air-conditioning systems. The actuator will meet requirements of UL555 and UL555S when tested as an assembly with the damper and will meet requirements of UBC for 5 second opening and closing. Square footage of damper operated will depend on make and model and the temperature required. Operation Mounting of the actuator to the damper axle shaft or jackshaft is via a cold-weld clamp. Teeth in the clamp and V-bolt dig into the metal of both solid and hollow shafts maintaining a perfect connection. The specially designed clamp will not crush hollow shafts. The bottom end of the actuator is held by an anti-rotation strap or by a stud provided by the damper manufacturer. The actuator is mounted in its fail safe position with the damper blade(s) closed. Upon applying power, the actuator drives the damper to the open position. The internal spring is tensioned at the same time. If the power supply is interrupted, the spring moves the damper back to its fail-safe position. SAFETY NOTES The actuator contains no components which the user can replace or repair. 4 VAC Connect via safety isolating transformer, Class supply. /" Threaded Connector Screw a conduit fi tting into the actuator s metal bushing. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. 3/8" Flex Connector (-FC models) Mount the fl exible conduit into the actuator s metal bushing by means of the provided screw with a torque of. Nm. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]).37" [60] 0. [5] 0.45" [] 7.03" [79] 6.8" [73] 5.4" [38]." [8] max 0.79" [0] min 0.5" [.7] 0.75" [9].4" [57] 0.4" [6] 3.86" " [98] *Individual Fusing or Breakers are not required by Belimo. The FSLF4 draws higher peak current when driving against any type of stop. Given the technology of fuses & breakers, this requires the value of fuse or breaker to be increased to avoid nuisance opening or tripping. A amp slow blow should be used for 4VAC. A 0.5 amp slow blow should be used for 0VAC. FSLF0Dims USA CANADA LATIN AMERICA/CARIBBEAN

14 FSLF4(-S)(-FC) US, FSLF0(-S)(-FC) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Typical Applications The typical fi re and smoke damper requires from 5-5 in-lb of torque per square foot at 50 F F under dynamic load (000 fpm velocity). The FSLF is a single section damper actuator. For the multi section dampers, use the FSNF series. This is a direct coupled actuator. If linkages are needed use the FSNF series. Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Single section for one FSLF actuator Two section for two FSLF actuators Typical Specification Smoke Control and Combination Fire and Smoke Control Damper Actuators All smoke and combination fi re and smoke dampers shall be provided with Belimo FSLF, FSNF, or FSAF actuators. No substitutions allowed. Damper and actuator shall have UL555S Listing for 50 F (350 F) and shall comply with UBC if required by local codes. Where proof of closure switches are required, blade switches, actuator auxiliary switches, or proximity switches are allowed. Replacement Applications The number one "equal or better" requirement for use as a replacement for obsolete defective motors is the UL555S listing of the Belimo actuator with the damper for the application. The local authority having jurisdiction sets the requirements. In some cases a permit and inspection may be required. Go to for a Cross Reference from old damper actuators to Belimo. Extensive retrofi t installation instructions are available, along with technical training information. CAUTION Caution must be used when replacing failed motors with new Belimo actuators. Many old motors did not have internal springs and depended on external springs on the side of the damper or wrapped around the damper shaft to close the damper. Old motor springs must be removed or disabled. Do not remove fusible link springs if they had only fi re and no smoke functions In some cases, a BAE 65 or equal thermal sensor must be installed. 3 No ground on 4 V models 4 S4 makes to S6 when the actuator is powered open. For end position indication, interlock control, fan startup, etc., 5 FSLF4-S US and FSLF0-S US incorporate two built-in auxiliary switches. 6 Double insulated WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 4V C=Blk H=Red 0V N=Wht L=Blk Parallel Actuator Wiring 4V C=Blk H=Red 0V N=Wht L=Blk No ground on 4 V models Violet Violet Gray Gray Gnd S S S4 S6 3 4 Common, Neutral Hot 3 Ground FSLF4 US FSLF0 US NC NO Gnd FSLF4-S US FSLF0-S US W0 FSLF0_Parallel_Aux_wiring FSLF0_Parallel_Aux_wiring Subject to change. Belimo Aircontrols (USA), Inc. Auxiliary switch wiring for FSLF4-S US, FSLF0-S US USA CANADA LATIN AMERICA/CARIBBEAN

15 Subject to change. Belimo Aircontrols (USA), Inc D Technical Data FSLF4(-S)(-FC) US, FSLF30(-S) US Power supply FSLF4(-S)(-FC) US 4 VAC ± 0%, 50/60 Hz FSLF30(-S) US 30 VAC ± 0%, 50/60 Hz Power consumption running 50/60 Hz, 5 VA 4 VAC holding 50/60 Hz, 3.5 VA end stop 50/60 Hz 5 VA 30 VAC running 50/60 Hz 7 VA holding 50/60 Hz 6.5 VA end stop 50/60 Hz 7 VA Fusing* FSLF4 amp slow blow FSLF amp slow blow Transformer sizing 5 VA per 4 VAC actuator Electrical connection FSLF4 US 3 ft, 8 ga, color coded leads FSLF30 US 3 ft, 8 ga, 3 color coded leads FSLF...-S US 3 ft, 8 ga, appliance cable Overload protection electronic throughout 0 to 95 rotation auto-restart after temporary overload (FSLF30 US grounded enclosure) Control microprocessor Angle of rotation 95 Torque 30 in-lb [3.5 Nm] minimum from 3 F to 350 F [0 C to 77 C] Direction of rotation spring can be selected by CCW/CW mounting Position indication visual indicator, 0 to 95 Running time motor < 5 sec at rated voltage and torque 3 F to + F [0 C to +50 C] spring <5 seconds at rated voltage and torque Humidity 5 to 95% RH non-condensing Ambient temperature 3 F to F [0 C to 50 C] Storage temperature -40 F to 76 F [-40 C to 80 C] Housing NEMA type Housing material zinc coated steel Gears permanently lubricated Agency listings culus acc. to UL60730-A/--4, CAN/CSA E60730-, CSA C. No.4-93 Servicing maintenance free Quality standard ISO 900 Weight FSLF4(-S) US 3.4 lbs [.7 kg], (+ 0.3 lbs [+0.4 kg]) FSLF30(-S) US 4.0 lbs [.8 kg], (+ 0.3 lbs [+0.4 kg]) FSLF4(-S)(-FC) US, FSLF30(-S) US Auxiliary switch x SPST 0.5 A inductive, 3A 0/ 50VAC, minimum 5 VDC,.3 A ind,.5a 4VDC, UL listed, 0 and 85. Double insulated Application The type FSLF spring-return actuator is intended for the operation of smoke and combination fire and smoke dampers in ventilation and air-conditioning systems. The actuator will meet requirements of UL555 and UL555S when tested as an assembly with the damper and will meet requirements of UBC for 5 second opening and closing. Square footage of damper operated will depend on make and model and the temperature required. Operation Mounting of the actuator to the damper axle shaft or jackshaft is via a cold-weld clamp. Teeth in the clamp and V-bolt dig into the metal of both solid and hollow shafts maintaining a perfect connection. The specially designed clamp will not crush hollow shafts. The bottom end of the actuator is held by an anti-rotation strap or by a stud provided by the damper manufacturer. The actuator is mounted in its fail-safe position with the damper blade(s) closed. Upon applying power, the actuator drives the damper to the open position. The internal spring is tensioned at the same time. If the power supply is interrupted, the spring moves the damper back to its fail-safe position. SAFETY NOTES The actuator contains no components which the user can replace or repair. 4 VAC Connect via safety isolating transformer, Class supply. /" Threaded Connector Screw a conduit fi tting into the actuator s metal bushing. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. 3/8" Flex Connector (-FC models) Mount the fl exible conduit into the actuator s metal bushing by means of the provided screw with a torque of. Nm. Jacket the actuator s input wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]).37" [60] FSLF4(-S)(-FC) US, FSLF30(-S) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time 0. [5] 0.45" [] 7.03" [79] 6.8" [73] 5.4" [38]." [8] max 0.79" [0] min 0.5" [.7] 0.75" [9].4" [57] 0.4" [6] 3.86" " [98] *Individual Fusing or Breakers are not required by Belimo. The FSLF4 draws higher peak current when driving against any type of stop. Given the technology of fuses & breakers, this requires the value of fuse or breaker to be increased to avoid nuisance opening or tripping. A amp slow blow should be used for 4VAC. A 0.5 amp slow blow should be used for 30VAC. FSLF0Dims USA CANADA LATIN AMERICA/CARIBBEAN

16 FSLF4(-S)(-FC) US, FSLF30(-S) US On/Off, Spring Return, 350 F for Half Hour, 5 Seconds Cycle Time Typical Applications The typical fi re and smoke damper requires from 5-5 in-lb of torque per square foot at 50 F F under dynamic load (000 fpm velocity). The FSLF is a single section damper actuator. For the multi section dampers, use the FSNF series. This is a direct coupled actuator. If linkages are needed use the FSNF series. Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Single section for one FSLF actuator Two section for two FSLF actuators Typical Specification Smoke Control and Combination Fire and Smoke Control Damper Actuators All smoke and combination fi re and smoke dampers shall be provided with Belimo FSLF, FSNF, or FSAF actuators. No substitutions allowed. Damper and actuator shall have UL555S Listing for 50 F (350 F) and shall comply with UBC if required by local codes. Where proof of closure switches are required, blade switches, actuator auxiliary switches, or proximity switches are allowed. Replacement Applications The number one "equal or better" requirement for use as a replacement for obsolete defective motors is the UL555S listing of the Belimo actuator with the damper for the application. The local authority having jurisdiction sets the requirements. In some cases a permit and inspection may be required. Go to for a Cross Reference from old damper actuators to Belimo. Extensive retrofi t installation instructions are available, along with technical training information. CAUTION Caution must be used when replacing failed motors with new Belimo actuators. Many old motors did not have internal springs and depended on external springs on the side of the damper or wrapped around the damper shaft to close the damper. Old motor springs must be removed or disabled. Do not remove fusible link springs if they had only fi re and no smoke functions In some cases, a BAE 65 or equal thermal sensor must be installed. 3 No ground on 4 V models 4 S4 makes to S6 when the actuator is powered open. For end position indication, interlock control, fan startup, etc., 5 FSLF4-S US and FSLF30-S US incorporate two built-in auxiliary switches. 6 Double insulated WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 4V C=Blk H=Red 30V N=Blu L=Brn Parallel Actuator Wiring 4V C=Blk H=Red 30V N=Blu L=Brn No ground on 4 V models Violet Violet Gray Gray Gnd S S S4 S6 3 4 Common, Neutral Hot 3 Ground FSLF4 US FSLF30 US NC NO Gnd FSLF4-S US FSLF30-S US FSLF30on-off_wiring FSLF30_Parallel_Aux_wiring FSLF30_Parallel_Aux_wiring Subject to change. Belimo Aircontrols (USA), Inc. Auxiliary switch wiring for FSLF4-S US, FSLF30-S US USA CANADA LATIN AMERICA/CARIBBEAN

17 FSTF0(-S) US On/Off, Spring Return, 0 VAC Torque min. 8 in-lb, for control of fire and smoke dampers Application The type FSTF spring-return actuator is intended for the operation of smoke and combination fire and smoke dampers in ventilation and air-conditioning systems. The actuator will meet requirements of UL555 and UL555S when tested as an assembly with the damper Square footage of damper operated will depend on make and model and the temperature required. Operation Mounting of the actuator to the damper axle shaft or jackshaft is via a cold-weld clamp. Teeth in the clamp and V-bolt dig into the metal of both solid and hollow shafts maintaining a perfect connection. The specially designed clamp will not crush hollow shafts. The bottom end of the actuator is held by an anti-rotation strap or by a stud provided by the damper manufacturer. The actuator is mounted in its fail safe position with the damper blade(s) typically closed. Upon applying power, the actuator drives the damper to the open position. The internal spring is tensioned at the same time. If the power supply is interrupted, the spring moves the damper back to its fail-safe position. M / - Subject to change. Belimo Aircontrols (USA), Inc. Technical Data FSTF0(-S) US Power supply nominal 0 VAC, 60 Hz tolerance 08 to 3 VAC, 60 Hz Power consumption running W, 3.5 VA holding.5 W,.5 VA max. inrush current.a Transformer sizing 5 VA (class power source) Electrical connection (-S models have cables) 3 ft, 8 GA appliance cable / conduit connector Overload protection electronic throughout 0 to 95 rotation Electrical protection actuators are double insulated Angle of rotation max 95, adjust. with mechanical stop Torque min. 8 in-lb [ Nm] Direction of rotation reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 spring return position) Running time motor < 75 sec (0 to 8 in-lb) spring < 5 F to F [0 C to 50 C] Humidity 5 to 95% RH non-condensing Ambient temperature 3 F to F [0 C to 50 C] Operating temperature Up to 50 F for / hour per UL555S test Housing NEMA type / IP4, UL enclosure type Housing material UL94-5VA. UL043 Listed for plenum use Agency listings culus acc. to UL60730-A/--4, CAN/CSA E60730-:0, CE acc. to 004/08/EC (and 006/95/EC for -S versions). UL043 smoke rated Noise level (max) running < 50 db (A) spring return 6 db (A) holding inaudible Servicing maintenance free Quality standard ISO 900 Weight FSTF0 US.6 lbs (0.57 kg) FSTF0-S US.5 lbs (0.68 kg) Rated Impulse Voltage 4kV, Type of action.aa (.AA.B for -S version), Control Pollution Degree 3. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: /4" to /" /4" to 5/6" 3.30" [83.7] 0.68" [6.7].40" [6] 3.0" [76.] 0.77" [9.5] 4.5" [4] 6.8" [59.5] 0.43" [] 0." [5.] D096 FSTF0-S US Auxiliary switch x SPST 3A 0 VAC, UL approved One fi xed at 0º and one fi xed at 80º USA CANADA LATIN AMERICA

Installation Instructions

Installation Instructions 0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

DUCT SMOKE DETECTOR D4120

DUCT SMOKE DETECTOR D4120 Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

Series 71, 72, and 76 Modutrol IV Motors

Series 71, 72, and 76 Modutrol IV Motors Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators S, S Series Low-Torque Spring- Return Direct-Coupled Actuators S, S, S, S, S, S INSTALLATION AND OPERATING INSTRUCTIONS S, S Series Low-Torque Spring-Return Direct-Coupled Actuators (DCA) are used for

More information

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V 4 613 OpenAir TM Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V GCA12...1 GCA32...1 Electromotive rotary actuators for two-position control, nominal

More information

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 1/99 Modutrol Motors Selection Guide This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 2-POSITION SPRING

More information

Use the UL555S tested area results given in damper OEM sections below.

Use the UL555S tested area results given in damper OEM sections below. Fire & Smoke Actuator Replacement Cross Reference ACTUATOR REPLACEMENT STARTS WITH THE DAMPER, NOT THE ACTUATOR. Most modern actuators can be replaced like-for-like since they function identically. These

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95 Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

How To Drive A Compact Serie 1

How To Drive A Compact Serie 1 Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

HQ Series ¼ Turn Actuator

HQ Series ¼ Turn Actuator HQ Series ¼ Turn Actuator HQ-015 thru HQ-300 Installation & Maintenance Manual HQ Series I&M Manual HQ-400-1005 1 Table of Contents: General 1.0 Actuator Mounting 2.0 External Construction 3.0 Wiring Diagrams

More information

Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Guide for PD4000 Series Power Control Center Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Operating Instructions

Operating Instructions CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

SPEED CONTROL SYSTEM

SPEED CONTROL SYSTEM SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

Series 90 Modutrol IV Motors

Series 90 Modutrol IV Motors Series 90 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 90 Modutrol IV Motors are spring return and non-spring return modulating proportional control motors. Use these motors with controllers

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

Quick running actuator

Quick running actuator ACTATOR FOR DAMPERS Quick running actuator Actuator with rotation drive. 4 Nm 8 Nm For the application with Laboratory ventilation techniques Room ventilation techniques VAV Valves Page: Content: 3 4-5

More information

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown NEX-3004 AUGUST 4, 2015 Fireye NEXUS FX04 and FX04-1 Servo Motor Installation FX04-1 Shown DESCRIPTION This bulletin describes the installation and operating instructions for the FX04 and FX04-1, 3 lb.-ft./

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

Installation and Operation Guide for PD4100 Series Power Control Centers

Installation and Operation Guide for PD4100 Series Power Control Centers Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Self Monitoring Power Supply (BPSM)

Self Monitoring Power Supply (BPSM) LIFETIME REPLACEMENT WARRANTY Self Monitoring Power Supply (BPSM) Application - When interfacing with a fire alarm system where the system s auxiliary relay cannot handle the full current potential of

More information

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd. DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

GPD 506/P5 Start-up Procedure and Checklist

GPD 506/P5 Start-up Procedure and Checklist GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008 CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand

More information

DLP-PU/E Instruction Manual

DLP-PU/E Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information