Solvents and Formulations for Liquid Chromatography
|
|
- Dominick Hardy
- 7 years ago
- Views:
Transcription
1 Solvents and Formulations for Liquid Chromatography Because You need Quality! Solvents and Formulations for Liquid Chromatography LEENDERWEG 78, 5555 CE VALKENSWAARD, THE NETHERLANDS Tel: , Fax: Website:
2 HPLC Grade LC/MS Grade ULC/MS Grade
3 For over three decades, Bio-Lab Ltd, an ISO 9001 and ISO company, has been Thanks to constant effort in R&D, we were able to put on the market over the years exceptionally high quality products resulting HPLC Grade In high performance liquid chromatography the producing high purity solvents, reagents in guaranteed and often unique specifications. intrinsic quality of the solvents is of the greatest and formulations which are distributed It also has been our task to adapt the significance. We have been optimizing our through its subsidiary, Biosolve in Benelux, specifications of selected solvents and HPLC grades to match many LC applications, France and Germany. formulations to the customer's particular use. enabling you to determine which is the best Quality assurance means the world to us. We can offer you a full range of solvents, grade for your specific need. Our QA policy is expressed from the initial reagents and formulations that are considered Gradient grade HPLC solvents are specified acceptance of the selected raw material the best available products on the LC and with the gradient elution tests for the highest through the in process control to the LC/MS market. peak and drift at critical wavelengths in order professionally analyzed finished products. to demonstrate the peak-free baseline. This All steps of production are perfectly enables you to make a better evaluation of documented and traceable, and final minor impurities assuring optimum sensitivity. distillations are performed in all-glass equipment ensuring high quality chemicals Biosolve HPLC solvents are lot-to-lot analyzed with lot-to-lot reproducibility. Certificates to meet the high quality specifications for HPLC of analysis and compliance (COA and COC) are available on request, even for long past delivered products. Continuous training of our personnel, and upgrading manufacturing and laboratory operative procedures will continue to lead us towards both our goals: highest quality and environmental Thanks to constant effort in R&D, we were able to put on the market over the years exceptionally high quality products resulting in guaranteed and often unique specifications. separations. We control the low levels of peak impurities, residue, water, acidity and alkalinity, the high chemical purity and the UV transmittance, all of which are critical parameters for a successful HPLC application. All our HPLC solvents are filtered through 0.2 µm membranes, insuring particle-free mobile phases, and are bottled under inert gas We control the low levels of peak impurities, residue, water, acidity and alkalinity, the high chemical purity and the UV transmittance, all of which are critical parameters for a successful HPLC application. care. for improved shelf life. HPLC Grade
4 HPLC Solvents, Reagents and Formulations HPLC Solvents, Reagents and Formulations UV Transmit-tance Acidity (as AcOH or HCl) UV Transmit-tance Acidity (as AcOH or HCl)
5 HPLC Solvents, Reagents and Formulations HPLC Solvents, Reagents and Formulations UV Transmit- -tance Acidity (as AcOH or HCl) UV Transmit- -tance Acidity (as AcOH or HCl)
6 LC/MS Grade Mass spectrometers work by ionizing To avoid such misleading phenomena, it is LC/MS Solvents & formulations / Purity H. Peak at UV Transmittance Ionic Metals max. ppm molecules, and then sorting and identifying the important to use solvents containing minimum ions according to their mass-to-charge (m/z) concentrations of such metal ions. Moreover, ratios. Common atmospheric pressure impurities arising from the solvents may mask ionization techniques are: low levels of target ion molecules, which will Electrospray ionization (ESI) result in faulty interpretation of the Atmospheric pressure chemical ionization chromatograms. (APCI) Biosolve LC/MS solvents are manufactured Atmospheric pressure photoionization (APPI) specifically to meet the needs of modern These instruments have two key components: LC/MS instruments, checked and guaranteed the ion source, which generates the ions, and to contain low levels of contaminants and ionic the mass analyzer, which sorts the ions. Much background. Specific UV tests and gradient of the advancement in LC/MS over the last elution control are also guaranteed to ensure decade has been in the development of ion reproducibility. sources and techniques that ionize the analyte All LC/MS solvents are filtered through 0.2 molecules and separate the resulting ions from µm, insuring particle-free mobile phases and the mobile phase. are bottled under inert gas for improved shelf When ionization occurs in the presence of life. Alkali metal, some components are susceptible to form adducts or clusters that may mask the true molecular MH+ ions. Biosolve LC/MS solvents are manufactured specifically to meet the needs of modern LC/MS instruments, checked and guaranteed to contain low levels of contaminants and ionic background. Specific UV tests and gradient elution control are also guaranteed to ensure reproducibility. LC/MS Grade
7 ULC/MS Grade ULC/MS Solvents Recent improvements on the High and For routine work, we also offer ready-made Ultra PLC instruments, coupled with sensitive ULC/MS formulations, such as: Trifluoracetic MS, PDA, ELSD, CAD, etc. detectors, have acid, Formic acid, Acetic acid and Ammonium led to special high-performing systems. Ultra acetate in Water, Acetonitrile and Methanol low detection limits and valid analysis of mixtures. These additives are used to improve molecular structures of proteins, peptides, chromatographic peak shape and to optimize oligonucleotides and other chemicals brought ionization in the MS interface. these new techniques a growing popularity, Ultra pure salts and acids are also available especially in the pharmaceutical and for mobile phase preparation. We are ready biotechnology industry. to offer our help in tailor-made formulations to Some minor impurities arising from the solvents conform to your specific needs. Fluores- UV Transmit- Ionic Metals cence Drift at H. Peak at tance max. ppb nm/max. ppb may interfere with low levels of sample impurities, or give false peaks, which will result Biosolve ULC/MS solvents and formulations in inadequate interpretation of the are micro filtered at 0.1 µm, and have a very chromatograms. low residue on evaporation, offering the best Biosolve Ultra Liquid Chromatography / Mass protection for your columns and detectors. All Spectrometry solvents (ULC/MS) for high ULC/MS reagents are packed under inert gas resolution and sensitivity were developed in for improved shelf life. close cooperation with advanced instrument companies to meet these new requirements. Biosolve ULC/MS solvents are checked and guaranteed to meet the demand for: High chemical purity, high UV transmission, lowest peak impurities and drift in the gradient elution tests to ensure reproducibility, low fluorescence impurities and low level of ionic background of less than 100 ppb of Alkali metal. ULC/MS Formulations High chemical purity, high UV transmission, lowest peak impurities and drift in the gradient elution tests to ensure reproducibility. Low fluorescence impurities and low level of ionic background of less than 100 ppb of Alkali metal. ULC/MS Grade Purity Fluores- Water UV Transmit- Ionic Metals cence Drift at H. Peak at (KF) tance max. ppb nm/max. ppb
8 ULC/MS Acids & Salts Fluorescence nm/max. ppb Drift at Water H. Peak at (KF) HPLC Gradient elution 3D chromatogram from 210nm to 400nm. Acetonitrile ULC/MS batch # and Water ULC/MS batch # System parameters: Column RP-18 spherical 5µm, 254x4.6mm, PDA 2998 detector. Gradient elution test parameters: Loading of 100% ACN for 5 min. Back program to 5% ACN in 2 min. Column equilibrium for 3 min. Gradient elution from 5% to 100% ACN in 20 min. Hold at 100% ACN for 10 min UV Transmittance Ionic Metals max. ppm Water ULC/MS Biosolve early recognized the importance of Methanol) or inherent to the analyzed sample. Water for sophisticated LC and LC-MS Over the years, the Water quality at Biosolve applications. has been constantly upgraded and at present, Minor impurities present in the water often our Water ULC/MS is produced by not less "charge" the LC columns at the early stage of than 11 monitored purification steps, including the gradient chromatographic run. short UV treatment and final filtration through Such impurities may then be released as single 0.1 µm membranes. or multiple peaks with rising gradient conditions. Our bottles are selected and treated to The operator may then consider the presence minimize ion release from the internal glass of such peak(s) as impurity(ies) that are present surface. The filling is performed under aseptic in the mobile phase co-solvent (e.g. Acetonitrile, conditions. PDA max plot gradient chromatogram from 210nm to 400nm. Acetonitrile ULC/MS batch # and Water ULC/MS batch # *For complete information on product specifications and standard packaging, please refer to our internet website at:
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
More informationUHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
More informationLC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
More informationElectrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationAnalysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column Sachiki Shimizu, FUJIFILM Fine Chemicals Co., Ltd., Kanagawa, Japan Kenneth J. Fountain, Kevin Jenkins, and Yoko Tsuda,
More informationLUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)
October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for
More informationHow To Use An Acquity Qda Detector
Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector
More informationAppendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
More informationWaters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
More informationLC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
More informationAnalysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
More informationAnalysis of Vegetable Oils by High Performance Liquid Chromatography
Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia
More information# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
More informationHigh-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
More informationOverview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationAspects of industrial purification of peptides using large-scale chromatography. Lars Andersson and Jonas Persson
Aspects of industrial purification of peptides using large-scale chromatography Introduction By Lars Andersson and Jonas Persson PolyPeptide Laboratories (Sweden) AB PO Box 30089 SE-200 61 LIMHAMN SWEDEN
More informationPerformance and advantages of qnmr measurements
Return to Web Version This is the first of a series of articles related to the launch of new organic CRMs certified by quantitative NMR under double accreditation. In this issue, we focus on CRMs intended
More informationCONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
More informationIn-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
More informationIntroduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17
Introduction to HPLC Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke Introduction to HPLC p.1/17 Sources R. Kellner, J.-M. Mermet, M. Otto, H. M. Widmer (Eds.), Analytical Chemistry,
More informationFast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
More informationNANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT
NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT AND ANALYSIS SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published
More informationUltra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
More informationDaniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz
Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische
More informationExtraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
More informationSIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
CHAPTER 5 SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 5 Simultaneous determination of Telmisartan
More informationDetermination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC
Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC Abstract: High performance liquid chromatography (HPLC) was used to determine the identity and concentrations of food dyes
More informationA feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011
A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection LGC/R/2011/181 LGC Limited 2011 GC11/0005A A feasibility study of the determination of B-group
More informationHPLC Basics, Equipment, and Troubleshooting
HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,
More informationDevelopment of a Systematic Toxicological Screening Method using an automated online-spe-lc-qqtof System (XLC-QqTOF)
Toxichem Krimtech 2011;78(Special Issue):224 Development of a Systematic Toxicological Screening Method using an automated online-spe-lc-qqtof System (XLC-QqTOF) Christoph Köhler 1, Thomas Grobosch 1,
More informationUsing Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
More informationChemical analysis service, Turner s Green Technology Group
Chemical analysis service, Turner s Green Technology Group Hourly costs, Academic collaborations leading to co-publications: 627 SEK/hr (excl. VAT) Hourly costs, Industry/Academic collaborations, no publications:
More informationNUVISAN Pharma Services
NUVISAN Pharma Services CESI MS Now available! 1st CRO in Europe! At the highest levels of quality. LABORATORY SERVICES Equipment update STATE OF THE ART AT NUVISAN CESI MS Now available! 1st CRO in Europe!
More informationMethod Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions
Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions authors Angela (Qi) Shen, Ling Morgan, Marcele L. Barroso, and Xin Zhang; Tandem Labs Tuyen Nguyen; Sepracor Inc.
More informationAnalysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection
Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection Evelyn Goh, Antonietta Gledhill Waters Pacific, Singapore, Waters Corporation, Manchester, UK A P P L I C AT
More informationSUCRALOSE. White to off-white, practically odourless crystalline powder
SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA
More informationThe Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
More informationSimultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2
Technical ote Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Alek. Dooley, Carmai Seto, esham Ghobarah, and Elliott B. Jones verview:
More informationAutomated Method Development Utilizing Software-Based Optimization and Direct Instrument Control
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,
More informationfor mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry
Thermo Scientific Pierce Controls and Standards for Mass Spectrometry calibration tools for mass spectrometry Ensure confidence in instrument performance with Thermo Scientific Pierce Calibration Solutions
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationHigh Sensitivity MS Determination of Carryover in a New Autosampler Design
High Sensitivity MS Determination of Carryover in a New Autosampler Design 1 William Hedgepeth*, Sue Steinike Shimadzu Scientific Instruments, Columbia, MD USA Mauro Aiello, Robert Ellis, Andre Schreiber,
More informationHS 1003 Part 2 HS 1003 Heavy Metals Test
HS 1003 Heavy Metals Test 1. Purpose This test method is used to analyse the heavy metal content in an aliquot portion of stabilised hot acetic acid extract by Atomic Absorption Spectroscopy (AAS). Note:
More informationThermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
More informationHenry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS
Development of Integrated Informatics Workflows for the Automated Assessment of Comparability for Antibody Drug Conjugates (ADCs) Using LC-UV and LC-UV/MS Henry Shion, Robert Birdsall, Steve Cubbedge,
More informationMonoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry
Monoclonal ntibody Fragment Separation and haracterization Using Size Exclusion hromatography oupled with Mass Spectrometry uthors Haiying hen Katherine McLaughlin Sepax Technologies, Inc. 5 Innovation
More informationSelective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS
Application Note: 446 Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Jonathan McNally and Michael Belford, Thermo Fisher Scientific, San Jose, CA James Kapron, Thermo Fisher Scientific,
More informationOasis HLB Cartridges and 96-Well Plates
CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION
More informationUnique Bonding Chemistry
columns Acclaim HPLC Columns Reversed-phase silica columns for pharmaceutical, nutraceutical, environmental, food, and life science applications in HPLC. High hydrophobicity, low polarity phases LC/MS
More informationSTANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA 94305-5080
Training on the ZQ Open access MS Questions? Contact Dr. Allis Chien allis@stanford.edu 650-723-0710 0710 STANFORD UNIVERSITY MASS SPECTROMETRY STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD
More informationOverview. Purpose. Methods. Results
A ovel Approach to Quantify Unbound Cisplatin, Carboplatin, and xaliplatin in Human Plasma Ultrafiltrate by Measuring Platinum-DDTC Complex Using LC/M/M Min Meng, Ryan Kuntz, Al Fontanet, and Patrick K.
More informationVALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY
More informationof Biologics Using LC/MS in Compliant Laboratories
Demonstrating Comparability and Consistency of Biologics Using LC/MS in Compliant Laboratories Patrick Boyce Biopharmaceutical Marketing Manager Europe & India Waters 2011 Waters Corporation Overview Challenges
More informationAnalytical Test Report
Analytical Test Report Customer: Address (City, State): Purchase Order: Report Number: Project Number: Date Received: Date of Report: Test Location: Boulder, CO. Assay: Part Number: Amino Acids by HPLC
More informationPrepTip. Reverse Phase PrepTip User Guide
PrepTip Reverse Phase PrepTip User Guide All text, photographs and illustrations are copyrighted by Harvard Apparatus, Inc. 2004. PrepTip is a trademark of Harvard Apparatus, Inc. Harvard Apparatus 84
More informationThermo Scientific Syncronis HPLC Columns. Technical Manual
Thermo Scientific Syncronis HPLC Columns Technical Manual Thermo Scientific Syncronis HPLC Columns When developing a new method, one of the most important goals for the chromatographer is to achieve a
More informationSeparation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study
Application Update Now sold under the Thermo Scientific brand Separation of Peptides from Enzymatic Digestion on Different claim Columns: A Comparative Study INTRODUCTION Separation of peptides which can
More informationGENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,
More informationHow To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
More informationPipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE
User Guide for Reversed-Phase Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE Notice The information in this document is subject to change without notice and should not be construed as a commitment
More informationHigh Resolution LC-MS Data Output and Analysis
High Resolution LC-MS Data Output and Analysis Your Sample LC/MS Result Sample Sample Efficient Separation Preparation Introduction Gradient (column) Today Data (computer) LC- MS Ions Detection Ions Separation
More informationFeatures Rich Detectors for Every Laboratory and Application
SofTA ELSD Features Rich Detectors for Every Laboratory and Application Model 2300 New modern design. Similar performance to Model 1300 Model 1300 Designed for UPLC with narrow peak widths and high sensitivity.
More informationThe basic division explosives for forensic purposes is shown in Fig. 1
Isolation, concentration and determination of post blast residua by liquid chromatography with DAD detector capillary electrophoresis with DAD detector Firearm fumes (gunshot residua, GSR) - various metallic
More informationDetermination of Calcium and Magnesium in Brine
Application Note Determination of Calcium and Magnesium in Brine INTRODUCTION To prevent membrane poisoning, new membrane technology in chlor-alkali cells requires feed brine that is relatively free of
More information[ Care and Use Manual ]
PREP Calibration Mix DIOS Low i. Introduction Pre-packaged PREP Calibration Mixtures eliminate the need to purchase and store large quantities of the component calibration reagents, simplifying sample
More informationIntergovernmental Group- on Tea 10 th Session New Dehli, 12-14 May 2010
ISO Standards for Tea Intergovernmental Group- on Tea 10 th Session New Dehli, 12-14 May 2010 Andrew Scott, Chairman ISO TC/34 SC 8 Tea 1 2 Tea Over 3 million tonnes produced In over 30 countries Providing
More informationAutomation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
More informationDissolved and precipitated oxalate
Accepted 2005 Process liquors from bleach plants Dissolved and precipitated oxalate Using Ion Chromatography 0 Introduction In bleach plants of pulp mills with a high degree of system closure, there is
More informationContents. List of Contributors XIII The structure of The HPLC-Expert" Preface XVII
V List of Contributors XIII The structure of The HPLC-Expert" Preface XVII XV 1 LC/MS Coupling 1 1.1 State of the Art in LC/MS 1 Oliver Schmitz 1.1.1 Introduction 1 1.1.2 Ionization Methods at Atmospheric
More informationProject 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids
Willamette University Chemistry Department 2013 Project 5: HPLC Analysis of Capsaicinoids LABORATORY REPORT: Formal Writing Exercises PRE-LAB ASSIGNMENT Read the entire laboratory project and section 28C
More informationCapillary HPLC Introduction
Capillary HPLC Introduction Capillary HPLC Liquid chromatography/mass spectrometry, LC/MS, is a revolutionary tool in the chemical and life sciences. LC/MS is accelerating chemical research by providing
More informationGuidance for Industry
Guidance for Industry Q2B Validation of Analytical Procedures: Methodology November 1996 ICH Guidance for Industry Q2B Validation of Analytical Procedures: Methodology Additional copies are available from:
More informationSPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
More informationRapid Separation and Detection of Amino Acids by HPLC-HPIMS TM
Rapid Separation and Detection of Amino Acids by HPLC-HPIMS TM In addition to being the structural units that make up proteins, amino acids play important roles in gene expression, cell signaling, and
More informationMethod development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report
of melamine-ware by GC-MS and LC-MS/MS Page 1 of 15 Method development for analysis of formaldehyde in foodsimulant extracts of melamine-ware by GC-MS and LC-MS/MS December 2012 Contact Point: Chris Hopley
More informationProtein Separation Technology
[ ] Protein Separation Technology Protein Separation Technology The analysis and characterization of protein samples requires the detection of small chemical differences between large molecules. Most often
More informationFast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation
Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.
More informationApplication Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary
Application Note Increasing the activity of monoclonal antibody isoforms by MCSGP Category Matrix Method Keywords Countercurrent chromatography, FPLC Antibodies MCSGP FPLC, Biobetters, MCSGP, countercurrent
More informationamazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS
amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is
More informationMicromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
More informationApplication Note. Separation of three monoclonal antibody variants using MCSGP. Summary
Application Note Separation of three monoclonal antibody variants using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, Biochromatography; FPLC Protein A-purified monoclonal
More informationTherapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS
Therapeutic Drug Monitoring of Antiretroviral Drugs with PLC-M Ursula Gutteck-Amsler, Katharina M. Rentsch Abstract Prospective and retrospective studies have provided some evidence of the clinical and
More informationUtilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform
Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform Charles Yang, Leo Wang, Dipankar Ghosh, Jonathan Beck,
More informationAdvantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites
Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Carmen T. Santasania and David S. Bell SUPELCO, 595 North Harrison Road, Bellefonte, PA 16823 T404045 GUS Abstract
More informationMetabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants
Metabolomic Profiling of Accurate Mass LC- Data to Identify Unexpected Environmental Pollutants André Schreiber 1, David Cox 1, Nadia Pace 1, Christopher Borton 2 1 AB SCIEX, Concord, ntario, Canada; 2
More informationGas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationDRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)
September 2010 RESTRICTED DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010) DRAFT FOR COMMENTS This document was provided by a quality control expert and
More informationBasics of LC/MS. A Primer
Basics of LC/MS A Primer Contents Introduction..................................... 2 Instrumentation.................................. 4 Interfacing LC and MS................................. 4 Atmospheric
More informationThe Theory of HPLC. Gradient HPLC
The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims
More informationMaterials for Pharmaceutical Manufacturing
Materials for Pharmaceutical Manufacturing GRACE WHITEPAPER Vydac 150HC Purification Media Greater Loading Capacity and Resolution for Improved Productivity in Peptide Purification Technical Development:
More informationSeparation of Amino Acids by Paper Chromatography
Separation of Amino Acids by Paper Chromatography Chromatography is a common technique for separating chemical substances. The prefix chroma, which suggests color, comes from the fact that some of the
More informationApplication Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary
Application Note Purifying common light-chain bispecific antibodies using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, biochromatography Antibodies MCSGP Bispecific antibody,
More informationHPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
More informationA Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC
A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC HPLC Columns David Carr Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated
More information