ELSO MEDIOPT care 2009

Size: px
Start display at page:

Download "ELSO MEDIOPT care 2009"

Transcription

1 ELSO MEDIOPT care 2009

2 ELSO MEDIOPT care 2

3 What are call systems? A call system is a visual/acoustic system that can be used: To call personnel to the place where the call was triggered from To search for personnel or groups of people To forward information (e.g. from medical devices) 3

4 Patient call system for hospitals and nursing facilities DIN 0834 areas of application: Old people's homes Assisted living Medical practices Dialysis stations Hospitals Adult day-care centres 4

5 Standards and regulations for call systems Electrical engineering standards are created by the DKE (German Electrical Engineering Commission) -> Subsidiary of the VDE and the German Standards Committee Call systems -> DKE subcommittee "General signalling systems and signalling devices" is responsible Responsible for the DIN VDE 0834 standard "Light call systems; installing and operating systems in hospitals, nursing homes and penal institutions" 5

6 Excepted from the DIN VDE 0834 standard Emergency call systems used for ensuring the safety of persons living at home Systems for domestic use (home emergency call systems) are subject to the EN standard 6

7 Key features of the DIN VDE 0834 standard Every bed has a call button -> easily reachable Call button clearly marked and visible in the dark Visual display of triggered call -> reassurance light Presence buttons with acoustic signallers (call forwarding) must be installed in rooms where nursing staff are usually to be found Triggering of emergency calls when present with appropriate signalling A room signal light (RSL) must be installed outside every room with a red + green display and an optional white display (WC call) 7

8 Key features of the DIN VDE 0834 standard The light must be clearly visible at 500 lux A call must be displayed on the RSL within 1 second Text displays must be recognisable from 20 m at 500 lux Nursing staff must receive information within 5 s The presence button is used for cancelling the call Non-visible rooms (wet rooms) require a separate cancel button No common covers for call / operating devices and high voltage devices 8

9 Key features of the DIN VDE 0834 standard For call systems with intercoms, calls may be remotely cancelled when voice communication has occurred Non-intercom systems -> no remote cancel - but the acoustic call forwarding may be cancelled. System voltage less than 30 V AC or 60 V DC System voltage may only be used for the intended purpose Exception: An impulse relay switch for a reading lamp or similar. This must be permanently connected and have its own overvoltage protection. Transmission paths for other systems may not be used for call systems (separate cable) 9

10 Key features of the DIN VDE 0834 standard Call systems require emergency power no later than 15 s after the normal power has failed. Must be maintained for 1 h / calls must be stored for at least 30 s after a power failure. System voltage less than 30 V AC or 60 V DC Cables connecting buildings must be equipped with overvoltage protection at the exit points All protective grounds connected to the call system must be connected to the same main potential equalisation point. If this is not possible then the individual areas must be galvanically isolated. 10

11 Installation heights Operating device (call button): m Operating elements for wheelchairs: 0.85 m (as per DIN Barrier-free construction) Pull button: must be at least 20 cm above the highest spray head position Pull cord must be reachable by a person lying on the floor Operating devices with text display: 1.5 m 1.8 m not subjected to direct sunlight Lights / Hall displays: 1.3 m 2.2 m 11

12 Maintenance / Repair An operating log must always be available at the system All faults must be documented, with date/time, cause, author and repair measures Repairs must begin within 24 h of a fault occurring and this must also be documented in the operating log Unless otherwise defined by the manufacturer, maintenance must be performed quarterly and documented in the operating log 12

13 System characteristics Conceived for large and small applications Max. 59 stations, each with 99 rooms = 5841 rooms Consists of different independent microprocessor controlled devices, connected via a bus system Every module has a microcomputer The modules operate autonomously, which allows easy expansion of the system Data traffic is coded with addresses Permanent independent self-monitoring of the microcomputers, which allows faults and/or dropouts to be individually recognised and signalled Programming without special software, simple cabling In the case of power cuts, the last information state of the modules is retained With and without room intercoms 13

14 Product range Input devices Display devices Additional devices Call cancel button Cancel button /WC Pull button Pear button / light button Call button with socket Socket Pneumatic button Designer lights Single sided corridor display Double sided corridor display Duty room display Room display Room intercom Power supply / UPS Station transfer point Wireless transmitter / receiver PC with SW for logging Call-forwarding to DECT Telephone dialler SMS controller Connection to monitoring device 14

15 Bus types Room bus: Connects all devices in a room (incl. bathroom) e.g.: Call cancel button, WC cancel button, pull button pear button / light switch, call button with socket socket, pneumatic button Station bus: Connects all room modules Floor bus: Connects all station transfer points 15

16 Installation 1st floor Basic structure Station transfer point Floor bus Station bus Room bus Ground floor Station transfer point Station bus Room bus 16

17 Room bus description WC Station Station bus bus Room bus Shield 24 V DC Room data bus All light call system devices in a room are connected to the room bus. The room bus has 4 conductors. "d" = data "t" = clock "+24" = + 24VDC "GND"= ground These 4 conductors are to be connected to the terminals of the same designation on the room module (different versions possible) in exactly the manner shown here. This connection can be a room bus, implemented in a star configuration or mixed. The cable length (sum of all cables) must not exceed 100m. A cable of type: JY (St) Y 2x2x0.8 must be used for the room bus. The shield is to be connected to the GND terminal of each room module. To avoid short circuits at the device, the shield must be insulated. 17

18 Station bus description RM = room module ST = station transfer point PS = power supply Further stations All the room modules for the station must be connected to the station bus. Stub cables are to be avoided. The station bus should be laid as a ring cable. ELSO GmbH recommends closing the ring. This results in double data reliability. Please make absolutely sure that the conductors ("a"; "b"; "+24VDC" and "GND") are not swapped. The station bus cable (subsequently referred to as SYK=system cable) must be of type: Lapp Kabel UNITRONIC Bus Combi EIB 2x2x x1.5, or equivalent quality. The shield must be connected to each of the GND terminals. To avoid short-circuits in the device, the shield must be insulated. The data cable must not exceed a length of 500m. 18

19 Installation A room module is required for every room. Room modules are contained in: Duty room module Room module with call cancel button (also available with a display) Room module with room indicator light 19

20 Installation Room installation using a room module with room signal light Room module with room signal light 2x2x0.8mm 2 Room bus WC All devices are connected to the room bus. The room bus has 4 conductors. "d" = data "t" = clock "+24" = + 24VDC "GND"= ground 20

21 Installation Connection example: Data Clock + 24VDC Ground Bus Power supply 21

22 Installation Room module Room module with room indicator light For quiescent current monitoring of the call cables, all external call inputs (R-Z and R-W) must be terminated with a 3.6 k termination resistor. This terminator is installed at the factory and must not be removed. Terminal X1 Station bus X2 Room bus X3 Inputs X10 Outputs Pin Function 1 +24V 2 a (data "a" station bus) 3 b (data "b" station bus) 4 GND 1 +24V 2 +24V 3 d, room bus data (terminal designation: BL-B/d) 4 t, room bus clock (terminal designation: R-B/t) 5 GND 6 GND 1 +24V 2 R-Z, room call 3 S1 not used 4 R-W, not used 5 A-W, not used 1 TG acoustic alarm, call forwarding 2 ZL-R, (red) room call 3 ZL-W, (white)wc call 4 ZL-S, (green) nurse 5 GND 22

23 Installation Room bus Room module with RSL BUS data cable Station bus All light call system devices in a room are connected to the room bus. The room bus has 4 conductors -> Terminal strip X2. "d" = data = "BL-B/d" "t" = clock = "R-B/t" "+24" = + 24VDC= "+24V" "GND" = Ground = "GND" 23

24 Installation Room installation using a room module with call cancel button (also available with a display) Room module with call cancel button 2x2x0.8mm 2 Room bus WC 24

25 Installation DOUBLE SWITCH SOCKET 25

26 Installation Room module with call cancel button and display To station bus Twisted-pair cable Room bus data Station bus data From station bus A distribution box is necessary when using an SYK system cable. This is provided with delivery (-> Terminals with connection cable and fuse - > slow blow fuse 250V / 2.5A ). The power supply cables of the SYK are connected to the +24V and GND distribution box terminals. The red output cable of the distribution box is connected to +24V, the blue to GND. The supplied system cable 2x2x0.8 must be used for connecting to the station bus. All light call system devices in a room are connected to the room bus. The room bus has 4 conductors -> Terminal strip X2. "d" = data "t" = clock "+24" = + 24VDC "GND" = Ground 26

27 Installation Room module with call cancel button and display White WC call Red Room or bed call Green Nurse present 27

28 Installation Duty room module with call cancel button and display Room module Duty room module with call cancel button and display 2x2x0.8mm 2 Room bus WC 28

29 Description Trainee nurse presence button Nurse call/ Nurse emergency call button Doctor emergency call button Function button 2 Speaker Function button 1 Microphone Nurse presence button Doctor presence button Function button 4 Display Function button 3 29

30 Representation of floor bus Foreign system Station transfer point Floor bus Station transfer point Shield Data a Data b Speak a1/b1 Speak a2/b2 30

31 Presence cancel button Address Function 0 Presence S1-1 + acoustic call forwarding 1 Presence S1-2 2 Presence S1-3 3 Presence S1-4 4 Presence S1-5 5 Presence S1-6 6 Presence S WC call cancel 1 9 WC call cancel 2 A WC call cancel 3 B WC call cancel 4 C D E F All presence markings are summarised as a collective message for forwarding, the display of the presence occurs at all buttons simultaneously in parallel. (6 times due to the bed-wise installation) The WC call cancel simultaneously affects all triggered WC calls for the room. The acoustic alarm is only activated for devices having an address of 0. 31

32 Call presence / cancel button Address Function 0 Room call 1 and presence S1-1 + acoustic call forwarding 1 Room call 2 and presence S1-2 2 Room call 3 and presence S1-3 3 Room call 4 and presence S1-4 4 Room call 5 and presence S1-5 5 Room call 6 and presence S WC call 1 with cancel 8 WC call 2 with cancel 9 WC call 3 with cancel A WC call 4 with cancel B C D E F All calls are summarised as a collective message for forwarding. The reassurance light only illuminates at the device from which the call was triggered. All presence markings are summarised as a collective message for forwarding, the display of the presence occurs at all buttons simultaneously in parallel. The WC call cancel simultaneously affects all triggered WC calls for the room. The acoustic alarm is only activated for devices having an address 32 of 0.

33 Call button Address 0 Room call 1 1 Room call 2 2 Room call 3 3 Room call 4 4 WC call 1 5 WC call 2 6 WC call 3 7 WC call A Bed call 1-3 B Bed call 2-3 C Bed call 3-3 D Bed call 4-3 E Bed call 5-3 F Bed call 6-3 Function All calls except the bed calls are summarised as a collective message for forwarding. The reassurance light only illuminates at the device from which the call was triggered. 33

34 Call button with system socket Address Function 0 1 Bed call Bed call Bed call Bed call Bed call Bed call Room call 2 8 Room call 3 9 Room call 4 A Bed call 1-2 B Bed call 2-2 C Bed call 3-2 D Bed call 4-2 E Bed call 5-2 F Bed call 6-2 A button address must never be assigned twice, i.e. the address "Room Call 2" must only exist once per room. This also applies to all other cases. Failure to do this will result in system malfunctions. However, a single bed can be assigned a maximum of 3 buttons with different sub-addresses. A call button with system socket provides two sub-addresses "-1" and "-2" (for example: "Bed call 1-1" and "Bed call 1-2"). Note: The call button also provides the sub-address "-3" (for example: "Bed call 1-3"). The pull button and pneumatic button also provide the sub-address "-1" (for example: "Bed call 1-1") 34

35 Call button with system socket Ext. Rel. 2 Ext. Rel. 1 Load 2 Load 1 Power supply: 24 VDC Current consumption: 30 ma Degree of protection: IP 20 Output loading: max. 24VDC / 0.2A / cos = 1 35

36 Room module with room indicator light Setting for jumper X4 Left "ON": (factory setting) 24 Volt supply switched on Right "OFF": 24 Volt supply for the room module and the entire room installation is switched off. This should always be switched over for servicing / de-installation purposes! Settings for jumpers X5a and X5b Down: Factory setting: Both jumpers must connect the terminals BL-B/d and R-B/t in order to implement connection of devices via the room bus. Up: Thus jumper setting must not be selected -> Malfunction! 36

37 Room module with room indicator light Extract from the address table No Off On On On On On On On 2 On Off On On On On On On 3 Off Off On On On On On On 4 On On Off On On On On On 5 Off On Off On On On On On 6 Off Off Off On On On On On 7 Off Off Off On On On On On 8 On On On Off On On On On 9 Off On On Off On On On On 10 On Off On Off On On On On 11 Off Off On Off On On On On 12 On On Off Off On On On On 13 Off On Off Off On On On On 14 On Off Off Off On On On On 15 Off Off Off Off On On On On 16 On On On On Off On On On 17 Off On On On Off On On On 18 On Off On On Off On On On 19 Off Off On On Off On On On 20 On On Off On Off On On On 21 Off On Off On Off On On On 37

38 DCF radio receiver 38

39 DCF radio receiver Signal Error Sends The radio clock is connected to the floor bus via the data cables "at" and "bt". It is essential that the conductors ("a "; "b"; "+24VDC" and "GND") are not swapped. 39

40 DCF radio receiver 1: Ground 2: + Operating voltage V- 3: DCF output 40

41 Corridor display 41

42 Corridor display Plug Text display The hall display (KDIS8 -> Hall display 8 characters) is used for displaying calls and call requests in light call systems. The display is connected to the station bus and reports the information from station transfer points and room modules. 8 characters are available on the display for showing call information. The call type is displayed using 2 characters and the call location using 6 characters. The call location is represented by the electrical station and room address. Electrical addresses are displayed in the following format: SS RR ZZ SS : Station address RR : Call type ZZ : Room address 42

43 Corridor display Displayed as (program version KDIS8-XX) Level of Language Display urgency Call type German Italian Hungarian Polish English type 1 Doctor call A M O L M Blinking Diagnostic call D D D D D Blinking WC call W W W W W Static Room emergency call Z S S P R Blinking Bed emergency call B L B M B Blinking 2 Room call Z S S P R Static Bed call B L B M B Static Telephone call T T T T T Static 3 Doctor call request Aà Mà Oà Là Mà Blinking S1 call request S1à I1à N1à S1à N1à Blinking S2 call request S2à I2à N2à S2à N2à Blinking Doctor call request, foreign station S1 call request, foreign station S2 call request, foreign station ßA ßM ßO ßL ßM Blinking ßS1 ßI1 ßN1 ßS1 ßN1 Blinking ßS2 ßI2 ßN2 ßS2 ßN2 Blinking 43

44 Room intercom Foreign system Duty room Station bus 1 Station transfer point Floor bus Station bus 2 Hall display Station transfer point Room 101 Room bus...addition al devices Shield Data a Data b Speak a1/b1 Speak a2/b2 Room

45 Many thanks for your attention 45

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation

More information

Quantec Wiring Instructions

Quantec Wiring Instructions Approved Document No. DNUQ777 Rev Quantec Wiring Instructions GENERAL Quantec can be compared to a very sophisticated analogue addressable fire alarm system where the integrity of the wiring is of paramount

More information

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges 7 7Z0 Synco Konnex bus For devices of the Synco 700 / RXB ranges KNX The Konnex bus (short KNX) unites the three existing bus technologies EIB (European Installation Bus also called Instabus), BatiBUS,

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject

More information

SYSTEM 45. C R H Electronics Design

SYSTEM 45. C R H Electronics Design SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

RS - SPM. Serial parallel translator module

RS - SPM. Serial parallel translator module ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: info@resatron.de RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

GB Gira nurse call system Plus

GB Gira nurse call system Plus GB Gira nurse call system Plus Installation, start-up Gira nurse call system Plus Quick start Gira nurse call system Plus system overview This quick start gives you a brief overview of the installation

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

GB Gira nurse call system Plus Planning, installation, start-up, operation. Gira Nurse Call System Plus System manual

GB Gira nurse call system Plus Planning, installation, start-up, operation. Gira Nurse Call System Plus System manual GB Gira nurse call system Plus Planning, installation, start-up, operation Gira Nurse Call System Plus System manual Contents Contents Contents... 3 1. Introduction... 9 1.1 General Information... 9 1.2

More information

CONCENTO PLUS System Description

CONCENTO PLUS System Description CONCENTO PLUS System Description COMMUNICATION IN PERFECTION For nursing homes and assisted living Safety in accordance with DIN VDE 0834 Part 1 and 2 This manual was compiled with great care and all the

More information

Shunt lock function 3066 Operator Instructions

Shunt lock function 3066 Operator Instructions Shunt lock function 3066 Operator Instructions Version: January 2004 Contents Deactivation unit Deactivation unit Deactivation unit Activation unit with configuration MASTER Alarm System 1.0 Shunt lock

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

Microprocessor Home Security System

Microprocessor Home Security System numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

LED - Indicator Panels

LED - Indicator Panels energy management systems 09 LED - Indicator Panels Standard LED - Indicator Panels LM...72, LM...96, LM...144 page 9/1 Indicator panels with 3 color LEDs SM...96 page 9/9 LED - INDICATOR PANELS LED-Indicator

More information

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx

3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx 3x cinch/s-video socket Order no.: 33 1532 xx USB/3.5 mm audio socket Order no.: 33 1539 xx VGA socket Order no.: 33 1540 xx VGA socket with screw-in lift terminals Order no.: 33 1541 xx High definition

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

SAILOR C4900/C4901 Installation Manual

SAILOR C4900/C4901 Installation Manual SAILOR C4900/C4901 Installation Manual Introduction SAILOR The communication products and systems of Thrane & Thrane are recognized under the brand name SAILOR. The Sailor name has become a guarantee of

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH28CS-12kV Hi Pot Tester Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01

Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01 Introduction The requirements relating to driving safety, driving comfort, exhaust emissions and fuel economy are are becoming ever more stringent. This entails more intensive information exchange between

More information

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2 1. Introduction 1 2. Software Installation 2 2.1 System Requirements 2 2.2 TroxMConnect Installation 2 2.3 Connection to the PC 3 3. TroxMConnect Description 4 3.1 Starting the Software 4 3.2 Layout 4

More information

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders General The MGL Avionics CAN bus interface for the Trig Avionics TT21 and TT22 transponders provides a simple solution to allow any

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Nurse Call Systems According to DIN VDE 0834

Nurse Call Systems According to DIN VDE 0834 Nurse Call Systems According to DIN VDE 0834 Safely into the future Safety and Security Division Planning Brochure for Nurse Call Systems According to DIN VDE 0834 Notes on Planning, Installation, Operation

More information

G3 Series PROFIBUS DP Technical Manual

G3 Series PROFIBUS DP Technical Manual G3 Series PROFIBUS DP Technical 3835063 A - Table of Contents PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined by PROFIBUS specification)...3

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

ABS Flash Code (Blink Code) Instructions

ABS Flash Code (Blink Code) Instructions ABS Flash Code (Blink Code) Instructions Innovative Products of America Incorporated Tinker Street, Woodsttock, NY 8 Local: 8-6-00 Toll Free: 888-86-8 Fax: 8-6-600 www.ipatools.com infor@ipatools.com ABS

More information

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,

More information

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

DOEPFER MIDI TO SYNC INTERFACE MSY2. User's Guide (English)

DOEPFER MIDI TO SYNC INTERFACE MSY2. User's Guide (English) DOEPFER MIDI TO SYNC INTERFACE MSY2 User's Guide (English) www.doepfer.com INTRODUCTION MSY2 is an interface that converts the MIDI realtime events CLOCK, START and STOP into the corresponding signals

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information

Siemens Communications. Siemens HiPath 1220 Simply a much better way to communicate

Siemens Communications. Siemens HiPath 1220 Simply a much better way to communicate Siemens Communications Siemens HiPath 1220 Simply a much better way to communicate System Highlights ISDN System (2 BRA/S 0 ) with flexible extension ports Mix and match of digital system phones and /

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

WITURA CORPORATION SDN BHD

WITURA CORPORATION SDN BHD WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:

More information

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad) KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

Mitel DECT Base Stations

Mitel DECT Base Stations Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base

More information

1 Technical Description Lokal-200PC

1 Technical Description Lokal-200PC 1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection

More information

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel

More information

COMPALARM AP GENERAL MAIN FEATURES

COMPALARM AP GENERAL MAIN FEATURES GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright

More information

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

KNX IP INTERFACE IN00A02IPI. Operating and installation manual KNX IP INTERFACE IN00A02IPI Operating and installation manual Product: IN00A02IPI Description: KNX IP INTERFACE Document: Version: 1.4 Date: 02/09/2014 www.eelectron.com, info@eelectron.com 1/8 Application

More information

Product Information Sheet UH36 Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150 Operation Manual Plasma torch height controller. Model: Compact THC Controller 150 Notes on safety WHEN THE DEVICE IS IN OPERATION, VOLTAGE HAZARDOUS TO HEALTH AND HUMAN LIFE IS PRESENT INSIDE THE HOUSING

More information

Air conditioning, electrical testing

Air conditioning, electrical testing just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

Installation and Operation Manual

Installation and Operation Manual GST102 GST104 Conventional Alarm Control Panel nstallation and peration Manual (ssue3.03, November 2005) nstallation and peration Manual The ntelligent Solution CNTENTS 1 General... 1 2 Technical Specifications...

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

GSM Alarm System User Manual

GSM Alarm System User Manual GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

Vibration Monitoring System Adash 3600

Vibration Monitoring System Adash 3600 " User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,

More information

Intelligent GSM Auto-dial Alarm System User s Manual

Intelligent GSM Auto-dial Alarm System User s Manual Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY SECTION F (REV.B) INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY Download from: www.urmetdomus.com Technical Manuals area BASIC SYSTEM DIAGRAMS

More information

Section B: Electricity

Section B: Electricity Section B: Electricity We use mains electricity, supplied by power stations, for all kinds of appliances in our homes, so it is very important to know how to use it safely. In this chapter you will learn

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Business/ Home GSM Alarm System

Business/ Home GSM Alarm System Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

GSM-DL2 GSM auto dialer

GSM-DL2 GSM auto dialer Introduction GSM-DL2 GSM auto dialer GSM-DL2 is a GSM auto dialer; designed for car alarm, boat alarm, home alarm and other applications. When it is triggered, it dials pre-programmed telephone numbers

More information