CODE CHANGE PROPOSAL FORM (See instructions on page 2) Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee
|
|
- Gloria Blankenship
- 3 years ago
- Views:
Transcription
1 CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Tables R Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee Revise as follows: 1. Revise Table R as follows: TABLE R WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS Footnote a. This table is based on a 130mph basic wind speeds and a 33-foot mean roof height. 2. Revise Section R as follows: R Applicability limits. The provisions of this section shall control the construction of cold-formed steel floor framing for buildings not greater than 60 feet ( mm) in length perpendicular to the joist span, not greater than 40 feet ( mm) in width parallel to the joist span, and less than or equal to three stories above grade plane. Cold-formed steel floor framing constructed in accordance with the provisions of this section shall be limited to sites subjected to a maximum where the basic design wind speed is not greater than of 110 miles per hour (49 m/s), the Exposure Category is B or C, and the a maximum ground snow load is not greater than of 70 pounds per square foot (3.35 kpa). 3. Revise Table as follows: TABLE R MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2 a. Design required. b. Table is limited to buildings located where the basic wind speed is 100mph or less and for which the seismic design category is A, B, C, D0, D1, or D2 cb. Applicability of this table assumes the following: Snow load not exceeding 25 psf, fb not less than 1310 psi determined by multiplying the AF&PA NDS tabular base design value by the repetitive use factor, and by the size factor for all species except southern pine, E not less than psi, tributary dimensions for floors and roofs not exceeding 6 feet, maximum span for floors and roof not exceeding 12 feet, eaves not over 2 feet in dimension and exterior sheathing. Where the conditions are not within these parameters, design is required. dc. Utility, standard, stud and No. 3 grade lumber of any species are not permitted.
2 4. Revise Table as follows: TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1) Footnote g. Specified alternate attachments for roof sheathing shall be permitted for basic wind speeds less than 100 mph. Fasteners attaching wood structural panel roof sheathing to gable end wall framing shall be installed using the spacing listed for panel edges. 5. Revise Table as follows: TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND a, b, c PRESSURES MINIMUM NAIL Size Penetration (inches) MINIMUM WOOD STRUCTURAL PANEL SPAN RATING MINIMUM NOMINAL PANEL THICKNESS (inches) MAXIMUM WALL STUD SPACING (inches) PANEL NAIL SPACING Edges (inches o.c.) Field (inches o.c.) MAXIMUM BASIC WIND SPEED (mph) Wind exposure category B C D 6. Revise Table R as follows: TABLE R BRACED WALL LINE SPACING APPLICATION CONDITION BUILDING TYPE Wind bracing Basic wind speed 85mph to 110 mph BRACED WALL LINE SPACING CRITERIA Exception to Maximum Spacing Maximum Spacing Detached, Townhouse 60 feet None 7. Revise Table as follows: TABLE R (1) BRACING REQUIREMENTS BASED ON WIND SPEED Footnote c. Method CS-SFB does not apply where the basic wind speed is greater than 100 mph.
3 8. Revise Table as follows: TABLE R BRACING METHODS Footnote d. Method CS-SFB does not apply in Seismic Design Categories D0, D1 and D2 and in areas where the basic wind speed exceeds 100 mph. 9. Revise Table as follows: METHOD (See Table R ) ABW SDC A, B and C basic wind speed < 110 mph SDC D o, D 1 and D 2, basic wind speed < 110 mph TABLE R MINIMUM LENGTH OF BRACED WALL PANELS MINIMUM LENGTH a (in) Wall Height 8 feet 9 feet 10 feet 11 feet 12 feet NP NP CONTRIBUTING LENGTH (in) Revise Table as follows: TABLE R MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS SEISMIC DESIGN CATEGORY AND WIND SPEED SDC A, B and C Basic w Wind speed < 110 mph SDC D o, D 1 and D 2 Basic w Wind speed < 110 mph SUPPORTING/STORY HOLD DOWN FORCE (lb) Height of Braced Wall Panel 8 ft 9 ft 10 ft 11 ft 12 ft One story First of two story One story NP a NP a First of two story NP a NP a 11. Revise Section R as follows: R Length of bracing. The length of bracing along each braced wall line shall be the greater of that required by the basic design wind speed and braced wall line spacing in accordance with Table R (1) as adjusted by the factors in the Table R (2) or the Seismic Design Category and braced wall line length in accordance with Table R Angled walls shall be permitted to be counted in accordance with Section R , and braced wall panel location shall be in accordance
4 with Section R The seismic adjustment factors in Table R (4) shall not be applied to the length of bracing determined using Table R In no case shall the minimum total length of bracing in a braced wall line, after all adjustments have been taken, be less than 48 inches (1219 mm) total. 12. Revise Section R as follows: R Connections to roof framing. Top plates of exterior braced wall panels shall be attached to rafters or roof trusses above in accordance with Table R602.3(1) and this section. Where required by this section, blocking between rafters or roof trusses shall be attached to top plates of braced wall panels and to rafters and roof trusses in accordance with Table R602.3(1). A continuous band, rim, or header joist or roof truss parallel to the braced wall panels shall be permitted to replace the blocking required by this section. Blocking shall not be required over openings in continuously-sheathed braced wall lines. In addition to the requirements of this section, lateral support shall be provided for rafters and ceiling joists in accordance with Section R802.8 and for trusses in accordance with Section R Roof ventilation shall be provided in accordance with Section R For Seismic Design Categories A, B and C and basic wind speeds less than 100 mph (45 m/s) where the distance from the top of the braced wall panel to the top of the rafters or roof trusses above is 91/4 inches (235 mm) or less, blocking between rafters or roof trusses shall not be required. Where the distance from the top of the braced wall panel to the top of the rafters or roof trusses above is between 91/4 inches (235 mm) and 151/4 inches (387 mm), blocking between rafters or roof trusses shall be provided above the braced wall panel in accordance with Figure R (1). 2. For Seismic Design Categories D0, D1 and D2 or basic wind speeds of 100 mph (45 m/s) or greater, where the distance from the top of the braced wall panel to the top of the rafters or roof trusses is 151/4 inches (387 mm) or less, blocking between rafters or roof trusses shall be provided above the braced wall panel in accordance with Figure R (1). 2. (remains unchanged). 13. Revise Section R and corresponding table as follows: R Applicability limits. The provisions of this section shall control the construction of exterior coldformed steel wall framing and interior load-bearing cold-formed steel wall framing for buildings not more than 60 feet ( mm) long perpendicular to the joist or truss span, not more than 40 feet ( mm) wide parallel to the joist or truss span, and less than or equal to three stories above grade plane. All exterior walls installed in accordance with the provisions of this section shall be considered as loadbearing walls. Cold-formed steel walls constructed in accordance with the provisions of this section shall be limited to sites subjected to a maximum where the basic design wind speed is not greater than of 110 miles per hour (49 m/s), the Exposure Category is B or C, and the a maximum ground snow load is not greater than of 70 pounds per square foot (3.35 kpa). TABLE R WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS a,b BASIC WIND SPEED (mph) AND EXPOSURE FRAMING CONDITION 85 B 90 B 85 C 100 B 90 C 110 B 100 C < 110 C
5 14. Revise Tables R (2) through R (31), and Tables R (1) through R (4) all the same way: BASIC WIND SPEED Exp. B TABLE R (2) a, b, c 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY 33 ksi STEEL MINIMUM STUD THICKNESS (mils) STUD 8-Foot Studs 9-Foot Studs 10-Foot Studs MEMBER SPACING Ground Snow Load (psf) SIZE (inches) Exp. C (Make same change for Tables R (3) through R (31), and Tables R (1) through R (4)) 15. Revise Footnote b in Table R603.8 as follows:. TABLE R603.8 HEAD AND SILL TRACK SPAN Footnote b. Head and sill track spans are based on components and cladding wind pressures speeds and 48 inch tributary span. 16. Revise Section R as follows: R Where the basic wind speeds are in excess of exceeds 100 miles per hour (45 m/s) and, Exposure C or D applies, walls shall be provided with wind direct uplift connections in accordance with AISI S230, Section E13.3, and AISI S230, Section F7.2, as required for 110 miles per hour (49 m/s), Exposure C 17. Revise Section R611.2 as follows: R611.2 Applicability limits. The provisions of this section shall apply to the construction of exterior concrete walls for buildings not greater than 60 feet ( mm) in plan dimensions, floors with clear spans not greater than 32 feet (9754 mm) and roofs with clear spans not greater than 40 feet ( mm). Buildings shall not exceed 35 feet ( mm) in mean roof height or two stories in height abovegrade. Floor/ceiling dead loads shall not exceed 10 pounds per square foot (479 Pa), roof/ceiling dead loads shall not exceed 15 pounds per square foot (718 Pa) and attic live loads shall not exceed 20 pounds per square foot (958 Pa). Roof overhangs shall not exceed 2 feet (610 mm) of horizontal projection beyond the exterior wall and the dead load of the overhangs shall not exceed 8 pounds per square foot (383 Pa). Walls constructed in accordance with the provisions of this section shall be limited to buildings subjected to a maximum where the basic design wind speed is not greater than of 130 miles per hour (58 m/s) Exposure B, 110 miles per hour (49 m/s) Exposure C and 100 miles per hour (45 m/s) Exposure D. Walls constructed in accordance with the provisions of this section shall be limited to detached one- and twofamily dwellings and townhouses assigned to Seismic Design Category A or B, and detached one- and two-family dwellings assigned to Seismic Design Category C.
6 18 Revise Tables R611.6(1) through R611.6(4) all the same way: TABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS (Make same change for Tables R611(2) through R611(4)) a, b, c, d, e BASIC MAXIMUM WIND SPEED (mph) MAXIMUM UNSUPPORTED WALL HEIGHT PER STORY (feet) 19. Revise Section R613.2 as follows: MINIMUM VERTICAL REINFORCEMENT BAR SIZE AND SPACING (inches) f, g Nominal h wall thickness (inches) Exposure Category B C D Top i Side i Top i Side i Top i Side i Top i Side i R613.2 Applicability limits. The provisions of this section shall control the construction of exterior structural insulated panel walls and interior load-bearing structural insulated panel walls for buildings not greater than 60 feet ( mm) in length perpendicular to the joist or truss span, not greater than 40 feet ( mm) in width parallel to the joist or truss span and not greater than two stories in height with each wall not greater than 10 feet (3048 mm) high. All exterior walls installed in accordance with the provisions of this section shall be considered as load-bearing walls. Structural insulated panel walls constructed in accordance with the provisions of this section shall be limited to sites where the basic subjected to a maximum design wind speed is not greater than of 130 miles per hour (58 m/s), the Exposure Category is A, B or C, and a maximum the ground snow load is not greater than of 70 pounds per foot (3.35 kpa), and the Seismic Design Category is Categories A, B, or and C. 20. Revise Tables R613.5(1) and R613.5(2) both the same way: TABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP LIGHT-FRAME ROOF ONLY (inches) BASIC WIND SPEED (3-second gust) (mph) Exp. A/B Exp. C SNOW LOAD (psf) MINIMUM STUD THICKNESS (mils) Wall Height (ft) Wall Height (ft) Wall Height (ft) Wall Height (ft) Wall Height (ft) Revise Section R as follows: R Applicability limits. The provisions of this section shall control the design of truss roof framing when snow controls for buildings not greater than 60 feet ( mm) in length perpendicular to the joist, rafter or truss span, not greater than 36 feet ( mm) in width parallel to the joist, rafter or truss span, not greater than two stories in height with each story not greater than 10 feet (3048 mm) high, and roof slopes not smaller than 3:12 (25-percent slope) or greater than 12:12 (100-percent slope). Truss roof framing constructed in accordance with the provisions of this section shall be limited to sites subjected to a maximum where the basic design wind speed is not greater than of 110 miles per hour (49 m/s), the Exposure Category is A, B or C, and the a maximum ground snow load is not greater than of 70 pounds per square foot (3.35 kpa). For consistent loading of all truss types, roof snow load is to be computed as: 0.7 pg.
7 22. Revise Section R as follows: R Applicability limits. The provisions of this section shall control the construction of cold-formed steel roof framing for buildings not greater than 60 feet ( mm) perpendicular to the joist, rafter or truss span, not greater than 40 feet ( mm)in width parallel to the joist span or truss, less than or equal to three stories above grade plane and with roof slopes not less than 3:12 (25-percent slope) or greater than 12:12 (100 percent slope). Cold-formed steel roof framing constructed in accordance with the provisions of this section shall be limited to sites subjected to a maximum where the basic design wind speed is not greater than of 110 miles per hour (49 m/s), the Exposure Category is B or C, and the a maximum ground snow load is not greater than of 70 pounds per square foot (3.35 kpa). 23. Revise Section R as follows: R Minimum roof rafter sizes. Roof rafter size and thickness shall be determined in accordance with the limits set forth in Tables R (1) and R (2) based on the horizontal projection of the roof rafter span. For determination of roof rafter sizes, reduction of roof spans shall be permitted when a roof rafter support brace is installed in accordance with Section R The reduced roof rafter span shall be taken as the larger of the distance from the roof rafter support brace to the ridge or to the heel measured horizontally. For the purpose of determining roof rafter sizes in Tables R (1) and R (2), basic wind speeds shall be converted to equivalent ground snow loads in accordance with Table R (3). Roof rafter sizes shall be based on the higher of the ground snow load or the equivalent snow load converted from the basic wind speed. 24. Revise Section R as follows: R Hip framing. Hip framing shall consist of jack-rafters, hip members, hip support columns and connections in accordance with this section, or shall be in accordance with an approved design. The provisions of this section for hip members and hip support columns shall apply only where the jack rafter slope is greater than or equal to the roof slope. For the purposes of determining member sizes in this section, basic wind speeds shall be converted to equivalent ground snow load in accordance with Table R (3). 25. Revise Section R as follows: R Application. Tile shall be applied in accordance with this chapter and the manufacturer's installation instructions, based on the following: Clay and concrete roof tiles shall be fastened in accordance with this section and the manufacturer s installation instructions. Perimeter tiles shall be fastened with a minimum of one fastener per tile. Tiles with installed weight less than 9 pounds per square foot (0.4 kg/m2) require a minimum of one fastener per tile regardless of roof slope. Clay and concrete roof tile attachment shall be in accordance with the manufacturer s installation instructions where applied in areas where the basic wind speed exceeds 100 miles per hour (45 m/s) and on buildings where the roof is located more than 40 feet ( mm) above grade. In areas subject to snow, a minimum of two fasteners per tile is required. In all other areas, clay and concrete roof tiles shall be attached in accordance with Table R Reason: This proposal is submitted by the ICC Building Code Action Committee (BCAC) The BCAC was established by the ICC Board of Directors to pursue opportunities to improve and enhance an assigned International Code or portion thereof. This includes both the technical aspects of the codes as well as the code content in terms of scope and application of referenced standards. Since its inception in July, 2011, the BCAC has held 6 open meetings and numerous workgroup calls which included members of the BCAC as well as any interested party to discuss and debate the proposed changes. Related documentation and reports are posted on the BCAC website at:
8 The purpose of this proposal is to coordinate terminology in the code. Figure R (A) supplies the basic wind speed, defined as the three-second gust speed at 33 feet ( mm) above the ground in Exposure C (see Section R ). This wind speed, derived from ASCE 7, is a design wind speed based on an extensive modeling process using historical data, wind characteristics and computer simulations. It is not necessarily the maximum wind speed that can be experienced by a site, nor does it suggest the maximum wind speed an element is capable of resisting due to factors of safety in material standards and design procedures. This proposal corrects references throughout the IRC to properly refer to basic wind speed. Cost Impact:????????????
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More informationHURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
More informationresearch report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute
research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 2006 American Iron and Steel Institute Residential Hip Roof Framing Using Cold-Formed Steel Members i
More informationSection A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
More information8/18/14. Introduction to. Framing. Terminology and Concepts
8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb
More informationBEAMCHEK EXAMPLES. RIDGE BEAM SIMPLE SPAN EXAMPLE No. 1 ACTUAL MATERIALS, LOADS AND CODE REQUIREMENTS MAY VARY. THIS IS AN ILLUSTRATION ONLY.
BEAMCHEK EXAMPLES TM NOTE: The BeamChek interface is often updated and buttons are occasionally relocated. The functions remain the same, but it may be necessary for you adjust between these examples and
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationCommon Errors in Truss Design
In today s competitive world of trusses, component manufacturers are always looking for ways to generate more efficient truss designs. Occasionally, truss designs need to be changed in order to be sealed
More information4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationBuilding Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationFormwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
More information1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.
Formulas: Formula Letters: H= Height BCY = Bank Cubic Yards L= Length CCY = Compact Cubic Yards P= Perimeter LCY = Loose Cubic Yards LF = Linear Feet or Lineal Feet BF = Board Foot or Feet SF = Square
More informationLoad Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE.
R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More information1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationTo learn more about PATH, please contact:
PATH (Partnership for Advancing Technology in Housing) is a new private/public effort to develop, demonstrate, and gain widespread market acceptance for the Next Generation of American housing. Through
More informationTHE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
More informationTYPICAL PATIO COVERS 111
City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin
More informationINTRODUCTION STRUCTURAL DESIGN
INTRODUCTION to STRUCTURAL DESIGN A Beginner s guide to Gravity Loads and Residential Wood Structural Design by Albert Hilton Cohen Copyright AHC 1998-2002 All rights reserved. No part of this publication
More informationCONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
More informationSignificant Code Changes to the 2009 International Residential Building Code
Significant Code Changes to the 2009 International Residential Building Code CHAPTER 1 SCOPE AND ADMINISTRATION R106.1.1 Information on Construction Documents Where required by the building official, all
More informationRegional and Site Assumptions This document is based on the following regional and site assumptions:
Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter or online approval,
More informationFeaturing TJ Rim Board and TimberStrand LSL
#TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load
More informationNAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05)
NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05) NAVAJO COUNTY GOVERNMENTAL COMPLEX P.O. BOX 668 HOLBROOK, ARIZONA
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationINFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 June 26, 1998 (Revised June 4, 2014) City Planning & Development - Development Services City of Kansas
More informationINTERNATIONAL RESIDENTIAL CODE 2006 Third Edition
WASHINGTON STATE BUILDING CODE CHAPTER 51-51 WAC INTERNATIONAL RESIDENTIAL CODE 2006 Third Edition Washington State Building Code Council Copies of the State Building Codes and complete copies of the 2006
More informationTo learn more about PATH, please contact:
PATH (Partnership for Advancing Technology in Housing) is a new private/public effort to develop, demonstrate, and gain widespread market acceptance for the Next Generation of American housing. Through
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationRESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationGeneral Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout
General Approach Sketch general structural layout Determine roof loading Determine required lumber dimensions Transfer load down the structure Structure Components Plants Structure Components Top Side
More informationONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS
ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS This package was prepared by the Meet & Greet Office 1002 Washington Avenue 1 st Floor Houston, TX 77002 Phone: 832-394-9000 TABLE OF CONTENTS
More informationLP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
More informationRB271 06/07 R807.1 RB272 06/07 R807.1. Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN
3. The use of asphalt shingles and other roof coverings has been successful over these composite insulation panels, so the extra details about vapor retarders, etc. can be eliminated. RB271 06/07 R807.1
More informationISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
More informationCITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
More informationSolar Panel Installations
Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.
More informationIntroduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
More informationThe Residential Code of New York State Instructor:
Introduction Lesson 1 The Residential Code of New York State Instructor: Introduction and Overview The International Residential Code altered with The New York State Enhancements is known as. Lesson 1:
More informationCPA Steel Stud Framing Page 1 of 11
CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationUL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC
UL 580 TEST REPORT Rendered to: ARMSTRONG WORLD INDUSTRIES SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC Report No.: Test Dates: 12/14/09 Through: 12/22/09 Report Date: 03/12/10 Expiration
More informationCustom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationStructural Design for Residential Construction
Structural Design for Residential Construction Cynthia Chabot, P.E. Chabot Engineering www.chabotengineering.com What is residential construction? One and two family dwellings Typically wood framed construction
More informationROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
More informationANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood.
CONSTRUCTION TERMINOLOGY ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood. ANCHOR BOLT: Heavy, threaded bolt embedded in the foundation to secure sill to foundation
More informationproviding documentation that validates the year of construction. Acceptable documents include
902. WINDSTM MITIGATION FEATURES A. For policies that cover the peril of Windstorm or Hail, a premium credit may be available if one or more of the following loss mitigation features or construction techniques
More informationChapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
More informationGeorgia Association of Home Inspectors
Georgia Association of Home Inspectors Standards of Practice for Framing Inspections OVERVIEW The purpose of the GAHI (Georgia Association of Home Inspectors) Standards of Practice for Framing Inspections
More informationDevelopment Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
More information2015 UCC Residential Code Update
2015 UCC Residential Code Update The Pennsylvania regulations related to Residential Construction codes changed effective January 1, 2016. The sections of the 2015 IRC that PA adopted as part of the UCC
More informationBuilding Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two
Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Factors governing type selection Economics not necessarily the one that requires the least structural
More informationMUNICODE SERVICES LTD.
The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationMAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
More informationSolar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings
Solar Water Heating and Solar Electric Generators Installed on Category: Residential Construction Revised: [Paul L. Scarlett], Director Responsible Bureau Section: Development Services Center 1900 SW Fourth
More informationDevelopment Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings
Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings H:/forms/handouts/bldg071.docx Shed and Garage Construction
More informationChapter 3 FOUNDATIONS AND FOUNDATION WALLS
Chapter 3 FOUNDATIONS AND FOUNDATION WALLS This chapter discusses foundations and foundation walls constructed using the two most common foundation materials concrete and masonry. Although the IRC permits
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationRoof Tutorial. Chapter 3:
Chapter 3: Roof Tutorial The majority of Roof Tutorial describes some common roof styles that can be created using settings in the Wall Specification dialog and can be completed independent of the other
More informationGYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
More informationROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
More informationTJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists
#TJ-4500 SPECIFIER S GUIDE TJi 110 TJi 210 TJi 230 TJi 360 TJi 560 JoiSTS WESTERN CANADA Featuring Trus Joist TJi Joists for Floor and Roof applications uniform and predictable lightweight for Fast installation
More informationSUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
More informationDEPARTMENT OF ACCOUNTING AND GENERAL SERVICES. Adoption of Chapter 3-185. Hawaii Administrative Rules SUMMARY
DEPARTMENT OF ACCOUNTING AND GENERAL SERVICES Adoption of Chapter 3-185 Hawaii Administrative Rules SUMMARY 1. Chapter 185 of Title 4, Hawaii Administrative Rules, entitled State Residential Code, is adopted
More informationINSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
More informationPole Building Estimate Number: 4992 12/2/2010 NORTH SIDE-EAVE SIDE 2 ELEVATION
NORTH SIDE-EAVE SIDE 2 ELEVATION SOUTH SIDE-EAVE SIDE 1 ELEVATION WEST SIDE-GABLE SIDE 2 ELEVATION EAST SIDE-GABLE SIDE 1 ELEVATION Wheeling Centurydrain Steel Roofing Metal Drip Edge Facia Board Facia
More informationCHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
More informationSECTION 3 ONM & J STRUCTURAL ANALYSIS
Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION
More informationTEXAS WINDSTORM INSURANCE ASSOCIATION BUILDING CODE FOR WINDSTORM RESISTANT CONSTRUCTION 27 TAC 5.4008
TEXAS WINDSTORM INSURANCE ASSOCIATION BUILDING CODE FOR WINDSTORM RESISTANT CONSTRUCTION 27 TAC 5.4008 Amendments Effective June 1, 2002 DEVELOPED BY THE TEXAS DEPARTMENT OF INSURANCE I TEXAS WINDSTORM
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More information2014 FLORIDA BUILDING CODE
MINIMUM REQUIREMENTS FOR NEW 1 & 2 FAMILY RESIDENTIAL STRUCTURES (ALL PLANS MUST BE 22 X 36 ) WIND BORNE DEBRIS AREA Is the proposed structure located in the wind borne debris area? If yes, one of the
More informationSINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
More informationBasic Requirements for Residential Plan Review _
Basic Requirements for Residential Plan Review _ Below you will find the basic requirements for your plan submittal. General: Drawn to scale Plan Size minimum: 9 x 12 Designer, Engineer, or Architect name,
More informationDetached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
More informationFOUNDATIONS CHAPTER 4
CHAPTER 4 FOUNDATIONS SECTION R401 GENERAL R401.1 Application. The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for all buildings. Wood foundations
More informationCH. 2 LOADS ON BUILDINGS
CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends
More informationWind Mitigation Discount Plan
Wind Mitigation Discount Plan Louisiana Hurricane Loss Mitigation Survey Form Inspector Instructions The purpose of these instructions is to provide guidance to certified inspectors on how to properly
More informationPerforated Shearwall Design Method 1
Perforated Shearwall Design Method 1 Philip Line, P.E., Bradford K. Douglas, P.E., American Forest & Paper Association, USA Abstract Wood frame shearwalls are traditionally designed using full-height shearwall
More informationHigh Wind & Hail Standards
2012 Edition High Wind & Hail Standards FORTIFIED is a program of the Insurance Institute for Business & Home Safety Table of Contents Program Overview and Definitions 5 Goals 5 Objectives 6 Designation
More informationINFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 (June 26, 1998, Revised March 26, 2009) City Planning & Development - Development Services City of Kansas
More informationDEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationCity of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
More informationRESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationHow To Design A Post Tensioned Deck For A Building
SAMUEL ÁVILA STRUCTURAL OPTION FACULTY CONSULTANT: THOMAS BOOTHBY UNIVERSITY OF CENTRAL FLORIDA S ACADEMIC VILLAGES ORLANDO, FL THESIS PROPOSAL EXECUTIVE SUMMARY DECEMBER 12, 2005 Introduction: The University
More information1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)
TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.
More information