The Residential Code of New York State Instructor:
|
|
|
- Theodore Carpenter
- 10 years ago
- Views:
Transcription
1 Introduction Lesson 1 The Residential Code of New York State Instructor: Introduction and Overview The International Residential Code altered with The New York State Enhancements is known as. Lesson 1: Introduction CHAPTER XXX III Sub Chapter A 1220 Residential Code 1221 Building Code 1222 Plumbing Code 1223 Mechanical Code 1224 Fuel Code 1225 Fire Code 1226 Property Maint. Introduction and Overview So What is the? A comprehensive, stand alone residential construction code, that establishes minimum i regulations for the construction of one-and two-family dwellings and town homes using prescriptive provisions Introduction and Overview When should the be used? New Construction of: One and two- family dwellings Multiple single family dwellings (townhouses) Under 3 stories in height Providing separate means of egress from each dwelling unit Introduction and Overview The Residential Code should also be used to provide minimum requirements for: Additions Alterations Movementt Repairs Replacement of equipment Demolition or Removal 1-1
2 Lesson 1: Introduction Introduction and Overview What is in the? The includes prescriptive provisions for Conventional Light Frame Construction Wood Light-Gage g Steel Construction Metal studs, joists and rafters Masonry Construction Block Concrete Construction Poured in-place Introduction and Overview The Big Picture Course 9A Permits and legal avenue to do our jobs Building Code, State Laws and Regulations Course 9B Fire Safe Design Course 9C Inspections of existing buildings Fire Code and Property Maintenance Code Course 9D Basic construction principles Energy Code, Fuel Gas, Mechanical, Plumbing Code, Systems Introduction and Overview The Big Picture (continued) This course (9E) will address Residential Structures using a prescriptive format Residential Code Course 9F will cover General Building Construction Building Code and Fire Code Course Materials Student Workbook Note taking Supplemental information in the appendix Single Family Plans Yours to keep BUT DON T use them to build Plan Review Checklist 2 sets in the back of the workbook Introduction and Overview Course format We will follow a 4 step process 1. The instructor will cover code sections through lecture 2. Using a plan review sheet and a set of plans the class will do a plan review covering the code sections from the lecture 3. The class and the instructor will perform virtual inspections through slides 4. The class will take a final exam Introduction and Overview Are there any Questions or concerns at this point 1-2
3 Overview The Book Lesson 2: Overview THE OF NEW YORK STATE Lesson 2 The Residential Code of New York State Table of Contents Provides us with a layout of the book broken down by Part Part III Chapter Chapter 3 Section Section R311 Let s take a look at the Table of Contents Organization Part I Administration Chapter 1 General requirements Part II Definitions Chapter 2 Definitions Part III Building Planning and Construction Chapters 3 through 10 Part IV Energy Conservation Chapter 11 Part V Mechanical Chapters 12 through 23 Part VI Fuel Gas Chapter 24 Part VII Plumbing Chapters 25 through 32 Part VIII Electrical Chapters 33 through 42 Part IX Referenced Standards Chapter 43 Part X Appendices A through K Index The Division of the Chapter 3 Performance requirements Sets criteria for use of prescriptive chapters Chapters 4 through 42 Prescriptive (specification) construction requirements All the How to information PLANS DRAWINGS and SPECIFICATIONS DRAWINGS are QUANTITATIVE (How many) SPECIFICATIONS are QUALITATIVE (What type) Together these documents DESCRIBE a structure or building 2-1
4 Lesson 2: Overview The Project The Plans Cover Sheet Plan view Cover Sheet Avalon Garage Left Avalon Garage Right Locates the building on the property Locates the Water line Septic line Site utilities Provides setback information The Plans Plot Plan Sheet S-1 The Plans Site Location The Plans Topographic Information Subdivision Map Provides a reference drawing to help locate the building site Shows properties that surround the building site and their relationship to it Contour Lines 2-2
5 The Plans Foundation Plan A-1 Dimensioning Systems The Plans First Floor Plan Window schedule Door schedule General notes Fireplace sizes Lesson 2: Overview A3.02L The Plans Second Floor Plan A3.03L The Plans Second Floor Plan A3.03L The Plans Section A representation of an object as it would appear if cut by an imaginary plane, showing the internal structure. The Plans Cutting Plane Detail CUT PLANE BS-B/A3.04B/A3 A representation of a building, or portion thereof, drawn as if it were cut vertically to show the interior. VIEW ANGLE LOCATION (pg.#) 2-3
6 Lesson 2: Overview The Plans Building Sections A3.04L The Plans Elevation Views 1. A drawing showing the vertical elements of a building, either exterior or interior, as a direct projection to a vertical plane. 2. The vertical distance above or below some established reference level. The Plans Elevation Views A3.05 and A3.06 The Plans Floor Framing Plans A-7 and A-8 Optional window master bedroom The Plans Floor Framing Plans A-7 and A-8 The Plans Roof Framing Plans A3.09L Engineered Lumber TJI joist Microlam WHAT? NO 2X12 S? 2-4
7 The Plans Electrical Details Sheet E-1 Lesson 2: Overview The Plans Electrical Details E-1 The Plans Systems Basic systems were covered in Course 42 Plumbing Heating Electrical Fuel Gas We will check for compliance with a plan review and verify through inspections Education Law Requires design professionals seal and signature on Drawings PHASE 3 KEY PLAN DATE 9/12/80 JOB 3 The Sommerville Bldg.. 20 Swan St.. Menands, NY PLAN REVIEW SHEETS Plan Review Sheet A plan review sheet should be used to conduct a plan review A good plan review sheet will lead you to important code sections that should not be overlooked A plan review sheet should never be used in place of the book A plan review should never be considered to be all inclusive 2-5
8 Lesson 2: Overview Plan Review Sheet For ease in identifying sections of the code needed for a particular plan review, the review sheet has been broken into 6 parts Form 1 Master Form 2 Foundations Form 3W Wood frame construction Form 3S Steel frame construction Form 3M Masonry or Concrete construction Form 4 Roof construction Form 1 Fill out with info from application { Top row based on local conditions Bottom row to verify information on the plans Check off forms used for review Lesson 2 Conclusion You have now seen the tools we have to work with The Residential Code The plans for a single family residence The plan review sheet In the next lesson We will start to put these items and YOU to work 2-6
9 Lesson 3: Building Planning R101.2 Scope The Residential Code shall apply to: The of NEW YORK STATE Lesson 3 Chapter 3 Building Planning Detached One-and two-family dwellings and Multiple single-family dwellings (townhouses) Not more than 3 stories in height Separate means of egress Accessory structures What is a Townhouse? Would this work? See definition Townhouse NO! R101.2 Scope This code also regulates Bed and Breakfast Conversion to BB in Appendix J NY State designated facilities Community Residences Hospice Residences Factory built homes Manufactured Homes Mobile Homes Modular Homes R102 Applicability R102.8 General Rules Existing Structures Most restrictive requirement ALWAYS applies In a conflict, most Specific code requirements rule In a conflict between the Code and a Standard, the Code rules Legal occupancy permitted to continue, with exceptions Additions, alterations, repairs comply with Code Code NOT applicable to existing portions of the structure unless specifically stated 3-1
10 Lesson 3: Building Planning It s NOT in there!! What You Won t Find in the : Construction type Maximum building area 3 story maximum height If >3 stories, the Building Code applies Prescriptive Chapters MAY limit Height and/or size Habitable space location limitations Part III Building Planning and Construction CHAPTER 3 BUILDING PLANNING Sections R301 through R324 Topic 1: Structural Design Criteria Topic 2: Minimum Requirements for Habitability Fire Safety Fire Protection Chapter 3 - Building Planning Prescriptive Topic 1 Design Criteria Sets conditions for use of the PRESCRIPTIVE Chapters The intent of this code is to allow the design and construction of a structure using gproven and recognized methods and materials. If all the elements of the light frame construction comply with the code, no additional engineering is required! R301.1 Design All buildings and structures must be designed to safely support all loads Dead load Live load Roof, Flood, Snow, Wind and Seismic loads Loads must be transferred R301.1 Design If Structural elements exceed the limits of Chapter 3 Or are not specifically listed in, the Residential Code those elements shall be designed in accordance with accepted engineering practice 3-2
11 Lesson 3: Building Planning TABLE R301.2(1) The code enforcement official will complete based on local conditions CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD i WIND Speed d (mph) SEISMIC DESIGN CATEGORY e Snow Loads (R ) Based on Ground Snow Load Student Research This building will be located in GLENS FALLS (Warren County southern most part) Use the FOOTNOTES to complete the first line of the Table < 70 psf - OK to use prescriptive chapters > 70 psf - Accepted engineering practice *** Informational Note *** Prescriptive Tables for Rafters are based on Ground Snow Load adjustment for roof conditions are built in! SNOW MAP Section R Wind Limitations Buildings shall be limited by wind speed as defined in Table R301.2(1) Basic wind speed shall be determined by Figure R301.2(4) Footnote i: Adjust ground snow load at locations above 1000 feet elevstion GROUND SNOW LOAD i WIND Speed d (mph) SEISMIC DESIGN CATEGORY e Basic Wind Speed 90 Figure 301.2(4) Special Wind Region R Exposure Categories Exposure A Large city center. Not typical of Residential Code building Exposure B (This is presumed unless site meets another category) Urban/suburban, low-rise construction, fairly dense Exposure C Suburban/rural with some topological differences Hurricane prone regions Exposure D Flat, unobstructed areas with wind flowing over water (Municipalities on Lake Ontario or Lake Erie) 3-3
12 Lesson 3: Building Planning Wind Design - Nassau and Suffolk High Wind and Hurricane Prone areas R Design Criteria Building design MUST comply with 1 of 5 listed methods: AFPA, SBCC, ASCE-7, Cold-formed steel, Concrete R Internal Pressure Protect Openings OR Design as a Partially Enclosed Building Exception for Wood Structural Panels Seismic Design Category What did you learn in Course 9D? You will provide the information on table R301.2(1) to establish the minimum acceptable structural requirements GROUND SNOW LOAD i WIND Speed d (mph) SEISMIC DESIGN CATEGORY e R Seismic Provisions ONLY applies to Seismic Design Categories C and D NY has several C and D category areas! Detached one- and two-family in category C are EXEMPT Additional seismic requirements found in prescriptive construction chapters Figure R301.2(2) Table R301.2(1) SUBJECT TO DAMAGE FROM Weathering a Frost line depth b Termite c Table R301.2(1) SUBJECT TO DAMAGE FROM Weathering a Frost line depth b Termite c Weathering NYS is entirely in the severe zone Concrete requirements Frost line depth Based on local conditions Chapter 4 Footing and foundations Termite Protection and prevention Based on figure R301.2(6) (Termite) Or known local conditions 3-4
13 Lesson 3: Building Planning R320 Protection Against Termites Infestation probability Figure 301.2(6) Control to be provided by: Chemical soil treatment Termite baiting system AWPA complying pressure treated wood Field cut ends, notches, and drilled holes require retreatment in field Naturally termite-resistant woods Plastic or metal physical barriers (shields) Or any combination of the methods above Table R301.2(1) ICE SHIELD UNDERLAYMENT REQUIRED g FLOOD HAZARDS f Ice Shield Underlayment Must be provided on all roof eaves in N.Y.S. to a distance of 24 inside the exterior wall of the building line Flood Hazards Based on FIRM maps Design Flood elevation PLUS Freeboard of 2 R324 Flood-Resistant Construction Requirements for areas prone to flooding Protection of equipment and systems Elevation of living spaces Foundation design and construction R324 Flood-Resistant Construction As-built elevation certification Licensed surveyor or design professional A or V Zone requirement compliance R324.2 Flood Hazard Areas (A Zones) R324.3 Coastal High Hazard Areas (V Zones) Certification by design professional required R319 Protection Against Decay Construction in areas subject to decay See Figure 301.2(7) Approved species/grade of lumber AWPA pressure preservative treated or decay-resistant heartwoods Required if contact with, or proximity to Ground, Concrete or Masonry Fasteners Hot-dipped galvanized steel, stainless steel, silicon bronze or copper Chapter 3 - Building Planning Topic 2 Requirements for: Habitability Fire Safety and Protection 3-5
14 Lesson 3: Building Planning R302 Exterior Wall Location Fire Safety and Protection Exterior walls Table R302.1 Does not apply in walls that are perpendicular Projections limited to 12 into space where openings are prohibited Exceptions Sheds and playhouse if Permit is Not Required Detached Garage allowed within 2 Table R302.1 MINIMUM FIRE EXTERIOR WALL ELEMENT MINIMUM FIRE- RESISTANCE RATING SEPARATION DISTANCE (Fire-resistance 1 hour with exposure Walls rated) from both sides 0 feet rated) (Not fire-resistance 0 hours 5 feet Projections (Fire-resistance rated) 1 hour on the underside 4 feet (Not fire-resistance rated) 0 hours 5 feet Not allowed N/A < 3 feet Openings 25% Maximum of Wall Area 0 hours 3 feet Unlimited 0 hours 5 feet Comply with Section Penetrations All R317.3 < 5 feet None required 5 feet R302 Exterior Wall Location Fire Safety and Protection Location on lot 1 hr rating if < than 5 fire separation distance Openings not permitted, (some exceptions) R303 Habitability Light and Ventilation - R303 Natural light Minimum glazing area = 8% of the floor area Natural ventilation Minimum openable area = 4% of the floor area Allowance to borrow from adjacent rooms R303 Natural Light and Ventilation Natural Light Calculate total surface area of all glazing in the room Natural Ventilation Calculate the total area of all doors, windows and louvers in the room that open to outside air R303 Borrowed Light and Ventilation Living Room Dining Room 1. Calculate total floor area for both rooms 2. Windows in living room must equal 8% of total floor area 3. Openable windows in living room must equal 4% of total floor area 4. Opening criteria in R303.2 Adjoining rooms 3-6
15 Lesson 3: Building Planning Step #1: Find this window chart in the appendix of your workbook 2 pages: Vent Units Fixed and Transom Light and Ventilation Example Bedroom #2 168 SF Req d light is 8% Req d ventilation 4% Window is E From the Window Schedule PTD units E Plan Review Using the Pella Window information / / R50 Bedroom S/F S/F 2x7.8=15.6SF 6.72 S/F 2x4.2=8.4SF / / R50 Types of Safety Glass Tempered Use this window chart in the appendix of your workbook AND (click) 3-7
16 Types of Safety Glass Laminated Safety Glass Lesson 3: Building Planning Types of Safety Glass Strengthened Glass Heat Strengthened Glass Chemically Strengthened Glass Hazardous Locations NY Identifying Safety Glazing R309 Garages and Carports Fire Safety and Protection Garages and Carports No openings to sleeping rooms Door assembly must be ¾ hour rated Self closing Duct work in garage area must be Min 26 gage steel Have NO openings in garage area R309 Garages and Carports Fire Safety and Protection Garages and Carports Separation must be provided Vertically Horizontally Separation must have a ¾ hour fireresistance rating Or meet the requirements of the exception 3-8
17 Lesson 3: Building Planning R310 Escape/Rescue Openings Fire Safety and Protection Emergency Escape and Rescue Openings Required from: Basements with habitable space Every sleeping room R310 Escape/Rescue Openings Minimum Dimensions Minimum openable area 5.7sq.ft. (see exception) Minimum opening height 24 Minimum opening width 20 Maximum sill height of 44 Must be openable without keys or tools R310 Escape/Rescue Openings Window Wells Permanent ladder or steps if deeper than 44 Minimum width of 36 Minimum 36 horizontal projection Minimum net area 9 SF Maximum 44 sill height R311 Means of Egress Fire Safety and Protection Hallway width 3-0 minimum Doors One swinging exit door from dwelling to exterior Minimum of 3 0 width, 6 8 height Operable without key, tool or special knowledge R311 Means of Egress Space under stairs Stairways Headroom Riser height Tread width Riser height plus nosing Tread width R312 Guards No passage of 4 sphere 30 or more Required when: 30 or greater elevation change Open side of stairs exceeding 30 Guard opening limitations: Balustrade can t allow passage of a 4 sphere No passage of 6 sphere Tread opening can t allow passage of a 6 sphere 4 3/8 allowed here 3-9
18 Lesson 3: Building Planning For more Stair Construction Details R313.1 Smoke Alarms Fire Safety and Protection Single and multiple-station smoke alarms shall be installed in Each sleeping room Outside each separate sleeping area In each additional story Power source Hard wired and battery back up R313.4 CO Alarms Fire Safety and Protection Required Locations Any story having a sleeping area Any story with a CO source Normally hardwired and interconnected R313.5 Sprinkler Systems Fire Safety and Protection Three story above a basement NFPA 13D sprinkler system Fire Safety and Protection Lesson 3 Summary Dwelling Unit Separation R317 Must have minimum 1 hour rating (exception) Must be Structurally independent All supporting structural elements must have same rating Must be provided in Two-Family Dwelling Townhouse Separations Chapters 1, 2 and 3 Administration, Definitions, Building Planning Performance requirements Next lessons Chapters 4 through 10 Prescriptive Construction Requirements Specific to building components and systems 3-10
19 Lesson 4: Foundations Section R401 THE OF NEW YORK STATE Lesson 4 Chapter 4 Foundations R401.1 Application Use this chapter to design and construct Foundations Foundation spaces Wood foundations use AF&PA Permanent Wood Foundation Design Specification. See exceptions R401.2 Requirements Must carry all loads Transmit loads Be supported by proper soils R401.3 Drainage Surface Drainage to storm sewer approved collection point Final grade shall pitch at least 6 within the first 10 of foundation R401.4 Soil tests shall be required If soil conditions are unknown If soils are known to be of poor quality R In lieu of a full geotechnical evaluation the load bearing values in table R shall be assumed Table R405.1 R402 Materials R402.1 Wood Foundations R Fasteners R Wood treatment R Concrete Compressive strength Air entrainment See Table R
20 Lesson 4: Foundations Table R402.2 Table R402.2 Minimum Specified Compressive Strength of Concrete TYPE OR LOCATION OF CONCRETE CONSTRUCTION Basement walls, foundations and other concrete not exposed to the weather Basement slabs and interior slabs on grade, except garage floor slabs Basement walls, foundation walls, exterior walls and other vertical concrete work exposed to the weather Porches, carport slabs and steps exposed to the weather, and garage floor slabs Minimum Specified Compressive Strength a (F c ) Weathering Potential b Severe 2,500 c 2,500 c 3,000 d 3,500d, e, f R403 Footings All exterior walls shall be supported by Continuous footings Foundation Footing must sized to support all loads based on the soil characteristics Footings must be on undisturbed soil or engineered fill R Minimum Footing Size Spread footings Minimum 6 thick Width (W) Table R403.1 Projection (P) Minimum 2 Max. thickness of footing Pier footing size Based on tributary loads Figure 403.1(1) R Minimum Footing Size Width (W) shall be determined by TABLE R403.1 Minimum Width of Concrete or Masonry Footings (inches) a LOAD-BEARING VALUE OF SOIL (psf) 1,500 2,000 3,000 4,000 Conventional light-frame construction 1-story story story brick veneer over light frame or 8 hollow concrete masonry 1-story story story solid or fully grouted masonry 1-story story story R Spread footings Supporting Piers and Columns Footings thickness Minimum 6 Footing width Sized to carry load Capable supporting load on the soil Seismic Reinforcing Concrete footing in Seismic Design Categories D 0, D 1 and D 2 Shall have reinforcement Reinforcement shall be min of 3 from bottom of footing 4-2
21 Lesson 4: Foundations R Minimum Depth Below frost line in Table R301.2(1) 12 min. below undisturbed ground Minimum depth exceptions: Frost-protected footings in R403.3 ASCE 32 (Frost Protected Shallow Foundation) Footings/foundations on solid rock SUBJECT TO DAMAGE FROM Weathering a Frost line Depth b Termite c Insert Frost Depth here R Minimum Depth Frost protection. buildings and structures shall be protected from frost Exceptions: Free standing accessory structures 600 SF or less, LIGHT-FRAMED CONSTRUCTION 400 SF or less, of OTHER THAN LIGHT-FRAMED Decks adjoining but More Footing Details Slope Top of footings must be level Bottom surfaces no greater than 1 to 10 slope Foundation anchorage Anchor bolt spacing Size, depth Other fasteners R Footings on or adjacent to slopes R Building clearance from ascending slopes R Footing setback from descending slopes R Foundation elevation R Alternative setback and clearances H/3 BUT NEED NOT EXCEED 40 FT MAX H/2 BUT NEED NOT EXCEED 15 FT MAX R Foundations in Expansive Soils Foundations and floor slabs for buildings located on expansive soils shall be designed d in accordance with section of the Building Code of New York State R404 Foundation Walls R404.1 Concrete and Masonry Foundations: R Masonry R Concrete Typical acceptable wall designs from: R Tables in Code OR listed ACI, NCMA, ASCE or TMS Standards Engineered design required when: Hydrostatic pressure from ground water Unbalanced backfill against unsupported walls 4-3
22 Lesson 4: Foundations R Foundation Tables Foundation Tables Use the appropriate table Table R (1) Plain Masonry Table R (2) 8 Reinforced Masonry Table R (3) 10 Reinforced Masonry Table R (4) 12 Reinforced Masonry Table R (5) Concrete Foundation Walls Terminology (Footnote) Unbalanced backfill The height difference between exterior and interior ground levels Measured from exterior finish grade to top of interior floor/ground level Backfill requirements Top of finished foundation must be 4 above finish grade for brick veneer 6 above grade for all other finishes Backfill shall only placed against walls when The wall has achieved proper strength and has been anchored to the floor above Has been braced to prevent damage R405 Foundation Drainage Requires footing drains with an exception R406 Waterproofing/Dampproofing Damp proofing for all foundation walls Parging with bituminous coating Waterproofing for high water table areas Membrane protection R407 Columns R408 Under floor space Wood columns Protected from decay Steel columns Protected against corrosion Structural requirements Shall be restrained to prevent movement 4 x4 wood 3 standard pipe Crawl space requirements Must be ventilated See for sizing Must have access Minimum 18 x24 Shall be flood resistant 4-4
23 Lesson 5: Floors FLOORS LESSON 5 Chapter 5 covers 4 types of floor systems Wood floor framing Wood floors on the ground Steel floor framing Concrete slabs on the ground CHAPTER 5 FLOORS FLOORS Design and construction of ALL floors Including attics with mechanical/plumbing equipment Must comply with appropriate section Because they are the most common types used in NYS we will concentrate on Wood floor systems Concrete slabs on grade R Loads Accommodate loads in accordance with R301 Table R301.5 Minimum Uniformly Distributed Live Loads USE LIVE LOAD Attics with limited storage g,h 20 Attics without storage b 10 Decks e 40 Exterior balconies 60 Fire escapes 40 Guardrails and handrails d Guardrails in-fill components f Passenger vehicle garages a 200 i 50 i 50 a Rooms other than sleeping rooms 40 Sleeping rooms 30 Stairs 40 c R502 Wood Floor Framing Identification All dimensional lumber must have The grade mark of a grading or inspection agency Or An approved certificate of inspection in compliance with DOC PS 20 Grade Mark examples EXCEPTION: Rough sawn lumber 5-1
24 Lesson 5: Floors Rough Sawn Lumber Exception: Rough Sawn Lumber will be allowed for use in construction in one of two ways: Treated Lumber Identification Treated dimensional lumber must also bear a grade stamp and quality mark 1. If sold directly to consumer or builder 2. If the lumber comes with a letter from the sawyer stating the lumber is equal to # 2 grade lumber Wood Floor Framing Wood Floor Framing IDENTIFICATION: The grade mark must also be visible on all End jointed lumber Prefabricated wood I joists Must comply with the appropriate regulating standards Structural log members. Stress graded d, OR Certificate of Inspection as to species and grade Wood Floor Framing Must be Designed, Constructed and Inspected to Requirements q of Chapter 5 Figure R502.2 R319 Protection against decay R320 Protection against termites Figure
25 Lesson 5: Floors DECKS DECKS Deck live loads must be as shown in Table Where decks are designed with a cantilever, the uplift forces must be equal to the loads Table R301.5 Minimum Uniformly Distributed Live Loads USE LIVE LOAD Attics with limited storage g,h 20 Attics without storage b 10 Decks e 40 Exterior balconies 60 Fire escapes 40 Guardrails and handrails d 200 i Where supported by attachment to an exterior wall decks Shall be positively anchored (bolts) Shall be designed d for vertical loads Shall be designed for lateral loads If connections can t be inspected, deck must be self supporting Allowable Joist Spans Tables R (1) and (2) Allowable Spans for Common Species Table R (1) for 30 psf Live load Sleeping and attic areas Table R (2) for 40 psf Live load Other floor areas Floor Joist Span Examples Given: Sleeping area R Floor Cantilevers Common lumber (solid sawn) Appropriate table? Table R (1) 2 x 6, Spruce-pine-fir, grade #2 at 16 o.c. Allowable Span? Cantilevers shall not exceed the nominal depth of the joist 2 x12 The ratio of back spans to cantilever must be at least 3 to 1 36 min 12 max 5-3
26 Lesson 5: Floors R Floor Cantilevers In limited application, up to a 70 lb ground snow load. Single story cantilevers may also be constructed t using Table R (1) R50233(1) Exterior Balcony uses Table R (2) All others will require engineer certification R502.4 Joists Under Bearing Partitions Joists under bearing partitions must be sized to support loads If framed for pipe or duct passage must be solid blocked 4 o.c. R502.5 Allowable Girder Spans Girders constructed of dimensional lumber shall not exceed values in tables R502.5(1) 5(1) Girder and header spans for exterior bearing walls R502.5(2) (left out is a typo) Girder and header spans for interior bearing walls Girder Span Measurements TABLE R502.5(1) Girder Spans a and Header Spans a for Exterior Bearing Walls GROUND SNOW LOAD (psf) e Building width c (feet) GIRDERS AND HEADERS SUPPORTING SIZE Span NJ d Span NJd Span NJd Span NJd Span NJ d Span NJd Span NJd Span NJd Span NJd Roof and ceiling Roof, ceiling and one center bearing floor Roof, ceiling and one clear span floor Roof, ceiling and two centerbearing floors R502.6 Bearing Requirements Joists, beams, girders 1.5 bearing on wood or metal 3 bearing on masonry or concrete Other options: 1 x 4 ribbon strip or hangers 5-4
27 Lesson 5: Floors Floor systems Framing shall lap a minimum of 3 Shall be nailed with minimum of 3-10d nails OR Must be provided with a wood or metal splice Joist Framing Framing into wood girders Approved framing anchors OR Nail in place and support on 2 x 2 (nominal) ledger DRILLING AND NOTCHING Fig Cutting, Notching and Drilling Structural floor framing using sawn lumber can only be cut, notched, or drilled in accordance with figure Structural floor framing using engineered systems Glue lams I-joists Trusses Can only be cut, notched, or bored if such altering is specifically considered in the design of the member R Framing of Openings Header joists 4 feet or less need not be doubled R Framing of Openings Header joists Over 4 must be doubled Over 6 require approved hangers Tail joist Over 12 need a hanger or ledger at header 5-5
28 Lesson 5: Floors R Wood Trusses Must be Engineer designed and must have all certification documentation Temporarily braced during construction Permanently braced per specifications Must NOT be Site altered in any way without approval of a design professional Installed if damaged without approval of a design professional R Draftstopping Must be provided if concealed spaces exceed 1000 sq. ft. (interconnected) Typical ways to produce this scenario Suspended ceiling under floor framing Using open web trusses to frame floor Draftstopping must be constructed using an approved material as described in the code R Wood Structural Panels All Wood Structural Panels (Plywood) must be identified by a grade stamp Span Rating R503 Floor Sheathing Wood structural panels use Tables R (1) and R (2) Min. Nominal Thickness Allowable Live Load (PSF) h, l Maximum Span (inches) d Load (PSF, at maximum span) Maximum Span (inches) Roof f Sheathing e 16" o.c 24" o.c W/edge WO/edge Total Live Subfloor j Span Span support support Load Load 12/0 5/ /0 5/ /0 5/ /0 3/ g /16 7/ /16 15/32, 1/ h R506 Concrete Floors (On Ground) 3.5 minimum slab thickness IF expansive soil - R (Comply with Building Code Section ) Compressive strength - R ,500 psi 4 base course if slab is below grade Vapor retarder between slab and base R506 Concrete Floors (On Ground) Reinforcement support. from the center to upper one third of the slab for the duration of the concrete placement. 5-6
29 Lesson 5: Floors First Floor Framing Reading the Plans NON-Prescriptive framing First Floor Framing Reading the Plans Materials - Joists Engineered Lumber Follow manufacturer s instructions TJI TrusJoist floor and ceiling joists Microllam LVL beams and girders Locator Joist identifier for location First Floor Framing Reading the Plans First Floor Framing Reading the Plans Materials - Girders Joist Locator Connection Detail MicroLam First Floor Framing Reading the Plans Location First Floor Framing Reading the Plans Symbol Legend Beam label Bearing required 5-7
30 Lesson 5: Floors First Floor Framing Reading the Plans Level Notes Scale First Floor Framing Manufacturer s Specs Loading Flooring Spacing First Floor Framing Manufacturer s Specs TJI/Pro 120TS Span Table First Floor Framing Manufacturer s Specs Detail A2 First Floor Framing Manufacturer s Specs Detail B1 TJI Cantilever Details Manufacturer allows load bearing cantilevers up to 2 Non load bearing cantilevers up to 4 See 3 details for load bearing cantilevers 5-8
31 Lesson 5: Floors Builders Guide Builders Guide Check on job site for proper handling of materials Be sure all bracing both temporary and permanent are installed properly Holes in TJI Joists To check compliance on our building you must use the TJI hole chart Note: Closer to bearing point smaller hole allowed Mid span larger holes allowed No cutting or drilling top or bottom cord First Floor Framing Builders Guide First Floor Framing Builders Guide Plan Review Exercise Use plan pages A-7 and A-8 Complete all applicable sections of Item #1 of plan review form #3W 5-9
32 Lesson 6: Wall Construction Lesson 6 Chapter 6 Wall Construction Comply with appropriate section R602 Wood Wall Framing R603 Steel Wall Framing Depicts code provisions for wood frame systems Figure R602.3(1) Figure R602.3(2) Fasteners Provides Additional framing details for wood frame construction Tables R602.3(1) through R602.3(4) Fastener Schedule for Structural Members Examples: Ui Using table tbl (1)fidth find these examples Top or sole plate to stud,end nail 2-16d (3 1/2" x 0.135") fasteners. Built-up header, two pieces with ½ spacer 16d (3 1/2" x 0.135") fasteners at 16 o.c. along each edge Table Fastener Schedule Using the Correct Fasteners Table R602.3(1) identifies common nails for fastening sheathing materials to framing Be sure the fasteners used on the job site are Common nails Equal or better 6-1
33 Lesson 6: Wall Construction R Stud Spacing Table R Table R602.3.(5) provides the prescriptive requirements stud spacing in bearing walls up to 10 in height Bearing stud walls over 10 in height Conform with table R R602.4 Interior Load-bearing Walls R602.6 Drilling and Notching Studs Interior load-bearing walls shall be Constructed Framed Fireblocked As specified for exterior walls Fig (1) EXCEPTION Drilling and notching of top plates R602.7 Headers Fig Headers in load bearing walls must comply with Tables R502.5(1) and (2) If top plate of a bearing wall is notched or cut by more than 50% (as for the installation of piping or ductwork) strapping must be installed as shown above REMEMBER? 6-2
34 Lesson 6: Wall Construction R602.8 Fireblocking Requirements R602.8 Fireblocking Requirements Concealed stud spaces Ceiling and floor levels Horizontally at 10 intervals Connection between wall cavity and soffit areas Drop ceiling locations R602.8 Fireblocking Requirements At cove or trayed ceiling locations R602.8 Fireblocking Requirements At the top and bottom of stair stringers At openings around tubs to close off connections between floors At openings around pipes, ducts,vents at ceiling and floor levels R602.8 Fireblocking Requirements Fireblocking Requirements Noncombustible fireblocking must be provided at ceiling and floor levels around chimneys and flues R Materials Acceptable firestopping materials include Solid 2 blocking (nominal) Two layers of 1 solid blocking ¾ plywood or particle board Fiber glass or mineral wool Must be secured in place Must completely fill the cavity for a dimension of
35 Lesson 6: Wall Construction R Wall Bracing Definitions: Review from 9D Braced Walls Lines A series of braced wall panels constructed in accordance with R for wood or R603.7, R for steel to resist racking Braced Wall Panel A section of braced wall line constructed in accordance with R for wood or R603.7 or R for steel, which extends the full height of the wall. R Braced Wall Lines Review from 9D Requirements and location Table R Panels must begin within 12 6 of the end of wall In line, or offset no more than 4 Braced Wall Line Construction Review from 9D Meet one of 8 designs in section R Seismic category and location in structure will govern which design may be used Length of panels must comply with R Generally 48 Resisting Lateral Loads Chapter 6 Walls: Prescriptive Application Resisting Lateral Loads Chapter 6 Walls: Prescriptive Application SEISMIC DESIGN CATEGORY OR WIND SPEED Categories A and B (S s 0.35g and S ds 0.33g) or 100 mph and less 6-4
36 Lesson 6: Wall Construction Resisting Lateral Loads Chapter 6 Walls: Prescriptive Application CONDITION One story Top of two or three story First story of two story Second story of three story First story of three story Resisting Lateral Loads Chapter 6 Walls: Prescriptive Application TYPE OF BRACE Methods 1, 2, 3, 4, 5, 6, 7 or 8 Methods 1, 2, 3, 4, 5, 6, 7 or 8 Methods 2, 3, 4, 5, 6, 7 or 8 8 Methods for Braced Panels 1. 1 x 4 diagonal brace 2. Wood boards, diagonally 3. Wood structural panels 4. Fiberboard sheathing panels 5. Gypsum, sheathing or wallboard 6. Particle board sheathing panels 7. Portland cement plaster 8. Hardboard panel siding Resisting Lateral Loads Chapter 6 Walls: Prescriptive Application AMOUNT OF BRACING Located in accordance with Section R and at least every 25 feet on center but not less than 16% of braced wall line for Methods 2 through 8. Located in accordance with Section R and at least every 25 feet on center but not less than 16% of braced wall line for Method 3 or 25% of braced wall line for Methods 2, 4, 5, 6, 7 or 8. Located in accordance with Section R and at least every 25 feet on center but not less than 25% of braced wall line for Method 3 or 35% of braced wall line for Methods 2, 4, 5, 6, 7 or 8. R Appendix pg. 11 Continuous Structural Panel Sheathing Another approach to bracing wall lines Use structural panels Entire wall must be sheathed Length (width) of braced panel may be REDUCED to as little as 24 R Continuous Structural Panel Sheathing The requirement: (there is only one paragraph) METHOD 3 bracing Braced PANEL LENGTHS (width) per Table R Corners in accordance with Fig. R Table R (% of wall length) may be reduced based on wall openings 48 OK Normal Bracing Method Normal PANEL WIDTH is Doesn t Count 24 Not Even Close Panels are required near each end, and in Seismic Category C the wall could require 16% to 60% braced panels 6-5
37 Lesson 6: Wall Construction R Continuous Structural Panel Sheathing braced wall panel lengths (width) shall be in accordance with TABLE R Length Requirements for Braced Wall Panels in a Continuously Sheathed Walla, b, c MINIMUM LENGTH OF BRACED WALL PANEL (inches) MAXIMUM OPENING HEIGHT NEXT TO THE 8-foot wall 9-foot wall 10-foot wall BRACED WALL PANEL (% of wall height) R Continuous Structural Panel Sheathing If this is an 8 high wall 48 OK 32 OK 24 OK MINIMUM LENGTH OF BRACED WALL PANEL (inches) 8 wall 9 wall 10 wall MAXIMUM OPENING HEIGHT NEXT TO THE BRACED WALL PANEL (% of wall height) R Continuous Structural Panel Sheathing Reduction in the AMOUNT (total length) of braced panels is allowed Based on Table R , Method 3 Multiple the required % x 0.9 Next to 85% height opening Multiple the required % x 0.8 Next to 67% height opening Table (Normal Bracing) AMOUNT OF BRACING Located in accordance with Section R and at least every 25 feet on center but not less than 16% of braced wall line for Methods 2 through 8. Located in accordance with Section R and at least every 25 feet on center but not less than 16% of braced wall line for Method 3 or 25% of braced wall line for Methods 2, 4, 5, 6, 7 or 8. Located in accordance with Section R and at least every 25 feet on center but not less than 25% of braced wall line for Method 3 or 35% of braced wall line for Methods 2, 4, 5, 6, 7 or 8. This was a couple slides back! R Continuous Structural Panel Sheathing Reductions allowed for CONTINUOUS SHEATHING Glens Falls: Max opening Max opening Full height SDC C is 67% of wall height (window) is 85% of wall height (door) (100%) opening One story or top story Normal 16%, Multiple by.8 = 12.8% Normal 16%, Multiple by.9 = 14.4% 16% No reduction Example: Appendix pg. 12 Length of braced wall line is 50'. This is a one story house. Wall height is 8'. This wall contains a door, but no full height opening. 6-6
38 Lesson 6: Wall Construction Example: Step 1 Example: Step 2 Determine Required % of Bracing Table Max. opening height One story house When maximum opening in braced wall line is a door - 85% of wall height Normally 16%, reduced by a factor of.9 = 14.4% Evaluate each panel to determine if the panel qualifies Based on TABLE Example: Step 2 Example: Step 2 Evaluate each panel to determine if the panel qualifies Based on TABLE Evaluate each panel to determine if the panel qualifies Based on TABLE PANEL 1: Required to be 32 - Qualifies PANEL 2: Required to be 32 because of the DOOR opening- Does NOT Qualify Example: Step 2 Example: Step 2 Evaluate each panel to determine if the panel qualifies Based on TABLE PANEL 3: Required to be 24 - Qualifies Evaluate each panel to determine if the panel qualifies Based on TABLE PANEL 4: Required to be 24 -Qualifies 6-7
39 Lesson 6: Wall Construction Example: Step 3 Example: Step 4 NEEDED 50 wall requires 14.4% braced = 7.2 From Table , Ensure panels are spaced no more than 25' on center and are located near each end of the braced wall line As shown = = 6 10 Required is 14.4% - This example FAILS Alternate Bracing Methods Alternate braced wall panels Allowed as a replacement for a 4 panel Table R Minimum Widths and Tie-down Forces of Alternate Braced Wall Panels HEIGHT OF BRACED WALL PANEL SEISMIC Sheathed Width CATEGORY AND TIE-DOWN 8 ft. 9 ft. 10 ft. 11 ft. 12 ft. WINDSPEED FOE (lb) 2-4" 2-8" 2-8" 3-2" 3-6" R , SDC A, B, and C Item Windspeed < 110 R , mph Item SDC D 0, D 1 and D 2 Windspeed < 110 mph Sheathed Width R , 2-8" 2-8" 2-8" Note a Note a Item R , Item Alternate Bracing Methods Alternate braced wall panel adjacent to a door or window opening Portal Frame system R604 Wood structural panels OTHER MATERIALS Must have identification and grade stamp Meet spans shown in Table R602.3(3) Attached to framing as indicated in Table R602.3(1) Chapter 6 also covers the requirements for constructing walls using other materials such as Steel Masonry Insulated concrete form If the plans indicate use of one of these other materials follow the requirements found in the appropriate section 6-8
40 Lesson 7: Wall Covering Wall coverings NEW YORK STATE LESSON 7 CHAPTER 7 WALL COVERINGS All wall coverings Interior Exterior Shall comply with this chapter NEW YORK STATE R702 Interior Coverings NEW YORK STATE R702.3 Gypsum Board (Interior) Shall be installed to tables R702.1(1) Thickness of Plaster R702.1(2) Gypsum Plaster Proportions R702.1(3) Portland Cement Plaster R Min. Thickness of Gypsum Board Because it is the most widely used material we will concentrate on Gypsum Board All gypsum Board materials and accessories must comply with the ASTM requirements shown in section R NEW YORK STATE R Wood Framing R Application NEW YORK STATE Framing supporting gypsum board shall be Minimum 2 thick (nominal) in the least dimension OR Minimum 1 furring strip installed over solid backing or studs 24 o.c. maximum Gypsum board must be installed to tables R Interior R602.3(1) Exterior to assure proper size, spacing, fastening and orientation to supporting structures 7-1
41 Lesson 7: Wall Covering NEW YORK STATE TABLE R APPLICATION OF GYPSUM BOARD R Fastening NEW YORK STATE When using screws to attach gypsum to wood framing screws must be Type W Type S Must penetrate the framing member a minimum of 5/8 NEW YORK STATE R703 Exterior Coverings NEW YORK STATE Water Resistive Barriers Exterior wall must protect the structure with a weather resistant envelope Includes flashing g( (R703.8) Water resistant barrier Means of draining to the exterior Condensation protection (Energy chapter) Use Table R703.4 for exterior finishes and fastening "water-resistive barrier" replaces the term weather-resistant resistant barrier NEW YORK STATE WATER-RESISTIVE BARRIER (WRB) A material behind an exterior wall covering that is intended to resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly. NEW YORK STATE Water Resistive Barriers Defined as minimum water vapor permeance of 300ng/Pa s m² Examples: #15 Felt Paper (or better) Grade D Building Paper Tested House Wraps Insulating Sheathing???? 7-2
42 Lesson 7: Wall Covering NEW YORK STATE Types of Flexible Sheet Barriers Other Types of WRBs NEW YORK STATE Asphalt saturated organic felt Asphalt saturated kraft paper Polymer sheets (polyolefin fibers or extruded polyethylene films) Board products (i.e., foam core board) Liquid or trowel applied products NEW YORK STATE Water Resistive Barriers NEW YORK STATE Water Resistive Barriers Water resistive barriers, combined with proper flashing, are intended to block liquid water from entering wall assembly. Objective is to channel liquid water and drain to the exterior. Wall assemblies do not have to be designed to drain accumulated water to the exterior of the veneer if: They have been designed to resist winddriven rain. Have been tested and found to comply with ASTM E311 under prescribed conditions. Masonry & concrete walls are also exempt. Flashing NEW YORK STATE R703.4 Attachment NEW YORK STATE EXPANDED REQUIREMENT Flashing shall be installed in shingle fashion Flashing shall be installed at exterior window and door openings Shall extend to the surface of exterior wall finishes or to the water-resistive barrier for subsequent drainage from the exterior wall envelope Exterior wall coverings must be attached as shown in table R703.4 OR With Aluminum Stainless steel Zinc-coated Or other corrosive resistive fasteners 7-3
43 Lesson 7: Wall Covering TABLE R703.4 SIDING ATTACHMENT NEW YORK STATE Summary NEW YORK STATE Interior and Exterior sheathing must be installed as shown in Chapter 7 Regulates Thickness of material Spacing of supporting structure Fasteners to be used 7-4
44 Lesson 8: Roof Ceiling Construction LESSON 8 CHAPTER 8 ROOF CEILING CONSTRUCTION What are you looking for in Chapter 8? Chapter 8 has both prescriptive and performance requirements that deal with Roof-Ceiling systems It contains tables, figures and requirements to meet specific Reference Standards It includes certification requirements for numerous types of materials, assemblies, and systems Chapter 8 Consists of 8 sections R801 General R802 Wood Roof Framing R803 Roof Sheathing R804 Steel Roof Framing R805 Ceiling Finishes R806 Roof Ventilation R807 Attic Access R808 Insulation Clearance R802.3 Framing Details Rafters Fastened to Ridge Board Ridge Board minimum thickness 1 or To each other with a gusset plate as a tie R802.3 Framing Details R Connections Valley and Hip Rafters Supported at the ridge by a brace that transfers the load to a bearing partition Ceiling joists and rafters must be nailed together according to Table R (9) Roof pitch < 3/12 Structural members supporting rafters and joists To be designed as beams Ceiling joist shall be nailed to the top plate in accordance with Table 602.3(1) 8-1
45 Lesson 8: Roof Ceiling Construction R Connections Ceiling joists parallel to rafters must be: continuous (one piece) or secured over partitions and at rafters to provide a building tie R Connections Ceiling joists not parallel to rafters must have: 1 x 4 Collar ties for wind upift installed in upper third, not more than 4 O.C. 2 x 4 Rafter ties at bottom of opposing rafters R Ceiling Joists Minimum lap 3 or butted over bearing partitions or beams and toe nailed Ceiling joists used to resist rafter thrust must be fastened according to Table R602.3.(1) R802.4 Ceiling Joist Spans Allowable Spans for Common Species are found on tables R802.4(1) 10 psf LIVE load Attic, no storage R802.4(2) 20 psf LIVE load Attic, limited storage AF&PA has Span Tables for other grades, species and loading conditions R802.5 Rafter Spans Allowable rafter spans for common species are found in Tables R (1) through R (8) For other grades, species, or loading conditions use the AF&PA Span Tables and ASCE 7 R Purlins Purlins are used to reduce the span of rafters Purlins must be Same size as the rafters Continuous Supported by 2 x 4 braces Set on bearing wall Minimum 45 degrees Maximum spacing 4 8 maximum length PERLIN 2x4 BRACE 8-2
46 Lesson 8: Roof Ceiling Construction R802.6 Bearing R802.7 Cutting and Notching Minimum bearing of rafters and ceiling joists must be Not less than 1½ on wood or steel Not less than 3 on masonry or concrete Notches shall not Exceed one-sixth of the depth of the member Be longer than one-third of the depth of the member Be located in the middle one-third of the span Exceed one-fourth the depth of member if notched at the end of members The tension side of members shall not be notched except at the ends R802.7 Cutting and Notching Holes Diameters shall not exceed one-third the depth of member Shall not be closer than 2 from the top or bottom of member Shall not be closer than 2 to any other hole in the member, or to any notch in member R802.7 Cutting and Notching Engineered Wood Products Cuts, notches and holes are prohibited except where Permitted by the manufacturer's Considered in the design by a registered design professional Translation: Engineered wood products can only be altered within the guidelines of the manufacturers specifications R802.8 Lateral support Rafters and ceiling joists having a depth-to-thickness ratio exceeding 5 to 1 (nominal dimension) shall be provided with lateral support at points of bearing to prevent rotation Translation Members larger than a 2x10 must be blocked at the bearing points R Bridging Rafters and ceiling joists having a depth-tothickness ratio exceeding 6 to1 (nominal) shall be laterally supported by Solid blocking Diagonal bridging (wood or metal) Continuous 1 x3 wood strip Fastened across rafters or ceiling joists at no more than 8 intervals Translation Members larger than 2x12 must have bridging every 8 feet 8-3
47 Lesson 8: Roof Ceiling Construction R802.9 Framing of Openings Openings in roof framing must be framed using headers and trimmer joists The requirements are very similar to those we covered for floors R Wood Trusses Truss Design Drawings Provided with the trusses Provided to the local CEO prior to installation Must include minimum information specified in section R R Truss Design Wood Trusses must be designed using accepted engineering practice Truss design drawings shall be prepared by a design professional (and bear a seal and signature) The design and construction of all metal plate connected trusses shall comply with ANSI/TPI 1 E X A M P L E Example Truss lay-out Identifies truss location R Truss Bracing Trusses must be braced to prevent rotation and to provide lateral stability as indicated in: Construction Documents Construction Documents Truss Design Drawings Or BCSI
48 Lesson 8: Roof Ceiling Construction R Roof Tie Down Subject to UPLIFT pressures of 20 lbs or greater determined as follows: Table R301.2(2) Components and Cladding 100 SF and Zone 1 Table R301.2(3) Height and Exposure Category FIGURE R301.2(8) Component and Cladding Pressure Zones Simplified wind design Not used or needed for Main Wind-force Resisting System NY is Prescriptive for most construction Applies to Rafters and Trusses TABLE R301.2(2) Component and Cladding Loads Mean roof height of 30 feet in Exposure Category B TABLE R301.2(3) Height and Exposure Adjustments Effective Area ZONE shown in Fig (8) Basic Wind Speed Multiply value from Table R301.2(2) by factor from this Table Exposure B Typical, buildings and hills Exposure C Flattish, wide open Exposure D Flat water, 1 mile Roof assembly based on pitch Wind Pressure Positive or Negative Wall construction R Roof Tie Down Subject to UPLIFT pressures of 20 lbs or greater shall have connectors: Our Project Building Given: Located in a 90 MPH Wind Zone Steep Roof pitch 9/12 and 12/ uplift pressure Adjust for Roof Height (use 25 ) Adjusted uplift is less than 20 lbs, hurricane straps NOT required OR for trusses, as specified by the manufacturer 8-5
49 Lesson 8: Roof Ceiling Construction R Truss to Wall Connection Install per the Manufacturer s specifications Connection to resist uplift force as specified in the truss design drawings 3) Provide mechanical connections (by others) of truss to bearing plate capable of withstanding 417 lb. uplift at joint 1 and 514 lb. uplift at joint 7. Summary We have now covered Lessons 5 Floors 6 Walls 7 Wall Coverings 7 Wall Coverings 8 Roof Framing We have also looked at some of the typical areas to check during a framing inspection Note 3. Click to enlarge! 8-6
50 Lesson 9: Roof Assemblies Roof Assemblies LESSON 9 Chapter 9 Roof Assemblies 7 Sections R901 General R902 Roof Classification R903 Weather Protection R904 Materials R905 Requirements for Roof Coverings R906 Roof Insulation R907 Reroofing R905 Sub-Sections Each material has a section R905.2 Asphalt shingles R905.3 Clay/Concrete tile R905.4 Metal roof shingles R Mineral surface roll roofing R905.6 Slate shingles R905.7 Wood shingles R905.8 Wood shakes R905.2 Asphalt Shingles Shingles composed of organic felt or glass felt with granular mineral coating 3-tab Architectural Interlocking shingles R905.2 Asphalt Shingle. The installation of asphalt shingles shall comply with this section. ETC. through R905.2 Asphalt Shingles R905.2 Asphalt Shingles R Sheathing Requirements R Slope Shingles shall be fastened to solidly sheathed decks Roof Slope limits the use and installation of roof materials R803 Provides the details for sheathing Lumber sheathing Spaced lumber sheathing Structural panels R Sheathing Fasteners Asphalt shingles Slopes 2:12 or greater Underlayment Slopes 2:12 to 4:12 (Double layer) 9-1
51 Lesson 9: Roof Assemblies R905.2 Asphalt Shingles R905.2 Asphalt Shingles R Fasteners R Attachment Galvanized Steel, Stainless Steel, Aluminum, or Copper nails Min.12 gage shank 3/8 diameter head Penetrate into sheathing ¾ minimum ASTM F 1667 Asphalt shingles shall be installed to manufacturers specs... Minimum of four fasteners per strip shingle Minimum of two fasteners per individual shingle Special methods required for wind speeds over 110 mph (Modified ASTM classification) Manufacturer s Specifications R905.2 Asphalt Shingles R Underlayment Roof Slopes 2:12 to 4:12 underlayment shall be two layers 19 starter strip at eave Over-lap starter with a 36 strip Over-lap successive strips 19 Fastened sufficient to hold in place Roof slopes 4:12 and greater shall be one layer Full width sheet starting at eave Successive layers overlapped 2 Low Slope Underlayment R905.2 Asphalt Shingles R Ice Protection Areas where there has been a history of ice forming along the eaves Table R301.2(1) criteria designates Ice Barrier shall be provided This includes all of New York State 9-2
52 Lesson 9: Roof Assemblies Ice Shield Ice Barrier Installation 24 minimum inside building line Ice Dam Proper Installation R905.2 Asphalt Shingles R Valleys Open Valley Flashing Shall comply with Table R Valley linings shall be installed to manufacturer s specifications before shingles are installed This section allows open or closed valley installations as follows 9-3
53 Open Valley Flashing Lesson 9: Roof Assemblies Closed Valley Flashing Shall comply with ASTM D 6380 Class S Type III, Class M Type II, or ASTM D 3909 If exposed corrosion-resistant metal materials are used as valley linings, they are regulated by this table R905.2 Asphalt Shingles R905.2 Asphalt Shingles R Crickets and Saddles Required on the ridge side of all penetrations over 30 wide R Sidewall Flashing Flashing at vertical side walls shall use the step flashing method R905.2 Asphalt Shingles Section 907 Reroofing R Other Flashing Soil stacks Vent pipes Chimney re-covering or replacing of an existing roof covering shall comply with the requirements of Appendix J Section AJ
54 Lesson 9: Roof Assemblies Appendix J Section AJ Recover vs. Replace New roof coverings shall not be installed over existing roof coverings if 1. Existing roof or roof covering is Water Soaked Deteriorated Has inadequate base 2. Existing roof covering is Wood shake, slate, clay, cement or asbestos cement tile 3. Existing roof has two or more layers of Any roof covering material 4. Asphalt shingles in severe hail exposure area AJ Reinstallation of Materials Reinstallation of Slate, Clay or Cement Tile shall be permitted except for Broken, cracked, damaged materials Existing Flashing if rusted, damaged, or deteriorated Aggregate surface material shall not be reinstalled Summary Roofing must provide weather-resistant protection for the structure This chapter recognizes 14 different types of roofing materials Proper installation methods outlined in this chapter and in the manufacturer s specifications must be followed Reroofing is also regulated by this chapter 9-5
55 Lesson 10: Chimneys and Fireplaces OF NEW YORK STATE OF NEW YORK Chapter 10 Chimneys and Fireplaces Chapter 10 Chimneys and Fireplaces R1001 Masonry Fireplaces R1002 Masonry Heaters R1003 Masonry Chimneys R1004 Factory-Built Fireplaces R1005 Factory Built Chimneys R1006 Exterior Air Supply Chapter 10 OF NEW YORK Regulates Chimneys and Fireplaces Masonry fireplaces, chimneys and heaters Prescriptive Requirements Factory built fireplaces and chimneys Require Listing and Labeling But that s not all, it also contains Requirements for exterior air supply OF NEW YORK R1001 Masonry Fireplaces Constructed to requirements of chapters 3 and 4 Footing Solid masonry or concrete Minimum 12 thick Minimum 6 wider than exterior of chimney Located below frost line Seismically reinforced OF NEW YORK OF NEW YORK 10-1
56 Lesson 10: Chimneys and Fireplaces OF NEW YORK R1002 Masonry Heaters R Installation Masonry heaters shall be installed to one of the following: ASTM E 1602, or Listed and Label, follow manufacturer s instructions OF NEW YORK R1003 Masonry Chimneys R Footings and Foundations Solid masonry or concrete Minimum 12 thick Minimum 6 wider than exterior of chimney Located below frost line OF NEW YORK R1003. Corbeling Must meet the requirements of this section OF NEW YORK R Termination Height of chimney 2 higher than peak or highest portion of roof within 10 of chimney 3 higher than roof deck at the high side of the penetration point OF NEW YORK R Chimney Clearances Chimneys located in building or in exterior walls must have 2 clearance to combustibles Those located completely outside the building must have a 1 clearance to combustibles OF NEW YORK R Chimney Crickets Required on all chimneys over 30 in width Crickets to be sized in accordance with table R
57 Lesson 10: Chimneys and Fireplaces OF NEW YORK R1004 Factory-Built Fireplaces R General Shall be listed and labeled Installed in accordance with the listing and manufacturer s specifications Tested according to UL 127 OF NEW YORK R Unvented Gas Log heaters Shall not be installed in a Factory-built Fireplace Unless the fireplace was Tested Listed Labeled In accordance with to UL 127 OF NEW YORK R1005 Factory Built Chimneys R LISTING Shall be listed and labeled Shall be installed according to manufacturers instructions R SOLID FUEL APPLIANCES Factory built chimneys shall comply with the Type HT requirements of UL 103 Marked "Type HT and "Residential Type and Building Heating Appliance Chimney." OF NEW YORK R1006 Exterior Air Supply R Exterior Air Shall be equipped with an exterior air supply R Factory-built Fireplaces R R Masonry Fireplaces R Exterior Air Intake R Clearance R Passageway R Outlet Fireplace The house under review has a directvent fireplace OF NEW YORK All factory built fireplaces must be installed to the manufacturer s specifications You will need the installation manual to do the rough-in inspection, be sure to check all clearances At the final inspection you will have to inspect for operation and proper clearances to combustible finishes Summary OF NEW YORK Chapter 10 regulates Factory built chimneys and fireplaces Masonry built chimneys and fireplaces Masonry units comply with Table R and Figure R Factory units comply with Manufacturer s listing, labeling and installation requirements and this chapter 10-3
58 Lesson11: Energy Efficiency Lesson 11 Energy Conservation Residential Compliance Minimum prescriptive requirements for the design and construction of energy-efficient buildings and systems Section N1101 General (MANDATORY) MANDATORY Provisions: Section N1101, General rules and product identification Specifically listed items in N1102 Building Thermal Envelope Access hatches and doors Common, party, and fire walls Air leakage Vapor retarders Section N1103 Systems (Mandatory) Chapter 11 Energy Efficiency Section N1101 General Same concepts as in the Energy Code Scope = Residential Code buildings Exceptions: Non-conditioned spaces Solely renewable energy sources Exempt Buildings Low energy buildings Historic buildings Section N1101 General Same concept as in the Energy Code N Additions, Alterations, Renovations and Repairs Any new work to conform to new construction standards The unaltered portions may remain An Addition may show compliance alone or as a single building Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Section N1101 General Same concept as in the Energy Code N Compliance (options) ECCCNY (Chapter 4) This Chapter (same basic concept) Based on CLIMATE ZONES Chapter 11 Energy Efficiency TABLE N Climate Zones by County Zone 4 Zone 5 Zone 6 Bronx Kings Nassau New York Queens Albany Cayuga Chautauqua Chemung Columbia Ontario Orange Orleans Oswego Putnam Allegany Broome Cattaraugus Chenango Clinton Montgomery Oneida Otsego St. Lawrence Schoharie Richmond Suffolk Westchester Cortland Dutchess Erie Genessee Greene Livingston Monroe Niagara Onondaga Rensselaer Rockland Saratoga Schenectady Seneca Tioga Washington Wayne Yates Delaware Essex Franklin Fulton Hamilton Herkimer Jefferson Lewis Madison Schuyler Steuben Sullivan Tompkins Ulster Warren Wyoming Chapter 11 Energy Efficiency 11-1
59 Lesson11: Energy Efficiency Section N1101 General Same concepts as in the Energy Code N Compliance Materials Software (US DOE) REScheck COMcheck REM/Rate and REM/Design Other home energy rating (HERS) software Energy modeling based on ASHRAE 90.1 REScheck Software Building Thermal Envelope Meet Table N Crawl Glazed Wood Mass Basement c Slab d Space c Climate Fenestration Skylight b Fenestration Ceiling Frame Wall Wall Floor Wall R-value Wall Zone U-factor U-factor SHGC R-value R-value R-value R-value R-value &Depth R-value NR /10 g 19 10/13 c 10, 2 ft d 10/13 c NR NR or 13+5 f 13/17 g 30 e 10/13 c 10, 2 ft d 10/13 c 20 or 13+5 f 15/19 g 30 e 10/13 c 10, 4 ft d 10/13 c Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Building Thermal Envelope Approaches R-value Computation (using Tables) Use all identified R-values in the assembly DON T include other components U-factor Alternative Use value from all components of the assembly Table N provides equivalents Total UA Alternative SUM of U-factor times assembly area Building Thermal Envelope N Ceilings with attic spaces Values in table N for ceilings May be reduced If insulation is not compressed at the exterior wall R-38 can be reduced to R-30 R-49 can be reduced to R-38 Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Examples Raised Heel Construction N Ceilings with attic space Building Thermal Envelope R806 Roof Ventilation Reductions allowed: R38 to R30 R49 to R38 Uncompressed Insulation Raised rafter (engineered) Insulation : Cathedral Ceilings Vent Spacers No Compression or gaps in Insulation Raised heel truss Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency 11-2
60 Lesson11: Energy Efficiency Building Envelope N Recessed Lighting Fixtures Recessed Lighting Fixtures Sealed to limit air leakage Must be IC rated Gasketed or Caulked Building Envelope N Moisture Control Vapor Retarder Climate zones 5 and 6 Installed on the interior side of wall Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Site Verification Some items must be verified by inspections Section N1101 General Same concepts as in the Energy Code N Building Thermal Envelope Insulation Insulation R Values and Installation Quality Fenestration U Values, % of glazing Air Sealing Vapor Retarders and Ventilation Equipment installation Identification of Materials and Installation R-value applied to material Installers certification Markers for blown or sprayed insulation R-value observable for inspection Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Blown in Insulation Same concepts as in the Energy Code Provide markers every 300 sq. ft. to verify depth Section N1101 General Same concepts as in the Energy Code N Insulation on exterior of foundation Protection to extend to 6 below grade Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency 11-3
61 Lesson11: Energy Efficiency Section N1101 General Same concepts as in the Energy Code N Certificate posted On or near electrical panel Builder or Designer R-values and U-factors Insulation Basement Wall Must be protected above grade Must extend below grade to depth indicated in Example Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Slab on Grade Insulation N Examples Slab on Grade Insulation Example 45 o Bevel OK a a + b = 24 or 48 depending on HDD b Insulate either inside or outside a Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Building Envelope N Air Leakage (MANDATORY) Building thermal envelope. The building thermal envelope shall be durably sealed to limit infiltration. Building Envelope N Air Leakage (MANDATORY) Air sealing and insulation. shall be demonstrated to comply with one of the following options N Testing Option Blower Door N Visual Inspection Option Thermal Bypass Inspection Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency 11-4
62 Lesson11: Energy Efficiency Air Leakage Testing Option Blower Door testing ACH 50 better than 7 Chapter 11 Energy Efficiency Air Leakage Visual Inspection Option Table AIR BARRIER and INSULATION INSPECTION Component Criteria COMPONENT CRITERIA Air barrier and thermal barrier (MORE) Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. The Code official may require an independent inspection Chapter 11 Energy Efficiency Systems N Controls At least one thermostat for each system Programmable thermostat for each dwelling unit Systems N Ducts All ducts located in UNCONDITIONED SPACE must be insulated Supply ducts in attics minimum R- 8 All other ducts minimum R- 6 Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency Systems N Duct Sealing ALL ducts, air handlers, filter boxes and building cavities used as ducts shall be sealed. Systems Miscellaneous details Lighting equipment. A Minimum of 50 percent high-efficacy lamps. Ducts OUTSIDE of the Building Envelope must be VERIFIED by one of the following: Post-construction test Rough-in test Chapter 11 Energy Efficiency Chapter 11 Energy Efficiency 11-5
63 Lesson 12: Systems and the Final Inspection The Residential Code of New York State Lesson 12 Wrapping it up Part 1: Checking the systems Part 2: The Final Inspection Part 1 The Systems Mechanical Chapters Fuel gas Chapters 24 Plumbing Chapters Electrical Chapters Most of these items were covered in Course 9D so let s review the basics Mechanical Mechanical Heating and Cooling Systems Boilers and Water Heaters Duct Systems Chimney and Vent Systems Exhaust Systems Dryers Bathrooms R303.8 Required Heating Every Dwelling Unit in New York State o (Winter Design Temperature for entire state is below 60 F) Must have a heating system capable of maintaining a room temperature of at least o 68 F at a point 3 above the floor and 2 from exterior walls in all habitable spaces Exception: Owner-occupied one-family Minimum Requirements M All equipment must have a permanently affixed label which provides basic information about the unit Equipment must only be installed and operated consistent t with it s listing M All equipment must be installed to allow sufficient space for clearances and clear access for service M Heating and Cooling equipment must be sized in accordance with ACCA Manual J 12-1
64 Lesson 12: Systems and the Final Inspection Fuel Gas Review Chapter 24 regulates appliances that utilize LP and Natural Gas All equipment must be installed to the manufacturer s specifications Gas piping must be sized and installed to provide sufficient gas supply to all appliances in the system All equipment must be properly vented Plumbing Every dwelling unit must be provided with a: Water closet Lavatory Bathtub or Shower Kitchen sink Exception: Owner-occupied one-family Plumbing All plumbing systems must be connected to an approved water supply Every kitchen sink, lavatory, bathtub, shower, laundry tub and washing machine hook up must have hot and cold water All plumbing systems must be connected to an approved sewage disposal system Electrical Each dwelling unit must have it s own meter E3502 Service must be sized based on the loads of the equipment in the dwelling Minimum service size is 100 amps E3507 All electric circuits must be properly grounded Electrical Service Disconnect Required Disconnects must be provided on all circuits All circuits must be labeled Outlets E Convenience outlets must be provided: On any wall area 2 or wider Within 6 of any entrance to a room A maximum of 12 apart around the perimeter of all rooms 12-2
65 Lesson 12: Systems and the Final Inspection Electrical Electrical Section 3802: Ground-fault and Arc-fault Circuitinterrupter Protection E Kitchens must have a minimum of 2-20 amp circuits E Any counter space 12 or wider must be served by an outlet Outlets along counter tops must be spaced a maximum of 4 apart Ground fault protection locations: Bathroom Receptacles Garage and accessory buildings Outdoor receptacles Crawl space Laundry, utility, and bar sink receptacles Unfinished basements Kitchen receptacles Laundry, utility, and bar sink receptacles Boat house and boat hoist receptacles Electrically heated floors Electrical Arc-fault circuit-interrupter protection. ALL branch CIUITS that supply 120- volt, single-phase, 15- and 20-ampere outlets Family Rooms, Dining Rooms, Living Rooms, Parlors, Libraries, Dens, Bedrooms, Sunrooms, Recreations Rooms, Closets, Hallways and Similar Electrical Tamper-resistant receptacles General purpose receptacle distribution Small appliance receptacles Countertop receptacles Appliance receptacle outlets Bathroom Outdoor outlets Laundry areas Basements and garages HVAC outlet Conclusion This course has taken us from, learning the code, to doing a plan review, to performing the required inspections Although this course did not cover every topic in the Residential Code, it has given you a basic understanding of how to use the code Remember if you need any assistance in the future you can call your regional office or the Albany office Now the best part of the course 12-3
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
Patio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
Uncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
Detached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Sample Drawing Package for One and Two Family Dwelling Applications
Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Development Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
Pre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
How To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
MICHIGAN RESIDENTIAL CODE 2003
MICHIGAN RESIDENTIAL CODE 2003 APPLICABILITY: A permit is required to construct, enlarge, alter, repair, move, demolish or change the occupancy of any structure. EXCEPTION: One story detached accessory
STANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
Georgia Association of Home Inspectors
Georgia Association of Home Inspectors Standards of Practice for Framing Inspections OVERVIEW The purpose of the GAHI (Georgia Association of Home Inspectors) Standards of Practice for Framing Inspections
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
INFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 (June 26, 1998, Revised March 26, 2009) City Planning & Development - Development Services City of Kansas
Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County
Building Permit Application Packet The purpose of Building Codes is to establish the minimum requirements to safe guard the public health, safety and general welfare through structural strength, means
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use
If you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
Building Department John Fiedler Construction Official Ext. 211. SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev 4-3-2014
TOWNSHIP OF HILLSBOROUGH COUNTY OF SOMERSET Hillsborough Township Municipal Complex The Peter J. Biondi Building 379 South Branch Road Hillsborough, NJ 08844 P: (908) 369-4313 F: (908) 369-3954 Building
INFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 June 26, 1998 (Revised June 4, 2014) City Planning & Development - Development Services City of Kansas
Residential Plan Routing Information
Residential Plan Routing Information BUILDING INSPECTIONS 800 4th AVENUE EAST WEST FARGO, ND 58078 PHONE: 701-433-5480 The building Inspection s Department receives and issues all applications for building
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
INTERNATIONAL RESIDENTIAL CODE 2006 Third Edition
WASHINGTON STATE BUILDING CODE CHAPTER 51-51 WAC INTERNATIONAL RESIDENTIAL CODE 2006 Third Edition Washington State Building Code Council Copies of the State Building Codes and complete copies of the 2006
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines
Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines The following list of code requirements is intended to assist you in complying with the Code of Public Local Laws
REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
Page & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST
CITY OF BERKELEY DETAILED CHECKLIST This checklist will assist you in preparing plans for submittal with a building permit application. Alterations, additions and remodeling projects may not require all
Building Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
Standard Comments Checklist
November 2012 Standard Comments Checklist Scope: Prescriptive 2500 square feet, conventional light frame wood construction, single family dwelling Red Text = Specific code requirements based on design
APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
Typical Finished Basement Details
Fauquier County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements,
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
MUNICODE SERVICES LTD.
The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved
SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322)
SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322) The following information contains simplified explanations of significant changes to the 2015 Requirements for Radon
Engineered Wood Foundations
Engineered Wood Foundations Emeraldfoundations.com 1 EWF Planning and Installation manual This manual will serve as a guide to planning and installing an Emerald Foundation system. This system is comprised
COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS
COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS Permit applicants shall submit three (3) COMPLETE SETS of plans and specifications with each application for a permit. Plans and specifications
8/18/14. Introduction to. Framing. Terminology and Concepts
8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA College of Marin c/o Swinerton Management & Consulting P.O. Box 144003 835 College Avenue, Building MS-3 Kentfield, California
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Basic Requirements for Residential Plan Review _
Basic Requirements for Residential Plan Review _ Below you will find the basic requirements for your plan submittal. General: Drawn to scale Plan Size minimum: 9 x 12 Designer, Engineer, or Architect name,
Single Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)
TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers
City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.
EXISTING BUILDINGS AND STRUCTURES
EXISTING BUILDINGS AND STRUCTURES There are no margin bars shown in this chapter due to its substantial revision. SECTION AJ1 ADMINISTRATION SECTION AJ101 PURPOSE AND INTENT AJ101.1 Scope. The provisions
Typical Finished Basement Details
Fairfax County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements, details
FIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open
Add Strength and Water Resistance When Repairing Your Walls Any home repair or remodeling work you do presents an opportunity to make your home fare better in the next storm. Whether you are just replacing
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519
CALIFORNIA BUILDING CODE
CALIFORNIA BUILDING CODE NONSTRUCTURAL DESIGN REQUIREMENTS This section contains portions of the California Building Code which relate to basic minimum nonstructural design requirements for a residence.
2014 FLORIDA BUILDING CODE
MINIMUM REQUIREMENTS FOR NEW 1 & 2 FAMILY RESIDENTIAL STRUCTURES (ALL PLANS MUST BE 22 X 36 ) WIND BORNE DEBRIS AREA Is the proposed structure located in the wind borne debris area? If yes, one of the
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
The replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:
When is a Permit Required? The most common types of projects that require permits are: -New Houses or buildings -Room Additions or Expansions -Structural repairs, remodeling and alterations -Accessory
MANUFACTURED HOUSING USED AS DWELLINGS
MANUFACTURED HOUSING USED AS DWELLINGS SECTION AE101 SCOPE AE101.1 General. These provisions shall be applicable only to a manufactured home used as a single dwelling unit and shall apply to the following:
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION
RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION
Building Information Packet
Code Enforcement Department 882-9225 Building Information Packet The following information has been compiled to help you as a homeowner or contractor with the various steps and requirements for a building
2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05)
NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05) NAVAJO COUNTY GOVERNMENTAL COMPLEX P.O. BOX 668 HOLBROOK, ARIZONA
FIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
BUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh
Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years
Significant Code Changes to the 2009 International Residential Building Code
Significant Code Changes to the 2009 International Residential Building Code CHAPTER 1 SCOPE AND ADMINISTRATION R106.1.1 Information on Construction Documents Where required by the building official, all
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2009 Michigan Residential Code
CHEBOYGAN COUNTY DEPARTMENT OF BUILDING SAFETY 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 Phone: (231) 627-8813 Fax: (231) 627-8454 www.cheboygancounty.net RESIDENTIAL BUILDING CODE HANDOUT
SECTION 3 ONM & J STRUCTURAL ANALYSIS
Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION
Building Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
Typical Deck Details
Fairfax County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot deviate
Chapter 20.10 LINCOLN RESIDENTIAL BUILDING CODE
Chapter 20.10 LINCOLN RESIDENTIAL BUILDING CODE Sections: 20.10.010 Adoption of International Residential Code. 20.10.015 Section R101 Amended; Title, Scope and Purpose. 20.10.020 Section R102.1 Amended;
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...