MCB-50 User Manual and Menu Map
|
|
|
- Barbra Rice
- 9 years ago
- Views:
Transcription
1 MCB-50 User Manual and Menu Map Dudullu OSB; 1. Cadde; No: Umraniye - ISTANBUL / TURKIYE Tel : Fax : A5303 / Rev.4
2 MCB-50, is an electronic timer which has a real time clock module inside It is designed for controlling the devices which are connected to its contacts according to the time periods which are programmed by the user. Day Date gg.aa.yy Hour HH:mm:ss ESC Button SET Button ESC AUTO MANUAL SET Used Summer/Winter Time status Battery Status Selected days for the shown program while in Program Menu Relay AUTO/MANUAL status Relay on/off status UP Button DOWN ESC Button : It is used to switch between monitoring menus. In the programming mode, it is used to cancel a parameter change or to return to the previous menu. SET Button : It is used to switch between monitoring menus. When it is pressed for 3 seconds, programming mode is entered. In the programming mode, it is used to apply a parameter UP change or to enter to a menu. DOWN Buttons: In the monitoring menu, it is used to switch between programs to show their activity in a day. When the DOWN button is pressed for 3 seconds, C1 relay goes into manual mode and when the UP button is pressed for 3 seconds, C2 relay goes into manual mode. In the programming menu; it is used to browse between menus, to select parameters and to adjust values with digits. Precautions for Installation and Safe Use If below precautions are not properly observed and carried out, it may result in cases with injury or death. - Disconnect power before working on the device. - When device is connected to the network, do not remove the front panel. - Do not clean the device with solvent or similar items. Only clean with dry cloth. - Verify correct terminal connections before energizing the device. - Install the device on the electrical panel. - Contact your authorized reseller in case problems occur with your device. No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences rising out of the use of this material. - The output loads connected to the relays do not function if auxiliary supply is absent. Even if the relay status is monitored as on ( and/or ), auxiliary supply is a must for the operation. - There are two reserves in the device. Programmed data is protected by these reserves against power outages. - For long time reserve, a battery is used. If the device is continously supplied with voltage, the shelf life of this battery is 10 years,. If the device is not continously supplied with voltage and waited on the shelf, the battery life is 5 years. - Reserve battery should only be changed by the authorized service. MANUAL DE : In order to use the relay outputs manually, MCB-50 has to be in the monitoring mode. The DOWN button is used to switch the C1 relay to manual mode and the UP button is used to switch the C2 relay to manual mode. When the UP or DOWN button is pressed for 3 seconds, MANUAL indication appears on the screen. If this is done while the relay C1 or C2 is activated, that relay will be deactivated. If it is done while the relay C1 or C2 is deactivated, no switching will occur. After the relay C1 or C2 is in the manual mode; when the DOWN button is pressed again for 3 seconds, C1 relay will exit the manual mode and when the UP button is pressed again for 3 seconds, C2 relay will exit the manual mode. The relay will stay activated or deactivated according to the program flow. When both of the the relays are in manual mode, AUTO indication will dissappear from the screen. 1 2
3 NITORING MENU : SET and ESC buttons are used to switch between menus in the monitoring mode. If the device is left unattended for 60 seconds in any menu other than the real time and date, it returns to the real time and date screen. 16:12:10 18:45:52 Real Time and Date Menu PO1-C1 05:44:00 Program Activity Time Menu C2-SHOT 00 Operation Count for C2 Relay C1-00 Activation Time for C1 Relay(Hours) C2-00 Activation Time for C2 Relay(Hours) C1-SHOT 00 Operation Count for C1 Relay Program activity time menu shows the programs, which are stored on the device, in order according to program activity time. The active or finished programs can be shown with UP or DOWN buttons. The programs with a sign next to them are the programs which are still active. MCB 50 Menu Settings If the SAVE option doesn t get accepted when returning to the monitoring menu, the changes which are made in the MCB-50 menus will be discarded. This isn t the case for menu. The changes which are done in menu are applied immediately. When none of the keys are pressed in the programming menu, the device returns to monitoring menu and any changes which were made will be discarded. Refer to the menu map when configuring the MCB-50 menus. Program Menu: There are 32 programs available to program between P01 and P32. The available settings for programs are relay selection, activation time, activation day, deactivation time, time conflict query and save. In addition to these, an appointed program has two additional settings as EDIT and DELETE. If EDIT is selected for an appointed program, the existing settings of that program is shown and can be reconfigured. If DELETE is selected for an appointed program, that program will be deleted permanently. Output Selection ( PXX-OUT ): MCB-50 has 2 relay outputs as C1 and C2. The user must choose between C1 and C2 as the relay output which he want to control. Activation Time Setting ( PXX-ON ): The user can use time parometer for the application Time Parameter ( ): This parameter is the adjustment of the relay according to the real time clock. If this parameter is selected, the user can enter an activation time between 00:00:00 (HH:mm:ss) and 23:59:
4 Selection of Activation Days: The day/days in which the program will be activated is adjusted in this menu. If ALL DAYS YES is selected, the program will be activated for all days of the week. If NO is selected, the user will be asked to select YES or NO for the all of the days starting from Monday in which the program will be active. There are numbers 1 to 7 on the top section of the screen.these numbers stand for the days of the week. 1 indicates Monday. These numbers also help to indicate the days in which a program will be active without entering that appointed programs menu. Deactivation Time Setting ( PXX-OFF ): The user can use time parameter for the application. This parameter is the same as in the relay activation setting The deactivation time shouldn t be earlier than the activation setting. For the cases other than this one in which the deactivation time is set earlier than the activation time, the deactivation time is set for the next day. Time Conflict Query: The device checks for any time conflicts between the existing programs and the newly entered program. If there is a time conflict, it warns the user with the CROSS PXX warning. If there isn t a time conflict, PROGRAM VALID is shown on the screen. These warnings will be shown for 3 seconds. If a button is pressed before 3 seconds run out while a warning is displayed, the save menu is entered. Save: In this menu, the user is asked to approve the changed program or not. If the program is not confirmed by the user, it stays unchanged. If the program is confirmed by the user, the changes are kept on the memory but are not in effect. When the SAVE query is confirmed by the user while returning to the monitoring menu, the changes are saved to the memory. See application example 1 and 2 Merge Function: The merge function does a logical AND operation. In the common timeframe of the merged programs, the corresponding relay becomes active. This function can be used if at least two programs are assigned for the same relay output. There are 2 sub-menus as AND-1 and AND-2. There is a DISABL parameter in these menus. When the user selects at least 2 programs, FINISH parameter becomes accessible in this menu instead of this parameter. The user browses between the parameters with UP or DOWN buttons and selects the programs which he wants to merge with SET button. According to the selection of the output of the first selected program, the programs for the other ouput are excluded from the selectable programs 5 for the users convenience to easily select the programs with the same output. To finish the selection, FINISH parameter has to be selected. After this process, AND-X sub-menu will be set and shown as occupied. To disable the merge function, the user must select the DISABL parameter. After this process, AND-X sub-menu will be set and shown as unoccupied. When the SAVE query is confirmed by the user while returning to the monitoring menu, the changes are saved to the memory. Relay Time Menu: The operation counts and activation times of the C1 and C2 relays are reset in this menu. The user can reset any of the parameter/parameters of the C1 relay. There are 4 sub-menus as C1-, C1- SHOT, C2- and C2-. When the SAVE query is confirmed by the user while returning to the monitoring menu, the changes are saved to the memory. Settings Observation Menu: The user can observe the sub-menu settings with 3 second intervals in this menu. The activation/deactivation time settings, merge function settings, holiday lock settings, summer/winter time setting, and the parameter to which the exit from the manual mode is set can be displayed. UP, DOWN and ESC buttons enables the interval between screens to extend. The SET button provides a faster browsing between the sub-menus. DE DE PO1-C1 P31-C1 AND-1 AND-2 XXXX XXXX XXXX XXXX RECOVRY XXXX DAYLIGH XXXX HOLDY-X XXXX xxxx is a symbolic representation. The set parameters are shown here. 6
5 Regional Settings Menu: Language and daylight saving time settings can be done in this menu. The changes which are made in this menu are saved to the memory when the SAVE query is confirmed by the user while returning to the monitoring menu. Language Menu: There are English and Turkish parameters. The user enters the language menu with SET button, chooses a language with UP or DOWN buttons and confirms this language with the SET button. If Turkish is selected, the change is applied immediately. But if the SAVE query isn t confimed by the user while returning to the monitoring menu, the language doesn t change. Daylight Savings Time (DST) Menu: DST usage is set in this menu. There are 4 parameters. Europe Parameter: According to the European DST settings; the DST starts when the local time is about to reach 03:00:00 and the clocks are turned 1 hour forward to 04:00:00 on the last Sunday of March. The DST ends when the local time is about to reach 02:00:00 and the clocks are turned 1 hour backward to 01:00:00 on the last Sunday of October. USA Parameter: According to the USA DST settings; the DST starts when the local time is about to reach 02:00:00 and the clocks are turned 1 hour forward to 03:00:00 on the second Sunday of March. The DST ends when the local time is about to reach 02:00:00 and the clocks are turned 1 hour backward to 01:00:00 on the first Sunday of October. Custom Parameter (CUSTOM): By choosing this parameter, the user first selects the month, the place of the day in that selected month (Ex.: The selection of the second parameter in the second Saturday of March. It is selected as the week of the month.), the day, the time on which it will be turned forward for DST start. The user then selects the month, the place of the day in that selected month (Ex.: The selection of the second parameter in the second Saturday of September. It is selected as the week of the month.), the day, the time on which it will be turned backward for DST finish. Time Settings Menu: The time settings are done in this menu. There are 3 sub-menus. The changes which are meade in this menu are immediately applied. Date Menu(): It is displayed as dd.mm.yy. Clock Menu(): It is displayed as HH.mm.ss. Century Menu(CENTURY): The first two digits of the year which you re in is set in this menu. It is displayed as yyyy. The last two digits come from the date setting. When the user wishes to set this value it changes to yy--. It can be set between 19 and :53:40 CENTURY 1910 dd.mm.yy 20:53:40 HH.mm.ss CENTURY dd.mm.yy 20:43:50 HH.mm.ss Can be set between 19~25 CHANGED CHANGED CHANGED CENTRY :43:50 CENTRY
6 Display Settings Menu: The contrast is adjusted between 00 an 15 in this menu. CONTRAS 08 CONTRAS 08 Can be set between CONTRAS 05 CONTRAS 05 00~15 Holiday Lock Menu: In this menu, the set programs are deactivated for a time period which is entered by the user. 4 different holiday times can be entered by the user. The user must enter and approve the start date(as dd:mm), the start time(as HH:mm), the finish date(as dd:mm) and the finish time(as HH:mm) of a holiday. After the approval, HOLDAY X-FULL will appear on the screen. For an occupied holiday setting, EDIT ve DELETE options are available. If EDIT is selected for a holiday lock, the existing settings for that holiday lock can be observed and edited. If DELETE is selected for a holiday lock, the settings for that holiday lock is deleted. The changes are saved to the memory when the SAVE query is confirmed by the user while returning to the monitoring menu. See Program Example 3. Manual Mode Menu: The setting for leaving the manual mode after the device is set in manual mode is done in this menu. There are 3 parameters. The user can leave the manual mode with the DOWN button regardless of what parameter he chooses in this menu. Disabled Parameter(DISABL): When this parameter is selected; after the manual mode is enabled with the UP/DOWN buttons for any of the outputs, it must be disabled again with the UP/DOWN buttons. Program Parameter(NEXT-P): When this parameter is selected; after the relay/relays is/are activated or deactivated by a program in the program flow, the manual mode for the relay/relays will be disabled. Timer Parameter(R): When this parameter is selected; the user will be prompted to enter the time as HH:mm. The device will start to count back from the entered time when the manual mode is enabled for the relay/relays. If the time is entered as 23:59, the manual mode will be disabled after 23 hours and 59 minutes.if the time is entered as 00:01, the manual mode will be disabled after 1 minute. There is a special case if the time is entered as 00:00. With this entered time, the manual mode will be disabled after 1 minute too. Password Settings Menu: The activation and changing of a password is done in this menu. The factory default value for the password is. The 4 digit password is prompted before entering this menu. If the password is activated, it isn t prompted again before entering this menu since the password was entered before entering the main programming menu. Password Activation Menu: The password is activated or deactivated in this menu. It is activated as following: 16:40:51 Changes are saved SAVE yes no DISABL Selected parameter is shown Changes are discarded DISABL ACTIVE ACTIVE Selected parameter is shown 9 10
7 Password Change Menu: The password is changed in this menu. It is done as following: Factory Setting Menu: Selected parameter is shown ACTIVE CHANGE NEWPASS NEWPASS CHANGE 0001 CHANGD REENTER 0001 REENTER The device is returned to its factory settings in this menu. The 4 digit password is prompted before entering this menu. If the password is activated, it isn t prompted again before entering this menu since the password was entered before entering the main programming menu. The device returns to its factory settings when the SAVE query is confirmed by the user while returning to the monitoring menu. Time settings, relay operation count and relay operation time doesn t change. Version Information Menu: The software and hardware versions of the device is shown in this menu. Exit from Main Programming Menu: This menu is used to exit from the main programming menu. The ESC button can be used for this, too. If any changes are committed in the menus while in the main programming menu, an approval promt is shown. If there aren t any changes, the monitoring menu is shown directly. Factory Settings: Program P01...P32: FREE SAVE yes no Changes are saved Changes are discarded 16:40:51 Merge Function AND-1: FREE AND-2: FREE Password PASSWORD: PASSWORD STATUS:INACTIVE Regional Settings LANGUAGE: ENGLISH DAYLIGHT SAVING: EUROPEAN Display Settings CONTRAST:08 Holiday Lock -1: FREE -2: FREE -3: FREE -4: FREE Manual Mode RECOVRY : DISABLE Activation Time C1 : 0 C1 SHOT : 0 C2 : 0 C2 SHOT :
8 DIMENSIONS 35 mm 58 mm TYPE PK25 32 mm 48 mm 90 mm 35 mm 45 mm 62 mm Un L1 L2 L3 N CONNECTION DIAGRAM A1 C2 C A2 TECHNICAL FEATURES Electrical Features Operating Voltage (Un) Output Contact Refresh Time Power Consumption Accuracy Screen Size Program Number Battery Reserve Time Mechanical Features Equipment Protection Class Ambient Temperature Protection Class Installation Dimensions Weight Quantity in 1 Package Please look at the side label 2 C/O, 16 A / 4000 VA 1 sec. < 5 VA 1 sec./day 1,3 LCD Years Class II ( ) -5 C C IP20 Rail Mount PK25 0,2 kg 5 pcs 13 14
9 APPLICATION EXAMPLE 1: On every weekday, the C1 relay will be activated at 07:30 and be deactivated at 9 o clock. 16:40:51 3 sec. SET PROGRAM P01 FREE P01-OUT C1 P01-ON SUNRSE 00:00:00 00:00:00 07:30:00 ALL DAYS YES P01-OFF :00:00 00:00:00 09:00:00 PR0GRAM VALID CONFIRM YES ADJSTED PO PO1 FULL PROGRAM Note: The parameter selection in the example program diagrams must be done with the UP or DOWN buttons. This isn t described in the diagrams. The SET button is used for approval and the ESC button is used for returning to the previous selection. The diagrams are for P01 and the programming is done the same way for the other programs SAVE YES 16:41:21
10 APPLICATION EXAMPLE 2: C2 relay will be activated every monday at 18:30 and will be deactivated at 23:00 16:40:51 3 sec. PROGRAM P01 FREE P01-OUT C2 P01-ON SET +0:00:00 +0:00:00 18:30:00 ALL DAYS NO NDAY YES TUESDAY NO SUNDAY NO P01-OFF :00:00 PR0GRAM CONFIRM ADJSTED PO1 PROGRAM SAVE VALID YES PO1 FULL YES 16:41:21 00:00:00 23:00:
11 APPLICATION EXAMPLE 3: All programs will be deactivated between 22nd April 18:30 and 24th April 00:00. 16:41:21 3 sec. SET LOCK 1-FREE START S S :00 18:3o END E- E :00 00:0o SAVED 1-FULL LOCK SAVE YES 16:41:
12 MENU MAP 16:12:10 18:45:52 PO1-C1 05:44:00 C1-00 C1-SHOT 00 C2-00 C2-SHOT 00 Press for 3 seconds PROGRAM COMBINE FUNC HOUR COUNTR DE DE REGIONL DISPLAY LOCK MANUAL DE FACTORY VERSION INFOS EXIT MENU P01 P P P32 FREE AND-1 AND-2 FREE C1- C1- DELETE LANGUAG DAYLIGH CENTURY 2010 CONTRAS FREE RECOVRY DISABL FIRMWRE HARDWRE V000! If the SAVE query is not confirmed by the user while returning to the monitoring menu, the changes which are committed in the menus will be discarded(this doesn t apply to the Time Settings Menu). * The device shows the entered programs in the order of their program flow in the menu display. The programs can be browsed with the UP or DOWN buttons. The programs with a symbol next to them are the programs which didn t run yet (Monitoring Menu and Main Programming Menu screens are shown).
13 Press for 3 seconds. PROGRAM PO1 FULL P32 FREE EDIT / DELETE won t be shown for empty programs. PO1 EDIT P01-OUT C1 C2 Activation time setting Activation day selection Deactivation time setting PO1-ON 00:00:00 HH:mm:ss ALL DAYS NDAY FRIDAY PO1-OFF no no no yes yes yes 00:00:00 HH:mm:ss Time conflict query PROGRAM VALID CROSS PXX CONFIRM yes no ADJSTED PO1 The settings stay unchanged. DELETE CONFIRM yes no Program is deleted completely. FULL changes to FREE. Program stays unchanged
14 COMBINE FUNC HOUR COUNTR AND-1 FREE AND-2 FREE C1- DELETE AND-1 DISABL PXX PX FINISH CONFIRM NO ADJSTED AND-1 ADJSTED AND-1 AND-1 FREE AND-1 FULL The merge function does a logical AND operation. In the common timeframe of the merged programs, the corresponding relay becomes active. This function can be used if at least two programs are assigned for the same relay output. The user can browse between the parameters with UP or DOWN buttons. There is a DISABL parameter in these menus. When the user selects at least 2 programs, FINISH parameter becomes accessible in this menu instead of the DISABL parameter. After the programs which will be merged are selected with the SET button, " FINISH" parameter must be selected. DE DE PO1-C1 P31-C1 AND-1 AND-2 DAYLIGH REGIONL LANGUAG ENGLIS LANGUAG ENGLIS TURKIS DIL TURKCE RECOVRY In the settings observation menu, the set parameters of the sub-menus are shown. The sub-menu titles are shown on the menu flow diagram. These parameters are shown for 3 seconds. To prolong this time; ESC, UP or DOWN buttons should be pressed. If the SET button is pressed the shown parameter changes immediately. C1-SHOT DELETE YES 25 26
15 REGIONL LANGUAG E DAYLIGH SAVING DAYLIGH CUSTOM SUMMER DST Start Time Setting S NTH S WEEK S DAY january FIRST monday DST Finish Time Setting S HOUR WINTER W NTH W WEEK W DAY W HOUR 01 january FIRST monday 01 DAYLIGH ADJSTD DISABL europe decembe LAST sunday 23 decembe LAST sunday 23 usa 27 28
16 The last entered is shown CHANGED LOCK 1-FREE START S S- 00:00 END E :53:40 The last entered is shown. 20:53:40 20:43:50 CHANGED FREE, changes to FULL. SAVED E- 00:00 CENTURY 2011 The last entered CENTURY is shown. CENTURY 13 Can be set between 19~25 CHANGED CENTURY 4-FREE DISPLAY CONTRAS 08 The last entered value is shown. CONTRAS 08 Can be set between 00~15 CONTRAS 05 MANUAL DE RECOVRY DISABL Selected parameter is shown. RECOVRY DISABL NEXT-P R R-R 00:00 R-R 00:
17 If the password is active, it isn t prompted. DISABL Selected parameter is shown. DISABL FACTORY If the password is active, it isn t prompted. CONFIRM N0 WRONG 0001 ACTIVE WRONG 0001 YES SETTING LOADED VERSION INFOS FIRMWRE V0.00 CHANGE NEWPASS NEWPASS REENTER REENTER CHANGD HARDWRE V ENTRY WRONG EXIT MENU SAVE YES N :45:52 When this menu is selecetd without making any changes in the device menu, monitoring menu is shown without the SAVE prompt
DVB-T 730. User s Manual
EPG Program Reservation There are 10 program timers to bring up reminder for a reserved program. 20 seconds before the start of the reserved program, a pop-up window will remind viewer. If no further instruction,
Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
Operating instructions for built-in electronic timers with Day and Week programms. Series 884
Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction
BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product
System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611
DT1-IK 2CSM204275R0611 DT1-IK/24V 2CSM204285R0611 DT1-IK/DCF 2CSM204295R0611 DT2-IK 2CSM204325R0611 System pro M GB -1- WEEKLY DIGITAL TIME SWITCH + PROGRAMMING KEY I -11- INTERRUTTORE ORARIO DIGITALE
Wireless Thermostats 230v and Battery Operated Instruction Manual
Wireless Thermostats 230v and Battery Operated Instruction Manual For models: JGSTATW2W JGSTATW2B JGSTATW1W JGSTATW1B Contents Box contents: Wireless Thermostats 230v and Battery Operated Instruction Manual
ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)
ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A) ATEL TEKNOLOJİ ve SAVUNMA SANAYİ A.Ş. ATEL TECHNOLOGIE and DEFENSE INDUSTRY Inc. Co. Hilal Mah. 677. Cad. No: 9 06550 Çankaya ANKARA / TÜRKİYE
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
IX Support Tool Setting Manual
IX System IP network-compatible intercom IX Support Tool Setting Manual Software version 2.0.0.0 or later Before configuring and using the system, read Setting Manual and Operation Manual (PDF) carefully.
EK908FHL - Thermostat for floor heating
EK908FHL - Thermostat for floor heating EK908FHL is a programmable thermostat designed for floor warming application or helping to limit floor temperature. This thermostat can be used for hot water radiant
Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60. General information. Overview. Set language
Time switch D21-1-channel 4 126 31 / 32 / 33-047 61 / 63 / 6047 60! Safety notes GB This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation
Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)
Weather Direct Displays show Lost Forecast (blank boxes in the picture icons) Many routine events can cause a Lost Forecast situation. Examples include: Power outage Change batteries Internet down in your
SMC 3000 Series Master Clock Programming Manual (V3) Table of Contents. Getting Started.. Page 2. Setting the Time of Day...
User Password (default is 1111) GETTING STARTED Getting Started.. Page 2 SETTING THE TIME Setting the Time of Day... Page 3 SETTING THE DATE Setting the Date. Page 4 EVENTS Programming Events..... Pages
Motion Activated Camera User Manual
Brinno MAC200 User Manual Last Modified on 12/23/2015 7:51 pm EST Motion Activated Camera User Manual www.brinno.com Register@online http://www.brinno.com/support/register.html contact us: [email protected]
DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE
DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE IMPORTANT!!! PLEASE READ BEFORE OPERATING YOUR DVR Ready to go, right out of the box! This digital video recorder is designed to function right out of the box.
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
MAGICAR M871A. Car alarm with two-way remote User s guide
MAGICAR M871A Car alarm with two-way remote User s guide EN MAGICAR M871A Car alarm with two-way remote User s guide TABLE OF CONTENTS Table of contents...2 1. Important notice...4 2. Introduction...4
Drayton Digistat +2RF
Drayton Digistat +2RF T Programmable Room Thermostat Wireless 24 Hour Model: RF700/22090 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
Point of view HDMI Smart TV dongle Mini RF Keyboard
Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions
User s Manual for Fingerprint Door Control Software
User s Manual for Fingerprint Door Control Software Foreword The naissance of F7 indicated that fingerprint reader enters into professional door control domain. That s why we developed this software to
Mini Timer Owner's Manual. Model MT13A
Mini Timer Owner's Manual Model MT13A Contents Introduction...3 Quick Tour...5 How to program a timed event...6 Special programming buttons...6 Setting up the Mini Timer...7 Setting the clock...7 Controlling
one Managing your PBX Administrator ACCESSING YOUR PBX ACCOUNT CHECKING ACCOUNT ACTIVITY
one Managing your PBX Administrator ACCESSING YOUR PBX ACCOUNT Navigate to https://portal.priorityonenet.com/ and log in to the PriorityOne portal account. If you would like your web browser to keep you
PAR+ES Controller. Operation Manual MANUAL LOCAL MAXI A B C D E F M1 M2
PAR+ES Controller Operation Manual MODE OFF MANUAL LOCAL MAXI A B C D E F M M PROGRAMMING S OPERATING S P/N: 65777-0 65777 Rev B (PAR+ES operations manual (of ENG)) source.indd /0/007 8:40:7 AM Contents
EZ DUPE DVD/CD Duplicator
EZ DUPE DVD/CD Duplicator User s Manual Version 3.0 0 TABLE OF CONTENTS Introduction 2 Setup 11 LCD Front Panel Overview 2 o Auto Start Time 11 Menu Overview 3-5 o Display Mode 12 Functions 6 o Button
DVB-T2 DIGITAL TV BOX
DVB-T2 DIGITAL TV BOX QUALITY OF DIGITAL TELEVISION MT4159 User Manual EN 2 Index Index...2 Introduction...3 Front panel...3 Rear panel...3 Remote control...4 Hardware configuration...5 Connecting tuner
Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
Neonixie 6 Digit Nixie Clock Controller Introduction and Assembly
Neonixie 6 Digit Nixie Clock Controller Introduction and Assembly Thank you for purchasing our 6 Digit Nixie Clock Controller. Our clock controller is user friendly and has many of the features most requested
Digital Photo Frame User s Manual
Digital Photo Frame User s Manual MPN: UM00843EU001 Questions? Need Some Help? This manual should help you understand your new product. If you still have questions, call our help line found on the insert
Operation Guide 3M-22
Operation Guide 3M-22 TEMP UP Target Temp Time Reset TEMP DOWN Control Panel Heat/Cool Mode Switch Fan Switch Battery Compartment Statement of use: The 3M-22 can be used with - millivolt, 24VAC single
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
OCSM Series. High Resolution Digital Crane Scale. User Guide
OCSM Series High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 3 5. Display & Keys... 3 Scale & Remote Keys... 3 Indicators... 4 Message...
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
Inventory Manager. Getting started Usage and general How-To
Getting started Usage and general How-To Before you begin: Prerequisites: o SQL Server 2008 R2 Express Edition with the default SQLEXPRESS instance MUST be installed in order to use. If you do not have
Welcome to Smart Pay As You Go
Welcome to Smart Pay As You Go The Pay As You Go you ve been waiting for Welcome to Smart Pay As You Go, the new way of paying for your energy and keeping costs down. From now on, topping up will be easier
SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016
SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016 1. GENERAL DESCRIPTION The SPY-BATT is a device that allows to monitor the state of your battery. The SPY-BATT stores over time the
The Parts of the System
2 The Parts of the System THE RECEIVER THE RECEIVER FRONT PANEL Power Light This green light on the receiver front panel lights up when the receiver is turned ON. This light flashes when the receiver memory
Cisco IP Phone Training
Cisco IP Phone Training Objectives Overview Cisco IP Phone Layout Basic Phone Functions Voicemail Questions 2 Foot Stand Release Press the foot stand adjustment knob on the right-hand side of the phone.
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
EBDSPIR-PRM, EBDSPIR-PRM-IP
Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional
Advanced User s Guide
Advanced User s Guide FAX-2840 FAX-2845 FAX-2940 Not all models are available in all countries. Version 0 UK/IRE User s Guides and where do I find them? Which Guide? What s in it? Where is it? Product
PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL
PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL 1 CODES AND OPERATION CODES The factory set Master Code is #1234. This should be changed immediately after installation (see Program 10). The Master
1. INTRODUCTION FEATURES 2. PROGRAMMING
1. INTRODUCTION Mono phase compensation systems are not useful in plants where unbalanced loads exist. In such plants compensation has to be done by measuring all 3 phase parameters individually. Devices,
Watch GPS Instruction Manual. If you have any other questions or concerns, please call 1-800-777-7899 or go to www.izzo.com.
Watch GPS Instruction Manual If you have any other questions or concerns, please call 1-800-777-7899 or go to www.izzo.com. Mail to: IZZO golf 1635 commons pkwy macedon, ny 14502-9191 [ Please place inside
Zebra Ethernet. Frequently Asked Questions
Zebra Ethernet Frequently Asked Questions Zebra Technologies Corporation Card Imaging Division 1001 Flynn Road Camarillo, CA 93012 USA Phone: (805) 579-1800 Fax: (805) 579-1808 www.cards.zebra.com 2004
Fused Spur Time Switch
Fused Spur Time Switch Model No. FST24 24 Hour Timer Model No. FST77 7 Day Timer Installation & Operating Instructions 1. General Information Illuminated screen Sets programmes Sets time and date Reset
FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel
ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE
Athena. User s Manual Version 1.0e. 1 to 3 targets 1 to 7 targets 1 to 11 targets. CD/DVD Duplicator Controller
Athena User s Manual Version 1.0e 1 to 3 targets 1 to 7 targets 1 to 11 targets CD/DVD Duplicator Controller CONTENTS 1. INTRODUCTION.. 2 2. Features.. 2 3. Specifications.. 3 4. Hardware Installation
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
G-100/200 Operation & Installation
G-100/200 Operation & Installation 2 Contents 7 Installation 15 Getting Started 16 GPS Mode Setup 18 Wheel Sensor Mode Setup 20 Fuel Calibration 23 Basic Operation 24 Telemetery Screen 27 Entering a Distance
Manual. PC-Software Save`n carry PP 50 pro
Manual PC-Software Save`n carry PP 50 pro Directory 1 Directory 1 Directory... 2 2 Introduction... 3 2.1 Product description... 3 2.2 Pictograms... 3 2.3 Software installation... 4 2.4 Hardware installation...
MTS Power Products MIAMI FL 33142 ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual
MTS Power Products MIAMI FL 33142 ATS-22AG Automatic Transfer Switch And Control PLC Operator s Manual Dedicated Single Phase Transfer Switch With Touch Screen Controls Normal Power Connections Emergency
Patrol Master Software
Handheld Guard Tracking System PATROL Patrol Master Software Software version : 3.1.16 Document version: Rev. C Contents 1. Introduction... 3 1.1 Purpose and main features... 3 1.2. Requirements... 3 1.3.
3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19
3NNet USERS MANUAL KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19 RACK MOUNTABLE 4 / 8 / 16 PORT PS2 KVM SWITCH Rev 1.1 TABLE OF CONTENTS INTRODUCTION.. 3 FEATURES... 3 PACKAGE CONTENTS........
LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators
LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators KULLANICI KILAVUZU USER MANUAL TR/EN TÜRKÇE ENGLISH Publisher ARKEL Elektrik Elektronik Ticaret Ltd. Şti. Date of issue
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions
ETHERNET IRRIGATION CONTROLLER Irrigation Caddy Model: ICEthS1 User Manual and Installation Instructions I R R I G A T I O N C A D D Y M O D E L : I C E T H S 1 User Manual and Installation Instructions
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
Table of Contents. Mitel 3000 Getting Started Guide
Get Started Guide Table of Contents GUIDE TO SYSTEM DOCUMENTATION...1...1 Phone Quick Reference Guide...1 Administrator s Manual...1 Broadband Module Manual...1 IP Phone Quick Reference Guide...1 Documentation
PAC1 Door Access Controller
PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,
ADVANCED OUTLOOK 2003
ADVANCED OUTLOOK 2003 Table of Contents Page LESSON 1: MANAGING YOUR MAILBOX LIMITS...1 Understanding Mailbox Limits...1 Setting AutoArchive...3 AutoArchiving Your Folders...5 Deleting Items Automatically...7
WHAT ELSE CAN YOUR HOME PHONE DO?
visit a Telstra store 13 2200 telstra.com/home-phone WHAT ELSE CAN YOUR HOME PHONE DO? Everything you need to know about the features that make your home phone more helpful, flexible and useful C020 FEB16
SOFTWARE USER GUIDE. Aleratec. Part No. 330113, 330113EU. 1:10 USB 3.0 Copy Cruiser Mini
SOFTWARE USER GUIDE Aleratec 1:10 USB 3.0 Copy Cruiser Mini Part No. 330113, 330113EU Copyright/Model Identification The content of this manual is for informational purposes only and is subject to change
BODY ELECTRICAL TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK. ASSIGNMENT Version 1.8 WORKSHEETS. http://www.autoshop101.com
BODY ELECTRICAL ASSIGNMENT Version 1.8 WORKSHEETS TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK http://www.autoshop101.com Developed by Kevin R. Sullivan All Rights Reserved TOYOTA Table of Contents Wiring
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
Fingerprint Time & Attendance. User s Manual
Fingerprint Time & Attendance User s Manual Contents 1. Specification...3 2. Basic Introduction of Smack Bio3000...4 1) User and Manager...4 2) Working status...4 3) Enrollment and identification...5 4)
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
STIDistrict SQL 2000 Database Management Plans
STIDistrict SQL 2000 Database Management Plans Overview STI recommends that users create SQL database maintenance plans to maintain the integrity of the STIDistrict database. Database maintenance plans
Locker Rental Software
Locker Rental Software (ELS NET Software) DESCRIPTION POS software for renting lockers Sales & Financial Reports Locker management inženiring d.o.o. Špruha 19 1236 Trzin Slovenia tel.: +386 1 561 07 40
Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version www.pdffactory.com
Time Recorder User Manual 1 (1) Specifications: 1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase. 2. Power consumption Normal 2W (MAX 30W) 3. Standard time signal Quartz
Advanced User s Guide
Advanced User s Guide MFC-J6920DW MFC-J6925DW Version A UK/IRE/GEN User's Guides and where do I find them? Which Guide? What's in it? Where is it? Product Safety Guide Quick Setup Guide Basic User s Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
User s Manual. Management Software for Inverter
WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...
Digital Video Recorder Client and Network Manual V1.1 Table of Contents
Table of Contents I. PC Client S/W User s Manual...2 1. Introduction of.avh Files Player...2 1.1 Introduction of Function Keys...3 1.2 Specific Operation...3 2. Introduction of DVR Network Remote Client...5
Security module CG2 User manual
Security module CG2 User manual TRIKDIS, JSC Draugystes str. 17, LT-51229 Kaunas LITHUANIA E-mail [email protected] Web http://www.trikdis.lt This manual is furnished to help You understand Your security
AS-525. AxTrax Access Control Management Software. Software Manual
AS-525 AxTrax Access Control Management Software Software Manual August 2010 Table of Contents Table of Contents 1. Introduction... 5 1.1 System Features... 5 1.1.1. Access Control... 6 1.1.2. Access
ADVANCED USER S GUIDE
ADVANCED USER S GUIDE MFC-J6910DW Version 0 UK/IRE/GEN User's Guides and where do I find it? Which manual? What's in it? Where is it? Safety and Legal Quick Setup Guide Basic User's Guide Advanced User's
DVR GUIDE. Using your DVR/Multi-Room DVR. 1-866-WAVE-123 wavebroadband.com
DVR GUIDE Using your DVR/Multi-Room DVR 1-866-WAVE-123 wavebroadband.com Table of Contents Control Live TV... 4 Playback Controls... 5 Remote Control Arrow Buttons... 5 Status Bar... 5 Pause... 6 Rewind...
Deposit Direct. Getting Started Guide
Deposit Direct Getting Started Guide Table of Contents Before You Start... 3 Installing the Deposit Direct application for use with Microsoft Windows Vista... 4 Running Programs in Microsoft Windows Vista...
V2.0 Attendance System Hardware Suite Guide Instructions Manual
CONTENTS TA920 V2.0 Attendance System Hardware Suite Guide Instructions Manual Chapter One - Introduction 1.1 Communication Port 5 1.2 Power Source Control. 5 1.3 Attendance Users. 6 1.4 Registering Ways..
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Windows XP Pro: Basics 1
NORTHWEST MISSOURI STATE UNIVERSITY ONLINE USER S GUIDE 2004 Windows XP Pro: Basics 1 Getting on the Northwest Network Getting on the Northwest network is easy with a university-provided PC, which has
Rack Mount LCD KVM Assembly Installer/User Guide
Rack Mount LCD KVM Assembly Installer/User Guide Japanese Notification Chinese Notification Taiwanese Notification Rack Mount LCD KVM Assembly Installer/User Guide Avocent, the Avocent logo and The Power
Video Baby Monitor System. User Guide
Video Baby Monitor System User Guide What s inside Welcome!... 2 Getting started... 3 Tour of the system... 7 Everyday use...13 Cameras... 14 Motion/Alerts... 18 Recording... 21 Playing Back Pictures and
Remote Terminal Functionality
Remote Terminal Functionality The timeqplus (TQP) Time & Attendance Server can transfer data to and from remote TQ600 terminals (terminals not connected via cables) through the use of a USB Pen Drive (sometimes
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance
LCD MONITOR / 8 CHANNEL DVR COMBO
LCD MONITOR / 8 CHANNEL DVR COMBO Overview - New System Setup SERIES: SG17LD800 & SG19LD800 www.lorexcctv.com Copyright 2007 LOREX Technology Inc. New System Setup - Overview New System Setup - Overview
ADVANCED USER S GUIDE
ADVANCED USER S GUIDE MFC-9970CDW Version A USA/CAN User's Guides and where do I find it? Which manual? What's in it? Where is it? Safety and Legal Quick Setup Guide Basic User's Guide Advanced User's
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies
REV. G Cooler is Better! TM Owner s Manual Walk-in Monitoring System 100 Used in UL Listed Door Panel Assemblies American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352)
Electronic Time Recorder
CP-3000 Electronic Time Recorder User s Guide PROPRIETARY NOTICE This document contains proprietary information and such information may not be reproduced in whole or in part without the written permission
Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC100-240V DC12-24V AC100-240V. Output indicator
SERIES Electronic Preset Counter Instruction Manual Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in