LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators
|
|
- Megan Armstrong
- 8 years ago
- Views:
Transcription
1 LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators KULLANICI KILAVUZU USER MANUAL TR/EN
2 TÜRKÇE ENGLISH Publisher ARKEL Elektrik Elektronik Ticaret Ltd. Şti. Date of issue 2013 Document version V1.4 Hardware version V1.5 Software version V1.2 Şerifali Mah. Bayraktar Bulvarı Sehit. Sk. No:32 Umraniye Istanbul TURKIYE TEL: ( ) Fax: ( ) This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the right to make changes and improvements to any of the products described in this document without prior notice. Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause. ARKEL 20 LCD240X128A
3 TÜRKÇE ENGLISH CONTENTS 1. INTRODUCTION FUNCTIONAL SPECIFICATIONS: TECHNICAL SPECIFICATIONS: OVERVIEW ELECTRICAL CONNECTIONS INPUT SIGNALS ACCORDING TO INPUT MODE DISPLAY FIELDS DEVICE CONFIGURATION CONFIGURATION WITH MENU & PUSH BUTTONS CONFIGURATION WITH LCD240128A UPLOADER PC Connection Configuration Import Pictures Section Settings Section Picture Assignments Section Floor Texts Section Uploading the settings to LCD240128A memory MECHANICAL ASSEMBLY ARKEL 21 LCD240X128A
4 TÜRKÇE ENGLISH 1. Introduction LCD240X128A is a graphic LCD display with a resolution of 240 by 128 pixels. It is specially designed for lift applications. It can be assembled either to the car or to the landings. It can present floor marking, direction arrow, subtitle, company logo, out of service picture, overload picture, time and date. Also user editable pictures and logos can be loaded to system for special indications Functional specifications: - Supports for up to 32 floors (48 floors with CANbus mode for ARL-500 control system) x 128 pixel resolution (114 mm x 64 mm active area) - General purpose displaying panel for car and landings - Supports for Gray code, Binary code, Arkel counter mode, 7-segment display mode and CANbus (with ARL-500) mode - Device programming with a menu & buttons on LCD240128A or with a PC by using LCD240128A Uploader software - Picture programming individually for each floor - Programmable static / animated arrow - Programmable static / animated subtitle - Programmable out of service and overload picture - Programmable logo - Selectable letters or numbers (-, 0 9, A Z) for floor texts - Saving or loading your personal settings with LCD240128A Uploader - User pictures and logos can easily be added to system by pc software - Positive or negative common selectable input signals - Presentation of time and date (available only with CANbus mode) - Screensaver mode to reduce power consumption (only available with CANbus mode) - Optional Turkish and English menu language ARKEL 22 LCD240X128A
5 TÜRKÇE ENGLISH 1.2. Technical specifications: Display resolution 240 x 128 pixels (H x V) Active area 114 mm x 64 mm LCD type negative, blue Backlight white LED Contrast setting with trimmer potentiometer Operating voltage range VDC Stand by current consumption screensaver mode OFF: 1.4W ( VDC) screensaver mode ON: 0.7W ( VDC) Control interface - parallel mode position input: Binary/Gray/Arkel counter/7-segment - serial mode position input: ARL-500 CANbus Parallel mode input voltage range Parallel mode input signal common Programming interface Device configuration Physical dimensions 0 30 VDC Weight Operating temperature 0 70 C - selectable positive or negative common for inputs G0 G8, 31 and 32 with terminal GCOM - fixed low voltage (1000) for inputs 02, 804 and DD RS-232 serial interface for PC connection (via LCD240128A Uploader software cable) - LCD240128A Uploader software - 4 push buttons and displayed menu for CANbus input mode: 159 mm x 125 mm x 26 mm for parallel input mode: 159 mm x 125 mm x 31 mm (7mm wide breakable pcb parts at both side) 300 g (max.) ARKEL 23 LCD240X128A
6 TÜRKÇE ENGLISH 2. Overview Figure-1: Back side view 1 2 pcs. big size CANbus connectors (Not used in parallel mode) 2 Small size CANbus connector (Not used in parallel mode) 3 Input terminals for parallel mode operation (Not used in CANbus mode) 4 LCD display contrast setting 5 4 push button for menu control 6 Buzzer (Has no function) 7 MCU programming socket (Must not be used by user!) 8 PC programming socket for LCD240128A Uploader software cable 9 Memory chip 10 LCD module connection socket 11 7mm wide breakable pcb parts at both side 12 LCD module fixing holes 13 Mounting holes ARKEL 24 LCD240X128A
7 TÜRKÇE ENGLISH 3. Electrical connections G0 G8: parallel mode position inputs according to the input mode 31: Down direction arrow 32: Up direction arrow GCOM: Common of signals 02: Out of service 804: Over-load DD: Reserved input (-) (+) 24V supply voltage for parallel input mode Big size CANbus connector for CANbus input mode (+24V, 0V, CANH, CANL) Small size CANbus connector for CANbus input mode (+24V, 0V, CANH, CANL) PC programming socket for LCD240128A Uploader software Figure-2: Electrical connections ARKEL 25 LCD240X128A
8 TÜRKÇE ENGLISH 3.1. Input signals according to input mode Input mode Gray code (max. 32 stops) Binary code (max. 32 stops) M1 counter ** (max. 32 stops) 7-Segment (max. 16 stops) Input signals G0 G1 G2 G3 G4 G5 G6 G7 G GCOM M0 M1 M2 M3 M * M0 M1 M2 M3 M * M * A B C D E F G BC G * CANbus (max. 48 stops) These inputs and 24Vdc supply are not used in CANbus operation mode. Only CANbus connection is needed. *: when connected to 100: inputs G0 G8, 31, 32 are low active when connected to 1000: inputs G0 G8, 31, 32 are high active **: when M1 counter mode is used, in case the mains power is gone, the position of car cannot be kept in device s memory. To make the system learn the position of car again, the elevator must be moved to the bottom floor. ARKEL 26 LCD240X128A
9 TÜRKÇE ENGLISH 4. Display fields Display is divided to four sub-areas. Names of these fields are as follows: Logo field Arrow field 1 2 Floor text field Floor picture field Collection arrow field 3 4 Date and time field Subtitle field Picture-1: Display fields 5) Logo / direction arrow / collection arrow field - User editable logo picture is displayed in this field when the elevator is resting on a floor and when there are no up/down hall calls. - The up/down direction arrow is displayed on this field while the elevator is moving. The direction arrow can be adjusted either static or sliding. - The up/down collection arrow is displayed on this field when the elevator is resting on a floor and when it will be collecting upwards/downwards. This appearance is active only when display is used in hall. 6) Floor text / floor picture field - In normal situation 2 character text floor names are displayed in this field (for example: B2, B1, 0, 1, 2, 3,...) - If a picture assigned for a floor, the defined picture will be displayed when the elevator stops on that floor. This appearance is active only when display is used in car. 7) Date and time field This field is only active when the display is used with ARL-500 Elevator Controller. When enabled, the date and time is displayed in this field continuously. 8) Subtitle field This field is a subtitle text area. You can enter a text of 8x40 characters to be displayed in this area. The subtitle text can be adjusted either static or scrolling. ARKEL 27 LCD240X128A
10 TÜRKÇE ENGLISH 5. Device configuration LCD240X128A display can be configured in two different ways: - with LCD240X128A Uploader PC application tool - with menu & 4 push buttons on LCD240X128A LCD240128A Uploader software and a PC connection is required only if you want to upload your own pictures into the board. All functionality of the LCD240128A Uploader software except "uploading images" is also accessible directly by the embedded menu inside the board. The embedded menu of the board can be activated anytime by pressing any of the four push-buttons located on the back face of the board Configuration with Menu & Push buttons With the help of the setup menu the user can make changes to properties of the display. 4 push buttons are assigned to browsing of the menu. G E N E R A L S E T T I N G S I n p u t t y p e : C A N B U S A r r o w a n i m a t i o n : O f f S u b t i t l e t e x t : > > > S u b t i t l e s t y l e : S c r o l l i n g F l o o r t e x t s : > > > P i c t u r e s : > > > D a t e & T i m e : O n B o a r d t y p e : C a r d i s p l y F l o o r : -- S c r e e n s a v e r : O f f S a v e a n d e x i t : < < < E x i t w i t h o u t s a v e : < < < Picture-2: Menu & push buttons on board Pressing the ENT push button activates the setup menu. Menu items are scrolled by buttons + (up) and (down). ESC and ENT buttons changes the value of the selected item. ENT steps to the next value and ESC to the previous value. The options at the down side of the menu are used to exit menu either with saving changes or without saving changes to the menu. >>> means press right (ESC) push button and <<< means press left (ENT) push button. Setup menu: - Input type - Arrow animation - Subtitle text - Subtitle style - Floor texts - Pictures - Date & Time - Board type - Floor - Screensaver Note: In this section the menu items will be described briefly. The detailed description for these items can be seen in the configuration with LCD240128A Uploader section. ARKEL 28 LCD240X128A
11 TÜRKÇE ENGLISH Input type: Gray code, Binary code, M1 counter, 7-Segment and CANbus Arrow animation: On/Off Subtitle text: A text of 8x40 characters can be entered to be displayed in the subtitle field by using the submenu and the character set in this area. Cursor position in the text area S U B T I T L E T E X T E N T R Y A R K E L E l e k t r i k E l e k t r o n i k w w w. a r k e l. c o m. t r T e l : Subtitle text area Character set area Cursor position in the character set area A B C D E F G a b c d e f g F W D H I J K L M N h i j k l m n * / R E W O P Q R S T U o p q r s t u ( ) < > ;?! O V E R V W X Y Z v w x y z #! $ D E L., :?! &., :?! & Q U I T Picture-3: Subtitle text entry Submenu to control the subtitle text area and exit submenu After entering this window, the cursor will appear on the character A in the character set area. In this area, the cursor is scrolled between the characters and the submenu items by pressing the push buttons. Pressing and holding any push button writes the selected character to the position of the cursor in the subtitle text area. The submenu items on the right side of this area can be activated by pressing and holding any push button while the cursor shows that item. FWD item moves the cursor forward one character in the text area and REW item moves it backward. By pressing and holding on the OVER item it will be changed as INSERT. Which is not visible is the active item. OVER means the activated character will be overwritten. INSERT means the selected character will be inserted after the cursor. DEL item deletes the active character and moves the text backward one character. By pressing and holding on the QUIT item, display exits this submenu and returns to GENERAL SETTINGS menu. Subtitle style: Scrolling/Static Floor texts: This submenu is used to assign 2 character text floor names to stops. This setting is only needed when LCD240128A will be used with a controller board except ARL-500. When used in CANbus input mode with ARL-500, these settings are ignored. Stop numbers Floor texts F L O O R T E X T S E T T I N G S F : - 2 F : 9 F : 2 0 F : - 1 F : 1 0 F : 2 1 F : 0 F : 1 1 F : 2 2 F : 1 F : 1 2 F : 2 3 F : 2 F : 1 3 F : 2 4 F : 3 F : 1 4 F : 2 5 F : 4 F : 1 5 F : 2 6 F : 5 F : 1 6 F : 2 7 F : 6 F : 1 7 F : 2 8 F : 7 F : 1 8 F : 2 9 F : 8 F : 1 9 Exit menu P R E V I O U S P A G E : < < < Picture-4: Floor text settings ARKEL 29 LCD240X128A
12 TÜRKÇE ENGLISH After entering this window, the cursor will appear on the first stop F-00. Stop numbers are scrolled by buttons + (up) and (down). First pressing the ESC (right) push button activates the first digit of selected item. Second pressing steps to next digit and third pressing deactivates the item. While a floor text item is active + (up) and (down) buttons change the value of the selected digit. ENT (left) button exits submenu, when the cursor shows PREVIOUS PAGE item. Pictures: In this screen, the pictures in the memory slots can be assigned for floors (0-31), out of service picture, overloaded picture, frame picture, frame & logo picture, fire picture (only with CANbus mode), down collective picture and up collective picture. The item which the picture is assigned to (floors or other items) F L O O R P I C T U R E A S S I G N M E N T FLR- 0 0 P I C T. : 0 5 Slot number of the selected picture Selected picture U p o r D o w n b u t o n t o s e l e c t f l o o r s. L e f t o r r i g h t t o s e l e c t P i c t u r e. U p + D o w n e x i t. Picture-5: Floor picture assignment + (up) or (down) buttons changes the item which the picture will be assigned to. ENT (left) or ESC (right) buttons changes the picture. Pressing Up and Down buttons together exits this submenu. Date & Time: On/Off Board type: Car display/hall display Floor: The stop number where the display is located on when used as hall display Screensaver: A screensaver mode is added to V15 which can be activated in the menu. If this parameter is enabled from the LCD menu, it turns off the backlight of LCD at the end of the car light delay time and thus decreases the power consumption of the LCD. This mode is only available with the systems that use CANbus connections. ARKEL 30 LCD240X128A
13 TÜRKÇE ENGLISH 5.2. Configuration with LCD240128A Uploader With LCD240128A Uploader software and a PC connection you can easily make your device configuration. You can upload your pictures, logos and you can write subtitle and determine floor texts PC Connection PC connection socket Picture-6: PC connection socket Picture-7: PC connection cable - Connect one end of the connection cable (white connector) to the terminal designated as "PC" on the LCD240128A board. Connect the other end of the cable to a free serial port on your computer. - Attach a VDC power supply to the connectors on the board (100:+; 1000:-) Configuration LCD240128A Uploader Windows application consists of four sections which can be selected by the top tab bar: 5. Import Pictures 6. Settings 7. Picture assignments 8. Floor texts Picture-8: LCD240128A Uploader top bar ARKEL 31 LCD240X128A
14 TÜRKÇE ENGLISH Import Pictures Section Picture-9: Import picture section Import Pictures tab is used to upload B/W bitmap pictures from your computer into the memory of LCD240128A board. There are 64 different picture slots in the memory that pictures can be uploaded. To upload pictures, follow these steps: 4. From the "Picture slots" listbox, select the slot that you want to upload the picture into. If you select a slot that already has a picture, the picture will be overwritten. 5. Click on Import bitmap button. In the "Open file" dialog, select a picture on your computer. The selected picture must be mono-color and in the bitmap format. If you want to upload a picture of a different format (e.g:.jpg,.gif...), you can use Paint or a similar program to convert your pictures into Mono-color (1-bit) BMP format. When a picture is selected, it will be displayed on the "Preview" frame. 6. Repeat steps 1 & 2 for all the pictures that you want to use. ARKEL 32 LCD240X128A
15 TÜRKÇE ENGLISH Settings Section Picture-10: Settings section Input signal mode: LCD240128A board can operate with several input signal types. These are: Gray code, Binary code, M1 counter, 7-Segment and CANbus. CANbus input type is only for use with Arkel ARL-500 Elevator Controller and it is the recommended mode when using with ARL-500. Please refer to connection diagram for the specific input type that will be using. Arrow animation: This option selects whether the arrow signal will be sliding vertically during travel or not. Date and Time: This setting only works when used with ARL-500 Elevator Controller. When enabled, the date and time is displayed under the floor text continuously. Adjustment of the realtime clock must be made from the ARL-500 "Date & Time Settings" menu. Subtitle: There is a subtitle text area on the bottom side of the display. You can enter a text of 8x40 characters to be displayed in this area. If "Static text" is selected, each line of the text will be displayed in turn for 5 seconds continuously. If "Scrolling text" is selected, all the text will be scrolled from right to left like a ticker. Board type: Car display/hall display is selected. Floor: The stop number where the display is located on when used as hall display is selected. ARKEL 33 LCD240X128A
16 TÜRKÇE ENGLISH Picture Assignments Section Picture-11: Picture assignment section In this section, you can assign the pictures in the memory slots for different situations: Out of service: The selected picture will be displayed when elevator is out of service Overloaded: The selected picture will be displayed when elevator is overloaded Frame: This is the picture that other texts will be overlaid on while the elevator is moving. Frame with Logo: This is the picture that other texts will be overlaid on when the elevator is resting on a floor and when there are no up/down hall calls Up Collective: This is the picture that other texts will be overlaid on when the elevator is resting on a floor and when it will be collecting upwards. Down Collective: This is the picture that other texts will be overlaid on when the elevator is resting on a floor and when it will be collecting downwards. Floor-X: If there is a picture selected for this item, that picture will be displayed when the elevator stops on floor-x (cancelling any other rules). Picture No: To assign pictures, first select situation from the "Situation" list box. Then select the picture that will be assigned for that situation (from the "assigned picture" list box). ARKEL 34 LCD240X128A
17 TÜRKÇE ENGLISH Floor Texts Section Picture-12: Floor texts section This section is only needed when LCD240128A will be used with a controller board except ARL When used in CANbus input mode with ARL-500; these settings are ignored. It is used to assign 2 character text floor names to stops. For example: 1:B2, 2:B1, 3:0, 4:1, 5:2, 6:3, ARKEL 35 LCD240X128A
18 TÜRKÇE ENGLISH Uploading the settings to LCD240128A memory After all settings are done, follow these steps to upload them into the flash memory: 4- Make the connection between LCD240X128A and PC. 5- On the Windows program, select the COM port that you have connected the cable. Picture-13: Uploading the settings to display 6- Click on "Upload to LCD" button. The progress window below will be displayed and data will be uploaded to the LCD240128A flash memory. This operation may take up to 4-5 minutes. Picture-14: Uploading status window ARKEL 36 LCD240X128A
19 TÜRKÇE ENGLISH 6. Mechanical assembly Device has several holes for mounting. Refer to mechanical drawings for accurate positioning of fixing points and active display area. Figure-3: Diemensions H (for CANbus input mode): 26 mm H (for parallel input mode): 31 mm H ARKEL 37 LCD240X128A
20 Bu sayfa bilerek boş bırakılmıştır. This page is intentionally left blank.
LiftMedia. Asansörlere Özel TFT LCD Gösterge, Müzik ve Anons Sistemi TFT LCD Display, Music and Announcement System for Lifts
LiftMedia Asansörlere Özel TFT LCD Gösterge, Müzik ve Anons Sistemi TFT LCD Display, Music and Announcement System for Lifts KULLANICI KILAVUZU USER MANUAL TR/EN Publisher ARKEL Elektrik Elektronik Ticaret
More informationARKEL Vision ARL-500 Uzaktan Erişim ve İzleme Sistemi ARL-500 Remote Control and Monitoring System KULLANICI KILAVUZU USER MANUAL TR/EN
ARKEL Vision ARL-500 Uzaktan Erişim ve İzleme Sistemi ARL-500 Remote Control and Monitoring System KULLANICI KILAVUZU USER MANUAL TR/EN Publisher ARKEL Elektrik Elektronik Ticaret Ltd. Şti. Document Date
More informationFLOOR INDICATORS CATALOGUE
FLOOR CATALOGUE All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 18 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/19 LCD LKG240128C
More informationUser manual LCD 240-2xx
Kapitelbezeichnung Kapitelbezeichnung X.X Unterpunkt User manual 2xx 2VS 2VP 2HS 2HSC 2HP 2HPC Kapitelbezeichnung Kapitelbezeichnung X.X Unterpunkt Memo SCHAEFER GmbH Winterlinger Str. 4 72488 Sigmaringen
More informationFLOOR INDICATORS CATALOGUE 2007
FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD
More informationFLOOR INDICATORS CATALOGUE 2007
FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD
More informationLIFT CONTROL SYSTEMS CATALOGUE 2009
LIFT CONTROL SYSTEMS CATALOGUE 2009 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More informationHow To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating
GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: sec.electronics@siol.net http://www.secelectro.com SEC Electronics
More informationLIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More informationLIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More informationHow to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
More informationHyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
More informationUser Guide Win7Zilla
User Guide Win7Zilla Table of contents Section 1: Installation... 3 1.1 System Requirements... 3 1.2 Software Installation... 3 1.3 Uninstalling Win7Zilla software... 3 Section 2: Navigation... 4 2.1 Main
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationHydras 3 LT Quick Start
Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL
More informationManual. Danfoss Central Station Communications Software Version 3
Manual Danfoss Central Station Communications Software Version 3 RS.8A.Q1.02 1-2001 Contents Introduction 4 System Overview 4 Minimum and Recommended Hardware Requirements 4 Using the Keyboard to Select
More informationEPM110 Field Strength Measuring Instrument
EPM110 Field Strength Measuring Instrument Sensortechnik GmbH EN Data Sheet Subject to technical alteration Issue date 2009/07/08 The content of this manual is exclusively determined for your own information
More informationUser Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
More informationRGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units
I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data
More informationUser Manual WatchPower
User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationHP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written
More informationUser Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller Manual version : v1.00 Networking and MIS Manual Dryer controller Page 1 of 16 Document history Preliminary version
More informationLab Experiment 1: The LPC 2148 Education Board
Lab Experiment 1: The LPC 2148 Education Board 1 Introduction The aim of this course ECE 425L is to help you understand and utilize the functionalities of ARM7TDMI LPC2148 microcontroller. To do that,
More informationAC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
More informationPM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
More informationDUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
More informationNeo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited
Neo-Neon LED Vision Mesh Screen Operation Manual He Shan Decorative Lighting Company Limited LED Display Engineering Department 1 Contents Chapter1 Specification and Function Parameters 3 Chapeter2 Structure
More informationSA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
More informationTable Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...
Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5
More informationUser s Manual. Management Software for Inverter
WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...
More informationTCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
More informationInstruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
More informationPLC training panel (Twido version)
PLC training panel (Twido version) User manual Name School of Trades Produced by: GJR October 2012 Colour leaves: 9 BW leaves: 2 Cover colour: White Cover image: G.J.Rogerson Acknowledgments: Much of the
More informationCart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
More informationVicon Flash Upgrade Software
INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using
More informationTBS Help Index / On Board Software User Manual
TBS Help Index / On Board Software User Manual The TBS 2000 Functional Testing Systems Software has a convenient, quick and easy access on board software help manual. While a hard copy of on board TBS
More informationLEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
More informationSwitchView 1000 Switch. Installer/User Guide
SwitchView 1000 Switch Installer/User Guide SwitchView 1000 Switch Installer/User Guide Avocent, the Avocent logo, The Power of Being There and SwitchView are registered trademarks of Avocent Corporation.
More informationKeep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
More informationProductivity Software Features
O P E R A T I O N S A N D P R O C E D U R E S F O R T H E P R O D U C T I V I T Y S O F T W A R E Productivity Software Features Remote CS-230 calibration and set-up on a personal computer. CS-230 calibration
More informationUSBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual
USBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual Copyright 2007 SofTec Microsystems DC01197 We want your feedback! SofTec Microsystems is always on
More informationAsh Capture Control User Guide
Ash Capture Control User Guide Revision 1.4 Table of Contents Software Installation... 3 Hardware Installation... 6 System Block Diagram... 7 Using Ash Capture Control... 8 Launching the Application...
More informationDigital Photo Bank / Portable HDD Pan Ocean E350 User Manual
Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual Installing a hard disk 1. Power off the unit. 2. Remove the bottom cover from the unit by removing four screws. 3. Insert the 2.5 HDD to the
More informationVDPLAT1 ANIMATED RGB LED TILE USER MANUAL
ANIMATED RGB LED TILE USER MANUAL 2 ANIMATED RGB LED TILE 1. Introduction To all residents of the European Union Important environmental information about this product This symbol on the device or the
More informationConfig software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
More informationWinLIN Setup and Operation:
Frequently Asked Questions about the 07551-Series Masterflex L/S Computer-Compatible drives and about the Masterflex WinLIN Linkable Instrument Control Software (07551-70) WinLIN Setup and Operation: Will
More informationUser Guide Reflow Toaster Oven Controller
User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB
More informationPCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
More informationTP- 051 GPS RECEIVER
TP- 051 GPS RECEIVER CONTENTS 1. Overview 3 2. Features 3 3. The advantages of TP-051 GPS Receiver 4 4. The appearance and structures 4 5. Applications 5 6. Installation steps for the TP-051 GPS Receiver
More informationD-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL
1/1 D-MAX.D1 1A Manual S1 D-MAX OPERATOR INTERFACE (Application Home Screen Is Shown) D-MAX CONTROLLER 04/14/2008 2008 Fife Corporation. All rights reserved. Figure Sheet 2-249 This page is intentionally
More informationQuick Start Turning on the Tablet PC for the First Time
User s Manual DL46 Getting Started Congratulations on your purchase of a Tablet PC. The Tablet PC is a fully functional PC with built-in LAN, and wireless connectivity. With your Tablet PC you will be
More informationUser Tutorial on Changing Frame Size, Window Size, and Screen Resolution for The Original Version of The Cancer-Rates.Info/NJ Application
User Tutorial on Changing Frame Size, Window Size, and Screen Resolution for The Original Version of The Cancer-Rates.Info/NJ Application Introduction The original version of Cancer-Rates.Info/NJ, like
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationGEIGER COUNTER "Gamma Check Pro"
GEIGER COUNTER "Gamma Check Pro" OPERATING INSTRUCTIONS FOR THE SOFTWARE Item no. 1377508 VERSION 11/15 TABLE OF CONTENTS Page 1. Functions of the Software... 3 2. Software/Driver Installation... 3 3.
More informationAddendum Advanced POS Printer Drivers
Addendum Advanced POS Printer Drivers Overview With the introduction of version 4.0, The General Store now supports the use of advanced, manufacturer s printer drivers for certain point of sale printers.
More informationPacks Infotel Limited M30. ULTIMATE Operating Instructions. Version: Copyright Packs Infotel Limited 2015, all rights reserved.
Packs Infotel Limited M30 ULTIMATE Operating Instructions Version: 4 Copyright Packs Infotel Limited 2015, all rights reserved. Packs Infotel Limited Model 30 Operating Instructions Index Page 2 Page 3
More informationNX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
More informationtesto easyheat Configuration and Analysis software Instruction manual
testo easyheat Configuration and Analysis software Instruction manual en 2 General Information General Information This documentation includes important information about the features and application of
More informationUsing These Manuals. How to Use the. Software User Guide. Display examples: 1. Understanding How to Use Your Camera.
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
More informationMitsubishi Electric Q Series PLC Ladder Monitor. Operation Manual
Mitsubishi Electric Q Series PLC Ladder Monitor Operation Manual Preface Thank you for purchasing Pro-face's PLC Ladder Monitor Add-on Kit for the Mitsubishi Electric Q Series PLC. This manual ("Mitsubishi
More informationOWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
More informationMagellan All-in-one Wireless Security System
Magellan All-in-one Wireless Security System MG6250 Console Version 1.0 Menu Programming Guide Introduction The MG6250 All-in-one Wireless Console is a two-partition, 64-zone wireless console, offering
More informationSTIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
More informationPRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
More informationFondamenti su strumenti di sviluppo per microcontrollori PIC
Fondamenti su strumenti di sviluppo per microcontrollori PIC MPSIM ICE 2000 ICD 2 REAL ICE PICSTART Ad uso interno del corso Elettronica e Telecomunicazioni 1 2 MPLAB SIM /1 MPLAB SIM is a discrete-event
More informationXPanel V2. Remote Control Panel. User Manual. XILICA Audio Design
XPanel V2 Remote Control Panel User Manual XILICA Audio Design Important Safety Instructions 1. READ THESE INSTRUCTIONS All the safety and operating instructions should be read before the product is operated.
More informationXD1000 Terminal User s Guide
XD1000 Terminal User s Guide Printer compartment Holds the printer head mechanism and large capacity paper roll. Printer cover release Press button to release the printer cover and refill the paper roll.
More informationWindows XP Pro: Basics 1
NORTHWEST MISSOURI STATE UNIVERSITY ONLINE USER S GUIDE 2004 Windows XP Pro: Basics 1 Getting on the Northwest Network Getting on the Northwest network is easy with a university-provided PC, which has
More informationOmnitapps Cloud Request Version 1.0 Manual
Omnitapps Cloud Request Version 1.0 Manual rev: 1.1 1. Start here 3 2. Configure Omnirequest with a cloud account 3 2.1 Licenses 4 2.2 Systems 5 2.3 Configurations 6 2.3.1 General settings 7 2.3.2 Startpage
More informationfor DNE-K07 Reference and Installation Manual
for DNE-K07 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION...2 Specifications... 3 Navigation... 3 INSTALLATION...4 Viewing Angle... 4 Keypad Cover Clearance... 4 Mounting the Metal
More informationViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems
ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2
More informationTutorial for MPLAB Starter Kit for PIC18F
Tutorial for MPLAB Starter Kit for PIC18F 2006 Microchip Technology Incorporated. All Rights Reserved. WebSeminar Title Slide 1 Welcome to the tutorial for the MPLAB Starter Kit for PIC18F. My name is
More informationMagic Wand Portable Scanner
Magic Wand Portable Scanner PDS-ST470-VP User Manual Table of Contents 1. Key Features... 3 2. Functional Parts... 3 3. Explanation of the Status Icons... 5 4. Using the Scanner... 5 4.1. Charging up the
More informationTable of Contents. INTRODUCTION...v. How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v
Table of Contents INTRODUCTION...v How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v PC Hardware Requirements...vi Software Installation...vii Installing DataWorker
More informationIndex. ROPIX P18 Hardware... 3. ROPIX P18 Software... 12 ROPIX P18
Index ROPIX P18 Hardware... 3 I. ROPIX P18 Profile Overview... 3 II. Parameter... 5 Sending Card... 6 Receiving Card... 8 Maintenance Tools... 8 III. ROPIX P18 Installation... 9 Cabinet Assembly... 9 Controlling
More informationRogue RE-CONN Utility
Rogue RE-CONN Utility Rogue s RE-CONN software is a utility that enables remote communication with compatible Rogue devices, using a Windows-based PC and a DCV-0001 data converter. With this utility you
More informationOPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
More informationAUDITVIEW USER INSTRUCTIONS
COMBOGARDPRO AUDITVIEW USER INSTRUCTIONS The ComboGard Pro AuditView software allows the Manager to view, save, and print the audit records. The ComboGard Pro lock maintains the last 63 lock events in
More informationOPERATION & SET-UP MANUAL. 5400 Series Coin Operated Controllers. USA Market
OPERATION & SET-UP MANUAL 5400 Series Coin Operated Controllers USA Market 705 Progress Ave. Building 63 Toronto ON Canada M1H 2X1 ITC SYSTEMS 800 Fee Fee Rd. St Louis MO USA 63043 Document: 5400_USA_rev1_7.doc
More informationomega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box 1 3/29/2010 Rev.0 DOC-OMEGABB9MAN 2 Introduction FMA1600-MDB Multi-Drop Box Operating Bulletin The FMA1600-MDB Multi-Drop Box
More informationOralChroma OralChroma DataManager
OralChroma OralChroma DataManager User s Guide for Windows Version 3.5 Introduction This is a user s manual for the OralChroma DataManager. Copyright Copyright (C) 2008- ABIMEDICAL CORPORATION. All Rights
More informationVolume. EverAccess. User s Manual
Volume 1 EverAccess User s Manual FLEX Series Access Control Management Software Flex1.0 EVERFOCUS ELECTRONICS CORPORATION Flex1.0 Instruction Guide 2004 Everfocus Electronics Corp 1801 Highland Ave Duarte
More informationRack Mount LCD KVM Assembly Installer/User Guide
Rack Mount LCD KVM Assembly Installer/User Guide Japanese Notification Chinese Notification Taiwanese Notification Rack Mount LCD KVM Assembly Installer/User Guide Avocent, the Avocent logo and The Power
More informationS PT-E550W ELECTRONIC E C LABELING L SYSTEM
ELECTRONIC E C LABELING L SYSTEM S PT-E0W In order to use your P-touch labeling system safely, read the included Quick Setup Guide first. Read this guide before you start using your P-touch labeling system.
More informationHow To Set Up A Gxp280 Ip Phone On A Cell Phone On Your Computer Or Ip Phone (Siphone) On A Sim Sim Sim Or Ipro (Cell Phone) On Your Ipro Or Ipo (Cellphone) On
GXP280 Small Business IP Phone Quick Installation Guide Part Number: 9620001302A Document Version Number: 1.0 1 GXP280 IP Phone Quick Installation Guide WARNING: Please DO NOT power cycle the GXP280 when
More informationAB-Clock. Manual. Copyright 1996-2004 by GRAHL software design
Manual Contents Contents Welcome! 4 4... The AB-Clock Menu 4... AB-Clock Settings 5... Start and Exit AB-Clock 5 Start AB-Clock... 5 Exit AB-Clock... 5 Start Parameters... 6 Procedures... 6 How to... run
More informationPC Utility User s Manual
SAM4s ER-265 Series PC Utility User s Manual Version 1.0 All specifications are subject to change without notice. 2006, CRS, Inc. CRS, Inc. Limited Warranty and Disclaimers of Warranty This manual has
More informationINSTRUCTION MANUAL OVERVIEW. ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.
INSTRUCTION MANUAL ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series. OVERVIEW The digital Remote Meter displays system operating
More informationGetting Started. Table of Contents. Quick User Guide - English
Getting Started This Quick User Guide helps you get started with the IRIScan TM Anywhere Wifi. Please read this guide before operating this scanner and its software. All information is subject to change
More informationBlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product
More informationWEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
More informationUSING THE MODEL IQ 1000 INTELLICLOCK
USING THE MODEL IQ 1000 INTELLICLOCK The IQ 1000 is an advanced model of time clock with many features and benefits designed to offer you a wide range of options in how you collect your time and attendance
More informationDigital Camera. LCD Screen. Canon Power Shot A530. Features: Features:
Digital Camera Canon Power Shot A530 Features: Special Note: The cameras have been configured for 1600 x 1200 pixels with Normal resolution. This is more than adequate for all classroom projects and will
More informationZEN-SOFT01-V3. Cat.No.W386-E1-03
ZEN-SOFT01-V3 Cat.No.W386-E1-03 ZEN-SOFT01-V3 ZEN Support Software Operation Manual Revised April 2003 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator
More informationUSER GUIDE. Cisco Small Business Pro. SPA 504G IP Phone for 8x8 Virtual Office
USER GUIDE Cisco Small Business Pro SPA 504G IP Phone for 8x8 Virtual Office Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing
More informationUM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction
User manual Central Unit for Alarm System (CUAS) Evaluation Board Introduction The Central Unit for Alarm System (CUAS) Evaluation Board provides a complete reference system addressing the low- to middle-end
More informationProgramming the On-Chip Flash on a phycore-xc161 phycore-xc167
Application Note Programming the On-Chip Flash on a phycore-xc161 phycore-xc167 Application Note Edition July 2003 LAN-020e_1 Application Note Preface...1 1 Installing Infineon MemTool...2 2 Preparing
More informationENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
More informationDVR-4TL/8TL/16TL Setup Guide
Package Content DVR-4TL/8TL/16TL Setup Guide Inspect the DVR s packaging. Make sure that the DVR-4TL/8TL/16TL is packed properly. Remove all items from the box and make sure it contains the following items.
More information