Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD
|
|
- Michael Austin
- 7 years ago
- Views:
Transcription
1 RATED IN ACCORDANCE TO AHRI STANDARD
2 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 46,500 Electric Power (W) 3,550 Energy Efficiency Ratio (EER) 13.1 Integrated Energy Efficiency Ratio (IEER) 14.4 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) 230/1/ /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 1-1/2 FLA (ea) Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 4,000 Diameter (in)-pitch (deg) Quantity 2 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 15.4 Rows - Fins per Inch 4-12 Suction Line (in OD) 3 / 4 Liquid Line (in OD) 1 / 2 Optional Hot Gas Bypass (in OD) 3 Optional Hot Gas Reheat (in OD) 3 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 565 Shipping Weight (lbs) 615 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 39,000 37,400 36,000 Electric Power (W) 3,370 3,560 3,765 Total Capacity (Btu/h) 42,500 41,000 39,500 Electric Power (W) 3,380 3,575 3,780 Total Capacity (Btu/h) 46,500 44,500 43,000 Electric Power (W) 3,400 3,590 3,800 Total Capacity (Btu/h) 50,500 48,500 47,000 Electric Power (W) 3,420 3,615 3,815 Total Capacity (Btu/h) 54,500 52,500 50,500 Electric Power (W) 3,440 3,635 3,840 2
3 Data - RCA 061 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio (EER) 13.1 Integrated Energy Efficiency Ratio (IEER) 14.2 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) 230/1/ /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 1-1/2 FLA (ea) Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 4,000 Diameter (in)-pitch (deg) Quantity 2 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 15.4 Rows - Fins per Inch 4-12 Suction Line (in OD) 7 Liquid Line (in OD) 1 / 2 Optional Hot Gas Bypass (in OD) 3 Optional Hot Gas Reheat (in OD) 3 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 590 Shipping Weight (lbs) 640 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 45,000 43,000 42,000 Electric Power (W) 4,250 4,485 4,775 Total Capacity (Btu/h) 53,500 47,000 46,000 Electric Power (W) 4,355 4,530 4,785 Total Capacity (Btu/h) 55,000 51,000 50,000 Electric Power (W) 4,380 4,615 4,865 Total Capacity (Btu/h) 57,000 56,000 54,000 Electric Power (W) 4,435 4,675 4,930 Total Capacity (Btu/h) 62,000 60,000 58,000 Electric Power (W) 4,530 4,770 5,035 3
4 Data - RCA 071 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 74,500 Electric Power (W) 6,422 Energy Efficiency Ratio (EER) 11.6 Integrated Energy Efficiency Ratio (IEER) 12.7 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 1-1/2 FLA (ea) Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 4,000 Diameter (in)-pitch (deg) Quantity 2 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 15.4 Rows - Fins per Inch 4-12 Suction Line (in OD) 7 Liquid Line (in OD) 1 / 2 Optional Hot Gas Bypass (in OD) 3 Optional Hot Gas Reheat (in OD) 1 / 2 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 610 Shipping Weight (lbs) 660 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 60,200 58,000 56,000 Electric Power (W) 6,285 6,585 6,905 Total Capacity (Btu/h) 66,000 63,000 61,000 Electric Power (W) 6,415 6,720 7,045 Total Capacity (Btu/h) 71,000 69,000 66,000 Electric Power (W) 6,600 6,860 7,245 Total Capacity (Btu/h) 77,000 74,000 71,000 Electric Power (W) 6,695 7,005 7,330 Total Capacity (Btu/h) 82,000 80,000 77,000 Electric Power (W) 6,840 7,150 7,480 4
5 Data - RCA 101 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 107,500 Electric Power (W) 9,430 Energy Efficiency Ratio (EER) 11.4 Integrated Energy Efficiency Ratio (IEER) 12.8 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 1-1 FLA (ea) Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 6,200 Diameter (in)-pitch (deg) Quantity 3 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 23.1 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 1 Liquid Line (in OD) 5 Optional Hot Gas Bypass (in OD) 1 / 2 Optional Hot Gas Reheat (in OD) 5 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 825 Shipping Weight (lbs) 900 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) 35.0T Ambient Temperature ( F) Total Capacity (Btu/h) 89,000 86,000 83,000 Electric Power (W) 8,910 9,435 9,840 Total Capacity (Btu/h) 97,000 94,000 90,000 Electric Power (W) 9,130 9,515 10,075 Total Capacity (Btu/h) 105, ,000 98,000 Electric Power (W) 9,300 9,750 10,225 Total Capacity (Btu/h) 113, , ,000 Electric Power (W) 9,465 9,935 10,395 Total Capacity (Btu/h) 122, , ,000 Electric Power (W) 9,660 10,110 10,680 5
6 Data - RCA 141 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 137,100 Electric Power (W) 12,578 Energy Efficiency Ratio (EER) 10.9 Integrated Energy Efficiency Ratio (IEER) 12.2 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 1-1 FLA (ea) Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 6,200 Diameter (in)-pitch (deg) Quantity 3 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 23.1 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 3 Liquid Line (in OD) 5 Optional Hot Gas Bypass (in OD) 1 / 2 Optional Hot Gas Reheat (in OD) 5 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 900 Shipping Weight (lbs) 975 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 113, , ,000 Electric Power (W) 12,000 12,470 13,085 Total Capacity (Btu/h) 124, , ,000 Electric Power (W) 12,150 12,845 13,340 Total Capacity (Btu/h) 133, , ,000 Electric Power (W) 12,535 13,005 13,615 Total Capacity (Btu/h) 143, , ,000 Electric Power (W) 12,710 13,295 13,905 Total Capacity (Btu/h) 153, , ,000 Electric Power (W) 13,070 13,710 14,210 6
7 Data - RCA 171 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 165,900 Electric Power (W) 13,598 Energy Efficiency Ratio (EER) 12.2 Integrated Energy Efficiency Ratio (IEER) 13.6 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 2-1 FLA (ea) 3.4 / / /2.0 Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 12,400 Diameter (in)-pitch (deg) Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 30.8 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 3 Liquid Line (in OD) 7 Optional Hot Gas Bypass (in OD) 5 Optional Hot Gas Reheat (in OD) 5 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,250 Shipping Weight (lbs) 1,345 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 144, , ,000 Electric Power (W) 12,265 12,865 13,540 Total Capacity (Btu/h) 157, , ,000 Electric Power (W) 12,400 13,015 13,670 Total Capacity (Btu/h) 170, , ,000 Electric Power (W) 12,560 13,170 13,820 Total Capacity (Btu/h) 183, , ,000 Electric Power (W) 12,775 13,390 14,015 Total Capacity (Btu/h) 198, , ,000 Electric Power (W) 12,980 13,560 14,180 7
8 Data - RCA 201 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 192,000 Electric Power (W) 16,271 Energy Efficiency Ratio (EER) 11.8 Integrated Energy Efficiency Ratio (IEER) 13.2 Qty-Nominal Tons-Type Capacity Reduction Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 2-1 FLA (ea) 3.4 / / /2.0 Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 12,400 Diameter (in)-pitch (deg) Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 30.8 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 3 Liquid Line (in OD) 7 Optional Hot Gas Bypass (in OD) 5 Optional Hot Gas Reheat (in OD) 3 / 4 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,300 Shipping Weight (lbs) 1,400 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 167, , ,000 Electric Power (W) 14,500 15,230 16,020 Total Capacity (Btu/h) 182, , ,000 Electric Power (W) 14,740 15,415 16,175 Total Capacity (Btu/h) 197, , ,000 Electric Power (W) 14,955 15,665 16,355 Total Capacity (Btu/h) 213, , ,000 Electric Power (W) 15,170 15,865 16,635 Total Capacity (Btu/h) 230, , ,000 Electric Power (W) 15,390 16,100 16,850 8
9 Data - RCA 271 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 241,300 Electric Power (W) 22,343 Energy Efficiency Ratio (EER) 10.8 Integrated Energy Efficiency Ratio (IEER) 12.4 Qty-Nominal Tons-Type Capacity Reduction Tandem Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 2-1 FLA (ea) 3.4 / / /2.0 Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 12,400 Diameter (in)-pitch (deg) Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 30.8 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 5 Liquid Line (in OD) 7 Optional Hot Gas Bypass (in OD) 5 Optional Hot Gas Reheat (in OD) 7 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,400 Shipping Weight (lbs) 1,500 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 213, , ,000 Electric Power (W) 19,315 20,310 21,360 Total Capacity (Btu/h) 232, , ,000 Electric Power (W) 19,590 20,570 21,620 Total Capacity (Btu/h) 252, , ,000 Electric Power (W) 20,020 21,000 21,895 Total Capacity (Btu/h) 273, , ,000 Electric Power (W) 20,360 21,330 22,365 Total Capacity (Btu/h) 294, , ,000 Electric Power (W) 20,720 21,700 22,730 9
10 Data - RCA 361 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 288,600 Electric Power (W) 24,879 Energy Efficiency Ratio (EER) 11.6 Integrated Energy Efficiency Ratio (IEER) 12.8 Qty-Nominal Tons-Type Capacity Reduction Tandem Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 4-1 FLA (ea) 3.4 / 3.4 / 5.4 / / 1.7 / 2.7 / / 2.0 / 2.0 / 2.0 Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 28,000 Diameter (in)-pitch (deg) Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 70.0 Rows - Fins per Inch 2-14 Suction Line (in OD) 1 5 Liquid Line (in OD) 1 1 Optional Hot Gas Bypass (in OD) 7 Optional Hot Gas Reheat (in OD) 7 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,700 Shipping Weight (lbs) 1,820 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 240, , ,000 Electric Power (W) 23,635 24,700 26,050 Total Capacity (Btu/h) 260, , ,000 Electric Power (W) 24,090 25,140 26,135 Total Capacity (Btu/h) 283, , ,000 Electric Power (W) 24,410 25,485 26,620 Total Capacity (Btu/h) 306, , ,000 Electric Power (W) 24,890 26,010 27,190 Total Capacity (Btu/h) 332, , ,000 Electric Power (W) 25,085 26,360 27,570 10
11 Data - RCA 421 RATED IN ACCORDANCE TO AHRI STANDARD Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 369,700 Electric Power (W) 33,609 Energy Efficiency Ratio (EER) 11.0 Integrated Energy Efficiency Ratio (IEER) 12.2 Qty-Nominal Tons-Type Capacity Reduction Tandem Scroll 0/50/100 (HGBP) or 0/ (Digital) Electric Supply (V/Phase/Hz) /3/60 460/3/60 575/3/60 Run Load Amps (RLA) Locked Rotor Amps (LRA) Qty - Horsepower (HP) 4-1 FLA (ea) 3.4 / 3.4 / 5.4 / / 1.7 / 2.7 / / 2.0 / 2.0 / 2.0 Type Minimum Circuit Ampacity Max. Time Delay Fuse or HACR Breaker PSC Airflow (CFM) 28,000 Diameter (in)-pitch (deg) Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 70.0 Rows - Fins per Inch 2-14 Suction Line (in OD) 2 1 Liquid Line (in OD) 1 1 Optional Hot Gas Bypass (in OD) 7 Optional Hot Gas Reheat (in OD) 7 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,770 Shipping Weight (lbs) 1,900 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages Cooling Saturated Suction Temperature ( F) Ambient Temperature ( F) Total Capacity (Btu/h) 306, , ,000 Electric Power (W) 31,685 33,335 34,495 Total Capacity (Btu/h) 334, , ,000 Electric Power (W) 32,350 33,705 35,465 Total Capacity (Btu/h) 359, , ,000 Electric Power (W) 33,355 34,440 35,885 Total Capacity (Btu/h) 391, , ,000 Electric Power (W) 33,900 35,550 36,695 Total Capacity (Btu/h) 421, , ,000 Electric Power (W) 34,815 36,165 37,925 11
12 Typical Wiring Diagram Condensing Disconnect L1 L2 L3 Condensing Control Panel R Y 24VAC, Switched Compressor G Supply Fan C 24VAC, Common, Unswitched NOTES: 1. All electrical wiring and connections, including electrical grounding must comply with: a. ed States: Refer to NFPA 70- latest revision, National Electrical Code, and local ordinances. b. Canada: Refer to CSA C22.1, Part 1- latest revision, Canadian Electrical Code and local ordinances. 2. Class 1 circuit 3. Condensing unit disconnect is not provided with condensing unit as standard. Disconnect may be obtained from factory as optional equipment or provided by others. 4. Terminal Y2 is only used on dual-circuit units. Typical Split System Installation Disconnect Interconnecting Control Wiring Liquid Line Suction Line Sleeve And Flashing Condensing Optional Hot Gas Reheat Optional Hot Gas Bypass Disconnect Outside Air or Return Air Air Handler Supply Air Trap And Drain Connection NOTES: 1. Condensing unit disconnect is not provided with condensing unit as standard. Disconnect may be obtained from factory as optional equipment or provided by others. 2. Air handler, air handler disconnect, interconnecting control wiring, all refrigerant line piping and sleeve/flashing materials are by others. 3. Suction, hot gas bypass, and hot gas reheat lines should be insulated with 5/8 minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated 5/8 minimum thickness closed cell foam insulation. 12
13 Typical Installation with on Bottom Optional Hot Gas Reheat Condensate Trap And Pipe Loop To Top Of Coil Suction Liquid Optional Hot Gas Bypass Slope Down Towards Condensing NOTES: 1. To prevent oil migration, lines should slope downwards towards the condensing unit and should slope downward away from the air handler. 2. Vertical risers greater than 4' in height should have a P trap installed at the base of the air handler. 3. Vertical risers greater than 20' in height require an extra P trap for every 20' of riser height in addition to the P trap installed at the base of the air handler. The trap is inverted at the top of the vertical rise. Typical Installation with Condensing on Top Optional Hot Gas Bypass Suction Liquid Optional Hot Gas Reheat Condensate Trap And Pipe Slope Down From Air Handler NOTES: 1. To prevent oil migration, lines should slope downwards towards the condensing unit and should slope downward away from the air handler. 2. Vertical risers greater than 4' in height should have a P trap installed at the base of the air handler. 3. Vertical risers greater than 20' in height require an extra P trap for every 20' of riser height in addition to the P trap installed at the base of the air handler. The trap is inverted at the top of the vertical rise. 13
14 Dimensions - RCA 051/061/071 A TOP VIEW MULTI-DIMENSIONAL VIEW COIL B COIL CONTROLS ELECTRICAL C D Ø E SUCTION LIQUID OPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS BYPASS COMPRESSOR F Q G L M N P H A K R SIDE VIEW BACK VIEW A B C D E F G H K L M N P Q R (in)
15 Dimensions - RCA 101/141 A TOP VIEW MULTI-DIMENSIONAL VIEW COIL COIL COIL B ELECTRICAL C D ØE SUCTION LIQUID OPTIONAL HOT GAS BYPASS OPTIONAL HOT GAS REHEAT COMPRESSOR F G P N M A L K A H J Q SIDE VIEW FRONT VIEW A B C D E F G H J K L M N P Q (in)
16 Dimensions - RCA 171/201/271 TOP VIEW MULTI-DIMENSIONAL VIEW COIL A LIQUID COMPRESSOR ELECTRICAL SUCTION OPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS BYPASS B J H C G F E D SIDE VIEW A BACK VIEW A B C D E F G H J (in)
17 Dimensions - RCA 361/421 TOP VIEW MULTI-DIMENSIONAL VIEW COIL A COMPRESSOR ELECTRICAL SUCTION OPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS BYPASS LIQUID J B C G F E H D SIDE VIEW A BACK VIEW A B C D E F G H J (in)
18 Reference Information Ambient Temperature Correction Factors Ambient Temperature ( F) Total Capacity (Btu/h) Sensible Capacity (Btu/h) Electric Power (W) Recommended Refrigerant Line Sizes- Air Handler Below Condensing (in OD) 0-25 ft. Equivalent Length ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 5/8, 5/8 3/8 1/2 3/8 3/4, 3/4 1/2 1/2 3/8 48,000 3/4, 3/4 3/8 5/8 3/8 3/4, 3/4 1/2 5/8 3/8 60,000 3/4, 3/4 1/2 5/8 1/2 7/8, 7/8 1/2 5/8 1/2 72,000 7/8, 7/8 1/2 5/8 1/2 7/8, 7/8 1/2 5/8 1/2 84,000 7/8, 7/8 1/2 3/4 1/2 1-1/8, 7/8 1/2 3/4 1/2 96,000 7/8, 7/8 1/2 3/4 1/2 1-1/8, 7/8 1/2 3/4 1/2 120, /8, 7/8 1/2 3/4 5/8 1-3/8, 1-1/8 5/8 3/4 5/8 150, /8, 1-1/8 5/8 7/8 5/8 1-3/8, 1-1/8 5/8 7/8 5/8 180, /8, 1-1/8 5/8 7/8 5/8 1-3/8, 1-3/8 5/8 7/8 5/8 220, /8, 1-3/8 5/8 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 3/4 250, /8, 1-3/8 5/8 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 3/4 300, /8, 1-3/8 3/4 1-1/8 3/4 1-5/8, 1-3/8 3/4 1-1/8 3/4 360, /8, 1-5/8 3/4 1-1/8 7/8 1-5/8, 1-5/8 7/8 1-1/8 7/8 420, /8, 1-5/8 3/4 1-3/8 7/8 1-5/8, 1-5/8 7/8 1-3/8 7/ ft. Equivalent Length ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 7/8, 5/8 1/2 5/8 1/2 7/8, 3/4 1/2 5/8 N/A 48,000 7/8, 3/4 1/2 3/4 1/2 7/8, 7/8 1/2 5/8 N/A 60, /8, 3/4 1/2 3/4 1/2 7/8, 7/8 1/2 3/4 N/A 72, /8, 7/8 1/2 3/4 5/8 1-1/8, 7/8 5/8 3/4 N/A 84, /8, 7/8 5/8 7/8 5/8 1-1/8, 7/8 5/8 3/4 N/A 96, /8, 1-1/8 5/8 7/8 5/8 1-1/8, 1-1/8 5/8 3/4 N/A 120, /8, 1-1/8 5/8 7/8 3/4 1-1/8, 1-1/8 5/8 7/8 N/A 150, /8, 1-1/8 5/8 1-1/8 3/4 1-3/8, 1-1/8 3/4 7/8 N/A 180, /8, 1-3/8 3/4 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 N/A 220, /8, 1-3/8 3/4 1-1/8 7/8 1-5/8, 1-3/8 3/4 1-3/8 N/A 250, /8, 1-3/8 3/4 1-3/8 7/8 1-5/8, 1-3/8 7/8 1-3/8 N/A 300, /8, 1-3/8 7/8 1-3/8 1-1/8 2-1/8, 1-5/8 7/8 1-3/8 N/A 360, /8, 1-5/8 7/8 1-3/8 1-1/8 2-1/8, 1-5/8 1-1/8 1-3/8 N/A 420, /8, 1-5/8 1-1/8 1-3/8 1-1/8 2-1/8, 1-5/8 1-1/8 1-5/8 N/A NOTES: 1. Line sizes are calculated assuming single scroll compressors in Models and tandem scroll compressors in Models Contact the factory for any other compressor configuration. 2. All piping must comply with standard refrigeration piping techniques. Consult the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook-Refrigeration. 3. Suction, hot gas bypass and hot gas reheat lines should be insulated with a 5/8 minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated with a 5/8 minimum thickness closed cell foam insulation. 4. First suction line diameter size is for horizontal runs. Second suction line diameter size is for vertical risers. 5. Maximum suction line vertical lift is 60. Riser-sized traps are required for every 20 of vertical riser starting at the lowest point. 6. If ordered, hot gas reheat and hot gas bypass require only one line. 7. Standard hot gas bypass is not recommended for use with greater than 75 of equivalent line length. Internal hot gas bypass should be used as an alternative. 8. Contact factory for applications with digital scroll compressors. 9. Contact factory for layouts requiring more than 75 of actual line length. 18
19 Reference Information Recommended Refrigerant Line Sizes- Air Handler Level with or Above Condensing (in OD) 0-25 ft. Equivalent Length ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 5/8 3/8 1/2 3/8 3/4 3/8 1/2 3/8 48,000 3/4 3/8 5/8 3/8 7/8 1/2 5/8 3/8 60,000 3/4 1/2 5/8 1/2 7/8 1/2 5/8 1/2 72,000 7/8 1/2 5/8 1/2 1-1/8 1/2 5/8 1/2 84,000 7/8 1/2 3/4 1/2 1-1/8 5/8 3/4 1/2 96,000 7/8 1/2 3/4 1/2 1-1/8 5/8 3/4 1/2 120, /8 5/8 3/4 5/8 1-1/8 5/8 3/4 5/8 150, /8 5/8 7/8 5/8 1-3/8 3/4 7/8 5/8 180, /8 3/4 7/8 5/8 1-3/8 3/4 7/8 5/8 220, /8 3/4 1-1/8 3/4 1-3/8 7/8 1-1/8 3/4 250, /8 3/4 1-1/8 3/4 1-3/8 7/8 1-1/8 3/4 300, /8 7/8 1-1/8 3/4 1-5/8 7/8 1-1/8 3/4 360, /8 7/8 1-1/8 7/8 1-5/8 7/8 1-1/8 7/8 420, /8 1-1/8 1-3/8 7/8 1-5/8 1-1/8 1-3/8 7/ ft. Equivalent Length ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 3/4 3/8 5/8 1/2 3/4 1/2 5/8 N/A 48,000 7/8 1/2 3/4 1/2 7/8 1/2 5/8 N/A 60,000 7/8 1/2 3/4 1/2 7/8 1/2 3/4 N/A 72,000 7/8 1/2 3/4 5/8 7/8 1/2 3/4 N/A 84, /8 5/8 7/8 5/8 1-1/8 5/8 3/4 N/A 96, /8 5/8 7/8 5/8 1-1/8 5/8 3/4 N/A 120, /8 3/4 7/8 3/4 1-3/8 5/8 7/8 N/A 150, /8 3/4 1-1/8 3/4 1-3/8 3/4 7/8 N/A 180, /8 3/4 1-1/8 3/4 1-3/8 3/4 1-1/8 N/A 220, /8 7/8 1-1/8 7/8 1-5/8 3/4 1-3/8 N/A 250, /8 7/8 1-3/8 7/8 1-5/8 7/8 1-3/8 N/A 300, /8 7/8 1-3/8 1-1/8 1-5/8 7/8 1-3/8 N/A 360, /8 1-1/8 1-3/8 1-1/8 2-1/8 1-1/8 1-3/8 N/A 420, /8 1-1/8 1-3/8 1-1/8 2-1/8 1-1/8 1-5/8 N/A NOTES: 1. Line sizes are calculated assuming single scroll compressors in Models and tandem scroll compressors in Models Contact the factory for any other compressor configuration. 2. All piping must comply with standard refrigeration piping techniques. Consult the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook-Refrigeration. 3. Suction, hot gas bypass and hot gas reheat lines should be insulated with a 5/8 minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated with a 5/8 minimum thickness closed cell foam insulation. 4. Maximum suction line vertical lift is 60. Loop piping to the top of the coil. 5. Maximum liquid line vertical lift is If ordered, hot gas reheat and hot gas bypass require only one line. 7. Standard hot gas bypass is not recommended for use with greater than 75 of equivalent line length. Internal hot gas bypass should be used as an alternative. 8. Contact factory for applications with digital scroll compressors. 9. Contact factory for layouts requiring more than 75 of actual line length. 19
20 Thank you for your business! Installation Code and Annual Inspections: All installation and service of WEATHER-RITE equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Weather-Rite LLC and conform to all requirements set forth in the WEATHER-RITE manuals and all applicable governmental authorities pertaining to the installation, service, operation and labeling of the equipment. To help facilitate optimum performance and safety, Weather-Rite LLC recommends that a qualified contractor conduct, at a minimum, annual inspections of your WEATHER-RITE equipment and perform service where necessary, using only replacement parts sold and supplied by Weather-Rite LLC. Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through WEATHER-RITE representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual. There are references on this document to various trademarks. All trademarks mentioned herein, whether registered or not, are the property of their respective owners. Weather-Rite LLC is not sponsored by or affiliated with any of the trademark or registered trademark owners, and make no representations about them, their owners, their products or services. Weather-Rite LLC is not sponsored by or affiliated with BACnet or LonWorks. These products (with the exception of the CGTH and UHA[X][S] 30-75) are not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Weather-Rite LLC 616 North 5th Street Minneapolis, MN Telephone: Fax: Toll Free: Weather-Rite LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Weather-Rite LLC. Printed in the USA WRRCADSGNA 0114 Rev A
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationTWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
More informationcatalog Single Package Vertical Air Conditioners and Heat Pumps
catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................
More informationSplit System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More informationModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
More informationCOIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
More informationService Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060
4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationHIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
More informationProduct Data. Split System Cooling 22-1904-1F-EN. March 2015
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationSECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationSECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
More informationAIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency
FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationVertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
More informationCAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU
GENERAL PURPOSE (ORDINARY) LOCATION Custom Controls provides the petro-chemical and offshore industries with HVAC equipment of the highest quality and reliability on the market at an economical price.
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
More informationAIR-COOLED CONDENSERS Technical Guide
BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationINDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES
More informationSplit System Cooling Product Data
Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-12 Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant
More informationLocal Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency
More informationBasic Nameplate Information
Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationGCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationCA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:
CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living
More informationContents and Nomenclature
DX Coils Contents and Nomenclature Nomenclature... 1 Evaporator Coil Types EN... 2 EF... 2 ER... 2 EJ... 3 EK... 3 Evaporator Construction Connections... 4 Tubing... 4 Headers... 5 Tube Supports... 5 Coil
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
More informationAir-Cooled Condensers
Air-Cooled Condensers 20 to 120 Tons April 2001 Introduction Air-Cooled Condensers Built for Every Need Trane has the right condenser...if you are designing a new system or replacing an existing air-cooled
More informationSplit System Cooling Product & Performance Data
Split System Cooling Product & Performance Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1790-02-2607 (EN) Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin
More informationAluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
More informationInstallation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
More informationMINI-SPLIT REPLACEMENT PARTS
SE MINI-SPLIT REPLACEMENT PARTS The general mini-split replacement parts section is composed of the most common parts that need replacement such as sensors, capacitors, compressors, remotes for all brands.
More informationSplit System Cooling Product Data
Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy
More informationLow Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-12 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant
More informationSERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More informationDefining Quality. Building Comfort. Heating and Cooling Coils
Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.
More informationHP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
More information26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
More informationCircuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
More informationLiebert DS Thermal Management Unit
Liebert DS Thermal Management Unit System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL Economizer Coil, Dual-Cool DX with Secondary
More informationCODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping
BUILDING TECHNOLOGIES PROGRAM Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping The intent of the pipe insulation requirements is to reduce temperature changes
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationSPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES
550.46 -TG1Y (196) SPLIT-SYSTEM CONDENSING S 0 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION The HRA Series condensing unit is the outdoor part of a versatile system of air conditioning. It
More informationSERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2
SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationGreensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
More informationBring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Three Phase 4TWA3030A3000C 4TWA3030A4000C 4TWA3036A3000C 4TWA3036A4000C 4TWA3042B3000A 2½ 5 Tons 4TWA3042B4000A 4TWA3048A3000C 4TWA3048A4000C 4TWA3060B3000A 4TWA3060B4000A
More informationSubmitted to Reference Approval Construction Unit Designation Schedule #
SUBMITTAL AQV09JA High Wall 9,000 Btu/h Heat Pump Nom Cooling Capacity (Btu/h) 9,000 SEER 20.0 Cool Capacity Range (Btu/h) 3,100 to 11,900 Nom Heating Capacity (Btu/h) 11,950 HSPF 10.0 Heating COP 3.7
More informationSPLIT SYSTEMS A PRIMER. By: Thomas Legutko and Michael Taylor Carrier Corporation Syracuse, New York
SPLIT SYSTEMS A PRIMER By: Thomas Legutko and Michael Taylor Carrier Corporation Syracuse, New York September 2000 TABLE OF CONTENTS INTRODUCTION...2 SPLIT SYSTEM BASICS...3 Evaporator...3 Compressor...4
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationPRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationWON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
More informationUR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
More informationThe Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:
RFQ number PR4877728 The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs: A- Supplying and installing 30 high wall A/C split unit 3HP- 24,000
More informationLegacy Chiller Systems, Inc. www.legacychillers.com 877-988-5464
WATER-COOLED Process CHILLERS SCROLL R407C, PACKAGED, Tankless PZW1S Legacy Chiller Systems, Inc. www.legacychillers.com Example: P Z W 1 S E 5 P P = Packaged IE = Indoor Evaporator OC = Outdoor Condenser
More informationCeiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
More informationProduct Data. Features/Benefits. AquaForce 30XA080-501 Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)
Product Data AquaForce 080-501 Air-Cooled Liquid Chillers 80 to 500 Nominal Tons (265 to 1740 Nominal kw) a30-4024 Well exceeds ASHRAE 90.1 Standards. AquaForce chillers were designed from the ground up
More informationTECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
More informationPerformance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationEngineering Specifications
Engineering Specifications NORDIC W-85-H-B-*S-PD Water to Water Heat Pump Single-Stage R134a Nominal 7.5 Ton With Double Wall Condenser for Domestic Hot Water Production Maritime Geothermal Ltd. P.O. Box
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationIntroduction To VRF: System Overview, Applications, & Savings Opportunities
Introduction To VRF: System Overview, Applications, & Savings Opportunities System Overview What is VRF? Zoning System Two-Pipe / Three Pipe System Packaged DDC Control Operates as a Heat Pump Simultaneous
More informationThis permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).
CITY OF MILPITAS Building & Safety Department 455 E. Calaveras Blvd. Milpitas, CA 95035 408-586-3240 www.ci.milpitas.ca.gov RESIDENTIAL AIR CONDITIONING, REPLACEMENT 1. PERMIT INFORMATION: The replacement
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationDESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED
More information48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT
48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED
More informationCold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
More informationT-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177
T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND
More informationAppendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
More informationWATER-COOLED VERTICAL PACKAGED AIR CONDITIONERS 5-Ton through 30-Ton Capacity
9700C VPAC SERIES WATER COOLED WATER-COOLED S 5-Ton through 30-Ton Capacity RSI Company 12911 Taft Avenue, Cleveland, Ohio 44108 PH: 216-451-9300 FAX: 216-451-9376 Web: www.rsicomp.com Email: info@rsicomp.com
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More informationNordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
More informationSPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationinnovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and
More informationB. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationIt will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or damage to property. Installation
More informationCharacteristics of Evaporators
Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of
More information