SUBMITTAL SHEETS FOR 5- PLY WOOD VENEER DOORS
|
|
- Chad Barber
- 7 years ago
- Views:
Transcription
1 AMPCO ARCHITECTURAL - FLUSH WOOD DOOR SPECIFICATIONS SUBMITTAL SHEETS FOR 5- PLY WOOD DOORS Ampco Products, LLC NW 36th Avenue Miami, FL Voice: Fax: doors@ampco.com 1
2 Job Name: Submitted by: SUBMITTAL SHEETS FOR WOOD DOORS Contract/Job Number: Date: Sheet of Revisions: Date: By: Revisions: Date: By: Door Types (enter quantity required): PC Wood PC20 Wood 5 ply particle board core (AWl PC5) SLC Wood SLC20 Wood 5 ply staved lumber core (AWl SLC5) MC45 Wood 5 ply 45 minute mineral core fire door, C label (AWl FD 3/4) MC60 Wood 5 ply 60 minute mineral core fire door, B label (AWl FD 1) MC90 Wood 5 ply 90 minute mineral core fire door, B label (AWl FD 1 1/ 2) STC Wood Sound Attenuation Core (ASTM E-90-90) STC37-40MC45 Wood Sound Attenuation Mineral 45 min Fire Rated Core, C label LL Wood AF Wood 5 ply lead bonded to particle board core (AWl LL) AF20 Wood 5 ply Agrifiber core Stiles: Bonded to the core. Mill option hardwood or match to face veneer. End Rails: Bonded to the core. Mill option hardwood or structural composite lumber (SCL) Face Veneers (specify grade, cut and species): Glass Openings (specify size, location, moulding type and glass thickness): Louvers (specify size, location, louver type and if metal, specify moulding type and louver thickness): Prefit Clearances: Standard (For hinged doors: 1/8 top, 5/8 bottom, singles 1/4 width, pairs 3/ I6 width) Other (please specify): Edge Machining: Standard (For hinged doors: bevel both edges 1/8 in 2 ) Other (please specify): Packaging: Standard Other (please specify): 2
3 Quality Standards: Conforms to WDMA Industry Standard I.S.- 1A, and Architectural Woodwork Institute section 9 for type PC5, PC7 or FD 1/3, and ASTM E-152, Fire Test of Door Assemblies as performed by Warnock Hersey International. PC/PC20 Wood Veneer PARTICLE BOARD CORE AWI: PC-5, PC-7 OR FD 1/3 AMPCO ARCHITECTURAL hardwood face veneer meeting AWI or WDMA grading 1/42 face veneer prior to sanding. Running, book match to be Maximum Size: Single Door: (Unrated) 4/0 x 10/0 Single Door: (20 minute) 4/0 X 10/0 Pairs: (Unrated) 8/0 X 10/0 Pairs: (20 minute) 8/0 X 10/0 Double Egress: 8/0 X 9/0 with concealed vertical rod exit devices. Thickness: 1 3/4 or 1 3/8 (±1/16 ) Stiles: (before trim or prefit) 1 1/4 mill option kiln-dried hardwood or stiles to match face veneer species. Bonded to the core. Rails: (before trim or prefit) 1 1/4 mill option kiln-dried hardwood or structural composite lumber (SCL). Bonded to the core. Interior Blocking: In some applications the addition of optional solid wood interior blocking may be required due to fire rating and hardware specifications. Vision Panels: (20 minute) Maximum lite size for 20 minute fire rating, no more than 1296 sq in. Assembly: 5 ply or 7 ply when using 2 ply or 3 ply hardwood face veneer. Core and frame components are bonded and uniformly sanded to a thickness of 1 1/2 (±.015). For FD 1/3, core and frame components ore assembled to meet or exceed 20 minute specifications. Warranty: Lifetime from date of manufacture. For Label Authority: For FD 1/3, labeled and classified by Warnock Hersey International as a 20 minute fire/smoke barrier. Restrictions on machining and architectural accessories or application are per that authority. Core: Wood particleboard door core to meet or exceed American National Standard ANSI A208.1 for I-LD-2 Door Core. Mat-formed particleboard with density approx pounds per cubic feet (pcf) to meet or exceed Commercial Standard CS for Type 1 grade C, Class 1. Exceeds requirements for 20 minute construction authority. 3
4 Quality Standards: Conforms to WDMA Industry Standard 1.S.-1A, and Architectural Woodwork Institute section 9 for types SLC-5, SLC-7 or FD 1/3, and ASTM E-152, Fire Test of Door Assemblies as performed by Warnock Hersey International. SLC/SLC20 Wood Veneer STAVE LUMBER CORE AWI: SLC-5, SLC-7 or OR FD 1/3 AMPCO ARCHITECTURAL Assembly: 5 ply or 7 ply when using 2 ply or 3 ply hardwood face veneer. Core and frame components are bonded and uniformly sanded to a thickness of 1 1/2 (±.015). For FD 1/3, core and frame components ore assembled to meet or exceed 20 minute specifications. Maximum Size: (Neutral Pressure) Single Door: (unrated) 4/0 X 10/0 Single Door: (20 minute) 4/0 X 10/0 Pairs: (unrated) 8/0 X 10/0 Pairs: (20 minute) 8/0 X 10/0 Double egress: (20 minute) 8/0 X 9/0 with concealed vertical rod exit devices. Thickness: 1 3/4 (± 1/16 ) Stiles: (before trim or prefit) 1 1/4 mill option kiln-dried hardwood or stiles to match face veneer species. Bonded to the core. Rails: (before trim or prefit) 1 1/4 mill option kiln-dried hardwood. Bonded to the core. Interior Blocking: None required. Warranty: Lifetime from date of manufacture. For Label Authority: May be labeled and classified by Warnock Hersey International as a 20 minute fire/smoke barrier. Restrictions on machining and architectural accessories or application are per that authority. Application Exception: Exterior application of this product requires specification of Type I optional adhesives for construction of all door components including faces. This application also requires additional architectural accessories and special finishes (see Architectural Accessories Details Section V), and reduces the warranty period from lifetime to two years. Vision Panels: (20 minute) Maximum lite size for 20 minute fire rating, no more than 1296 sq in. Core: Staved lumber core with maximum 2 1/2 width low density wood blocks bonded together. Manufactured to WDMA I.S-1A sections C2 for Solid Wood Block Core. 4
5 Quality Standards: Conforms to WDMA Industry Standard 1.S.-1A, and Architectural Woodwork Institute section 9 for Type FD 3/4, ASTM E-152 fire test of door assemblies as performed by Warnock Hersey International. Maximum Size: Single Door: (unrated) 4/0 X 10/0, 4/0 X 10/0 with transom. Pairs: 8/0 X 9/0 Double egress: 8/0 X 8/0 Metal edge and astragal required for all pairs. Thickness: 1 3/4 (± 1/16 ) Stiles: (before trim or prefit) 1 1/4 mill option hardwood untreated or clear fir with a minimum density of pounds per cubic feet (pcf) or other species having equal density. Bonded to the core. Rails: (before trim or prefit) Top: 1 1/4 untreated hardwood or clear fir with a minimum of pd or other species having an equal density. Bonded to the core. Bottom: 1 1/4 hardwood with minimum of pd or other species having an equal density. Bonded to the core. MC45 Wood Veneer C LABEL 45 MINUTE FIRE DOOR AWI: FD 3/4 Assembly: 5 ply or 7 ply when using 2 ply or 3 ply hardwood face Veneer. Core and frame components are bonded per Warnock Hersey manufacturing authorities and sanded to uniform thickness of 1 1/2 (±.015). Warranty: Lifetime from date of manufacture. For Label Authority: Labeled and classified by Warnock Hersey International as a 45 minute fire barrier in sizes as described above with vision panels having aggregate areas of 1296 square inches either singularly or in multiples. Interior Blocking: In some applications the addition of optional GP Firestop composition may be required due to fire rating and hardware specifications. Core: Georgia Pacific gypsum type mineral substance with minimum density of 26 pounds per cubic foot. Faces: 1/8-2 ply or 3 ply hot pressed, cross banded 5
6 Quality Standards: Conforms to WDMA Industry Standard 1.S.-1A, and Architectural Woodwork Institute section 9 for Type FD 1, ASTM E-152 fire test of door assemblies as performed by Warnock Hersey International. MC60 Wood Veneer B LABEL 60 MINUTE FIRE DOOR AWI: FD 1 Maximum Size: Single Door: (unrated) 4/0 x 10/0, 3/0 x 10/0 with transom (3/0 x 3/0 maximum transom. Must be pre installed with transom bar of rabbet joint not used.) Pairs: 8/0 x 9/0 Double egress: 8/0 x 8/0. Double egress is larger with intumescent material. Metal edge and astragal required for all pairs. Thickness: 1 3/4 (± 1/16 ) Stiles: (before trim or prefit) 15/16 Georgia Pacific firestop composition laminated to 3/ 8 hardwood. Bonded to the core. Rails: (before trim or prefit) Top: 1 Georgia Pacific firestop composition. Bonded to core. Bottom: 1 1/2 Georgia Pacific firesfop composition. Bonded to core. Assembly: 5 ply or 7 ply when using 2 ply or 3 ply hardwood face veneer. Core and frame component are bonded per Warnock Hersey manufacturing authorities and sanded to a uniform thickness of 1 1/2 (+.015 ). Warranty: Lifetime from date of manufacture. For Label Authority: Labeled and classified by Warnock Hersey International as a 60 minute fire barrier in sizes as described above. Interior Blocking: In some applications, the addition of optional solid Georgia Pacific firestop composition may be required due to fire rating and hardware specifications. Contains no asbestos. Vision Panels: Maximum Lite size for 60 minute fire rating sq in. Core: Georgia Pacific gypsum type mineral substance with minimum density of 26 pounds per cubic foot. 6
7 Quality Standards: Conforms to WDMA Industry Standard 1.S.-1A and Architectural Woodwork Institute section 9 for type FD 1 1/2, and ASTM E-152, Fire Test of Door Assemblies as performed by Wornock Hersey International. MC90 Wood Veneer B LABEL 90 MINUTE FIRE DOOR AWI: FD 1 1/2 Maximum Size: Single Door: 4/0 x 10/0, 3/0 x 10/0 with transom (3/0 x 3/0 maximum transom). Must be installed.with steel frame transom bar. Pairs: 8/0 x 9/0. Metal edge and astragal required for all pairs. Double egress: 8/0 x 8/0 with surface vertical rod exit device or concealed vertical rods. Thickness: 1 3/4 (± 1/16 ) Stiles: (before trim or prefit) 11/8 Georgia Pacific firestop composition laminated to 3/8 hardwood. Bonded to the core. Rails: (before trim or prefit) Top: 1 firestop composition. Bonded to core. Bottom: 1 1/2 Georgia Pacific firestop composition. Bonded to core. Assembly: 5 ply or 7 ply when using 2 ply or 3 ply hardwood face veneer. Core and frame component are bonded per Warnock Hersey manufacturing authorities and sanded to a uniform thickness of 1 1/2 (+.015 ). Warranty: Lifetime from date of manufacture. For Label Authority: Labeled and classified by Warnock Hersey International as a 90 minute fire barrier in sizes as described above with vision panels having aggregate areas of 100 square inches either singularly or in multiples, or fusible link louvers having aggregate areas of 576 square inches either singularly or in multiples. Interior Blocking: In some applications the addition of optional Firestop composition may be required due to fire rating and hardware specifications. Vision Panels: Maximum Lite size for 90 minute fire rating sq in. Core: Georgia Pacific homogenous gypsum type mineral substance with minimum density of 26 pounds per cubic foot. 7
8 Quality Standards: ANSI/WDMA I.S 1-A and AWI Section 9 Quality Standards. Doors shall be clad in WDMA premium A grade wood veneer with minimum thickness 1/42 before sanding with Type 1 adhesive. Both domestic and exotic hardwood species available. Sound ratings were achieved through testing in accordance with ASTM E Maximum Size: 4/0 x 8/0 single doors only Thickness: 1-3/4 (± 1/16 ) Stile: 1-1/4 SCL Top Rail: 1-1/4 SCL Bottom Rail: 5 Interior Blocking: As required. 5 bottom rail is standard SOUND ATTENUATION STC41 AND STC42 WOOD AMPCO ARCHITECTURAL Assembly: Bonded core and frame assembly is uniformly sanded to a thickness of 1-1/2 (I.015 ) Door Features: Pairs and sets: Not Available (single flush only) Standard Bevel: 1/8 in 2 Clearances: 1/8 top, 1/8 lock and hinge stiles. See NFPA , 2007 edition, for bottom clearances. Hardware preparation: All cutouts for mortise hardware shall be made at the factory from hardware manufacturer s templates and approved shop drawing. Warranty: One year from date of manufacture. For *Doors will be shipped complete with Ampco s gasket and drop seal system. Note: Please Refer to Sealing Requirements Document. Vision Panels: Not available. Flush doors only Core: Proprietary core (HDF outer ply) using no ureaformaldehyde. Seal System Perimeter Seal Stop Bottom Rail Door Bottom Threshold STC 41 STC 42 PEMKO S-88 Gasket (black) PEMKO S-88 Gasket (black) Zero 119W Spring Weatherstrip (bronze) Zero 119W Spring Weatherstrip (bronze) Zero 564A (Mill Aluminum) 8
9 Quality Standards: ANSI/WDMA I.S 1-A and AWI Section 9 Quality Standards. Doors shall be clad in WDMA premium A grade wood veneer with minimum thickness 1/42 before sanding with Type 1 adhesive. Both domestic and exotic hardwood species available. SOUND ATTENUATION STC45 & STC46 WOOD Assembly: Bonded core and frame assembly is uniformly sanded to a thickness of 1-1/2 (I.015 ) Door Features:Pairs and sets: Not Available (single flush only) Standard Bevel: 1/8 in 2 Sound ratings were achieved through testing in accordance with ASTM E Maximum Size: 4/0 x 8/0 single doors only Thickness: 1-3/4 (± 1/16 ) Stile: 1-1/4 SCL Top Rail: 1-1/4 SCL Bottom Rail: 5 Interior Blocking: As required. 5 bottom rail is standard Clearances: 1/8 top, 1/8 lock and hinge stiles. See NFPA , 2007 edition, for bottom clearances. Hardware preparation: All cutouts for mortise hardware shall be made at the factory from hardware manufacturer s templates and approved shop drawing. Warranty: One year from date of manufacture. For *Doors will be shipped complete with Ampco s gasket and drop seal system. Vision Panels: Not available. Flush doors only Core: Proprietary core (HDF outer ply) Seal System Perimeter Seal Stop Bottom Rail Door Bottom Threshold STC 45 STC 46 Zero 119W Spring Weatherstrip (bronze) Zero 119W Spring Weatherstrip (bronze) & Zero 475 Gasket (Anod. Aluminum) PEMKO S-88 Gasket (black) Zero 369A (Anod. Aluminum) Zero 369A (Anod. Aluminum) 9
10 Quality Standards: Conforms to WDMA Industry Standard I.S.-1A, and Architectural Woodwork Institute section 9 for type FD 3/4, and ASTM E -152, Fire Test of Door Assemblies as performed by Warnock Hersey International. Maximum Size: 3/0 x 7/0 single doors only Thickness: 1-3/4 (± 1/16 ) Stile: 1 FSII Top Rail: 1-1/2 FSII Bottom Rail: 5 FSI (C LABEL 45 min door) Sound Attenuation Mineral Fire Rated Core STC37MC45,STC38MC45, STC39MC45, STC40MC45 Interior Blocking: As required. 5 FSI bottom rail is standard AMPCO ARCHITECTURAL Door Features: Pairs and sets: Not Available (single only) Standard Bevel: 1/8 in 2 Clearances: 1/8 top, 1/8 lock and hinge stiles. See NFPA , 2007 edition, for bottom clearances. Hardware preparation: All cutouts for mortise hardware shall be made at the factory from hardware manufacturer s templates and approved shop drawing. Warranty: One year from date of manufacture. For *Doors will be shipped complete with Ampco s gasket and drop seal system. Vision Panels: 100 sq. inches maximum visible area. Anemostat LoPro IS Vision Kit with 19mm (3/4 ) Pyrostop Glazing Core: Proprietary core (HDF outer ply) rules as specified. Type II bond between plys as specified. 1/42 face prior to sanding. Running, book match to be Assembly: Bonded core and frame assembly is uniformly sanded to a thickness of 1-1/2 (I.015 ) Seal System Perimeter Seal Door Bottom Threshold STC37 MC45 Zero 475 Zero 369 STC38 MC45 2 rows of NGP 5050 NGP 321V NGP950S STC39 MC45 Zero 475 and 119WB Zero 369 STC40 MC45 Zero 475 and 119WB Zero
11 Quality Standards: Conforms to WDMA Industry Standard I.S.-1A, and Arch itectural Woodwork Institute section 9 for type PC5 PC7 or FD 1/ 3, and ASTM E-152, Fire Test of Door Assemblies as performed by Warnock Hersey International. Maximum Size: Single Door: 4/0 x 8/0 Thickness: 1 3/4 (± 1/16 ) LL Wood Veneer LEAD LINED AWI: LL Warranty: Two years from date of manufacture. For Label Authority: Labeled and classified by Warnock Hersey International as a 20 minute fire /smoke barrier. Restrictions on machining and architectural accessories or application are per that authority. Stiles: (before trim or prefit) 2 mill option kiln-dried hardwood or stiles to match face veneer species. Bonded to the core. Rails: (before trim or prefit) 2 mill optian kiln-dried hardwood. Bonded to the core. Interior Blocking: Not applicable. Vision Panels: Maximum lite size 20 minute, no more than 1296 sq in. Core: 1/16-1/4 thick lead sheet, full width of care, sandwiched and bonded to particleboard and securely fastened with lead bolts. Assembly: 5 ply or 7 ply when using 2 ply or 3 ply hardwood face veneer. Core and frame compartments are bonded and uniformly sanded to a thickness of 1 1/2 (±.015). Core and frame components are assembled to meet or exceed 20 minute specifications. 11
12 Quality Standards: Conforms to WDMA Industry Standard I.S. - 1A and Architectural Woodwork Institute section 9 for FD 1/3, and ASTM E-152, Fire Test of Door Assemblies as performed by Warnock Hersey International. Maximum Size: Single Door: (unrated) 4/0 x 10/0 Single Door: (20 minute) 4/0 X 10/0 Pairs: (unrated) 8/0 X 10/0 Pairs: (20 minute) 8/0 X 10/0, 8/0 X 9/0 or 8/0 X 8/0 Double Egress: 8/0 X 9/0 with concealed vertical rod exit devices. Thickness: 1 3/4 (±1/16 ) Stiles: (before trim or prefit) 1 1/4 structural composite lumber (SCL) or 1 1/4 mill option kiln-dried hardwood. Bonded to core. Rails: (before trim or prefit) top and bottom 1¼ structural composite lumber (SCL) or 1¼ mill option kiln-dried hardwood. Bonded to core. AF/AF20 AGRIFIBER CORE AWI: AF-3 OR FD 1/3 Assembly: Bonded core and frame assembly is uniformly sanded to a thickness of 1 1/2 (+.015 ). For FD 1/3, core and frame components are assembled to meet or exceed 20 minute specifications. Warranty: Lifetime from date of manufacture. For Label Authority: For FD 1/3, may be labeled and classified by Warnock Hersey International as a 20 minute fire/smoke barrier. Restrictions on machining and architectural accessories or application are per that authority. Interior Blocking: In some applications the addition of optional solid wood interior blocking may be required due to fire rating and hardware specifications. Core: Wood Agrifiber door core to meet or exceed American National Standard ANSI A208.1 for I-LD-2 Door Core. Mat-formed Agrifiber with density approx pounds per cubic feet (pcf) to meet or exceed Commercial Standard CS for Type 1 grade C, Class 1. Exceeds requirements for 20 minute construction authority. 12
Turning nature s beauty into works of art
f l u s h d o o r s Eggers 5-ply flush doors are the very embodiment of form marrying function - extraordinary beauty and exceptional durability. We are able to produce a variety of custom architectural
More informationCore and Frame Details
and Frame Details February, 2014 Contents Architectural Flush Wood Door Codes 1-2 Performance Standards 3 GRAHAM SUPREME DOOR GSD SR 35-40 4 GSD SR 41-45 5 GSD SR 31, 33, 39, and 44 6 GSD SR 46-47 7 GRAHAM
More informationEggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
More informationBASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
More informationSubject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.
DKS Customers Interested Parties State and Local Authorities Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection. All DKS products
More informationTechnical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
More informationHMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF
More informationFF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1
FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1 Issue Date: 3/3/2009 Each furniture item scheduled in this specification manual is assigned a "key" code; each key code is crossreferenced
More informationBasic Fire Door Requirements
TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationDOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-09 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES HOLLOW METAL DOORS 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES A Division of HOLLOW METAL MANUFACTURERS A S S O C
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom
More informationSECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
More informationSECTION 062043 FIRE-RATED WOOD JAMBS
SECTION 062043 FIRE-RATED WOOD JAMBS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. [Solid wood] [Particle board] fire-rated interior door[ and sidelight] frames. 2. Intumescent/wood fire-rated interior
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationPyroguard Wired Glass
Fire-rated Glass Pyroguard Wired Glass Where glass becomes architecture Section 15 03 Introduction Oldcastle Glass stocks nonwired Pyroguard laminated safety glass and polished wired glass for commercial,
More informationA ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch
More informationArchitectural Casework 06400-01. 1.01 Description of Work
06400-01 1.01 Description of Work A. Extent of each type of architectural millwork and casework as indicated on drawings. Types of architectural casework shall include both stained and plastic laminated
More informationFire-rated Aluminum Doors
Fire-rated Aluminum Doors Langebjergvænget 13 ALUFLAM has pioneered the innovative solution to what was long considered an impossible dream (and a barrier to truly beautiful commercial architectural design),
More informationWood Sound Retardant Door Hardware Information Bulletin
overly overly 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: overly@overly.com DOOR COMPANY Wood Sound Retardant Door Hardware
More informationPhoenix-3W Series One-Way Security Revolving Doors
Phoenix-3W Series One-Way Security Revolving Doors ONE-WAY SECURITY REVOLVING DOOR SPECIFICATIONS ARCHITECTURAL SPECIFICATIONS Phoenix-3W Series One-Way Security Revolving Door Division 8 Doors and Windows
More informationAutomatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
More informationDIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
More information2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots
2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown
More informationn Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationCLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
More informationCombination & Screen Doors
Combination & Screen Doors www.bbwood.com WOOD SCREEN DOORS Removable Screens (RS) SPECIFICATIONS: Stiles and Top Rail 2-9/16 Cross Rails Bottom Rail Vertical Mull 7/8 #206 #201 58-RS 764-RS V52-RS 2 2
More informationC. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationFIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES
FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke
More informationA Complete Solution CREATING WALLS THAT DEFINE SPACE
A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.
More informationCLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationAndersen Clad Inswing Entry Doors (2001 to Present)
Andersen Clad Inswing Entry Doors (2001 to Present) What s in This Section Clad Inswing Entry Doors Page 3 Part Illustrations 3 Parts Illustration - Single Door 3 Parts Illustration - Double Door 4 Parts
More informationDelivery Split delivery Off Hr delivery Store off site To tailgate To floor Accepted by
ARCHITECTURAL WOODWORK QUALITY STANDARDS SPECCHEK INSERT MODULAR CABINETS AWI Grades Transparent Fin. Opaque Fin. Laminate clad By room By floor By item Size Width Height Thickness Construction Flush overlay
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationCasement/Awning Window Parts Reference Catalog
Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100
More informationFlexivent Windows (1952 to 1979)
Flexivent Windows (1952 to 1979) Parts Catalog Main Menu Section TOC Search What s in This Section Standard Windows................................................ Page 3 Parts Illustration...........................................................
More informationREPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012
TEST REPORT REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Fire Door Caulk LLC.
More informationAMERICAN GOTHIC PLAYHOUSE
AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus
More informationSize & Range. for windows & doors. Company
Size & Range for windows & doors A Company B General information windows and doors Sizes This catalogue contains all Airlite s standard sizes for windows and doors. These are the ones that we make every
More informationCERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
More informationDoors and frames. Technical data manual 2015 rev. 8/17/15
Doors and frames Technical data manual 2015 rev. 8/17/15 Technical data manual Main table of contents NAVIGATE VIA: A) Rollover links in each TOC (each item below is a link), B) Bookmarks on the left,
More informationAAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY
Architectural Testing AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: EAGLE WINDOW & DOOR COMPANY SERIES/MODEL: Series 01 Axiom Clad One-Piece Casement Fixed 6060 PRODUCT TYPE: Aluminum Clad Fixed
More informationFAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS
FAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS 1. What are my primary options in fire-rated glass? The glass product most often associated with fire rating is polished
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationMEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationCHECKLIST FOR DOOR HARDWARE
CHECKLIST FOR DOOR HARDWARE HINGES: Except for residential and light commercial use all hinges should be ball-bearing/oil impregnated type Hinges on exterior doors should be non-ferrous with non-removable
More informationFire-Rated Doors and Hardware. A Guide to Field Inspection
Fire-Rated Doors and Hardware A Guide to Field Inspection Foundation s Mission To promote secure and safe openings that enhance life safety Awareness To be a source of information through awareness campaign
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationVA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
More informationSECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationMIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida
Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B8049.01-401-18 Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida PRODUCT TYPE: Aluminum Storefront with Double Doors SERIES/MODEL:
More informationAssessing Curtain Walls
Assessing Curtain Walls Considerations and Best Practices Paul E Beers GCI Consultants, LLC pbeers@gciconsultants.com What is a Curtain Wall System? A curtain wall system is an outer covering of a building
More informationResidential Garage Door Terminology
A Air Infiltration: The leakage or passage of air through a door system Anodize: A hard non-corrosive oxide film on the surface of aluminum Astragal: A compressible or deformable seal provided on the bottom
More informationCONTEMPORARY - TRANSITIONAL RECEPTION STATIONS
Reception stations, the first impression expressed to visitors in your office. Transitional styling to coordinate with your other office settings, available in a selection of 16 walnut, cherry, oak, maple
More informationINSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
More informationThe replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
More information941 Key Street HPO File No. 140817 CERTIFICATE OF APPROPRIATENESS
Application Date: August 6, 2014 Applicant: Mary S Beaver, owner CERTIFICATE OF APPROPRIATENESS Property:, lot 10, block 220, East Subdivision. The property includes a historic 1,200 square foot one story
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationFabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)
Custom Blank Entrances - Applied Hardware & Preps - Tubelite Standard Hardware Butt Hinges Pivots C2 Page 1 P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) P795S
More informationFIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
More informationWhitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
More information280+ Mortise Mounted Series Shear Locks Special Application Solution
280+ Mortise Mounted Series Shear Locks Power Plus control module overcomes gaps of up to 1/4" Low Temperature Operation 280+ TRD Locknetics provides the industry s most complete selection of electromagnetic
More informationGarden Windows Builders Vinyl
TABLE OF CONTENTS Specifications... 8-2 QuickSpecGuide... 8-3 Elevations/Sizes: 1/4 Scale GardenUnits... 8-4 Grille Patterns... 8-5 SectionDetails: 6 Scale... 8-6 December 2008 JELD-WEN reserves the right
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationquality door and window systems for metal buildings
quality door and window systems for metal buildings knock-down door systems Features and Benefits: Galvanized Doors and Frames Insulated Door Cores Textured Steel Door Faces Completely Reversible (non-handed
More informationSECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: info@alpolic.com www.alpolic-northamerica.com This MANU-SPEC utilizes
More informationIntroduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
More informationHow To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
More informationRACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES
1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts
More informationMobile Home Pre-Inspection Checklist
Mobile Home Pre-Inspection Checklist TWO (2) STEP INSPECTION PROCESS STEP ONE: CALL FOR THE FIRST INSPECTION WHEN THESE ITEMS ARE COMPLETE. 1. Septic tank installed and plumbing complete. (SEE PLUMBING
More informationGypsum Board Systems Manual
CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3
More informationHolder/Release Devices with Integral Door Closers DORMA EMF/ EMR
Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR DORMA EMR Holder/Release Device with Integral Detector The DORMA EMR Series holder/release device incorporates a photoelectric detector
More informationSample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...
SECTION DIRECTORY General Information Definitions...V-CR- Design Considerations...V-CR- Composite Configurations...V-CR-4 Design Considerations and Examples for Typical Window and Door Combinations...V-CR-5
More informationThe 60 minute Fire Rated Application Explained
The 60 minute Fire Rated Application Explained One of the most confusing aspects of the code is the 60 minute fire rated application, and its easy to see why based on the questions that come up: Is 60
More informationOffice of the State Fire Marshal. Fire Rated Doors
Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow
More informationASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT Rendered to: BEKAERT SPECIALTY FILMS, LLC SERIES/MODEL: Panorama 8-mil Film PRODUCT TYPE: Fixed Window with Applied Film This
More informationInstallation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
More informationDoor Hardware Lock Specifications
Door Hardware Lock Specifications Directory Lock Type Page Exterior Mortise Lock Specifications... 2 2.5 Backset Mortise Locks Specification... 3 2.5 Backset Mortise Lock Functions (6301, 6310, 6315, 6318,
More informationHMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 830-02 METAL S & FRAMES 8d NAAMM 01 02 HARDWARE SELECTION FOR HOLLOW METAL S AND FRAMES NAAMM 01 02 8d METAL S & FRAMES A Division of HOLLOW METAL MANUFACTURERS
More informationAZEK Rail Install Guide
TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with Glass Infill... 2 Installing AZEk Rail Stairs with Glass Infill... 9 Notes...14 Please read all instructions completely
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationMRI RF SHIELDING DESIGN
MRI RF SHIELDING DESIGN Nelco s MRI RF Shielding is specifically designed for the MRI industry. Our engineers have developed a shielded enclosure made entirely of nonmagnetic materials that is unsurpassed
More information1250 & 1450 SERIES SURFACE MOUNTED CLOSERS
1250 & 1450 SERIES SURFACE MOUNTED OSERS PRODUCT SELECTION GUIDE Surface mounted 1250 & 1450 Series LCN closers feature a modern slim line design for easy installation on narrow head frames and top rails.
More informationFIRE GLASS TO GO! Fire Glass Solutions from
Fire Glass Solutions from FIRE GLASS TO GO! INTRODUCING For almost 20 years, the company now trading as CGI International has been involved in the manufacture and distribution of specialist fireresisting
More informationSun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
More informationStandard Steel Doors, Frames, Accessories and Related Components
TECHNICAL DATA SERIES S D I 111-09 Recommended Details for Standard Steel Doors, Frames, Accessories and Related Components The information that follows represents the Standard Steel Door and Frame Industry's
More informationSidelights & Transoms for A-Series Hinged Doors
Sidelights & Transoms for A-Series Hinged Doors Parts Catalog Main Menu Section TOC Search What s in This Section Sidelights & Transoms............................................. Page 3 Parts Illustration...........................................................
More informationK. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
More informationCONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE
CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise
More informationDivision 8 Doors & Windows
Division 8 Doors & Windows 08050 Basic Door and Window Materials and Methods 1. Has a minimum door leaf size of 3-0 x 7-0 been specified for both interior and exterior doors? 2. Has the door height been
More informationThe better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationMAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More information