SINGLE AND TWIN-HEAD CIRCULATORS Commercial heating & air conditioning 2 pole - 50 Hz

Size: px
Start display at page:

Download "SINGLE AND TWIN-HEAD CIRCULATORS Commercial heating & air conditioning 2 pole - 50 Hz"

Transcription

1 OPERATING LIMITS Flow rates up to: m /h* Heads up to: m Max. service pressure: bar Temperature range: - to + C Max. ambient temperature: + C ND of ports: to * m /h: with both heads operating in parallel SCX-DCX - SXM-DXM SINGLE AND TWIN-HEAD CIRCULATORS Commercial heating & air conditioning pole - Hz APPLICATIONS H m x SCX/DCX x SXM/DXM x DCX/DXM (in (in parallel) Commercial central heating in housing, office buildings, greenhouses, swimming pools, farms, etc. l Air conditioning. l Boiler recycling. l Primary loop, exchanger or heater, in secondary hot water system. All new or renovated installations. Qm /h SCX (three-phase) SXM (single-phase) DCX (three-phase) DXM (single-phase) N.T. N o -/ENG. - Ed./-

2 ADVANTAGES Versatile circulators designed for use in heating, air conditioning, and secondary hot water circuits. Dual-voltage motors, - V. Built-in thermal overload protection of motor. Redesigned casing for better performance and even quieter operation. New impeller profile for optimum efficiency. Lower energy consumption. Automatic venting of rotor chamber. DCX-DXM Standby pump available at all times. Possibility of operating the two pumps in parallel, for lower purchase and operating costs. DESIGN Pump Flanged casing, in-line ports. Bosses on rear for wall mounting. Flanges fitted with pressure gauge ports. New impeller profile. * threaded ports on model SCX -. Twin-head models (DCX-DXM) Twin pumps in a single casing. Hydraulic separation by double flap valve on discharge end. Motors pole, voltages according to European standards. Wet rotor, self-lubricating sleeve bearings. THREE-PHASE: dual voltage, speeds by plug-in selector switch coupled to voltage (except SX -, DX -, with two-speed motors) SINGLE-PHASE: speeds by plug-in selector switch, built-in capacitor. Speeds : see tables Windings -phase : -V -phase : V Frequency : Hz Protection index : IP Insulating category : F ( C) EC conformity EMC conformity - emission : EN -- - immunity : EN -- THE POLE CIRCULATOR LINES SCX SCX - DCX Single and twin-head circulators Threaded G and ND to. Three-phase, dual voltage - V motors. Voltages according to European standards. Three-speed motors by plug-in manual selector switch. Built-in thermal overload protection. single head models. twin-head models. STANDARD CONSTRUCTION Main parts Pump casing Impeller Shaft Air gap sleeve Sleeve bearings Casing gasket DCX Material Cast iron Composite material Stainless steel Stainless steel Graphite Ethylene-Propylene SXM DXM SXM - DXM Single and twin-head circulators Threaded G and ND to. Single-phase V, winding motors with built-in capacitor. Voltages according to European standards. Two-speed motors by plug-in manual selector switch. Built-in thermal overload protection. single head models. twin-head models. MIN. SUCTION PRESSURE (m w.g.) ACCORDING TO OPERATING TEMPERATURE MODEL -phase SCX DCX -phase SXM DXM C C C SX DX - SX DX NB: At high altitudes, add. m for every m. (. m w.g. = bar) IDENTIFICATION SCX: single pump, -phase DCX: twin pump, -phase ND of ports (mm) Total pressure head (dm) nominal flow SXM: single pump, -phase DXM: twin pump, -phase SCX - DCX -

3 COMPETITIVE CHANGES A B THREE-PHASE, PLE MOTOR* Dual-voltage, -phase - V With plug-in speed selector coupled to operating voltage (see opposite). Built-in thermal overload probe protects winding at all speeds by external relay. New, more attractive terminal box. Electrical connections via stuffing box, input on right or left side. Display of rotation direction of motor, speed selected, and operating voltage. New data plate with information about all electrical values of the installed circulator. Very quiet motors. For -poles motors CN and CN ranges see the specific data sheets. THREE-PHASE MOTOR TERMINAL BOX Electrical connections easy to make, on very accessible terminal blocks. Speed selected by plug-in manual selector switch coupled to the operating voltage. Examples: A: speed - Voltage V B: speed - Voltage V The speed and operating voltage are displayed on the back of the terminal box. SINGLE-PHASE, PLE MOTOR V winding. Built-in capacitor. Two-speed plug-in manual selector switch. Connections to terminal blocks easy to reach, cables enter on right or left side. Built-in thermal overload probe protects winding at all speeds by external relay. ROTOR-SHAFT The perforated shaft ensures a circulation of water that allows automatic venting and lubrication. Permanent venting of the rotor chamber, eliminating manual air bleed when starting. Continuous lubrication of the rear sleeve bearing. No more seizing of shaft. IMPELLER New profile for high efficiency, lower energy consumption and noise reduction.

4 GENERAL SELECTION GRAPHS AT MAXIMUM SPEED SCX - Single Circulator POLE - -PHASE Hz SCX SCX POLE - Hz SXM - Single Circulator POLE- -PHASE Hz SXM POLE SXM - Hz MOUNTING POSITION (B): Do not use with chilled water. (B)

5 GENERAL SELECTION GRAPHS AT MAXIMUM SPEED DCX - Twin Circulator POLE - -PHASE Hz DCX DCX POLE - Hz pumps in operation DXM - Twin Circulator POLE - -PHASE Hz DXM POLE - Hz Qm /h Qm /h pumps in operation MOUNTING POSITION (A): possible mounting, but needs periodical changeover to avoid trapped air at the high point, or connection of a bleed to the port provided for it (Ø /"). (B): Do not use with chilled water. (A) (A) (B)

6 SCX - SINGLE CIRCULATORS - POLE - THREE-PHASE Hz SCX - ND -Hz,,, SCX - ND -Hz SCX - ND -Hz SCX - ND -Hz SCX - ND -Hz SCX - ND -Hz.... SCX - ND -Hz SCX - ND -Hz

7 SCX - SINGLE CIRCULATORS - POLE - THREE-PHASE Hz SCX - ND -Hz SX ND -Hz SCX - ND -Hz SX ND -Hz SCX - ND -Hz

8 DCX - TWIN CIRCULATORS - POLE - THREE-PHASE Hz DCX - ND - Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P)... DCX - ND -Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P)

9 DCX - TWIN CIRCULATORS - POLE - THREE-PHASE Hz (P/P) (P+P) DCX - ND -Hz (P/P) (P+P) DX ND -Hz DCX - ND -Hz (P/P) (P+P) (P/P) DX ND -Hz (P+P) NB: The hydraulic curves above and on the previous page give the hydraulic characteristics for one head in operation (P or P) and for both heads in parallel (P + P). ALTERNATING OPERATION PARALLEL OPERATION P P P + P PUMP OR PUMP IN OPERATION ONE HEAD ON STANDBY ENSURES OPERATING RELIABILITY WITH NO STOPPAGE OF THE INSTALLATION Operation of the pumps programmed and switched over by control box. Parallel operation of both heads for the flowrate required, allows substantially lower purchase and operating costs. A single head in operation provides about % of the capacity the installation needs during the heating season. The maximum hydraulic performance needed is delivered by parallel operation of both heads. A control box is used for programming.

10 SXM - SINGLE CIRCULATORS - POLE - SINGLE-PHASE Hz SXM - ND -Hz,,,.... SXM - ND -Hz SXM - ND -Hz SXM - ND -Hz SXM - ND -Hz SXM - ND -Hz

11 SXM - SINGLE CIRCULATORS - POLE - SINGLE-PHASE Hz DXM - TWIN CIRCULATORS - POLE - SINGLE-PHASE Hz SXM - ND -Hz DXM - ND -Hz SXM - ND -Hz DXM - ND -Hz SXM - ND -Hz.... DXM - ND -Hz

12 DXM - TWIN CIRCULATORS - POLE - SINGLE-PHASE Hz DXM - ND -Hz DXM - ND -Hz DXM - ND -Hz DXM - ND -Hz DXM - ND -Hz

13 ELECTRICAL DATA AND DIMENSIONS - SCX - THREE-PHASE Hz L L H H Pg. P P Ø/" Ø/" pressure gauge Pg Bosses for wall mounting Y = = x M depth X Drilling of bosses on request Y n x Ø ND g c D Suction-discharge flanges PN - EN - ND D c g holes mm mm mm n x Ø x x x x * SCX -: Casing with male threading for connection by union. ORDER M O T O R P U M P REPLACEMENTS REFERENCE P speed P full load current ports L H P H L P X Y Y mass MOTOR HYDRAULIC posi- in A -phase (approx.) HEAD POUCH W tion rpm Wmin Wmax V V ND mm mm mm mm mm mm mm mm mm kg ORDER REF. ORDER REF... SCX RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.... SCX -.. RL - PHE.. SX RA - PHE SX RA - PHE

14 ELECTRICAL DATA AND DIMENSIONS - DCX - THREE-PHASE Hz L L H H Ø/" bleed Pg, P P Ø/" Pg Ø/" pressure gauge Y Bosses for wall mounting x M depth = = X Drilling of bosses on request Y n x Ø ND g c D Suction-discharge flanges PN EN - ND D c g holes mm mm mm n x Ø x x x x ORDER M O T O R P U M P REPLACEMENTS REFERENCE P speed P full load current ports L H P H L P X Y Y mass MOTOR HYDRAULIC posi- in A, -phase (approx.) HEAD POUCH W tion rpm Wmin Wmax V V ND mm mm mm mm mm mm mm mm mm kg ORDER REF. ORDER REF... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE.... DCX -.. RL - PHE DX DX RA - RA - PHE -mot. PHE -mot. PHE -mot. PHE -mot.

15 ELECTRICAL DATA AND DIMENSIONS - SXM - DXM - SINGLE-PHASE Hz L L L L SXM DXM H H H H Ø/" bleed Pg, P Pg, P Ø/" Pg Ø/" pressure gauge P Ø/" Pg P Ø/" pressure gauge Y Bosses for wall mounting Y Y = = X X x M depth Drilling of bosses on request x M depth = = Y Y n x Ø ND g n x Ø ND g c D c D Suction-discharge flanges PN - EN - ND D c g holes mm mm mm n x Ø x x x x * SXM -: Casing with " male threading for connection by union. ORDER M O T O R P U M P REPLACEMENTS REFERENCE P capa- speed P full load current ports L H P H L P X Y Y mass MOTOR HYDRAULIC citor posi- in A, -phase (approx.) HEAD POUCH W µf tion rpm Wmin Wmax V ND mm mm mm mm mm mm mm mm mm kg ORDER REF. ORDER REF. SXM - xv RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE SXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE DXM - xv.. RA - M PHE

16 PRESSURE GAUGE KIT FEATURES a) Electrical data - Three-phase V or V - Hz. - Single-phase V - Hz with built-in capacitor. - Single and three-phase motors must have a protection. - Connection to the terminal box via stuffing box, inlet on left or right. b) Installation - Direct on piping, motor shaft always horizontal. - Connection to the installation: welded, round counter-flanges (not included). Differential pressure gauge kit For single and twin-head pumps Rapid connection without welding, to ports provided on flanges. BLANK COVER KIT includes: - - or - bar glycerin bath pressure gauge, - isolating cocks, - unions and connecting tubes, - bleed. Supplied in pouch with installation instructions. ORDER REF.: PRESS KIT or PRESS KIT Optional: cover + gasket REPLACEMENT OF MOTOR HEAD AND HYDRAULIC PARTS: Supplies: bare shaft motor hydraulic pouch with: impeller + circlip motor attachment screws and Allen key mounting instructions. Order ref.: see tables on preceding pages. c) Packaging - Supplied with gaskets and bolts, without counter-flanges. d) Maintenance - Replacement of motor head and hydraulic parts (see tables for order ref.). OPTIONS & ACCESSORIES Motor protection circuit-breaker (SCX). Motor control and protection box (DCX). Speed controller box. Blank off cover (DCX). Pressure gauge kit. Welded round counter-flanges, unions. Isolating valves. Anti-vibration sleeves, etc. Blank cover with gasket for twin-head pumps If one pump fails, blanks the opening left by the removal of the hydraulic assembly and motor from the pump casing. During troubleshooting, the standby pump is started and keeps the installation in operation. type of twin-head ORDER REF. circulator BLANK COVER DCX - - DXM - COUV. DCX - - DXM - DCX - - DXM - DCX - - DXM - COUV. DCX - - DXM - DCX - - DXM - DCX - - DXM - DCX - COUV. DCX - - DXM - DCX - DX - DX COUV. bd de la République - Espace Lumière - Bât. - Chatou Cedex FRANCE Tel: + () - Fax: + () -

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm] Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1 Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Catalogue Wilo- Stratos PARA

Catalogue Wilo- Stratos PARA Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Pump Maintenance - Repair

Pump Maintenance - Repair Pump Maintenance - Repair Brian Trombly Mo Droppers Cummins Bridgeway, Gaylord, Mi The basic centrifugal pump consists of two main elements: 1. The rotating element which includes an impeller and a shaft.

More information

VAD Variable Area Desuperheaters

VAD Variable Area Desuperheaters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01 SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: sigmahra@sigmahra.cz 426

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

VAD. Variable Area Desuperheaters

VAD. Variable Area Desuperheaters Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated

More information

Rotary Twin Screw Compressors

Rotary Twin Screw Compressors www.howden.com Rotary Twin Screw Compressors For industrial refrigeration, gas processing and other industries 1 HOWDEN COMPRESSORS WORLD PIONEERS OF ROTARY TWIN SCREW COMPRESSORS HOWDEN MANUFACTURES OIL

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

EC medium pressure axial fans. The effi cient system solution.

EC medium pressure axial fans. The effi cient system solution. EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for

More information

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05 SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: sigmahra@sigmahra.cz 46.98 16.05 Applications

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

LK Electric Boiler - 4,5

LK Electric Boiler - 4,5 LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Goulds Water Technology

Goulds Water Technology APPLICATIONS Specifically designed for: Homes Farms Cottages Booster service SPECIFICATIONS Pump: Pipe connections: 1¼" NPT suction, 1" NPT discharge, 1" NPT drive (pressure) Pressure switch: AS4 preset

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE. SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

SJT / SJM / SJP Large Vertical Pumps

SJT / SJM / SJP Large Vertical Pumps SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP

More information

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415 Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

dp pumps the dynamics of water HVAC centrifugal (norm) pumps dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

No: 898501 En Revision 02 2009.08. Parts List. MINEX 8101.171 100-110 222 200-21 3

No: 898501 En Revision 02 2009.08. Parts List.  MINEX 8101.171 100-110 222 200-21 3 No: 89850 En Revision 02 2009.08 Parts List MINEX 80.7 www.grindex.com 2 3 6 3 5 00-0 7 8 9 5 6 7 20 2 22 6 8 9 0 2 3 5 20 2 22 23 23 2 25 26 27 7 8 9 50 5 52 53 5 220 22 222 200-2 3 55 56 57 28 58 59

More information

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES OPERATING LIMITS Useful volume up to : L 9 L Ambient temperature : to + C Max.fluid temperature : + C* passing blade at : mm Ø Inlet dia. : mm DN Ø Outlet dia. : / Ø Vent dia.: mm Ø Cable passage : mm

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

WATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications

WATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications Issue 3 / 214 WATER pressure PUMPS AND washdown transfer pumps Clear water pumps for domestic and commercial applications Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland: Maurice Road,

More information

Equipment Information

Equipment Information 3002A Equipment Information INDEX: DESCRIPTION AND KEY FEATURES LAYOUT NOMINAL TECHNICAL DATA CONFIGURATION Sealed Air GmbH Customer Systems Center D4 Park 4 CH-6039 Root-Längenbold Telephone: +41 (0)

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

Standard offering (pumps)

Standard offering (pumps) MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk

More information

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½ to 12 Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

TFSR & TFSK Roof Fans

TFSR & TFSK Roof Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information