1 surge arresters A surge arrester is a devicedesigned to limit transient overvoltages and to run current waves to the ground, so as to limit the amplitude of this overvoltage to a non dangerous value for the installation and electrical switchgear. a few definitions c surge arrester: device designed to limit transient atmospheric overvoltages as well as to run lightning current waves to the ground c permenant operating full withstand current (Uc): permissable r.m.s. value that can be continuously applied to the surge arrestor's terminals without affecting its operation Uc is surge arrester data. It must be higher than the system rated voltage, including variations: v for protection between active conductors and the earth: -TT: Uc 1.5 Uo -T: Uc 1.1 Uo (1.5 Uo in France) -IT: Uc euo v for protection between phases and the neutral: -TT, T, IT: Uc 1.1 Uo c residual voltage (Ures): the peak value of the voltage that appears at surge arrester terminals when a discharge current runs through them c simple system voltage (Uo): the voltage between phase and neutral c system rated voltage (Un): value of the reference voltage which designates the network c level of protection (Up): voltage that characterises the protection performance of a surge arrester at In c full discharge current (Imax): maximum peak value of the discharge current with a 8/ 20 µs wave form which the surge arrestor can withstand one time c rated discharge current (In): peak value of the discharge current with a 8/ 20 µs wave form used to designate a surge arrester c permenant operating current (Ic): current that circulates in the surge arrester, when it is supplied under permenant operating full withstand current (Uc) in the absence of a fault c common mode overvoltages (MC): overvoltages that appear between active conductors and protective conductor c differential mode overvoltages (MD): overvoltages that appear between active conductors (phase/neutral) /2 Merlin Gerin
2 PRD draw-out surge arresters PRD removable surge arresters enable the rapid replacement of damaged cartridges. Removable surge arresters with indication (PRD 65r, PRD 40r) have visualisation as well as the remote transfer of "cartridge to be replaced" information. the Uc voltage depends on: c the earthing system c the protection mode (MC/MD). common technical data for PRDs c frequency: Hz c Ic: v 1P et 3P: < 800 µa v 1P+ and 3P+: 0 µa c operation indication by means of a mechanical indicator: v white/red: cartridge replacement to be scheduled in the near future v red: cartridge must be immediately replaced c disconnection of the short-circuited surge arrester to be conducted with a circuit-breaker (refer to choice table page 92506/2) c permissible internal short-circuit current for PRD 8 and PRD 15: v 1P+, 3P and 3P+: 10 ka v 1P (230 V): 10 ka v 1P (400): 3 ka c permissible internal short-circuit current for PRD 40 and PRD 65: v 1P+, 3P and 3P+: 25 ka v 1P (230 V): 10 ka v 1P (400): 3 ka c downstream and upstream terminal connection: v 2.5 to 16 mm 2 flexible cable v 2.5 to 25 mm 2 rigid cable v 10 mm 2 flexible or rigid cable if installation with lightning conductor c operating temperature: -25 C, +60 C c storage temperature: -40 C, +70 C c protection class: v IP20 at terminals v IP40 on front panel c weight (g): v 1P: 90 v 1P+: 180 v 3P: 395 v 3P+: 460. standards c IEC class 2 test c F C 61740/95. specific technical data Each surge arrester in the range has a specific use: c Incomer end protection: v the PRD 65r is recommended for a very high risk level (highly exposed site) v PRD 40r/PRD 40 are recommended for a high risk level v the PRD 15 is recommended for a low risk level c secondary protection: v the PRD 8 ensures secondary protection of loads to be protected and is placed in a cascading configuration with surge arresters at the incomer end. PRD 65r c Imax (8/20 µs): 65 ka c In (8/20 µs): 20 ka c operating back-up indicator on front panel c remote indication contact: v electrical data: DC: 12 V, 10 ma AC: 250 V, 1 A v connection using 0.5 mm 2 to 1.5 mm 2 cable. PRD 40r/PRD 40 c Imax (8/20 µs): 40 ka c In (8/20 µs): 15 ka c the PRD 40r includes: v operating back-up indicator on front panel v remote indication contact: - electrical data: DC: 12 V, 10 ma AC: 250 V, 1 A - connection using 0.5 mm 2 to 1.5 mm 2 cable. PRD 15 c Imax (8/20 µs): 15 ka c In (8/20 µs): 5 ka. PRD 8 c Imax (8/20 µs): 8 ka c In (8/20 µs): 2 ka. spare cartridges c 40, 15, 8 ka and neutral cartridges c the C65r, C40r and C neutral r cartridges have operating back-up. auxiliaries c adaptable remote indication modules, EM/ RM (see 90159/15). Merlin Gerin 90159/3
3 PRD draw-out surge arresters (V) MC (kv) in mod. PRD 1P PRD 65r PRD 40r PRD PRD PRD (V) MC/MD (kv) in mod. PRD 1P+ PRD 65r / (1) PRD 40r / PRD / PRD / PRD / (1) Up: / =1.5 /= (V) MC (kv) in mod. PRD 3P PRD 65r PRD 40r PRD PRD PRD /4 Merlin Gerin
4 PRD draw-out surge arresters (V) MC/MD (kv) in mod. PRD 3P+ PRD 65r / (1) PRD 40r / PRD / PRD / PRD / (1) Up: / =1.5 /= type Uc (V) Up cat. no. width MC (kv) in mod. cartridges C65r C65r C40r C40r C C C C C C C neutral r C neutral Merlin Gerin 90159/5
5 PF surge arresters The PF all-contained, multiple pole surge arrester range is especially adapted to TT, T-S and IT earthing systems. PF surges arresters with indication (PF65r and PF30r) have visualisation as well as remote transfer of "cartridge to be replaced" information. common technical data c frequency: Hz c max. leakage current < 200 µa c operation indication by means of an orange indicator: v not lit: ok v flashing: surge arrester must be immediately replaced c disconnection upon thermal overload builtinto the surge arrester c disconnection of the short-circuited surge arrester to be conducted with a circuitbreaker (refer to choice table page 92506/2) c permissible internal short-circuit current for PF8 and PF15: v 1P+ and 3P+: 10 ka c permissible internal short-circuit current for PF30 and PF65: v 1P+ and 3P+: 25 ka c operating temperature: -25 C to +60 C c storage temperature: -40 C to +70 C c protection class: v IP20 at terminals v IP40 on front panel c weight (g): v 1P+: 475 v 3P+: 650. standard c F C 61740/95. specific technical data Each surge arrestor in the range has a specific use: c incomer end protection: v the PF65r is recommended for a very high risk level (highly exposed site) v PF30r/PF30 are recommended for a high risk level v the PF15 is recommended for a low risk level c secondary protection: v the PF8 ensures the secondary protection of loads to be protected and is placed in a cascading configuration with surge arrestors at the incomer end. PF65r c common mode protection: v Imax (8/20 µs): 65 ka v In (8/20 µs): 20 ka v Up: 2 kv c test button for front panel indicator c remote indication contact: v normally closed v connection using tunnel terminals 2 x 2.5 mm 2 c connection using tunnel terminals: v phase and neutral: 25 mm 2 v earth: 50 mm 2. v flexible or rigid cable 10 mm 2 if installation using lightning conductor. PF30r and PF30 c common mode protection: v Imax (8/20 µs): 30 ka v In (8/20 µs): 10 ka v Up: 1.8 kv c test button for front panel indicator c the PF30r has a built-in remote indication contact: v normally closed v connection using tunnel terminals 2 x 2.5 mm 2 c connection using tunnel terminals: v phase and neutral: 25 mm 2 v earth: 50 mm 2. v flexible or rigid cable 10 mm 2 if installation using lightning conductor. PF15 c common mode protection: v Imax (8/20 µs): 15 ka v In (8/20 µs): 5 ka v Up: 1.8 kv c differential mode protection: v Imax (8/20 µs): 8 ka v In (8/20 µs): 2 ka v Up: 1 kv c connection using tunnel terminals: v phase and neutral: 16 mm 2 v earth: 25 mm 2. v flexible or rigid calbe 10 mm 2 if installation using lightning conductor. PF8 c common mode protection: v Imax (8/20 µs): 8 ka v In (8/20 µs): 2 ka v Up: 1.5 kv c differential mode protection: v Imax (8/20 µs): 8 ka v In (8/20 µs): 2 ka v Up: 1 kv c connection using tunnel terminals: v phase and neutral: 16 mm 2 v earth: 25 mm 2. v flexible or rigid cable 10 mm 2 if installation using lightning conductor /6 Merlin Gerin
6 PF surge arresters type Un Uc (V) In cat. no. width (V) MC (ka) in mod. PF65r 1P P PF30r 1P P PF30 1P P , , type Un Uc (V) In cat. no. width (V) MC/MD (ka) in mod. PF15 1P / P / Merlin Gerin 90159/7
7 PF surge arresters type Un Uc (V) In cat. no. width (V) MC/MD (ka) in mod. PF8 1P / P / /8 Merlin Gerin
8 PE surge arresters T-C and IT earthing systems The 4 PE surge arresters are particularly adapted to earthing systems: T-C and IT. Each surge arrester in the range has a specific use: c incomer end protection: v the PE65 is recommended for a very high risk level (highly exposed site) v the PE40 is recommended for a high risk level v the PE15 is recommended for a low risk level c secondary protection: v the PE8 ensures the secondary protection of loads to be protected and is placed in a cascading configuration with the surge arresters at the incomer end. common technical data c frequency: Hz c Uc: permanent operating full withstand current: 440 V c Ic: permanent operating current: < 1 ma c disconnection of short-circuited surge arrester to be conducted with a circuitbreaker (refer to choice table page 92506/2) c permissible internal short-circuit current: 3 ka c connection using tunnel terminals: v phase, neutral and earth: 25 mm 2 rigid and 16 mm 2 flexible c min. phase/neutral/earth cross-section: v 4 mm 2 without lightning conductor v 10 mm 2 with lightning conductor c protection class: v IP20 at terminals v IP40 on front panel c operating temperature: -25 C, +60 C c storage temperature: -40 C, +70 C c weight (g): v PE8: 130 v PE15: 130 v PE40: 138 v PE65: 166. standard c F C 61740/95. specific technical data PE65 c Imax (8/20 µs): 65 ka c In (8/20 µs): 20 ka c Up: 2 kv c operation indication by means of a mechanical indicator: v white/red: surge arrester replacement to be scheduled in the near future v red: surge arrester must be immediately replaced. PE40 c Imax (8/20 µs): 40 ka c In (8/20 µs): 10 ka c Up: 1.8 kv c operation indication by means of a mechanical indicator: v red: surge arrester must be immediately replaced. PE15 c Imax (8/20 µs): 15 ka c In (8/20 µs): 5 ka c Up: 1.8 kv c operation indication by means of a mechanical indicator: v red: surge arrester must be immediately replaced. PE8 c Imax (8/20 µs): 8 ka c In (8/20 µs): 2 ka c Up: 1.5 kv c operation indication by means of a mechanical indicator: v red: surge arrester must be immediately replaced. auxiliaries c adaptable remote indication modules, EM/ RM (see 90159/15). Merlin Gerin 90159/9
9 Uc if red replace V Uc if red replace V protection PE surge arresters T-C and IT earthing systems type Un Uc (V) In cat. no. width (V) MC (ka) in mod. PE PE PE PE PE / MERI GERI multi 9 PE65 Imax 65kA (8/20) 100kA (4/10) In 20kA (8/20) Up 2 kv or MERI GERI multi 9 PE65 Imax 65kA (8/20) 100kA (4/10) In 20kA (8/20) Up 2 kv 90159/10 Merlin Gerin
10 ST surge arresters ST surge arresters are designed to protect equipment on energy networks using T-S and T-C earthing systems. They are not recommended on TT systems and are forbidden on IT systems. Each surge arrester in the range has a specific use: common technical data c frequency: Hz c Uc: 275 V c operation indication by means of a mechanical indicator: v red: surge arrester must be immediately replaced c disconnection of the short-circuited surge arrester to be conducted with a circuitbreaker (refer to choice table page 92506/2) c permissible internal short-circuit current for STD: 10 ka c permissible internal short-circuit current for STM and STH: v 1P+, 3P and 3P+: 25 ka v 1P: 10 ka c upstream and downstream terminal connection: v flexible cable: 2.5 to 16 mm 2 v rigid cable: 2.5 to 25 mm 2 v flexible or rigid cable 10 mm 2 if installation with lightning conductor c operating temperature: -25 C, +60 C c storage temperature: -40 C, +70 C c protection class: v IP20 at terminals v IP40 on front panel c weight (g): v 1P: 60 v 1P+: 106 v 3P: 220 v 3P+: 250. standard v IEC class 2 test. c incomer end protection: v the STH is recommended for a very high risk level (highly exposed site) v STMs are recommended for a high risk level c secondary protection: v the STD ensures secondary protection of loads to be protected and is placed in a cascading configuration with surge arresters at the incomer end. specific technical data STH c common mode protection: v Imax (8/20 µs): 65 ka v In (8/20 µs): 20 ka v Up: 1.5 kv. STM c common mode protection: v Imax (8/20 µs): 40 ka v In (8/20 µs): 15 ka v Up: 1.2 kv. STD c common mode protection: v Imax (8/20 µs): 10 ka v In (8/20 µs): 5 ka v Up: 1.2 kv c differential mode protection: v Imax (8/20 µs): 10 ka v In (8/20 µs): 3 ka v Up: 1 kv. auxiliaries c adaptable remote indication modules, EM/ RM (see 90159/15). (V)) MC (kv) in mod. ST 1P STH STM STD Merlin Gerin 90159/11
11 ST surge arresters (V)) MC/MD (kv) in mod. ST 1P+ STH STM STD (1) (1) Up: in MD Up = (V)) MC (kv) in mod ST 3P STH STM STD (V)) MC/MD (kv) in mod. ST 3P+ STH STM STD (1) (1) Up: in MD Up = /12 Merlin Gerin
12 16420 MERI GERI multi 9 TRC F E GB I /B MERI GERI multi 9 TRC1 I /B protection parallel connection and series connection PRC surge arresters PRC surge arresters are designed to protect equipment connected to analogue telephone networks: telephone lines, current or telephone transmitter loops (telephones, answering machines, minitels, modems, fax machines). technical data c frequency: Hz c Un: 200 V AC c maximum voltage of the signal to be transmitted: 220 V c Up: v parellel PRC: 700 V v series PRC: 300 V c Imax (8/20 µs): 10 ka c In (8/20 µs): 5 ka c pass-band: v parellel PRC: 100 MHz v series PRC: 3 MHz c rated current: v PRC series: 20 ma c withstand 50 Hz (15 min): 25 A c number of protected pairs: 1 c operation indication on the series PRC, by means of a mechanical indicator: v red: surge arrester must be immediately replaced c connection: using tunnel terminals for 0.5 to 2.5 mm 2 cable c operating temperature: -25 C, +60 C c storage temperature: -40 C, +70 C c protection class: v IP20 at terminals v IP40 on front panel c weight (g): 65. auxiliaries c adaptable remote indication modules, EM/RM (see 90159/15). type cat. no. width in mod. parellel PRC telephone network network 1 35 PRC series PRC telephone network network 1 35 PRC 246 F E GB Merlin Gerin 90159/13
13 PRI surge arresters PRI surge arresters are designed to protect sensitive equipment on digital telephone networks and automated systems (PRI V) as well as on computer or data networks (PRI 6 V). technical data c frequency: Hz c Un: v PRI V v PRI 6 V c maximum voltage of the signal to be transmitted: v PRI V: 53 V v PRI 6 V: 7 V c Up: v PRI V: 70 V v PRI 6 V: 15 V c Imax (8/20 µs): 10 ka c In (8/20 µs): 5 ka c rated current: 20 ma c max. rated current: 100 ma c withstand 50 Hz (15 min): 25 A c number of protected pairs: 1 c pass-band: v PRI V: 6 MHz v PRI 6 V: 80 MHz c operation indication by means of a mechanical indicator: v red: surge arrester must be immediately replaced c connection: using tunnel terminals for 0.5 to 2.5 mm 2 cable c operating temperature: -25 C, +60 C c storage temperature: -40 C, +70 C c protection class: v IP20 at terminals v IP40 on front panel c weight (g): 65. auxiliaries c adaptable remote indication modules, EM/ RM (see 90159/15) type tension Un In cat. no. width (V) (ka) in mod. PRI network 1 35 PRI I1 I2 load supply 90159/14 Merlin Gerin
14 EM/RM remote indication modules The adaptable EM/RM remote indication modules are made up of two optical blocks, a transmitter and a receiver. They are designed to remotely signal the transfer to back-up or the disconnection of the combined surge arrester c the EM transmitter is mounted to the left and the RM receiver to the right side of a PRD, PE, PRC, PRI, STH, STM or STD surge arrester. c the RM receiver has an output contact for the remote transfer of surge arrester disconnection information c the module can monitor up to 15 surge arrester modules (18 mm) with a limit of 270 mm. technical data c voltage rating: 230 V AC c frequency: Hz c surge arrester status indication: by means of green and red indicators on the front panel c output contact: v O/C (closed between terminals 2 and 4 if fault on surge arrester) v min. power: 6 V DC and 10 ma v max. power: 250 V AC and 5 A v insulation between contacts: 1 kv AC v insulation between the contacts and the coil: 2.5 kv AC c flexible or rigid cable connection: v up to 2.5 mm 2 c operating temperature: -20 C, +40 C c storage temperature: -40 C, +70 C c weight (g): 20. type cat. no. width in mod. remode indication module EM/RM additional information dimensions: page 90148/2 practical advice: page 92506/2 Merlin Gerin 90159/15
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationElectrical safety and protection devices
Electrical safety and protection devices RCD PROTECTION The easy, economical way to safeguard yourself when working with electricity. RCDs are specifically designed to minimise the risk of a fatal electric
More informationSurge Protection for Photovoltaic Systems
Surge Protection for Photovoltaic Systems 2 photovoltaic generator disconnection boxes Index Introduction 4 Protection of PV systems 5 Surge Protection Range for PV system 6 Surge Protection Panels for
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationElectrical auxiliaries 0 For i DPN (DPN), C60 and C120
Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationWhite paper. ABB solutions for switching and protection of low speed wind turbines
White paper ABB solutions for switching and protection of low speed wind turbines ABB solutions for switching and protection of low speed wind turbines Index 1 Introduction...2 2 Full converter configuration...4
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationThe complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationInstallation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants
Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants Introduction This document explains how to install Furse Electronic Systems s for mains power supplies: Single
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationTrip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationRedline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in
Surge rresters Surgeuard omfort functions unctions Protection of an electrical installation and all electrical and electronic devices connected to this installation against destructive surges. Such voltage
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationInstruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationCAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
More informationFixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More information15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40
Presentation ABB - OVR PLUS N1 40 ABB France Lightning Protection Group All in one product SPDs with integrated back up protection are a solution that allow to have a complete surge protection design into
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationwietap wietap Overvoltage Protection Tensions running high
wietap wietap Overvoltage Protection Tensions running high 2 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as
More informationCharge Controller CC611/CC612 Preliminary datasheet
Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for
More informationThe power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants
The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants Made for the sun, threatened by atmospheric discharges The importance of surge protective
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationHow can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationinstabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationPower supply 142. Couplers 143. Data interfaces 144. Accessories 145
KNX system units The system components are KNX devices, which assume higher-level functions, independent of the application. They guarantee the necessary infrastructure in the building, ensuring a flawless
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationSiemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring
Siemens Integrated Substation Condition Monitoring System Circuit Breaker Monitoring System Description Introduction The Circuit Breaker Monitor [CBM] is only one example of the way that the Substation
More informationCurrent and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationTWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012
TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets 17th April 2012 Session 2 Technological challenges to cope with in TWENTIES field tests
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationWiring diagrams. Compact NSX. Contents
Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationPSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationMain catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology
Main catalog System pro M compact Surge and lightning protection solutions with QuickSafe technology System pro M compact Surge and lightning protection solutions with QuickSafe technology Presentation
More informationTerminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Complete Installation Guide Product Description Product Features SJ-L-DSL is network signal extension device, which consists of remote unit and local unit. It can
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationClass I surge protection with sparkover gaps
for low-voltage supplies surge protection with sparkover gaps Lightning conductors with sparkover gap for lightning protection or equipotential bonding providing class I According to the requirements of
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationReyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
More informationRenewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More information12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting