1 Air Handlers Rheem High Efficiency Air Handler RH1T/RH2T- Series Constant Torque (ECM) Efficiencies up to 16 SEER RH1T/RH2T feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile -way convertible design for upflow, downflow, horizontal left and horizontal right applications. Factory-installed indoor coil. Sturdy cabinet construction with 1.0 inch [2. mm] of foil faced insulation for excellent sound and insulating characteristics. Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cul requirements for service disconnect. 1 1 /2 ton [. kw] through ton [17.6 kw] models are between 2 1 /2 to 7 inches [1080 to 18 mm] tall and 22 inches [9 mm] deep. All models meet or exceed 0 to 00 CFM [16 to 189 L/s] per ton at. inches [.7 kpa] of external static pressure. Enhanced airflow up to.7" external static pressure. Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing. Suitable for application in mobile homes. FORM NO. H11- REV.

2 Table of Contents TABLE OF CONTENTS Engineering Features... Number Identification... Dimensional Data...-6 Airflow Directional Data...7 Airflow Performance Data RH1T Electrical Data RH1T Airflow Performance Data RH2T Electrical Data RH2T Electrical Wiring...2 Accessories...2 Limited Warranty

3 Engineering Features Engineering Features RH1T/RH2T- Series The most compact unit design available, all standard heat air handler models only 2 1 /2 to 7 inches [1079 to 18 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [1 mm] for 1 1 /2 inch [8 mm] conduit. Front refrigerant and drain connections.

4 Number Identification R H 1 T 2 17 S T A N A A *** Option Code (see ADS-80) Blank = None Minor Series A = First Voltage A = 11/1/60 D = 80V//60 J = 208/20/1/60 Controls C = Communicating N = Non-Communicating Major Series A = First Metering Device T = TEV E = EEV P = Piston Coil Efficiency S = Standard M= Medium H = High Width 17 = 17." [1.8 mm] ( CFM) 21 = 21" [. mm] ( CFM) 2 = 2." [609.6 mm] ( CFM) Nominal Capacity 2 = 18,000 [.27 kw]-2,000 [7.0 kw] BTU/H 6 = 0,000 [8.79 kw]-6,000 [10. kw] BTU/H 8 = 2,000 [12.1 kw]-8,000 [1.06 kw] BTU/H 60 = 60,000 [17.8 kw] BTU/H Type T = Constant Torque (ECM) Stages of Air Flow 1 = Single 2 = Two Stage Product Category H = Air Handler Rheem Available s at 11V A Voltage RH1T217STANAA RH1T617STANAA RH1T621MTANAA RH1T621HTANAA RH1T821STANAA RH1T821MTANAA RH1T6021STANAA RH1T82STANAA RH1T602STANAA Available s at 208V J Voltage RH1T217STANJA RH1T617STANJA RH1T621MTANJA RH1T621HTANJA RH1T821MTANJA RH1T821STANJA RH1T82STANJA RH1T6021STANAA RH1T602STANJA RH2T221MTANJA RH2T621MTANJA RH2T82MTANJA RH2T602STANJA Available s at 80V D Voltage RH1T602STANDA

5 Unit Dimensions ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7/8 [22.2 mm], 1/2 [27.8 mm], 11/2 [0 mm] DIA. KNOCKOUTS. SUPPLY AIR 10 /16 [262 mm] NOTE: 2 CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. W Air Dimensional Data LOW VOLTAGE CONNECTION /8 [1.9 mm] AND 7/8 [22.2 mm] KNOCKOUT A Return Air Opening Dimensions Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches) /8 19 / /8 19 / /8 19 / H AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) UPFLOW/DOWNFLOW APPLICATION ONLY LIQUID LINE CONNECTION COPPER (SWEAT) 19 1 /2 [9 mm] RETURN AIR OPENING /16 [1 mm] VAPOR LINE CONNECTION COPPER (SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. HORIZONTAL ADAPTER KIT VAPOR LINE CONNECTION AUXILIARY HORIZONTAL DRAIN CONNECTION 1 /16 [11 mm] 1 /8 [10 mm] 1 /16 [76 mm] 1 /16 [8 mm] 11 /8 [29 mm] 1 1 /16 [27 mm] 1 /8 [ mm] 2 1 /16 [71 mm] 1 / [1 mm] /8 [16 mm] UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. ( ) Designates Unit with Double Coil Cabinet PRIMARY DRAIN CONNECTION AUXILIARY UPFLOW/DOWNFLOW DRAIN CONNECTION LIQUID LINE CONNECTION VERTICAL DRAIN PAN

6 Dimensional Data Unit Dimensions & Weights Refrigerant Connections [ ] Air Designates Flow Metric Conversions Unit Weight/Shipping Weight Sweat (In.) [mm] ID Unit Unit Supply CFM (Nom.) [L/s] (Lbs.) [kg] Size Width Height Duct ( ) Designates Unit with Double Coil Cabinet RH1T W In. [mm] H In. [mm] A In. [mm] Unit With Unit Dimensions Liquid & WeightsVapor Lo Hi Coil (Max. KW) 217ST /8 [9.] / [19.0] 17 1 /2 [] 2 1 /2 [1080] 16 1 /2 [06] 600 [28] 800 [78] 92/106 [2/8] 617ST /8 [9.] / [19.0] 17 1 /2 [] 2 1 /2 [1080] 16 1 /2 [06] 1000 [72] 1200 [66] 96/110 [/0] 621HT /8 [9.] 7/8 [22.2] 21 1 /2 [] 7 1 /2 [18] 19 1 /2 [9] 1000 [72] 1200 [66] 17/19 [62/68] 621MT /8 [9.] 7/8 [22.2] 21 1 /2 [] 0 1 /2 [1282] 19 1 /2 [9] 1000 [72] 1200 [66] 126/12 [7/6] 821MT /8 [9.] 7/8 [22.2] 21 1 /2 [] 7 1 /2 [18] 19 1 /2 [9] 100 [661] 1600 [7] 19/11 [6/68] 821ST /8 [9.] 7/8 [22.2] 21 1 /2 [] 0 1 /2 [1282] 19 1 /2 [9] 100 [661] 1600 [7] 128/1 [6/6] 82ST /8 [9.] 7/8 [22.2] 2 1 /2 [622] 0 1 /2 [1282] 2 1 /2 [8] 1600 [7] 12/160 [6/72] 6021ST /8 [9.] 7/8 [22.2] 21 1 /2 [] 7 1 /2 [18] 19 1 /2 [9] 1600 [7] 172 [81] 19/11 [6/68] 602ST /8 [9.] 7/8 [22.2] 2 1 /2 [622] 1 /2 [110] 2 1 /2 [8] 1800 [80] 19/176 [72/80] *Maximum dehumidification airflow. Unit Dimensions & Weights Size RH2T Refrigerant Connections Air Flow Sweat (In.) [mm] ID Unit Unit Supply CFM (Nom.) [L/s] Width Height Duct Liquid Vapor W In. [mm] H In. [mm] A In. [mm] Lo Hi Unit Weight/Shipping Weight (Lbs.) [kg] Unit With Coil (Max. KW) 221MT /8 [9.] / [19.0] 21 1 /2 [] 2 1 /2 [1080] 19 1 /2 [9] 2 [28] 700 [0] 111/126 [0/7] 621MT /8 [9.] 7/8 [22.2] 21 1 /2 [] 0 1 /2 [1282] 19 1 /2 [9] 800 [77] 100 [9] 129/1 [9/66] 82MT /8 [9.] 7/8 [22.2] 2 1 /2 [622] 1 /2 [110] 2 1 /2 [8] 100 [9] 100 [660] 128/16 [8/66] 602ST /8 [9.] 7/8 [22.2] 2 1 /2 [622] 1 /2 [110] 2 1 /2 [8] 1200 [66] 1600 [7] 161/178 [7/81] 6

7 Airflow Directional Data Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW 7

8 Airflow Performance Data Airflow Performance Airflow performance data is based on cooling performance with a coil and no filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the. [8 mm] to.7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of.1 inch [ mm] W.C. external static range. Airflow Operating Limits Cabinet Width 17 17/21 Cooling BTUH x 1,000 Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (7. CFM [18 L/s]/1,000 BTUH) (0 CFM [212 L/s]/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (. CFM [16 L/s]/1,000 BTUH) (00 CFM [189 L/s]/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (0.0 CFM [1 L/s]/1,200 BTUH) (60 CFM [170 L/s]/Ton Nominal) Maximum kw Electric Heating & Minimum Electric Heat CFM [L/s] [19] 600 [28] 0 [2] 1 87 [20] [2] 800 [78] 720 [0] [291] [1] 1000 [72] 900 [2] [8] [67] 1200 [66] 1080 [10] [97] [7] 100 [661] 1260 [9] [] [80] 1600 [7] 10 [680] [709] [80] 1600 [7] 10 [680] [709] Maximum Electric Heat Rise F [ C] 80 [26.7] 6 [17.2] 66 [18.9] 1 [10.6] 9 [9.] 0 [10] 0 [10] [911] 1800 [80] 1620 [76] [786] [12.2] 8

9 Airflow Performance Data 11V/208V/20V/60V Airflow Performance Data RH1T (Constant Torque (ECM) ) No. RH1T 217ST No Heat 217ST with 1 kw 217ST No Heat 217ST with 1 kw 617ST No 617ST with 18 kw 617ST No 617ST with 18 kw Tonnage Application 1. Ton 1. Ton 2 Ton 2 Ton 2. Ton 2. Ton Ton Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 68/8 [22/229 L/s] 68/8 [22/229 L/s] 88/697 [0/29 L/s] 68/8 [22/229 L/s] 9/108 CFM [1/12 L/s] 910/109 CFM [29/00 L/s] 110/127 CFM [/602 L/s] 110/120 CFM [21/90 L/s] Blower Size/ HP [W] CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] # of 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM 87 [9] 71 [66] 608 [287] [261] 8 [229] 2 RPM x8 Watts / HP [29] CFM 68 [22] 61 [290] 72 [270] RPM Watts CFM 81 [8] 692 [26] 89 [278] [22] 67 [220] 2 RPM x8 Watts / HP [29] CFM 808 [81] 629 [297] 8 [276] RPM Watts CFM 902 [26] 86 [99] 788 [72] 72 [0] 679 [20] RPM x8 Watts / HP [29] CFM 88 [276] 816 [8] 770 [6] RPM Watts CFM 882 [16] 827 [90] 769 [6] 72 [1] 661 [12] RPM x8 Watts / HP [29] CFM 8 [9] 791 [7] 76 [2] RPM Watts CFM 109 [16] 100 [96] 1017 [80] 977 [61] 9 [1] 2 RPM x8 Watts /2 HP [7] CFM 108 [12] 100 [91] 1001 [72] RPM Watts CFM 1068 [0] 102 [8] 992 [68] 92 [9] 910 [29] 2 RPM x8 Watts /2 HP [7] CFM 109 [00] 101 [79] 976 [61] RPM Watts CFM 1270 [99] 127 [8] 1199 [66] 116 [0] 110 [] RPM x8 Watts /2 HP [7] CFM 127 [602] 12 [87] 1211 [71] RPM Watts CFM 12 [88] 1212 [72] 117 [] 110 [8] 110 [21] RPM x8 Watts /2 HP [7] CFM 120 [90] 1219 [7] 1186 [60] RPM Watts

10 Airflow Performance Data 11V/208V/20V/60V Airflow Performance Data RH1T (Constant Torque (ECM) ) (con t.) No. RH1T 621MT No 621MT with 18 kw 621MT No 621MT with 18 kw Tonnage Application 2. Ton 2. Ton &. Ton &. Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 8/110 CFM [0/21 L/s] 828/1016 CFM [91/79 L/s] 1070/1288 CFM [0/608 L/s] 102/127 CFM [92/9 L/s] Blower Size/ HP [W] # of 1/2 HP [7] 1/2 HP [7] 1/2 HP [7] 1/2 HP [7] 2 2 CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM 107 [06] 1016 [79] 96 [] 906 [28] 8 [0] RPM Watts CFM 110 [21] 109 [00] 1000 [72] RPM Watts CFM 10 [9] 988 [66] 96 [2] 880 [1] 828 [91] RPM Watts CFM 1016 [79] 961 [] 90 [27] RPM Watts CFM 126 [97] 122 [77] 1171 [] 1112 [2] 1070 [0] RPM Watts CFM RPM 97 [608] 1012 [87] 10 [66] Watts CFM 12 [82] 119 [6] 112 [9] 108 [12] 102 [92] RPM Watts CFM 127 [9] 121 [72] 1169 [2] RPM Watts Notes: Constant Torque motor speed changes. All Constant Torque motors have speed tabs. tab 1 is for continuous fan. tab 2 (low static) and tab (high static) are for lower tonnage. tab (low static) and tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at tab, except for -82, which is set at tab. For instance, (-)H1T-HM217JA is always shipped at high static 2-ton airflow ( tab ). To change to 1.-ton airflow, move the blue wire to tab 2 or on the Constant Torque motor. The low static tab 2 (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate tab as required by the application needs. The airflow for continuous fan ( tab 1) is always set at 0% of the tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 10

11 Airflow Performance Data 11V/208V/20V/60V Airflow Performance Data RH1T (Constant Torque (ECM) ) (con t.) No. RH1T 821ST No 821ST with 20 kw 821ST No 821ST with 2 kw 82ST No 82ST with 2 kw 602ST No 602ST with 0 kw Tonnage Application. Ton. Ton Ton Ton Ton Ton Ton Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 17/17 CFM [61/68 L/s] 1297/1 CFM [612/629 L/s] 1/16 CFM [72/781 L/s] 19/161 CFM [706/762 L/s] 1/172 CFM [729/817 L/s] 10/1692 CFM [710/798 L/s] 179/190 CFM [821/899 L/s] 1699/186 CFM [802/880 L/s] Blower Size/ HP [W] # of / HP [9] / HP [9] / HP [9] / HP [9] 11x11 / HP [9] 11x11 / HP [9] 11x11 / HP [9] 11x11 / HP [9] CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM 17 [69] 12 [681] 101 [661] 17 [68] 17 [61] RPM Watts CFM 17 [68] 1 [676] 102 [662] RPM Watts CFM 1 [676] 102 [662] 161 [62] 1 [629] 1297 [612] RPM Watts CFM 1 [629] 100 [61] 1267 [98] RPM Watts CFM 166 [786] 161 [770] 1601 [76] 172 [72] 1 [72] RPM Watts CFM 16 [781] 162 [766] 16 [78] RPM Watts CFM 162 [767] 191 [71] 161 [77] 12 [72] 19 [706] RPM Watts CFM 161 [762] 18 [78] 12 [719] RPM Watts CFM 178 [82] 1669 [788] 169 [77] 199 [7] 1 [729] RPM Watts CFM 172 [817] 168 [79] 160 [769] RPM Watts CFM 1708 [806] 1629 [769] 199 [7] 19 [76] 10 [710] RPM Watts CFM 1692 [798] 16 [77] 190 [70] RPM Watts CFM 1902 [898] 1862 [879] 1809 [8] 1781 [80] 179 [821] RPM Watts CFM 190 [899] 1866 [881] 182 [86] RPM Watts CFM 1862 [879] 1822 [860] 1769 [8] 171 [822] 1699 [802] RPM Watts CFM 186 [880] 1826 [862] 1792 [86] RPM Watts

12 Airflow Performance Data 11V/208V/20V/60V Airflow Performance Data RH1T (Constant Torque (ECM) ) (con t.) No. RH1T 602ST No 602ST with 0 kw Tonnage Application & Ton & Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 117/1699 CFM [716/801 L/s] 182/1661 CFM [700/78 L/s] Blower Size/ CFM [L/s] Air Delivery/RPM/Watts (No Filter) HP [W] External Static Pressure Inches W.C. [kpa] # of 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM 170 [800] 1661 [70] 162 [770] 172 [71] 117 [91] 2 RPM x11 Watts / HP [9] CFM 1697 [801] 166 [777] 1601 [76] RPM Watts CFM 1669 [788] 162 [767] 196 [7] 17 [72] 182 [700] 2 RPM x11 Watts / HP [9] CFM 1661 [78] 1611 [760] 166 [79] RPM Watts Notes: All 208/20V PSC motors have voltage taps for 208 and 20 volts. All 208/20V PSC motors are shipped on high speed and 20 volts. If the application external static is less than 0." WC, adjust the motor speed to the low static speed as described below: Unplug the black motor wire off the relay on the control board and plug in the red motor wire. Replace the cap on the black motor wire. Voltage change (208/20V motors): Move the orange lead to transformer 208V tap from 20V tap. Replace the wire cap on 20V tap. Unplug the purple motor wire off the transformer and plug in the yellow motor wire. Replace the cap on the purple motor wire. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater - (Airflow without heater - Airflow with maximum heater) x (N kw/maximum heater kw) 12

13 Airflow Performance Data 11V/208V/20V/80V Airflow Performance Data RH1T (Constant Torque (ECM) ) (con t.) No. RH1T 621H No Heat 621H 18 Kw Heat 621H No Heat 621H 18 Kw Heat 821M No Heat 821M 20 Kw Heat 821M No Heat Nonimal Cooling Capacity Tons Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP [W] # of 1/2 HP [7] 2 dual voltage 1/2 Hp [7] 2 dual voltage 1/2 Hp [7] 2 dual voltage 1/2 Hp [7] 2 dual voltage / Hp [9] 2 dual voltage / Hp [9] 2 dual voltage / Hp [9] 2 dual voltage From Factory CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts

14 Airflow Performance Data 11V/208V/20V/80V Airflow Performance Data RH1T (Constant Torque (ECM) ) (con t.) No. RH1T 821M 20 Kw Heat 6021S No Heat 6021S 0 Kw Heat 6021S No Heat 6021S 0 Kw Heat Nonimal Cooling Capacity Tons & & Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP [W] # of / Hp [9] 2 dual voltage / Hp [9] 2 dual voltage / Hp [9] 2 dual voltage / Hp [9] 2 dual voltage / Hp [9] 2 dual voltage From Factory 2 2 CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts

15 Electrical Data Electrical Data Blower Only No Electric Heat RH1T RH1T Voltage Application Phase* Hertz HP [W] RPM s Amps. Minimum Ampacity Maximum Protector 217ST 1/ [29] ST 1/2 [7] MT/621H 208/20 1 & 60 1/2 [7] ST/821M/6021S / [9] ST/82ST / [9] ST 1/ [29] ST 1/2 [7] MT/621H /2 [7] ST/821M/6021S / [9] ST / [9] ST / [9] * Blower motors are all single phase motors. 1

16 Electrical Data Electrical Data With Electric Heat RH1T Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler RH1T 217STAN 617STAN 621HTAN/ 821MTAN/ 821STAN/ 6021STAN No. kw (208/20V) (80V) PH/HZ No. Elements kw Per Type Supply Single Multiple Amps. Ampacity Minimum Ampacity Maximum Protector RXBH-17?0J 2.2/ 1/ SINGLE 10.8/ /20 20/20 RXBH-172?0J.6/.8 1/ SINGLE 17./ /29 0/0 RXBH-172?07J./7.2 1/ SINGLE 26/0 1.6 /0 /0 RXBH-172?10J 7.2/9.6 1/ SINGLE.6/ / 0/60 RXBH-172A10C 7.2/9.6 / SINGLE 20/ / 0/ RXBH-172A1J 9./12. 1/ SINGLE.1/ /69 60/70 RXBH-172A1J.1/.2 1/ MULTIPLE CKT 1 1/ /26 2/0 RXBH-172A1J 6./8. 1/ MULTIPLE CKT 2 0.1/.7 0 8/ 0/ RXBH-17?0J 2.2/ 1/ SINGLE 10.8/ /21 20/2 RXBH-172?0J.6/.8 1/ SINGLE 17./ /1 0/ RXBH-172?07J./7.2 1/ SINGLE 26/0.1 8/ 0/ RXBH-172?10J 7.2/9.6 1/ SINGLE.6/0.1 9/6 0/60 RXBH-172A10C 7.2/9.6 / SINGLE 20/ / / RXBH-172A1J 9./12. 1/ SINGLE.1/ /71 70/80 RXBH-172A1J.1/.2 1/ MULTIPLE CKT 1 1/ /27 2/0 RXBH-172A1J 6./8. 1/ MULTIPLE CKT 2 0.1/.7 0 8/ 0/ RXBH-172A1C 10.8/1. / SINGLE 0/.6.1 /9 /0 RXBH-172A1J 10.8/1. 1/ SINGLE 1.9/ /81 70/90 RXBH-172A1J.6/.8 1/ MULTIPLE CKT 1 17./ /1 0/ RXBH-172A1J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 RXBH-172A18J 12.8/17 1/ SINGLE 61.6/ /9 90/100 RXBH-172A18J./.7 1/ MULTIPLE CKT 1 20./ / / RXBH-172A18J 8./11. 1/ MULTIPLE CKT 2 1.1/ /60 60/60 RXBH-172?0J 2.2/ 1/ SINGLE 10.8/ /21 20/2 RXBH-172?0J.6/.8 1/ SINGLE 17./ /1 0/ RXBH-172?07J./7.2 1/ SINGLE 26/0.1 8/ 0/ RXBH-172?10J 7.2/9.6 1/ SINGLE.6/0.1 9/6 0/60 RXBH-172A10C 7.2/9.6 / SINGLE 20/ / / RXBH-172A1J 9./12. 1/ SINGLE.1/ /71 70/80 RXBH-172A1J.1/.2 1/ MULTIPLE CKT 1 1/ /27 2/0 RXBH-172A1J 6./8. 1/ MULTIPLE CKT 2 0.1/.7 0 8/ 0/ RXBH-172A1C 10.8/1. / SINGLE 0/.6.1 /9 /0 RXBH-172A1J 10.8/1. 1/ SINGLE 1.9/ /81 70/90 RXBH-172A1J.6/.8 1/ MULTIPLE CKT 1 17./ /1 0/ RXBH-172A1J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger standard fuse size. J Voltage (20V) single phase air handler is designed to be used with single or three phase 20 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead. 16

17 Electrical Data Electrical Data With Electric Heat RH1T (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler RH1T 621HTAN/ 621MTAN No. kw (208/20V) (80V) PH/HZ No. Elements kw Per Type Supply Single Multiple Amps. Ampacity Minimum Ampacity Maximum Protector RXBH-172A18J 12.8/17 1/ SINGLE 61.6/ /9 90/100 RXBH-172A18J./.7 1/ MULTIPLE CKT 1 20./ / / RXBH-172A18J 8./11. 1/ MULTIPLE CKT 2 1.1/ /60 60/60 RXBH-2A20C 1./19.2 / SINGLE 0/ /6 60/70 RXBH-2A20C 7.2/9.6 / MULTIPLE CKT 1 20/ / / RXBH-2A20C 7.2/9.6 / MULTIPLE CKT 2 20/ /29 2/0 RXBH-2A20J 1./19.2 1/ SINGLE 69.2/ / /110 RXBH-2A20J 7.2/9.6 1/ MULTIPLE CKT 1.6/0.1 9/6 0/60 RXBH-2A20J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 RXBH-2A2C 18/2 / SINGLE 0/ /78 70/80 RXBH-2A2C 9/12 /60 - MULTIPLE CKT 1 2/ /2 0/ RXBH-2A2C 9/12 /60 - MULTIPLE CKT 2 2/ /7 /0 RXBH-2A2J 18/2 1/ SINGLE 86./ /10 12/10 RXBH-2A2J 6/8 1/ MULTIPLE CKT /..1 2/7 /0 RXBH-2A2J 6/8 1/ MULTIPLE CKT /. 0 7/2 0/ RXBH-2A2J 6/8 1/ MULTIPLE CKT 28.8/. 0 7/2 0/ RXBH-172?0J.6/.8 1/ SINGLE 17./ /1 0/ RXBH-172?07J./7.2 1/ SINGLE 26/0.1 8/ 0/ RXBH-172?10J 7.2/9.6 1/ SINGLE.6/0.1 9/6 0/60 RXBH-172A10C 7.2/9.6 / SINGLE 20/ / / RXBH-172A1C 10.8/1. / SINGLE 0/.6.1 /9 /0 RXBH-172A1J 10.8/1. 1/ SINGLE 1.9/ /81 70/90 RXBH-172A1J.6/.8 1/ MULTIPLE CKT 1 17./ /1 0/ RXBH-172A1J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 RXBH-172A18J 12.8/17 1/ SINGLE 61.6/ /9 90/100 RXBH-172A18J./.7 1/ MULTIPLE CKT 1 20./ / / RXBH-172A18J 8./11. 1/ MULTIPLE CKT 2 1.1/ /60 60/60 Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger standard fuse size. J Voltage (20V) single phase air handler is designed to be used with single or three phase 20 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead. 17

18 Electrical Data Electrical Data With Electric Heat RH1T (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler RH1T 82STAN/ 602STAN No. kw (208/20V) (80V) PH/HZ No. Elements kw Per Type Supply Single Multiple Amps. Ampacity Minimum Ampacity Maximum Protector RXBH-172?0J 2.2/ 1/ SINGLE 10.8/ /2 2/2 RXBH-172?0J.6/.8 1/ SINGLE 17./20 6 0/ 0/ RXBH-172?07J./7.2 1/ SINGLE 26/0 6 0/ 0/ RXBH-172?10J 7.2/9.6 1/ SINGLE.6/0 6 1/8 60/60 RXBH-172A10C 7.2/9.6 / SINGLE 20/2.1 6 /7 /0 RXBH-172A1J 9./12. 1/ SINGLE.1/ /7 70/80 RXBH-172A1J.1/.2 1/ MULTIPLE CKT 1 1/ /0 0/0 RXBH-172A1J 6./8. 1/ MULTIPLE CKT 2 0.1/.7 0 8/ 0/ RXBH-172A1C 10.8/1. / SINGLE 0/.6 6 /1 /60 RXBH-172A1J 10.8/1. 1/ SINGLE 1.9/60 6 7/8 80/90 RXBH-172A1J.6/.8 1/ MULTIPLE CKT 1 17./20 6 0/ 0/ RXBH-172A1J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 RXBH-172A18J 12.8/17 1/ SINGLE 61.6/ /97 90/100 RXBH-172A18J./.7 1/ MULTIPLE CKT 1 20./2.6 6 /8 /0 RXBH-172A18J 8./11. 1/ MULTIPLE CKT 2 1.1/ /60 60/60 RXBH-2A20C 1./19.2 / SINGLE 0/ /66 60/70 RXBH-2A20C 7.2/9.6 / MULTIPLE CKT 1 20/2.1 6 /7 /0 RXBH-2A20C 7.2/9.6 / MULTIPLE CKT 2 20/ /29 2/0 RXBH-2A20J 1./19.2 1/ SINGLE 69.2/80 6 9/ /110 RXBH-2A20J 7.2/9.6 1/ MULTIPLE CKT 1.6/0 6 1/8 60/60 RXBH-2A20J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 RXBH-2A2C 18/2 / SINGLE 0/ /80 70/80 RXBH-2A2C 9/12 /60 - MULTIPLE CKT 1 2/ / 0/ RXBH-2A2C 9/12 /60 - MULTIPLE CKT 2 2/ /7 /0 RXBH-2A2J 18/2 1/ SINGLE 86./ /1 12/10 RXBH-2A2J 6/8 1/ MULTIPLE CKT /. 6 /0 /0 RXBH-2A2J 6/8 1/ MULTIPLE CKT /. 0 7/2 0/ RXBH-2A2J 6/8 1/ MULTIPLE CKT 28.8/. 0 7/2 0/ RXBH-2A0C 21.6/28.8 / SINGLE 60/ /9 90/100 RXBH-2A0C 10.8/1. / MULTIPLE CKT 1 0/.7 6 /1 /60 RXBH-2A0C 10.8/1. / MULTIPLE CKT 2 0/.7 0 8/ 0/ RXBH-2A0J 21.6/28.8 1/ SINGLE 10.8/ /18 10/17 RXBH-2A0J 7.2/9.6 1/ MULTIPLE CKT 1.6/0 6 1/8 60/60 RXBH-2A0J 7.2/9.6 1/ MULTIPLE CKT 2.6/0 0 /0 /0 RXBH-2A0J 7.2/9.6 1/ MULTIPLE CKT.6/0 0 /0 /0 Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger standard fuse size. J Voltage (20V) single phase air handler is designed to be used with single or three phase 20 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead. 18

19 Airflow Performance Data Airflow Performance Data RH2T No. RH2T Nominal Cooling Capacity Tons From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP # of s, X-1 Wet Coil No Filter CFM Air Delivery/RPM/Watts-20 Volts External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.2] Tap 2 CFM RPM Watts MT No 2.0 Tap Tap =10/817 CFM [16/8] L/s =/91 CFM [210/8] L/s 10X8 / hp speed Tap Tap CFM RPM Watts CFM RPM Watts Tap CFM RPM Watts Tap 2 CFM RPM Watts MT With 1 kw 2.0 Tap Tap =290/797 CFM [16/76] L/s =2/91 CFM [200/9] L/s 10X8 / hp speed Tap Tap CFM RPM Watts CFM RPM Watts Tap CFM RPM Watts Notes: Constant Torque (ECM) motor speed changes. All Constant Torque (ECM) motors have speed tabs. tab 1 is for continuous fan. tab 2 (low static) and tab (high static) are for lower tonnage. tab (low static) and tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at tab, except for -82, which is set at tab. For instance, (-)H2T is always shipped at high static 2-ton airflow ( tab ). To change to 1.-ton airflow, move the blue wire to tab 2 or on the Constant Torque (ECM) motor. The low static tab 2 (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate tab as required by the application needs. The airflow for continuous fan ( tab 1) is always set at 0% of the tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 19

20 Airflow Performance Data Airflow Performance Data RH2T No. RH2T Nominal Cooling Capacity Tons From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP # of s, X-1 Wet Coil No Filter CFM Air Delivery/RPM/Watts-20 Volts External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.2] Tap 2 CFM RPM Watts MT No.0 Tap Tap =/100 CFM [20/7] L/s =70/128 CFM [1/626] L/s 10X10 / Hp speed Tap Tap CFM RPM Watts CFM RPM Watts Tap CFM RPM Watts Tap 2 CFM RPM Watts MT With 18 kw.0 Tap Tap =0/97 CFM [190/60] L/s =67/1298 CFM [17/612] L/s 10X10 / Hp speed Tap Tap CFM RPM Watts CFM RPM Watts Tap CFM RPM Watts Notes: Constant Torque (ECM) motor speed changes. All Constant Torque (ECM) motors have speed tabs. tab 1 is for continuous fan. tab 2 (low static) and tab (high static) are for lower tonnage. tab (low static) and tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at tab, except for -82, which is set at tab. For instance, (-)H2T is always shipped at high static 2-ton airflow ( tab ). To change to 1.-ton airflow, move the blue wire to tab 2 or on the Constant Torque (ECM) motor. The low static tab 2 (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate tab as required by the application needs. The airflow for continuous fan ( tab 1) is always set at 0% of the tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 20

21 Airflow Performance Data Airflow Performance Data RH2T No. RH2T Nominal Cooling Capacity Tons From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP # of s, X-1 Wet Coil No Filter CFM Air Delivery/RPM/Watts-20 Volts External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.2] Tap 2 CFM RPM Watts MT No.0 Tap Tap =702/1271 CFM [1/99] L/s =992/167 CFM [68/789] L/s 11X11 / hp speed Tap Tap CFM RPM Watts CFM RPM Watts Tap CFM RPM Watts Tap 2 CFM RPM Watts MT With 2 kw.0 Tap Tap =672/121 CFM [1/82] L/s =962/16 CFM [1/772] L/s 11X11 / hp speed Tap Tap CFM RPM Watts CFM RPM Watts Tap CFM RPM Watts Notes: Constant Torque (ECM) motor speed changes. All Constant Torque (ECM) motors have speed tabs. tab 1 is for continuous fan. tab 2 (low static) and tab (high static) are for lower tonnage. tab (low static) and tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at tab, except for -82, which is set at tab. For instance, (-)H2T is always shipped at high static 2-ton airflow ( tab ). To change to 1.-ton airflow, move the blue wire to tab 2 or on the Constant Torque (ECM) motor. The low static tab 2 (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate tab as required by the application needs. The airflow for continuous fan ( tab 1) is always set at 0% of the tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 21

22 Airflow Performance Data Airflow Performance Data RH2T No. RH2T Nominal Cooling Capacity Tons From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 602ST No.0 Tap Tap =78/10 CFM [70/67] L/s =129/18 CFM [89/870] L/s 602ST With 0 kw.0 Tap Tap =7/110 CFM [/620] L/s =1209/180 CFM [70/81] L/s Blower Size/ HP # of s 11X11 / hp speed 11X11 / hp speed, Tap 2 Tap Tap Tap Tap 2 Tap Tap Tap X-1 Wet Coil No Filter CFM Air Delivery/RPM/Watts-20 Volts External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0. [.07] 0. [.10] 0. [.12] 0.6 [.1] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.2] CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts

23 Electrical Data Electrical Data Blower Only No Electric Heat RH2T RH2T Voltage Phase* Hertz HP RPM s Amps. Minimum Ampacity 221MT 1/ MT 208/20 1 & 60 / ST/82MT / * Blower motors are all single phase motors. Maximum Protector Electrical Data With Electric Heat Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler RH2T 221MT 621MT No. kw (208/20V) (80V) Ph/Hz No. Elements - kw Per Type Supply Single Multiple Amps. Ampacity Minimum Ampacity Maximum Protector RXBH-172?0J 2.2/.0 1/ SINGLE 10.8/ /18 20/20 RXBH-172?0J.6/.8 1/ SINGLE 17./ /27 2/0 RXBH-172?07J./7.2 1/ SINGLE 26.0/ /0 /0 RXBH-172?10J 7.2/9.6 1/ SINGLE.6/ /2 0/60 RXBH-172A1J 9./12. 1/ SINGLE.1/ /68 60/70.1/.2 1/ MULTIPLE CKT 1 1.0/ /2 2/2 RXBH-172A1J 6./8. 1/ MULTIPLE CKT 2 0.1/.7 0 8/ 0/ RXBH-172A10C 7.2/9.6 / SINGLE 20.0/ /1 0/ RXBH-172?0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-172?07J./7.2 1/ SINGLE 26.0/ / 0/ RXBH-172?10J 7.2/9.6 1/ SINGLE.6/ / 0/60 RXBH-172A1J 10.8/1. 1/ SINGLE 1.9/ /80 70/80.6/.8 1/ MULTIPLE CKT 1 17./ /0 0/0 RXBH-172A1J 7.2/9.6 1/ MULTIPLE CKT 2.6/ /0 /0 RXBH-172A18J 12.8/17.0 1/ SINGLE /9 90/100 RXBH-172A18J 6./8. 1/ MULTIPLE CKT 1 0.8/..8 /9 /0 6./8. 1/ MULTIPLE CKT 2 0.8/ / 0/ RXBH-172A10C 7.2/9.6 / SINGLE 20.0/ / 0/ RXBH-172A1C 10.8/1. / SINGLE 0.0/.6.8 /8 /0 RXBH-172B0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-172B07J./7.2 1/ SINGLE 26.0/ / 0/ RXBH-172B10J 7.2/9.6 1/ SINGLE.6/ / 60/60? Kit Connection Type A = Breaker B = Terminal Block C = Pullout Disconnect ➀ D Voltage = 80 Volts. *Values only. No single point kit available. NOTES: Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. If non-standard fuse size is specified, use next size larger standard fuse size. Largest motor load is included in single circuit or circuit 1 of multiple circuits. loads are balanced on phase models with or 6 heaters only. No electrical heating elements are permitted to be used with A voltage (11V) air handler. J voltage (208/20V) single phase air handler is designed to be used with single or three phase 208/20V volt electric heaters. In the case of connecting phase power to air handler terminal block without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead. Do not use 80V electrical heaters on 208/20V air handlers. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A21 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. 2

24 Electrical Data Electrical Data With Electric Heat RH2T Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler RH2T 82MT/ 602ST No. kw (208/20V) (80V) Ph/Hz No. Elements - kw Per Type Supply Single Multiple Amps. Ampacity Minimum Ampacity Maximum Protector RXBH-172?07J./7.2 1/ SINGLE 26.0/ / 0/ RXBH-172?10J 7.2/9.6 1/ SINGLE.6/ /6 0/60 RXBH-172A1J 10.8/1. 1/ SINGLE 1.9/ /81 80/90.6/.8 1/ MULTIPLE CKT 1 17./ /1 0/ RXBH-172A1J 7.2/9.6 1/ MULTIPLE CKT 2.6/0.0 0 /0 /0 RXBH-172A18J 12.8/17 1/ SINGLE 61.8/ /9 90/100 6./8. 1/ MULTIPLE CKT 1 0.8/..6 /0 /0 RXBH-172A18J 6./8. 1/ MULTIPLE CKT 2 0.8/. 0 9/ 0/ RXBH-2A20J 1./19.2 1/ SINGLE 69.2/80.6 9/ / /9.6 1/ MULTIPLE CKT 1.6/ /6 0/60 RXBH-2A20J 7.2/9.6 1/ MULTIPLE CKT 2.6/0.0 0 /0 /0 RXBH-2A2J 18.0/2.0 1/ SINGLE 86./ /11 12/10 RXBH-2A2J RXBH-2A0J (-ton only) 6.0/8.0 1/ MULTIPLE CKT /..6 2/8 /0 6.0/8.0 1/ MULTIPLE CKT /. 0 6/2 0/ 6.0/8.0 1/ MULTIPLE CKT 28.8/. 0 6/2 0/ 21.6/28.8 1/ SINGLE 10.8/ /16 10/17 7.2/9.6 1/ MULTIPLE CKT 1.6/ /6 6/60 RXBH-2A0J (-ton only) 7.2/9.6 1/ MULTIPLE CKT 2.6/0.0 0 /0 6/60 7.2/9.6 1/ MULTIPLE CKT.6/0.0 0 /0 6/60 RXBH-172A10C 7.2/9.6 / SINGLE 20.0/ / / RXBH-172A1C 10.8/1. / SINGLE 0.0/.6.6 /9 /0 RXBH-2A20C* 1./19.2 / SINGLE /6 60/70 7.2/9.6 / MULTIPLE CKT / / / RXBH-2A20C 7.2/9.6 / MULTIPLE CKT / /29 2/0 RXBH-2A2C* 18.0/2.0 / SINGLE 0.0/ /78 70/80 RXBH-2A2C RXBH-2A0C* (-ton only) RXBH-2A0C (-ton only)? Kit Connection Type A = Breaker B = Terminal Block C = Pullout Disconnect ➀ D Voltage = 80 Volts. *Values only. No single point kit available. NOTES: Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. If non-standard fuse size is specified, use next size larger standard fuse size. Largest motor load is included in single circuit or circuit 1 of multiple circuits. loads are balanced on phase models with or 6 heaters only. No electrical heating elements are permitted to be used with A voltage (11V) air handler. 9.0/12.0 / MULTIPLE CKT 1 2.0/ /2 0/ 9.0/12.0 / MULTIPLE CKT 2 2.0/ /7 /0 21.6/28.8 / SINGLE 60.0/ /9 90/ /1. / MULTIPLE CKT 1 0.0/.7.6 /0 /0 10.8/1. / MULTIPLE CKT 2 0.0/.7 0 8/ 0/ J voltage (208/20V) single phase air handler is designed to be used with single or three phase 208/20V volt electric heaters. In the case of connecting phase power to air handler terminal block without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead. Do not use 80V electrical heaters on 208/20V air handlers. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A21 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. 2

25 Electrical Wiring Electrical Wiring Power Wiring Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. Supply wiring must be 7 C minimum copper conductors only. See electrical data for product Ampacity rating and Protector requirement. Accessories Combustible Floor Base RXHB- Cabinet Size Jumper Bar Kit Ckt. to 1 Ckt. RXBJ-A1 is used to convert single phase multiple three circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Jumper Bar Kit 2 Ckt. to 1 Ckt. RXBJ-A21 is used to convert single phase multiple two circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Note: No jumper bar kit is available to convert three phase multiple two circuit units to a single supply circuit. Auxiliary Horizontal Overflow Pan Accessory RXBM- Nominal Cooling Capacity-Tons External Filter Rack RXHF-B17, B21, B2 Cabinet Size Filter Size In. [mm] Part Number* x 20 [06 x 08] RXHF-B x 20 [08 x 08] RXHF-B x 20 [6 x 08] RXHF-B2 *Accommodates 1" filter Combustible Floor Base Number RXHB-17 RXHB-21 RXHB-2 Auxiliary Horizontal Overflow Pan Accessory Number 1 1 /2 - RXBM-AC8 1 /2 - RXBM-AC61 A B Grounding This product must be sufficiently grounded in accordance with National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. A grounding lug is provided. Auxiliary Electric Kits RXBH- Kits include circuit breakers which meet UL and cul requirements for service disconnect. See the Electric Heat Electrical Data in this specification sheet for specific Kit numbers. External Filter Base RXHF- Cabinet Size Filter Size In. [mm] Part Number* A x 20 [08 x 08] RXHF x 20 [6 x 08] RXHF *Accommodates 1" or 2" filter Horizontal Adapter Kit RXHH- This horizontal adapter kit is used to convert Upflow/Downflow only models to horizontal flow. See the following table to order proper horizontal adapter kit. Coil Horizontal Adapter Kit Number (Single Qty.) Horizontal Adapter Kit Number (10-Pack Qty.) RXHH-A01 RXHH-A02 RXHH-A01 x 10 RXHH-A02 x /621 RXHH-A0 RXHH-A0 x /821/82 RXHH-A0 RXHH-A0 x RXHH-A0 RXHH-A0 x 10 External Filter Base RXHF- Cabinet Size Filter Size In. [mm] Part Number* A x 20 [06 x 08] RXHF x 20 [08 x 08] RXHF x 20 [6 x 08] RXHF *Accommodates 1" or 2" filter B B RXHF- 1 1 /2 [8 mm] RXHF-B B A 2

26 Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required)...Ten (10) Years *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 26

27 Notes 27

28 The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box Fort Smith, Arkansas Rheem Canada Ltd./Ltée 12 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P PRINTED IN U.S.A. 10/16 QG FORM NO. H11- REV.

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

CB29M Bulletin #490071 February 1996

CB29M Bulletin #490071 February 1996 ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating

More information

F9MXE. Product Specifications

F9MXE. Product Specifications 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Greensource iseries HY Model Unitary Air Handler/Fan Coil Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

SPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

SPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES 550.46 -TG1Y (196) SPLIT-SYSTEM CONDENSING S 0 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION The HRA Series condensing unit is the outdoor part of a versatile system of air conditioning. It

More information

Product Data. FV4B Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4B Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally

More information

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44. FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy

More information

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013 Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents

INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Models: BAYEAAC051A BAYEAAC05LG1A BAYEAAC081A BAYEAAC08LG1A BAYEAAC101A BAYEAAC10LG1A BAYEABC151A BAYEABC201A

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or damage to property. Installation

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and

More information

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Heating&Air Conditioning RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Amana RHF heat pumps and matching blower coils offer economy, superior heating and cooling comfort, plus installation

More information

RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com

RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com INDEX ACCESSORIES... 3-6 barb nylon fittings... 3-6 condensor pads... 3-6 condensor wall bracket... 3-7 electrical... 3-7 PIPE INSULATION... 3-7 REFRIGERATION SERVICE TUBING COPPER... 3-7 COILS INDOOR

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-12 Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-12 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

Product Data. FX4D Comfort Series Fan Coil Sizes 019 thru 061 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FX4D Comfort Series Fan Coil Sizes 019 thru 061 AIR HANDLER TECHNOLOGY AT ITS FINEST Comfort eries Fan Coil izes 019 thru 061 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The fan coils combine the proven technology of Carrier fan coil units with Puron, the environmentally sound refrigerant.

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1790-02-2607 (EN) Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin

More information

Installer s Guide 18-AH39D1-13

Installer s Guide 18-AH39D1-13 18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,

More information

GCS16-024-030-036-048-060

GCS16-024-030-036-048-060 Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

How To Install An Evaporator Coil

How To Install An Evaporator Coil EVAPORATOR COIL INSTALLATION INSTRUCTIONS EVAPORATOR COIL SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... System Requirements... Location Requirements... Drain Requirements... INSTALLATION INSTRUCTIONS...

More information

Liebert DS Thermal Management Unit

Liebert DS Thermal Management Unit Liebert DS Thermal Management Unit System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL Economizer Coil, Dual-Cool DX with Secondary

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Three Phase 4TWA3030A3000C 4TWA3030A4000C 4TWA3036A3000C 4TWA3036A4000C 4TWA3042B3000A 2½ 5 Tons 4TWA3042B4000A 4TWA3048A3000C 4TWA3048A4000C 4TWA3060B3000A 4TWA3060B4000A

More information

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB

More information

TECHNICAL MANUAL GDS8 & GHS8

TECHNICAL MANUAL GDS8 & GHS8 TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as

More information

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling. SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

Evaporator Coil Installation Instructions

Evaporator Coil Installation Instructions Part # 96654008 July 2010 Evaporator Coil Installation Instructions A-Coil Page 4 Multi-position A-Coil Page 4-7 Slab Coil Page 5 Horizontal A-Coil Top Connection Page 5 Horizontal A-Coil Side Connection

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

C26 Bulletin #210061 November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts)

C26 Bulletin #210061 November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts) NGINRING T loset Installation With Pulse21 Furnace and lectronic ir leaner Typical pplications UNS N FULL S UP- VPORTOR OILS IR-ONITIONING N HT PUMP 2 To 5 Ton (7.0 To 17.6 kw) Nominal Size OILS LOWR OILS

More information

CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS

CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS Description / Application Compact, versatile, right or left horizontal position May be used in closet, utility room, or basement Standard Finish Fully

More information

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO. Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODEL: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual : 2100-234 E Supersedes: 2100-234

More information

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS FOR COOLERS ABOVE +34ºF Low silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 BTU/HR./10ºF TD LSA LSE, LSR & LST FOR COOLERS AND FREEZERS FROM -20ºF TO +34ºF Low silhouette, draw

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products ECM Motors Manufactured By Regal Beloit Products and Applications- What s an ECM? ECM 2.3 series ECM 142 Arktic ECM 58mm Arktic ECM 59 Arktic SSC2 Arktic 51 GEXPRO Regal Beloit s distribution arm for all

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

Installation Instructions

Installation Instructions 05,06 Single Package, Displacement Ventilation or Single Zone Variable Airflow Rooftop Units Electric Cooling with PURONr (R---410A) Refrigerant and COMFORTLinkt Controls Installation Instructions IMPORTANT:

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

AIR-COOLED CONDENSERS Technical Guide

AIR-COOLED CONDENSERS Technical Guide BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Product Data. Split System Cooling 22-1904-1F-EN. March 2015

Product Data. Split System Cooling 22-1904-1F-EN. March 2015 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS. Models: WA182, WA242. Bard Manufacturing Company, Inc.

WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS. Models: WA182, WA242. Bard Manufacturing Company, Inc. INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: WA82, WA242 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 94...Moving ahead just as planned Manual No.: 200-369E Supersedes:

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information