Oildyne 108 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 2.8 lpm (3/4 gpm)
|
|
- Holly Carroll
- 7 years ago
- Views:
Transcription
1 Oildyne 18 Series Pressures to 21 bar (35 psi) s to 2.8 lpm (3/ gpm) aerospace climate control electromechanical filtration hydraulics pneumatics process control sealing & shielding
2 Features 18 Series Typical applications Positioning Hydraulic door operators Conveyor belt tensioners Medical chairs, beds, and equipment Recreational Vehicles Leveling Slideouts Tent Trailers Clamping Tool fixtures and jigs Hydraulic brakes Crimping tools Arbor presses Truck restraints Cycling Garbage compactors Valve operators Press controls Packing equipment Indexing tables Lifting Handicap lifts Scissor lift tables Pallet movers 18 Series Self-contained Our compact 18 Series power units let you put the power where you need it. They re completely self-contained with an AC or DC motor, gear pump, reservoir, internal valving, load hold checks and relief valves. The 18 Series models are designed for intermittent service and come in four standard pump sizes which produce flows of,.187,.26, and.321 cubic inches per revolution. Locking check valves are available in all models. Performance will vary with the type of fluid used. Several hydraulic circuits are available. 18 Series units are available with single- or bidirectional rotation. Single units are commonly used to charge accumulators, power one-direction hydraulic motors and cylinders, provide pilot flow to servo valves, pressurize lube systems and supply multifunction circuits with external valving. Bi-directional, reversible units operate double-acting cylinders and two-way motors. We d like to work with you on your special hydraulic applications. Our people know small hydraulics. We know how to design them, how to make them and how to apply them. Therefore, we can offer you a practical, economical solution to your fluid power problems. Oildyne has pioneered top quality, compact hydraulic components since We can provide standard products or custom design high pressure, space saving solutions to your specific needs.
3 Technical Information Standard Product Ordering Code Series STANDARD ORDERING CODE 18 POWER UNIT - includes relief valve(s) AE AM BE BI HA HD IA MOTOR CODE 12 vdc Permanent Magnet 12 vdc Series Wound 2 vdc Permanent Magnet 2 vdc Series Wound 115 vac, 1 phase, Open 23 vac, 1 phase, Open 36 vdc Permanent Magnet PUMP TYPE S Standard C Cold Temp RV SETTING (Right Hand Port) Use for Single Dir. In multiples of 1 psi Examples = psi 12 = 12 psi 29 = 29 psi RV SETTING (Left Hand Port) In multiples of 1 psi Examples = psi 12 = 12 psi 29 = 29 psi A B C D F G H I J P Q R S PUMP SIZE 1 CIPR CIPR CIPR CIPR 26 cu. in. (13 cu. in. usable) 6 cu. in. (23 cu. in. usable) 6 cu. in. (26 cu. in. usable) Alternate orientation version of C 122 cu. in. (82 cu. in. usable) 69 cu. in. (6 cu. in. usable) 1/2 gallon usable 1 gallon usable 1-1/2 gallon usable 1/ gal. usable (plastic) 1/2 gal. usable (plastic) 1 gal. usable (plastic) 3/ gal. usable (plastic) NOTES: C and D reservoirs are available as Vertical Mount ONLY. A reservoir with pump 32 is available ONLY as vertical mount. V H PORTS 1 7/16-2 (SAE -) 2 7/16-2 (Inv. Flare) 3 1/8" Pipe (NPSF) 1/8" Pipe (BSPP) MOUNTING Vertical (motor up) Horizontal CIRCUIT TYPE NN Single direction WW Single direction with check RR Reversible LL Reversible locking RB Reversible with Back Pressure LB Reversible locking with Back Pressure Each Solenoid Valve option below includes the WW circuit: S1 12 vdc, Normally Closed S2 2 vdc, Normally Closed S3 12 vac, Normally Closed S 2 vac, Normally Closed S5 12 vdc, Normally Open S6 2 vdc, Normally Open S7 12 vac, Normally Open S8 2 vac, Normally Open ORDERING CODE INSTRUCTIONS Select the model code needed based on catalog information. All boxes above must be filled in before Oildyne can process the order. If the power unit is a single direction unit use '' for the (Right Hand) relief valve box. Hydraulic Fluid ATF, OD18, or other clean hydraulic oil with a viscosity of 15 to 3 SUS at 38 C (1 F) is acceptable. If another type of fluid is needed, please consult the factory. Temperature Range Normal operating range is +2 F to +1 F. Please review your application with the factory for uses below -7 C and over +6 C (+2 F and over +1 F). ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE FOR POWER UNIT CONFIGURATIONS OTHER THAN THOSE SHOWN PLEASE CONSULT OILDYNE. 5
4 Technical Information 18 Series 12/2 V DC Permanent Magnet Motor Code AE BE Motor Type: AE and BE For intermittent duty cycles. 12/2 V DC Series Wound Motor Code AM BI Motor Type: AM and BI For intermittent duty cycles. +12 VDC SPLY (AM) +2 VDC SPLY (BI) SOL 1 SWITCH CONTACTS BLUE NOTES: AM MOTOR HAS 1 AMP THERMAL BREAKER; BI MOTOR HAS 5 AMP THERMAL BREAKER. LEFT HAND PORT SOL SWITCH SPDT CENTER OFF TOGGLE SWITCH MOTOR 1 2 RIGHT HAND PORT SOL 2 SWITCH CONTACTS GREEN BLACK -12 VDC SPLY (AM) -2 VDC SPLY (BI) 115/23 V AC Capacitor Start Motor Code HA HD Motor Type: HA and HD Dual voltage 1/3 HP, 6/5 hz, 35/285 rpm, intermittent duty, single phase, open frame. Capacitor and relay included. LEFT HAND PORT GREEN OR ORANGE 115 VOLTAGE CONNECTION 23 VOLTAGE CONNECTION Wiring Diagram: AE BE DPDT CENTER OFF TOGGLE SWITCH MOTOR RIGHT HAND PORT BLUE OR BLACK DPDT CENTER OFF TOGGLE SWITCH USABLE TO 2 AMPS SOL SWITCH B R O BLUE W WHITE N BLACK MOTOR GREEN/YELLOW RED YELLOW ORANGE 7 AMP TO REVERSE, INTERCHANGE RED AND BLACK LEADS B R O WHITE W BLACK N GREEN/YELLOW BLUE MOTOR ORANGE RED YELLOW 3 AMP -12 VDC SPLY (AE) -2 VDC SPLY (BE) +12 VDC SPLY (AE) +2 VDC SPLY (BE) Wiring Diagram: AM BI Wiring Diagram: HA Wiring Diagram: HD 2 3 RELAY 2 3 RELAY L MFD/125V L-1 L MFD/23V L-1 Output - lpm (cipm) Output - lpm (cipm) Output - lpm (cipm).82 (5) ().9 (3) (2).1 Pump ( cipr) with AE / BE Motor.16 (1) (5) (1) (15) (2) (25) (3).1 Pump ( cipr) with AM / BI Motor (1) (8) (6) () (2).82 (5) ().9 (3) (2).16 (1) (5) (1) (15) (2) (25) (3) (35).1 Pump ( cipr) with HA / HD VAC (5) (1) (15) (2) (25) (3) Amps - Amps - Amps Note: 5 hz performance is 83% of curves shown. 6
5 Technical Information 18 Series Output - lpm (cipm) 1.2 (75) (6).7 (5).9 (3).25 (15).19 Pump (.187 cipr) with AE / BE Motor (5) (1) (15) (2) (25) (3) Amps Performance data based on 21 C ( 7 F) Output - lpm (cipm).25 Pump (.26 cipr) with AE / BE Motor (1) (8) (6) () (2) (5) (1) (15) (2) (25) (3) 5 - Amps Output - lpm (cipm) 2.5 (15) 2. (12) 1.5 (9) (6).9 (3).327 Pump (.321 cipr) with AE / BE Motor 3 (5) 69 (1) 13 (15) (2) - Amps Output - lpm (cipm).19 Pump (.187 cipr) with AM / BI Motor 2.5 (15) 2. (12) 1.5 (9) (6).9 (3) (5) (1) (15) (2) (25) (3) (35) - Amps Output - lpm (cipm).25 Pump (.26 cipr) with AM / BI Motor 3.3 (2) 2.6 (16) 2. (12) (8) () (5) (1)(15) (2) (25) (3) - Amps Output - lpm (cipm).327 Pump (.321 cipr) with AM / BI Motor.1 (25) 3.3 (2) 2.5 (15) (1).82 (5) 3 (5) 69 (1) 13 (15) 138 (2) (25) - Amps Output - lpm (cipm).19 Pump (.187 cipr) with HA / HD Motor (1) (8) (6) () VAC (5) (1) (15) (2) (25) (3) Amps Output - lpm (cipm).25 Pump (.26 cipr) with HA / HD Motor (1) (8) (6) 115 VAC (2) 23 VAC (5) (1) (15) (2) (25) (3) Amps Note: Performance data is for reference only. Output - lpm (cipm).327 Pump (.321 cipr) with HA / HD Motor 2. (125) (1) (75).82 (5) VAC (3) (6) (9) (12) (15) (18) Amps 7
6 Circuits 18 Series RV RV WW CIRCUIT NN CIRCUIT RV ThermalReliefValves Why? The thermal relief valve s () purpose is to allow a bleed off of built up pressure due to thermal expansion of the fluid or to act as a (limited) shock load protection, should a cylinder in the system get bumped. The thermal relief valve is included in circuits using a pilot operated check valve. The single direction units get one; the reversing units get two. It is located between the check valve and the 18 Series pump outlet port. It is a fixed relief valve with a pressure setting approximately 1-1 bar (15-2 psi) above the system relief valve pressure. S* CIRCUIT 8
7 Circuits 18 Series BACK PRESSURE CIRCUIT HPRV LPRV HPRV LPRV RR CIRCUIT RB CIRCUIT BACK PRESSURE CIRCUIT HPRV LPRV HPRV LPRV LL CIRCUIT Back Pressure Circuits Why? The basic reversible circuit is essentially a closed loop. The oil returning from the system is fed back into the pump inlet. When a cylinder is being retracted more oil is being returned to the power unit than is leaving it due to the rod volume. This results in the side relief valve cracking open allowing the rod volume of oil to go back to the tank. The larger the rod volume the more open the relief valve will be. In many applications this is not a problem. However, if work is being done on the retract stroke, or if a pressure switch is used to signal the cylinder is fully retracted, the back pressure circuit is required. This circuit allows the rod volume of LB CIRCUIT oil to return to the reservoir through a special shuttle spool, before it reaches the pump. Full relief valve pressure is then available to retract the cylinder, also preventing a pressure switch from tripping before the full retract position is achieved. Recommended uses: In systems where work is being done on the retract stroke Where a pressure switch is used to signal the full retract position In systems requiring a faster retract than extend speed 9
8 2 Catalog HY /US Dimensions Overall Dimensions FRONT VIEW STANDARD ORIENTATION IS SHOWN ALTERNATE ORIENTATION WOULD HAVE FILLER CAP ON LEFT SIDE (IN FRONT VIEW) 18 Series SIDE VIEW A B BACK VIEW (.) PORT SIZE SEE CODING FILLER CAP 3.7 (1.21) C THIRD ANGLE PROJECTION With Solenoid Valve UNUSED PRESSURE PORT PLUG 29.2 (1.15) 7/16-2 PRESSURE PORT FILLER CAP MAX MIN (5.88) (1.15) SOLENOID VALVE 12 VDC MOTOR MAX MIN 85.3 (3.36) 6 CU IN 75.±.8 (Ø2.97±.3) (.97) 3.7 (1.21) 83.8±1.5 (3.3±.6) 97.3 (3.83) 29. (1.16) 29. (1.16) 6.9 (2.55) 2 MOUNTING HOLES 3/8-16 UNC-2B X 7/16 DEEP Motor Dimensions ±. (±.5) A B C AE/BE (2.97) (.97) (9.5) AM/BI (3.77) (5.96) (1.9) IA (2.97) (5.7) (9.61) HA/HD (3.9) (6.3) (1.88) (1.15) (1.15) 11.7±1.5 (5.58±.6) Reservoir Dimensions (6.38) 1.27±.8 (.5±.3) Note: All dimensions in mm (inches). Note: refer to page 17 for information on the P, Q, R and S reservoirs. 19. (5.88) 8 HDPE (.88) 91.2 (Ø3.59) 93.9 (Ø3.7) 8.3 (3.16) 93.9 (Ø3.7) A 28 CU. IN. (13 CU. IN. USABLE) ALUMINUM (59 CC: 213 CC USABLE) 161. (6.3) 85.3 (3.36) B 6 CU. IN. (23 CU. IN. USABLE) ALUMINUM (75 CC: 377 CC USABLE) 1 (Ø.) "G" #3-69 CU. IN. (6 CU. IN. USABLE) EXTRUDED ALUMINUM (113 CC: 75 USABLE) C 6 CU. IN. (26 CU. IN. USABLE) HIGH DENSITY POLYETHYLENE WITH UV ADDITIVE STD. (75 CC: 26 CC USABLE) (1.5) (6-7/8) H 1/2 GAL (2 Liter) I 1. GAL ( Liter) J 1.5 GAL (5.6 Liter) 12.3 (5.6) 1 (Ø.) "F" 122 CU. IN. (82 CU. IN. USABLE) STEEL (2 CC: 13 CC USABLE) "H, H, I, I, J" J - STEEL STEEL 18.6 (7.27) (12.27) 13.3 (16.27) 1
Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
More information2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationMONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationExample. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
More informationSeries TMM Axial Piston Motor. Technical Information
Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer
More informationVariable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
More informationQuiz On Information Learned From Chapter 1
Quiz On Information Learned From Chapter 1 1. Most hydraulic circuits are designed by: A. mechanical engineers. B. fluid power engineers. C. fluid power distributor salesmen. 2. Atmospheric pressure at
More informationIn addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).
DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP
More informationHydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More informationMANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
More informationAccumulators and Receivers
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog
More informationROTARY GEAR FLOW DIVIDERS
ROTARY GEAR FLOW DIVIDERS Concentric AB Innovation + Technology = Sustainability GC and D Series Rotary Gear Flow Dividers Intensifier - Combiner (European and U.S. Versions) Field-proven Concentric Hydraulic
More informationSeries PVP Variable Volume Piston Pumps
Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationElectro-Mechanical Landing Gear System. Landing Gear and Brakes
Electro-Mechanical Landing Gear System N O 2 D U A L F E D B U S LANDING RELAY 5A DOWN EMERGENCY EXTENSION DOWN LIMIT GROUND AIRBORNE DOWN LIMIT Landing Gear and Brakes DOWNLOCK HOOK ENGAGED GROUND AIRBORNE
More informationCheck Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationThe Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com
The Secret of Hydraulic Schematics BTPHydraulics www.iranfluidpower.com www.iranfluidpower.com Table of Contents The Secret to Reading and Interpreting Hydraulic Schematics... 1 Hydraulic System Schematics...
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationLOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
More informationWHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
More informationPressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
More informationFlow divider (flow distributor), type TQ
Flow divider (flow distributor), type TQ Pressure p max = 0 bar Flow Q CN max = 00 lpm Share ratio = :. General Task Flow dividers type TQ are self-regulating valves, which largely irrespective of the
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More informationTorqPlus TM Electric Valve Actuators and Controls
TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationAQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction
Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationSchematic Symbols Chart (Design Hydraulic and Pneumatic circits)
Page 1 of 6 (Home) Symbols / Visit us on: Fluid Power, Automation and Motion Control for all Industries About Us Products Services Catalogs Place an Order Training & Information Contact Us Employee Access
More informationMono-Block II Installation & Operation Manual
Mono-Block II Installation & Operation Manual Enraf Fluid Technology UK, Ltd. Enraf Fluid Technology USA, Inc. 6 Pennant Park, Standard Way 2000 Northfield Court Fareham, Hampshire, England PO16 8XU Roswell,
More informationIndex 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
More informationDelta Power Company 4484 Boeing Drive - Rockford, IL 61109
INDEX Description Page Delta Power Rotary Flow Divider, Positive Displacement (Application Data) 36 P Series, Equal Flow Two Sections 39 P Series, Equal Flow Multi-Sections 40 PM Series, Equal Flow Multi-Sections
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
More informationZU4-Series, Portable Electric Pumps
ZUSeries, Portable Pumps Shown from left to right: ZU30ME, ZUSEH, ZU30PEK Tough. Dependable. Innovative. ZUSeries Features and Options For special requirements see factory installed features and options.
More informationHydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
More informationRexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
More informationACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
More informationElectro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationLT Series Lubricant Management System (LT-LMS)
FLUID HNDLING: LT Series Lubricant Management System (LT-LMS) This system combines filtration, storage, and breathers in one simple solution to keep your lubricants clean and dry. The Overview The LT-LMS:
More informationHYDRAULICS AND HWH SYSTEMS
HYDRAULICS AND HWH SYSTEMS 1. PREFACE This is a discussion of basic hydraulics which can help with the diagnostics and repair of HWH hydraulic leveling and room extension systems. The first section of
More informationCSD WATER REMOVAL FILTERS FOR DIESEL
CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working
More informationCatalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...
More informationHydraulic Troubleshooting PRESENTED BY
Hydraulic Troubleshooting PRESENTED BY NORMAN KRONOWITZ Introduction Welcome to the CMA/Flodyne/Hydradyne s Hydraulic Troubleshooting presentation. We will introduce many aspects of troubleshooting hydraulic
More informationCOUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
More informationIndustrial Hydraulic Remote Controlled Monitor
Industrial Hydraulic Remote Controlled Monitor Models: 294-11XBHC-N4X, 294-11XBHC-N7/4, 299-20XHC-N4X, & 299-20XHC-N7/4 Installation, Operating, & Maintenance Instructions 1302 WEST BEARDSLEY AVENUE P.O.
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationZU-Series, Electric Pumps
ZU-Series, Electric Pumps Shown from left to right: ZU4304MB, ZU4420SB-H, ZU4304PB-K eatures Z-Class high-efficiency pump design; higher oil flow and bypass pressure, cooler running and requires 18% less
More informationUniquely designed and engineered specifically for the pulp and paper industry.
Universal SPU2 Series Uniquely designed and engineered specifically for the pulp and paper industry. For more than half a century, Waukesha Cherry-Burrell has been a leader in the design, manufacturing
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationTool Turrets and Tool Discs
Our other products Automatic Tool Changer Chucking Cylinders Tool Discs Indexing Tables Tool Turrets and Tool Discs Pragati Automation Pvt. Ltd. 1, IV Phase, 11th Cross, Peenya Industrial Area Bangalore
More informationSIMPLIFIED VALVE CIRCUIT GUIDE
NA-09 FLOW CONTROL METERED- FREE FLOW UT OUT CYLDER TENDED SOLENOID NO. A Guide to Understanding Pneumatic Directional Control Valves SIMPLIFIED CIRCUIT GUIDE 0 0 0 0 Compressed Air Valves Directional
More informationOCTOPUS SELECTION & INSTALLATION GUIDE
OCTOPUS SELECTION & INSTALLATION GUIDE 38mm BORE LINEAR ACTUATOR STYLES LAM & LAR A. GENERAL DESCRIPTION: The Octopus hydraulic linear actuator is a simple, efficient and reliable way of driving the rudder
More informationPiston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
More informationDesigned for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
More informationTable of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
More information15/40/80CN Series Medium Pressure Filters
1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)
More informationHydraulic Landing Gear System
Hydraulic Landing Gear System CENTER BUS MAIN POWER RELAY 60A 5A SERVICE VALVE 5 LANDING GEAR TIME DELAY PCB TIME DELAY 14 AUX. RETURN AUX. PRESS. UP SELECTOR VALVE POWER PACK ASSEMBLY REGULATED BLEED
More informationPressure Relief and Regulating Valves
Pressure Relief and Regulating Valves With blocked center directional valves and variable displacement pumps, or open center directional valves and fixed displacement pumps where fast response, low leakage
More informationPVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems
185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationPipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
More information1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: regulateurs@regulateurs-europa.com 1115 4G
More informationFlow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationControl block EDD Modular Directional Valve
Control block EDD Modular Directional Valve 2 Control block EDD Modular Directional Valve Bosch Rexroth Oil Control S.p.A. introduces this innovatory Directional Control Valve size 8 which allows to create
More informationTroubleshooting Guide for Jacks Down LED Lights
Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any
More informationPART 2 FORKLIFT HYDRAULIC SYSTEM
PART 2 FORKLIFT HYDRAULIC SYSTEM Chapter 1 Description and Operation Component Locations & Circuit Layouts 1 Hydraulic Pump 11 Control Valve 14 Valve Section Oil Flows 15 Anti-Cavitation Valve 22 Velocity
More information15CI and 25CI Reversing Motor Pumpset Owner's Manual
ComNav Marine Autopilots #15-13511 Crestwood Place Richmond, BC Canada V6V 2G1 Telephone: 604-207-1600 Fax: 604-207-8008 In Canda or the U.S.A: Toll Free Phone: 1-800-428-0212 Toll Free Fax 1-800-470-9611
More information301.7D. Mini Hydraulic Excavator
301.7D Mini Hydraulic Excavator Engine Weights Gross Power (ISO 14396) 17.9 kw 24.3 hp Operating Weight with Canopy 1610 kg 3,550 lb Net Power 13.2 kw 17.7 hp Operating Weight with Cab 1720 kg 3,792 lb
More informationIndustrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.
Industrial Valves Marketing Catalog Reliable and continuous performance in the world's most demanding and rigorous applications. Demanding Applications Call for Eaton Valves to control machine functions,
More informationNAGEL ECO 180 FLEXIBLE HONING SYSTEM
NAGEL ECO 180 FLEXIBLE HONING SYSTEM NEW DEVELOPMENT For Small and Medium Production Runs In-process gauging, Roughing and finishing in a single spindle Tel: 734-426-1812 www.nagelusa.com MACHINE HIGHLIGHTS
More informationPVH131/141 Variable Displacement Piston Pump - 11 Design
Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque
More informationSMR Series Submicronic Removal Fluid Purifi cation Systems
SMR Series Submicronic Removal Fluid Purifi cation Systems 193 SMR Series Applications The SMR Series is the smart purification solution for fluid flow in the 2-10 GPM (8-38 LPM) range. The SMR contains
More informationBasic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain
Airline Hydraulic's Main Page Basic Symbols Lines continuous line flow line dashed line pilot, drain envelope long and short dashes around two or more component symbols. Circular Square Diamond large circle
More informationDirectional seated valves type VP 1
Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual
More informationTechnical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
More informationLINEAR MOTION CONTROL
LINEAR MOTION CONTROL Technical Data Sheet Static Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these
More informationWelding Reels HANNAY REELS. For use for: Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5. The reel leader.
Welding Reels HANNAY REELS For use for: The reel leader. Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5 Series SWCR/WCR Arc Welding Reels: Power or Manual Rewind To handle cable to 400 amps.
More informationPRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited
PRODUCT RELEASE CKMTA12 / 24 Copyright 2011 by ARB Corporation Limited ARB 4x4 ACCESSORIES 720 SW 34Th Street Tel: (425) 264-1391 Renton, Washington 98057 Fax: (425) 264-1392 USA North and South American
More informationSteering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min
Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device
More information220 Series Piston Pump Typical Applications Features and Benefits
Introduction 220 Series Piston Pump Eaton s new 220 Series piston pump signifies a step change in the generation of hydraulic power. Utilizing the latest developments in hydraulic pump technology, the
More informationPVS Series - Models 185, 600, 1200, 1800 and 2700
PVS Series - Models 185, 600, 1200, 1800 and 2700 Reduce the catastrophic results of water contamination Eliminate water from the hydraulic system The PVS Series Portable Purification Systems, available
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
More informationRadial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
More informationMaterial taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001
Pressure Control Chapter 3 Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Introduction Pressure control is a key element in the design of any circuit. Used correctly, it can
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power