GPC AutoPrep 2000 Model SP 2000

Size: px
Start display at page:

Download "GPC AutoPrep 2000 Model SP 2000"

Transcription

1 Gel Per me ation Chro ma tog ra phy (GPC) Clean up Sys tems GPC AutoPrep 2000 Model SP 2000 Universal cleanup method for or gan ic com pounds Extend the life of analytical col umns Reduce sample loss Increase recoveries Multiple column options A World of Solutions

2 Simplify the Process Gel permeation chromatography (GPC) cleanup has proven to be the most versatile and convenient sample cleanup technique for a wide range of sample matrices. GPC cleanup eliminates sulfur and high-molecular-weight compounds, such as lipids, polymers, and proteins, from organic sample extracts prior to GC, HPLC, LC/MS, or GC/MS analysis. If not removed, these interfering compounds clog columns and injectors, foul GC detectors, and cause sig nifi cant losses in chromatographic efficiency. GPC cleanup greatly re duc es GC down time, prevents costly delays, and extends the life of expensive analytical col umns. Regulatory Methods Using GPC USEPA SW-846 Method 3640A USEPA Contract Laboratory Program, Statement of Work for Organics Analysis, Document OLM01.0 FDA Pesticide Analytical Manual, Vol. 1 USGS SOP No. HC521 A USDA and USDI GPC Protocols, Analytical Chemistry Laboratory Guidebook (Residue Chemistry) AOAC Cleanup Methods for Meat Products With your needs in mind, OI Analytical simplified the GPC process by developing advanced cleanup systems built for reliability and enhanced ease-of-use. The GPC AutoPrep 2000 and the Model SP 2000 systems provide unmatched performance with a versatile and wide selection of column options that meet the de mands of the busy analytical laboratory. GPC AutoPrep 2000 The Ideal Automated Sys tem for GPC Cleanup The GPC AutoPrep 2000 seamlessly automates the GPC cleanup process for high throughput with complete reliability in a single system. The enhanced design integrates an autosampler, al low ing up to 60 samples to be au to mat i cal ly cleaned and collected. With Win dows -based WinSEP software, the GPC AutoPrep 2000 provides flex i bil i ty and total control over the GPC cleanup process. Automatic cleanup of up to 60 crude residue extracts Modular, low main te nance design Interchangeable sample loops No carryover con tam i na tion the flow path au to mat i cal ly rinses between samples Reduced sample loss Fewer sample handling errors Higher analyte re cov er ies Automated, Precise Sample Handling Designed for reproducibility and ease-of-use, the GPC AutoPrep 2000 fea tures superior sample handling ca pa bil i ties for high volume and timely results. Samples are transferred into vials and placed in the sample tray on the autosampler mod ule. The system then au to mat i cal ly draws up samples through precise sample loops and injects them onto the GPC column for sep a ra tion. High-mo lec u lar-weight ma te ri als, such as lipids, elute from the column first and are dis card ed. The remaining sample with the analytes of interest collect in the sample flask on the collection tray for further pro cess ing. Late-eluting fractions, such as sulfur in soil samples, can be directed to waste after col lect ing the compounds of interest. The system then rinses in prep a ra tion for the next sample.

3 Automatic cleanup of up to 60 samples Unlimited storage of methods and sequences Extensive reporting and data management capabilities Log file and password protection Comprehensive system monitoring Sample se quenc e modification during a run Programmable dual collect and dump times Automated pump shut down and column by pass Column cal i bra tion performance monitoring for any deterioration in res o lu tion WinSEP GPC Control Software Complete Au to ma tion Made Simple WinSEP GPC control software is an easy-to-use, powerful Windows-based application that manages and controls the GPC AutoPrep WinSEP monitors and presents information about the GPC pro cess, allows the op er a tor to control the instrument, and provides editing of se quenc es and methods. It gives access to detailed run results, which can be viewed within WinSEP, easily exported to LIMS or other data man age ment ap pli ca tions, or printed via WinSEP s integrated report generation library. WinSEP also features an integrated database and data archival capabilities. Original data is protected and cannot be modified, as required for GLP com pli ance. View, defi ne, or change a method from the Method page. From the Sequence page, create or modify a se quence, specifying which samples to process and how they are treated. View details of today s calibration and com pare them to previous cal i bra tions on the same column.

4 GPC Clean up Columns Perfect Partners for GPC Clean up Systems Complete your GPC cleanup system by choosing from a comprehensive array of columns. All of OI Analytical s GPC col umns provide superior per for mance and con sis tent, reliable results. Envirobeads S-X3 Column Exceptional Capacity, Reliable Per for mance The Envirobeads S-X3 high-capacity column is the standard of the in dus try. Com prised of a traditional glass column, the Envirobeads S-X3 column is filled with 70 g of resin and prepared using a variety of mobile phase sol vents, such as methylene chloride, 50/50 me th yl ene chlo ride/cyclohexane, or 70/30 ethyl acetate/cyclopentane. This reliable performer handles the tough cleanup jobs, accepting up to 10 ml of sample per run and re mov ing up to 1 g of material from a sample. The reusable glass column can be re pack ed with fresh resin and equil i brat ed with compatible solvents. The Envirobeads S-X3 column is ideally suited for a wide variety of ap pli ca tions and uses. GPC cleanup using the Envirobeads S-X3 column fully com pli es with USEPA Method 3640A and CLP s Statement of Work. High-capacity column Fully compliant with USEPA, CLP, FDA, USDA, USGS, and AOAC re quire ments Rugged, reusable glass column Prepared using a variety of sol vents (mobile phase) EnviroSep-ABC Column Speed, Resolution, and Throughput The EnviroSep -ABC high-efficiency column provides greater chro mato graph ic resolution for optimum results. Using a stainless steel column, special fittings, and smaller diameter 10-µm resin beads, the EnviroSep-ABC column operates at much higher pressures to achieve fast run times for high-efficiency GPC cleanup. The EnviroSep-ABC column is com pat i ble with a wide range of solvents and can be re-equilibrated with another solvent mixture when a different application or sample type needs to be run. With sample volumes of up to 5 ml and a column capacity of up to 0.5 g, the EnviroSep-ABC column offers high-resolution results without compromising value or sample throughput. Reproducible, highres o lu tion col umn Fully compliant with USEPA and CLP re quire ments High-pressure operation Fast run times, <30 minutes Com pat i ble with a wide variety of solvents Optima Column Rapid, Economical Cleanup The Optima small-scale column increases sample throughput, reduces solvent usage, and decreases the cost of sample preparation. Consisting of an inert Teflon column with a smaller inner diameter and shorter length than tra di tion al glass columns, the Optima column significantly shortens pro cess ing times. Complete a GPC cleanup run in as little as 28 minutes per sample using only 140 ml of solvent. Small scale does not mean small capacity. This column handles up to 0.5 g of material from 2.5 ml of sample. The Optima column is the low-cost alternative for applications that do not require USEPA or CLP compliance. Fast sample throughput Significantly reduced solvent usage Lower sam ple preparation costs Inert Teflon column

5 Model SP 2000 GPC Sample Cleanup System Compact, Efficient, and Affordable Applicable to all GPC clean up methods Manual syringe load ing of the sample into a cal i brat ed loop Interchangeable sam ple loops Integrates with the UV De tec tor/chart Re cord er for column calibration Control of run time, start, flow rate, and duration of collected fraction from the easy-to-use keypad The Model SP 2000 GPC Cleanup System is the simple and economical solution for GPC cleanup. This highly-affordable instrument uses the same columns and achieves the same precise results as an au to mat ed GPC system. The Model SP 2000 consists of an isocratic HPLC pump, sample injector, switching valve, and control module. After manual injection into a calibrated sample loop, switching the valve to the inject position introduces the sample onto the column. The fraction containing the desired analytes collects at a predetermined time into the collection vessel. Flow rate, total anal y sis time, and start and duration of fraction col lec tion are pro grammed using the easy to use keypad on the control module. UVD-1000 UV Detector/Chart Recorder Compliant with USEPA GPC col umn calibration re quire ments Reliable, repeatable re cord ing Complete ready-to-use package LED display for readout of calibrated ab sor bance Compact, economical design Semipreparative flowcell The UVD-1000 is specifically designed for use with the GPC AutoPrep 2000 and the Model SP 2000 to meet USEPA GPC column calibration re quire ments. This eco nom i cal package comes complete with a fixed wave length UV detector set for operation at 254 nm, a semipreparative flowcell, a 100-mm flatbed strip chart recorder, and fittings. Compact in size, the UVD-1000 s strip chart recorder is full of features. Its 12 calibrated full-scale ranges, from one to five volts, accommodate most input signals. The patented Pulse Mod u lat ed Servo system provides reliable and repeatable re cord ing and is protected from large signal variances by an elec tron ic servo power shut down. Corn oil Bis(2-ethylhexyl)phthalate Meth ox y chlor Perylene Sulfur 0 min 57 min USEPA Method 3640A GPC calibration standard separated using an Envirobeads S-X3 column.

6 Expand Your Options Sample Trays, Collection Trays, and Accessories OI Analytical offers a wide range of sample and collection options and other GPC accessories to fit any experimental design. Sample Trays for the GPC AutoPrep x 100-mm tubes (7 ml) x 100-mm tubes (15 ml) mL VOA vials 21 Kuderna-Danish collection tubes Other options available by special request Sample Loops for the GPC AutoPrep ml (for use with the Optima column) 5.0 ml 10.0 ml Sample Loops for the Model SP ml (for use with the Optima column) 5.0 ml Septum Piercing for the GPC AutoPrep 2000 Septum piercing needle Septa and sample tubes (16 x 100 mm) Septa and collection tubes (25 x 200 mm and 39 x 200 mm) Covers for RapidVap 500-mL tubes Column Switching for the GPC AutoPrep 2000 Two-column holder Column switching accessory and tubing Collection Trays for the GPC AutoPrep x 200-mm tubes (70 ml) x 200-mm tubes (170 ml) mL TurboVap tubes mL fl at-bottomed fl asks mL TurboVap II tubes mL fl at-bottomed fl asks mL RapidVap tubes Other options available by special request Glassware 25 x 200-mm tubes 39 x 200-mm tubes 16 x 100-mm tubes 125-mL fl at-bottomed fl ask 250-mL fl at-bottomed fl ask 2.5-L amber solvent bottle Envirobeads is a registered trademark of Bio-Rad Laboratories. EnviroSep is a trademark of Phenomenex, Inc. RapidVap is a registered trademark of Labconco Corp. Teflon is a registered trademark of E.I. DuPont de Nemours. TurboVap is a registered trademark of Zymark Corp. Windows is a registered trademark of Microsoft Corp. 151 Graham Road, PO Box 9010 College Station, Tex as FAX (979) (979) (800) USA/Canada oimail@oico.com A World of Solutions Publication

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Application Note 25570306 Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Keywords Gel Permeation Chromatography GPC AutoPrep 2000 Pesticides RapidVap N2 System

More information

[ Care and Use Manual ]

[ Care and Use Manual ] The Waters GPC Cleanup System uses two Envirogel GPC Cleanup Columns to perform routine cleanup of environmental samples as specified by EPA Method 3640A, GPC Cleanup. The columns, 19 x 150 mm and 19 x

More information

ASCENT TM Integrated Shipment Management

ASCENT TM Integrated Shipment Management ASCENT TM Integrated Shipment Management Software Solutions Production mail Shipping systems Copier systems Facsimile systems Mailing systems Management services Financial services Consulting Supplies

More information

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA An Automated Method for the Fractionation of Extractable Petroleum Hydrocarbons (EPH) from Water and Soil Extracts Using the Gilson GX-274 ASPEC System Keywords: Aliphatic Hydrocarbons, Aromatic Hydrocarbons,

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry. IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The

More information

Smartline HPLC by design

Smartline HPLC by design HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as

More information

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides

More information

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Automation of Solid Phase Extraction and Column Chromatographic Cleanup Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for

More information

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)

More information

Phoenix 8000. Apollo 9000. Laboratory TOC Analyzers and Services Designed To Meet Your Needs

Phoenix 8000. Apollo 9000. Laboratory TOC Analyzers and Services Designed To Meet Your Needs Laboratory TOC Analyzers and Services Designed To Meet Your Needs Simple, Reliable and Dependable Instruments Low Cost of Operation Expert Service and Support Phoenix 8000 UV-Persulfate Oxidation Technology

More information

SCION SQ Series GC-MS

SCION SQ Series GC-MS SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative

More information

The Sievers 900 Series TOC Analyzers

The Sievers 900 Series TOC Analyzers GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series

More information

This study was performed in collaboration with CT Laboratories of Baraboo, WI, USA.

This study was performed in collaboration with CT Laboratories of Baraboo, WI, USA. Automated Gel Permeation Chromatography (GPC) Clean-up of Soil Extracts Prior to Analysis for Semivolatile Organic Compounds by GC/MS (USEPA Method 8270) Keywords: Automated GX-271 GPC Clean-up System,

More information

The Gold Standard in Volatiles Analysis

The Gold Standard in Volatiles Analysis The Gold Standard in Volatiles Analysis Innovation in Purge-and-Trap Technology Purge-and-Trap (P&T) sample introduction for GC and GC/MS has been in use for over 30 years; however, the innovation and

More information

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers Automation, sample preparation Autosamplers for Ion Chromatography Dionex AS-AP Autosampler Advanced Features Perform full-loop, partial-loop,

More information

designed to never let you down PerkinElmer Series 200 HPLC Systems

designed to never let you down PerkinElmer Series 200 HPLC Systems designed to never let you down PerkinElmer Series 200 HPLC Systems an inside look at the Series 200 HPLC systems PerkinElmer knows you need to rely on your high performance liquid chromatography (HPLC)

More information

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes Brussels, 18th May 2005 CED No 494 rev 2 Final TAXUD/3711/2004 POETRY:

More information

AUTOMATED SAMPLE PREPARATION INTELLIGENT SYSTEM SOLUTION

AUTOMATED SAMPLE PREPARATION INTELLIGENT SYSTEM SOLUTION AUTOMATED SAMPLE PREPARATION INTELLIGENT SYSTEM SOLUTION Food, Feed, Mycotoxin Analysis, Environmental Analysis, Drug Screening, Pharmaceutical Samples FREESTYLE SPE ThermELUTE EVAporation GPC Software

More information

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

GC-xt. The most flexible GC /GC-MS liquid sample injector

GC-xt. The most flexible GC /GC-MS liquid sample injector GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep

More information

Optimize Your Process Operations by Improving Process Monitoring

Optimize Your Process Operations by Improving Process Monitoring Integral Process Ana Optimize Your Process Operations by Improving Process Monitoring All industrial processes have a common need reliable, accurate, and timely methods for analyzing process chemistry.

More information

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction

More information

METHOD 8310 POLYNUCLEAR AROMATIC HYDROCARBONS

METHOD 8310 POLYNUCLEAR AROMATIC HYDROCARBONS METHOD 8310 POLYNUCLEAR AROMATIC HYDROCARBONS 1.0 SCOPE AND APPLICATION 1.1 Method 8310 is used to determine the concentration of certain polynuclear aromatic hydrocarbons (PAH) in ground water and wastes.

More information

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

Protocol: HPLC (amino acids)

Protocol: HPLC (amino acids) Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain

More information

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options Focus XC Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options FOCUS XC AUTOMATED PEPTIDE SYNTHESIZER aapptec s Focus XC is a compact, easy to use fully automated peptide synthesizer

More information

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note. EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

EQuan MAX Getting Connected Field Service Guide

EQuan MAX Getting Connected Field Service Guide EQuan MAX Getting Connected Field Service Guide This guide provides procedures to connect the various components for the Thermo Scientific EQuan MAX automated high-throughput LC-MS system. Contents Hardware

More information

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow TotalChrom Chromatography Data Systems Streamlining your laboratory workflow maximize productivity with TotalChrom CDS Acquiring, processing, reporting, reviewing and approving data is a streamlined series

More information

Determination of Caffeine in Beverages HPLC-1

Determination of Caffeine in Beverages HPLC-1 Determination of in s HPLC-1 Introduction This experiment provides an introduction to the application of High Performance Liquid Chromatography (HPLC) to the solution of complex analytical problems. Cola

More information

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations

More information

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High-Throughput 3-D Chromatography Through Ion Exchange SPE High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample

More information

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE) Application Note 340 Determination of Fat in Dried Milk Products INTRODUCTION Many extraction techniques for the determination of fat in food are labor-intensive or require long extraction times. The Roese-Gottlieb

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,

More information

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation PURIFICATION Preparative Chromatography Modular Solutions from Manual Systems to Full Automation PREPARATIVE CHROMATOGRAPHY SOLUTIONS Lab scale Scale Up Reverse Phase Medicinal Chemistry Natural Products

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for

More information

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free 800 541.

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free 800 541. Product Knowledge Filter Vials PTFE PVDF Nylon PES.2µm.45µm.2µm.45µm.2µm.45µm.2µm.45µm Pat. US #7,790,117 Worldwide patents pending Thomson Instrument Company Toll Free 800 541.4792 Email folks@htslabs.com

More information

Rheodyne Manual Sample Injector Valves

Rheodyne Manual Sample Injector Valves Rheodyne Manual Sample Injector Valves Rotor Seal Shaft End Rotor Seal Groove Stator Face Stator Stator Face Seal Rotor Seal Grooves Position A Rotor Seal Grooves Position B Position C Flow paths showing

More information

Gel Filtration Standard

Gel Filtration Standard Gel Filtration Standard Instruction Manual Catalog # 151-1901 Table of Contents Section 1 Introduction... 1 1.1 Instructions... 1 1.2 Recommended Volume of Standard... 2 1.3 Shelf Life... 5 1.4 Storage...

More information

The GeneAmp PCR System 9700. Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

The GeneAmp PCR System 9700. Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700 The GeneAmp PCR System 9700 Results you can trust. A PCR platform you can grow with. GeneAmp PCR System 9700 The GeneAmp PCR System 9700 fits your lab bench, your applications and your budget. The GeneAmp

More information

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Quantitative Evaluation of Perfume Fleuressence Samples using the znose Quantitative Evaluation of Perfume Fleuressence Samples using the znose Edward J. Staples, Electronic Sensor Technology Electronic Noses Conventional electronic noses (enoses) produce a recognizable response

More information

CyTOF2 Sample Acquisition: Super Sampler* (CyTOF software version 6.0.626)

CyTOF2 Sample Acquisition: Super Sampler* (CyTOF software version 6.0.626) CyTOF2 Sample Acquisition: Super Sampler* (CyTOF software version 6.0.626) *Amended from Sampler Manual created by Zach Bjornson Because CyTOF computer is on a private network, you will be bombarded with

More information

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.

More information

HPLC Basics, Equipment, and Troubleshooting

HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,

More information

Gas Chromatography Liner Selection Guide

Gas Chromatography Liner Selection Guide Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing

More information

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in

More information

MILESTONE H E L P I N G C H E M I S T S

MILESTONE H E L P I N G C H E M I S T S MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the Milestone DMA-80 1. No sample preparation The DMA-80 does not require any sample preparation or other wet chemistry prior the analysis.

More information

Opiates in Urine by SAMHSA GC/MS

Opiates in Urine by SAMHSA GC/MS application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Opiates in Urine by SAMHSA GC/MS Introduction The United States Department of Health

More information

limit to percentage levels, a limited working range translates

limit to percentage levels, a limited working range translates Figure 1. The AutoPrep 50 Automatic Dilution System. Figure 2. Schematic diagram of the AutoPrep 50. Flame atomic absorption spectroscopy (flame AA) is still the most frequently used instrumental technique

More information

Research for leachables of nuclear grade cation exchange resin

Research for leachables of nuclear grade cation exchange resin International Journal of Smart Grid and Clean Energy Research for leachables of nuclear grade cation exchange resin Liang-Cheng Chen, Dah-Yu Kao, Tung-Jen Wen, Ping-Ji Huang Institute of Nuclear Energy

More information

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex

More information

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS D. Loeffler 1, M. Ramil 1, T. Ternes 1, M. Suter 2, R. Schönenberger 2, H.-R. Aerni 2, S, König, A. Besa,

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information

Amino Acid Analyzer L-8900

Amino Acid Analyzer L-8900 Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is

More information

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits Issue Implementation Page 1 of 7 GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits Scope and Application This method will determine the level of vanillin and ethyl vanillin in distilled

More information

NWTPH-HCID. Hydrocarbon Identification Method for Soil and Water

NWTPH-HCID. Hydrocarbon Identification Method for Soil and Water NWTPH-HCID Hydrocarbon Identification Method for Soil and Water Summary This method is a qualitative and semi-quantitative procedure. It is used for groundwater or surface water, and soil/sediment from

More information

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION

More information

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Chapter 28: High-Performance Liquid Chromatography (HPLC) Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion

More information

ChromQuest 5.0 Chromatography Data System

ChromQuest 5.0 Chromatography Data System ChromQuest 5.0 Chromatography Data System User Guide for the Surveyor LC CHROM-97257 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor and ChromQuest are trademarks

More information

Flow Solution Parts & Accessories

Flow Solution Parts & Accessories Flow Solution Parts & Accessories Assemblies Part # Instrument U/M Price Debubbler Debubbler, Acrylic A000172 All ea $140.00 Distillation Coil Heater Spool A515017 FS III/IV ea $495.00 Digestion Coil UV

More information

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax. Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative

More information

DMA-1 Direct Mercury Analyzer

DMA-1 Direct Mercury Analyzer DMA-1 Direct Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the milestone DmA-1 1. no sample preparation 2. ease of use 3. lowest cost of analysis

More information

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,

More information

INTRODUCING THE NEW. Xcelodose S. New Powder Micro-dosing System. Even Faster Time to First in Man

INTRODUCING THE NEW. Xcelodose S. New Powder Micro-dosing System. Even Faster Time to First in Man INTRODUCING THE NEW Xcelodose S New Powder Micro-dosing System Even Faster Time to First in Man Xcelodose S Benefits Even Faster Time to First in Man with precision, speed and accuracy Fills with precision

More information

Innovative vs Traditional

Innovative vs Traditional And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late

More information

Oasis HLB Cartridges and 96-Well Plates

Oasis HLB Cartridges and 96-Well Plates CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION

More information

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac.

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac. SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 i.chianella.1998@cranfield.ac.uk Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation

More information

SM 3300 - Interface modules

SM 3300 - Interface modules Vissersdijk 4 4301 ND Zierikzee The Netherlands Tel. +31 111 413656 Fax. +31 111 416919 www.deltapowersupplies.com DELTA ELEKTRONIKA B.V. SM 3300 - Interface modules Mod els Description INT MOD M/S Master/Slave

More information

Purification of reaction mixtures using flash chromatography.

Purification of reaction mixtures using flash chromatography. Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?

More information

With proper calibration, the upper limit may be extended as needed.

With proper calibration, the upper limit may be extended as needed. While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the

More information

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ)

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ) Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) Closing Date and Time: Wednesday, April 13, 2016 at 5:00 p.m. (Pacific Time) Contact: Aaron Galloway Fax: 541-888-3250

More information

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 ) Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 ) Andrew Aubin Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S Fast analysis of

More information

Flow Injection Analysis

Flow Injection Analysis Flow Injection Analysis Almost all reagent based assays can be downscaled and automated by Flow Injection Analysis. FIA was first described in a patent filed in Denmark by Ruzicka and Hansen in 1974. Since

More information

The Theory of HPLC. Gradient HPLC

The Theory of HPLC. Gradient HPLC The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims

More information

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2

More information

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Analysis of Vegetable Oils by High Performance Liquid Chromatography Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia

More information

On-line Dissolved Gas Analysis

On-line Dissolved Gas Analysis On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully

More information

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory

More information

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation

More information

How To Use An Acquity Qda Detector

How To Use An Acquity Qda Detector Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector

More information

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs Kinet C, De Pauw E, Focant JF CART, Mass Spectrometry Laboratory, Chemistry Department, University of Liège, Allée de la Chimie 3,

More information

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids Willamette University Chemistry Department 2013 Project 5: HPLC Analysis of Capsaicinoids LABORATORY REPORT: Formal Writing Exercises PRE-LAB ASSIGNMENT Read the entire laboratory project and section 28C

More information

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1. Application Note Determination of Amino acids by UHPLC with automated PA- Derivatization by the Autosampler Category Bio Analysis Matrix - Method UHPLC Keywords Proteinogenic Amino acids, Canonical Amino

More information

Product information CHRONOS 4.1

Product information CHRONOS 4.1 Date: April 2014 the universal automation platform for chromatographic analytics Automation is an important topic in chromatographic laboratories. A decrease in the number of personnel and increasing requirements

More information

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory

More information

Fractional Distillation and Gas Chromatography

Fractional Distillation and Gas Chromatography Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils

More information

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic

More information