Bubble CPAP System PRODUCT CATALOGUE

Size: px
Start display at page:

Download "Bubble CPAP System PRODUCT CATALOGUE"

Transcription

1 Bubble CPAP System PRODUCT CATALOGUE

2

3 Bubble CPAP Contents Section Delivery Systems 1 Diagrams 1.1 Infant Delivery System (BC151) 1.2 Infant Delivery System (BC161) 1.2 Infant Delivery System (BC171) 1.2 Patient Interface 2 Nasal Tubing Midline 2.1 Nasal Tubing Universal 2.1 Nasal Prongs 2.1 Infant Bonnet Midline 2.1 Headgear Midline 2.1 Chinstrap 2.1 Bubble CPAP System Starter Kits 3 Starter Kit Midline Delivery System 3.1 Starter Kit I/F (Flow Driver compatible) Delivery System 3.1 Nasal Prong Starter Kit 3.2 Infant Bonnet Starter Kit 3.2 Starter Kit Midline F&P 50mm 3.2 Starter Kit Midline F&P 70mm 3.2 Starter Kit Midline F&P 100mm 3.2 Starter Kit Midline Universal 50mm 3.3 Starter Kit Midline Universal 70mm 3.3 Starter Kit Midline Universal 100mm 3.3 Accessories / Devices 4 Single-Use Gas Supply Line 2.1m 4.1 Gas Supply Line to 2 flow meters 4.1 Midline Pressure Luer Adaptor 4.1 Mounting Options Humidifier Stand Telescopic 4.2 Mounting Bracket C-Clamp 4.2 Mounting Bracket Pole 15-50mm 4.2 Humidification Humidifier 4.3 Heater Wire Adaptor MR Heater Wire/Temp Probe Kit 4.3 Probe Temp/Flow Ang 1600mm 4.3 Gas Supply Bird MBlender 2-16LPM DISS 4.3 Bird MBlender 2-16LPM NIST 4.3 Bird MBlender Pole Mount Bracket 4.3 Sample Setups 5 Pole Mount Setup 5.1 Infant Warmer Setup 5.2

4 Bubble CPAP Delivery Systems 1.1 BC161 BC BC

5 Bubble CPAP Delivery Systems 1.2 MR290 Chamber Product Code BC Includes BC Includes BC171-10* Includes Description Infant Delivery System MR290 chamber Pressure Manifold CPAP Generator Single-heated Circuit Infant Delivery System MR290 chamber Pressure Manifold CPAP Generator Single-heated Circuit Infant Delivery System MR290 chamber Simplified Pressure Manifold (with attached dry line) CPAP Generator Single-heated Circuit Pressure Damping Filter * Flow Driver compatible circuit Pressure Manifold Simplified Pressure Manifold (BC only) Single Heated Circuit Pressure Damping Filter (BC only) CPAP Generator

6 Bubble CPAP Patient Interface 2.1 Length in mm Product Code Description Size Nasal Tubing Midline (BC18x series) Nasal Tubing Universal (BC19x series) Diameter of nares Septum gap Nasal Prongs Nasal Tubing Length BC Nasal tubing 50mm x5 50mm BC Nasal tubing 70mm x5 70mm BC Nasal tubing 100mm x5 100mm BC Nasal tubing Universal 50mm x5 50mm BC Nasal tubing Universal 70mm x5 70mm BC Nasal tubing Universal 100mm x5 100mm Nasal Prongs diameter of nares / width of septum BC Nasal prong /bx 3.0mm / 2.0mm BC Nasal prong /bx 3.5mm / 2.0mm BC Nasal prong /bx 4.0mm / 3.0mm BC Nasal prong /bx 4.5mm / 4.0mm BC Nasal prong /bx 5.0mm / 4.0mm BC Nasal prong /bx 5.0mm / 5.0mm BC Nasal prong /bx 5.5mm / 5.0mm BC Nasal prong /bx 5.5mm / 6.0mm BC Nasal prong /bx 6.0mm / 6.0mm BC Nasal prong /bx 6.0mm / 7.0mm BC Nasal prong /bx 6.5mm / 7.0mm Product Code Description Size Infant Bonnet head circumference BC Infant Bonnet Midline 17-22cm x5 17cm-22cm BC Infant Bonnet Midline 22-25cm x5 22cm-25cm BC Infant Bonnet Midline 25-29cm x5 25cm-29cm BC Infant Bonnet Midline 29-36cm x5 29cm-36cm Infant Bonnet Product Code Description Size Headgear head circumference BC Headgear Midline 29-36cm x5 29cm-36cm BC Headgear Midline 35-40cm x5 35cm-40cm BC Headgear Midline 40-45cm x5 40cm-45cm Headgear Chinstrap face circumference BC Chinstrap 20-26cm x10 20cm-26cm BC Chinstrap 26-32cm x10 26cm-32cm BC Chinstrap 32-38cm x10 32cm-38cm BC Chinstrap 38-44cm x10 38cm-44cm Chinstrap

7 Bubble CPAP Bubble CPAP System Starter Kits 3.1 Product Code Description Simplified Pressure Manifold (BC171 only) Infant Bonnet Nasal Tubing Nasal Prongs Damping Filter (BC171 only) BC461-SK Includes Starter Kit Midline Delivery System 5 BC161 Infant Delivery System 5 Nasal tubing 70mm 2 Infant Bonnet 17-22cm 3 Infant Bonnet 22-25cm 3 Infant Bonnet 25-29cm 2 Infant Bonnet 29-36cm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong 6070 BC471-SK* Starter Kit I/F Delivery System Includes 5 BC171 Infant Delivery System (with simplified pressure manifold and pressure damping filter) 5 Nasal tubing 70mm 2 Infant Bonnet 17-22cm 3 Infant Bonnet 22-25cm 3 Infant Bonnet 25-29cm 2 Infant Bonnet 29-36cm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong 6070 * Flow Driver compatible circuit Infant Flow compatible circuit CPAP Generator Pressure Manifold MR290 Chamber

8 Bubble CPAP Patient Interface Starter Kits 3.2 Product Code Description Nasal Prongs BC260-SK Nasal Prong Starter Kit Includes 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong Nasal Prong 6070 Infant Bonnet Nasal Tubing BC360-SK Infant Bonnet Starter Kit Includes 2 Infant Bonnet 17-22cm 3 Infant Bonnet 22-25cm 3 Infant Bonnet 25-29cm 2 Infant Bonnet 29-36cm BC480-SK Starter Kit Midline F&P 50mm Includes 3 Nasal tubing 50mm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Infant Bonnet 17-22cm 2 Infant Bonnet 22-25cm 1 Infant Bonnet 25-29cm BC481-SK Starter Kit Midline F&P 70mm Includes 3 Nasal tubing 70mm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Infant Bonnet 17-22cm 2 Infant Bonnet 22-25cm 1 Infant Bonnet 25-29cm BC482-SK Starter Kit Midline F&P 100mm Includes 3 Nasal tubing 100mm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Infant Bonnet 22-25cm 2 Infant Bonnet 25-29cm 1 Infant Bonnet 29-36cm

9 Bubble CPAP Universal Patient Interface Starter Kits 3.3 The Universal Patient Interface Starter Kit is designed to allow connection of other single-heated circuits e.g. Cardinal and Hudson. Product Code Description Nasal Tubing BC490-SK Starter Kit Midline Universal 50mm Includes 3 Nasal Tubing Universal 50mm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Infant Bonnet 17-22cm 2 Infant Bonnet 22-25cm 1 Infant Bonnet 25-29cm Nasal Prongs BC491-SK Starter Kit Midline Universal 70mm Includes 3 Nasal Tubing Universal 70mm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Infant Bonnet 17-22cm 2 Infant Bonnet 22-25cm 1 Infant Bonnet 25-29cm Infant Bonnet BC492-SK Starter Kit Midline Universal 100mm Includes 3 Nasal Tubing Universal 100mm 2 Nasal Prong Nasal Prong Nasal Prong Nasal Prong Infant Bonnet 22-25cm 2 Infant Bonnet 25-29cm 1 Infant Bonnet 29-36cm

10 Bubble CPAP Accessories 4.1 Single-Use Product Code Description Gas Supply Line (to blender) BC Gas Supply Line 2.1m BC Gas Supply Line (to 2 flow meters) BC Midline Pressure Luer Adaptor Gas Supply Line (to 2 flow meters) Midline Pressure Luer Adaptor

11 Bubble CPAP Mounting Options 4.2 Product Code 900MR MR MR030 Description Humidifier Stand telescopic Mounting Bracket C-clamp Mounting Bracket Pole 15-50mm Telescopic Humidifier Stand C-Clamp Pole Clamp

12 Bubble CPAP Devices 4.3 Humidification Product Code MR MR MR MR868 Description Humidifier Heater Wire Adaptor MR850 Heater Wire/Temp Probe Kit Probe Temp/Flow Ang 1600mm MR850 Humidifier Temperature / Flow Probe Heater Wire Gas Supply Low Flow Air/O2 Blender Product Code BC BC BC BC BC Description Bird MBlender 2-16LPM DISS Bird MBlender 2-16LPM NIST Blender Oxy/Air Bio-Med (DISS) green Blender Oxy/Air Bio-Med (DISS) white Bird MBlender Pole Mount Bracket Bird MBlender Pole Mount Bracket Blender DISS & NIST fittings available BIO-MED DEVICES O 2% Gas Blenders are available on an individual basis. They come complete with color coded nipples and control knobs. Flowrate 2-16 L/min (Bird) 0-15 L/min (Bio-Med) Includes flowmeter nipples (green or white) Note: Requires 900IW320 Bird Bracket Blender Complete to be fitted to the CosyCot Infant Warmer. Gas hoses not included. Please refer to Fisher & Paykel Healthcare Infant Warming Catalogue.

13 Bubble CPAP Sample Setup (pole) 5.1 Bird MBlender 2-16LPM BC (DISS) BC (NIST) Low Flow Air/O2 Blender Note: Gas Hoses not included. Please refer to Fisher & Paykel Infant Warming Catalogue BC Bird MBlender Pole Mount Bracket MR850 Humidifier 900MR801 Heater Wire Adaptor MR MR030 Mounting Bracket Pole 15-50mm (for mounting humidifier) 900MR868 Probe Temp/Flow Ang 1600mm 900MR170 Mounting Bracket C-Clamp (for mounting CPAP generator) 900MR292 Humidifier Stand Telescopic

14 Bubble CPAP Sample Setup (warmer) 5.2 Low Flow Air/O2 Blender Bird MBlender 2-16LPM BC (DISS) BC (NIST) Note: Gas Hoses not included. Please refer to Fisher & Paykel Infant Warming Catalogue BC Bird MBlender Pole Mount Bracket MR850 Humidifier 900MR030 Mounting Bracket Pole 15-50mm (for mounting humidifier) 900MR801 Heater Wire Adaptor MR MR868 Probe Temp/Flow Ang 1600mm 900IW302 Mounting Pole long 900MR170 Mounting Bracket C-Clamp (for mounting CPAP generator)

15

16 MANUFACTURER Fisher & Paykel Healthcare Limited, 15 Maurice Paykel Place, East Tamaki, Auckland 2013; P O Box , Panmure, Auckland 1741, New Zealand Tel: Fax: info@fphcare.com Web Site: AUSTRALIA Tel: Fax: AUSTRIA Tel: Fax: BENELUX Tel: Fax: CHINA Tel: Fax: FRANCE Tel: Fax: GERMANY Tel: Fax: INDIA Tel: Fax: IRISH REPUBLIC Tel: ITALY Tel: Fax: JAPAN Tel: Fax: NORTHERN IRELAND Tel: SPAIN Tel: Fax: SWEDEN Tel: Fax: SWITZERLAND Tel: Fax: UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, United Kingdom Tel: Fax: USA Tel: or Fax: REF Rev F en

17 Bubble CPAP System Set-up Guide

18 For full User Instructions, please refer to Bubble CPAP System User Instructions (BC151/BC161 PN and BC171 PN ).

19 BC151 / BC161 BC161 (connects to F&P FlexiTrunk Interface) BC151 (connects to T-bar Interface) Checks During Operation Regularly observe that the water is feeding into the humidification chamber. Should the water level exceed the maximum level marked on the humidification chamber, the chamber should be replaced. Check that all connections are tight before use and after any adjustment. Ensure air flow is present at all times. If air flow is interrupted, turn off the humidifier. Regularly observe the circuit for condensate. Drain as required. Regularly observe the CPAP generator for bubbling. If bubbling is not observed, check for and minimize air leaks in the system and at the patient. If air leaks have been minimized, air flow may be increased to achieve continuous bubbling. Regularly observe the water level in the CPAP generator and overflow container. Refill the CPAP generator if the water level drops below the minimum water level line. Check and empty the overflow container once every 8 hours or as needed. Monitor patient oxygen levels. Always use pressure monitoring to verify that the patient is receiving the prescribed CPAP level. F & P b u b b l e c p a p s e t - u p G u i d e 1

20 BC151 / BC161 SET-UP 1. Insert Humidification Chamber Discard the chamber if the seals are not intact when received. Slide the chamber on to the humidifier base. Remove the blue caps. 2. Connect Water Bag Hang the water bag, unwind the water feed set and spike the water bag. Open the vent on the vented spike. Check the humidification chamber for water flow from the bag. If no water is visible in the chamber or water consumption is low, check that the bag is spiked properly and that the feed tube is not kinked or blocked. Try gently squeezing the bag to promote water flow. Ensure that the height of the water bag is at least higher than the humidification chamber. If in doubt replace the chamber. Discard the chamber if the water level exceeds the maximum water level line. 3. Fill Bubble CPAP Generator Using the fill-funnel provided, fill the CPAP generator with sterile water until water flows into the overflow container. Set the CPAP probe to 10 cmh 2 O, ready for the leak test. Ensure that the fill-funnel remains on the Bubble CPAP generator. Ensure that the humidifier and Bubble CPAP generator are mounted below the patient. Water level too low Water level correct 2 F & P b u b b l e c p a p s e t - u p G u i d e

21 4. Connect Bubble CPAP Pressure Manifold and Breathing Circuit Connect the oxygen tubing between the pressure manifold and the flow source. Connect the pressure manifold to the chamber inlet port. Connect the blue inspiratory tube to the remaining chamber port. Remove the blue caps from the inspiratory tube and install the temperature probe ports and heaterwire adapter. Ensure that the heater-wire (inside tube) is evenly distributed along the circuit length and is not bunched or kinked. Connect test elbow to expiratory and inspiratory limbs. 1 L/min Leak Test Check all connections are tight before use. Set the CPAP probe to 10 cmh 2 O and the input flow rate to 1 L/min. Observe the CPAP generator. Gentle, audible bubbling is acceptable; no bubbling means unacceptable leakage. If no bubbling is observed, check the entire system. Remove the correct port cap from the pressure manifold before connecting any monitoring device. 6-8 L/min (<15 L/min) 6. Set Flow Rate Adjust the flow rate to the prescribed input flow rate. Recommended flow rate: 6 to 8 L/min. Allowable flow range: 4 to 15 L/min. F & P b u b b l e c p a p s e t - u p G u i d e 3

22 BC151 / BC161 SET-UP Pressure-Flow Table F&P Bubble CPAP Generator used with F&P Infant Interface, typical mean pressure values (cmh 2 0) WITH NO LEAK Probe Setting (cmh 2 O) Flow (L/min) Note: Other interfaces or circuits may produce varying pressures Set CPAP Level The number on the CPAP probe above the lid indicates the CPAP pressure in cmh 2 O. As an example, the illustration shows CPAP setting of 6 cmh 2 O. Set the CPAP probe at the prescribed level (3 to 10 cmh 2 O). 4 F & P b u b b l e c p a p s e t - u p G u i d e

23 8. Connect Bubble CPAP Circuit to Infant Interface Remove the flow test elbow and connect the circuits to the Infant Interface using the instructions provided with the interface. BC161 connects to F&P FlexiTrunk Interface. BC151 connects to short binasal prongs (T-bar). MR850: 37 C 9. Set the Humidifier Ensure there is air flow present before turning on the humidifier. Turn on the humidifier. If using the MR850, ensure it is on Invasive mode (37 C). If using the MR730, set the temperature to 40 C, -3. Refer to the MR850 or MR730 User Instructions for further information. MR730: 40 C, Attach Interface to Infant Connect the interface to the infant using the instructions provided with the interface. BC161 BC151 F & P b u b b l e c p a p s e t - u p G u i d e 5

24 BC171 BC171 (connects to Flow Driver) Checks During Operation Regularly observe that the water is feeding into the humidification chamber. Should the water level exceed the maximum level marked on the humidification chamber, the chamber should be replaced. Check all connections are tight before use and after any adjustment. Ensure air flow is present at all times. If air flow is interrupted, turn off the humidifier. Regularly observe the circuit for condensate. Drain as required. Regularly observe the CPAP generator for bubbling. If bubbling is not observed, check for and minimize air leaks in the system and at the patient. If air leaks have been minimized, air flow may be increased to achieve continuous bubbling. Regularly observe the water level in the CPAP generator and overflow container. Refill the CPAP generator if the water level drops below the minimum water level line. Check and empty the overflow container once every 8 hours or as needed. Monitor patient oxygen levels. Always use pressure monitoring to verify that the patient is receiving the prescribed CPAP level. 6 F & P b u b b l e c p a p s e t - u p G u i d e

25 BC171 SET-UP 1. Insert Humidification Chamber Discard the chamber if the seals are not intact when received. Slide the chamber on to the humidifier base. Remove the blue caps. 2. Connect Water Bag Hang the water bag, unwind the water feed set and spike the water bag. Open the vent on the vented spike. Check the humidification chamber for water flow from the bag. If no water is visible in the chamber or water consumption is low, check that the bag is spiked properly and that the feed tube is not kinked or blocked. Try gently squeezing the bag to promote water flow. Ensure that the height of the water bag is at least 50 cm higher than the humidification chamber. If in doubt replace the chamber. Discard the chamber if the water level exceeds the maximum water level line. 3. Fill Bubble CPAP Generator Using the fill-funnel provided, fill the CPAP generator with sterile water until water flows into the overflow container. Set the CPAP probe to 10 cmh 2 O, ready for the leak test. Ensure that the fill-funnel remains on the Bubble CPAP generator. Ensure that the humidifier and Bubble CPAP generator are mounted below the patient. Water level too low Water level correct F & P b u b b l e c p a p s e t - u p G u i d e 7

26 BC171 SET-UP 4. Connect Pressure Manifold, Dry Line and Circuit Connect the pressure manifold with dry line to the flow driver and chamber inlet port. Connect the blue inspiratory limb to the remaining chamber port. Remove the blue caps from the inspiratory tube and install the temperature probe ports and the heaterwire adapter. Ensure that the heater wire is evenly distributed along the circuit length and is not bunched or kinked. Connect test elbow to expiratory and inspiratory limbs. 1 L/min Leak Test Check all connections are tight before use. Set the CPAP probe to 10 cmh 2 O and the input flow rate to 1 L/min. Observe the CPAP generator. Gentle, audible bubbling is acceptable; no bubbling means unacceptable leakage. If no bubbling is observed, check the entire system. 6. Set Flow Rate Adjust the flow rate to the prescribed input flow rate. Recommended flow rate: 6 to 8 L/min. Allowable flow range: 4 to 15 L/min. 6-8 L/min (<15 L/min) Set CPAP Level The number on the CPAP probe above the lid indicates the CPAP pressure in cmh 2 O. As an example, the illustration shows CPAP setting of 6 cmh 2 O. Set the CPAP probe at the prescribed level (3 to 10 cmh 2 O). 8 F & P b u b b l e c p a p s e t - u p G u i d e

27 Pressure-Flow Table F&P Bubble CPAP Generator used with F&P Infant Interface, typical mean pressure values (cmh 2 0) WITH NO LEAK Probe Setting (cmh 2 O) Flow (L/min) Note: Other interfaces or circuits may produce varying pressures. 7. Connect Bubble CPAP Circuit to Infant Interface Remove the flow test elbow and connect the circuits to the Infant Interface using the instructions provided with the interface. F & P b u b b l e c p a p s e t - u p G u i d e 9

28 BC171 SET-UP 8. Connect Pressure Line to Flow Driver Connect the pressure line filter end of the pressure line to the flow driver. Connect the pressure line elbow connector end of the pressure line to the nasal tubing pressure port. 9. Set the Humidifier (MR850) Ensure there is air flow present before turning on the humidifier. Turn on the flow driver. Turn on the humidifier. If using the MR850, ensure it is on Invasive mode (37 C). Refer to the MR850 User Instructions for further information. MR850: 37 C A 9A. Set the Humidifier (MR730) Ensure there is air flow present before turning on the humidifier. Turn on the flow driver. Turn on the humidifier. If using the MR730, set the temperature to 40 C, -3. Refer to the MR730 User Instructions for further information. MR730: 40 C, F & P b u b b l e c p a p s e t - u p G u i d e

29 10. Attach Interface to Infant Connect the interface to the infant using the instructions provided with the interface. BC171 F & P b u b b l e c p a p s e t - u p G u i d e 1 1

30 For more information please contact your local Fisher & Paykel Healthcare representative REVa EN 2011 Fisher & Paykel Healthcare Limited Manufacturer Fisher & Paykel Healthcare Ltd 15 Maurice Paykel Place East Tamaki, Auckland 2013 PO Box , Panmure Auckland 1741 New Zealand Tel: Fax: info@fphcare.com Web: Australia Fisher & Paykel Healthcare Pty Limited New Street, PO Box 167 Ringwood, Melbourne Victoria 3134, Australia Tel: Fax: Austria Tel: Fax: Benelux Tel: Fax: China Tel: Fax: France Tel: Fax: Germany Tel: Fax: India Tel: Fax: Irish Republic Tel: Italy Tel: Fax: Spain Tel: Fax: Sweden Tel: Fax: Switzerland Tel: Fax: Taiwan Tel: Fax: Turkey Tel: Fax: UK EC REP Fisher & Paykel Healthcare Ltd Unit 16, Cordwallis Park Clivemont Road, Maidenhead Berkshire SL6 7BU, UK Tel: Fax: USA/Canada Tel: or Fax:

31 Bubble CPAP System F&P Bubble CPAP SYSTEM With the goal of improving patient care in over 120 countries, Fisher & Paykel Healthcare designed the F&P Bubble CPAP System for use with spontaneously breathing infants requiring respiratory support. Incorporating unique features and world-leading humidification technology, the F&P Bubble CPAP System has been developed to provide a respiratory support system that is safe, effective and easy to use. Adaptability to current practices has been taken into consideration with the choice of various system models. The F&P Infant Interface complements the system, providing comfort and optimum CPAP support to the infant at risk.

32 F&P Bubble CPAP System FEATURES The F&P Bubble CPAP System is the first complete system available in an All-in-One Pack. It includes the Bubble CPAP generator, heated breathing circuits, humidification chamber and pressure manifold. F&P FlexiTrunk is a lightweight nasal tubing with a unique, flexible extension for a stable prong and mask fixation while allowing for normal infant movement. F&P Bubble CPAP System models include: BC151 connects to other infant CPAP interfaces (e.g. Hudson and Inca prongs) BC161 connects to the F&P Infant Interface BC171 connects to the M672P Infant Flow Driver (IFD) or equivalent BC161 BC171 BC Safe and Reliable Used on over a quarter of a million patients globally The unique auto-level mechanism of the Bubble CPAP generator provides consistent and accurate delivery of CPAP The pressure manifold with pressure relief valve promotes infant safety Easy to Use Easy auto-leveling by simply adding water into the Fill Funnel on the Bubble CPAP generator Excess condensate automatically drains into the detachable overflow container (see image on right) Detachable overflow container can be emptied without interrupting CPAP Optimum Humidification The F&P Bubble CPAP System provides respiratory support with body-temperature pressure-saturated gases to the infant Optimal humidity promotes mucociliary clearance and reduces the work of breathing Simple Yet Versatile Adjustable CPAP from 3 to 10 cmh 2 O The Bubble CPAP System can connect to various interfaces

33 FOCUS ON FEATURES Bubble CPAP Circuit Spiral heater-wire provides even heat distribution, reducing heat loss and condensate build-up Aims to deliver optimal humidity Bubble CPAP Pressure Manifold Limits the pressure delivered in the event of an occlusion Allows connection to a pressuremonitoring device and/or an air/oxygen analyzer MR290 Humidification Chamber Auto-fill, easy to use Maintains constant CPAP Closed system minimizes the risk of infection Bubble CPAP Generator Adjustable CPAP from 3 to 10 cmh2o Detachable overflow container allows uninterrupted CPAP when overflow container is being emptied Includes separate Fill Funnel Mounting bracket is incorporated on the back of the Bubble CPAP generator

34 F&P Bubble CPAP System SPECIFICATIONS F&P Bubble CPAP System Input Flow Range Recommended Input Flow Set CPAP Pressure Range Intended Patient Population Operating Temperature Range Storage Temperature Range Usage Period Maximum Pressure Limit Oxygen Analyzer Port 4 to 15 L/min 6 to 8 L/min 3 to 10 cmh 2 O Premature neonates and infants up to 10 kg 18 to 26 o C -10 to 50 o C Single patient use, for a maximum of 7 days 17 cmh 2 8 L/min 22 mm Male or 15 mm Female Pressure Monitoring Port Respiratory Humidifier Female luer F&P MR850 or MR730 only (Invasive Mode) Circuit Length Inspiratory Tube Expiratory Tube BC m (3.61 ft) 1.2 m (3.94 ft) BC m (4.59 ft) includes 300 mm (11.8 in) extension to connect to Hudson Prongs 1.2 m (3.94 ft) BC m (3.61 ft) 1.2 m (3.94 ft) F&P Bubble cpap system models Product Code & Description BC151* BC161* EN Rev B 2012 Fisher & Paykel Healthcare Limited BC171* * Box of 10 Note: For ordering information, please refer to the Fisher &Paykel Healthcare Bubble CPAP Product Catalogue (Part No ). MR850 Humidifier must be purchased separately. Manufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box , Panmure, Auckland 1741, New Zealand Tel: Fax: info@fphcare.co.nz Web: Australia Tel: Fax: Austria Tel: Fax: Benelux Tel: Fax: China Tel: Fax: France Tel: Fax: Germany Tel: Fax: India Tel: Fax: Irish Republic Tel: Italy Tel: Fax: Japan Tel: Fax: Northern Ireland Tel: Spain Tel: Fax: Sweden Tel: Fax: Switzerland Tel: Fax: Taiwan Tel: Fax: Turkey Tel: Fax: UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, UK Tel: Fax: USA Tel: or Fax:

1. Overview... A - 2. Intended Use... A - 2. Warnings... A - 2. AIRVO 2 and Accessories... A - 3. 2. Setting up AIRVO 2... A - 4

1. Overview... A - 2. Intended Use... A - 2. Warnings... A - 2. AIRVO 2 and Accessories... A - 3. 2. Setting up AIRVO 2... A - 4 User Manual AIRVO 2 BEFORE YOU START This User Manual is intended for healthcare professionals. This User Manual applies to AIRVO 2 units with LOT numbers 130621 and above. Read this User Manual including

More information

MR850 RESPIRATORY HUMIDIFIER

MR850 RESPIRATORY HUMIDIFIER MR850 RESPIRATORY HUMIDIFIER Technical Manual REVISION J Copyright 2005 Fisher & Paykel Healthcare Ltd. Auckland, New Zealand Fisher & Paykel Healthcare Head Office: PO Box 14-348, Panmure, Auckland 1134

More information

PROCEDURE FOR USING A NASAL CANNULA

PROCEDURE FOR USING A NASAL CANNULA PROCEDURE FOR USING A NASAL CANNULA A nasal cannula is used to deliver a low to moderate concentration of oxygen. It can be used as long as nasal passages are open. A deviated septum, swelling of the nasal

More information

Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation!

Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation! CPAP Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation! Advantages:. Can be worn for any duration without discomfort-no uncomfortable

More information

PLEUR EVAC CHEST DRAINAGE SYSTEMS. Great Innovations to Enhance Chest Drainage

PLEUR EVAC CHEST DRAINAGE SYSTEMS. Great Innovations to Enhance Chest Drainage PLEUR EVAC CHEST DRAINAGE SYSTEMS Great Innovations to Enhance Chest Drainage 2 INTRODUCTION Teleflex Great Innovations to Enhance Chest Drainage Trusted brands make Teleflex a reliable and strong partner.

More information

PROCEDURE FOR USING A NASAL CANNULA

PROCEDURE FOR USING A NASAL CANNULA FOR USING A NASAL CANNULA A nasal cannula is used to deliver a low to moderate concentration of oxygen. It can be used as long as nasal passages are open. A deviated septum, swelling of the nasal passages,

More information

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home. For every breath he takes Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home. Sensitive to your patients needs Trilogy200, a portable life-support

More information

Covering the Spectrum

Covering the Spectrum Warming Unit / Model 24500 Setpoint temperature: 41 C Alarms (audible & visible): - Over-temperature primary setpoint = 43 C - Over-temperature secondary setpoint = 46 C Device rating: 110-120 VAC / 220-240

More information

Trilogy accessory guide

Trilogy accessory guide Trilogy accessory guide 2 Trilogy accessory guide Light, versatile, and easy to use, Trilogy portable life-support ventilators are designed for use in the home and alternative care sites and provide noninvasive

More information

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up Trilogy200 Proximal pressure line Exhalation valve line Quick start guide 1 2 3 4 Overview Circuit set-up Set-up screen Prescription set-up 1 Overview 4 Porting block Detachable battery Air inlet and grey

More information

Ventilators/Transport*

Ventilators/Transport* Ventilators/Transport* pneuton A (Pneumatic Transport Ventilator) pneuton (pronounced new ton ); a small, lightweight transport ventilator designed for use on patients from pediatric to adult in size.

More information

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Operating Instructions & Maintenance Guidelines for Precision Vaporizers Operating Instructions & Maintenance Guidelines for Precision Vaporizers This page intentionally blank. Examination and Preparation for Use We want you to be completely satisfied with your vaporizer. Please

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353. Instruction Manual. Page 1 of 9

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353. Instruction Manual. Page 1 of 9 SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353 Instruction Manual Page 1 of 9 TABLE OF CONTENTS Introduction...3 Important Safeguards..3 System Components...5 Setup and Operation...5 Setup...5 Operation....6

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

ACCESSORIES OXYGEN-THERAPY

ACCESSORIES OXYGEN-THERAPY OXYGEN-THERAPY English version 11/ 2010 HUMIDIFIERS The humidifier is used to humidify the oxygen or the medical air delivered to the patient through the respiratory tract. Screwed to the outlet of a flowmeter

More information

Compliance. Maximizer R ELEASE 1.12

Compliance. Maximizer R ELEASE 1.12 Compliance Maximizer R ELEASE 1.12 C o n t e n t s Page 1 Page 2 INTRODUCTION SYSTEM SETUP System Requirements Warnings Installing Compliance Maximizer Personalizing Compliance Maximizer 2 2 3 4 Homecare

More information

RTM3 OXYGEN-THERAPY FLOWMETERS WITH FLOATING BALL

RTM3 OXYGEN-THERAPY FLOWMETERS WITH FLOATING BALL RTM3 OXYGEN-THERAPY FLOWMETERS WITH FLOATING BALL English version 11/ 2010 OXYGEN-THERAPY RAIL MOUNTING SYSTEMS AFNOR rail mounting systems BS rail mounting systems (neutral) DIN rail mounting systems

More information

ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use. ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use. Version 2 Last Updated 06 November 2015 Table of Contents INTRODUCTION 1.

More information

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010 DEBSON TM2 MORE SAFETY GAS FLOW BETWEEN TWO POSITION English version 11/ 2 010 RAIL MOUNTING SYSTEMS AFNOR rail mounting systems BS rail mounting systems (neutral) DIN rail mounting systems OHMEDA rail

More information

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown) Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

POLICIES & PROCEDURES. ID Number: 1115

POLICIES & PROCEDURES. ID Number: 1115 POLICIES & PROCEDURES Title: OXYGEN ADMINISTRATION ID Number: 1115 Authorization [X] SHR Nursing Practice Committee Source: Nursing, Respiratory Therapy, Physiotherapy Date Revised: March 2015 Date of

More information

Gastrostomy Feeding CARE GUIDELINES FOR PATIENTS & CARERS. Accessory items. Freka UK Funnel Adapter. Fixation Plate CH9. Male Luer Lock Adapter

Gastrostomy Feeding CARE GUIDELINES FOR PATIENTS & CARERS. Accessory items. Freka UK Funnel Adapter. Fixation Plate CH9. Male Luer Lock Adapter Accessory items Freka UK Funnel Adapter Fixation Plate CH9 Code: 7755681 Code: 7903002 Male Luer Lock Adapter CH9 Fixation Plate CH15 Code: 7981311 Code: 7904002 Male Luer Lock Adapter CH15 Code: 798137Y

More information

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES The Gold Standard Cardiovascular QUADROX PLS and ROTAFLOW 3 QUADROX PLS AND ROTAFLOW INNOVATIVE PERFORMANCE AND RELIABILITY

More information

Home Ventilator. 2009 Breath of Life Home Medical Equipment and Respiratory Services

Home Ventilator. 2009 Breath of Life Home Medical Equipment and Respiratory Services Home Ventilator 2009 Breath of Life Home Medical Equipment and Respiratory Services 1 Your Prescription Your physician has prescribed a home ventilator system for your child. This book will help you to

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Knowing the functions of the anesthetic delivery system

More information

TUBING LEADER IN FLUID MANAGEMENT

TUBING LEADER IN FLUID MANAGEMENT TUBING LEADER IN FLUID MANAGEMENT Fluid Administration Sets Fluid administration is a critical part of nearly every procedure. Merit Medical offers a broad selection of fluid management products, ranging

More information

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA. REF. 10049600 Rev. L

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA. REF. 10049600 Rev. L REF. 10049600 Rev. L Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA TABLE OF CONTENTS WARNINGS 2 DESCRIPTION AND MECHANICAL ASSEMBLY 2 CONNECTION

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS Rev.01.02 BIGAS INTERNATIONAL AUTOGAS SYSTEMS S.r.l. Via di Le Prata, 62/66-50041 Calenzano Firenze ITALY Tel. 0554211275 - Fax 0554215977 http: www.bigas.it

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

Mirage FX NASAL MASK. User Guide

Mirage FX NASAL MASK. User Guide Mirage FX NASAL MASK User Guide Mirage FX NASAL MASK Fitting// 1 2 3 4 5 6 Mirage FX i Removal// 1 2 Disassembly// 1 2 3 ii Reassembly// 1 2 3 4 iii Mirage FX A 2 3 1 4 7 6 5 B iv Mask components// Item/

More information

ClearView 100. Instruction Manual

ClearView 100. Instruction Manual ClearView 100 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that they do

More information

For over 40 years, the leader in. nitrous oxide. equipment technology.

For over 40 years, the leader in. nitrous oxide. equipment technology. Conscious Sedation Delivery Systems For over 40 years, the leader in nitrous oxide equipment technology. Made in U.S.A. Over 40 years ago Fraser Sweatman pioneered the technology used for safe delivery

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

www.respironics.com CPAP System User Manual 1007167 LK 5/12/01

www.respironics.com CPAP System User Manual 1007167 LK 5/12/01 www.respironics.com CPAP System User Manual 1007167 LK 5/12/01 Table of Contents Symbol Key... 2 Intended Use... 3 Specifications... 4 Warnings & Cautions... 5 Unpacking the System... 6 System Features...

More information

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate Cooling Rewarming 1 2 3 Always operate in Automatic Mode 1. Turn device on at back of machine 2. Connect pads 3. Connect temperature probe 4. While in STOP Mode, Press DOWN arrow once to reach Target Temp-

More information

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com MEDICAL SYSTEMS Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both

More information

Please keep these operating instructions in a safe place.

Please keep these operating instructions in a safe place. Please keep these operating instructions in a safe place. Dear Customer: Check this product for visible damage immediately upon receipt. Inform the shipper if there is any shipping damage. Note that damage

More information

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens Molecular Imager Gel Doc XR+ Installation Guide To install your Gel Doc XR+, perform these seven steps in the following order: 1. Unpack the Gel Doc XR+ system. 2. Install Image Lab software. 3. Set up

More information

Table of Contents. REMstar Auto User Manual 1

Table of Contents. REMstar Auto User Manual 1 Table of Contents Symbol Key... 2 Intended Use & Contraindications... 3 Specifications... 4 Warnings & Cautions... 5 System Features... 7 First Time Setup... 8 Installing the Filter... 9 Device Settings...

More information

QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus. Operating Manual

QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus. Operating Manual QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus Operating Manual Table of Contents 1 General... 2 1.1 Purpose... 2 1.2 Description... 2 2 Operation... 3 2.1 Pre-donning Inspection... 3 2.1.1

More information

Reverse Cycle Inverter Split System Air Conditioner

Reverse Cycle Inverter Split System Air Conditioner Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

FILLING AND PURGING THE SYSTEM

FILLING AND PURGING THE SYSTEM FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation

More information

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION ENTERAL NUTRITION Freka Enteral Feeding Tube Product Range Fresenius Kabi Limited, Cestrian Court, Eastgate Way, Runcorn, Cheshire WA7 1NT tel: 01928 533533 fax: 01928 533520 email: nutrition.service@fresenius-kabi.com

More information

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/ CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------

More information

Infant Flow SiPAP. Operator s Manual

Infant Flow SiPAP. Operator s Manual Infant Flow SiPAP Operator s Manual ii Infant Flow SiPAP This document is protected by United States and International Copyright laws. This document may not be copied, reproduced, translated, stored in

More information

1. Introduction...1 1.1 Revision History...1. 2. Warnings, Cautions, Contraindictions...2 2.1 Contraindications...2 2.2 Warnings...2 2.3 Cautions...

1. Introduction...1 1.1 Revision History...1. 2. Warnings, Cautions, Contraindictions...2 2.1 Contraindications...2 2.2 Warnings...2 2.3 Cautions... Technical Manual TABLE OF CONTENTS 1. Introduction...1 1.1 Revision History...1 2. Warnings, Cautions, Contraindictions...2 2.1 Contraindications...2 2.2 Warnings...2 2.3 Cautions...3 3. Specifications...4

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

BiPAP Pro Bi-Flex USER MANUAL

BiPAP Pro Bi-Flex USER MANUAL BiPAP Pro Bi-Flex USER MANUAL 2012 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Important... 2 Warnings... 2 Cautions... 3 Contraindications... 3 Symbol

More information

Proportional Relief Valves

Proportional Relief Valves www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to psig (0.7 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves Spring

More information

ReadyKart Mobile Processing Station Instructions for Use

ReadyKart Mobile Processing Station Instructions for Use GE Healthcare Instructions 28-9606-47 AB ReadyKart Mobile Processing Station Instructions for Use Contents ReadyToProcess 1 Introduction... 1 2 General Description... 2 3 Description of Components... 4

More information

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Iron Air Charge 2510-SXT Installation & Start-Up Guide Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water

More information

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use GE Healthcare Instructions 28-9226-84 AD ReadyToProcess Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use 1 Introduction... 1 2 Inspect the Cartridge... 1 3 General Description... 2 4

More information

I have sleep apnea. Now what? A guide to getting the most out of your treatment

I have sleep apnea. Now what? A guide to getting the most out of your treatment I have sleep apnea. Now what? A guide to getting the most out of your treatment Equipment replacement schedule To get the most benefit from your PAP therapy, your equipment should be replaced when necessary

More information

Installation & Operating Instructions

Installation & Operating Instructions MANEP08082011 Installation & Operating Instructions Note: Please read this manual thoroughly before installation and operation Thank you for purchasing your new EazyPod filter. We are sure you will be

More information

System One Heated Humidifier USER MANUAL

System One Heated Humidifier USER MANUAL System One Heated Humidifier USER MANUAL 2011 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Warnings... 2 Cautions... 2 Contraindications... 3 Symbol Key...

More information

NEONATAL INTENSIVE CARE UNIT - ACCESSORIES & CONSUMABLES

NEONATAL INTENSIVE CARE UNIT - ACCESSORIES & CONSUMABLES INTENSIVE CARE UNIT - & CONSUMABLES AccESSORIES CATALOGUE 205 INTENSIVE CARE UNIT & ConsumabLES Babylog VN500 Babylog 8000 Isolette 8000 C2000 0 02 03 04 Caleo Resuscitaire Babytherm 8004/800 TI500 Transport

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00 Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series

More information

Installation Instructions

Installation Instructions VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling

More information

THERAPY SYSTEMS Therapy Systems

THERAPY SYSTEMS Therapy Systems Therapy Systems CPAP Therapy REMstar Plus M Series with C-Flex Offers optional integrated humidification, optional Encore Pro SmartCard capability for basic compliance reporting, therapy meter display,

More information

Critical Care Therapy and Respiratory Care Section

Critical Care Therapy and Respiratory Care Section Category: Section: Title: Critical Care Therapy and Respiratory Care Section Policy #: 03 Revised: 5/02 1.0 DESCRIPTION Clinical Ventilator Management Invasive and Noninvasive Positive Pressure Ventilation

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

INSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

INSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) INSTALLATION INSTRUCTIONS 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) Thank you for purchasing a quality Hellwig Product. PLEASE

More information

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)

More information

53403500 - Injector Max Machine

53403500 - Injector Max Machine 53403500 - Injector Max Machine Operating Instructions Contents Page Introduction Operating Instructions Fuel Injection Cleaner - Petrol Operating Instructions Fuel Injection Cleaner - Diesel 3 Operating

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Simplify with SimplyGo. Now one POC meets the portable oxygen needs of nearly all of your patients

Simplify with SimplyGo. Now one POC meets the portable oxygen needs of nearly all of your patients Simplify with SimplyGo Now one POC meets the portable oxygen needs of nearly all of your patients Treating your oxygen patients has never been easier SimplyGo is the only portable oxygen concentrator (POC)

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual. B bestflangespreader

EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual. B bestflangespreader EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual B bestflangespreader com INDEX THE EQUALIZER RANGE OF MECHANICAL & HYDRAULIC SPREADING

More information

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment Thermo Scientific Capitol Vial Drugs of Abuse Products The tools to create and maintain a safe and drug free environment Drugs of Abuse Specimen Collection We are a world leading manufacturer of Drugs

More information

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.

More information

Impact Uni-Vent 754 Portable Ventilator

Impact Uni-Vent 754 Portable Ventilator Impact Uni-Vent 754 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 754 Portable Ventilator is a portable electronically controlled,

More information

BiPAP Auto Bi-Flex USER MANUAL

BiPAP Auto Bi-Flex USER MANUAL BiPAP Auto Bi-Flex USER MANUAL 2010 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Important... 2 Warnings... 2 Cautions... 3 Contraindications... 3 Symbol

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

WASTE OIL DRAINERS 99. Waste oil drainers

WASTE OIL DRAINERS 99. Waste oil drainers WASTE OIL DRAINERS 99 8 100 WASTE OIL DRAINERS wheel-mounted for drums 20/220 kg Art. 42050 (20/60 kg) Art. 42000 (180/220 kg) Art. 42050 Waste oil drainer for tanks or drums composed of: art. 80050 Trolley

More information

U S E R M A N U A L. (CGA 870 Connection)

U S E R M A N U A L. (CGA 870 Connection) U S E R M A N U A L 1900 Series (CGA 870 Connection) SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090

More information

Armaturenwerk Hötensleben GmbH. AWH-Connect

Armaturenwerk Hötensleben GmbH. AWH-Connect Armaturenwerk Hötensleben GmbH The aseptic connection for vessels "A must for clean vessels " is the aseptic and hygienic connection for your vessels. It was developed for the strict requirements of the

More information

"EC" Series Electric Humidifier

EC Series Electric Humidifier EC-1 Standard Water "EC" Series Electric The Electric from PURE Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain. The humidifier does the rest. These

More information

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent 8762/3/4A,B,C Coaxial Switches Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

M Series with C-Flex

M Series with C-Flex M Series with C-Flex IMPORTANT! Fill in the information below when you receive the REMstar Auto M Series system. Serial No.: (located on the bottom of the device) System Prescribed for: Date of Purchase

More information

Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse well and allow to air dry out of direct sunlight.

Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse well and allow to air dry out of direct sunlight. ResMed CPAP Mask FAQ When and how should I clean my mask? Daily Wash the mask system with warm, soapy water. Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse

More information

B150 Series Commercial Brewer. Direct Plumb Kit

B150 Series Commercial Brewer. Direct Plumb Kit B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

DATA SHEET. Capnography option. www.airliquidemedicalsystems.com. November 2013 V2.2

DATA SHEET. Capnography option. www.airliquidemedicalsystems.com. November 2013 V2.2 November 2013 V2.2 DATA SHEET www.airliquidemedicalsystems.com [1] Monnal T75 (CO 2 )/ Air Liquide Medical Systems APPLICATION AREA OPERATING CONDITIONS Application: Patient categories: Weight: Intensive

More information