Project Summary AH1 WebREPS, LLC
|
|
- Lee Malone
- 7 years ago
- Views:
Transcription
1 Job: Job Information Project Summary Date: Nov 07, 2013 AH1 By: Josh Putman Plan: Job Information 1892 Commerce Avenue, Vero Beach, FL Phone: Fax: Web: License: CAC Project Information For: Notes: Sample 110 Sample Street, Fredericksburg, TX Job Information Design Information Weather: San Antonio Intl AP, TX, US Winter Design Conditions Summer Design Conditions Outside db 32 F Outside db 97 F Inside db 70 F Inside db 75 F Design TD 38 F Design TD 22 F Daily range M Relative humidity 50 % Moisture difference 25 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh Structure Btuh Ducts 3507 Btuh Ducts 2393 Btuh Central vent (0 cfm) Central vent (0 cfm) Humidification Blower Piping Equipment load Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 7066 Btuh Ducts 545 Btuh Heating Cooling Central vent (0 cfm) Area (ft²) Equipment latent load 7611 Btuh Volume (ft³) Air changes/hour Equipment total load Btuh Equiv. AVF (cfm) Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade XP25 SERIES Trade XP25 SERIES Model XP ** Cond XP ** AHRI ref Coil CBX40UHV-036*++TDR AHRI ref Efficiency 10 HSPF Efficiency 13.5 EER, 21.5 SEER Heating input Sensible cooling 2408 Heating output 47 F Latent cooling 1032 Temperature rise 26 F Total cooling 3440 Actual air flow 1147 cfm Actual air flow 1147 cfm Air flow factor cfm/btuh Air flow factor cfm/btuh Static pressure 0.54 in H2O Static pressure 0.54 in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Page 1
2 Job: Job Information Project Summary Date: Nov 07, 2013 AH2 By: Josh Putman Plan: Job Information 1892 Commerce Avenue, Vero Beach, FL Phone: Fax: Web: License: CAC Project Information For: Notes: Sample 110 Sample Street, Fredericksburg, TX Job Information Design Information Weather: San Antonio Intl AP, TX, US Winter Design Conditions Summer Design Conditions Outside db 32 F Outside db 97 F Inside db 70 F Inside db 75 F Design TD 38 F Design TD 22 F Daily range M Relative humidity 50 % Moisture difference 25 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh Structure Btuh Ducts 2955 Btuh Ducts 2017 Btuh Central vent (0 cfm) Central vent (0 cfm) Humidification Blower Piping Equipment load Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 700 Ducts 453 Btuh Heating Cooling Central vent (0 cfm) Area (ft²) Equipment latent load 7453 Btuh Volume (ft³) Air changes/hour Equipment total load Btuh Equiv. AVF (cfm) Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade XP25 SERIES Trade XP25 SERIES Model XP ** Cond XP ** AHRI ref Coil CBX40UHV-036* AHRI ref Efficiency 10 HSPF Efficiency 13.5 EER, 21.5 SEER Heating input Sensible cooling 2408 Heating output 47 F Latent cooling 1032 Temperature rise 26 F Total cooling 3440 Actual air flow 1147 cfm Actual air flow 1147 cfm Air flow factor cfm/btuh Air flow factor cfm/btuh Static pressure 0.54 in H2O Static pressure 0.54 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Page 2
3 VD VD N Sheet 1 Office Server Rm Exercise Master Bed 144 cfm Dining Rm Kitchen 68 cfm 7 " 7 " 144 cfm 12 " 189 cfm 10 " 1 Pantry 12 x cfm 12 x cfm Great Room His 10 " 10 " 12 x cfm 50 cfm 7 " 12 " 12 " 31 cfm 118 cfm 156 cfm 1 20 x cfm 7 " Hall cfm stairs 1 clst2 MBth 100 cfm 2 cfm 32 cfm 1 1 Hers WC Stair Hall vnty 2 Bed 2 50 cfm 49 cfm Foyer 59 cfm 42 cfm Pwdr Bth2 VD VD VD Hall2 10 " WH 1 Laundry 101 cfm 1 20 x cfm Strge 117 cfm Mud Rm 124 cfm Sewing Job #: Job Information Performed by Josh Putman for: Sample 110 Sample Street Fredericksburg, TX Commerce Avenue Vero Beach, FL Phone: Fax: sales@webrepshvac.com Scale: 1 : 182 Page 1 Right-Suite Universal RSU Nov-12 13:03:27...rra Homes\McCaslin Residence.rup
4 N 2nd Floor Bed cfm clst 4 23 cfm Van 4 33 cfm upstairs Hall 3 J J Bth DS 12 x cfm Van 3 Bed3 98 cfm 23 cfm clst 3 Job #: Job Information Performed by Josh Putman for: Sample 110 Sample Street Fredericksburg, TX Commerce Avenue Vero Beach, FL Phone: Fax: sales@webrepshvac.com Scale: 1 : 182 Page 2 Right-Suite Universal RSU Nov-12 13:03:27...rra Homes\McCaslin Residence.rup
5 Job: Job Information Duct System Summary Date: Nov 07, 2013 AH1 By: Josh Putman Plan: Job Information 1892 Commerce Avenue, Vero Beach, FL Phone: Fax: Web: License: CAC Calculation method: EqualFric Supply FR ( in/100ft ): Return FR ( in/100ft ): Equipment pressure losses ( in H2O ): Duct system losses ( in H2O ): Total fan pressure ( in H2O ): Fan air flow ( cfm ): Heating Supply Branch Summary Cooling Htg Clg Design Veloc Shape Duct Duct Cumm. Bed c Round 6 VinlFlx Bed c Round 6 VinlFlx Bed c Round 6 VinlFlx Bth h Round 4 VinlFlx Exercise c Round 6 VinlFlx Foyer h Round 4 VinlFlx Hers h Round 4 VinlFlx His h Round 4 VinlFlx J & J Bth h Round 4 VinlFlx MBth h Round 7 ShtMetl Master Bed c Round 8 VinlFlx Office c Round 7 VinlFlx Pwdr h Round 4 VinlFlx Server Rm c Round 4 VinlFlx WC h Round 4 VinlFlx clst h Round 4 VinlFlx clst h Round 4 VinlFlx clst c 2 20 Round 4 VinlFlx Page 1
6 Supply Trunk Summary Htg Clg Design Veloc Shape Duct Duct Pres st h Round 4 ShtMetl st h Round 8 ShtMetl st c Round 6 ShtMetl st h Round 4 ShtMetl st c Round 6 ShtMetl st c Round 8 ShtMetl st c Round 9 ShtMetl st c Round 8 ShtMetl st c Round 9 ShtMetl st h Round 4 ShtMetl st h Round 4 ShtMetl st h Round 9 ShtMetl st h Round 9 ShtMetl st h Round 6 ShtMetl st c Round 8 ShtMetl st h Round 9 ShtMetl st h Round 9 ShtMetl st h Round 12 ShtMetl st h Round 12 ShtMetl st c Round 16 ShtMetl st c Round 10 ShtMetl st c Round 10 ShtMetl st c Round 4 ShtMetl Return Branch Summary Htg Clg Design Veloc Shape Duct Duct Cumm. rb c Round 9 ShtMetl rb h Round 14 VinlFlx Return Trunk Summary Htg Clg Design Veloc Shape Duct Duct Pres rt c Round 16 ShtMetl rt h Round 14 ShtMetl Page 2
7 Job: Job Information Duct System Summary Date: Nov 07, 2013 AH2 By: Josh Putman Plan: Job Information 1892 Commerce Avenue, Vero Beach, FL Phone: Fax: Web: License: CAC Calculation method: EqualFric Supply FR ( in/100ft ): Return FR ( in/100ft ): Equipment pressure losses ( in H2O ): Duct system losses ( in H2O ): Total fan pressure ( in H2O ): Fan air flow ( cfm ): Heating Supply Branch Summary Cooling Htg Clg Design Veloc Shape Duct Duct Cumm. Dining Rm h Round 7 VinlFlx Dining Rm-A h Round 7 VinlFlx Great Room h Round 8 VinlFlx Great Room-A h Round 8 VinlFlx Kitchen c Round 8 VinlFlx Laundry c Round 6 VinlFlx Mud Rm h Round 6 VinlFlx Pantry h Round 4 VinlFlx Sewing h Round 6 VinlFlx Supply Trunk Summary Htg Clg Design Veloc Shape Duct Duct Pres st h Round 9 ShtMetl st h Round 12 ShtMetl st c Round 10 ShtMetl st c Round 10 ShtMetl st c Round 9 ShtMetl st c Round 9 ShtMetl st h Round 9 ShtMetl st h Round 6 ShtMetl st c Round 16 ShtMetl st h Round 14 ShtMetl Page 3
8 Return Branch Summary Htg Clg Design Veloc Shape Duct Duct Cumm. rb c Round 16 ShtMetl Page 4
Below are detailed instructions for using the EMS load calculator.
Introduction The EMS load calculator is designed to make load calculating as painless as possible. For sizing the equipment, only the first three tabs (Steps 1, 2 & 3) need to be completed. This process
More informationHVAC System Installation & Best Practices in New Construction. Anthony Stamatopoulos ACI New Jersey - 2007
HVAC System Installation & Best Practices in New Construction Anthony Stamatopoulos ACI New Jersey - 2007 This Session Outline: 1. HVAC system Design, Selection and Installation Learn to list the steps
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationUNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM
Page 1 UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM Each of the 38 points of requested information is discussed, and references to the supporting manual are given to substantiate the requirement.
More informationMakeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects
Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony
More informationWhole House Dehumidification for Occupant Comfort and Energy Savings
Downloaded from www.rsrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs. Whole House Dehumidification for Occupant Comfort Energy Savings June 2009
More informationWORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
More informationAir Conditioning Contractors of America
Air Conditioning Contractors of America WHO IS ACCA???? Industry Manuals Residential D, J, S, H, RS, T, P A manual J load calculation is a measurement of how much heating and cooling capacity a home will
More informationQUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM
QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM TOGETHERWESAVE.COM IS IT TIME TO REPLACE YOUR HVAC SYSTEM? If your heating and cooling system is 15 to 20 years old and is experiencing problems,
More informationBuilding Performance Solutions HVAC Design Guide, 2007
Building Performance Solutions HVAC Design Guide, 2007 HVAC sizing, system design, layout, and installation shall be sized according to (Air Conditioning Contractor of America), ACCA manual J8, 8 th edition,
More informationStrategy Guideline: HVAC Equipment Sizing
Strategy Guideline: HVAC Equipment Sizing Arlan Burdick IBACOS, Inc. February 2012 This report received minimal editorial review at NREL NOTICE This report was prepared as an account of work sponsored
More informationAC System Equipment Specification, Installation and Operational Options for Improved Indoor Humidity Control
AC System Equipment Specification, Installation and Operational Options for Improved Indoor Humidity Control Authors Don B. Shirey, III Original Publication Shirey III, D., "AC System Equipment Specification,
More informationFLORIDA SOLAR ENERGY CENTER
FLORIDA SOLAR ENERGY CENTER Creating Energy Independence Since 1975 Impact of Energy-Efficiency Parameters on Home Humidity Rob Vieira Florida Solar Energy Center A Research Institute of the University
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationLaboratory Performance Testing of Residential Window Mounted Air Conditioners
Laboratory Performance Testing of Residential Window Mounted Air Conditioners Jon Winkler Chuck Booten Dane Christensen Jeff Tomerlin April 29, 2012 NREL is a national laboratory of the U.S. Department
More informationHVAC Simplified Approach Option
HVAC Simplified Approach Option Part I Project Address: City: HVAC System Designer of Record: Date: Zip: Qualification The building is 2 stories or less in height and has a gross floor area is less than
More informationHVAC Basic Science - System Capacity
HVAC Basic Science - System Capacity Btu/hour, btu/h, b/h, btuh. btu?? 1 MBH = 1000 btu/hour 1 KBH = 1000 btu/hour 1 ton of cooling= 12,000 btu/hour 1 watt = 3.414 btu/hour 1 kilowatt = 1000 watts = 3,414
More informationHidden Power Drains: Residential Heating and Cooling Fan Power Demand
Hidden Power Drains: Residential Heating and Cooling Fan Power Demand ABSTRACT John Proctor, Proctor Engineering Group, Ltd. Danny Parker, Florida Solar Energy Center This paper compiles power draw, airflow,
More informationLower Energy Costs with Rooftop Air-Conditioning Package Units
Lower Energy Costs with Rooftop Air-Conditioning Package Units Sponsored by Mike West, PhD, PE Advantek Consulting, Inc Package Unit Efficiency Factors Sensible and latent performance ratings Unit efficiency
More informationEFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE
P (5, EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE Ronald H. Howell, Professor Luis Rosario, Graduate Student Antonio Bula, Graduate Student Department of Mechanical Engineering
More informationZoned Air Conditioners - A Real Value?
H114 Prepared by: Proctor Engineering Group, Ltd. San Rafael, CA 94901 (415)451-2480 Zoning Ducted Air Conditioners, Heat Pumps, and Furnaces: Summary of a Case Study prepared for the California Statewide
More informationWhy Do I Need Precision Air Conditioning?
Why Do I Need Precision Air Conditioning? Executive Summary Today's technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationComfort Conditioning & Indoor Air Quality
This article was published in ASHRAE Journal, May 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Reprinted here by permission from ASHRAE at www.newellinstruments.com.
More informationINTEGRATED HEAT PUMPS FOR COMBINED SPACE CONDITIONING AND WATER HEATING
INTEGRATED HEAT PUMPS FOR COMBINED SPACE CONDITIONING AND WATER HEATING J. J. Tomlinson, Group Leader, Oak Ridge National Laboratory Oak Ridge, Tennessee USA C. K. Rice, Ph. D., Research Staff, Oak Ridge
More informationResidential HVAC System Sizing
Residential HVAC System Sizing William P. Goss University of Massachusetts, Amherst, Massachusetts, USA Corresponding email: goss@acad.umass.edu SUMMARY Heating, ventilating and air-conditioning (HVAC)
More informationEnergy Efficient Homes: Air Conditioning
Energy Efficient Homes: Air Conditioning Quick Facts The average energy bill for a typical single family home in the U.S. is $2,200. Roughly 46 percent of the bill, or $1,012, is spent on heating, ventilation,
More informationAPPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application
APPLICATION GUIDE Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application Section Comparison of Latent Cooling Performance of Introduction Most commercial HVAC systems
More informationHow To Get An Energy Star For A Small Duct High Velocity (Sdhv)
May 12, 2014 Ms. Abigail Daken U.S. Department of Environmental Protection (EPA) ENERGY STAR Program 7401 Alabama Avenue St. Louis, MO 63111 314-481-9000 www.unicosystem.com Delivered via email to: CAC-ASHP@energystar.gov
More informationEnergy Efficient Homes: Air Conditioning 1
FCS3262 Energy Efficient Homes: Air Conditioning 1 Wendell A. Porter, Hyun-Jeong Lee, and Kathleen C. Ruppert 2 Quick Facts Heating, ventilation and air conditioning accounts for more than 40% of your
More informationComparing Fuel Costs of Heating and Cooling Systems
Comparing Fuel Costs of Heating and Cooling Systems June 2003 Introduction One of the most common questions posed to energy specialists at Engineering Extension asks for a comparison between costs to operate
More informationAir-Conditioning Buying Guide
Air-Conditioning Buying Guide Buying a new air-conditioning system is a big decision. This Air-Conditioning Buying Guide can help you make the right choice, save energy and money. Shop with confidence
More informationHVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.
HVAC FORMULAS TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F 288,000 BTU/24 hr. 12,000 BTU/hr. APPROXIMATELY 2 inches in Hg. (mercury) = 1 psi WORK = Force
More informationDr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida
Optimizing 100% Outside Air Systems with Heat Pipes Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida Introduction To meet increasingly rigorous building codes
More informationMassachusetts COOL SMART. RESIDENTIAL CENTRAL AC/DUCTED AIR SOURCE HEAT PUMP Rebate Application
Massachusetts COOL SMART 2015 RESIDENTIAL CENTRAL AC/DUCTED AIR SOURCE HEAT PUMP Rebate Application COOL SMART CENTRAL AC/HP PROGRAM COOL SMART is a residential central air conditioning rebate program
More informationHVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
More informationHigh Altitude HVAC. Silvertip Integrated Engineering Consultants mhaughey@earthlink.net www.silvertipconsultants.com
Presentation to: Rocky Mountain ASHRAE 2013 Tech Conference April 19, 2013 High Altitude HVAC Design Considerations by: Michael D. Haughey, PE, HBDP, CEM, LEED TM AP 2013 Silvertip Integrated Engineering
More informationTom Brooke, PE, MBA, CEM tabrooke@embarqmail.com
Tom Brooke, PE, MBA, CEM tabrooke@embarqmail.com Framework, perspective or example in a particular discipline at a given time These four new models are: New and additional, or Updated Today's Paradigm
More informationHeating, Ventilation & Air Conditioning Equipment
FinAnswer Express Utah Incentive Catalog Effective as of May 19, 2012 Heating, Ventilation & Air Conditioning Equipment Rocky Mountain Power provides incentives for many types of energy-efficient technologies.
More informationComparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
More informationMassachusetts COOL SMART
Massachusetts COOL SMART 2015 RESIDENTIAL DUCTLESS MINI-SPLIT HEAT PUMP Brochure & Rebate Application Revised 4/2015 Ductless Mini-Split Heat Pump REBATE National Grid is offering residential electric
More informationEnergy Efficiency. Energy Efficient Home Cooling:
Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling
More informationElement D Services Heating, Ventilating, and Air Conditioning
Load Calculation Criteria PART 1 - GENERAL 1.01 OVERVIEW A. This section includes requirements for calculating HVAC cooling and heating loads. B. Load calculations must be performed in accordance with
More informationKitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air
The Pennsylvania Housing Research Center Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air Builder Brief: April 2012 Anthony C. Jellen, PE & Brian M. Wolfgang, EIT, Michael A. Turns, MS
More informationEPA WaterSense for New Homes Program DOE Zero Energy Ready Home Quality Management Guidelines
22 Harbor Ave Dunhill Companies LTD John S. Rodenhizer 10/28/2014 EPA WaterSense for New Homes Program DOE Zero Energy Ready Home Quality Management Guidelines -7 REM/Rate - Residential Energy Analysis
More informationSINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
More informationThe XP17 provides comfort without comparison.
ideal The XP17 provides comfort without comparison. Catching those quick moments to relax with your favorite person is a cherished privilege that shouldn t be affected by the air around you. The XP17 from
More informationCALCS-PLUS. 2010 Florida Building Code Energy Conservation Glitch Supplement
2010 Florida Building Code Energy Conservation Glitch Supplement Today's Discussion Overview of Recent Changes Prescriptive or Performance Compliance Methods? Mandatory Provisions Reading the Forms Overview
More informationAir Conditioner Problems - How to Keep it Running Smoothly
SMART AND COOL THE ART OF AIR CONDITIONING Common misconceptions can contribute to a home environment that is too cold, too hot, or too humid. BY JOHN PROCTOR If you re confused about how to get an air
More informationA Glossary of HVAC Terms:
Since 1979 TACL A537C Doctor COOL & P rofessor HEA T The Team For All Seasons TM A Glossary of HVAC Terms: Confused by the many terms and acronyms surrounding your indoor comfort system? Don t be! This
More informationVenice Library Humidity Study. for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205. Report April 13, 2015
for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205 Report April 13, 2015 Moses & Associates, Inc. 2209 NW 40 th Terrace, Suite A Gainesville, FL 32605 FL License EB-0003097
More informationEnergy & Equipment Sizing Analysis
Energy & Equipment Sizing Analysis 1860 Ridge Creek Lane, Bulverde, TX 78163 - Office: (210) I Foam IT - Fax: (830) 885-2804 - Website: www.foamitnow.com Cost Analysis - 30 Year Fixed Rate Mortgage Side-by-Side
More informationHeating, Ventilation & Air Conditioning Equipment
FinAnswer Express Wyoming Incentive Catalog Effective as of October 1, 2011 Heating, Ventilation & Air Conditioning Equipment Rocky Mountain Power provides incentives for many types of energy efficient
More informationHVAC Efficiency Definitions
HVAC Efficiency Definitions Term page EER - 2 SEER - 3 COP - 4 HSPF - 5 IPLV - 6 John Mix May 2006 Carrier Corporation 1 Energy Efficiency Ratio (EER) The energy efficiency ratio is used to evaluate the
More informationResidential Air Conditioning. Program Standards
Residential Air Conditioning Program Standards Effective: January 1, 2015 Florida Power & Light Company Residential Air Conditioning Program Standards Table of Contents Program Objective... 1 Customer
More informationair conditioners how to choose a cooling system
air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced
More informationHome Energy Evaluation Report
Home Energy Evaluation Report Nate Begeman, 1550 Saint Francis Dr San Jose, CA 95125 Air Infiltration Current Air Leakage 2,852 Current Air Changes Per Hour 0.91 Recommended Air Changes Per Hour 0.35 Percent
More informationCreating Efficient HVAC Systems
Creating Efficient HVAC Systems Heating and Cooling Fundamentals for Commercial Buildings Heating, ventilating, and air conditioning (HVAC) systems account for nearly half of the energy used in a typical
More informationPACKAGE COOLING, PACKAGE HEAT PUMP & PACKAGE GAS UNITS
PACKAGE COOLING, PACKAGE HEAT PUMP & PACKAGE GAS UNITS SERVICE INSTRUCTIONS AMANA REFRIGERATION, INC., AMANA, IOWA 52204 MANUFACTURING NUMBERS COVERED IN THIS MANUAL SEE MODEL AND MANUFACTURING NUMBERS
More informationIntroduction. Motor Types
QwikSEER+ Theory of Operation and Retrofit Potential Mainstream Engineering Corporation Rockledge, FL 32955 http://www.qwik.com/products/qwikseer/index.jsp Prepared by Robert P. Scaringe and R. Paul Roth
More informationDefining Quality. Building Comfort. Precision. Air Conditioning
Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
More informationHow and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners
How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners White Paper #56 Revision 2 Executive Summary Today's technology rooms require precise, stable environments in order for
More informationAPPLICATION GUIDE. Moisture Management in Waterborne Climate Systems
APPLICATION GUIDE Moisture Management in Waterborne Climate Systems Contents Introduction 3 WBCS Concept 3 Condensation 4 Moisture Sources in the Space 4 Impact of a High Moisture Load 5 Designing to Manage
More informationGet the FACTS about SEER and Deliver Better Customer Value
What is SEER? SEER stands for Seasonal Energy Efficiency Ratio. It s a number that describes how well air-conditioning equipment works. A higher SEER means better efficiency and lower energy bills. SEER
More informationTotal Heat Versus Sensible Heat Evaporator Selection Methods & Application
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration
More informationBy Tom Brooke PE, CEM
Air conditioning applications can be broadly categorized as either standard or critical. The former, often called comfort cooling, traditionally just controlled to maintain a zone setpoint dry bulb temperature
More informationHeating & Cooling Efficiency
Heating & Cooling Efficiency Advantages of Geothermal HVAC Efficiency Keith Swilley Gulf Power Company Why Gulf Power Promotes Energy Efficiency? Customer Satisfaction Education Help Customers Make Smart
More informationDuct Design. Presented by Dave Janquart
Duct Design Presented by Dave Janquart Overview of Topics Duct design Duct insulation SMACNA Standards Factors Influencing Duct Design Equipment Losses Air Velocity Duct Material Duct Size & Shape Length
More informationFAN COIL UNIT SOFTWARE User Manual
User Manual Thanks for using Tiba fan coil units' selection software. To start the selection process to software selection there are some steps we need to follow: Front page: 1. Only selection 2. Performance
More informationBPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda
BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Photo of scott at AC with guages 1 Agenda Day I Refrigerants Introductions Verifying Charge Super Heat Paperwork & Sign-In Subcooling
More informationPerformance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
More information1/9/2015. Create Energy Saving Comfort & Cut Costs with Affordable HVAC Zone Controls. Educate Builders on the Importance of ZONING.
Create Energy Saving Comfort & Cut Costs with Affordable HVAC Zone Controls JANUARY 22, 2015 10 11 AM Richard Foster - Presenter(s): ZONEFIRST, Elmwood Park, NJ Educate Builders on the Importance of ZONING
More informationDUCT SYSTEM DESIGN CONSIDERATIONS Part 1
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 DUCT SYSTEM DESIGN CONSIDERATIONS Part 1 by Roger M Hensley, CMS TYPES OF SUPPLY DUCT SYSTEMS There are several basic
More informationSTANDARD COMMISSIONING PROCEDURE FOR PACKAGED HEAT PUMP (AIR-TO-AIR) & AIR CONDITIONING UNITS
STANDARD COMMISSIONING PROCEDURE FOR PACKAGED HEAT PUMP (AIR-TO-AIR) & AIR CONDITIONING UNITS BUILDING NAME: APPLICATION #: BUILDING ADDRESS: NAME & FIRM OF PERSON(S) DOING TEST: DATE(S) OF TEST: General
More informationFor Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System
For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone
More informationHVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming
More information85 F 80 F 50% 75 F 70 F 73.0/61.8 45 F 10% Figure 1
Feb. 07 INTRODUCTION: Wrap around heat pipes are air-to-air heat exchangers that are installed in the airstream upstream and downstream of a cooling coil to deliberately reduce the Sensible Heat Ratio
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationLIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.
LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air Trevor Wende Vice President, Marketing Advantix Systems, Inc. 0 Humidity: The Hidden Cost Driver Conventional A/C process Start
More informationENHANCED LABORATORY HVAC SYSTEM
ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of
More informationCharacteristics of Evaporators
Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of
More informationEnergyPro Building Energy Analysis. Assisted Living Building
EnergyPro Building Energy Analysis Assisted Living Building EnergyPro Building Energy Analysis for an assisted living building Project Scope The purpose of the EnergyPro energy model was to evaluate the
More informationMoisture Control. It s The Dew Point. Stupid! Its not the humidity.
Moisture Control Its not the humidity. It s The Dew Point Stupid! Mike Schell EpiphanyTec Inc. Santa Barbara, CA mschell@epiphanytec.com 805 687-3175 Matching great technology to market need! Topics SHR
More informationResidential electric heating and cooling rebates
Rhode Island Residential electric heating and cooling rebates Save energy and money, improve comfort, and make your home better with these energy savings offers for residential electric customers. n Systems
More informationTECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
More informationHow To Make A High Efficiency Thermostat
Zoning with Variable Speed Mini-Split Systems Fujitsu Service Training Welcome - Thank you for attending Did you know? In 1940 only 42% of homes in the US had central heating In 1970 20% of homes had central
More informationFTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
More informationGuidelines for Complying with BPI s Technical Standards for the Air Conditioning and Heat Pump Professional
Guidelines for Complying with BPI s Technical Standards for the Air Conditioning and Heat Pump Professional Version NV.1.02 Adapted for Clark County, NV September 23, 2010 Prepared for: Building America
More informationHRV and ERV Best Practices. December 18, 2012 Portland Metro Home Builders Association
HRV and ERV Best Practices December 18, 2012 Portland Metro Home Builders Association The Basics: The X Flow Ports Connected to Inside 72 F 61 F 42 F 32 F Ports Connected to Outside The Single Most Important
More informationProduct Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL
Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally
More informationwattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI) rockymountainpower.net/newhomes 1-855-269-8386
Contractor-Certified HVAC Quality Assurance (HVAC-QI) HVAC Quality Assurance (HVAC-QI) Checklists The following checklists are required, with all applicable items completed and checked, including final
More informationExhaust Calculation Booklet
Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.com ADC Part No. 450450 Exhaust
More informationIntegrating Kitchen Exhaust Systems with Building HVAC
Design Guide 3 Improving Commercial Kitchen Ventilation System Performance Integrating Kitchen Exhaust Systems with Building HVAC This design guide provides information that may help achieve optimum performance
More information1932 Lexington Houston, Texas 77098-4220 (713) 524-4877. Recommendations for installation of cooling systems
1932 Lexington Houston, Texas 77098-4220 (713) 524-4877 The purpose for this information is to provide a better understanding of the HVAC equipment, components, designs, and installations, of HVAC system
More informationDEEMED SAVINGS TECHNICAL ASSUMPTIONS
Product: - Direct-Evaporative Pre-cooling for Air-Cooled Condensers (DEPACC) Prescriptive rebates will be offered for Direct Evaporative Pre-cooling Technology for Air Cooled Condensers (DEPACC) for Rooftop
More informationDUCT DESIGN FOR THE TIME CONSTRAINED WORLD
DUCT DESIGN FOR THE TIME CONSTRAINED WORLD This is a simplified duct design process. It assumes the user has covered the following requirements before starting: 1: Identify room by room heat loss and heat
More informationResidential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer
Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code
More informationHospital Application Guide. Cost-effective climate control for hospitals
Hospital Application Guide Cost-effective climate control for hospitals Munters is the world leader in dehumidification Munters is the largest manufacturer of dehumidifiers in the world. Since developing
More informationPNEUMATIC CONTROLS Dual Duct Sequence Descriptions
PNEUMATIC CONTROLS Dual Duct Sequence Descriptions Model ADCC dual duct throttling unit control sequences fall into three basic categories: mixing, without mixing, and constant volume. The piping diagrams
More informationECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
More information