Technical data of the sauna stove Sauna stove type Stoveman 20 Model
|
|
- Beatrix Heath
- 7 years ago
- Views:
Transcription
1 APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE Technical data of the sauna stove Sauna stove type Stoveman 20 Model Stoveman 20R;20R-M Nominal heat capacity, i.e. ability to 20 kw heat the room Fuel Wood logs with length up to 40 cm Fuel quantities to be added 15 kg in three parts Minimum necessary draught 12 Pa Carbon dioxide emissions with 13% O 2 0,65% content Overall efficiency 65% Flue gas temperature 461 C Weight of sauna stove without stones 75kg Weight of sauna stove s stones 160kg Minimum cross-section of ventilation 7850 mm² openings Hot room size 12m³-20m³ Minimum cross-section of smoke flue 10200mm² CE mark
2 INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE The STOVEMAN sauna stove is intended for providing dry or humid heat in a sauna. Our product range includes various modifications of the Stoveman sauna stoves. The selection has round and angular-shaped stoves. The stove can have a hot water boiler, a glass door and a wall penetration for fire chamber. An appendix to this manual includes a copy of the type approval for CE marking of the sauna stove and the data of the sauna stove model. Commissioning Read this manual carefully before commissioning the sauna stove! The first heating must be performed outside or in a well-ventilated hot room, because the final curing of the external heat-resistant paint of the sauna stoves is completed only after heating and the curing process may give off an unpleasant burning smell. Avoid scratching the sauna stove before that. It s not recommended to fill the sauna stove with stones before the first heating. The stones of the sauna stove must be large granite fieldstones or also sauna stove stones sold in specialised stores. Installation Installation of the sauna stove must follow all local standards and regulations, including those related to national and European Union standards applicable to installation, incl. EN 15821:2010. The sauna stove must be installed onto a base made of non-flammable material and having sufficient load-bearing capacity. The installation of the sauna stove must follow all safety requirements and required distances from other materials as stated on the CE marking. The CE marking is attached to the sauna stove at the lower edge of the mesh, at the right side when looking at the fire chamber s door. If the stove is installed into a recess made of non-flammable material (stone, concrete), then the distance between the wall and the stove must be at least 100 mm, to allow for proper air movement. Due to major temperature fluctuations, the sauna stove stones may crumble over time and lose their necessary properties. Due to this it is recommended to empty the sauna stove from old stones once a year and to replace them with fresh stones. Safety requirements (General fire safety requirements) General fire safety requirements valid in the country must be respected. Minimum required safe distances to flammable materials: At sides and behind the stove 500 mm In front of the stove 1,000 mm From top of the stove to the ceiling 1,200 mm If heat insulation is used, then the required safety distances may be reduced to half; with double heat insulation, the safety distances may be reduced to a quarter. If any wooden walls (panels, boards, timbers) are closer to the stove than the minimum required safety distance, then those wall surfaces must be protected with thermal insulation (for example with a Termoluja board). In that case, the minimum required distance between the thermal insulation and the sauna stove is 250 mm. 1
3 If the sauna stove is installed onto a floor made of wood or other flammable material, then a concrete base must be cast, with the thickness of at least 60 mm and with dimensions exceeding those of the stove by 300 mm on sides and 400 mm in front. The wall penetration for fire chamber of the sauna stove must be made through inflammable wall (stone, concrete, etc.). It is also recommended to use additional thermal insulation made of mineral wool, etc. (see the figure). There must be no electrical equipment or cables within the safety zone of the sauna stove. NB! A mechanical ventilation system operating by air extraction may cause air exchange problems in the room and insufficiency of combustion air for the fire chamber; thus, such a ventilation system may only be designed and built under responsibility of a specialist with the relevant license. Connecting the sauna stove to the smoke flue As a rule, the Stoveman sauna stoves have the flue gas outlet opening on top of the sauna stove. Special metal flue pipes must be used for connecting the sauna stove to the smoke flue; the flue pipe connections must be sealed with heat-resistant sealing cord if necessary. Any bends in the connection pipes must be round and wide, in order to ensure minimum obstructions of the chimney draught. The flue pipe must enter through the chimney wall and it must be sealed with mineral wool. The connection of the sauna stove to the smoke flue must be made by a specialist of the relevant field. The sauna stove must not be connected to a shared smoke flue. The sauna stove must not be modified without the manufacturer s consent. Heating the sauna stove NB! The sauna stove must be fired with wood logs only. Avoid overheating the sauna stove; this would be indicated by the sauna stove s shell starting to glow red. Overheating deforms the metal and the manufacturer will not bear any liability for defects of the stove resulting from that. The initial heating of a new sauna stove is recommended to do with half the stove-load of firewood and without the stones; the room must be ventilated afterwards. During the initial heating, the final curing of the heat-resistant paint takes place and it may be accompanied by an unpleasant smell in the room. To stop the burning process of an overheated sauna stove, the ash drawer must be closed completely and the fire chamber s door must also be kept closed; if possible, air influx to the room must be shut off as well. It is recommended to pick the first stove-load of firewood (the ignition load) from smaller and easily-igniting pieces of wood, thus having more air and less weight than the standard stoveload. The flow of combustion air is regulated by changing the position of the ash drawer. For igniting the stove, the recommended position of the ash drawer is open by up to 10 mm. When the wood has started to burn, the ash drawer must be placed so that the distance between the ash drawer s front and the fire chamber s wall is 2 3 mm, depending on the actual draught. It is recommended to have a set of handy stove accessories (shovel, brush, stove iron) in the lower-temperature part of the hot room (up to 40 C) for cleaning the fire chamber and for safe operation of the sauna stove. As a rule, the fire chamber door must be kept close during heating. The door can be opened only for the time of adding firewood. With sauna stoves having a glass door, avoid getting water on the hot glass. The hardened glass of the door is not covered by the product warranty. The time needed for heating up the hot room depends on the heat conductivity of the wall materials, the volume of the room and the heating capacity of the sauna stove. 2
4 The ash drawer of the sauna stove must be cleaned before each heating, because the draught is regulated by way of adjusting the ash drawer s position. If the sauna has not been used for a long time, then the internal flue channels, the fire grid and the ash drawer must be inspected and if necessary then cleaned, and the chimney and the smoke flue must be inspected and if necessary then cleaned by a specialist before starting to heat the sauna stove. The heating surfaces of the fire chamber must be cleaned regularly, i.e. at least after every 20 heatings of the sauna stove. The chimney and the smoke flue must be leaned at least once a year. The cleaning of the sauna stove must follow all local standards and regulations prescribing fire safety requirements for cleaning of heating equipment. It is recommended to keep the grilles of the ventilation openings clean and to clean the ventilation channels at least once per year. The exterior of the sauna stove becomes hot during heating; contact with unprotected skin may cause burns. Always use the delivered safety cloth for grabbing the handle of the fire chamber door when heating the stove. Never throw salt water onto the sauna stove! It is not recommended to throw water with high hardness grade or excessive iron content onto the sauna stove. Product warranty The sauna stoves have a manufacturer s warranty of 24 months after the date of purchase, proven by a purchase slip. The warranty covers defects due to manufacturing errors. The warranty does not cover the following effects caused by the joint effect of temperature and steaming water: Metal deformations; Effects on surface covering; Effects on door glass. Reclamations due to defects must be sent via to the address of kontakt@evt.ee or as paper mail to the address of AS Eesti Vanglatööstus, Kalmistu tee 22, Tallinn 11216, Estonia. The reclamation must describe the defect and must state the serial number of the sauna stove. The serial number is marked on the sauna stove, at the lower edge of the mesh, at the right side when looking at the fire chamber s door, and/or on the top plate of the fire chamber. The reclamation must be accompanied by photographs of the places were the defect is apparent, and by copies of the purchase documents of the sauna stove. Manufactured by: AS Eesti Vanglatööstus Kalmistu tee TALLINN, ESTONIA Tel.: Fax: kontakt@evt.ee 3
5 Fig 1. Heat resistant insulation board Fig 2. 4
6 Fig 3. Fig 4. 5
version 1.0 Made by NARVI Oy Finland Kota Kuru 14 and 20 sauna heaters Installation, user and maintenance instructions
version 1.0 Made by NARVI Oy Finland Kota Kuru 14 and 20 sauna heaters Installation, user and maintenance instructions GB GB 2 GB Content 1.1 Technical data 4 2. Before you install the sauna heater 5 2.1
More informationChimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
More information(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
More informationINSPIRE 40/45/55 INSTRUCTIONS OPERATING APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED FUELS. Inspire 40 Inspire 45
INSPIRE 40/45/55 APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED FUELS OPERATING INSTRUCTIONS Inspire 40 Inspire 45 Inspire 55 www.heta.dk Installation and Operating Instructions
More informationSIBIR MANUAL V110 KE. English page 5 RKE - 1D 822 70 66-02
SIBIR MANUAL RKE - 1D V110 KE English page 5 822 70 66-02 2 1 A. Flue tube E. Adapter I. Thermostat B. Flue baffle F. Burner base J. Lever arm C. Control knob G. Lamp glass D. Fuel gauge H. Lamp glass
More information1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
More information556/586 NEW NEW. One step closer to the fire. www.contura.eu
001 556/586 NEW NEW One step closer to the fire www.contura.eu 378 MILJÖMÄRKT 1 Closer to the fire with large glass side panels NEW! The new Conturas 556/586 feature large glass side panels to enhance
More informationA new range of clean burning multifuel stoves
A new range of clean burning multifuel stoves The New Range of Bohemia X Multifuel Stoves - approved for wood burning use in smoke control areas throughout the UK* Pevex Enterprises has been established
More informationDecree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
More informationModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!
Secure and efficient IT room solutions Composite Panel Systems Compared Panel Systems are not all the same! When it comes to accommodating critical IT systems, the first issue to look at is the environment
More informationFREESTANDING CLEAN AIR WOODBURNER
Please read this booklet and keep for future reference for the safe installation of your: FREESTANDING CLEAN AIR WOODBURNER This fire conforms with Ecan Requirements All installations must be in accordance
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationTECHNICAL DESCRIPTION
FIREPLACES, STOVES AND FIREBOXES TO BUILD IN (WITHOUT FORCED VENTILATION AND WATER HEAT EXCHANGER) TECHNICAL DESCRIPTION The fireplaces of Prity are intended for heating of private houses and public premises
More informationInstallation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:
More informationSRP Pricelist 2015 Including VAT. Stoves for every home
SRP Pricelist 2015 Including VAT Stoves for every home Valid from 01-10-2015 UK Contents Contura Stoves C400 Series... 2-4 C500 Series... 5-9 C600 Series... 10-13 C700 Series... 14-15 C800 Series... 16-17
More informationElectric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL
Electric Kettle Model: SK-1717 INSTRUCTIONS MANUAL Thank you for your purchase. Please read this Instruction Manual thoroughly before use and keep in a safe place for future reference. READ ALL INSTRUCTIONS
More informationINSTALLATION GUIDE FOR GIROLAMI CAMINETTI OVEN
Dear Customer, Congratulation for buying a Girolami Caminetti oven. You have made the right choice in purchasing a product from the world leader producer of wood fired ovens. With a perfect installation,
More informationSan josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
More informationFire-resistant barriers: background on requirements and determination method. Reading guide for test reports.
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports. Report number C 1395-1E-RA-003 d.d. May 14, 2014 Fire-resistant barriers: background on requirements
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More informationNOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.
More informationWood Pellet Stove 101
Wood Pellet Stove 101 By Eric J. Kacvinsky Kinsman Stoves, LLC. And Brookfield Stoves & Supply With assistance from Mark D. Manley Painesville Pellet and Stove, LLC Wood pellets are made mainly of sawdust,
More informationSafe Method: Gas Safety in Catering Establishments
Safe Method: Gas Safety in Catering Establishments Safety Point Why? What do you do? Gas equipment and services must only be installed, maintained and repaired by a Gas Safe registered installer. Check
More informationHIGH QUALITY COMPONENTS
Eco reen Line HIGH QUALITY COMPONENTS that distinguish Eco reen Line series of devices 1. The lambda probe it performs a function of an oxygen sensor (O ) in the exhaust gasses, providing constant diagnostic
More information8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
More informationStove-boiler for solid fuels 12-30 KW Directions for use and assembling
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................
More informationAZB 800. Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884
AZB 800 Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884 Ø120 1310 Ø125 50 125 6 720 610 703-00.1O for Gas Condensing Boilers: OSW Contents Contents Safety instructions 2 Symbols 2 1 Use 3 1.1 General
More informationKey energy-efficient features of your new home
Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from
More informationBergen. NO Monterings- og bruksanvisning 2 GB Installation- and user manual 9 SE Installations- och bruksanvisning 15 FI Kättöohje 21
Bergen NO Monterings- og bruksanvisning 2 GB Installation- and user manual 9 SE Installations- och bruksanvisning 15 FI Kättöohje 21 Product no: SA-BERG0-000 RRF no: 40 10 2244 Last updated: 01.01.2013
More informationUnderwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
More informationPre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E
Electric Cookers Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible manufacturers
More informationBIOHOUSING Seminar Success stories of biomass heating in small scale
BIOHOUSING Seminar Success stories of biomass heating in small scale Pellet stove: attractive and fully automatic central heating systems Lorenzo Corbella 28th October 2008 House of Cities, Municipalities
More informationStructural fire design Eurocode 5-1.2 Timber structures
Background and Applications Brussels, 18-20 February 2008 Dissemination of information workshop 1 Structural fire design Eurocode 5-1.2 Timber structures Jochen Fornather Austrian Standards Institute jochen.fornather@on-norm.at
More informationChimneys in Thatched Properties
Chimneys in Thatched Properties Compliance with Building Regulations when installing or repairing a chimney or re-thatching a roof that abuts a chimney The increasing problem of thatch fires Over the last
More informationMold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
More informationINSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin
INSTRUCTION FOR ASSEMBLY 150x180 v Traditional sauna cabin 1. SAUNA PLAN 1800 LIGHT UNDER THE BENCH VENTILATION OUTLET UPPER BENCH 600 1500 LOWER BENCH 400 700 1656 956 HEATER 366 381 690 815 Light switch
More informationOntario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationRapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
More informationTECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICS The FACI boilers for the production of warm water up to + 95 C they are built with a auto drive structure in a sheet of special steel of strong thickness of high mechanical resistance
More informationDRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
More informationTECHNICAL INSTRUCTIONS FOR CONCEPT 2 AND CONCEPT 2 MINI CENTRAL HEATING COOKERS
TECHNICAL INSTRUCTIONS FOR CONCEPT 2 AND CONCEPT 2 MINI CENTRAL HEATING COOKERS Dear Customers, We would like to thank you for your trust and to congratulate you since by this purchase you have become
More informationPELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
More informationGNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
More information2-SLICE COOL TOUCH TOASTER
2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.
More informationflueless gas fires & stoves
Made in the UK flueless gas fires & stoves Latitude 4500 with satin trim Conventionally flued fires lose most of their heat up the chimney. Burley flueless gas fires are designed to operate without a flue
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationHOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?
WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by
More informationSafety Storage Cabinets
Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased
More informationUDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
More informationGas-Fired, Residential Storage Type Water Heaters
Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors
More informationMAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation
MAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation With Finlandia and Magnum RC Control Centers Use and installation manual
More informationMODELS BR517R & BR517S (G.C. 32-032-11 & 32-032-12) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires
O W N E R G U I D E MODELS BR517R & BR517S (G.C. 32-032-11 & 32-032-12) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires *Covered by GB Patent 2.202.622.B This Owner Guide is
More informationUSER MANUAL and INSTALLATION MANUAL
InisMor USER MANUAL and INSTALLATION MANUAL Inis Mor User manual. Congratulations on the purchase of your Inis Mor back boiler stove. When fitted and operated correctly, you should enjoy many years, trouble
More informationSquash Court Design general points
Squash Court Design general points Contents: Contents:... 1 1. Squash Court Dimensions... 2 2. CourtTech Walls... 3 3. Dimensional requirements for courts with CourtTech Walls... 3 4. Loading of CT System
More informationAccessory Manual Ventilation Section Model Comfort Circle
Accessory Manual Ventilation Section Model Comfort Circle Manual version:. R a Copyright and trademarks All the information and drawings in this manual are the property of Biddle and may not be used (other
More informationOWNER S MANUAL FOR THE PATIO SAUNA
OWNER S MANUAL FOR THE PATIO SAUNA CONGRATULATIONS! You are about to install the world s leading portable sauna. No other sauna manufacturer can offer you the features and owner support that Saunatec,
More informationMAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.
MAJESTIC OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE. CONTENTS Part 1: Safety Information Part 2: Installation
More informationMicrowave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.
HOME ELECTRONICS HE900E/CONV-SS Instruction manual for electronic control microwave oven CONTENTS 1. Specifications 2. Check after unpacking 3. General Safety instructions 4. Special safety instruction
More informationProviding reliable energy-efficient boilers B O I L E R S
Providing reliable energy-efficient boilers B O I L E R S Offering economically viable and sustainable solutions As the overall market sets on the path of environmental sustainability and energy costs
More informationAdvice to consumer Reference 50.1 May 2013. Condensation. Some causes, some advice.
Advice to consumer Reference 50.1 May 2013 Condensation Some causes, some advice. 03 Contents The issue 04 What is condensation 06 The factors governing condensation 09 How double or triple glazing helps
More informationwww.optimumheat.co.uk
The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions
More informationPermanent Ventilators (for the Supply of Combustion
Part - Installation, Safety & Maintenance Permanent Ventilators (for the Supply of Combustion Air) Introduction All heating appliances that produce heat from the combustion of carbon based fuels such as
More informationorlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationMEMORANDUM. General: Foundation:
MEMORANDUM State of Alaska Department of Transportation and Public Facilities Central Region - Division of Construction and Operations Public Facilities Branch TO: Jennifer Murrel DATE: August 19, 2010
More informationThe soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
More informationInstallation Instructions
GC 3 (THREE OVEN) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require.
More information50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
More informationCORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
More informationSBR FIRE RISK ASSESSMENT
SBR FIRE RISK ASSESSMENT Report of audit and inspection Premises Details Occupier Premises Address Premises Description Times premises are in use Use and maximum no. people present The British School of
More informationDealing with damp, condensation and mould growth in your home. www.homesforharingey.org
Dealing with damp, condensation and mould growth in your home www.homesforharingey.org Condensation can cause dampness and mould growth in your home. This looks unpleasant and can increase the risk of
More informationRavelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the
Ravelli Camino Insert Wood Pellet Burning Heater Fire shown installed with a non-combustible floor - no hearth required Ravelli Camino Insert Wood Pellet Fire Installation Specifications Safety testing
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More informationHot Tips For cleaner wood heating. A guide to using your woodheater for maximum heat and minimum pollution
Hot Tips For cleaner wood heating A guide to using your woodheater for maximum heat and minimum pollution Woodheaters the facts are clear A woodheater can be a convenient, economical and attractive way
More informationGuidelines for designing a wood pellet storage facility
Processing / Products No. 12 COFORD 2008 Guidelines for designing a wood pellet storage facility Translated by Pieter D. Kofman 1 These guidelines outline German industry recommendations for the location
More informationUser Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on
You can rely on User Guide and Important Warranty Information Suprima HE Range Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationTable of Contents Interior Exterior
Legal Disclaimer The information contained herein is not intended to be used as a guide for installation or operation of any solid or liquid fuel heating device. Use of this information is at your own
More informationVACUUM CLEANER INSTRUCTION MANUAL
VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,
More informationSolar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
More informationSIM Spartherm Installation Modules NEW
SIM Spartherm Installation Modules NEW The fireplace systems with a stylish finish are durable and modern. Concrete is a great choice of material when you seek to combine safety, elegance and design freedom.
More informationT H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L AT I O N I N S T R U C T I O N S C A R E F U L LY CAR
More informationBoston, Venice, Kodiak. Enviro Wood Fireplace Inserts
Boston, Venice, Kodiak Enviro Wood Fireplace Inserts Why buy an Enviro Wood Insert? Up to 84.7% Efficiency - EPA approved and up to 84.7% efficiency - Enviro makes highly efficient wood inserts to help
More informationHigh Capacity Hot Air Dryer
High Capacity Hot Air Dryer MADE IN AUSTRIA autumn 2015 www.zimmer-austria.com page 1 Hot air dryer type: Compact HC The modular construction of the high efficiency and powerful hot air nozzle dryer is
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationEnergy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
More informationWinter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.
Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Fuel for thought Choosing the right heating system for
More informationFLAMMABLE AND COMBUSTIBLE LIQUIDS
GAP.8.1.0 A Publication of Global Asset Protection Services LLC FLAMMABLE AND COMBUSTIBLE LIQUIDS INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection
More informationEuro Oak Installation
STYLE TIMBER FLOOR Bring your life in style Euro Oak Installation Before Starting Installation Your floor has been manufactured with the best possible care. However we would still advise you to check the
More informationFERMACELL Powerpanel H 2 O for Wet & Moisture affected areas
FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet
More informationCondensation. Some Causes, Some Advice
Condensation Some Causes, Some Advice The Problem Condensation on windows and in conservatories, and the damage it does to paintwork, curtains, wall coverings and window fittings, are problems frequently
More informationMICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
More informationFACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
More informationCommissioning of Heat Producing Appliances Burning Solid Fuel
Building Control Technical Guidance Leaflet No. 15 This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum Commissioning of Heat Producing Appliances Burning Solid
More informationBuilding Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
More informationSPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL
SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL Manufactured in New Zealand by: GLEN DIMPLEX AUSTRALASIA LIMITED PO Box 58-473 Botany Auckland 2163 Ph: 0800
More informationOperating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
More informationSTOVE-BOILER FOR SOLID FUELS Directions for use and assembling
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................
More informationDIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6
More information