Accessory Manual Ventilation Section Model Comfort Circle

Size: px
Start display at page:

Download "Accessory Manual Ventilation Section Model Comfort Circle"

Transcription

1 Accessory Manual Ventilation Section Model Comfort Circle Manual version:. R a

2 Copyright and trademarks All the information and drawings in this manual are the property of Biddle and may not be used (other than for the actual operation of the device), photocopied, duplicated, translated and/or be brought to the attention of third parties without Biddle s prior written permission. The name Biddle is a registered trademark. Warranty and Liability Please refer to [distributor s] Terms of Sales and Delivery for warranty and liability conditions. Biddle and [distributor] exclude liability for consequential loss at all times and under all circumstances. Liability for the contents of this guide However much care might have been taken in ensuring the correctness and, where necessary, completeness of the description of the relevant parts, Biddle disclaims all liability for damage resulting from any inaccuracies and/or deficiencies in this guide. Should you detect any errors or ambiguities in this guide then we would be pleased to hear from you: it helps us to improve our documentation even further. Biddle retains the right to change the specifications stated in this guide. For more information If you have any comments or questions about specific topics relating to this product, please do not hesitate to contact Biddle. Address for [this country]: [local company name] [post address] [place] [country] Address for other countries: Biddle bv P.O. Box 5 NL-988 ZG Kootstertille The Netherlands tel: fax: [local phone number] [local fax number] tel: fax: [ address] export@biddle.nl internet: [website] internet:

3 ACCESSORY MANUAL... Table of Contents Table of Contents Introduction 4. About this manual 4. How to use this manual 4. About the unit 5.4 Safety instructions 7 Installation 8. Safety instructions 8. Delivery check 8. General working method 8.4 Mounting the unit 9.5 Installing the wall duct (accessory) 0.6 Installing the roof duct.7 Connecting air ducts.8 Connecting the servomotor.9 Mounting edge sections (CC VR-CC accessory).0 Mounting the cover (CC VR-CC). Switching on and checking operation Maintenance 4. Cleaning the unit 4. Replacing the filter 4 4 Faults 6 4. Testing the working of the valve 6 4. Checking the valve drive 6 Version:. ( )

4 INTRODUCTION VENTILATION SECTION.. Introduction. About this manual.. General This manual describes the installation, operation and maintenance of the Ventilation Section for the Cassette Unit, type Comfort Circle. This manual should be used in conjunction with the manual of the Cassette Unit, model Comfort Circle. This document contains important information on how to operate the Ventilation Section properly and safely, and on how to prevent any injury and damage. For that reason, please read through this manual thoroughly before carrying out any action with the the unit. This manual describes the installation and operation of standard units. Custom modifications or deviating models are not covered by this manual.. How to use this manual If you are unfamiliar with the Ventilation Section, please read the chapters in sequence. If you are familiar with the unit, you may use this manual as a reference. You can use the Table of Contents and the Index to easily find information... Marginal symbols In this manual the following marginal symbols are used: n Note: Draws your attention to an important part of the text. Read this part of the text carefully. Caution: c If you do not perform this procedure or action correctly, you can damage the unit. So, follow the instructions carefully. 4

5 ACCESSORY MANUAL INTRODUCTION w Warning: If you do not perform this procedure or action correctly, you can cause damage and/or bodily injury. So, follow the instructions carefully. d Danger: This indicates actions which are not permitted. Ignoring this warning can lead to serious damage or accidents which may involve bodily injury. The action concerned may only be performed by qualified technical staff when carrying out maintenance or repair... Related documentation Besides this manual, the following document comes with the unit: wiring / connecting diagram for installation and service purposes.. About the unit 4.. Applications The Ventilation Section is designed to be connected to the cassette unit, model Comfort Circle, ventilation type (CC V). The Ventilation Section has an integrated air valve and filter. Fresh air is sucked in through ducts and a wall grate 4 or a roof cap. Depending on its design, the unit can be integrated into a (suspended) ceiling or be installed above a ceiling... Models and type references Table - provides an overview of the available models of the Ventilation Section and their respective type references. Combined, the type references constitute the type code, for instance, CC 90-VRG4-CC. If some part of the manual applies to certain models only, these will be indicated using their respective type references, for instance: CC VS: Ventilation Section with flat-bed filter, only ventilation; Version:. ( ) 5

6 INTRODUCTION VENTILATION SECTION CC VR-CC: Ventilation Section with possibility of recirculation through plastic cap. Not all combinations are possible. Table - Explanation of the type code TYPE CODE ELEMENT REFERENCE MEANING product series CC general reference for the Comfort Circle series physical size 60 or 90 dimensions of the unit in the ceiling, 600x600mm and 900x900mm ventilation section V Ventilation Section ventilation/ recirculation R no reference: only ventilation; R = ventilation AND recirculation filter S flat-bed filter, filter class G G4 bag-type filter, filter class G4 suction CC no reference: recirculation suction through plenum CC = suction through plastic cap Type CC 90-VRG4-CC Biddle bv Markowei 4 NL-988 HA Kootstertille Code Nº 456/ U 0 V N~ 50 Hz Imax L xxx A Imax L - M 0kg Imax L - Medium Pmotor xxx kw pmax Pheating -.. Type plate The type plate is located on the unit s side, where the valve motor is. This manual refers to the following data on the type plate: Type: full type code of the unit; M: weight of the unit..4 Delivery The unit comes in a box, which contains the following components (depending on the type): Ventilation Section ; cap (for CC VR-CC); suspension profiles...5 Accessories The following optional accessories are available: Suspension kit consisting of Flamco rails and threaded rods; Angle sections for edge finishing in suspended ceilings; Wall grate with plenum; Roof cap with plenum. 6

7 ACCESSORY MANUAL INTRODUCTION..6 Third party delivery In addition to the components mentioned earlier, the following components are required for the proper installation of the Ventilation Section: insulated ducts; ceiling grilles (not for CC VR-CC). These parts are not supplied by Biddle and should be procured from other suppliers..4 Safety instructions w Warning: Do not put any objects in the in- and outlets. w Warning: Do not block the in- and outlets. d Danger: The unit may be opened by qualified technical staff only. Warning: w Switch off the connected Comfort Circle before opening the ventilation section. Version:. ( ) 7

8 INSTALLATION VENTILATION SECTION.. Installation. Safety instructions d Danger: Installation works may be performed by qualified technical staff only. w Warning: Before opening the unit, follow the safety instructions in Section.4.. Delivery check. Check the unit and its packaging for correct delivery. Report any transport damage to the driver and supplier immediately.. Make sure that all parts and components have been supplied (see Section..4). Report any defects to the supplier immediately.. General working method Order of working Biddle recommends the following working method for installing the ventilation section:. Suspend the unit (Section.4).. Connect the unit to the air ducts (Section.7).. Connect the valve drive of the Ventilation Section to the Comfort Circle (Section.8). 4. Turn on the power supply to the Comfort Circle and check the unit s working (Section.). General instructions Some parts of this section are applicable only to certain models. Where this is the case, it will be indicated. If no 8

9 ACCESSORY MANUAL INSTALLATION specific model is referred to, the description applies to all models. n Note: Make sure you perform all installation operations that are required for your unit. Check the type plate and refer to Section.. if you are not sure about the model or type of your unit. n Note: Protect the unit from damage and penetration of dust, cement, etc., throughout the installation. You could, for instance, use the packaging for this purpose..4 Mounting the unit.4. Positioning the unit Make sure that the structure from which the unit is to be suspended can hold the weight of the unit. The weight is specified on the type plate (see Section..). n Note: The direction of the air flow is indicated by arrows on the ventilation section. c Caution: Provide for an inspection hatch in the ceiling if the ventilation section is not fitted in a suspended ceiling. Only for CC VR-CC: Position the unit between the ceiling profiles. The ceiling tiles should not rest on the cover. Instead, use the T-beams of the suspended ceiling or use the optional edge sections (see Section.9)..4. Suspending and securing the unit. Mount Flamco rails and fix M8 threaded rods according to the dimensions in Table -. Make sure the threaded rods are perpendicular.. Mount the suspension profiles to the threaded rods. Version:. ( ) 9

10 INSTALLATION VENTILATION SECTION. Hook the unit into the suspension profiles. 4. You can still change the position of the unit somewhat by moving it in the suspension profiles and Flamco rails. 5. Secure the suspension on both sides using the securing brackets CC VR-CC only: Bring the underside of the unit in line with the T-beams of the ceiling. 4 w Warning: The unit may come down if you do not secure the suspension. Table - Dimensions for suspending the unit REFERENCE TYPE DIMENSIONS c a all models as required b all models a c CC CC b.5 Installing the wall duct (accessory) The wall duct is made up of a wall sleeve and an external wall grate. The wall duct is made up of two parts which are slid into one another. Table - Opening dimensions per wall duct type B A TYPE DIM., A X B WALL THICKNESS CC x 4 mm mm or CC x 4 mm mm. Apply the included expanding foam gasket ("kompriband") around the ventilation opening of the air valve module.. Make an opening in the wall. 0

11 ACCESSORY MANUAL INSTALLATION. Fix the duct sections as you please, e.g., by bricking them in or by fixing them with screws. If using screws, mind their positions: the screws must not hinder the installation of the external grate. n Note: Seal any gaps between sleeve and wall in a draught- and leakage-free manner. 4. Drill the (ø 5mm) grille fixing holes into the flanges of the sleeve section that is fixed to the outer wall. 5. Apply paste onto the inner side of the grille flanges. The paste is to seal off the gap between grille and sleeve in a draught- and leakage-free manner. 6. Fix the grille to the flanges using sheet metal screws. n Note: Place the grille with correctly positioned blades, that is, oriented outward to allow for run-off..6 Installing the roof duct B Tar mastic Timber 70x70 7. Mount the plenum to the wall sleeve. The roof duct is made up of two parts: a roof curb and a roof cap. The roof cap consists of a cover and a sleeve. On delivery, these are attached to one another. Table - Opening dimensions per roof duct type A TYPE CC 60 CC 90 DIM., A X B 00 x 45 mm 50 x 45 mm Version:. ( )

12 INSTALLATION VENTILATION SECTION. Apply the included expanding foam gasket ("kompriband") around the ventilation opening of the air valve module.. Make an opening in the roof.. Make a water-tight curb around the opening. 4. Detach the cap from the sleeve. To do so, loosen the screws in the upper side of the sleeve. 5. Insert the sleeve into the opening. Connect sleeve and curb by fixing screws through the sleeve s inner side. 6. Mount the cap to the sleeve. n Note: Seal any gaps between sleeve and roof in a draught- and leakage-free manner. 7. Mount the plenum to the roof sleeve..7 Connecting air ducts 4. Connect insulated ducts - of a diameter specified in table -4 - to the Ventilation Section, wall or roof duct 4 and the Comfort Circle. Table -4 Duct diameters TYPE DUCT DIAMETER NUMBER CC 60 ø00 mm x CC 90 ø00 mm x 4.8 Connecting the servomotor. Connect the servomotor of the Ventilation Section to the Comfort Circle according to the wiring diagram.

13 ACCESSORY MANUAL INSTALLATION.9 Mounting edge sections (CC VR-CC accessory) If the unit is integrated into a suspended ceiling, the ceiling tiles should not rest on the cover. For correct installation, you may want to use the optional edge sections.. Mount the edge sections to the unit using the enclosed screws.. Position the ceiling tiles upon the edge sections..0 Mounting the cover (CC VR-CC). Remove the air inlet grille by turning it anticlockwise (bayonet catch).. Fit the supplied screws and anti-loss washers into the cover.. Mount the cover into the unit: - Hook the cover into the unit using the metal lips 5; - Tighten the screws in the indicated order Replace the air inlet grille. 4. Switching on and checking operation. Check the connection of the ventilation section s servomotor in the Comfort Circle s electronics module.. Switch on the mains power and/or plug in all connected units.. Switch on the Comfort Circle using the controller. 4. Check the working of the servomotor of the air valve (see Section 4.) Version:. ( )

14 MAINTENANCE VENTILATION SECTION.. Maintenance. Cleaning the unit You can clean the exterior of the unit with a slightly damp cloth and a domestic cleaner. Do not use any solvents.. Replacing the filter w Warning: Make sure no water runs into the unit. d Danger: This may be carried out by qualified staff only... Introduction The filter must be replaced regularly. A dirty filter may lead to inadequate heating as well as a high noise level. The interval at which the filter is to be replaced depends on the local conditions. You may also clean the filter material of the flatbed filter (CC VS) with, for instance, a vacuum cleaner. After some cleanings, however, the filter must be replaced... Monitoring the filter service life The Comfort Circle controller monitors the service life of the filter. In the installer menu (see Section.. of the Comfort Circle manual), you can set the maximum life (the service life on expiry of which the filter is considered dirty)... Replacing the filter (CC VR-CC) 4 4. Switch off the Comfort Circle.. Remove the air inlet grille from the Ventilation Section by turning it anticlockwise (bayonet catch).. Loosen the screws of the cover in the indicated order. Remove the cover. If anti-loss washers were mounted upon installation, the screws stay in the cover. 4. Remove the mounting beam. 4

15 ACCESSORY MANUAL MAINTENANCE Remove the inspection panel 4 by sliding it sideways, in front of the recirculation air intake. 6. Gently pull the filter 5 out of the unit. If you handle the filter too roughly, dust may fall out. 7. Replace the filter with a similar filter. 8. Put back the inspection panel, mounting beam, cover and grille. 9. Reset the service life of the filter by pressing + and - on the Comfort Circle s controller simultaneously...4 Replacing the filter (CC xx-vxx). Switch off the Comfort Circle.. Remove the cover.. Remove the inspection panel by sliding it sideways, in front of the recirculation air intake. 4. Gently pull the filter out of the unit. If you handle the filter too roughly, dust may fall out. 5. Replace the filter with a similar filter. 6. Put back the inspection panel, mounting beam, cover and grille. 7. Reset the service life of the filter by pressing + and - on the Comfort Circle s controller simultaneously. Version:. ( ) 5

16 FAULTS VENTILATION SECTION 4.. Faults 4. Testing the working of the valve You can check the working of the valve via function 5 in the service menu of the Comfort Circle (see Comfort Circle manual, section 8):. Switch on the Comfort Circle.. Compare the average air inlet temperature of the ventilation units (function 5 in the service menu) with the outdoor and indoor temperatures. After switching from ventilating to recirculating, always wait a few minutes before reading the value: - In the ventilation mode, the value should be similar to the outdoor temperature. - In the recirculation mode, the value should be similar to the indoor temperature.. If the readings differ from the outdoor and indoor temperatures, you must check the valve drive. 4. Checking the valve drive Check the valve drive using table 4-. Table 4- Checking the valve drive PROBLEM LIKELY CAUSE WHAT TO DO After switching from ventilating to recirculating, the valve motor does not run The valve motor runs, but the valve does not work. The function of output O is not set properly. The connection between the valve motor and the Comfort Circle is incorrect. The valve motor is not properly mounted to the valve shaft.. Check function 9.5 in the Comfort Circle s installation menu. This value must be 0 (see Comfort Circle manual, section..). Check the wiring between the Comfort Circle and the valve motor.. Check the wiring between terminal X7 and the PCB of the Comfort Circle.. Replace the valve motor.. Tighten the shaft mounting nuts on the valve motor. 6

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally.

Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally. Pet hair clipper Model 96822 Cleaning And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions 06/2011 MBSAW Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper

More information

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version with operating bar with crank electrical version 1. Prerequisite for a correct installation of

More information

San josé OWNER S MANUAL

San josé OWNER S MANUAL San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47) 47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

1000-LB. TRAILER JACK OWNER S MANUAL

1000-LB. TRAILER JACK OWNER S MANUAL 1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Front brakes (FN- 3), servicing

Front brakes (FN- 3), servicing j a t Front brakes (FN- 3), servicing 46-1 Front brakes, servicing Note: Install complete repair kit. After replacing brake pads and before moving vehicle, depress brake pedal several times firmly to properly

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET Be sure to read this installation manual thoroughly prior to installation. If installation methods or non-standard parts not specified in this installation manual are used, accidents or injury may result.

More information

Quadrant Shower Enclosure. Telephone 0844 484 7678. Cleaning. All chrome surfaces should be cleaned using a clean damp cloth.

Quadrant Shower Enclosure. Telephone 0844 484 7678. Cleaning. All chrome surfaces should be cleaned using a clean damp cloth. Cleaning All chrome surfaces should be cleaned using a clean damp cloth. Quadrant Shower Enclosure No abrasive cleaning agents or materials should be used. General glass cleaner can be used for the screen,

More information

Installation Instructions

Installation Instructions VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling

More information

M A N U A L 13-10-05

M A N U A L 13-10-05 Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Reverse Cycle Inverter Split System Air Conditioner

Reverse Cycle Inverter Split System Air Conditioner Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,

More information

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT! Installation Instructions Avalanche XUV Cap IMPORTANT! Read all instructions carefully before commencing any work. Always wear safety equipment. Some installation steps will require two or more installers.

More information

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER \ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installation on caravans and motorhomes provided the roof structure

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Rear wheel brakes, servicing. Стр. 1 из 45. Note: Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information

Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español

Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03 Domestic Air Conditioner SERVICE MANUAL Model HW-05LN03 Feature Anti-mold filter Mechanical control Easy clean filters Slide chassis 4-way airflow direction 2 cool settings, 2 fan settings Serial Number:

More information

DUST COLLECTOR 70 GALLON, 2 HP

DUST COLLECTOR 70 GALLON, 2 HP DUST COLLECTOR 70 GALLON, 2 HP Model 45378 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2001 by Harbor Freight

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

HRU ECO 4. Installer manual

HRU ECO 4. Installer manual HRU ECO 4 Installer manual Table of Contents 1 General information 1 1.1 Introduction 1 1.2 Warranty and liability 1 1.3 Safety 1 2 Technical information 3 2.1 General description 3 2.2 Description of

More information

8" BENCH GRINDER OWNER'S MANUAL

8 BENCH GRINDER OWNER'S MANUAL 8" BENCH GRINDER OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal

More information

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011 OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A

More information

DIGITAL WARMING CABINETS

DIGITAL WARMING CABINETS DIGITAL WARMING CABINETS INSTALLATION-OPERATION-MAINTENANCE USER MANUAL Mac Medical 820 S Mulberry St. Millstadt, IL 62260 California OSHPD Pre-approved (618) 476-3550 phone (618) 476-3337 fax December

More information

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Andersen Electric Window Opener for Andersen Awning and Roof Windows W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of

More information

BULB REPLACEMENT BROCHURE

BULB REPLACEMENT BROCHURE BULB REPLACEMENT BROCHURE Contents Contents Explanation of Symbols 03 Audi A1 04 06 Audi A4 1.9 TDI with Xenon Headlights (from years of manufacture 2000 to 2005) 07 10 Audi A4 (8K5 / 8K2) with Bi-Xenon

More information

Installation Instructions

Installation Instructions Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step

More information

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand 9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration

More information

OWNER S MANUAL Table Tennis Table Patent Pending

OWNER S MANUAL Table Tennis Table Patent Pending OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179

More information

Flue Installation. High Efficiency Condensing Boilers

Flue Installation. High Efficiency Condensing Boilers Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions

More information

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.

More information

Table of Contents. Safety... 3 Specifications... 4 Assembly... 5. Maintenance... 29 Warranty... 32 Parts Lists... 30

Table of Contents. Safety... 3 Specifications... 4 Assembly... 5. Maintenance... 29 Warranty... 32 Parts Lists... 30 Table of Contents Safety... 3 Specifications... 4 Assembly... 5 Maintenance... 29 Warranty... 32 Parts Lists... 30 WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you

More information

Installation instructions of the HEKI 3plus rooflight

Installation instructions of the HEKI 3plus rooflight Installation instructions of the HEKI 3plus rooflight before installing the HEKI 3plus rooflight, please read carefully the installation instructions. 1. Prerequisite for a correct installation of the

More information

Round Housing with Side Ports

Round Housing with Side Ports Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End

More information

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Coolflo Safe Touch Shower Mixing Valve ST20015CP Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

AerAtron. Ceiling fans

AerAtron. Ceiling fans AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Australian edition 2011 Instructions...3 General precautions...3 Location and installation requirements for your fan...3

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair SERVICE MANUAL US Corpus 3G Seat system for electric wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 4, 2014-07 Item No.: 205260-US-0

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

FLEXIT S4 R S6 R S7 R

FLEXIT S4 R S6 R S7 R 94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED. CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT

More information

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2 Installation and Operating Manual p. 23 Radio push button 2 channel: HM-PB-2-WM55-2 1. English edition 10/2013 Documentation 2013 eq-3 Ltd., Hong Kong All rights reserved. No parts of this manual may be

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL DUOTOUR WITH SLIDING DOORS OPERATING MANUAL Duotour DT with Sliding Doors 2 Contents PREFACE... 4 Copyright... 4 Symbols... 4 1 INTRODUCTION... 6 1.1. Options... 6 2 SAFETY FEATURES... 8 2.1. Safety Rail

More information

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17) 17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure

More information

6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU

6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU 6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety

More information

ALI BABA PIANTANA (H165) design SLIDE Studio

ALI BABA PIANTANA (H165) design SLIDE Studio ALI BABA PIANTANA (H165) design SLIDE Studio Dimensioni: Ø 43 h 165 cm Peso: 9,5 Kg Volume imballaggio: 0,268 m 3 Dimensions: Ø 43 h 165 cm Poids: 9,5 Kg Volume emballage: 0,268 m 3 Dimensions: Ø 43 h

More information

LED MOTION ACTIVATED FLOOD LIGHT

LED MOTION ACTIVATED FLOOD LIGHT Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español

More information

Operating Instructions Drill rig DRU160

Operating Instructions Drill rig DRU160 Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual. www.regalo-baby.com

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual. www.regalo-baby.com 149mm 210mm Walk-Thru Assembly Gate MODEL NO: 1161, 1167 Owner s Manual READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF GATE. KEEP INSTRUCTIONS FOR FUTURE USE. www.regalo-baby.com... Regalo International,

More information

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving

More information

AutoDome Easy II. VEZ Series. Mounting Manual

AutoDome Easy II. VEZ Series. Mounting Manual AutoDome Easy II VEZ Series en Mounting Manual AutoDome Easy II Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 2 Unpacking 7 2.1 Parts List 7 3 Description 9 4 Installing a

More information

2-SLICE COOL TOUCH TOASTER

2-SLICE COOL TOUCH TOASTER 2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.

More information

Owner s Manual Read and keep this manual. Patents World Wide

Owner s Manual Read and keep this manual. Patents World Wide Owner s Manual Read and keep this manual. Patents World Wide S & S Industries, Inc., Sarasota, FL, USA www.trail-gator.com Copyright 2008 All Rights Reserved The following manual is provided to assist

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

3/4 PIPE CLAMP WITH STAND

3/4 PIPE CLAMP WITH STAND 3/4 PIPE CLAMP WITH STAND Model 94053 ASSEMBLY AND OPERATING INSTRUCTIONS (3/4 DIAMETER PIPE NOT INCLUDED.) 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46) 46 Brakes - Mechanical Components (Page GR-46) Front brakes Brake pads, removing and installing Brake pads, removing and installing FN 3 brake caliper, servicing FS III brake caliper, servicing Rear wheel

More information

94210E-03 2005-10 L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

94210E-03 2005-10 L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating 94210E-03 2005-10 FLEXIT L4 X W L7 X W User Manual Air Handling Unit Loft Models with water-based heating Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 3 Operation -

More information

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415 Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej

More information

Spetec Laminar Flow Systems. Operating Instructions

Spetec Laminar Flow Systems. Operating Instructions Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for

More information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring

More information

ELECTRIC KNIFE SHARPENER

ELECTRIC KNIFE SHARPENER PRODUCT MANUAL- M109 MODEL 401 ELECTRIC KNIFE SHARPENER Please read thoroughly before operation and keep for future reference Model 401 Knife Sharpener Specifications Model No. #401 Power Requirements

More information

AerAtron. Ceiling fans

AerAtron. Ceiling fans AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN

More information

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades. 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National

More information

AWE Tuning Air/Air Intercooler Kit for 2000-04 Audi 2.7T

AWE Tuning Air/Air Intercooler Kit for 2000-04 Audi 2.7T AWE Tuning Air/Air Intercooler Kit for 2000-04 Audi 2.7T Congratulations on your purchase of the AWE Tuning Intercoolers for your 2.7T Audi. Hundreds of hours of design and operational testing were spent

More information

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For International Prostar ISO 9001:2000 L 2647 Rev. 20090130 WARNING: Only trained technicians should perform

More information

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER... FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE

More information