ENGLISH. User manual.

Size: px
Start display at page:

Download "ENGLISH. User manual."

Transcription

1 ENGLISH User manual Copyright HT ITALIA 2011 Release EN /05/2011

2

3 Table of contents: EN - 1 HT PRECAUTIONS AND SAFETY MEASURES Preliminary instructions During use After use Definition of measurement (overvoltage) category GENERAL DESCRIPTION Measuring average values and TRMS values Definition of true root mean square value and crest factor Harmonics PREPARATION FOR USE Initial checks Instrument power supply Calibration Storage OPERATING INSTRUCTIONS Instrument description Description of the controls Alignment marks Hand protection Indication of the conventional direction of Current Description of the keys Keys F1 F2 F3 F Key H Key Initial screen INSTRUMENT FUNCTIONS Phase detection Settings position: Instrument settings General Date/Time Log InRush Continuity Position V : DC, AC+DC voltage measurement and phase sequence verification DC voltage measurement Key F4 Fnz Hold Backlight AC+DC voltage and Voltage Harmonics measurement Key F2 Par AC+DC voltage Key F4 Fnz in AC+DC voltage measurement Voltage harmonics Key F4 Fnz in Voltage Harmonics measurement Hold Backlight Checking phase sequence and phase concordance with a lead Verification of Phase Sequence Verification of Phase Concordance Position A : DC, AC+DC current measurement DC current measurement Key F4 Fnz Hold Backlight AC+DC current and Current Harmonics measurement Key F2 Par AC+DC current Key F4 Fnz in AC+DC current measurement Current harmonics Key F4 Fnz in Current Harmonics measurement Hold Backlight... 27

4 5.5. Position W : DC, AC+DC power measurement DC power measurement Key F2 Par DC power Key F4 Fnz in DC Power measurement DC voltage and current Key F4 Fnz in DC Voltage and Current measurement DC Energy Hold Backlight Measurement of AC 1P or AC 3P Powers Key F2 Par AC+DC power Pf and dpf Key F4 Fnz in Power or Pf-dPf measurement AC+DC Voltage and Current Key F4 Fnz in AC Voltage and Current measurement Voltage harmonics Current harmonics Key F4 Fnz in Voltage and Current Harmonics measurement AC Energy Hold Backlight Position W : Log, On-Line Scope, SnapShot, MemorY, Download Key F3 Sys Start Log recording On-line Memory SnapShot Download Position Ω : Resistance and continuity measurement Key F4 Fnz Hold Backlight Position InRush A : inrush current measurement Virtual key Zero Key F3 Run Key F4 Mem MAINTENANCE General information Battery replacement Cleaning the instrument End of life TECHNICAL SPECIFICATIONS Technical characteristics Safety standards General characteristics ENVIRONMENT Environmental conditions for use Accessories provided SERVICE Warranty conditions Service APPENDIX THEORETICAL OUTLINE Calculation of powers in AC 1P mode Calculation of powers in AC 3P mode Calculation of powers in DC mode voltage and current harmonics Limit values for harmonics Causes of the presence of harmonics Consequence of the presence of harmonics EN - 2

5 1. PRECAUTIONS AND SAFETY MEASURES HT9022 The instrument has been designed in compliance with directive IEC/EN relevant to electronic measuring instruments. For your safety and in order to prevent damaging the instrument, please carefully follow the procedures described in this manual and read all notes preceded by the symbol with the utmost attention. Before and after carrying out the measurements, carefully observe the following instructions: Do not carry out any voltage or current measurement in humid environments. Do not carry out any measurements in case gas, explosive materials or flammables are present, or in dusty environments. Avoid contact with the circuit being measured if no measurements are being carried out. Avoid contact with exposed metal parts, with unused measuring probes, circuits, etc. Do not carry out any measurement in case you find anomalies in the instrument such as deformation, breaks, substance leaks, absence of display on the screen, etc. Pay special attention when measuring voltages higher than 20V, since a risk of electrical shock exists. In this manual, and on the instrument, the following symbols are used: Warning: observe the instructions given in this manual; an improper use could damage the instrument or its components. High voltage danger: electrical shock hazard. Double-insulated meter AC voltage or current DC voltage or current Connection to earth EN - 3

6 1.1. PRELIMINARY INSTRUCTIONS This clamp has been designed for use in environments of pollution degree 2. It can be used for CURRENT and VOLTAGE measurements on installations with measurement category CAT IV 600V and CAT III 1000V. For a definition of measurement categories, see 1.4. We recommend following the normal safety rules devised by the procedures for carrying out operations on live systems and using the prescribed PPE to protect the user against dangerous currents and the instrument against incorrect use. Only the leads supplied with the instrument guarantee compliance with the safety standards. They must be in good conditions and replaced with identical models, when necessary. In case the lack of warning against the presence of voltage may constitute a danger for the operator: 1. always carry out a continuity measurement before carrying out the measurement of the live system to confirm the correct connection and condition of the leads; 2. before carrying out the critical measurement, carry out a measurement at a power socket where voltage is surely present. As an alternative, make this verification at your site before going to the unknown measuring point. Do not test circuits exceeding the specified current and voltage limits. Check that the battery is correctly inserted. Before connecting the test leads to the circuit to be tested, make sure that the switch is correctly set. Make sure that the LCD display and the switch indicate the same function DURING USE Please carefully read the following recommendations and instructions: WARNING Failure to comply with the Caution notes and/or Instructions may damage the instrument and/or its components or be a source of danger for the operator. Before activating the switch, remove the conductor from the clamp jaw or disconnect the test leads from the circuit under test. When the instrument is connected to the circuit under test, do not touch any unused terminal. Keep your hands always under the hand protection. This protection is always located in a suitable position to guarantee a correct safety distance from possible exposed or live parts (see Fig. 3: hand protection Avoid measuring resistance if external voltages are present. Even if the instrument is protected, excessive voltage could cause a malfunction of the clamp. During current measurement, any other current near the clamp may affect measurement precision. When measuring current, always put the conductor as near as possible to the middle of the clamp jaw, to obtain the most accurate reading. While measuring, if the value or the sign of the quantity being measured remain unchanged, check if the HOLD function is enabled AFTER USE When measurement is complete, switch OFF the instrument. If the instrument is not to be used for a long time, remove the batteries. EN - 4

7 1.4. DEFINITION OF MEASUREMENT (OVERVOLTAGE) CATEGORY Standard CEI 61010: Safety requirements for electrical equipment for measurement, control and laboratory use, Part 1: General requirements defines what measurement category, commonly called overvoltage category, is. In 6.7.4: Measured circuits, circuits are divided into the following measurement categories: (OMISSIS) Measurement category IV is for measurements performed at the source of the low-voltage installation. Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units. Measurement category III is for measurements performed on installations inside buildings. Examples are measurements on distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, stationary motors with permanent connection to fixed installation. Measurement category II is for measurements performed on circuits directly connected to the low-voltage installation. Examples are measurements on household appliances, portable tools and similar equipment. Measurement category I is for measurements performed on circuits not directly connected to MAINS. Examples are measurements on circuits not derived from MAINS, and specially protected (internal) MAINS-derived circuits. In the latter case, transient stresses are variable; for that reason, the standard requires that the transient withstand capability of the equipment is made known to the user. EN - 5

8 2. GENERAL DESCRIPTION The clamp meter HT9022 carries out the following measurements: DC voltage and AC+CD TRMS voltage DC current and AC+CD TRMS current Phase sequence Active, reactive, apparent power and power factor on single-phase and/or balanced three phase systems Active, reactive, apparent energy on single-phase and/or balanced three-phase systems AC voltage harmonics (1 st 25 th ) and THD% up to 75Hz (1 st 8 th above 75Hz) AC current harmonics (1 st 25 th ) and THD% up to 75Hz (1 st 8 th above 75Hz) DC power Frequency on voltage (leads) and current (clamp jaw) Resistance and continuity test with buzzer Electric motor starting currents (INRUSH) Detection of presence of AC voltage with and without contact with in-built sensor in the clamp jaw Each of these functions can be selected using the 7-position selector switch, including an OFF position. Keys F1, F2, F3, F4 e H / are also provided; for their use, please refer to 4.2. EN - 6

9 2.1. MEASURING AVERAGE VALUES AND TRMS VALUES Measuring instruments of alternating quantities are divided into two big families: AVERAGE-VALUE meters: instruments measuring the value of the sole wave at fundamental frequency from 10 to 400Hz TRMS (True Root Mean Square) VALUE meters: instruments measuring the TRMS value of the quantity being tested. In the presence of a perfectly sinusoidal wave, the two families of instruments provide identical results. In the presence of distorted waves, instead, the readings shall differ. Average-value meters provide the RMS value of the sole fundamental wave, TRSM meters, instead, provide the RMS value of the whole wave, including harmonics (within the instrument s bandwidth). Therefore, by measuring the same quantity with instruments from both families, the values obtained are identical only if the wave is perfectly sinusoidal. In case it is distorted, TRMS meters shall provide higher values than the values read by average-value meters DEFINITION OF TRUE ROOT MEAN SQUARE VALUE AND CREST FACTOR The root mean square value of current is defined as follows: "In a time equal to a period, an alternating current with a root mean square value of the intensity of 1A, circulating on a resistor, dissipates the same energy that, during the same time, would have been dissipated by a direct current with the intensity of 1A". This definition results in the numeric expression: t0 +T 1 2 G= g ( t) dt T t0 The root mean square value is indicated with the acronym RMS. The Crest Factor is defined as the relationship between the Peak Value of a signal and its G p RMS value: CF (G)= GRMS This value changes with the signal waveform, for a purely sinusoidal wave it is 2 =1.41. In case of distortion, the Crest Factor takes higher values as wave distortion increases HARMONICS See Appendix (Par.9.4) EN - 7

10 3. PREPARATION FOR USE HT INITIAL CHECKS Before shipping, the instrument has been checked from an electric as well as mechanical point of view. All possible precautions have been taken so that the instrument is delivered undamaged. However, we recommend generally checking the instrument in order to detect possible damage suffered during transport. In case anomalies are found, immediately contact the forwarding agent. We also recommend checking that the packaging contains all components indicated in paragraph 7.3. In case of discrepancy, please contact the Dealer. In case the instrument should be replaced, please carefully follow the instructions given in chapter INSTRUMENT POWER SUPPLY The instrument is supplied by two 1.5V LR03 AAA UM-4 batteries. Battery charge duration is approximately 54 hours of continuous use in Power mode (selector switch to W ). Replace them following the instructions in paragraph CALIBRATION The instrument has the technical specifications described in this manual. The instrument s performance is guaranteed for one year STORAGE In order to guarantee precise measurement, after a long storage time under extreme environmental conditions, wait for the instrument to come back to normal condition (see the environmental specifications contained in before use). EN - 8

11 4. OPERATING INSTRUCTIONS 4.1. INSTRUMENT DESCRIPTION Description of the controls CAPTION: 1. Inductive clamp jaw 2. AC voltage indicator LED 3. Jaw trigger 4. Rotary selector switch 5. Key H / backlight 6. Function keys F1 F2 F3 F4 7. LCD display 8. Input terminal VΩ 9. Input terminal COM Fig. 1: Instrument description Alignment marks Put the conductor as close as possible to the middle of the jaws on the intersection of the indicated marks (see Fig. 2) in order to meet the meter accuracy specifications. CAPTION: 1. Alignment marks 2. Conductor Fig. 2: alignment marks EN - 9

12 Hand protection CAPTION: 1. Hand protection 2. Safe area Fig. 3: hand protection Always keep your hands under the hand protection. This protection is always located in a suitable position to guarantee a correct safety distance from possible exposed or live parts (see Fig. 3) Indication of the conventional direction of Current The photo in Fig. 4: current direction arrow shows an arrow which indicates the conventional direction of current. Fig. 4: current direction arrow 4.2. DESCRIPTION OF THE KEYS Keys F1 F2 F3 F4 Keys F1 - F2 - F3 - F4 take different functions according to the measure set (for detailed information, see the single functions) Key H Short pressing key H activates the function Data HOLD, i.e. the value of the measures quantity is frozen. The symbol "H" is displayed when this function is enabled. This operating mode is disabled when key H is pressed again or the switch is operated Key To improve the readability of the values measured in dark places, the display has been provided with a backlighting function (backlight), which is turned on and off by longpressing key H. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the battery. EN - 10

13 4.3. INITIAL SCREEN When switching on the instrument, the initial screen appears for a few seconds. It shows: the instrument model; the serial number of the instrument; the firmware version in the instrument s memory. HT9022 Sn V WARNING Please note down this information, especially the firmware version, in case it should be necessary to contact the Service Department. After a few seconds, the instrument switches to the selected function. EN - 11

14 5. INSTRUMENT FUNCTIONS HT PHASE DETECTION With the selector switch set to V (Voltage measurement) or A (Current measurement), by taking the end of the clamp jaw near an AC source, the red LED at the base of the clamp jaw will turn on (see Fig. 1 part 2), which indicates that current is present. WARNING Phase detection is not active when the clamp selector switch is set to OFF, SETTINGS, W, Ω, InRush A SETTINGS POSITION: INSTRUMENT SETTINGS By positioning the selector switch to Settings, the screen aside will appear, containing the possible settings of the instrument. Press keys F2, F3 (, ) to move the cursor and key F4 (OK) to confirm the selected item. OK General Date/Time Log InRush Continuity General By selecting General, the screen to the side will appear. Press key F1 (Sel) to move the cursor and keys F2, F3 (, ) to change the selected item. Press key F4 (OK) to save the changes made and go back to the previous screen (see par.5.2). Language: the language of the clamp may be chosen among: Italian, English, Spanish. German, Swedish, Danish, Norwegian, French, Dutch, Portuguese, Finnish and Polish. Sel OK Language: Italian Auto-Off: OFF Auto-Off: the auto power off of the clamp may be set to ON or OFF. If set to ON, the clamp will switch off after 5 minutes after it is last used Date/Time By selecting Date/Time, the screen to the side will appear. Press key F1 (Sel) to move the cursor and keys F2, F3 (, ) to change the selected item. Item Format allows selecting the date and time format between EU (European) or USA (American). Press key F4 (OK) to save the changes made and go back to the previous screen (see par.5.2). Sel OK Year: 11 Month: 01 Day: 19 Hour: 17 Minute: 00 Format: EU EN - 12

15 Log By selecting Log, the screen to the side will appear. Press keys F2, F3 (, ) to change the duration of the integration period. It will take the following values: 1, 5, 10, 30, 60, 120, 300, 600 or 900 seconds. Press key F4 (OK) to save the changes made and go back to the previous screen (see par.5.2) InRush By selecting InRush, the screen to the side will appear. Press key F1 (Sel) to move the cursor and keys F2, F3 (, ) to change the selected item. Press key F4 (OK) to save the changes made and go back to the previous screen (see par.5.2). Thresh: threshold value beyond which the inrush current event is detected and recorded by the instrument. The current value may be set between 5A and 900A in steps of 1A. OK Int.Period: 001 s Sel OK Thres: 080 Window: 1/1 Mode: Fix Window: the value of the inrush current measuring window. The following values are available: 1/1: sampling occurs every half-period; 1/2: sampling occurs one every two half-periods; 1/4: sampling occurs one every four half-periods; Mode: the inrush current measuring mode. Following modes are available: Fix; Var. For details about the measurement of Inrush Currents see par Continuity By selecting Continuity, the screen to the side will appear. Press keys F2, F3 (, ) to change the setting of the resistance limit value below which the buzzer will sound. It may be set between 1Ω and 150Ω in steps of 1Ω. Press key F4 (OK) to save the changes made and go back to the previous screen (see par.5.2). Sel OK Res Lim: 010 Ω EN - 13

16 5.3. POSITION V : DC, AC+DC VOLTAGE MEASUREMENT AND PHASE SEQUENCE VERIFICATION WARNING The maximum DC or AC+DC input voltage is 1000V. When the display shows > 999.9V, it means that the maximum value the clamp is able to measure has been exceeded. Exceeding these limits could result in electrical shocks to the user and damage to the instrument. Mod Par Fnz AC <10.0 Hz By positioning the selector switch to V will appear., the screen to the side ---- V Press key F1 (Mod) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F1, the cursor will scroll through the available items, as follows: AC: AC+DC voltage measurement; DC: DC voltage measurement; Ph Seq: verification of phase sequence; Help: it displays the connection diagram of the instrument to the system; Select the desired mode and press key F4 (OK) to confirm DC voltage measurement Mod Par AC AC DC Ph Seq Help Esc OK <10.0 Hz ---- V Fig. 5: DC voltage measurement EN - 14

17 Insert the red cable into the input lead VΩ and the black cable into the input lead COM (Fig. 5), and position the leads to the desired points of the circuit being tested. Mod Par Fnz DC The screen shows an example of DC Voltage measurement V Key F4 Fnz Press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum value of the measured DC Voltage; Min: it constantly displays the minimum value of the measured DC Voltage; Cr+: it constantly displays the maximum positive crest value; Cr-: it constantly displays the minimum negative crest value; Rst: it deletes all stored Max, Min, Cr+ and Cr- values; Esc: it goes back to a normal measuring mode. Mod Par OK Fnz DC Max Min Cr V Cr- Rst Esc WARNING Note: the measurement of the 4 Max, Min, Cr+ and Cr- values is simultaneous, regardless of the one displayed. By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. Mod Par Fnz Max DC 12.0 V Hold Short pressing key H activates the function Data HOLD. The display shows the message H and the screen of the measurement in progress is frozen. This operating mode is deactivated when key H is pressed again or the switch is operated Backlight Long pressing key H activates or deactivates the display backlight. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the batteries. EN - 15

18 AC+DC voltage and Voltage Harmonics measurement Fig. 6: AC+DC voltage measurement Insert the red cable into the input lead VΩ and the black cable into the input lead COM, and position the leads to the desired points of the circuit being tested (Fig. 6). The voltage and frequency value is shown on the display Key F2 Par Press key F2 (Par) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F2, the cursor will scroll through the available items, as follows: Voltage: it shows the measured Voltage value; Voltage Har: it shows the measured Voltage harmonics; Esc: it closes the drop-down menu. Select the desired parameter and press key F4 (OK) to confirm AC+DC voltage The screen shows an example of AC+DC Voltage measurement. Mod Par OK Voltage AC 50.0 Hz Voltage Har Esc V Mod Par Fnz AC 50.0 Hz V EN - 16

19 Key F4 Fnz in AC+DC voltage measurement While measuring AC+DC voltage, press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum RMS value of Voltage; Min: it constantly displays the minimum RMS value of Voltage; Cr+: it constantly displays the maximum positive crest value; Cr-: it constantly displays the minimum negative crest value; Rst: it deletes all stored Max, Min, Cr+ and Cr- values; Esc: it goes back to a normal measuring mode. By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. Mod Par OK Fnz AC 50.0 Max Hz Min Cr Cr- V Rst Esc Mod Par Fnz Max AC 50.0 Hz V Voltage harmonics The screen shows an example of Voltage Harmonics measurement. By pressing keys F1 ( ) or F3 ( ), it is possible to move the cursor over the graph and to select the harmonic to be measured. It is possible to measure up to the 25 th harmonic, for fundamental frequencies between 10Hz and 75Hz, and up to the 8 th harmonic for fundamental frequencies between 75Hz and 400Hz Key F4 Fnz in Voltage Harmonics measurement While measuring Voltage Harmonics, press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum RMS value of the selected current harmonic; Min: it constantly displays the minimum RMS value of the selected current harmonic; Abs: it displays the absolute value of the harmonics in Volts; Par Fnz H V ThdV 10.0 % Par OK Fnz Max Min Abs % H Rst V Esc ThdV 10.0 % EN - 17

20 %: it displays the value of the harmonics as percentage value with respect to the fundamental; Rst: it deletes all stored Max, Min values; Esc: it goes back to a normal measuring mode. Note: since the menu contains functions with a different meaning (Max-Min and Abs-%), it is necessary to enter the menu twice: once for displaying Abs or % values and another time to enable the Max or Min functions. Par Fnz By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. H V ThdV 10.0 % Max Hold Short pressing key H activates the function Data HOLD. The display shows the message H and the screen of the measurement in progress is frozen. This operating mode is deactivated when key H is pressed again or the switch is operated Backlight Long pressing key H activates or deactivates the display backlight. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the batteries. EN - 18

21 Checking phase sequence and phase concordance with a lead WARNING While measuring, the instrument must be held in the operator s hand. Press key F1 (Mod) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F1 (Mod), the cursor will scroll through the available items. Select Ph Seq and press key F4 (OK) to confirm the selected item. Mod Par AC AC DC Ph Seq Help Esc HT9022 Ok <10.0 Hz ---- V Verification of Phase Sequence. Fig. 7: verification of phase sequence 1. The instrument shows the screen here to the side, and waits for the detection of phase L1. 2. Insert the red cable into input terminal VΩ and connect the red lead to phase L1 (Fig. 7). Mod Ph Seq PH1 Wait Go EN - 19

22 WARNING If the frequency of the measured voltage is lower than 40Hz or higher than 70Hz, the display shows the message F<40 Hz or F>70 Hz and phase detection does not start. 3. When a voltage higher than or equal to 100V is detected, the instrument gives an acoustic signal (buzzer) and the message Meas is shown on the display. Do not press any key and keep the test lead connected to L1 phase cable. Mod Ph Seq PH1 Meas Mod Ph Seq Go Go 4. Once phase L1 acquisition is complete, the displays shows the screen here to the side. Disconnect the test lead from phase L1 cable. Discon. Wait Mod Ph Seq Go 5. The instrument shows the screen here to the side, and waits for the detection of phase L2. Connect the test lead to phase L2 cable. PH2 Wait WARNING If more than 3 seconds elapse before detecting phase L2, the instrument displays the message Time Out. It is necessary to repeat the measuring cycle from the beginning, by pressing key F4 (Go) and starting from step 1 again. Mod Ph Seq Go 6. When a voltage higher than or equal to 100V is detected, the instrument gives an acoustic signal (buzzer) and the message Meas is shown on the display. Do not press any key and keep the test lead connected to L2 phase cable. PH2 Meas EN - 20

23 7. If the two phases, to which the test lead has been connected, are in the correct sequence, the instrument displays the screen here to the side. Should the phase sequence be incorrect, the display shows 132. To start a new measurement, press key F4 (Go) Verification of Phase Concordance Mod Ph Seq 123 Go Fig. 8: verification of Phase Concordance 1. The instrument shows the screen here to the side, and waits for the detection of phase L1. 2. Insert the red cable into input terminal VΩ and connect the red lead to phase L1 of the first sequence (Fig. 8). Mod Ph Seq PH1 Wait Go EN - 21

24 3. When a voltage higher than or equal to 100V is detected, the instrument gives an acoustic signal (buzzer) and the message Meas is shown on the display. Do not press any key and keep the test lead connected to L1 phase cable. Mod Ph Seq PH1 Meas Mod Ph Seq HT9022 Go Go 4. Once phase L1 acquisition is complete, the displays shows the screen here to the side. Disconnect the test lead from phase L1 cable. Discon. Wait Mod Ph Seq Go 5. The instrument shows the screen here to the side, and waits for the detection of the second sequence of phase L1. Connect the test lead to phase L1 of the second sequence. PH2 Wait WARNING If more than 3 seconds elapse before detecting the phase L1 of the second sequence, the instrument displays the message Time Out. It is necessary to repeat the measuring cycle from the beginning, by pressing key F4 (Go) and starting from step 1 again. 6. When a voltage higher than or equal to 100V is detected, the instrument gives an acoustic signal (buzzer) and the message Meas is shown on the display. Do not press any key and keep the test lead connected to L1 phase cable of the second sequence. 7. If there is concordance between the two phases, to which the test lead has been connected, the instrument displays the screen here to the side. Otherwise, it displays 123 or 132. To start a new measurement, press key F4 (Go). Mod Ph Seq PH2 Meas Mod Ph Seq 11- Go Go EN - 22

25 5.4. POSITION A : DC, AC+DC CURRENT MEASUREMENT HT9022 WARNING The maximum measurable DC or AC+DC current is 1000A. When the display shows > 999.9A, it means that the maximum value the clamp is able to measure has been exceeded. Exceeding these limits could result in electrical shocks to the user and damage to the instrument. We recommend holding the clamp respecting the safety area created by the hand protection (see Fig. 3) Mod Par Fnz AC <10.0 Hz By positioning the selector switch to A will appear., the screen to the side ---- A Press key F1 (Mod) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F1, the cursor will scroll through the available items, as follows: AC: AC+DC voltage measurement; DC: DC voltage measurement; Help: it displays the connection between instrument and system; Esc: it closes the drop-down menu. Select the desired mode and press key F4 (OK) to confirm DC current measurement Mod Par AC AC DC Help Esc OK <10.0 Hz ---- A Fig. 9: DC current measurement WARNING Insert the cable in the middle of the clamp jaws, in order to obtain accurate measures. Use the marks as a reference (see Fig. 2). EN - 23

26 Mod Par Fnz DC The screen shows an example of DC current measurement A Key F4 Fnz Press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum value of DC current; Min: it constantly displays the minimum selected value of DC current; Cr+: it constantly displays the maximum positive crest value; Cr-: it constantly displays the minimum negative crest value; Zero: it zeroes the measured DC current; Rst: it deletes all stored Max, Min, Cr+ and Cr- values; Esc: it goes back to a normal measuring mode. Mod Par OK Fnz DC Max Min Cr Cr- A Zero Rst Esc WARNING Note: carry out current zeroing before clamping the conductor; the measurement of the 4 Max, Min, Cr+ and Cr- values is simultaneous, regardless of the one displayed. Mod Par Fnz Max DC By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function A Hold Short pressing key H activates the function Data HOLD. The display shows the message H and the screen of the measurement in progress is frozen. This operating mode is deactivated when key H is pressed again or the switch is operated Backlight Long pressing key H activates or deactivates the display backlight. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the batteries. EN - 24

27 AC+DC current and Current Harmonics measurement Key F2 Par Fig. 10: AC+DC current measurement WARNING Insert the cable in the middle of the clamp jaws, in order to obtain accurate measures. Use the marks as a reference (see Fig. 2). Press key F2 (Par) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F2, the cursor will scroll through the available items, as follows: Current: it shows the measured current value; Current Har: it shows the measured Current harmonics; Esc: it closes the drop-down menu. Select the desired parameter and press key F4 (OK) to confirm AC+DC current Mod Par OK Current AC 50.0 Hz Current Har Esc A Mod Par Fnz AC 50.0 Hz The screen shows an example of AC+DC current measurement A EN - 25

28 Key F4 Fnz in AC+DC current measurement While measuring Current, press key F4 (Fnz) to open the dropdown menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum RMS value of current; Min: it constantly displays the minimum RMS value of current; Cr+: it constantly displays the maximum positive crest value; Cr-: it constantly displays the minimum negative crest value; Zero: it zeroes the average value of the measured current; Rst: it deletes all stored Max, Min, Cr+ and Cr- values; Esc: it goes back to a normal measuring mode. Mod Par OK Fnz AC 50.0 Max Hz Min Cr Cr- A Zero Rst Esc WARNING Note: carry out current zeroing before clamping the conductor. Mod Par Fnz Max AC 50.0 Hz By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function A Current harmonics The screen shows an example of Current Harmonics measurement. By pressing keys F1 ( ) or F3 ( ), it is possible to move the cursor over the graph and to select the harmonic to be measured. It is possible to measure up to the 25 th harmonic, for fundamental frequencies between 10Hz and 75Hz, and up to the 8 th harmonic for fundamental frequencies between 75Hz and 400Hz Key F4 Fnz in Current Harmonics measurement While measuring Current Harmonics, press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum RMS value of the selected current harmonic; Min: it constantly displays the minimum RMS value of the selected current harmonic; Abs: it displays the value of the harmonics in Amperes; Par Fnz H A ThdI 10.0 % Par OK Fnz Max Min Abs % H Rst A Esc ThdI 10.0 % EN - 26

29 %: it displays the value of the harmonics as percentage value with respect to the fundamental; Rst: it deletes all stored Max and Min values; Esc: it goes back to a normal measuring mode. Note: since the menu contains functions with a different meaning (Max-Min and Abs-%), it is necessary to enter the menu twice: once for displaying Abs or % values and another time to enable the Max or Min functions. Par Fnz By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. H A ThdI 10.0 % Max Hold Short pressing key H activates the function Data HOLD. The display shows the message H and the screen of the measurement in progress is frozen. This operating mode is deactivated when key H is pressed again or the switch is operated Backlight Long pressing key H activates or deactivates the display backlight. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the batteries. EN - 27

30 5.5. POSITION W : DC, AC+DC POWER MEASUREMENT WARNING The maximum DC or AC+DC input voltage is 1000V and the maximum measurable DC or AC+DC current is 1000A. Do not measure voltages and currents exceeding the limits given in this manual. Exceeding these limits could result in electrical shocks to the user and damage to the instrument. We recommend holding the clamp respecting the safety area created by the hand protection (see Fig. 3) Mod Par Sys Fnz AC <10.0 Hz By positioning the selector switch to W side will appear., the screen to the ---- kw ---- kvari ---- kva 1P Press key F1 (Mod) to open the drop-down menu shown on the Mod Par Sys OK screen to the side. At each subsequent pressure of key F1, the AC 1P AC <10.0 Hz cursor will scroll through the available items, as follows: AC 3P AC 1P: measurement of AC Powers on single-phase system; DC ---- kw AC 3P: measurement of AC Powers on three-phase Help ---- kvari Esc balanced system; ---- kva DC: DC Power measurement; Help: it displays the connection between instrument and system; Esc: it closes the drop-down menu. Select the desired measuring mode and press key F4 (OK) to confirm. See par.9.1, 9.2 and 9.3 for details about calculation formulas. EN - 28

31 DC power measurement Fig. 11: DC power measurement Insert the red cable into input lead VΩ and the black cable into input lead COM. Position the red lead to + and the black lead to - and insert the + cable into the clamp jaws, respecting the direction of current indicated by the arrow (see Fig. 4) ATTENZIONE Insert the cable in the middle of the clamp jaws, in order to obtain accurate measures. Use the marks as a reference (see Fig. 2) Key F2 Par Press key F2 (Par) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F2, the cursor will scroll through the available items, as follows: Power: it shows the measured Power value; Volt-Curr: it displays the measured Voltage and Current values; Energy: it shows the measured energy value. This measurement is only active when a recording is active (see par ). Esc: it closes the drop-down menu. Select the desired parameter and press key F4 (OK) to confirm. Mod Par Sys Power DC Volt-Curr Energy Esc OK 0.40 kw EN - 29

32 DC power The screen to the side shows an example of DC power measurement. Mod Par Sys Fnz DC 0.40 kw Key F4 Fnz in DC Power measurement While measuring DC Power, press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum value of the measured parameter; Min: it constantly displays the minimum value of the measured parameter; Rst: it deletes all stored Max and Min values; Esc: it goes back to a normal measuring mode. By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. Mod Par OK Fnz DC Max Min Rst Esc 0.40 kw Mod Par Sys Fnz Max DC 0.40 kw DC voltage and current The screen shows an example of DC Voltage and Current measurement. Mod Par Sys Fnz DC 80.0 V 20.0 A EN - 30

33 Key F4 Fnz in DC Voltage and Current measurement While measuring Voltage and Current, press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At DC each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum value of the measured parameter; Min: it constantly displays the minimum value of the measured parameter; Cr+: it constantly displays the maximum positive crest value measured; Cr-: it constantly displays the minimum negative crest value measured; Zero: it zeroes the measured DC current; Rst: it deletes all stored Max, Min, Cr+ and Cr- values; Esc: it goes back to a normal measuring mode. WARNING Note: carry out current zeroing before clamping the conductor. Mod Par OK Fnz Max Min Cr V Cr Zero A Mod Par Sys Fnz Max DC Rst Esc By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function V 20.0 A DC Energy The screen shows an example of DC Energy measurement. Mod Par Sys Fnz DC 2.20 kwh Log Hold Short pressing key H activates the function Data HOLD. The display shows the message H and the screen of the measurement in progress is frozen. This operating mode is deactivated when key H is pressed again or the switch is operated Backlight Long pressing key H activates or deactivates the display backlight. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the batteries. EN - 31

34 Measurement of AC 1P or AC 3P Powers Fig. 12: measurement of AC 1P or AC 3P Powers Insert the red cable into the input lead VΩ and the black cable into the input lead COM, and connect the instrument as described in Fig Key F2 Par WARNING Insert the cable in the middle of the clamp jaws, in order to obtain accurate measures. Use the marks as a reference (see Fig. 2). Press key F2 (Par) to open the drop-down menu shown on the Mod Par Sys OK screen to the side. At each subsequent pressure of key F2, the P-Q-S AC <10.0 Hz cursor will scroll through the available items, as follows: Pf-dPf P-Q-S: it displays the measured values of Active, Reactive ---- Volt-Curr kw and Apparent Power; Voltage Har ---- Pf-dPf: it displays the measured values of Power Factor and Current Har kvari Cosphi; ---- Energy kva Esc Voltage Harm: it shows the measured Voltage Harmonics; Current Harm: it shows the measured Current Harmonics; Energy: it shows the measured energy value. This measurement is only active when a recording is active (see par ). Esc: it closes the drop-down menu. Select the desired parameter and press key F4 (OK) to confirm. EN - 32

35 AC+DC power The screen shows an example of AC+DC Power measurement. Mod Par Sys Fnz AC 50.0 Hz kw 7.68 kvari kva 1P Pf and dpf The screen shows an example of Power Factor and Cosphi measurement. Mod Par Sys Fnz AC 50.0 Hz Pf dpf 0.94 i 0.94 i 1P Key F4 Fnz in Power or Pf-dPf measurement While measuring Power or Pf-dPf, press key F4 (Fnz) to open the drop-down menu shown on the screen to the side. At each subsequent pressure of key F4, the cursor will scroll through the available items, as follows: Max: it constantly displays the maximum value of the measured parameter; Min: it constantly displays the minimum value of the measured parameter; Rst: it deletes all stored Max and Min values; Esc: it goes back to a normal measuring mode. By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. Mod Par OK Fnz AC 50.0 Max Hz Min Rst kw 7.68 kvari Esc kva Mod Par Sys Fnz Max AC 50.0 Hz kw 7.68 kvari kva 1P EN - 33

36 AC+DC Voltage and Current The screen shows an example of AC+DC Voltage and Current measurement. Mod Par Sys Fnz AC 50.0 Hz Key F4 Fnz in AC Voltage and Current measurement V 1P 99.6 A While measuring Voltage and Current, press key F4 (Fnz) to Mod Par OK Fnz open the drop-down menu shown on the screen to the side. At AC 50.0 Max Hz each subsequent pressure of key F4, the cursor will scroll Min through the available items, as follows: Cr+ V Max: it constantly displays the maximum value of the Crmeasured parameter; Zero 99.6 Rst A Min: it constantly displays the minimum value of the Esc measured parameter; Cr+: it constantly displays the maximum positive crest value measured; Cr-: it constantly displays the minimum negative crest value measured; Zero: it zeroes the average value of the measured current; Rst: it deletes all stored Max, Min, Cr+ and Cr- values; Esc: it goes back to a normal measuring mode. WARNING Note: carry out current zeroing before clamping the conductor. Mod Par Sys Fnz Max AC 50.0 Hz By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function V 99.6 A 1P EN - 34

37 Voltage harmonics The screen shows an example of Voltage Harmonics measurement. By pressing keys F1 ( ) or F3 ( ), it is possible to move the cursor over the graph and to select the harmonic to be measured. It is possible to measure up to the 25 th harmonic, for fundamental frequencies between 10Hz and 75Hz, and up to the 8 th harmonic for fundamental frequencies between 75Hz and 400Hz Current harmonics The screen shows an example of Current Harmonics measurement. By pressing keys F1 ( ) or F3 ( ), it is possible to move the cursor over the graph and to select the harmonic to be measured. It is possible to measure up to the 25 th harmonic, for fundamental frequencies between 10Hz and 75Hz, and up to the 8 th harmonic for fundamental frequencies between 75Hz and 400Hz. Par Fnz H V ThdV 2.4 % Par Fnz H A ThdI 10.7 % Key F4 Fnz in Voltage and Current Harmonics measurement While measuring Voltage or Current Harmonics, press key F4 Par OK Fnz (Fnz) to open the drop-down menu shown on the screen to the Max side. At each subsequent pressure of key F4, the cursor will Min scroll through the available items, as follows: Abs Max: it constantly displays the maximum RMS value of the % selected current or voltage harmonic; H Rst A Esc Min: it constantly displays the minimum RMS value of the ThdI 10.0 % selected current or voltage harmonic; Abs: it displays the value of the harmonics in Amperes or Volts; %: it displays the value of the harmonics as percentage value with respect to the fundamental; Rst: it deletes all stored Max and Min values; Esc: it goes back to a normal measuring mode. Note: since the menu contains functions with a different meaning (Max-Min and Abs-%), it is necessary to enter the menu twice: once for displaying Abs or % values and another time to enable the Max or Min functions. Par Fnz By pressing key F3 (OK), the selected item is confirmed. To the side, an example of measurement with active Max function. The display shows the active function. H A ThdI 10.0 % Max EN - 35

38 AC Energy The screen shows an example of AC Energy measurement. The values of Active Energy, Reactive Energy, Inductive Energy and Capacitive Reactive Energy are shown. Mod Par Sys Fnz AC 50.0 Hz 2.24 kwh 0.84 kvarih 0.00 kvarch Log 1P Hold Short pressing key H activates the function Data HOLD. The display shows the message H and the screen of the measurement in progress is frozen. This operating mode is deactivated when key H is pressed again or the switch is operated Backlight Long pressing key H activates or deactivates the display backlight. This function automatically deactivates after approximately 10 seconds after being activated, in order not to discharge the batteries. EN - 36

39 5.6. POSITION W : LOG, ON-LINE SCOPE, SNAPSHOT, MEMORY, DOWNLOAD WARNING The maximum DC or AC+DC input voltage is 1000V and the maximum measurable DC or AC+DC current is 1000A. Do not measure voltages and currents exceeding the limits given in this manual. Exceeding these limits could result in electrical shocks to the user and damage to the instrument. We recommend holding the clamp respecting the safety area created by the hand protection (see Fig. 3). Turn the rotary switch to W. Insert the red cable into the input lead VΩ and the black cable into the input lead COM, and connect the instrument as described in Fig. 12 WARNING Insert the cable in the middle of the clamp jaws, in order to obtain accurate measures. Use the marks as a reference (see Fig. 2) Key F3 Sys While measuring DC, AC 1P or AC 3P Power, press key F3 Mod Par Sys OK (Sys) to open the drop-down menu shown on the screen to the AC Start 50.0 Log Hz side. At each subsequent pressure of key F3, the cursor will Online scroll through the available items, as follows: Memory kw Start Log: it starts a recording of the electrical mains 7.68 SnapShot kvari parameters; Download kva Esc On-line: it starts a Bluetooth On-Line Scope; Memory: it shows the list of the saved data; SnapShot: it carries out an instant saving of the measured parameters; Download: it sets to the mode for downloading the data saved in the memory; Esc: it closes the drop-down menu. By pressing key F4 (OK), the selected item is confirmed. The electrical parameters recorded during a Recording, transmitted during an On-Line Scope or saved in a SnapShot, according to the mode set, are the following: AC 1P:AC 1P: P, Q, S, pf, dpf, V, I, THDV, THDI, hv01..hvxx (xx=25 for fundamental frequency Hz; xx=8 for fundamental frequency Hz); AC 3P: P, Q, S, pf, dpf, V, I, THDV, THDI, hv01..hvxx (xx=25 for fundamental frequency Hz; xx=8 for fundamental frequency Hz); DC: P, V, I Start Log recording Upon confirming the Start Log item, the instrument sets to stand-by and waits for a recording to start. A recording shall be started when reaching the following minute as indicated by the instrument s time. The message Wait is displayed. Mod Par Sys Fnz AC 50.0 Hz kw 7.68 kvari kva Wait 1P 19/01-17:00:35 EN - 37

Model UT201/202: OPERATING MANUAL. Table of Contents

Model UT201/202: OPERATING MANUAL. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness

More information

UT202A Operating Manual. Contents

UT202A Operating Manual. Contents Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols

More information

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES CONTENTS / EN CONTENTS Title Page I. SAFETY INFORMATION...1 II. INTRODUCTION...3 III. SPECIFICATIONS...4 3-1 Environmental Conditions...4

More information

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12 Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of

More information

Model UT33A: OPERATING MANUAL Table of Contents (1)

Model UT33A: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Ground Resistance Clamp On Tester

Ground Resistance Clamp On Tester USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground

More information

Digital Clamp-on DMMs with uncompromising performance

Digital Clamp-on DMMs with uncompromising performance Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy

More information

C.A 8230 ENGLISH. Operating manual

C.A 8230 ENGLISH. Operating manual SINGLE-PHASE POWER QUALITY ANALYSER C.A 8230 ENGLISH Operating manual 1 Meaning of the symbol. Attention: refer to the operating manual before using the instrument. Failure to properly observe or execute

More information

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons Measurement Operation A. DC

More information

Manual Ranging MultiMeter

Manual Ranging MultiMeter Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!

More information

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS

More information

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

GSM Alarm System User Manual

GSM Alarm System User Manual GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

User Guide. Model 380260 Insulation Tester / Megohmmeter

User Guide. Model 380260 Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

CLAMP MULTIMETER F205

CLAMP MULTIMETER F205 CLAMP MULTIMETER F205 ENGLISH User s manual Clamp Multimeter F205 English CONTENTS 1 PRESENTATION... 8 1.1 THE SWITCH... 9 1.2 THE KEYS OF THE KEYPAD... 10 1.3 THE DISPLAY UNIT... 11 1.3.1 The symbols

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1

More information

Three phase circuits

Three phase circuits Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors

More information

i410/i1010 AC/DC Current Clamp

i410/i1010 AC/DC Current Clamp /i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating

More information

Seven function digital multimeter

Seven function digital multimeter Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

Experiment 2 Diode Applications: Rectifiers

Experiment 2 Diode Applications: Rectifiers ECE 3550 - Practicum Fall 2007 Experiment 2 Diode Applications: Rectifiers Objectives 1. To investigate the characteristics of half-wave and full-wave rectifier circuits. 2. To recognize the usefulness

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Ground Resistance Clamp-On Tester

Ground Resistance Clamp-On Tester User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one

More information

Table of Contents. Page 3 4 5 6 8 9 10 11 13 13 14 16 17 19

Table of Contents. Page 3 4 5 6 8 9 10 11 13 13 14 16 17 19 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Multimeter Structure Functional Buttons Display Symbols Measurement

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer

RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4

More information

How To Use A Cdm250 Digital Multimeter

How To Use A Cdm250 Digital Multimeter User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc. Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of

More information

Essential Electrical Concepts

Essential Electrical Concepts Essential Electrical Concepts Introduction Modern vehicles incorporate many electrical and electronic components and systems: Audio Lights Navigation Engine control Transmission control Braking and traction

More information

Fluke Digital Multimeters Solutions for every need

Fluke Digital Multimeters Solutions for every need Fluke Digital Multimeters Solutions for every need How to choose the best DMM for your job Choosing the right digital multimeter (DMM) requires thinking about what you ll be using it for. Evaluate your

More information

The Basics of Digital Multimeters

The Basics of Digital Multimeters IDEAL INDUSTRIES INC. The Basics of Digital Multimeters A guide to help you understand the basic Features and Functions of a Digital Multimeter. Author: Patrick C Elliott Field Sales Engineer IDEAL Industries,

More information

Model UT58A/B/C: OPERATING MANUAL

Model UT58A/B/C: OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols

More information

Electrical Shore Connections / Cold Ironing

Electrical Shore Connections / Cold Ironing STANDARD FOR CERTIFICATION No. 2.25 Electrical Shore Connections / Cold Ironing JULY 2014 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008 CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand

More information

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide Verify that you received the following items in the shipment of your handheld scope: 1 Power cable 1 Li-Ion battery pack, 10.8 V (included

More information

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...

More information

SOLAR300N Rel. 1.03 21/01/10

SOLAR300N Rel. 1.03 21/01/10 Photovoltaic installation certifier + professional network analyzer Pag 1 of 5 1. SOLAR300N MAIN FEATURES SOLAR300N performs all tests on PV plants by using of SOLAR-02 remote unit which, after a preliminary

More information

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter ELECTRICAL INSTRUMENT AND MEASUREMENT Electrical measuring instruments are devices used to measure electrical quantities such as electric current, voltage, resistance, electrical power and energy. MULTIMETERS

More information

323/324/325. Calibration Manual. Clamp Meter

323/324/325. Calibration Manual. Clamp Meter 323/324/325 Clamp Meter Calibration Manual February 2013 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM Multimeter measurements on variable frequency drives using the new Fluke 289 DMM Application Note Editor s note: For similar instructions using the Fluke 87V DMM, reference Fluke article 12345. In the

More information

Microwave Meter. Instruction Manual

Microwave Meter. Instruction Manual Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300

User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300 User Guide 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

IN-OUT Thermometer with Cable Free Sensor and Clock

IN-OUT Thermometer with Cable Free Sensor and Clock IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar

More information

HVAC Clamp Meter. Users Manual

HVAC Clamp Meter. Users Manual 902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 2006-2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies. LIMITED

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Product Information Sheet UH36 Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de

More information

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS v 3 9. v C.A 833B C.A 8334B C.A 8335 9.3 v The experience of the Qualistar ensuring high performance POWER AD EERGY QUALITY AALYSERS 3U 4V 4A L1 L L3 Measure all the necessary voltage, current and power

More information

Table of Contents. Title

Table of Contents. Title Table of Contents Title Page No. INTRODUCTION... 2 SAFETY PRECAUTIONS/WARNINGS... 2 SPECIFICATIONS... 3 CONTROLS AND INDICATORS... 8 TESTING PROCEDURES... 10 AUXILIARY FUNCTIONS... 17 BATTERY AND FUSE

More information

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS 1 EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides

More information

7 FUNCTION DIGITAL MULTIMETER

7 FUNCTION DIGITAL MULTIMETER 7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Titelgrau belassen! Leere Vorlage

Titelgrau belassen! Leere Vorlage Titelgrau belassen! Leere Vorlage MAVOWATT 20 Energy Platform Energy and Power Analyzer MAVOWATT 20 The new Energy and Power Analyzer 2 Klaus-Peter Richter Product Management 10.3.2010 Page 2 Applications

More information

Lab E1: Introduction to Circuits

Lab E1: Introduction to Circuits E1.1 Lab E1: Introduction to Circuits The purpose of the this lab is to introduce you to some basic instrumentation used in electrical circuits. You will learn to use a DC power supply, a digital multimeter

More information

SOLAR I-V Rel. 1.01 20/07/10

SOLAR I-V Rel. 1.01 20/07/10 PV single phase certifier and I-V curve checker Pag 1 of 5 1. SOLAR I-V MAIN FEATURES SOLAR I-V: use as PV certifier SOLAR I-V performs all tests on Single phase PV plants by using of SOLAR-02 remote unit

More information

A Practical Guide to Dielectric Testing

A Practical Guide to Dielectric Testing Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007. Test Method for AC to DC Power Supplies

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007. Test Method for AC to DC Power Supplies ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007 Test Method for AC to DC Power Supplies NOTICE The Society of Cable Telecommunications Engineers (SCTE)

More information

AC Direct Off-Line Power Supplies

AC Direct Off-Line Power Supplies AC Direct Off-Line Power Supplies r Introduction Many DC power supplies found in electronic systems, including those in this Tech School, rectify the 120 volts available at an electric outlet. The initial

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

max 6f / computer max

max 6f / computer max POWER FACTOR REGULATORS computer max max 6f / computer max max 12f Instructions Manual ( M98234601-03-10A ) - 1 - Index 1 INTRODUCTION AND SAFETY RECOMMENDATIONS... 3 1.1 DELIVERY SPOT CHECK... 3 1.2 STARTING

More information

Model 1756 Test Lead Kit

Model 1756 Test Lead Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you

More information

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC. BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping

More information

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03 PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...

More information

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit QUICK START GUIDE Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...

More information

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9 CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY

More information

SUPPLY NETWORK ANALYZER

SUPPLY NETWORK ANALYZER SUPPLY NETWORK ANALYZER AR5-L (Code 7 71 501 ) INSTRUCTION MANUAL ( M98151101-03 / 03E ) (c) CIRCUTOR S.A. -------------- SUPPLY NETWORK ANALYZER AR5-L ----------- Page nº 2 CONTENTS page 1.- BASIC INSTRUCTIONS...4

More information

www.elektroexpressz.hu

www.elektroexpressz.hu www.elektroexpressz.hu 2013 1 UT10 SERIES / UT20 SERIES Modern Pocket - Size Digital Multimeters Pocket-Size Digital Multimeters UNI-T UT10A UT10A DC Voltage 400mV/4V/40V/300 ±(0.8%+1) AC Voltage 4V/40V/300V

More information

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b DIODE CIRCUITS LABORATORY A solid state diode consists of a junction of either dissimilar semiconductors (pn junction diode) or a metal and a semiconductor (Schottky barrier diode). Regardless of the type,

More information

Current Monitoring Kit

Current Monitoring Kit Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added

More information

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5

More information

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS MAKING MODERN LIVING POSSIBLE UniLynx Indoor User Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 2. Function Description 3 Definition

More information

72-7730 72-7732 Intelligent Digital Multimeters

72-7730 72-7732 Intelligent Digital Multimeters 72-7730 72-7732 Intelligent Digital Multimeters Model 72-7730/72-7732 OPERATING MANUAL TABLE OF CONTENTS CHAPTER TITLE PAGE 1. Before You Start Overview Inspection Safety Information Rules For Safe Operation

More information

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies DATE: November 17, 1999 REVISION: AUTHOR: John Merrell Introduction In some short circuit studies, the X/R ratio is ignored when comparing

More information

Electricity Meter in the age of Photovoltaic

Electricity Meter in the age of Photovoltaic Electricity Meter in the age of Photovoltaic Avi Lugassi Introduction In this article we will learn how the electronic Energy Meter can deal with the massive penetration of renewable Photovoltaic energy

More information

Integrating Sound Level Meter and Datalogger

Integrating Sound Level Meter and Datalogger USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable

More information

FREJA 300 Relay Testing System

FREJA 300 Relay Testing System Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15

More information

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal

More information

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents P/N:110401103671 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Event recording (or logging) with a Fluke 287/289 Digital Multimeter

Event recording (or logging) with a Fluke 287/289 Digital Multimeter Event recording (or logging) with a Fluke 287/289 Digital Multimeter Our thanks to Fluke Corp for allowing us to reprint the following article. One of the major features of the Fluke 280 Series digital

More information

VOLTAGE REGULATOR AND PARALLEL OPERATION

VOLTAGE REGULATOR AND PARALLEL OPERATION VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Appliance Multitester C.A 6155

Appliance Multitester C.A 6155 Appliance Multitester C.A 6155 ENGLISH User s manual Appliance Multitester C.A 6155 English CONTENTS 1 GENERAL DESCRIPTION... 9 1.1 WARNINGS... 10 1.2 WARNING MARKINGS ON CONNECTOR PANEL... 11 1.3 STANDARDS

More information

REMOTE TERMOMETER TE 219 LED USER MANUAL

REMOTE TERMOMETER TE 219 LED USER MANUAL INTRODUCTION REMOTE TERMOMETER TE 219 LED USER MANUAL Thank you for purchasing this unit with indoor thermometer, wireless thermometer sensor and radiocontrolled clock. This device is also equipped with

More information

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS

More information

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter AMP-210 AMP-210-EUR 600A AC TRMS Clamp Multimeter AMP-220 AMP-220-EUR 600A AC / DC TRMS Clamp Multimeter AMP-310 AMP-310-EUR 600A AC TRMS Clamp Multimeter AMP-320 AMP-320-EUR 600A AC / DC TRMS Clamp Multimeter

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information