SUNMASTER QS SERIES GRID CONNECTED SOLAR INVERTERS

Size: px
Start display at page:

Download "SUNMASTER QS SERIES GRID CONNECTED SOLAR INVERTERS"

Transcription

1 GRID CONNECTED SOLAR INVERTERS

2 2 MASTERVOLT SOLAR INTRODUCTION Sunmaster QS Series Mastervolt Solar is proud to present the brand new Sunmaster QS grid connected inverter series. The Sunmaster QS series consists of four products, the Sunmaster QS200, QS2000, QS3200 and QS000, providing reliable and flexible solutions for PV systems ranging from 700 to 000Wp. Key points in the design are reliablity and quality, easy installation and full compliance with the most stringent international norms. Due to the advanced High Frequent technology, the QS inverters are efficient, lightweight and compact. The wide input window and multiple MPPTracker inputs allow a wide variety of system designs. Wide input range The Sunmaster QS Series is designed as a full series. Together the four models provide solutions for system sizes between 700 and 000Wp: Sunmaster QS200: Wp Sunmaster QS2000: Wp Sunmaster QS3200: Wp Sunmaster QS000: Wp The input window of the Sunmaster QS inverters is wide, allowing the connection of a large variety and number of both crystalline and amorphous modules. Multiple inputs with individual MPPTrackers The Sunmaster QS3200 and QS000 are equipped with 2 and 3 separate inputs respectively. Every DC input has its individual MPPTracker. This facilitates the connection of strings with a different number of modules in series, different orientations or different module types to a single QS inverter. This feature greatly enlarges the flexibility in PV array configurations: for every situation there is a solution. Easy installation Easy installation: plugs or glands, just as you prefer it (QS200/2000). Installation of the Sunmaster QS inverters is easy and fast. The QS inverter can be connected using either connectors (Multi Contact connectors for the solar side or euro plug for the grid side) or glands, just as you prefer it. Connection of the cabling is easy, because of the easily accesible connection compartment on the front side of the inverter. The compact size and low weight make the mounting of the inverter an easy job. Safe and reliable lasting operation The Sunmaster QS power concept is based on state of the art High Frequent technology, ensuring high efficiency, compact size and low weight. Part of the power conversion is the HF Class II safety transformer, that ensures the Class II galvanic separation between solar and grid side.

3 INTRODUCTION The QS Series is equipped with the QNS anti-islanding device. This device ensures redundant measurement and switch off of the inverter in case of a grid failure. The QNS device is based on measurement of the grid voltage and frequency and complies with all relevant standards. Additionally, the QS inverters can be supplied with a VDE026 compliant ENS unit, that adds the measurement of the grid impedance. The solar side of the system is protected by earth fault detection for installation faults and thermally guarded varistors for lightning induced voltages. Bi-functional LED bar in power mode (left) and fault diagnosis mode (right). Standard: bi-functional LED bar All Sunmaster QS inverters are equipped with a bi-functional LED bar, integrated in the front cover of the unit. The LED bar indicates the amount of converted power during normal operation and the self diagnosis results during system faults or startup. This ensures that the operation of the PV system can be monitored continuously without any extra devices. In case of system errors, the clear indication gives the user information, which can be passed on to the service provider. Integrated QS Display connected to the QS Data Bus. ble, it is possible and easy to connect as well. You are able to connect any type of device in any arbitrary combination in a straight forward way. From a simple local read-out of a single inverter by PC to an extensive system with multiple inverters, wireless displays, data monitoring and remote control: both are easily designed, configured and connected. Central to the concept is the QS Data Bus with the QS Multi-Master protocol, enabling bus wise connection of all devices and automatic configuration of all hardware and communication settings. For further information, please refer to page 6 & 7. Designing your system With the QS Series, Mastervolt Solar provides an optimal inverter solution for any system configuration you might need. The wide input window, full range ( Wp) and features such as the multiple inputs with individual MPPTrackers, gives the designer the freedom he needs to design virtually any kind of system. Systems with several orientations or inclinations, or several string lengths or PV module types, can be connected to one inverter, without loss of yield. Conclusion: the QS series offers optimal design flexibility. To guide you through all design options, Mastervolt Solar offers a PV Design Wizard, that will be available at our website at the end of 200. The only thing you have to do, is to select your module type and enter the desired number (or range) of modules you want to use in your system: the PV Design Wizard will tell you which inverter to use and how to connect it. Refer to page 3 for more details of the design of a system using the QS products Sunmaster QS200 in compact lightweight enclosure. Key:. Compact lightweight enclosure. Industrial design. 2. Clear LED bar with power indication and fault diagnosis. 3. Removable front panel for easy access to the connection compartment. Front panel can be replaced by the optional QS Display (as shown). 4. Equipped with glands as a standard. With DC Multi Contact and AC Europlug connectors available too.. Simple mounting, without opening the inverter. 3 QS Data Monitoring and Control The intuitive approach: when you think it is possible, it is. Part of the family of QS products is an extensive program of communication, display and monitoring facilities. The central philosophy is that you literally should be able to play with the possibilities: when you think a certain configuration is possi- What you can find in this Sunmaster QS brochure The concept 2-3 The family of products 4- Control and monitoring products 6-7 Technology 8-9 Product design, production and quality 0- Product specifications 2-3 Delivery program and availability 4-

4 4 MASTERVOLT SOLAR PRODUCT FAMILY Sunmaster QS Series: a product family With the Sunmaster QS Series Mastervolt offers you a full range of products, with which you can freely and intuitively design any PV system. When you know how to design, install and communicate with one Sunmaster QS, you will know how to work with the whole range. Input specifications are more or less equal for each inverter; the bigger units just have more of the same inputs. Dimensioning per input stays the same: if you know how to do it for one PV system, you will know it for every system size (refer to page 3). The range of communication options works together in an intuitive and straight forward way, and can be combined with any set of Sunmaster QS inverters: communication options for the QS200 are the same as the ones for the QS000. Connection material, installation and commissioning is the same for all units The Sunmaster QS has a compact, and powder coated metal combined inverter during start-up and fault si- light weight enclosure. Mounting is with aluminium extrusion profiles, tuations. The LED bar provides the simple, since the mounting brackets resulting in a strong design, with an user the basic information he needs to are on the outside of the cabinet. The attractive appearance. assess whether his system is working backside of the cabinet leaves enough correctly. room to feed any cabling you need 2 Standard for all Sunmaster QS inver- from the top side of the inverter to the ters is the integrated LED bar with 6 3 The Sunmaster QS inverters use high bottom side. The connection compart- LEDs. The LED bar indicates the frequent technology with small HF ment is situated on the front side of the amount of converted power and the Class II transformers for the galvanic inverter, giving access to the solar and results of the self diagnostics of the separation. The result is a compact, grid connections, the connections for light weight power conversion design communication and the lightning va- on a single power board. The advanta- ristors. The front panel can easily be ges of this single board configuration removed by loosening two screws. The is, that it can be produced and tested front panel can be replaced by a ver- automatically and as a whole. No fur- sion with the integrated QS Display. ther assembly is necessary after testing, The cabinet is constructed from folded reducing the failure rate.

5 PRODUCT FAMILY The front panel of the connection compartment can easily be replaced with a version with the integrated QS display This display is connected to the QS Communication Module, that can be inserted directly in a socket on the main board inside the cabinet. This QS Communication Module also provides the connections to the QS Data Bus for external communication. Read more about data communication, monitoring and control options on page 6 & 7. 4 You can find more information about the used technology on page 8 & 9; an introduction to product development, production and testing can be found on page 0 &. Solar and grid connections can be made in two ways. Either you use glands and the spring terminals on the main board directly, or you use a connector solution, just as you prefer. The Sunmaster QS inverters can be supplied with Multi Contact material for the solar connections and euro plug connectors for the grid connection The Sunmaster QS inverters are controlled by sophisticated micro-controllers and power driver circuitry. These electronics are situated on a separate board, that can be inserted into a socket on the power board. The control board is produced using SMD (Surface Mounted Devices) technology, resulting in a compact design. The control boards are the same for every Sunmaster QS inverter and can be replaced easily when necessary. The control boards can be reprogrammed with updated or customer specified settings. The Sunmaster QS inverters are equipped with anti-islanding devices, that ensure the switch off in case of grid failure. The standard anti-islandig device is the QNS, based on grid voltage and frequency measurement (redundant measurement and switch off); the extended version is the VDE026 compliant ENS unit, which adds a grid impedance measurement to the list. Both the ENS and QNS control electronics are situated on separate control boards. Easy installation: plugs or glands, just as you prefer it (QS3200).

6 6 MASTERVOLT SOLAR MONITORING & CONTROL QS Monitoring & Control The intuitive approach: when you think it is possible, it is. Part of the family of QS products is an extensive program of communication, display and monitoring data in several displaying modes; when a QS Data Monitor is connected to the QS Data Bus, the QS Link Wizard also shows historical data in clear overviews. Data can be exported in Excell or text format. facilities. The central philosophy is that you literally should be able to play with the possibilities: when you think a certain configuration is possible, it is possible and easy to connect as well. You are able to connect any type of device in any arbitrary combination in a straight forward way. From a simple local read-out of a single inverter by PC to an extensive system with multiple inverters, wireless displays, data monitoring and remote control: both are easily designed, configured and connected. Central to the concept is the QS Data Bus with the QS Multi-Master protocol, enabling bus wise connection of all devices and automatic configuration of all hardware and communication settings. All options will become available in Please check the delivery program on page 4 and for availability or check with your local distributor.. QS Data Bus The QS Data Bus is the heart of the communication system of the Sunmaster QS inverters. All devices are connected to this bus in a straightforward way. Each device has a bus in and bus out connection, with RJ4 (standard telephone cable) connection. Physically the bus is a standard 8 pole flat cable with a two way RS48 signal path and auxiliary power supply. The most simple configuration is a point to point configuration, leaving the bus in connection of the first device and the bus out connection of the second device unused. The bus can be extended step by step, by connection of a new cable and device to a free bus in or out connection. The number of devices connected to a single QS Data Bus is standard 32, but can be extended to a maximum of 26. Example of display mode of QS Link Wizard software. 2. QS Link Wizard, the QS System Management Package The QS Link Wizard is a software package, suited for the communication with one or more QS inverters, or one or more locations, through several media. With the QS Link Wizard you can directly communicate with a Sunmaster QS inverter to monitor the data and configure its settings. Or you can use it as a full monitoring and control package to control several PV plants at different locations, with communication connections through different media: direct link, (GSM) modem connection or wireless. The QS Link Wizard shows actual 3. QS Communication Module The QS Communication Module is used to connect a Sunmaster QS inverter to the QS Data Bus. It can be inserted easily in the connection compartment of the inverter and has three connections: two connections for the QS Data Bus (bus in and bus out) and one connection for the optional integrated QS Display in the inverter. 4. QS Display The QS Display is a display that can easily be installed in the Sunmaster QS inverters and enables the user to: Monitor the data from each inverter connected to the QS Data Bus: solar and grid voltage, current, frequency and power, status, total energy and operating hours and set points. Monitor total values of all inverters on the QS Data Bus (total power, energy, status). Adjust set points of the inverters connected to the QS Data Bus.. QS Data Monitor The QS Data Monitor adds memory and monitoring capacity to the bus. It scans the QS Data Bus for available devices and starts monitoring all data automatically, storing 0 minute averages.

7 MONITORING & CONTROL 0. QS Data Transmitter The QS Data transmitter is a wireless transponder of the data that is on the QS Data Bus. It sends bursts of information that can be pic- ked up by several wireless devices. Communication is uni-directional, thus only suited for the display of data. Overview of QS monitoring & control possibilities.. QS Wireless Remote Display Remote stand alone display that displays the data sent by the QS Data Transmitter connected to the QS Data Bus. When a QS Data Monitor is connected to the QS Data Bus, also historical data can be displayed. The QS Data Monitor also provides means to connect and monitor max. two pulse inputs (kwh meters) and one analogue input, 0-00mV (reference cell). The data in the data monitor can be downloaded using the QS Link Wizard software on a computer connected to the QS Data Bus directly (via the PC Link) or at a remote location (via the QS Data Modem, QS GSM Data Modem or QS Data Transmitter/Receiver). The QS Data Monitor can be configured to perform automatic checks of the systems and report to a remote computer (QS Data Modem) or with sms-messages to a cellular phone (QS GSM Data Modem). 6. QS PC Link/ QS PC Link Industrial The PC Link is used to convert the QS Data Bus into a serial connection to a PC. The standard QS PC Link is suited for a small network, i.e. QS Data Bus no longer than 0m, indoor installation and no more than 4 devices connected to the bus. For larger networks you need to use the QS PC Link Industrial. Maximal QS Data Bus length in that case is 000m and maximal no. devices is QS Data Modem The QS Data Modem is an industrial modem used to connect the QS Data Bus to an analogue phone line. The modem is factory set to answer any incoming call and establish a connection with a standard modem, facilitating remote login on the QS Data Bus. The QS Data Modem has a built-in PC Link, making it possible to connect a local PC onto the QS Data Bus at the same time. 8. QS GSM Data Modem The QS GSM Data Modem is an industrial modem used to connect the QS Data Bus to a GSM network. This makes remote communication possible in places where no telephone line is available. 9. QS Data Transmitter/Receiver The QS Data Transmitter/Receiver provides a wireless means of extending the QS Data Bus. A set of two QS Data Transmitter/Receivers behaves similar to an ordinary QS Data Bus cable, i.e. communication is bi-directional. Maximum distance that can be crossed is 800m. 2. QS Wireless Remote Display Large Large info display showing basic data, sent by the QS Data Transmitter. 3. QS Wireless Data Receiver PC connector for the wireless receipt of data from the QS Data Bus. Basic data can be displayed using the QS Link Wizard package. 4. QS RCS Pulse Monitor Basic data monitor for the monitoring of up to pulse inputs (kwh meters). The built-in modem can be configured to send the data automatically by phone line at programmable intervals (i.e. daily, weekly, etc.). Data is stored in daily, weekly and monthly totals. A separate remote software and configuration package is included. 7

8 8 MASTERVOLT SOLAR TECHNOLOGY Advanced technology With each Sunmaster QS you buy, you buy an inverter, designed, produced and tested to last for an extended periode of time. High frequent Mosfet technology combined with high frequent Class II safety transformers, provide safe, efficient and lasting power conversion in a compact, low weight enclosure. Typical Mastervolt novelties, such as QNS redundant grid monitoring, multiple Solar MPPTracker inputs, solar earth fault detection and the transparent extensive monitoring 2 7 options, including wireless communication, give you the tools to provide a solution to every wish you might have. High frequency fly back power converter 2 High frequent Class II safety transformers This converter is the heart of all Sunmaster QS inverters. It is used as a basic building block to build the whole range: two of these converters are in the QS200 and QS2000, four in the QS3200 and six in the QS000. The converter is built from efficient high frequent power Mosfets, high voltage capacitors and two high frequent Class II safety transformers. The converter converts the solar DC voltage into a pure sine wave with a suitable peak voltage and frequency, matching the grid characteristics. The high frequent switching (2,000 times per second) enables the clear build up of a well defined sine, resulting in an extremely low harmonic distortion at the grid side (THD<<3% in compliance with IEEEp929). These transformers not only convert the full power but also provide the galvanic separation between grid and solar side of the inverter. Galvanic separation means that the grid and solar side are not electrically connected, providing a very high level of safety: in case of failure, there is no possible way, in which the grid voltage might be passed onto the solar side and vice versa. The power is transported from solar to grid side using electro-magnetive coupling inside the transformers, which is only present when the QS operates properly. High frequent switching technology makes it possible to use the transformers in a very efficient way. The same power is transported through a much smaller high frequent transformer (weight & size ten times less) than would be possible using conventional low frequent technology. This explains the fact that the QS products are so very compact and low weight. The additional advantage is that the whole unit is assembled on one single board. This makes assembly more easy (less faults) and makes complete in circuit and functional testing possible. 3 Temperature controlled derating The QS inverters are able to convert more power than their nominal specified power for certain periods of time. In principal this power is only limited by the amount of heat production in the inverter. Excess heat is first removed from the cabinet by forced cooling by the low energy, temperature controlled fan. When this is not enough, the power from the array is reduced by a slight increase of the DC voltage, moving the DC voltage away from the MPPT

9 TECHNOLOGY point of the array. 4 Static MPPTracker Typical for the Mastervolt products is the simple but stable and reliable MPPTracker algorithm. The characteristics of a PV array exhibit a strong dependency on irradiation, temperature, cell type, shading, cell defects or mismatch. Especially at start up (low irradiation) and strongly fluctuating circumstances (cloudy days), dynamic trackers might show instable and inefficient behaviour. Mastervolt solved this by implementing a static MPPTracker, that calculates the MPP set point from the measured open circuit voltage of the array (every two seconds). The open circuit voltage of the array is well defined under all circumstances, so the inverter can always set a stable MPP set point, resulting in stable and reliable operation. Multiple Solar inputs with multiple MPPTrackers The QS3200 & 000 are equipped with resp. two and three MPPTracked solar inputs. This makes it possible to connect strings with different number of modules in series, different orientations or different module types. With this feature you can connect virtually any number of modules or any array configuration to the QS inverters. If necessary the QS3200 and QS000 can also be configured to have one single input. 6 Intelligent control The QS inverters are controlled by the central processor on the control board. The processor controls the Mosfets and IGBTs in the input and output converters through dedicated PWM chips, MPPTracker control, self diagnostics and communication with the LED bar, QS Display and QS Data Bus. 7 QNS/ENS redundant grid monitoring The presence of the grid is detected using redundant measurement of grid voltage and frequency (QNS). Redundant means that two independent measuring circuits and micro-controllers measure the grid voltage and frequency independently. When one circuit fails, the remaining circuit will still do the job. In case of grid failure the inverter is switched off in the same redundant way: by a double pole mechanical relay and by means of the solid state switches (Mosfet and IGBT) on the grid side of the inverter. The ENS versions of the grid monitoring add the measurement of the grid impedance to the list. The grid impedance is measured using a capacitor that is switched in parallel to the grid for one cycle. During this cycle the capacitor draws and feeds back a certain amount of blind current. This amount of current is a measure for the grid impedance. This technology uses little power and has no influence on the harmonic behaviour on the grid side. The measurement protocol incorporates features to deal with interference of several ENS units performing measurements on the same grid. The switch off impedance level can be set by a jumper (0, or Ω). 8 Earth fault detection The Solar array works with high DC voltages in a floating configuration. This means that none of the solar connections are grounded. In such systems, the first ground connection is not dangerous, since it carries no current (no closed loop). The second earth connection however closes the loop through ground and can be dangerous. The QS inverters are equipped with earth fault detection, detecting the first ground fault, switching the inverter off. It is indicated to the user that the system has become potentially dangerous (i.e. when a second earth fault is created) and the system should be checked (indication in the LED Bar). 9 Thermally guarded lightning varistors To protect the inverter from lightning induced voltage spikes, both solar and grid connections are protected by varistors. The proper operation of the varistors is checked by continuous monitoring of the temperature. Possible failure of these varistors is indicated to the user through the LED bar indicator. These varistors are located in the connection compartment for easy replacement in case of failure. 0 Communication interface All communications of the QS range are based on the RS48 QS Data Bus. This means that it is possible to connect one or several units with one or several options, such as display(s), computer(s), datamonitor(s) or other devices in a straight forward way. You just extend the QS Data Bus to the new unit or option and connect it. The protocol solves all configuration and communication issues. A Sunmaster QS unit is connected to the QS Data Bus using a simple plug-in communication interface, which is also used for the communication with the integrated display. More information on the extensive communication scheme can be found on pages 6 and 7. 9

10 PRODUCT DEVELOPMENT Product development, production & quality control: a joint effort! In the last decade Mastervolt has been investing heavily in the professionalism, structure and philosophy behind its product development and co-operation with producing partners. How this has resulted in a key philosophy for product development, co-operation and set-up of the testing protocols is presented here. 0 Product Development: taking pride in new innovations and high quality Knowledge is everything. Technology is fun! Product development within Mastervolt is carried out by highly skilled engineers working on the new QS series of products and accessories. To ensure high quality designs and the optimal development of knowledge, the engineering group defined a key philosophy: Our designs are built using state-of-theart technologies, design tools and testing facilities. You can not stay in touch with new developments when working on an island. Mastervolt works together with several design partners, specialists (power electronics and control electronics) The innovative power of the engineering department is essential to our success in the market. On the one hand our engineers closely monitor the requests from the market, while on the other hand there is also plenty of room to explore and develop new innovations. We men- and accredited test institutes to optimise tion the high frequent power concept, The only way to get a high quality designs and the knowledge base of the multiple MPPTrackers in the QS3200 product is to go through the whole group. and QS000 and the smart Soladin 20 development process step by step. inverter concept as results from this Mastervolt works with standardised Evaluation and testing of prototype innovative power. procedures with pre-described design products is a critical part of the develop- steps and evaluation procedures. ment process. Most tests can be performed in house (performance testing, functional testing, EMC, Harmonics and field test at our own array). Some tests, however, are performed in co-operation with external test institutes (ECN, KEMA, Fraunhofer, etc.). These tests concern compliance testing, strain testing and extensive performance testing. Investments in testing equipment and external testing are crucial to the quality Technology is fun! Our product engineers at work. of our product and has the continuous attention of the group. The Sunmaster QS series is manufactured using the most modern production techniques.

11 QUALITY CONTROL Participation in several international product development projects enables us to follow international trends, innovations and markets. Engineering of product ideas towards full grown industrial products, does not only require sound conceptual, electrical and embedded software engineering, but also fast knowledge and experience with production techniques. The quality of a product is strongly determined by the way it is produced: a good design deals with possible problems during production in advance: during the engineering stage. Co-development with our production partners is crucial in this respect. Production: a joint effort All Mastervolt products are produced in close partnership with dedicated production companies. All these companies are ISO900 certified and selected on basis of their experience with state-of-the-art technologies and their capacity to work together with our research and engineering department on the engineering of our products. As explained, co-development with our production partners is crucial to get a high quality design. In a joint effort, design of the products is optimised, production lines and test facilities are set up, before production starts. The Sunmaster QS products consist of power or main boards, with all power electronics, and several control boards, with microprocessors and control electronics. They are assembled at different production lines using different production methods. The main boards are produced on insert machines for the small components and hand-insert lines for larger components (transformers, capacitors, etc.). The control boards are produced using the fast and compact SMD (Surface Mounted Devices) technology. Quality Control The quality of our products is guarded during three stages: During product development: evaluation and testing of the prototype products. During the last development stages and production start-up: co-development with our producing partners. Production: testing protocol for each unit under production. The test protocol during production is depicted in the scheme shown here. Visual inspection When all boards arrive from the production lines, they are visually inspected for incorrect inserts, physical damage of the components and soldering errors. In Circuit Testing (ICT) During the ICTesting, the boards are placed on a needle bed. The needles from the needle bed contact certain points in the circuitry. The ICTesting is first used to test individual components and parts of the circuitry. But, since the whole power conversion, including transformers, is on one board, the ICTest can also be used for a partial functional test. This is one of the benefits of the HF power technology with small transformers that are mounted on the actual board. The ICTest is automated and produces a report of all individual measurements. The ICTest is the most detailed testing method available and is the most crucial test in the whole program. Programming and functional testing The microprocessors on the control board are programmed on the ICTester. After this, their input/output behaviour is tested on a separate functional tester. Anti-Moisture Coating The power board contains high voltage DC parts that are sensitive to moisture. Therefore all power boards of the Sunmaster QS inverters are treated with a special anti-moisture coating (socalled humi-sealing ). Functional Testing After the assembly of the control boards on the power board, the unit is complete. The complete unit is functionally tested, which means that its main input/output behaviour is verified. Input power and current are measured as a function of the input voltage, to verify the input characteristics. DC input is compared to the AC output to calculate and verify efficiency. Harmonic behaviour and anti-islanding is tested and verified. Burn-in Testing Typical to electronics is that for newly produced units the chance on failure is the highest by far within the first hours of operation. After this the failure rate is very low and increases again when Power Boards Visual Inspection In Circuit Testing Anti Moist Coating Assembly Functional Testing Burn In Testing Packaging Control Boards Visual Inspection In Circuit Testing Programming & Functional Testing Strong Evaluation Product Manager Evaluates all information the life time of the unit has expired (typically after years for Mastervolt products). The higher failure rate in the first few hours is explained by the fact that some components might have material defects, that only show up when they operate at full load (i.e. not during functional or ICTesting). The Burn-in Testing is used to solve this problem: the units are tested for 24 hours at full load and at higher ambient temperatures (40-0 C), to literally burn out all component defects, that still might be present in the product. The result is a thoroughly tested product with a very low failure rate. Strong Evaluation One out of every 0 units is tested extensively in our own laboratory. All production testing is repeated and extended with even more detailed testing of components and electrical behaviour. This is to verify whether production is still within its tolerance limits and of constant quality. The strong evaluation is also used to verify the effectiveness of all production tests. Solar Product Manager Information exchange between all processes in the organisation is crucial to improve quality and design. The communication between engineering, service and production is co-ordinated by a dedicated Solar Product Manager. The Product Manager collects all test results from production and strong evaluation testing, assesses service problems and feeds this information back into the engineering and production process. Burn in testing for 24 hours at 0 C ambient.

12 TECHNICAL SPECIFICATIONS 2 General Model Sunmaster QS 200 QS 2000 QS 3200 QS 000 Typical string length Operating temperature 0 C to 0 C Storage temperature -20 C to 70 C Relative humidity Protection degree Noise level Safety class Galvanic isolation cells modules or cells modules max. 9%; PCB has anti-moisture coating IP23 <30 dba class I class II Dimensions 330x220x mm 330x300x mm 43x38x44 mm 600x38x70 mm Weight 4.4 kg 6 kg 0 kg 3 kg Solar input (DC) Nominal power 80W DC@40 C 00W DC@40 C 200W DC@40 C 370W DC@40 C PV power range Wp Wp Wp Wp MPP Tracker MPP Tracker 2 MPP Trackers 3 MPP Trackers MPP voltage range Maximum voltage V DC; p-, m- and a-si 40V DC Nom. rated current@40 C A 7.A 2x 7.A or xa* 3x 7.A or x 22.A* Start-up power 2W, power drawn from the solar side 2W, power drawn from the solar side 4W, power drawn from the solar side W, power drawn from the solar side String connections 2 2 2x2 or x4* 3x2 or x6* DC connector Grid output (AC) glands + PCB spring terminals 4 mm 2 max. or Multi Contact connectors, depending on the model Voltage 230V (window settings and reclosure time depend on model, please refer to the delivery program on page 4 & ) Current (fused) 6.3A 0A 6A 2A Frequency 0 Hz (window settings and reclosure time depend on model, please refer to the delivery program on page 4 & ) Power factor 0.99 THD Stand-by power < rated load; in compliance with IEEE p929 0W (DC voltage controlled relais) European efficiency 92% 92% 93% 93% Maximum efficiency 93% 93% 94% 94% AC connector Safety devices General Island protection Temperature protection DC side AC side Compliance CE/KEMA approval EMC directive Emission Harmonics gland with PCB spring terminals; Europlug connector optional galvanic separation between DC and AC side, by means of a class II HF transformer redundant voltage and frequency window monitoring (QNS); redundant switch off (independent control of 2 pole relais and solid state switch); or ENS (VDE026 compliant), depending on the model power derating at higher ambient temperatures; switch off at 80ºC inverter temperature earth fault detection; over voltage, over current, transients (therm. guarded varistors), over power (temp. controlled derating), reverse polarity protected over current (fuses), transients (varistors) yes/pending EMC 89/336/EEG Immunity EN LV directive Electric safety Monitoring Indicator EN 008-, EN 04, EN 022, VDE 087 class B EN , IEEEp929 LV 73/23/EEC EN 6090 / KEMA approval pending 6 LEDS for indication of power and fault diagnosis External communication insert module for RS48 communication with the QS Data Bus (refer to page 6 & 7) Available data Available set points Monitoring devices UDC; IDC; PDC; UAC; IAC; PAC; FAC; temp; EAC (kwh: class II); total operating hours; status with fault indication MPPTracker settings; QS Data Bus ID; U/F window settings; reset EAC counter The QS products can be linked using the QS Data Bus and connected to an extensive range of communication devices, facilitating direct or remote communication through a telephone line, GSM network or wireless transmissions. Display facilities and data monitoring capabilities (including external pulse inputs and analogue signals) are included in the program. Please refer to page 6 & 7 for more information and to page 4 & for the availability.

13 TECHNICAL CURVES DC Power [W] DC Power [W] QS DC Voltage [V] QS DC Voltage [V] QS3200/000 per MPPT input DC Current [A] DC Current [A] Designing your PV system As can be seen from the specifications, the QS series offers a full range of products for systems from 700 to 000Wp. The solar input window is wide (typically cell modules in series per string) and design flexibility is optimal because of the multiple solar inputs for the QS3200 and QS000. The multiple solar inputs enable you to design a system with virtually any number of modules, with different strings lengths or orientations, without loss of yield due to mismatch. To guide you through this wide variety of options we provide the PV Design Wizard, that will be available at our website from the end of 200 onwards. The graphs on this page show the typical DC power and current behaviour vs. the DC voltage for the QS200, QS2000 and for each input of the QS3200 (two inputs*) and QS000 (three inputs*). We distinguish: The rated current and power at 40 C: this is the maximum power and current that can be converted continuously at an ambient temperature of 40 C. At lower ambient temperatures the rated current and power are higher. The maximum power and current: these are the limits at which the current and power are limited by the control software to prevent damage. The maximum current and power level can typically be maintained for 0 to minutes. After this time the inverter will derate the DC power depending on inverter temperature, eventually to the level of the rated power and current. 3 DC Power [W] Efficiency [%] DC Voltage [V] Rated DC C Max. DC power Rated DC C Max. DC current Efficiency curves Sunmaster QS DC-Power [W] modules (72 cells) 7 modules (72 cells) 9 modules (72 cells) DC Current [A] When determining the number of modules per string and number of strings per input, please check the following: (example: string of 9 modules (20Wp, Umpp: 33V; Uoc: 42V; Impp:3.6A) connected to the QS200) Methodology Example. Determine the amount of overdimensioning of the system you allow, i.e. how much bigger is the PV array (in Wp) allowed to be in respect to the rated power of the inverter (in W). This factor is typically somewhere between,2 and, The open circuit voltage (Voc) at STC per module multiplied by the number of modules in series should be higher than 200VDC 9 x 42= and lower than 390VDC. 378 Ok 3. When you are connecting more strings, the string length of strings connected to the same input, should be equal. 4. When you have determined the number of modules per string, determine the maximum power point voltage (Umpp) at STC per string: Umpp per module, multiplied by the number of modules 9 x 33= in series. Look in the graph of the QS inverter you are going to use 297V and determine the rated current at this Umpp. ~ 2,8A. The total maximum power point current (Impp) you can connect 2.8 x.3= to an input should not exceed the rated current (see 3.) multiplied 3.64 > 3.6 by the overdimensioning factor you allow (see.). OK * Important: as can be seen from the specifications, the QS3200 and QS000 can be configured to have two respectively three inputs or to have one single input. The characteristics of this single input configuration are similar to the characteristics per input, but with power and current numbers multiplied by two (QS3200) or three (QS000). Ok

14 DELIVERY PROGRAMME Delivery program QS Range product article no. group name model description Sunmaster QS QNS p/m-si SB Sunmaster QS 200 QNS p/m-si SC Sunmaster QS 2000 QNS p/m-si SD Sunmaster QS 3200 QNS p/m-si SE Sunmaster QS 000 QNS p/m-si AC Side: VAC; Hz. Anti islanding: QNS; reclosure time 60s. Module type: poly and mono crystalline. AC/DC connection: glands with PCB connectors. Sunmaster QS ENS p/m-si SB Sunmaster QS 200 ENS p/m-si SC Sunmaster QS 2000 ENS p/m-si SD Sunmaster QS 3200 ENS p/m-si SE Sunmaster QS 000 ENS p/m-si AC Side: 96-23VAC; Hz. Anti islanding: ENS; reclosure time 0s. Module type: poly and mono crystalline. AC/DC connection: glands (AC); MultiContact (DC), glands are included seperately. 4 Sunmaster QS It QNS p/m-si SB Sunmaster QS 200 It QNS p/m-si SC Sunmaster QS 2000 It QNS p/m-si SD Sunmaster QS 3200 It QNS p/m-si SE Sunmaster QS 000 It QNS p/m-si Sunmaster QS QNS a-si SB Sunmaster QS 200 QNS a-si SC Sunmaster QS 2000 QNS a-si SD Sunmaster QS 3200 QNS a-si SE Sunmaster QS 000 QNS a-si Sunmaster QS ENS a-si SB Sunmaster QS 200 ENS a-si SC Sunmaster QS 2000 ENS a-si SD Sunmaster QS 3200 ENS a-si SE Sunmaster QS 000 ENS a-si AC Side: VAC; Hz. Anti islanding: QNS; reclosure time 300s. Module type: poly and mono crystalline. AC/DC connection: glands with PCB connectors. AC Side: VAC; Hz. Anti islanding: QNS; reclosure time 60s. Module type: amorphous. AC/DC connection: glands with PCB connectors. AC Side: 96-23VAC; Hz. Anti islanding: ENS; reclosure time 0s. Module type: amorphous. AC/DC connection: glands (AC); MultiContact (DC) (glands are included seperately). Sunmaster QS It QNS a-si SB Sunmaster QS 200 It QNS a-si SC Sunmaster QS 2000 It QNS a-si SD Sunmaster QS 3200 It QNS a-si SE Sunmaster QS 000 It QNS a-si AC Side: VAC; Hz. Anti islanding: QNS; reclosure time 300s. Module type: amorphous. AC/DC connection: glands with PCB connectors. Dummy models SX Sunmaster QS 200 Dummy SX Sunmaster QS 2000 Dummy SX Sunmaster QS 3200 Dummy SX Sunmaster QS 000 Dummy

15 DELIVERY PROGRAMME product article no. group name model description Connectivity SN Multi Contact DC connector set Add on Multi Contact connector set QS 200/2000 (2 strings) with cable and sealing caps SN Multi Contact DC connector set QS 3200 (4 strings) SN Multi Contact DC connector set QS 000 (6 strings) SO Euro plug AC connector set QS 200 Add on Euro Plug AC connector set with cable SO Euro plug AC connector set QS SO Euro plug AC connector set QS SO Euro plug AC connector set QS 000 Communication & monitoring SP QS RS48 Communication Module Insert print for the QS powerboard, connection to QS Data Bus and QS display SN QS Data Modem Modem for connection QS Data Bus to phoneline SN QS GSM Data Modem Modem for connection QS Data Bus to GSM network SN QS Data Monitor Extended datalogging capacity for QS Data Bus SR QS PC Link Connection of a small QS Data Bus network to a PC SN QS PC Link Industrial Connection of a large QS Data Bus network to a PC SR QS Data Transmitter Unidirectional wireless data transmitter for QS Data Bus SR QS Data Receiver Unidirectional wireless data receiver for QS Data Bus SN QS Data Receiver/Transmitter Bi-directional wireless extension of the QS Data Bus SN QS RCS Modem Stand alone modem with programmable pulse input counter SZ QS Link Wizard The QS systems management software package SF QS Display QS 200 Add on display in the inverter; interacts with QS Data Bus SF QS Display QS SF QS Display QS SF QS Display QS SG QS Wireless Remote Display small Remote display with wireless unidirect. link to QS Data Bus R SG QS Wireless Remote Display large SO QS Data Bus 0.m QS Data Bus 8 pole flat cable with RJ4 connectors SO QS Data Bus 6m SO QS Data Bus 0m SO QS Data Bus m SO QS Data Bus cable 00m QS Data Bus 8 pole flat cable SO RJ4 connectors 00p QS Data Bus connectors SO RJ4 Crimping Tool QS Data Bus connector crimping tool

16 Connect to the sun. Sunmaster QS series - advanced HF power concept - fast and safe installation - broad Vdc window Wp solar power Mastervolt Solar offers a powerful combination of premium quality, ongoing innovation and inherent reliability. We develop and produce grid connected inverters from 00W to 2 kw, according to the most stringent international regulations. Mastervolt Solar inverters are all backed up by excellent service and support. Version no. UK Mastervolt Solar, Snijdersbergweg 93, 0 AN Amsterdam, The Netherlands, tel: , fax: , solar@mastervolt.com,

ABB central inverters PVS800 100 to 1000 kw

ABB central inverters PVS800 100 to 1000 kw Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

Fronius IG Plus. The next generation grid-connected PV inverter

Fronius IG Plus. The next generation grid-connected PV inverter Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:

More information

How To Make A Fronius Cl Power Inverter

How To Make A Fronius Cl Power Inverter Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

INVERTER SYSTEM PRODUCT BROCHURE

INVERTER SYSTEM PRODUCT BROCHURE INVERTER SYSTEM PRODUCT BROCHURE DC AC the SolaX inverter The solar inverter is a critical technological component that is the heart of any PV plant. A solar inverter, or PV inverter, converts the variable

More information

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract. TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION Abstract This application note describes the four quadrant mode of operation of a linear AC Power

More information

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000 Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL JSI Series Single Phase String Inverter Features JSI-500TL JSI-000TL JSI-500TL High performance string inverters ØFrom.5KW to 6.0KW ØWide PV input voltage range ØRapid MPPT tracking technology ØSuperior

More information

PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS

PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS Michael Müller 1, Roland Bründlinger 2, Ortwin Arz 1, Werner Miller 1, Joachim Schulz 2, Georg Lauss 2 1. STECA ELEKTRONIK GMBH, Mammostr.

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

YSmart Technology Co.,Ltd

YSmart Technology Co.,Ltd YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Sunmaster XS4300/ XS3200/ XS2000

Sunmaster XS4300/ XS3200/ XS2000 USER S AND INSTALLATION MANUAL / GEBRUIKERS- EN INSTALLATIEHANDLEIDING BEDIENUNGS- UND INSTALLATIONSANLEITUNG / MANUEL UTILISATEURS ET D INSTALLATION MANUAL DEL USUARIO Y DE INSTALACIÓN / MANUALE DI USO

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Everything you need for protection scheme testing

Everything you need for protection scheme testing Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full

More information

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw Solar inverters ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw ABB s central inverters are extremely scalable, modular-inverter systems that are based on 55kW modular

More information

Your own power station: For continuous power

Your own power station: For continuous power Mass Combi Ultra Your own power station: For continuous power Compact and lightweight inverter/battery charger Seamless switching between generator and grid Separate second charger Integrated MPPT solar

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Satcon Solstice 100 kw System Solution

Satcon Solstice 100 kw System Solution Clean power. SDMS-0100-208-LNU SDMS-0100-240-LNU SDMS-0100-480-LNU 5-12% mprovement in Total Energy Harvest 20-25% Reduction in Balance of System Expense The industry s first complete power-harvesting

More information

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W Solar inverters ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W MICRO The ABB MICRO inverter system is the perfect solution suitable for photovoltaic applications when flexibility

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd. DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

SolarMax P series The power package for residential solar plants

SolarMax P series The power package for residential solar plants SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

MINIMAT-EC-Servo Screwdriver Spindles

MINIMAT-EC-Servo Screwdriver Spindles Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range

More information

IO-RM3 3-Stage Relay Module

IO-RM3 3-Stage Relay Module Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Re-defining the utility-scale inverter

Re-defining the utility-scale inverter Re-defining the utility-scale inverter We believe in green energy in the ability to meet and contribute to growing power demands while supporting a smart grid that serves a smart society. Solution at a

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi

More information

E E V R E - R S - O S L O A L R

E E V R E - R S - O S L O A L R Solar Eye User Manual Edition JIANGSU EVER-SOLAR NEW ENERGY CO., LTD. Revision History Date Edition Specification 17/08/2011 1.0 Create File 02/09/2011 1.1 Add Micro SD function description www.ever-solar.com

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

SOLAR POWER CONDITIONER Service Manual

SOLAR POWER CONDITIONER Service Manual SOLAR POWER CONDITIONER Service Manual JH-1600E Released in May 2009 Version: V00 TABLE OF CONTS Important Service Safety Precautions 2 Warning.. 3 General Information.. 5 1 System Overview... 5 2 Overview

More information

HYBRID POWER SYSTEMS for TELECOM applications

HYBRID POWER SYSTEMS for TELECOM applications HYBRID POWER SYSTEMS HYBRID POWER SYSTEMS HYBRID POWER SYSTEM WITH AC GENSET PRAMAC has developed a new solution that allow coupling a traditional AC constant speed diesel genset with an energy storage

More information

Sunmaster XL 10K/15K

Sunmaster XL 10K/15K USER S AND INSTALLATION MANUAL / GEBRUIKERS- EN INSTALLATIEHANDLEIDING BEDIENUNGS- UND INSTALLATIONSANLEITUNG / MANUEL UTILISATEURS ET D INSTALLATION MANUAL DEL USUARIO Y DE INSTALACIÓN / MANUALE DI USO

More information

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production

More information

High Power Programmable DC Power Supplies PVS Series

High Power Programmable DC Power Supplies PVS Series Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient

More information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM

Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

FAQ s on Siemens Magmeters

FAQ s on Siemens Magmeters FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Stroom voor elke toepassing

Stroom voor elke toepassing ELECTRICITY: ALWAYS & EVERYWHERE With VICTRON Phoenix MultiPlus and a HONDA Generator An intelligent combination with endless possibilities! Electrical appliances that increase on board comfort, such as

More information

4.0 UPS dedicated to ICT for unmatched energy savings

4.0 UPS dedicated to ICT for unmatched energy savings 4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.

More information

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Product Information Sheet UH36 Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

GROWATT NEW ENERGY CO.,LTD. service@ginverter.com GR - UM - 001-07

GROWATT NEW ENERGY CO.,LTD. service@ginverter.com GR - UM - 001-07 GROWATT NEW ENERGY CO.,LTD service@ginverter.com GR - UM - 00-07 Content Congratulations on choosing our Grid PV Inverter, Our Grid PV Inverter are a highly reliable products due to their innovative design

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Indoor / Outdoor Antenna

Indoor / Outdoor Antenna z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302

More information

MODEL 2202IQ (1991-MSRP $549.00)

MODEL 2202IQ (1991-MSRP $549.00) F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR

More information

AC modules: past, present and future

AC modules: past, present and future H. Oldenkamp 1, I.J. de Jong 2 1 2 NKF KABEL B.V., Electronics Group, P.O. Box 26, 2600 MC Delft, The Netherlands, Telephone: +31 15 2605616, Fax: +31 15 2605714, Email: Henk.Oldenkamp@nkf.nl OKE-Services,

More information

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic

More information

EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER

EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER A willingness to install east-west orientated photovoltaic (PV) systems has lacked in the past. Nowadays, however, interest in installing

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

MIDNITE SOLAR AND SOLAR WASHINGTON

MIDNITE SOLAR AND SOLAR WASHINGTON MIDNITE SOLAR AND SOLAR WASHINGTON CHARGE CONTROLLERS 30 amp MPPT with load control for small systems, boats and RV s THE KID THE KID LED MODES The KID has a three LED bar graph plus four status LEDs that

More information