1 OVERLL DIMENSIONS 36" (91.5) 25 1/8" (63.8) 23 7/8" (60.7) 1 7/8" (4.8) *84" (213.4) *8 (212.1) 69 5/8" (176.8) *73 1/4" (186.1) SPECIFICTIONS Overall Width Overall Height Overall Depth Clearance Cutout Width 36" (91.4 cm) 84" (213.4 cm) 25 3/8" (64.45 cm) 36 3/4" (93.4 cm) 35 1/2" (90.2 cm) Cutout Height /2" ( cm) Cutout Depth Plumbing Requirements Shipping Weight 24" (61 cm) 1/4" OD copper tubing or GE SmartConnect kit 569 lb *3" (7.6) FRONT VIEW * Shipping height. Use leveling legs and wheels for maximum 1" height adjustment from shipping height. 3 (89.0) Case width *3 1/4" (8.3) ** llow 2 (63.5) min clearance for 130 door swing SIDE VIEW TTENTION ELECTRICIN: 115 volt 60Hz., 15 or 20 amp power supply is required. n inidividual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. 36 3/4" (93.4) TOP VIEW ** llow 4" (10.2) min clearance to a wall for 90 door swing **These units are equipped with a 2-position door stop. The factory set 130 door swing can be adjusted to 90 if clearance to adjacent cabinets or walls is restricted. llow 1 minimum clearance to wall for pan removal. If the 90 door stop position is used, pan access is maintained but pan removal is restricted. Dimensions in parentheses are in centimeters unless otherwise noted. ctual product dimension may vary due to manufacturing tolerances.
2 STNDRD INSTLLTION 2 5/16" (5.9) *8 min *84 1/2" max ( ) *Trim will overlap additional 7/16" nti-tip racket 35 1/2" (90.2) ELEC. 5 1/2" (14.0) 9" (22.9) WTER (9.0) 81 1/2" (207.0) 75 1/2" (191.8 ) From floor to bottom of electrical area Use two additional hole locations at end of brackets 3 1/8" (7.9) 24" (61.0 ) 7/16" (1.1) Trim overlap 1 1/2" (3.8) CL racket mounted into vertical wall studs Ensure holes selected are centered on the studs Wall Studs W Mounting the junction box in this location will also allow for front accessability through access panel. Water supply area. WRNING: The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the antitip system you must use the product installation instructions. The information below applies to all installation constructions: wall bracket, bolts and toggles will be supplied with the unit. The bolts will be used to attach bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs. The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. In installation opening, measure 81 ½ from floor and draw a horizontal line. Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32.5 of installation opening to ensure 2 wall studs are penetrated. The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied L bolts. SIDE VIEW INSTLLED WITH NTI-TIP RCKET FRONT VIEW OF CUTOUT WITH NTI-TIP RCKET See Installation Instructions for detailed instructions.
3 CUSTOM SIDE PNELS F 1 7/8" (4.8) 24" (61.0) 3/16" (.5) *84 *84" (213.4) *Depending on installation height F Side panels must be used whenever the sides of the refrigerator will be exposed. The 1/4 side panels will slip into the side case trim. Secure the panels to the refrigerator with stick-on hook and loop fastener strips. Order the side panels from the cabinet manufacturer. *3" - 4" ( ) *Depending on installation height 2 9/16" (6.5)
4 DUL INSTLLTIONS 2 5/16" (5.9) 71 1/2" (181.6) Finished Width 24 3/16" (61.4) ELEC. 5 1/2" ELEC. 5 1/2" (13.9) (13.9) 24" (61.0) Min. Cutout Depth separate 115V, 60Hz, 15- or 20-amp power supply is recommended for each product. dditional cutout width may be required when side panels are used. 8 min 84 1/2" max ( ) Finished Opening 9" (22.9) WTER (9.0) 9" (22.9) FRONT VIEW WTER (9.0) 75 1/2" (191.8 ) From floor to bottom of electrical area SIDE VIEW W In a side-by-side installation of a leftand-right-hand door swing product, 1 clearance between the units is required. Order ZUGSS2 European, ZUGPP2 Professional or ZUG2 custom panel unified grille kit for one continuous grille panel. C In a side-by-side installation with same door swing, allow 2 minimum clearance between the products to prevent the door swing interference. llow 15 minimum to a wall to achieve full drawer extension and pan removal. dditional clearances are required when using custom panels and handles. NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel kits will not fit this installation. D In a side-by-side installation with right and left door hinges together, allow 5 minimum clearance between the two products to prevent one door from striking the other. dditional clearances required when using custom panels and handles. NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel kits will not fit this installation. DUL PRODUCT CLERNCES 2 (63.5) min To wall 1" (2.5) 2 (63.5) min To wall 2" min (5.1) 1 (38.1) min To wall 130 swing 130 swing min C D
5 1/4" FRMED PNEL DIMENSIONS Grille Panel PNEL SSEMLY CROSS SECTION Trim Trimmed refrigerators are designed to be customized with decorative panels. Fieldinstalled custom door and grille panels are required. Supplied Handles 1/4" Framed Panel 1/4 Framed Panels: You may install 1/4"- thick custom panels from your cabinet manufacturer. The decorative panels slide into the factory- installed trim. Maximum total panel weight: panel 67 lbs. Grille panel 11 lbs Panel C PNEL DIMENSIONS C 1/4" Framed Panel 33 7/8" 8 7/8" 69 5/16" 3/4" OVERLY PNEL DIMENSIONS Grille Panel Panel C PNEL SSEMLY CROSS SECTION 3/4" Overlay Panel Supplied Handles PNEL DIMENSIONS C 1/4" acker Panel 33 7/8" 8 7/8" 69 5/16".10" Spacer Panel 32 1/2" 7 5/8" 67 15/16" 3/4" Overlay Panel 34 1/8" 9" 69 9/16" " +.7 = 1.10" Total Panel Thickness Trim 1/4" acker Panel.10" Spacer Panel 3/4 Overlay Panels: For a more custom appearance, overlay panels may be installed on trimmed models. The overlay panel must be secured to a 1/4"-thick backer panel which slides into the trim. spacer panel 0.10" thick must be placed between the overlay and backer panels. Center each panel over the other. ssemble the panels with glue and screws. Screws must be countersunk into the backer panel. NOTE: Left-to-right offset is not always equal to top-to-bottom offset. Maximum total panel weight: panel 67 lbs. Grille panel 11 lbs Handles: The supplied handles can be adjusted to accommodate both framed or overlay panels. Custom handles of your choice, supplied by your cabinet maker, can also be installed. ZKHPSS1: Professional Tubular Stainless Steel Handle designed to fit 3/4" overlay panels. Kits include one handle /2" long. ZKHSS2: European tubular stainless steel handle designed to fit 3/4" overlay panels. Kits include one handle /4" long.
6 FETURES ND ENEFITS Custom Panel Model - Can be personalized with cabinet-matching panels and handles Enhanced Temperature Management System - With precise electronic controls and thermistors, maintains ideal storage conditions for fresh foods Concealed Halogen Lighting System - Illuminates contents without compromising space Humidity-Controlled Compartments and Sealed Snack Drawers - Help preserve the freshness of foods djustable Spillproof Glass Shelves - Easily accommodate party trays and platters Sealed Dairy Compartment - Locks in freshness Gallon-Size in - Holds milk containers, two-liter bottles and pitchers R
REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional
Standard Features & Accessories All models include Capacity accommodates up to 150 full-size bottles o 84 H./24 D. Exclusive TriTemp storage system o Three independent temperature zones o Settings are
More informationREFRIGERATION. Standard Features & Accessories. Model Options. Freestanding 36 W. French-Door. Models include. VCFF136* Professional.
Standard Features & Accessories Models include Total capacity 19.6 cu. ft. (545.7 L) 72 H./D. Cabinet depth design (D. side panels) integrates with surrounding cabinetry fit for replacement of most existing
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationFrench Door Refrigerator E23BC78IPS professional series
French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling
More informationInstallation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine
Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications
More informationIntegral Kit Instructions
Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has
More informationBUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS
UILT-IN MIROWVE OVEN INSTLLTION INSTRUTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm) This product is suitable for use above electric or gas built-in ovens, and below non-vented electric or gas cooktops.
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationINSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.
ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST
More informationBase Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
More informationELECTRIC CONVECTION BUILT-IN OVEN
ENGLISH ESPAÑOL FRANÇAIS INSTALLATION MANUAL ELECTRIC CONVECTION BUILT-IN OVEN Please read these instructions thoroughly before installing and operating the oven. LWS3081ST LWD3081ST LSWS305ST LSWD305ST
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationDIY CABINET REFACING INSTALLATION GUIDE
DIY CABINET REFACING INSTALLATION GUIDE CABINET REFACING INSTALLATION Are you ready to reface your outdated cabinets? This guide will show you how to install your new Facelifters Cabinet Refacing Products
More informationSliding Barn Door Hardware Installation Instructions BALDUR and ODEN
Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview
More informationSliding Door Hardware Installation Instructions
Sliding Door Hardware Installation Instructions Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview ff All Krown Lab sliding
More informationINSTALLATION INSTRUCTIONS
door frames Engineered product systems INSTALLATION INSTRUCTIONS door frames MINIMALIST DOOR FRAME Fry Reglet Flush Door frames are designed for use with 3 5/8 studs with ½ drywall both sides (4 5/8 throat
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationINSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
INSTLLTION INSTRUTIONS 24" (61.0 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements...
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More information42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
More informationHow you select and where to install me! Kitchen BE CAREFUL OF FOLLOWING PARAMETERS : A- Plumbing space needed (specifically the height).
Environment, recycling, selective collect Today, to convert a house to recycling, a house should have necessary methods and tools. Richelieu, always ahead of practical solutions, offers management and
More informationInstallation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)
RE EFORE INSTLLING UNIT For SLO3 ir onditoner (8,000~2,000 TU) INSTLLTION WRNINGS N UTION arefully read the installation manual before beginning. Follow each step as shown. Observe all local, state, and
More informationDESK CABINETS & BOOKSHELVES
142 : Desk Base Desk Base Cabinets File Drawer Base Cabinet Desk Base Cabinet 1 Factory Installed Wastebasket FDB1821 DWBT1821 Desk Base cabinets are 12 to 24 wide, 28 1 2 high and 20 3 4 or 24 deep. Cathedral
More informationBLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationInstallation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
More informationHOW TO INSTALL A BEAUTIFUL NEW KITCHEN
HOW TO INSTALL A BEAUTIFUL NEW KITCHEN Easy to follow step-by-step kitchen cabinet installation TOOL AND MATERIAL LIST Hammer Pry bar Screwdriver Phillips Flathead Level Tape measure Pencil Straight edge
More informationInstallation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
More informationDIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS
DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS TheRTAStore.com STEP 1: CLEAR A WORK SPACE Place your RTA cabinet panels on a smooth, scratch resistant surface in a large, open area. (Some people like to
More informationK. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
More informationEXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique
EXTeR US G L A S S - With patented design, able to join technology and quality of materials with a charming shape. Unique thanks to its outstanding loading capability with 150 kg maximum weight and height
More informationWren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets...
tra 1 Index Wren Kitchens Installation Tips... 3 Carefully check your kitchen delivery... 4 Measuring out and marking up... 5 Fitting the base cabinets... 6 Fitting the corner cabinets... 7 The 972mm or
More informationPremier & Deluxe 3-Season Room Sliding Glass Door
DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen
More informationVanity Cabinets. Width Height Depth. 12 to 60 31 1 8 to 84 18 to 20 3 4 (Reduced Depth optional on select cabinets)
147 Dimensions Width Height Depth 12 to 60 31 1 8 to 84 18 to 20 3 4 (Reduced Depth optional on select cabinets) SKU Coding VSB 36 BUTT Cabinet Type width in inches Door Type (e.g., VSB=) Construction
More informationCalvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
More informationKITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE
FITTING YOUR KITCHEN GUIDE How to mark out a kitchen PAGE 1 Before starting on the installation, measure 870mm from the lowest point of the floor and mark a datum line around the room to indicate where
More informationAU-110 racking guide NBXPN: 023
AU-110 racking guide NBXPN: 023 1. Overview NIMBOXX AU-110 Rack Installation This guide provides setup instructions for installing your NIMBOXX AU-110 in a rack. Following these steps in the order given
More information19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
More informationglass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
More informationPUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
More informationGENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)
GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES 1. PROTECTIVE SCREENS (a) Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic) Typically, 15 kg m -2 (1.3 mm) sheet lead or its shielding
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationInstallation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
More informationSSG PRODUCTS FOR SHIPS AND OFFSHORE
6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these
More informationHeavy Glass Frameless Shower Door With Return Panel
202 Anderson Ave., elvue, KS 66407 Phone: 800-669-9867 Fax: 800-393-6699 www.onyxcollection.com Heavy Glass Frameless Shower Door With Return Panel Full Showers with Return ench Seat with Return FRLSDRPL-0116
More informationCanvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions
Y Parts Included: Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Tools Required: Power Driver Drill Bit (Determined by fastener) Driver Bit (Determined by fastener)
More informationMEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series
INSTALLATION INSTRUCTIONS MEDIUM FLAT PANEL DISPLAY STATIC MOUNT The static mount accommodates medium flat panel displays weighing up to 125 lbs (57 kgs). The teardrop holes in the mount allow for quick
More informationREDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES
REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel
More informationWood Sound Retardant Door Hardware Information Bulletin
overly overly 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: overly@overly.com DOOR COMPANY Wood Sound Retardant Door Hardware
More informationIMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
More informationSteel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
More informationPRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372
PRO PANELS by MD Enterprises the artist s choice in display designed by artists, for artists 1-800-525-4159 www.propanels.com voice: 214-350-5765 fax: 214-350-7372 MD Enterprises 1-800-525-4159 voice:
More informationInformation Technology Solutions
Information Technology Solutions Aluminum Sliding Door Assembly Instructions Shield Doors & Windows Bi-fold Door Assembly Instructions For Support Please Call 03 8339 2252 Aluminum Sliding Door Assembly
More informationINSTALLS IN MINUTES! Canada s #1 Selling Security Bars. No need for special tools!
INSTLLS IN MINUTES! No need for special tools! Canada s #1 Selling Security Bars Why you need MR.GOODBR security bars 2 FETURES ND BENEFITS visual deterrent, lets thieves know you are not an easy target
More informationInstallation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationCLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
More informationRack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
More informationMounting Printed Circut Boards (PCB) Toll Free: 1.866.849.3911 (US & Canada) Fax: 902.567.3336 Email: info@protocasedesigner.com
Toll Free: 1.866.849.3911 (US & Canada) Fax: 902.567.3336 Email: info@protocasedesigner.com Designing enclosures to mount printed circuit boards (PCB) using Protocase Designer (All dimensions are in inches)
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationCluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationDell P Series Monitor VESA Mounting Bracket Installation Instructions
Dell P Series Monitor VESA Mounting Bracket Installation Instructions The VESA mounting bracket enables a Wyse cloud client to be mounted to the Dell P Series Monitor and the Dell E24 Monitor. The cloud
More informationRack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
More informationInstallation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls
Installation Manual Toilet Partitions, Dressing Compartments & Shower Stalls Metpar Corp 95 State Street, Westbury, New York, USA, 11590 Tel: 516-333-2600 Fax: 516-333-2618 Internet: http://www.metpar.com
More informationSchluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
More informationCORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationLinkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
More informationCan you design a frameless shower enclosure that doesn't leak?
Can you design a frameless shower enclosure that doesn't leak? With proper design and installation frameless shower enclosures should not have any problems with water leakage, but they are not 100 percent
More informationCHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationSeismic Installation for Attic Storage System
Your Performance Partner Seismic Installation for Storage System CONTENTS SSafety Precautions................................. 2 Required Tools..................................... 2 Parts and Fastener
More informationCeramic Glass Electric Galley Ranges
Ceramic Glass Electric Galley Ranges OWNER S MANUAL Models # 65335, 65336, 75331, 75332 Read all instructions and warnings before operating. Force 10 Manufacturing Corporation Unit A 19169 21 st Ave Surrey,
More informationscreens U N D E R S TA N D I N G S C R E E N S...9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...9 3
U N D E R S TA N D I N G S C R E E N S...........................9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...................9 3 P L A N N I N G W I T H A D D - O N S C R E E N S.....................9
More informationArchitect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
More informationDesk Cabinets & Bookshelves
125 Desk Cabinets & Book Dimensions SKU Coding Width Height Depth 12 to 36 28 1 2 to 96 12 to 24 (Reduced Depth optional on select cabinets) DDO 18 21 Cabinet Type width depth (e.g., DDO= in inches in
More informationNo Phone Line II-48 System
Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase
More informationFRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
More informationFIXED PLATE INSTALLATION FOR STRAIGHT TRUCKS
FIXED PLTE INSTLLTION FOR STRIGHT TRUCKS For staight trucks only, not for trailers. For single stage and two stage mast forklifts. Dump Bodies require special construction, contact for specific instructions.
More informationSlides and Drawers. The right collection
Slides and Drawers The right collection 1Technical Details Drawer Runners Carrying capacity Kg. Static load Dynamic load Pag. 01 Concealed Runners Excel N Excel N Excel N Excel N650 Excel N Excel PlugIn,
More informationRack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances
This set of instructions applies to racking and rail kit installation for 6XX and above. The Rack Mounting Instructions section below provides information on installing the SC825 chassis into a rack unit
More informationMETER REQUIREMENTS GENERAL REQUIREMENTS SECTION D
12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section
More information39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
More informationVinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions
New Construction Installation Instructions EPLACEMENT Installation Instructions Page 2 of 6 New Contruction Installation Instructions 1. Frame rough opening equal to window call out size. ough opening
More informationAlpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery
Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service
More informationInstallation Instructions
Installation Instructions Free-Standing Side-by-Side Stainless Steel Refrigerator ZFSB23D SS ZFSB25D SS monogram.com Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully.
More informationmajestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base
majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base These Instructions are for a left and right handed unit. The diagrams show a left
More informationClad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
More informationPRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
More informationSun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
More information2. The Laboratory Fume Hood Specification Catalog Select the style and size hoods appropriate for your layout and laboratory use.
TABLE OF CONTENTS How to Specify... 3 Introduction to Fisher Hamilton Stainless Steel Laboratory Casework... 4 5 Stainless Steel Casework Options Menu... 6 Base Cabinets... 7 17 Sitting Height Cabinets...
More informationINSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
More informationARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors
Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height
More informationMGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
More informationILLUSION FRAMELESS SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS
PREPARATION Approximate Installation Time: Tools Required for Installation: 60 minutes Hacksaw Electric Drill 3/16 Masonry Bit Pencil/Felt tip pen Safety Glasses Measuring Tape Masking Tape Standard Screw
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More informationHALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
More information