1 PS4100 Hardware Maintenance Guide Version 1.0

2 Copyright 2011 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks and registered trademarks mentioned herein are the property of their respective owners. Information in this document is subject to change without notice. Reproduction in any manner whatsoever without the written permission of Dell is strictly forbidden. June 2011 Part Number: EN-R1

3 Table of Contents 1 Basic Storage Array Information... 1 Notes, Cautions, and Warnings...1 Recommended Tools...1 Protecting Hardware...1 Chassis Types...2 Array Features...2 The Bezel...2 Installing the Bezel...2 Front-Panel Features and Indicators...3 Back-Panel Features and Indicators...4 Shutting Down and Restarting an Array Maintaining Drives... 7 About Drive Types...7 Identifying Failed Drives...7 Interpreting Drive LEDs...7 Array Behavior When a Drive Fails...8 Drive Handling Requirements...9 Drive Installation Guidelines and Restrictions...9 Removing a 2.5-inch Drive...10 Installing a 2.5-inch Drive...11 Removing a 3.5-inch Drive...12 Installing a 3.5-inch Drive...13 Installing a Drive Blank...14 Removing a Drive Blank Maintaining Control Modules Control Module Features...17 iii

4 Table of Contents About Control Module Configurations...17 Interpreting Control Module LEDs...18 Identifying Control Module Failures...19 Understanding Failover Behavior...19 Maintaining Control Module Firmware...20 Control Module Handling Requirements...20 About the Standby On/Off Button...21 Replacing a Control Module...22 Removing a Control Module...22 Installing a Control Module...23 Replacing the MicroSD Card...24 Removing the MicroSD Card...25 Inserting the MicroSD Card...26 Advanced Networking Options...26 Configuring the Management Port Maintaining Power Supply and Cooling Modules About AC Power Supplies...29 Power Supply LEDs...29 Removing a Power Supply and Cooling Module...30 Installing a Power Supply and Cooling Module Troubleshooting Your Array Safety First For You and Your array...35 Obtaining Technical Support and Customer Service...35 Determining Service Tag Information...35 Obtaining Component Diagnostics...36 Troubleshooting Array Startup Failure...36 Troubleshooting Loss of Communication...36 Troubleshooting Array Connections...36 iv

5 Table of Contents Troubleshooting External Connections...36 Troubleshooting Power Supply and Cooling Modules...36 Troubleshooting Array Cooling Problems...37 Troubleshooting Control Modules...37 Troubleshooting Hard Drives...38 Index v

6

7 1 Basic Storage Array Information This chapter includes information about the location and basic operation of the replaceable components in a storage array, tools and equipment you will need, protecting hardware from electrostatic discharge, and power on and off operations. Notes, Cautions, and Warnings A NOTE indicates important information that helps you make better use of your system. A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. A WARNING indicates a potential for property damage, personal injury, or death. Recommended Tools You will need the following items to perform the procedures in this section: Bezel key Wrist grounding strap Protecting Hardware Protect a PS Series array from electrostatic discharge. When handling array hardware, make sure you use an electrostatic wrist strap or a similar form of protection. To use a wrist strap: 1. Connect the steel snap on the coil cord to the stud on the elastic band. See Figure 1. Figure 1 Using an Electrostatic Wrist Strap 2. Fit the band closely around your wrist. 1

8 Basic Storage Array Information 3. Connect the banana plug to ground, or attach the plug to the alligator clip and connect the clip to a grounded device such as an ESD mat or the metal frame of a grounded piece of equipment. Chassis Types The PS4100 array is available in two different chassis types: A 2U chassis with inch drives, installed vertically A 2U chassis with inch drives, installed horizontally Array Features The array has LEDs and other features on both the front and the back. The Bezel The bezel is an optional trim panel that attaches to the front of the array to ensure the physical security of the array. You must remove the bezel to access and maintain the drives. The bezel has a label that identifies the array model number. Removing the Bezel The steps for removing the bezel are the same for all array models. 1. Using the bezel key, unlock the bezel. 2. Holding the bezel, lift the latch on the left side of the bezel and swing the left side away from the array. 3. Lift the right side of the bezel off the right side of the array. 4. Set the bezel aside. Installing the Bezel The steps for installing the bezel are the same for all the array models. 1. Hook the right end of the bezel onto the right side of the chassis. 2. Swing the left end of the bezel towards the left side of the chassis. 3. Press the bezel into place until the release latch closes. 4. Using the key provided, lock the bezel and store the key in a safe place. 2

9 Basic Storage Array Information Figure 2 Installing the Bezel Front-Panel Features and Indicators The front of a PS4100, without the bezel, is shown in Figure 3 and Figure 4. Table 1 describes the front panel features. Figure 3 Front Panel Features and Indicators (3.5-inch Drives) Figure 4 Front Panel Features and Indicators (2.5-inch Drives) 3

10 Basic Storage Array Information Table 1 Front Panel Feature Descriptions Item Indicator Icon Description 1 Array status The array status LED lights when the array power is on. LED Off No power. Steady blue Array status is OK. Blinking blue Administrator request to identify the array (see the Group Administration online help). Steady amber Critical status. Blinking amber Warning. 2 Power LED The power LED is ON when at least one power supply is supplying power to the array. Off No power (both power supplies are off or not present). Steady green Array has at least one power supply providing power. 3 Drive Release Latch None Blinking green Array is in power standby mode. Enables you to remove a drive from the array. Note: The LEDs are part of a built-in chassis control panel that is not hot-swappable and can be replaced only by support personnel. During the array power-up sequence, these LEDs will cycle through different states until the array is fully started and the active control module has been determined. Back-Panel Features and Indicators The back of a PS4100 is shown in Figure 5. Table 2 describes the back panel features. Figure 5 Back-Panel Features 4

11 Basic Storage Array Information Table 2 Array Back Panel Features Item Feature Identifier Description 1 Power switches (one None on each power supply) The power switch controls the power supply output to the array. 2 Power supply and cooling fan module 3 Type 12 Control Module 4 Control Module Release Lever PSU0 (left) PSU1 (right) CM0 (top) CM1 (bottom) None 700 Watt power supply. For more information, see Power Supply LEDs on page 29. The control module provides: a data path between the array and the applications using the storage array management functions for your array Enables you to remove the control module from the array. Shutting Down and Restarting an Array A PS Series array includes redundant, hot-swappable drives, power supplies, and control modules (in a dual control module array). You can remove a redundant component without affecting operation if a functioning component is available. Otherwise, it is recommended that you cleanly shut down the array and turn off power before removing a component. Note: When an array is shut down, any volumes with data on the array will be set offline until the array is successfully restarted. This may affect initiators that are connected to the volumes. 1. Do one of the following: Use telnet or SSH to connect to a functioning IP address assigned to a network interface on the array. Do not connect to the group IP address. Use the null modem cable shipped with the array to connect to the serial port on the active control module (ACT LED is green) to a console or a computer running a terminal emulator. Make sure the serial line characteristics are as follows: 9600 baud One STOP bit No parity 8 data bits No flow control 2. Log in to an account with read-write access, such as the grpadmin account. 5

12 Basic Storage Array Information 3. Enter the shutdown command, as shown next. login: grpadmin Password: Welcome to Group Manager Copyright Dell, Inc. group1> shutdown If you are using a serial connection to shut down an array, it is safe to turn off power when the press any key message appears. (Pressing any key will restart both control modules.) If you are using a network connection, the session will be disconnected before the array is fully shut down. Confirm that the ACT LED on each control module is off (not lit) before turning off power to the array. After performing array maintenance, you can turn on power to the array. When the array restart completes, the member and volumes will be set online. 6

13 2 Maintaining Drives You can replace a failed drive while the array remains running. About Drive Types Depending on your configuration, your array supports up to inch SAS drives or up to inch SAS drives in internal drive bays. Drives are connected to a backplane through drive carriers and are hot-swappable. Drives are supplied in a carrier that is keyed to fit into specific array models, and cannot be installed in other Dell arrays or arrays not from Dell Inc. Identifying Failed Drives A drive failure is indicated by: LEDs on the drive. See Interpreting Drive LEDs. A message on the console, in the event log, or in the Group Manager Alarms panel. Indications in the Group Manager Member Disks window or the CLI member select show disks command output. Behind the bezel, arrays have a label showing the drive numbering for that specific array model: In arrays with 2.5-inch drives (installed vertically in a row), the drives are numbered 0-23, left to right. In arrays with 3.5-inch drives (installed horizontally), the drives are numbered from left to right and top to bottom, starting with 0 on the upper left side. Table 3 shows the drive order for the 3.5-inch drives. Table inch Drive Numbering Interpreting Drive LEDs The LEDs on a 3.5-inch drive are shown in Figure 6. The LEDs on a 2.5-inch drive are shown in Figure 7. Drive LED states are described in Table 4. 7

14 Maintaining Drives Figure 6 LEDs on 3.5-inch Drives Figure 7 LEDs on 2.5-inch Drives Table 4 Drive LED States Description Indicator States Drive activity indicator (ACT LED) Blinking green: Drive is busy Steady green: No drive activity Drive status indicator (PWR LED) Green: Drive OK Amber: Drive failed Off: No power to drive Array Behavior When a Drive Fails How an array handles a drive failure depends on whether a spare drive is available and whether the RAID set containing the failed drive is degraded. For example: If a spare drive is available, the array automatically uses it to replace the failed drive. Performance is normal after reconstruction completes. If a spare drive is not available the RAID set will become degraded (except a RAID 6 set). Performance may be impaired. A RAID 6 set can survive two simultaneous drive failures. 8

15 Maintaining Drives If a spare drive is not available and the failed drive is in a RAID set that is already degraded, data may be lost and must be recovered from a backup. If a drive fails, replace it. Do not re-install it in the array. Drive Handling Requirements Handle drives as follows: Store drives properly. Store replacement drives in the packaging in which they were shipped. Do not stack drives or place anything on top of a drive. Protect drives from electrostatic discharge. Wear an electrostatic wrist strap when handling a drive, unless it is protected from electrostatic discharge. See Protecting Hardware on page 1. Handle drives carefully. Hold a drive only by the plastic part of the carrier or the handle. Do not drop or jolt a drive or force a drive into a slot. Warm replacement drives to room temperature before installation. For example, let a drive sit overnight before installing it in an array. Do not leave drive slots empty. Each drive slot in an array must contain a drive assembly or a blank carrier. Operating an array with an empty slot will void your warranty and support contract. Do not remove a functioning drive (other than a spare) from an array. If the drive is not a spare, the RAID set may become degraded. If you remove a spare, replace the drive as soon as possible. Do not remove a drive from its carrier. This action will void your warranty and support contract. Keep the shipping material. Return a failed drive to your array support provider in the packaging in which the replacement drive was shipped. Shipping drives in unauthorized packaging may void your warranty. Drive Installation Guidelines and Restrictions Replace a failed drive as soon as possible to provide the highest availability. Install only drives of the same type, speed, and spin rate in an array. Make sure the drive is oriented in the correct position for the array model. See Front-Panel Features and Indicators on page 3. You can use drives of different capacities in the same array. However, the smallest drive in the array will determine how much space can be used on each drive. For example, if the smallest drive is 400GB, only 400GB of space will be available for use on each drive. Make sure to insert a drive fully in the chassis before pushing in the handle. When correctly installed, a drive will be flush with the front of the array. If the drive is protruding from the array, reinstall the drive. After installation, make sure the drive power LED is green or flashing green. See Identifying Failed Drives on page 7. 9

16 Maintaining Drives There is a two-minute delay between the time you insert a drive and the time the drive is automatically configured into a RAID set. This time interval allows multiple drives to be simultaneously configured in an array, which is more efficient than installing a single drive, configuring it, and then repeating the process. For example, when you install a drive, the timer starts. If no other drives are installed, the drive is configured after a delay of two minutes. If you install another drive before two minutes have elapsed, the timer is restarted. If you install a drive during RAID reconstruction or verification, the new drive will not be configured until the operation completes. Removing a 2.5-inch Drive 1. Remove the bezel. See Removing the Bezel on page Press the release button (callout 1 in Figure 8). The drive latch opens and the drive emerges partway from the array (callout 2). 3. Pull the drive out by the handle until it is free of the drive bay (callout 3). 10

17 Maintaining Drives Figure 8 Removing a 2.5-Inch Drive Installing a 2.5-inch Drive The 2.5-inch drives are installed vertically, with the drive release latch on the top and the drive label on the bottom. 1. Wear electrostatic protection when handling a drive. See Protecting Hardware on page Open the drive release latch. 3. Hold the drive by the carrier and slide the drive most of the way into a slot (callout 1 in Figure 9). 11

18 Maintaining Drives 4. Push the drive completely into the slot (callout 2). The drive handle will begin to close onto the drive (callout 3). 5. Push in the handle until you hear a click (callout 4). Figure 9 Installing a 2.5-inch Drive Verify that the new drive is operational by examining the LEDs on the front panel, as described in Interpreting Drive LEDs on page 7. In addition, examine the GUI Member Disks window and the CLI member select show disks command output. Removing a 3.5-inch Drive 1. Remove the bezel. See Removing the Bezel on page 2. 12

19 Maintaining Drives 2. Press the release button (callout 1 in Figure 10). The drive latch opens and the drive emerges partway from the array (callout 2). 3. Pull the drive out by the handle until it is free of the drive bay (callout 3). Figure 10 Removing a 3.5-Inch Drive Installing a 3.5-inch Drive The 3.5-inch drives are installed horizontally, with the drive release latch to the left and the drive label to the right. 1. Wear electrostatic protection when handling a drive. See Protecting Hardware on page Open the drive release latch. 3. Hold the drive by the carrier and slide the drive most of the way into a slot (callout 1 in Figure 11). 13

20 Maintaining Drives 4. Push the drive completely into the slot (callout 2). The drive handle will begin to close onto the drive (callout 3). 5. Push in the handle until you hear a click (callout 4). Figure 11 Installing a 3.5-inch Drive Verify that the new drive is operational by examining the LEDs on the front panel, as described in Interpreting Drive LEDs on page 7. In addition, examine the GUI Member Disks window and the CLI member select show disks command output. Installing a Drive Blank 1. Remove the bezel. See Removing the Bezel on page Insert the drive blank into the drive bay until the blank is fully seated. 3. Attach the bezel. 14

21 Maintaining Drives Removing a Drive Blank Warning: To maintain proper system cooling, all empty drive bays must have drive blanks installed. 1. Remove the bezel. See Removing the Bezel on page Press the release tab and slide the drive blank out until it is free of the drive bay. See Figure 12 or Figure 13. Figure 12 Removing and Installing a 3.5-Inch Hard-Drive Blank Figure 13 Removing and Installing a 2.5-Inch Hard-Drive Blank Item Description 1 Drive blank 2 Release tab 15

22 Maintaining Drives 16

23 3 Maintaining Control Modules Different PS Series array models contain different control module types. The combination of chassis type, control module pair, and drives determines the PS Series array model number. The control modules in a PS Series array contain the PS Series firmware which provides the Group Manager GUI, the Command Line Reference, and all the array and storage management functions and features. Ideally, an array has two control modules (which must be of the same type) to avoid a single point of failure for the array. A PS4100 array includes one or two hot-swappable Type 12 control modules. One functioning control module is required for array operation. You access control modules from the rear of the array. Control Module Features The Type 12 control module includes: Two 1G Ethernet ports, labeled Ethernet 0 and Ethernet 1 (each Ethernet port has two LEDs indicating status and activity). One 10Mb/100Mbps port, labeled MANAGEMENT (for use only if you configure a management network). The management port has two LEDs to indicate status and activity. A column of LEDs labeled PWR (power), ERR (error condition) and ACT (activity) that indicate the status of the control module. A recessed button labeled STANDBY ON/OFF that allows you to quickly shut down the array in certain circumstances (see About the Standby On/Off Button on page 21 for more information). One serial port (for use if there is no network access to the array). A field-replaceable microsd card containing the PS Series firmware. A release button and latch to release the control module from the array for replacement. The release lever has a switch that detects activation and prompts the array to save data to non-volatile storage, thereby protecting your data. Do not mix control module types in an array. Always make sure both control modules are the same type and color. See the latest PS Series Release Notes for information about other supported control modules. About Control Module Configurations While an array can run using only one control module, it is not recommended as this creates a single point of failure. If the control module fails and there is no other to take over, all access to your volumes stops until you replace it. Only one control module is active (serving network traffic) at one time. The secondary (redundant) control module mirrors cache data from the active control module. If the active control module fails, the secondary will take over network operations. 17

24 Maintaining Control Modules Single Controller Configuration A single control module is a single point of failure. If the control module fails, the entire array (and all the volumes on it) becomes unavailable. Dell strongly recommends buying an array with two control modules, or installing a second control module in a single-controller array. In an array with a single control module, the module must be in slot CM0. Caution: For proper array cooling and airflow requirements, there must be a blank filler in the empty control module slot. Dual Controller Configuration A dual control module configuration eliminates a single point of failure in the array. If the active control module fails, the secondary control module takes over immediately with no interruption of service. This gives you time to replace the failed control module while your volumes and data remain accessible. Interpreting Control Module LEDs Control modules have the following LEDs: The Ethernet ports and the Management port each have two green LEDs that indicate the port's status and activity. Below the release latch is a column of three LEDs that indicate the status of the entire control module. Figure 14 Control Module LEDs 18

25 Maintaining Control Modules Table 5 Ethernet and Management Port LED Descriptions LED Location State Description Left Off No power or not connected to network. On Connected to network. Right Off No power, not transmitting, or not receiving. On Transmitting or receiving. Table 6 Control Module Status LED Descriptions LED Name State Description PWR Off No power. On (steady green) Power/OK. ACT Off No power, secondary control module is not synchronized with active control module, or error condition. Steady green Active control module (serving network I/O). Steady amber Secondary control module. Cache is synchronized with active control module. ERR Off Normal operation or no power. Steady red Array is starting up or error condition. Blinking red Array is entering power standby mode because the Standby On/ Off button was pressed. Identifying Control Module Failures You can identify a failure in a control module by: LEDs on the control module itself. See Interpreting Control Module LEDs on page 18. Messages on the console, in the event log, or in the Group Manager GUI Alarms panel. Group Manager GUI and CLI output. The Member Controllers window or the member select show controllers command output shows the control module status not installed. When viewed from the rear of the array, CM0 is on the top, and CM1 is on the bottom. See Front-Panel Features and Indicators on page 3. If a control module fails, contact your PS Series support provider for a replacement. Understanding Failover Behavior In a dual control module array, only one control module is active (serving network traffic) at one time. Each control module includes a cache-to-flash module for storing recently-used data. For redundancy, the cache on the secondary control module mirrors the data that is stored in the cache on the active control module. The active control module can use network interfaces on the secondary control module if there is a cable connected from the corresponding port on the secondary control module to a network switch. Therefore, you should connect cables to all the network interface ports on each control module to make sure that both control modules can access an interface. 19

26 Maintaining Control Modules Note: The management ports on the control modules do not fail over if one control module fails. Therefore, if you are using a dedicated management network, make sure the management ports on both control modules are connected to the management network. A PS series array provides two types of network failure protection: Network connection failover. If multiple network interfaces are configured and one network interface fails, iscsi initiators that were connected to the failed interface can reconnect to the group IP address and be redirected to a functioning interface. For example, in a single control module array, if Ethernet 0 and Ethernet 1 are connected to a network, and Ethernet 0 fails, initiators that were connected to Ethernet 0 can be redirected to Ethernet 1. Control module failover. In a dual control module array, if the active control module fails, the secondary automatically takes over and becomes active. If a cable is connected to the port on the newly active control module, network I/O can continue through that interface. Control module failover is transparent to applications, but iscsi initiators must reconnect to the group IP address. Maintaining Control Module Firmware A Type 12 control module has a microsd card running the array firmware. You should run the latest firmware version to take advantage of new product features and enhancements. Caution: In a dual control module array, both control modules must be running the same firmware version; otherwise, only one control module will be functional. When you update the array firmware, both control modules are updated to the same firmware version. Group members should run the same firmware version; otherwise, only the functionality common to all versions will be available in the group. See the PS Series Release Notes for information about mixedfirmware groups. If you are adding a second control module, upgrading a control module, or replacing a failed microsd card, contact your PS Series support provider for a replacement. Inform your provider of the current PS Series firmware version on your system. If you are replacing a failed control module, remove the microsd card from the failed control module and install it in the replacement control module. This will make sure that you keep the correct firmware. To display the firmware version running on an array, examine the GUI Member Controllers window or use the following CLI command: member select show controllers If the firmware on a microsd card does not match the firmware running on an array, do not install it. Instead, contact your array support provider. Control Module Handling Requirements Follow these control module handling requirements: Protect control modules from electrostatic discharge. Always wear an electrostatic wrist strap when handling a control module, as described in Protecting Hardware on page 1. Do not remove a control module from an array while the control modules are synchronizing. When synchronization completes, a console message will appear. Also, the ACT LED on the secondary control module will be orange. 20

27 Maintaining Control Modules Do not leave a control module slot empty. In an array with one control module, always attach a blank face plate to the empty control module slot. Store control modules properly. Store a control module in its original packaging or in an anti-static bag or place the control module on a surface protected from electrostatic discharge. About the Standby On/Off Button The Type 12 control module has a small, recessed button labeled Standby ON/OFF (see Figure 15). The button is recessed to prevent accidental activation. Figure 15 Standby Button Location Enabling the Standby Feature To use the standby button, a group administrator must enable the feature in the Group Manager GUI or CLI. Enabling the use of the button applies group-wide; that is, it allows you to press the button to shut down any member (array) that has the button (currently, PS4100 and PS6100 array models only). You do not need to enable use of the button on each member separately. Note: Only a user with group administrator privileges can enable the standby feature on the group. However, anyone can press the button, and the group cannot determine who put the array into standby on/ off mode. Therefore, group administrators should consider their environment's security concerns before enabling this feature. Using the Standby Button After the feature is enabled group-wide, you can use the Standby On/Off button on either control module of any applicable member to shut down the array quickly without using the Group Manager GUI or CLI. You must press in and hold the Standby On/Off button for at least two (2) seconds to shut down the member to the standby state. (To fully shut down the array, turn off the switches on the power supply and cooling modules.) To turn the member back on, press and hold the Standby On/Off button again (if the power supply switches are turned on). Important Considerations Use this button only in when you must shut down a member fast, in situations where you do not have access to the Group Manager GUI or CLI. Caution: In standby mode, any volumes that use space on that member or that are bound to that member become unavailable! 21

28 Maintaining Control Modules All operations on the member are suspended, there is no I/O activity to or from the member, and the member's firmware is not running. Use the Standby On/Off button only when you need to quickly shut down an array and you may not have access to the GUI or CLI; for example, if you discover a problem in your lab environment, such as high temperature or a water leak that may damage the array, that requires you to shut down the array as soon as possible. Caution: Do not shut down the array (with the standby on/off button or by any other method) before replacing a failed control module! If the member is shut down and a controle module is removed, the array automatically returns to full-power mode. Using the Standby On/Off button on one member does not affect any other group members. You must press the button on each member that has it. Group members that do not have the button remain online; to shut them down, you must use the GUI or CLI. Replacing a Control Module If a control module fails, remove it and replace it with a functioning control module. Do not remove a failed control module until you are ready to replace it. You may need to temporarily remove a control module to replace its microsd card. Note: For proper cooling, do not leave a control module slot empty. If an array will operate for a long time with only one control module, you must install a blank in the empty slot. You can order a control module blank from your PS Series array service provider. You can partially or completely remove a control module without shutting down the array if the remaining control module has at least one connected and functioning network interface. However, if you remove the active control module (the LED labeled ACT will be green), there will be a short interruption as failover to the secondary control module occurs. Otherwise, if possible, cleanly shut down the array before removing the module, as described in Shutting Down and Restarting an Array on page 5. Caution: Do not remove a control module from an array while the control modules are still synchronizing. A message will appear on the console when synchronization completes. The ACT LED on the secondary control module will be orange when synchronization completes. Removing a Control Module Before removing a control module: Attach an electrostatic wrist strap, as described in Protecting Hardware on page 1. Disconnect any serial or network cables attached to the control module. Optionally, re-attach the network cables to the other control module to provide uninterrupted data access. To remove a control module: 1. Push down on the orange release button. See Figure

29 Maintaining Control Modules 2. Holding the orange button down, swing the black release latch towards you. This starts to eject the control module from the array. Figure 16 Removing a Control Module 3. Place the control module on a flat surface where it will be protected from electrostatic charge. To avoid damage, do not place anything on top of the control module. 4. If you are replacing a failed control module, remove the microsd card from the failed control module and install it in the replacement control module. This will make sure that the new control module is running the correct firmware. See Replacing the MicroSD Card on page 24. Caution: Do not operate an array with an empty control module slot. Return the failed control module in the packaging in which the replacement module was shipped. Contact your PS Series support provider for information about returning hardware. Installing a Control Module You can install a control module without shutting down the array. Caution: Do not mix control module types in an array. Control modules are installed horizontally in the array, with the Ethernet ports on the left and the serial port on the right. See Figure 17. Figure 17 Correct Control Module Orientation Facing the rear of the array, the upper control module is CM0 and the lower control module is CM1. To install a control module: 1. Attach an electrostatic wrist strap or a similar protective device. See Protecting Hardware on page 1. 23

30 Maintaining Control Modules 2. Push down on the orange release tab and swing the black lever out. 3. Slide the control module into the chassis until you feel resistance. Figure 18 Installing a Control Module 4. Rotate the black lever inward, which pushes the control module completely into the slot. The latch on the lever will snap into place. 5. Reconnect the network cables. 6. If the array was shut down, turn on power to the array. 7. Make sure the control module is operational. See Interpreting Control Module LEDs on page 18. When connected, the control module cache-to-flash module receives full charge. If it cannot be charged, its status is reported as BAD in the Group Manager GUI. You must remove the control module and replace it with another one. If two control modules are installed but only one is shown in the GUI or CLI, the control module may not be properly installed. Reinstall the control module. If both control modules still are not shown in the GUI or CLI, they may not be running the same firmware. Contact your array support provider. Replacing the MicroSD Card Each control module includes a microsd card that contains the PS Series firmware. If a control module fails, remove the microsd card from the failed control module and install the card in the replacement control module. This will make sure that the new control module is running the same firmware as the other control module in the array. You can remove a control module without shutting down the array if the remaining control module has at least one connected and functioning network interface. If you remove the active control module (the LED labeled ACT will be green), there will be a short interruption as failover to the secondary control module occurs. When you remove the control module, place it on a surface that is protected from electrostatic discharge. 24

31 Maintaining Control Modules Before replacing a microsd card: Attach an electrostatic wrist strap, as described in Protecting Hardware on page 1. See Replacing a Control Module on page 22 for instructions on removing a control module. Removing the MicroSD Card Caution: To reduce the risk of losing or damaging the microsd card, do not remove it until you are ready to install it in the replacement control module. 1. Firmly push the card into its housing to release the spring mechanism (Figure 19). The microsd card will be partially ejected from the housing. Figure 19 Ejecting the MicroSD Card 2. Gently pull the card straight out of the housing. 3. Place the microsd card on a flat surface where it will be protected from electrostatic charge. 25

32 Maintaining Control Modules Inserting the MicroSD Card 1. Align the replacement microsd card so the arrow on the card points towards the housing (Figure 20). 2. Firmly press the card into the housing until it clicks into place. Make sure you cannot pull it out. Figure 20 Inserting the MicroSD Card 3. Install the control module in the array. See Installing a Control Module on page Make sure the control module is operational. See Interpreting Control Module LEDs on page 18. Advanced Networking Options In addition to connecting all the Ethernet ports on both control modules to network switches, you can also optionally connect the Management port to a separate network switch. Configuring a management port enables you to separate management traffic (creating and managing the group, members, volumes, replication, and so on) from the iscsi data traffic (I/O between applications and volumes, and between replication partners). 26

33 Maintaining Control Modules Configuring the Management Port Configuring the 10/100Mbps management port involves hardware steps and software steps. The management port is restricted to group management traffic only; it will not carry iscsi I/O. Note: This is considered an advanced configuration, available if your environment requires this level of security. Hardware Steps 1. Make sure your network environment can support a dedicated management network, with a subnet that is separate from the subnets for iscsi traffic. 2. On both control modules, connect the port labeled MANAGEMENT to the management network. Software Steps See the Group Administration guide for the procedure to configure the management network in the Group Manager GUI. 27

34 Maintaining Control Modules 28

35 4 Maintaining Power Supply and Cooling Modules The array can support two hot-swappable power supply and cooling modules. The array can operate only temporarily with one module, but both modules must be present for long-term cooling of the array. About AC Power Supplies The PS Series array receives A/C power from two power supply and cooling modules (PSUs). The fans that keep the array cool are integrated into the power supply modules and cannot be replaced separately. If a fan fails, you must replace the entire power supply module. The PS4100 has two 700 Watt PSUs. Each 700W power supply has two cooling fans. Power Supply LEDs The power supply and cooling modules have LEDs that indicate their status. See Figure 21 and Table 7. Figure W Power Supply LEDs 29

36 Maintaining Power Supply and Cooling Modules Table 7 Power Supply LED Descriptions Item LED Color State 1 DC power Green ON Normal operation. Power supply is connected to AC power and the power switch is on. The power supply module is supplying DC power to the array. OFF when any of these is true: The power switch is off The power supply is not connected to AC power There is a fault condition For a list of warning or critical level faults, see the Group Administration manual. 2 Fault Amber On Fault detected. OFF OK. Blinks briefly when power is first turned on to the power supply module. For a list of warning or critical level faults, see the Group Administration manual. 3 AC power Green ON Power supply module is connected to a source of AC power whether or not the power switch is on. OFF Power supply module is completely disconnected from any source of AC power. Under normal conditions, the AC and DC power LEDs will be lit at the same time. Removing a Power Supply and Cooling Module If a power supply and cooling module fails, you must replace the module as soon as possible, although an array can operate with only one working module. For proper array cooling, do not remove a failed module until you are ready to replace it. Caution Wear electrostatic protection when handling a power supply and cooling module. See Protecting Hardware on page 1. To remove a power supply and cooling module: 1. Turn off the power switches on the power supply and cooling module. 2. Disengage the hook-and-loop fastener from around the power cable. 3. Remove the power cable. You can remove a power supply and cooling module from an array without affecting array operation if the second module is installed and functioning. However, to maintain proper air flow in the array, a power and cooling module must be replaced within five (5) minutes of removing it. Otherwise, if possible, cleanly shut down the array before removing the module, as described in Shutting Down and Restarting an Array on page With your right hand, hold the handle and push the orange release latch to the right with your thumb. 30

37 Maintaining Power Supply and Cooling Modules 5. Pull the module from the slot. See Figure 22. Caution: The module is heavy; support it with two hands. Figure 22 Removing a Power Supply and Cooling Module Installing a Power Supply and Cooling Module 1. Hold the power supply module so that the orange release latch is on the upper left. 2. Slide the power supply and cooling module into the chassis until it is fully seated and the release latch clicks into place. See Figure 23. Note: Before the power cable is connected, the fans start spinning, powered by the other power supply module. 31

38 Maintaining Power Supply and Cooling Modules Figure 23 Inserting a Power Supply and Cooling Module 3. Make sure the power switch is in the OFF position. 4. Connect the power cable to the power supply and cooling module and plug the cable into a power outlet. Note: The AC LED lights up when the AC power cable is connected, even if the switches on the power supply are off. 5. Secure the power cable using the hook-and-loop fastener strap. See Figure

39 Maintaining Power Supply and Cooling Modules Figure 24 : Securing the Power Cable 6. Turn on the switches on the power supply and cooling module. 33

40 Maintaining Power Supply and Cooling Modules 34

41 5 Troubleshooting Your Array Safety First For You and Your array Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. Obtaining Technical Support and Customer Service Dell s support service is available to answer your questions about PS Series SAN arrays. If you have an Express Service Code, have it ready when you call. The code helps Dell's automated-support telephone system direct your call more efficiently. Contacting Dell Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services might not be available in your area. For customers in the United States, call Note: If you do not have access to an Internet connection, contact information is printed on your invoice, packing slip, bill, or Dell product catalog. Use the following procedure to contact Dell for sales, technical support, or customer service issues: 1. Visit support.dell.com. 2. Verify your country or region in the Choose A Country/Region drop-down menu at the bottom of the window. 3. Click Contact Us on the left side of the window. 4. Select the appropriate service or support link based on your need. 5. Choose the method of contacting Dell that is convenient for you. Determining Service Tag Information Each array has a service tag with a number. You may need to provide this information to customer support when you contact us. The service tag label is visible on the front of the PS4100, on the right bezel latch block. 35

42 Troubleshooting Your Array Obtaining Component Diagnostics You can collect diagnostic information for one or more members of a PS Series group through the Group Manager GUI or the CLI. See the Group Administration guide or the CLI Reference for more information. Troubleshooting Array Startup Failure If your system halts during startup, check if: The array fault LEDs are lit. See Front-Panel Features and Indicators on page 3. There is a constant scraping or grinding sound when you access the hard drive. See Obtaining Technical Support and Customer Service on page 35. Troubleshooting Loss of Communication For information about troubleshooting loss of communication, see Network Requirements and Recommendations in the Installation Guide for your array. Troubleshooting Array Connections 1. Verify that the control module port link status LED and the control module status LED are solid green for each port that is connected to a cable. If the LEDs are not solid green, see Control Module Features on page Make sure that all the cables are attached correctly. If the problem is not resolved, see Obtaining Technical Support and Customer Service on page 35. Troubleshooting External Connections Verify that the cables are connected to the correct Ethernet and, if applicable, Management ports before troubleshooting any external devices. For the location of the back-panel connectors on your array, see Back-Panel Features and Indicators on page 4. Make sure that the power cables are securely attached to the power supply modules on your array. Troubleshooting Power Supply and Cooling Modules 1. Locate the faulty power supply and determine the status of the LEDs. If the AC power LED is not lit, check the power cord and power source into which the power supply is plugged. Connect another device to the power source to verify if it is working. Connect the cable to a different power source. 36

43 Troubleshooting Your Array Replace the power cable. If the problem is not resolved, or if the power supply s fault indicator is lit, see Obtaining Technical Support and Customer Service on page 35. Power supply and cooling modules are hot-swappable. The array can operate on a single power supply; however both modules must be installed to ensure proper cooling. A single power supply and cooling module can be removed from a powered-on array for a maximum of five minutes. Beyond that time, the array may automatically shut down to prevent damage. 2. Reseat the power supply by removing and reinstalling it. See Removing a Power Supply and Cooling Module on page 30. Note: After installing a power supply, allow several seconds for the array to recognize the power supply and to determine if it is working properly. If the problem is not resolved, see Obtaining Technical Support and Customer Service on page 35. Troubleshooting Array Cooling Problems Check for and correct any of the following situations: Empty drive bays (no drive or drive blank). Ambient temperature is too high. See the Technical Specifications for the array in the Installation and Setup Guide. External airflow is obstructed. The power supply and cooling module is removed or has failed. See Troubleshooting Power Supply and Cooling Modules on page 36. If the problem is not resolved, see Obtaining Technical Support and Customer Service on page 35. Troubleshooting Control Modules 1. Remove the control module and verify that the pins on the backplane and control module are not bent. See Replacing a Control Module on page Reinstall the control module and wait for 30 seconds. See Replacing a Control Module on page Check the control module status LEDs. See Interpreting Control Module LEDs on page 18 for more information. 4. If control module status LED is blinking amber (5 times per sequence), update the firmware to the latest supported firmware on both the control module. For more information about downloading the latest firmware, see the PS Series Release Notes and the document Updating PS Series Storage Array Firmware, available on the customer support site. 5. If the link status LEDs are not green: a. Reseat the cables on the control modules and the switches. 37

44 Troubleshooting Your Array b. Check the link status LED. If the link status LED is not green, proceed to the next step. c. Replace the cables. If the problem is not resolved, see Obtaining Technical Support and Customer Service on page 35. Troubleshooting Hard Drives Check the hard drive indicators before removing the faulty drive from the array. 1. Remove the drive from the array. See Identifying Failed Drives on page Check the drive to make sure that the connectors are not damaged. 3. Reinstall the drive. 4. Verify that the control module port link status LED and the control module status LED are solid green for each port that is connected to a cable. If the LEDs are not solid green, see Interpreting Control Module LEDs on page 18. If the problem is not resolved, see Obtaining Technical Support and Customer Service on page

45 Index array control module restriction...23 control modules...17 cooling...29 fans...29 firmware...20 LEDs...7, 18 power supplies...29 shutdown procedure...5 bezel installing...2 removing...2 control modules batteries...17 checking proper installation...24 failover behavior...19 failure indications...19 features...17 firmware requirements...20 firmware version...20 handling requirements...20 installing in array...23 LEDs...18 locating...19 removing from array restriction on mixing restrictions supported disk type synchronizing... 20, 22 types verifying operational status cooling removing disks failure behavior... 8 failure indications... 7 handling requirements... 9 LEDs... 7 locating... 7 protecting... 9 verifying operational status... 12, 14 electrostatic discharge, avoiding... 1 electrostatic wrist strap, using... 1 failover control module network connection failure indications control modules

46 Index disks...7 fans removing...30 firmware identifying version...20 requirements...20 front panel features...3 identifying the firmware version...20 indicators power...3 installing drive blank...14 front bezel...2 power supply/cooling fan module 31 LEDs control module...18 disks...7 network interfaces...18 microsd card firmware requirements...20 inserting...26 removing...25 replacing...20 network failure protection...20 network interfaces LEDs power indicators... 3 power supplies removing PS Series array protecting from discharge... 1 recommended tools... 1 removing 3.5-inch drive... 10, 12 drive blank requirements control modules cooling disks... 9 firmware power safety shutting down an array... 5 status control modules troubleshooting connections cooling problems external connections hard drives

PS6500 Storage Arrays Hardware Maintenance

PS6500 Storage Arrays Hardware Maintenance PS6500 Storage Arrays Hardware Maintenance 110-0118-EN-R2 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks and registered

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

Dell PowerVault MD3400 and MD3420 Storage Arrays Owner's Manual

Dell PowerVault MD3400 and MD3420 Storage Arrays Owner's Manual Dell PowerVault MD3400 and MD3420 Storage Arrays Owner's Manual Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

HP SATA/SAS hard drive and Solid State Drive installation

HP SATA/SAS hard drive and Solid State Drive installation HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal

More information

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage

More information

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

3.5 Dual Bay USB 3.0 RAID HDD Enclosure 3.5 Dual Bay USB 3.0 RAID HDD Enclosure User Manual August 11, 2011 v1.1 MFG Part # MT2U3-MP BARCODE Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

HP 22-in-1 Media Card Reader

HP 22-in-1 Media Card Reader HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

UPGRADING AND SERVICING GUIDE

UPGRADING AND SERVICING GUIDE UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing

More information

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service This field replacement guide provides instructions for replacing the two AC power supplies in an EX4500 Ethernet

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual DE1600 DSA E-Series iscsi Disk Arrays en Installation Manual DE1600 DSA E-Series iscsi Disk Arrays Table of Contents en 3 Table of Contents 1 Safety Precautions 4 1.1 Warning Notices 4 1.2 Caution Notices

More information

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0 4-Bay RAID Storage Enclosure User Manual January 16, 2009 - v1.0 EN Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC Requirements... 1 1.1.2 Mac Requirements... 1 1.1.3 Supported

More information

Service Guide. Gateway M275

Service Guide. Gateway M275 Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying

More information

Serial ATA to Serial ATA

Serial ATA to Serial ATA Serial ATA to Serial ATA Model: MRK-300ST-BK Aluminum Mobile Rack 3-1 3-1 Introduction... 3-3 Mobile Rack Features... 3-3 Unpacking Your Mobile Rack... 3-4 IDE Basics... 3-4 3-2 Hardware Installation...

More information

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009 Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,

More information

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module May 2011 51358-00, Rev. A ST2501 M2 Drive Module Initial Setup Guide May 2011 Revision History Version and Date 51358-00,

More information

Infinity C Reference Guide

Infinity C Reference Guide 1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...

More information

Small form factor bay converter and hard drive installation

Small form factor bay converter and hard drive installation Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold

More information

Inspiron 13. Service Manual. 7000 Series. Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001

Inspiron 13. Service Manual. 7000 Series. Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001 Inspiron 13 7000 Series Service Manual Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps

More information

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...

More information

CM500 High Speed Cable Modem User Manual

CM500 High Speed Cable Modem User Manual User Manual February 2015 202-11472-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label

More information

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and

More information

Contents. Installing the upgrade memory kit in the G450 and G430 Media Gateway May 2014 1

Contents. Installing the upgrade memory kit in the G450 and G430 Media Gateway May 2014 1 Contents Installing the upgrade memory kit in the G450 / G430 Media Gateway... 3 Equipment ordering... 3 Inserting or replacing a RAM card... 4 Inserting or replacing a RAM card in the G450... 4 Replacing

More information

Front Panel Board Cable Replacement Instructions

Front Panel Board Cable Replacement Instructions apple Mac Pro Front Panel Board Cable Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and void its warranty.

More information

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: 122211 PN: 883884-32L Rev.

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: 122211 PN: 883884-32L Rev. Installation Guide Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit Products: Z90DW, Z90SW, Z90D7, Z90S7 Issue: 122211 PN: 883884-32L Rev. A Copyright Notices 2011, Wyse Technology Inc. All rights reserved.

More information

Replacing the Gateway M320 Keyboard

Replacing the Gateway M320 Keyboard Replacing the Gateway M320 Keyboard This package includes a replacement keyboard for your Gateway M320 notebook and these printed instructions. Tools you need You need a small Phillips and a small flat-blade

More information

Inspiron 15. Service Manual. 3000 Series

Inspiron 15. Service Manual. 3000 Series Inspiron 15 3000 Series Service Manual Computer Model: Inspiron 15 3541/Inspiron 15 3542/Inspiron 15 3543 Regulatory Model: P40F Regulatory Type: P40F001/P40F002 Notes, Cautions, and Warnings NOTE: A NOTE

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel

More information

Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B

Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following

More information

How to Set Up Your NSM4000 Appliance

How to Set Up Your NSM4000 Appliance How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning

More information

DF-7506 1-to-2 SATA II RAID Box

DF-7506 1-to-2 SATA II RAID Box DF-7506 1-to-2 SATA II RAID Box Version 1.0 Table of Contents Chapter 1 Product Introduction...3 1.1 Features...3 1.1.1 Shipping Package Content...3 1.2 Front View...4 1.3 Rear View...6 1.4 Disk Drive

More information

CM400 High Speed Cable Modem User Manual

CM400 High Speed Cable Modem User Manual User Manual July 2015 202-11412-02 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of

More information

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives. User Manual August 18, 2011 - v1.0 www.akitio.

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives. User Manual August 18, 2011 - v1.0 www.akitio. Hydra Super-S LCM 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives User Manual August 18, 2011 - v1.0 www.akitio.com EN Hydra Super-S LCM Table of Contents Table of Contents 1 Introduction...

More information

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007 HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007 United States Copyright 2007 Hewlett-Packard Development Company L.P.. Legal Notices

More information

SGI InfiniteStorage NAS 50/100 Quick Start Guide 007-5621-001

SGI InfiniteStorage NAS 50/100 Quick Start Guide 007-5621-001 SGI InfiniteStorage NAS 50/100 Quick Start Guide 007-5621-001 COPYRIGHT 2010 SGI. All rights reserved; provided portions may be copyright in third parties, as indicated elsewhere herein. No permission

More information

Tyan Computer. Transport PX22. Service Engineer s Manual

Tyan Computer. Transport PX22. Service Engineer s Manual Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,

More information

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement MaxAttach NAS 4000 Series MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement DOCUMENT OVERVIEW Who Should Use This Instruction Set This MaxAttach NAS 4000 Series by Maxtor HDD Replacement Instruction

More information

ilan Ethernet Box for 9100 Installation Manual

ilan Ethernet Box for 9100 Installation Manual ilan Ethernet Box for 9100 Installation Manual 07103-00154 March 11, 2014 Corporate Headquarters: 21405 B Street Long Beach, MS 39560 Phone: (800) 259-6672 Fax: (228) 868-9445 Copyright Notice 2014 Triton.

More information

Cisco CWDM GBIC and CWDM SFP Installation Note

Cisco CWDM GBIC and CWDM SFP Installation Note Cisco CWDM GBIC and CWDM SFP Installation Note, Product Numbers: CWDM-GBIC-1470= CWDM-GBIC-1550= CWDM-SFP-1470= CWDM-SFP-1550= CWDM-GBIC-1490= CWDM-GBIC-1570= CWDM-SFP-1490= CWDM-SFP-1570= CWDM-GBIC-1510=

More information

HP ProLiant DL165 G7 Server. Installation Instructions

HP ProLiant DL165 G7 Server. Installation Instructions HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status

More information

UPS Network Interface. Quick InstallationGuide

UPS Network Interface. Quick InstallationGuide UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,

More information

Using RAID Admin and Disk Utility

Using RAID Admin and Disk Utility Using RAID Admin and Disk Utility Xserve RAID Includes instructions for creating RAID arrays and monitoring Xserve RAID systems K Apple Computer, Inc. 2003 Apple Computer, Inc. All rights reserved. Under

More information

ReadyNAS OS 6 Desktop Storage Systems

ReadyNAS OS 6 Desktop Storage Systems ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: ReadyNAS 102 ReadyNAS 104 ReadyNAS 312 ReadyNAS 314 ReadyNAS 316 ReadyNAS 516 ReadyNAS 716X EDA 500 October 2013 202-11206-04 350 East Plumeria

More information

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Replacement Instructions. Warning: During this procedure, keep small parts away from children. apple ibook G4 Memory Card Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Written

More information

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System

4x3.5 Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System 4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK

More information

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens clean the fan intake filter replace the projection lamp replace the batteries in the remote control use the Kensington lock feature

More information

FUSION R400 RAID USB 3.0

FUSION R400 RAID USB 3.0 FUSION R400 RAID USB 3.0 1U Rackmount 4-Drive Hardware RAID 5 SATA Storage System with USB 3.0 Interface User s Guide For Windows Contents 1 Fusion R400 RAID USB 3.0 Features 1 2 Drive Installation and

More information

HP Integrity rx2660 Server Installation Guide

HP Integrity rx2660 Server Installation Guide HP Integrity rx2660 Server Installation Guide HP Part Number: AB419-9000C Published: November 2007 Copyright 2007 Hewlett-Packard Development Company, L.P Legal Notices The information contained herein

More information

HP Advanced Wireless Docking Station. User Guide

HP Advanced Wireless Docking Station. User Guide HP Advanced Wireless Docking Station User Guide Copyright 2014, 2015 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Windows and Windows

More information

Dell Inspiron 660s Owner s Manual

Dell Inspiron 660s Owner s Manual Dell Inspiron 660s Owner s Manual Computer model: Inspiron 660s Regulatory model: D06S Regulatory type: D06S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you

More information

HP Optical Bay Hard Drive Bracket

HP Optical Bay Hard Drive Bracket HP Optical Bay Hard Drive Bracket Introduction This document describes how to install 8.89 cm (3.5 inch) hard drives in the HP optical bay hard drive bracket and install the bracket in the optical drive

More information

BX7000 Multi-Access Gateway Getting Started Guide

BX7000 Multi-Access Gateway Getting Started Guide BX7000 Multi-Access Gateway Getting Started Guide This guide provides instructions on connecting the Juniper Networks BX Series 7000 Multi-Access Gateway to a network. For more information, see the BX7000

More information

Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later

Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later This job aid describes the steps required to replace the hard drive on an Avaya S8710 Media Servers running Release 2.2

More information

BounceBack Server Solution Reference Guide

BounceBack Server Solution Reference Guide BounceBack Server Solution Reference Guide Contents Introduction... 2 System Requirements... 3 Initial Setup... 4 BounceBack Server Appliance Front View... 5 BounceBack Server Appliance Rear View... 6

More information

actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide

actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide Page 1 of 11 Introduction This poster describes how to install your ActiTape LTO half-height internal tape drives with SCSI and SAS interface.

More information

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: 092910 PN: 883884-13L Rev. A

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: 092910 PN: 883884-13L Rev. A Installation Guide Wyse C Class 2-GB RAM Upgrade Option Kit Issue: 092910 PN: 883884-13L Rev. A Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual and the software and firmware

More information

Replacing the Gateway M675 Keyboard

Replacing the Gateway M675 Keyboard Replacing the Gateway M675 Keyboard This package includes a replacement keyboard for your Gateway M675 notebook and these printed instructions. Tools you need You need a small Phillips screwdriver and

More information

2» 10» 18» 26» PD3 34 00 42»

2» 10» 18» 26» PD3 34 00 42» » STARDOM Safe Capsule Series User Manual... 2» STARDOM Safe Capsule Serie Bedienungsanleitung... 10» Série STARDOM Safe Capsule Manuel de l utilisateur... 18 26 PD3500 34» Manual de usuario de STARDOM

More information

McAfee Data Loss Prevention

McAfee Data Loss Prevention Hardware Guide Revision B McAfee Data Loss Prevention 1650, 3650, 4400, 5500 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage

More information

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device

More information

HP StoreVirtual 4630 Storage Maintenance Guide

HP StoreVirtual 4630 Storage Maintenance Guide HP StoreVirtual 4630 Storage Maintenance Guide Abstract This guide explains how to back up, restore, upgrade, and otherwise maintain the HP StoreVirtual 4630 storage system and solution components. The

More information

apple Service Source PowerBook G4 (DVI) Updated 4 December 2003 2003 Apple Computer, Inc. All rights reserved.

apple Service Source PowerBook G4 (DVI) Updated 4 December 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source PowerBook G4 (DVI) Updated 4 December 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Upgrades PowerBook G4 (DVI) 2003 Apple Computer, Inc. All rights reserved.

More information

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Replacement Instructions. Warning: During this procedure, keep small parts away from children. apple Power Mac G4 / Macintosh Server G4 ATA Hard Drive Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void

More information

Nighthawk AC1900 WiF Range Extender

Nighthawk AC1900 WiF Range Extender Nighthawk AC1900 WiF Range Extender Model EX7000 User Manual December 2014 202-11469-01 350 East Plumeria Drive San Jose, CA 95134 USA Nighthawk AC1900 WiF Range Extender Support Thank you for selecting

More information

Avid Unity MediaNetwork 5 System Maintenance

Avid Unity MediaNetwork 5 System Maintenance Avid Unity MediaNetwork 5 System Maintenance Avid Technology EMEA Enterprise Customer Success Page 1 of 21 Table of Contents Introduction... 2 Daily Maintenance Procedures... 3 Check the Monitor Tool for

More information

Chapter 10 Troubleshooting

Chapter 10 Troubleshooting Chapter 10 Troubleshooting This chapter explains how you can troubleshoot a specific problem, such as abnormal LED activity or no system power, when you power up the router. Topic Page Diagnosing Problems

More information

Quick Start Guide. RV0xx Series Routers

Quick Start Guide. RV0xx Series Routers Quick Start Guide RV0xx Series Routers RV042 Dual WAN VPN Router RV042G Gigabit Dual WAN VPN Router RV082 Dual WAN VPN Router RV016 Multi-WAN VPN Router Package Contents VPN Router Power Adapter (Cisco

More information

TS-x53 Pro, SS-x53 Pro, TS-651, TS-851, TS-x69 series (2/4/5/6/8-bay)

TS-x53 Pro, SS-x53 Pro, TS-651, TS-851, TS-x69 series (2/4/5/6/8-bay) Upgrade Memory on QNAP Turbo NAS (RAM Module Installation) Warning: The following instructions should only be performed by an authorized and trained technician. Strictly adhere to the instructions to install

More information

ProxySG 510/810 Series. Hard Disk Drive Installation

ProxySG 510/810 Series. Hard Disk Drive Installation Blue Coat 510/810 Series Disk Drive Installation Blue Coat ProxySG 510/810 Series Hard Disk Drive Installation Section A: Before You Begin About this Document This document describes how to replace disk

More information

Lenovo IdeaPad. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

Lenovo IdeaPad. User Guide. Read the safety notices and important tips in the included manuals before using your computer. Lenovo IdeaPad User Guide Read the safety notices and important tips in the included manuals before using your computer. Notes Before using the product, be sure to read Lenovo Safety and General Information

More information

Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17

Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,

More information

Monitoring the Switch

Monitoring the Switch CHAPTER6 Any problem in your switch can affect a large proportion of your users. Implementing a preventive approach to switch monitoring helps you to detect problems early and to avoid potential problems.

More information

Media Gateway Hardware

Media Gateway Hardware Media Gateway Hardware Getting to Know Your Media Gateway E-1 Media Gateway Front Panel E-1 Media Gateway Back Panel E-2 Media Player Front Panel E-2 Media Player Back Panel E-3 MP 2050 Front E-3 MP 2050

More information

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide HP LaserJet MFP Analog Fax Accessory 300 Fax Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written permission

More information

SERVICE GUIDE. Gateway Notebook

SERVICE GUIDE. Gateway Notebook SERVICE GUIDE Gateway Notebook Contents Replacing Gateway Notebook Components...................................1 Identifying the notebook model......................................... 2 Identifying

More information

N600 Wireless Dual Band Gigabit Router WNDR3700v2 Setup Manual

N600 Wireless Dual Band Gigabit Router WNDR3700v2 Setup Manual N600 Wireless Dual Band Gigabit Router WNDR3700v2 Setup Manual 2010 by NETGEAR, Inc. All rights reserved. NETGEAR, Inc. 350 E. Plumeria Drive San Jose, CA 95134 USA October 2010 208-10737-01 v1.0 Trademarks

More information

PA500II Enterprise Mobile Computer

PA500II Enterprise Mobile Computer PA500II Enterprise Mobile Computer - PA500II - Quick Reference Guide 400891G Version 1.0 PA500II Product Introduction & Accessory Kit After opening the box, ensure the following accessories for the PA500II

More information

110244-003. PrintPAD CN3/4/3e/4e. User Guide

110244-003. PrintPAD CN3/4/3e/4e. User Guide 110244-003 PrintPAD CN3/4/3e/4e User Guide TABLE OF CONTENTS PrintPAD CN3/4 & PrintPAD CN3e/4e Printer Views...1 Open View...1 Closed View...1 Using Batteries: General Guidelines...1 Installing and/or

More information

Dial Backup Module (DBM) Two standoff posts, four washers, and four Phillips-head screws 14 RJ49C ISDN-U cable Warranty card

Dial Backup Module (DBM) Two standoff posts, four washers, and four Phillips-head screws 14 RJ49C ISDN-U cable Warranty card TM ISDN BRI Dial Backup Module (DBM) Installation Instructions Document Number 9000-A2-GN19-30 Feature Number 9098-F1-870 February 1998 Before You Begin Make sure you have: Ordered ISDN service, and it

More information

SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL

SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL CORPORATE VERSION FEBRUARY 2007 TABLE OF CONTENTS Welcome... 3 Getting Started... 3 Equipment Setup... 3 Battery Installation... 4 About the Stylus... 5 Aligning

More information

Chapter 1 Installing the Gateway

Chapter 1 Installing the Gateway Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information

More information

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, 2009 - v1.3

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, 2009 - v1.3 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, 2009 - v1.3 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM

More information

Lenovo Miix 2 8. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

Lenovo Miix 2 8. User Guide. Read the safety notices and important tips in the included manuals before using your computer. Lenovo Miix 2 8 User Guide Read the safety notices and important tips in the included manuals before using your computer. Notes Before using the product, be sure to read Lenovo Safety and General Information

More information

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.

More information

Wireless Router Setup Manual

Wireless Router Setup Manual Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

N300 WiFi Range Extender WN2000RPT User Manual

N300 WiFi Range Extender WN2000RPT User Manual N300 WiFi Range Extender WN2000RPT User Manual December 2013 202-11333-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device,

More information

HP ProLiant DL380 G5 High Availability Storage Server

HP ProLiant DL380 G5 High Availability Storage Server HP ProLiant DL380 G5 High Availability Storage Server installation instructions *5697-7748* Part number: 5697 7748 First edition: November 2008 Legal and notice information Copyright 1999, 2008 Hewlett-Packard

More information

Frontier DSL SelfConnect Guide

Frontier DSL SelfConnect Guide Frontier DSL SelfConnect Guide Frontier DSL Self-Installation Guide Table of Contents Getting Started...2 Customer and Computer Requirements...2...3 STEP 1: Install Microfilters...3 STEP 2: Install Your

More information

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business Quick Start Guide Cisco Small Business RV 120W Wireless-N VPN Firewall Package Contents Wireless-N VPN Firewall Ethernet Cable Power Adapter Quick Start Guide Documentation and Software on CD-ROM Welcome

More information

LACIE 8BIG RACK THUNDERBOLT 2 USER MANUAL

LACIE 8BIG RACK THUNDERBOLT 2 USER MANUAL LACIE 8BIG RACK THUNDERBOLT 2 USER MANUAL CLICK HERE TO ACCESS AN UP-TO-DATE ONLINE VERSION of this document. You will find the most recent content as well as expandable illustrations, easier navigation,

More information

AC1200 WiFi Range Extender

AC1200 WiFi Range Extender Model EX6200 User Manual February 2014 202-11298-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number

More information

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD

More information