1 RTU-EN01 Modbus TCP Remote I/O Communication Module Operation Manual DVP
2
3 Introduction This operation manual only provides introductory information on electrical specification, installation and wiring. RTU-EN01 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may occur. DO NOT touch any terminal when the power is switched on. Please read this manual carefully and follow the instructions to avoid damage on the product or harm on staff. Table of Content 1 INTRODUCTION Features Specifications PRODUCT PROFILE & OUTLINE Dimension Product Profile LED Indicators RUN/STOP Switch RJ-45 PIN Definition RS-232 PIN Definition RS-485 PIN Definition INSTALLATION & WIRING Connecting RTU-EN01 to DVP Slim Series Digital Input/Output Module Installing RTU-EN01 and DVP Slim Series Digital Input/Output Module onto DIN Rail How to Connect RTU-EN01 to Network WORD DEVICES & BIT DEVICES IN RTU-EN Basic Registers (BR) Explanations on BR External Input Contacts (RX) External Output Contacts (RY) Control Register for Extension Modules (RCR) Word Devices & Bit Devices for Timers (T) Word Devices & Bit Devices for Counters (C) Bit Devices for Real-Time Clock (R) MODBUS COMMUNICATION Function Codes Supported Exception Codes Supported Device Type & Device Address...16 DVP-PLC Operation Manual 1
4 6 SETTING UP SOFTWARE Setting up Communications & Searching for Communication Modules in DCISoft Recording IP Address Basic Settings Network Settings Setting up Time Server IP Filter Smart PLC Setting: IF-THEN Smart PLC Setting: Timer Smart PLC Setting Counter Smart PLC Setting RTC Analog Input/Output Modules I/O Monitoring Table Setting up Gateway Virtual COM Security Setting Returning to Default Settings Web Function APPLICATION EXAMPLES DCISOFT Smart PLC: IF-THEN Smart PLC: Timer Smart PLC: Counter Smart PLC: RTC Virtual COM Microsoft and Windows Internet Explorer are the registered trade mark or trade mark of Microsoft Corporation in the United States and other countries. Java is the registered trade mark or trade mark of Sun Microsystems, Inc. in the United States or other countries. The companies and products mentioned in this operation manual can be the trade mark possesd by the owner of that trade mark right. 2 DVP-PLC Operation Manual
5 1 Introduction To ensure correct installation and operation of RTU-EN01, please read this manual carefully before using your RTU-EN01. RTU-EN01is an Ethernet remote I/O module for remote setting through Delta s DCISoft. RTU-EN01 supports maximum 256 digital input/output points. RTU-EN01 supports Modbus TCP protocol and can be used for remote monitoring with graphic control software or human machine interface. RTU-EN01 can also be used as a Modbus TCP gateway, supporting the conversion from Modbus TCP commands to Modbus ASCII/RTU. In addition, in MDI/MDI-X auto-detect, jump wire is not needed when you choose the network cable. 1.1 Features Supporting smart PLC functions, counter, timer and real-time clock. Able to operate independently without control of PLC main processing unit or programming. Able to auto-detect 10/100 Mbps transmission speed; MDI/MDI-X auto-detect. Supporting maximum 16 digital input/output modules (Max. 256 I/O points) and 8 analog input/output modules. Supporting maximum 16 sets of Modbus TCP connections. Supporting Modbus TCP/Modbus gateway (supporting Master mode, connectable to maximum 32 devices). Parameters can be set up on webpage. 1.2 Specifications Ethernet interface Interface RJ-45 with Auto MDI/MDIX Transmission method 802.3, 802.3u Transmission cable Transmission speed Communication protocol Category 5e, 100m (Max) 10/100 Mbps Auto-Detection Serial communication interface (COM1) Interface Transmission method Communication speed ICMP, IP, TCP, UDP, DHCP, NTP, Modbus TCP, HTTP Mini Dim RS ,200 bps Communication format Stop bit: 1; Parity bit: None; Data bit: 8 Communication protocol Transmission cable Delta Configuration Serial communication interface (COM2) Interface Transmission method DVPACAB215 / DVPACAB230 / DVPACAB2A30 3 PIN feed-through terminal RS-485 Transmission distance 1,200m Communication speed 110, 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps Communication format Stop bit: 1, 2; Parity bit: None, Odd, Even; Data bit: 7, 8 Communication protocol Modbus ASCII Modbus RTU DVP-PLC Operation Manual 3
6 Environment ESD (IEC , IEC ): 8KV Air Discharge EFT (IEC , IEC ): Power Line:±2KV, Digital Input: ±2KV, Communication I/O: ±2KV RS (IEC , IEC ): 80MHz ~ 100MHz, 10V/m. 1.4GHz ~ 2.0GHz, Noise immunity 10V/m Conducted Susceptibility Test (EN , IEC ): 150kHz ~ 80MHz, 3V/m Surge Test (Biwave IEC , IEC ): Power line 0.5KV DM, Ethernet 0.5KV CM, RS KV CM Operation 0ºC ~ 55ºC (temperature), 50 ~ 95% (humidity), pollution degree 2 Storage Shock/vibration immunity Certificates Electrical specification -25ºC ~ 70ºC (temperature), 5 ~ 95% (humidity) International standards: IEC , IEC (TEST Fc)/IEC & IEC (TEST Ea) Power supply voltage Power fuse capacity Power consumption Insulation voltage Weight 24VDC (-15% ~ 20%) (with DC input polarity reverse protection) 1.85A/30VDC, Polyswitch 2W 500VDC 116g 2 Product Profile & Outline 2.1 Dimension LAN RUN POWER RUN BAT.LOW STOP RS-232 RS-485 RTU-EN01 Unit: mm 4 DVP-PLC Operation Manual
7 2.2 Product Profile 2.3 LED Indicators 1. POWER indicator 12. RS-485 communication port 2. RUN indicator 13. Extension module positioning hole 3. BAT.LOW indicator 14. Nameplate 4. RUN/STOP switch 15. Extension port 5. RS-232 indicator 16. DIN rail (35mm) 6. RS-485 indicator 17. Extension module fixing clip 7. LINK/ACK indicator 18. DIN rail clip 8. SPEED indicator 19. Power supply port 9. Digital display 20. 3P terminal block (standard accessory) 10. Ethernet communication port 11. RS-232 communication port LED Color Function 21. Power supply connection cable (standard accessory) POWER Green Power supply indication RUN Green RUN/STOP indication BAT.LOW Red Battery in low power indication RS-232 Yellow Displaying communication status of RS-232 port RS-485 Yellow Displaying communication status of RS-485 port LINK/ACT Green Displaying the status of network SPEED Yellow Displaying the speed of network connection DVP-PLC Operation Manual 5
8 2.4 RUN/STOP Switch Status Explanation RUN STOP RUN RUN STOP STOP STOP RUN 1. RUN indicator on RTU-EN01 is ON. 2. Analog input/output module is in RUN status. 3. Smart PLC function is running. 1. Analog input/output module switches from RUN to STOP status. 2. Y points on digital input/output module are all OFF. 1. RUN indicator on RTU-EN01 is OFF. 2. Analog input/output module is in STOP status. 3. Smart PLC function stops. 1. RTU-EN01 re-detects the information on the right-side module. 2. Analog input/output module switches from STOP to RUN status. 2.5 RJ-45 PIN Definition PIN Signal Definition PIN Signal Definition 1 Tx+ 2 Tx- 3 Rx+ Positive pole for data transmission Negative pole for data transmission Positive pole for data receiving 5 -- N/C 6 Rx- Negative pole for data receiving 7 -- N/C 4 -- N/C 8 -- N/C 2.6 RS-232 PIN Definition PIN Signal Definition PIN Signal Definition 1 -- N/C 5 Tx Transmission data 2 -- N/C 6 -- N/C 3 -- N/C 7 -- N/C 4 Rx Reception data 8 GND Ground 2.7 RS-485 PIN Definition PIN Signal Definition 1 SG Ground of data 2 D- Negative pole for data 3 D+ Positive pole for data Installation & Wiring In this section, we will introduce how to connect RTU-EN01 to other devices and the network. 3.1 Connecting RTU-EN01 to DVP Slim Series Digital Input/Output Module Open the fixing clips on the right top and bottom sides on RTU-EN01. Meet the extension port on RTU-EN01 and the digital input/output module. Press and fix the clips on the digital input/output module. Make sure the contact between the modules is fine. 6 DVP-PLC Operation Manual
9 R S R S RTU-EN01 Modbus TCP Remote I/O Communication Module RTU-EN01 LA N RUN POWER RUN BAT.LOW STOP DVP-16SP DVP-02DA 3.2 Installing RTU-EN01 and DVP Slim Series Digital Input/Output Module onto DIN Rail Use standard 35mm DIN rail. Open the DIN rail clips on RTU-EN01 and the digital input/output module and insert the modules onto the rail. Press the clips to fix the modules onto the rail. 35mm DIN rail DVP-16SP DVP-02DA 3.3 How to Connect RTU-EN01 to Network Connect RTU-EN01 to the Ethernet hub by CAT-5e twisted pair. Since RTU-EN01 has Auto MDI/MDIX function, CAT-5e twisted pair does not need to jump wire. See below for the connection between the PC and RTU-EN01 modules: DVP-PLC Operation Manual 7
10 DVP-08ST DVP-04AD DVP-04TC DVP-04PT Modbus TCP Remote I/O Communication Module RTU-EN01 DVPEN01-SL DVP28SV DVP28SV PC RUN STOP Ethernet DVP-16SP DVP-02DA COM2 4 Word Devices & Bit Devices in RTU-EN Basic Registers (BR) RTU-EN01 DI/DO AI/AO BR# Attribute Content Explanation Default Latched 0 R Model name 1 R Firmware version 2 R 3 R/W Release date of the version Start/Stop PLC function Set up by the system; read only. The model code of RTU-EN01= H Displaying the current firmware verision in hex, e.g. V1.2 is indicated as high byte = 0x01 and low byte = 0x20. Displaying the data in decimal form. 10,000s digit and 1,000s digit are for month ; 100s digit and 10s digit are for day. For 1s digit: 0 = morning; 1 = afternoon. Example: indicates the version released in the afternoon of December 19. H 0600 YES 4 Reserved. NO 5 R/W COM2 communication settings RS-485 communication settings. Please refer to the table of baud rate setting and communication format setting. YES YES NO H 0368 YES 6 R/W Address For setting up the station address K 1 YES 7 R Number of DI points Range: 0 ~ 256 NO 8 R Number of DO points Range: 0 ~ 256 NO 9 R Error code Displaying the errors. Please refer to the table of error codes. NO 10 Reserved NO 11 R/W 12 R/W 13 R/W Communication time-out Communication delay time TCP connection idle time For setting up the communication time-out (ms) in Modbus TCP mode. For setting up the minimum interval time between every communication datum. K 5000 YES K 0 YES For setting up idle time for TCP communication. Unit: second K 30 YES 14 ~ 22 Reserved NO 23 R Number of analog I/O modules Max. 8 NO 8 DVP-PLC Operation Manual
11 BR# Attribute Content Explanation Default Latched 24 R 25 R 26 R 27 R 28 R 29 R 30 R 31 R ID of the 1st analog I/O module ID of the 2nd analog I/O module ID of the 3rd analog I/O module ID of the 4th analog I/O module ID of the 5th analog I/O module ID of the 6th analog I/O module ID of the 7th analog I/O module ID of the 8th analog I/O module ID of the 1st analog I/O module ID of the 2nd analog I/O module ID of the 3rd analog I/O module ID of the 4th analog I/O module ID of the 5th analog I/O module ID of the 6th analog I/O module ID of the 7th analog I/O module ID of the 8th analog I/O module 32 ~ 49 Reserved NO 50 R/W RTC settings Settings of the real-time clock NO 51 R/W Year Range: 1970 ~ 2099 YES 52 R/W Week Range: 1 ~ 7 YES 53 R/W Month Range: 1 ~ 12 YES 54 R/W Day Range: 1 ~ 31 YES 55 R/W Hour Range: 0 ~ 23 YES 56 R/W Minute Range: 0 ~ 59 YES 57 R/W Second Range: 0 ~ 59 YES 58 ~ 59 Reserved NO 60 Reserved NO 61 ~ 63 Reserved 0 NO Symbol R refers to ready only; R/W refers to read and write. NO NO NO NO NO NO NO NO 4.2 Explanations on BR BR#0: Model Name Explanations: 1. Model code of RTU-EN01 = H You can read the model code in the program to see if the extension module exists. BR#1: Firmware Version Explanations: The firmware version of RTU-EN01 is displayed in hex, e.g. H 0100 indicates version V1.00 BR#2: Release Date of the Version Explanations: Displaying the data in decimal form. 10,000s digit and 1,000s digit are for month ; 100s digit and 10s digit are for day. For 1s digit: 0 = morning; 1 = afternoon. Example: indicates the version released in the afternoon of December 19. DVP-PLC Operation Manual 9
12 BR#5: COM2 Communication Settings Explanations: Content Explanation Content Content 0x02 0x03 Interface COM2 RS-485 Stop bit 0: 1 Stop bit 1: 2 Stop bits Data b0 ~ b3 Baud rate (bps) Data Explanation Baud rate (bps) Data Baud rate (bps) 0x x6 2,400 0xB 57,600 0x x7 4,800 0xC 115,200 0x x8 9,600 0x x9 19,200 0x5 1,200 0xA 38,400 b4 ~ b7 b7 b6 ~ b5 b4 Parity bit 00 : None parity bit 01 : Odd parity bit 11 : Even parity bit Data bit 0 : 7 Data bits 1 : 8 Data bits 0000 (0) 7-N (3) 8-O (8) 7-N (B) 8-O (1) 8-N (6) 7-E (9) 8-N (E) 7-E (2) 7-O (7) 8-E (A) 7-O (F) 8-E-2 b8 ~ b15 Explanation Modbus RTU Master Modbus ASCII Master BR#6: Address Explanations For filling in or reading the Modbus address. The address will be displayed in the message display after being set up. Range: 1 ~ 247. BR#7: Number of DI Points Explanations Read the number of digital input points from BR#7. Range: 0 ~ 256. Max. I/O points: 256. BR#8: Number of DO Points Explanations Read the number of digital output points from BR#8. Range: 0 ~ 256. Max. I/O points: 256. BR#9: Error Code Explanations: Error code = 0 refers to no error occurring. Code Indication How to correct 10 DVP-PLC Operation Manual
13 Code Indication How to correct F0 Returning to default setting -- F1 RTU-EN01 being powered -- F2 Power supply in low voltage Check if the power supply of the module works normally. F3 Internal error. Manufacturing error. 1. Check if the settings of smart PLC are incorrect. 2. Re-power RTU-EN01. If the error still exists, try step Reset RTU-EN01. If the error still exists, send the module back to the manufacturer for repair. F5 Network connection error Check if RTU-EN01 is connected normally to the network. F6 Insufficient TCP connection Check if the number of connected modules exceeds the maximum. F7 RS-485 setting error Check if the RS-485 communication format is correct. F8 F9 IP setting error Right-side module error 04 Slave error 0b No response from station 1. DHCP request failure. 2. IP setting error. 3. MASK setting error. 4. Gateway does not exist in the same subnet. 5. Returning to default setting. Check if the configuration of the right-side module has been modified. If the error still exists, check if the number of I/O points exceeds the maximum and whether the there are more than 8 analog I/O modules connected. 1. Check if RTU-EN01 and RS-485 is connected normally. 2. Check if the series transmission speed is consistent with that of other nodes on the network. BR#11: Communication Time-out (ms) Explanations: For setting up the communication time-out. Default = 5,000ms. For example, if you wish to set up the communication time-out to 7 seconds manually, write 7000 to BR#11. Range: 5 ~ 65,535. BR#12: Communication Delay Time (ms) Explanations: For setting up the minimum interval time between every Modbus command. Default = 0ms. For example, if you wish to set up the communication delay time to 100ms manually, write 100 into BR#12. Range: 0 ~ 65,535. BR#13: TCP Connection Idle Time (s) Explanations: For setting up the TCP connection idle time. Default = 30 seconds. For example, if you wish to set up the idle time to 7 seconds manually, write 7 into BR#13. Range: 5 ~ 65,535. BR#23: Number of Analog I/O Modules Explanations: Read the number of right-side modules from BR#23. Max. 8. BR#24 ~ #31: ID of the 1 st ~ 8 th Analog I/O Module Explanations: Read the ID of the 1 st ~ 8 th analog I/O modules from BR#24 ~ BR#31. DVP-PLC Operation Manual 11
14 BR#50 ~ BR#57: RTC Settings Explanations: For setting up the real-time clock (RTC). When BR#9 = 1, RTU-EN01 will stop to update the RTC values to BR#10 ~ #16. Once the setup is completed, RTU-EN01 will set BR#9 to 0. Allowed range for RTC: 1970/01/01 00:00:00 ~ 2037/12/31 23:59:59 BR#9 0 No action 1 RTC stops 2 RTC being set 4.3 External Input Contacts (RX) RX# Attribute Content Explanation Default Latched 0 ~ 255 R/W External input contact Input points on analog I/O module OFF NO Symbol R refers to ready only; R/W refers to read and write. RX#0 ~ #255: External Input Contact Explanations: The right-side extension interface on RTU-EN01 is able to connect to DVP-Slim series digital I/O modules. RTU-EN01 supports maximum 256 I/O points. 4.4 External Output Contacts (RY) RY# Attribute Content Explanation Default Latched 0 ~ 255 R/W External output contact Output points on analog I/O module OFF NO Symbol R refers to ready only; R/W refers to read and write. RY#0 ~ #255: External Output Contact Explanations: The right-side extension interface on RTU-EN01 is able to connect to DVP-Slim series digital I/O modules. RTU-EN01 supports maximum 256 I/O points. 4.5 Control Register for Extension Modules (RCR) RCR# Attribute Content Explanation Default Latched 0 ~ 49 R/W 50 ~ 99 R/W 100 ~ 149 R/W 150 ~ 199 R/W The 1 st analog I/O module The 2 nd analog I/O module The 3 rd analog I/O module The 4 th analog I/O module Control register for the 1 st analog I/O module Control register for the 2 nd analog I/O module Control register for the 3 rd analog I/O module Control register for the 4 th analog I/O module -- NO -- NO -- NO -- NO 12 DVP-PLC Operation Manual
15 RCR# Attribute Content Explanation Default Latched 200 ~ 249 R/W 250 ~ 299 R/W 300 ~ 349 R/W 350 ~ 399 R/W The 5 th analog I/O module The 6 th analog I/O module The 7 th analog I/O module The 8 th analog I/O module Symbol R refers to ready only; R/W refers to read and write. Control register for the 5 th analog I/O module Control register for the 6 th analog I/O module Control register for the 7 th analog I/O module Control register for the 8 th analog I/O module -- NO -- NO -- NO -- NO RCR#0 ~ #399: Control Register for Right-Side Analog I/O Modules Explanations: By reading/writing RCR in RTU-EN01, you are able to store or retrieve the data in the control register (CR) inside the analog input/output module. Example: RCR#0 corresponds to CR#0 in the 1 st analog I/O module. RCR#260 corresponds to CR#10 in the 6 th analog I/O module. Extension module closest to RTU-EN01 is regarded the 1 st module. 4.6 Word Devices & Bit Devices for Timers (T) T# Attribute Register/coil name Explanation Default Latched 0 R/W Timer 0 Timer 0/OFF NO 1 R/W Timer 1 Timer 0/OFF NO 2 R/W Timer 2 Timer 0/OFF NO 3 R/W Timer 3 Timer 0/OFF NO 4 R/W Timer 4 Timer 0/OFF NO 5 R/W Timer 5 Timer 0/OFF NO 6 R/W Timer 6 Timer 0/OFF NO 7 R/W Timer 7 Timer 0/OFF NO 8 R/W Timer 8 Timer 0/OFF NO 9 R/W Timer 9 Timer 0/OFF NO 10 R/W Timer 10 Timer 0/OFF NO 11 R/W Timer 11 Timer 0/OFF NO 12 R/W Timer 12 Timer 0/OFF NO 13 R/W Timer 13 Timer 0/OFF NO 14 R/W Timer 14 Timer 0/OFF NO 15 R/W Timer 15 Timer 0/OFF NO Symbol R refers to ready only; R/W refers to read and write. T#0: Timer 0 Explanations: When the timer is enabled, it will start to time according to the settings. When the timing reaches the target, the bit device T0 will be ON. When the bit device is reset, the word device will be reset to 0 as well. DVP-PLC Operation Manual 13
16 T#1 ~ #15: Timer 1 ~ 15 Explanations: Please refer to T# Word Devices & Bit Devices for Counters (C) C# Attribute Register/coil name Explanation Default Latched 0 R/W Counter 0 Counting up/down counter 0/OFF NO 1 R/W Counter 1 Counting up/down counter 0/OFF NO 2 R/W Counter 2 Counting up/down counter 0/OFF NO 3 R/W Counter 3 Counting up/down counter 0/OFF NO 4 R/W Counter 4 Counting up/down counter 0/OFF NO 5 R/W Counter 5 Counting up/down counter 0/OFF NO 6 R/W Counter 6 Counting up/down counter 0/OFF NO 7 R/W Counter 7 Counting up/down counter 0/OFF NO 8 R/W Counter 8 Counting up/down counter 0/OFF NO 9 R/W Counter 9 Counting up/down counter 0/OFF NO 10 R/W Counter 10 Counting up/down counter 0/OFF NO 11 R/W Counter 11 Counting up/down counter 0/OFF NO 12 R/W Counter 12 Counting up/down counter 0/OFF NO 13 R/W Counter 13 Counting up/down counter 0/OFF NO 14 R/W Counter 14 Counting up/down counter 0/OFF NO 15 R/W Counter 15 Counting up/down counter 0/OFF NO Symbol R refers to ready only; R/W refers to read and write. C#0: Counter 0 Explanations: When the counter is enabled and RX turns from OFF to ON, counting up or counting down will be set according to the settings. When the counting reaches the target, the counting will stop, and the bit device C0 will be set to ON. When the bit device is reset, the word device will be reset to 0 as well. C#1 ~ #15: Counter 1 ~ 15 Explanations: Please refer to C# Bit Devices for Real-Time Clock (R) R# Attribute Content Explanation Default Latched 0 R/W RTC 0 Real-time clock OFF NO 1 R/W RTC 1 Real-time clock OFF NO 2 R/W RTC 2 Real-time clock OFF NO 3 R/W RTC 3 Real-time clock OFF NO 4 R/W RTC 4 Real-time clock OFF NO 5 R/W RTC 5 Real-time clock OFF NO 14 DVP-PLC Operation Manual
17 R# Attribute Content Explanation Default Latched 6 R/W RTC 6 Real-time clock OFF NO 7 R/W RTC 7 Real-time clock OFF NO 8 R/W RTC 8 Real-time clock OFF NO 9 R/W RTC 9 Real-time clock OFF NO 10 R/W RTC 10 Real-time clock OFF NO 11 R/W RTC 11 Real-time clock OFF NO 12 R/W RTC 12 Real-time clock OFF NO 13 R/W RTC 13 Real-time clock OFF NO 14 R/W RTC 14 Real-time clock OFF NO 15 R/W RTC 15 Real-time clock OFF NO Symbol R refers to ready only; R/W refers to read and write. R#0: RTC 0 Explanations: When the RTC function is enabled, and the assigned trigger condition is true, RTU-EN01 will set the bit device R0 to ON and continue to output or stop according to the set time. R#1 ~ #15: RTC 1 ~ 15 Explanations: Please refer to R#0. 5 Modbus Communication 5.1 Function Codes Supported Function code Explanation Devices supported 0x02 Read digital input point RX, RY, T, R, C 0x03 Read register BR, T, C, RCR 0x05 Write single bit device RY, T, R, C 0x06 Write single register BR, T, C, RCR 0x0F Write multiple bit devices RY, T, R, C 0x10 Write multiple registers BR, T, C, RCR 0x17 Read/write multiple registers BR, T, C, RCR 5.2 Exception Codes Supported Exception code 0x01 0x02 0x03 0x04 0x0b Explanation Illegal function Illegal data address Illegal data value Slave device failure Gateway target device failed to respond. DVP-PLC Operation Manual 15
18 5.3 Device Type & Device Address Discrete input Device type Modbus address (Hex) 6-digit Modbus address (Dec) Number RX 0x0400 ~ 0x04FF ~ Coil RY 0x0500 ~ 0x05FF ~ T 0x1600 ~ 0x160F ~ R 0x1900 ~ 0x190F ~ C 0x1E00 ~ 0x1E0F ~ Holding register Device type Modbus address (Hex) 6-digit Modbus address (Dec) Number BR 0x0000~0x ~ T 0x1600~0x160F ~ C 0x1E00~0x1E0F ~ RCR 0x3000~0x ~ Setting up Software This section gives instructions on how to set up RTU-EN01 by DCISoft and explanations on each setup page. RTU-EN01 is set up by UDP port 20006; therefore, you have to be aware of the relevant settings of the firewall. See the explanations below on the software. 6.1 Setting up Communications & Searching for Communication Modules in DCISoft Broadcast search 1. Open DCISoft on the PC and click on the IP Search icon. 16 DVP-PLC Operation Manual
19 2. You will see the communication module found. DVP-PLC Operation Manual 17
20 3. Double-click on the module to be set up to enter the setup page. The first page overviews the basic status of the module and information on the right-side module. 4. The next page is for basic network setup. Consult your Internet Service Provider for relevant network setting. For other settings, see BR#11 ~ BR# Recording IP Address The IP list allows the user to select modules directly and designate a module for search. Recording IP address means to add this RTU-EN01 to the list, allowing the user to see RTU-EN01 in the search. Recording IP address 18 DVP-PLC Operation Manual
21 IP list: In the list, you will see the network IPs already used. Click Add to record the known IP address into the list and next search for the module on the network by designated IP. Click the icon to search for the module. 6.3 Basic Settings The basic settings include parameters such module name, network settings and communication time. The basics DVP-PLC Operation Manual 19
22 1. Module name: There can be many RTU-EN01 modules on the network. Thus, you can set up a module name for each module to identify the module when you need to use them. 2. Network setup: Enable dynamic IP (DHCP) or static IP. Consult your ISP for other relevant settings. A. IP configuration: There are 2 types of IP, static IP and DHCP. Static IP: Preset or manually modified by the user. DHCP: Automatically updated by the server. There must be a server in the LAN. IP Static DHCP Explanation The user enters the IP address, subnet mask and gateway. DHCP server offers the IP address, subnet mask and gateway. B. IP address: IP address is the location of the equipment on the network. Every equipment connected to the network has to have an IP address. Incorrect IP address will result in connection failure. Consult your ISP for how to set up IP address. The default IP for RTU-EN01 is C. Netmask: Subnet mask is an important parameter for setting up the subnet, used for seeing if the destination IP and the local equipment are in the same subnet. If not, the equipment will send the packet to the gateway, and the gateway will send the packet to another subnet. Incorrect setting may cause the destination equipment unable to communicate to RTU-EN01. To see if your setting is correct, conduct bitwise AND operations between your IP and subnet mask and destination IP and subnet mask. If the two values obtained are the same, the two IPs are in the same subnet. The default subnet mask of RTU-EN01 is D. Gateway: Gateway is the window for two different subnets, allowing the two ends in different subnets to communicate. For example, if the LAN has to be connected to WAN, it will need a gateway to bridge 20 DVP-PLC Operation Manual
23 the communication. The IP of the gateway has to be in the same subnet as RTU-EN01. The default gateway of RTU-EN01 is Timer setting: For setting up TCP connection idle time, Modbus time-out and minimum delay time for every communication data. Please refer to the explanations on BR#11, BR#12, and BR# Network Settings The first step for all the equipment to connect to the network is to have its own IP (Internet Protocol) address. The IP address is like a number for every equipment to be identified on the network. Setting up static IP of the PC 1. Enter Control Panel Network Connection click Local Area Connection". 2. You will see the Local Area Connection Status window. Click Properties. 3. Click Internet Protocol (TCP/IP). DVP-PLC Operation Manual 21
24 4. Enter into IP address. Click OK to complete the IP address setting of the PC. 6.5 Setting up Time Server RTU-EN01 offers real-time clock (RTC) functions. You can set up your own time for RTU-EN01 or update the time through NTP server. Setup page 22 DVP-PLC Operation Manual
25 1. Enable time server: RTU-EN01 execute automatic time correction from the NTP server on the network every 6 hours to ensure the time is correct in the RTC. To enable this function, you have to set up first the IP address of the NTP server and the time zone and daylight saving time which your RTU-EN01 is in. 2. Start daylight saving time Daylight Saving Time; also known as summer time, is a conventional local time adopted by many countries in the world on a seasonal basis. Most commonly DST is obtained by adjusting the official local time forward, by one hour, for the spring, summer, and early autumn periods. 3. Time server: IP address of the time server. You can acquire correct time from the time server to correct the time in the MPU. 4. Time zone: There are 24 time zones on earth and follow Greenwich Mean Time (GMT) as the standard time. Select the time zone you are in and adjust the offset between the time of your city and Coordinated Universal Time (UTC). 5. Clock setup: Set up the time in RTU-EN01. You can set the time to the same as the PC in operation, or you may as well set up the time manually. 6.6 IP Filter The IP filter is used for restricting the connection of the network in case some uncertain UP will cause errors. Only the IP set within a certain range can establish a connection. Other IPs will be rejected. Setting up IP filter 1. Enable IP filter: DVP-PLC Operation Manual 23
26 Check the box to enable IP filter. 2. Begin IP address: Start IP addresses allowed to establish connection. Max. 8 IPs are allowed. 3. End IP address: End IP addresses allowed to establish connection. Max. 8 IPs are allowed. 6.7 Smart PLC Setting: IF-THEN RTU-EN01 has the independent Smart PLC function. IF-THEN is able to execute the corresponding function of the condition set up by the user and combine with the functions of counter, timer, RTC, digital I/O points and analog I/O modules. You can use AND or OR as the trigger condition. There are 16 IF-THEN functions in RTU-EN01. IF-THEN 1. Enable: Check the box to enable IF-THEN. 2. IF: For the trigger condition, you can select bit devices RX, RY, C, T, RT or word device RCR and set them to ON, OFF, Rising, Falling, >, <, =, <>, >= or <=. The trigger condition can be AND or OR. When the device is a register, the allowed trigger range will be K-32,768 ~ K32, THEN: For the execution, you can select bit devices RY, C, T, RT or word device RCR and set them to Set, Reset, Toggle or set up a value for them. Please refer to the explanations on IF#13 ~ IF#24. When the device is a register, the allowed trigger range will be K-32,768 ~ K32, Add, Modify, Clear, Delete: All the settings above can be added to the IF-THEN table below, or you can modify, clear or delete the settings. 5. Up, Down: 24 DVP-PLC Operation Manual
27 You can move the IF-THEN setting upwards or downwards to change the execution order of them. 6.8 Smart PLC Setting: Timer RTU-EN01 has the independent Smart PLC function. The timer is able to time following the system time. There are 16 timers in RTU-EN01. The timing range is 10ms ~ 655,35s. Timer 1. Enable: Decide whether to enable the timer in this column. 2. Cyclic: Decide whether to reset the timer and re-start the timing when the timing reaches the target in this column. 3. Reset when STOP->RUN: Decide whether to reset the timer when the system goes from STOP to RUN. 4. Timeout bound: The time for the timer to reach the target. Range: 10ms ~ 65,535s. 6.9 Smart PLC Setting Counter RTU-EN01 has the independent Smart PLC function. The counter can be triggered by the external input points RX. When RX turns from OFF to ON, the counter will start to count. There are 16 counters in RTU-EN01, responsible for counting up and counting down. The counting range is -32,768 ~ 32,767. Counter DVP-PLC Operation Manual 25
28 1. Enable: Decide whether to enable the counter in this column. 2. Count up/count down: Decide whether the counter will be counting up or counting down. 3. Up bound/low bound: The upper bound and lower bound of the counting. Range: -32,768 ~ 32, Count source RX NO.: No. of the external input point RX of the counting source. Range: RX#0 ~ RX# Smart PLC Setting RTC RTU-EN01 has the independent Smart PLC function. The real-time clock (RTC) can be triggered by the system at specific time. There are 16 RTCs in RTU-EN01. You can designate the trigger time or trigger the RTC on a monthly, weekly or daily basis. Please refer to the explanations on RS#0 ~ RS#159. RTC 26 DVP-PLC Operation Manual
29 1. Enable: Decide whether to trigger the RTC in this column. 2. Cyclic: Decide to trigger the RTC only once, or trigger it on a daily, weekly or monthly basis. 3. Output auto-reset: After the RTC is triggered, decide whether to retain the output for a period of time and reset the RTC automatically. R (Coil) will be OFF when the time for reset is reached. 4. Auto-reset time, Unit: If you select to auto-reset the RTC, the bit device in RTC will retain the output for a period of time. Range: 1s ~ 24hr. Range for second as unit: 1 ~ 32,767 Range for minute as unit: 1 ~ 3,600 Range for hour as unit: 1 ~ Year, Month, Day, Hour, Minute, Second, Week: The time to trigger the RTC. If you would like to trigger it only once, only Year, Month, Day, Hour, Minute and Second need to be set. If you would like to trigger on a daily basis, only Hour, Minute and Second need to be set. If you would like the RTC to be triggered on a weekly basis, you only need to set up Week, Hour, Minute and Second. If the RTC is triggered monthly, set up only Day, Hour, Minute and Second Analog Input/Output Modules RTU-EN01 offers control registers (CR) for analog I/O modules and is built-in with mapping tables of CR for read/write. The user can check the CR to be read/written and use Delta s communication module DVPEN01-SL to map the CR directly to D registers in DVP-SV series PLC and read/write the D register through PLC program, controlling the analog I/O module connected to RTU-EN01. RTU-EN01 supports maximum 64 data reading/writing. This function works with DVPEN01-SL of firmware V2.0 or versions above. Analog I/O modules DVP-PLC Operation Manual 27
30 1. Corresponding table: Open DCISoft and it will automatically load in the control register information on the analog I/O modules. (When using Web settings, you have to load in the EDS file for analog I/O module by yourself.) Check the CR you are to read or write to establish a mapping table. DVPEN01-SL will map the CR established in the table to D register in DVP-SV series PLC. The user will be able to operate the analog I/O module connected to RTU-EN01 by the value stored in D register. 2. Read: Check the CR (read) to be added to the mapping table. Click Apply and the checked CR will be added. 3. Write: Check the CR (write) to be added to the mapping table. Click Apply" and the checked CR will be added. 4. Clean mapping list: Once applied, clear all the information in the mapping table. 5. CR No.: The number of control register for all analog I/O modules connected to RTU-EN R/W: Indicating whether the CR can be read or written. 7. Register name: The name of the CR for the analog I/O modules. 8. Present value: The present value in the CR for the analog I/O modules. 9. Format: The display format for the present value in the CR. Available formats: hex, signed decimal integer and binary integer. 28 DVP-PLC Operation Manual
31 6.12 I/O Monitoring Table RTU-EN01 is able to monitor internal registers on-line. Scroll the table to monitor bit devices RX, RY, T, C, R, RCR and BR and the bit status and present value in the register. You can choose to monitor decimal or hex present value. I/O monitoring table: 1. Device: Select an internal register in RTU-EN01. Bit devices: RX, RY, T, C, R Registers: T, C, R, RCR, BR. 2. Number: Select the bit devices and registers to be monitored by their numbers. RX#0 ~ RX#255, total 256 bits. RY#0 ~ RY#255, total 256 bits. DVP-PLC Operation Manual 29
32 T#0 ~ T#15, total 16 bits and 16 registers. C#0 ~ C#15, total 16 bits and 16 registers. R#0 ~ R#15, total 16 bits and 16 registers. RCR#0 ~ RCR#399, total 400 registers. BR#0 ~ BR#63, total 64 registers. 3. Format: Select the format of the register to be monitored, decimal (Dec) or hexadecimal (Hex). Once the number and format are set, click Apply to save the setting and start the monitoring. 4. Start/Stop monitor: Start or stop the saved and applied device number to be monitored. Unapplied saved settings will be deleted Setting up Gateway RTU-EN01 offers Modbus TC P to RS-485 gateway functions. By setting up RTU-EN01, you can read the data in specific devices on the network. Gateway functions help you fast store and retrieve data and offers on-line monitoring for maximum 100 bit data and word data. The data can be temporarily stored in RTU-EN01, speeding up the write/read and response time. Gateway setup page 1. COM Setup COM2 Mode (RS-485): You can choose Modbus ASCII Master, Modbus RTU Master or Virtual COM. Baudrate: The baud rate for communication. 30 DVP-PLC Operation Manual
33 Parity Data length Stop bits Station address: The Modbus address. 2. Bit device For setting up the addresses for the bit type serial slave device and reading or the content in the designated slave. Station address: Enter the address of slave to be monitored. (Max. 16 slaves) MODBUS (Hex): Enter the 4-digit hex Modbus address of the slave to be monitored. MODBUS (Dec): Enter the 6-digit decimal Modbus address of the slave to be monitored. Account: Enter the number of slaves to be monitored continuously (Max. 100). DVP-PLC Operation Manual 31
34 3. Word device For setting up the addresses for the word type serial slave device and reading or the content in the designated slave. Station address: Enter the address of slave to be monitored. (Max. 16 slaves) MODBUS (Hex): Enter the 4-digit hex Modbus address of the slave to be monitored. MODBUS (Dec): Enter the 6-digit decimal Modbus address of the slave to be monitored. Account: Enter the number of slaves to be monitored continuously (Max. 100). Once the information of slave monitoring is set, click "Apply" to save the setting and start the monitoring. Incomplete device information will be deleted. Format: Select the format of the register to be monitored, decimal (Dec), hexadecimal (Hex) or binary. Start/Stop monitor Start or stop the saved and applied device number to be monitored. Unapplied saved settings will be deleted. Note: The default is in cache enabled mode. You can set up maximum 16 sets of slave information for the monitored bits and words (Max. 100 data). Under the cache mode, you are able to send the read data back to the registers in RTU-EN DVP-PLC Operation Manual
35 6.14 Virtual COM The virtual COM converts the data sent to RS-232 port into Ethernet. Select Virtual COM for COM2 mode (RS-485). The default setting for listen port is Open the setup page for Virtual COM. DVP-PLC Operation Manual 33
36 Press Search, and you will see all the connected devices on the network Select the device and click OK. Information on the device will be loaded in automatically. Press OK to complete the setup. Once the setup is completed, you will then be able to see the virtual COM just set in Computer Management. 34 DVP-PLC Operation Manual
37 6.15 Security Setting To prevent the set values in RTU-EN01 from being modified, you can set up passwords to lock the settings in RTU-EN01. Setting up password 1. Login: Log in to check and modify parameters. 2. Password setup: Check the Modify box to set up the password. 3. Password: Enter maximum 4 characters. Leave it blank to clear the password. 4. Confirm password: Enter the new password again. Note: Once the password is locked, all the pages cannot be set up unless you unlock the password. DVP-PLC Operation Manual 35
38 However, if you set up RTU-EN01 by RS-232, you can return the setting to default one whether the password is locked or not. For example, if you have locked RTU-EN01 but forget the password, you have to return RTU-EN01 to default setting by RS-232, and all the settings will return to default ones Returning to Default Settings If you need to clear all the settings after many modifications have been done on the settings and return the settings to default ones, check the Factory Setting box. Returning to default settings Check Factory Setting box and click on Yes. Note: If you set up RTU-EN01 by RS-232, you can return to settings to default ones whether the password is locked or not. It will take approximately 10 seconds to return to default settings, so DO NOT switch off the power within the 10 seconds Web Function RTU-EN01 offers Web function for the user to connect through Internet browser (e.g. Internet Explorer). You can set up and monitor RTU-EN01 by this function. 1. See the connection method (as below) and 6.1 for how to set up communication. 36 DVP-PLC Operation Manual
39 RTU-EN 01 DVP-08 ST DVP-04 AD DVP-04 TC DVP-04 PT Modbus TCP Remote I/O Communication Module RTU-EN01 PC Ethernet DVP-16S P DVP-02 DA COM2 RTU-EN01 DI/DO AI/AO 2. Open Internet Explorer and enter IP address (default) of RTU-EN01. You can also copy the IP address of RTU-EN01 in DCISoft and paste it to the address column on IE. Press Enter on keyboard to open the webpage. DVP-PLC Operation Manual 37
40 3. To use the page of analog input/output modules on the web, download DeltaR-Side-S_ENU.eds file from Delta s website first and import the file to the page. Other settings are the same as the settings in DCISoft. The webpage supports Java Runtime Environment (JRE) v1.4.2_xx and versions above. 4. Webpage troubleshooting Unable to connect: (1) Check if Java is correctly installed. Connect to the Java page to confirm. (2) Check Proxy settings. Close Proxy or set up exceptions. Close Proxy: 1. In IE, select Tool => Internet Options. 38 DVP-PLC Operation Manual
41 2. Select Connections and Click LAN Settings ". 3. Uncheck Proxy server options and click "OK. DVP-PLC Operation Manual 39
42 Set up exceptions: 1. Click Advanced on Local Area Network (LAN) Settings page. 2. Enter the IP address of RTU-EN01 in Exceptions. 3. Click OK. Abnormal webpage action: In this case, please clear your temporary Internet files. Clear temporary Internet files: 1. In IE, select Tool => Internet Options. 40 DVP-PLC Operation Manual
43 2. In General page, click Delete Files in Temporary Internet files column. 3. Check Delete all offline content and click "OK to start the deletion. 4. Click OK to leave the General page. DVP-PLC Operation Manual 41
44 RTU-EN 01 DVP-08 ST DVP-04 AD DVP-04 TC DVP-04 PT Modbus TCP Remote I/O Communication Module RTU-EN01 7 Application Examples DCISoft 7.15 Smart PLC: IF-THEN Application Steps Setting up IF-THEN in Smart PLC functions by using DCISoft. 1. When RX#0 and RX#1 are ON, set RY0 to output. 2. When RX#2 turns from OFF to ON, set RY1 to reversing its direction. 1. See the connection method (as below) and 6.1 for how to set up communication. PC Ethernet DVP-16S P DVP-02 DA COM2 RTU-EN01 DI/DO AI/AO 2. Open the setup page and switch to Smart PLC page. 3. Select RX 0 On and RX 1 On in the IF column and select AND for the relation between conditions. Next, select RY 0 Set in the THEN column and press Add to add the settings into the table below. 4. Select RX 2 Rising in the IF column and RY 1 Toggle in the THEN column. Press Add to add the settings into the table below. Press Apply to store these settings into RTU-EN DVP-PLC Operation Manual
45 7.16 Smart PLC: Timer Application Steps Setting up Smart PLC functions by DCISoft. After RY0 is On for 1 second, it will turn Off for 500 ms. This will repeat in cycle. (1) Set up the timer: Timer 0 1s, Timer 1 500ms. (2) Set up IF-THEN: When the timing reaches the target, RY0 will be On or Off. 1. Open the setup page and switch to Smart PLC page. Further switch to the Timer page. 2. Check to Enable Timer 0 and Timer 1 and set Timer 0 to 1s and Timer 1 to 500ms. Click Apply to write the settings into RTU-EN01. DVP-PLC Operation Manual 43
46 7.17 Smart PLC: Counter Application Steps Setting up the counter by DCISoft. Once RX#1 counts for 5 times, RY0 will output. (1) Set up counter C0: RX#1 counts up 5 times and reaches the target. (2) Set up IF-THEN: When the counting reaches the target, RY0 will output. 1. Open the setup page and switch to Smart PLC page. Further switch to the Counter page. 2. Check to Enable Counter 0, select Count Up, set Up Bound to 5 and Count Source RX NO. to RX 1. Click "Apply to write these settings into RTU-EN Switch to IF-THEN page and check the Enable box. Select C 0 On in the IF column and RY 0 Set in the THEN column. Click on Add to add the settings to the table below and press OK to save the settings into RTU-EN DVP-PLC Operation Manual
47 7.18 Smart PLC: RTC Application Steps Setting up Smart PLC function by DCISoft. RY0 turns On at 08:00 and Off at 09:00 every day. (1) Set up the RTC to be On at 08:00 every day and continue to be On for 1 hour. (2) Set up IF-THEN: When the timing reaches the target, RY0 will be On or Off. 1. Open the setup page and switch to Smart PLC page. Further switch to the RTC page. 2. Check to Enable RTC 0 and set Cyclic to Daily, Auto-Reset Time to 60 Minute and enabling time to 08:00:00. Press Apply to write the settings into RTU-EN01. DVP-PLC Operation Manual 45
48 3. Switch to IF-THEN page. Check the Enable box and select RT0 On in the IF column and RY 0 Set in the THEN column. Press Add to add the settings to the table below. 4. Check Enable and select RT0 Off in the IF column and RY 0 Reset in the THEN column. Press Add" to add the settings to the table bellow and click on OK to save the settings into RTU-EN Virtual COM Application Steps The virtual COM converts the data sent to RS-232 port into Ethernet. Virtual COM only connects to software supporting serial ports, e.g. Delta WPLSoft, VFDSoft, ASDASoft. See the examples below for how to connect VFD-E series AC motor drive to VFDSoft through by virtual COM. (1) Select user-defined protocol and set the communication parameters for serial master/slave to the same as the parameters in VFD-E. (2) Set up virtual COM. (3) Open Delta VFDSoft, set up the communication format and establish the connection. 1. Setting up virtual COM Select Virtual COM for COM2 mode (RS-485) and set up the same communication parameters as those in VFD-E. 46 DVP-PLC Operation Manual
49 The default setting for listen port is Open the setup page for Virtual COM. Press Search and you will see all the connected devices on the network. DVP-PLC Operation Manual 47
50 Select the device and click OK. Information on the device will be loaded in automatically. Press OK to complete the setup. Once the setup is completed, you will then be able to see the virtual COM just set in Computer Management. 2. Use Virtual COM in Delta VFDSoft. Open Delta VFDSoft. 48 DVP-PLC Operation Manual
51 Set up communication format Use the Virtual COM (COM2) previously set for the setting of Com Port. Next, enter the communication format (38400, 7, E, 1) for VFD-E. Click Test. Success flashing in green color means the communication test is successful. Click OK to establish a connection with VFD-D by VFDSoft. DVP-PLC Operation Manual 49
52 50 DVP-PLC Operation Manual
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
CMC-DN01 DeviceNet Slave Communication Card Operation Manual
CMC-DN01 DeviceNet Slave Communication Card Operation Manual 2011-12-26-A Warning This operation manual provides introduction on the functions, specifications, installation, basic operation and settings
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual CMC-0205820-01 Table of Content 1 Introduction to CMC-PD01... 2 1.1 Product Introduction... 2 1.2 Features... 2 2 Product Profile and Outline...
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER
User s Guide PMCM-ETHCC-0208 2/2008 ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER TABLE OF CONTENTS INTRODUCTION... 2 Supported Ethernet Protocols... 2 Hardware... 2 Meter Firmware...
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
EMG Ethernet Modbus Gateway User Manual
EMG Ethernet Modbus Gateway User Manual Rev 2.2 07/2010 CONTENTS 1. Introduction 1.1. General Features 1.2 Installing the Drivers 2. Configuration 2.1 Main Device Parameters 2.1.1 RS485 Serial Communication
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
NetBiter webscada Modbus User Manual
User Manual IntelliCom Innovation AB Pilefeltsgatan 93-95 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email [email protected] www www.intellicom.se Revision List Revision Date
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
7.7 Ethernet Communication (AFPX-COM5)
7.7 Ethernet Communication (AFPX-COM5) 7.7.1 AFPX-COM5 Overview The communication cassette AFPX-COM5 has an Ethernet interface at the COM1 port and a 3-wire RS232C interface at the COM2 port. The Ethernet
LBNP16312. RS-232/485/422 serial device server. User manual
Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
DSA-1000 / PRT-1000 Device Server / Thermal Printer
LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,
Ethernet Port Quick Start Manual
Ethernet Port Quick Start Manual THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE ETHERNET PORT OF EDI SIGNAL MONITORS with Ethernet Version 1.5 firmware. DETAILS OF THE ECCOM OPERATION ARE DESCRIBED
IP Power Stone 4000 User Manual
IP Power Stone 4000 User Manual Two Outlet Remote AC Power Controller Multi Link, Inc. 122 Dewey Drive Nicholasville, KY 40356 USA Sales and Tech Support 800.535.4651 FAX 859.885.6619 techsupport@multi
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
2015/02/07 05:41 1/23 WIZ550WEB Users' Guide
2015/02/07 05:41 1/23 WIZ550WEB Users' Guide WIZ550WEB Users' Guide Overview WIZ550web provides the lightweight webserver operating. It controls digital output or monitors digital and analogue input through
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
TK800-Series Industrial GPRS / UMTS / LTE Router
The new generation LTE with 100 Mbps LTE standard for high transmission rates and good network coverage in sparsely populated areas Dynamic Multipoint VPN GRE, L2TP, IPSec, DMVPN, OpenVPN Simple and fast
IP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
Serial Over IP Ethernet Device Server
NETRS2321E NETRS2321EEU NETRS2321EGB Instruction Manual Serial Over IP Ethernet Device Server 1 Port RS-232/422/485 Serial over IP Ethernet Device Server Manual Revision:10/13/2010 For the most up-to-date
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list
LW320/LW321 Sweex Wireless 300N Router Do not expose the Sweex Wireless 300N Router to extreme temperatures. Do not place the device in direct sunlight or in the direct vicinity of heating elements. Do
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
USING THE XPERT2 / 9210B ON A TCP/IP NETWORK
1 USING THE XPERT2 / 9210B ON A TCP/IP NETWORK Prepared by: R&D January, 2009 Sutron Corporation 21300 Ridgetop Circle Sterling, Virginia 20166 TEL: (703) 406-2800 FAX: (703) 406-2801 WEB: http://www.sutron.com/
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2
NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL
WiFly Evaluation Kit 2012 Roving Networks. All rights reserved. Version 1.32r 10/9/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks evaluation kits,
2 Setting Up the Hardware for a Wired Ethernet Network... 13. 3 Setting Up the Software for an Ethernet Network... 21
Contents 1 Networking Basics............................................... 1 Selecting a network connection........................................ 2 Wired Ethernet network...........................................
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
Linksys WAP300N. User Guide
User Guide Contents Contents Overview Package contents 1 Back view 1 Bottom view 2 How to expand your home network 3 What is a network? 3 How to expand your home network 3 Where to find more help 3 Operating
www.css-timemachines.com Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual
www.css-timemachines.com Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual Table of Contents 1. Introduction...1 2. Initial Setup...2 2.1 PoE...2 2.2 Network...2
TK700 +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router
+70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W The industrial 2G GPRS- and 3G UMTS routers offered by Welotec enables the access to Ethernet devices or a local network remotely via mobile network
Chapter 7 Troubleshooting
Chapter 7 Troubleshooting This chapter provides troubleshooting tips and information for your ProSafe VPN Firewall 200. After each problem description, instructions are provided to help you diagnose and
Medical Vacuum Systems-PXMI
Medical Vacuum Systems-PXMI Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
Wireless LAN Access Point. IEEE 802.11g 54Mbps. User s Manual
Wireless LAN Access Point IEEE 802.11g 54Mbps User s Manual Table of Contents Chapter 1 Introduction... 1 1.1 Package Contents...2 1.2 Features...2 1.3 Specifications...2 1.4 Physical Description...3 Chapter
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
How To Run An Nport I5000A Device Server
NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Broadband Phone Gateway BPG510 Technical Users Guide
Broadband Phone Gateway BPG510 Technical Users Guide (Firmware version 0.14.1 and later) Revision 1.0 2006, 8x8 Inc. Table of Contents About your Broadband Phone Gateway (BPG510)... 4 Opening the BPG510's
EZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
How To Check If Your Router Is Working Properly
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Dual Band Wireless-N Router WNDR3300. You can access these features by selecting the
Wifi Pan/Tilt IP Camera User Manual
Wifi Pan/Tilt IP Camera User Manual Rev. 3.0 Software Version 3.00 May. 25 th.2009 Table of Contents 1. PRODUCT VIEWS...3 1.1. PRONT PANEL...3 1.2. BACK PANEL...3 1.3. ACCESSORIES...4 2. SETUP AND STARTUP...5
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
UIP1868P User Interface Guide
UIP1868P User Interface Guide (Firmware version 0.13.4 and later) V1.1 Monday, July 8, 2005 Table of Contents Opening the UIP1868P's Configuration Utility... 3 Connecting to Your Broadband Modem... 4 Setting
IntesisBox Modbus Server - Mitsubishi Electric G50
IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Operation Manual of EX-9132C-2. Serial to TCP/IP Converter
Operation Manual of EX-9132C-2 Serial to TCP/IP Converter Version 1.2.1 20th May 2013 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 6 Product Specifications
Users manual. TCW181B-CM_R1 Page 1
Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
GPS NTP TIME SERVER Rack Version V2
GPS NTP TIME SERVER Rack Version V2 Description: Server is dedicated to synchronize network devices local time/date to Universal Time (UTC) Devices synchronizing own local time through the NTP V3 protocol.
Contents. Section A Networking Basics... 1. 1 Learning the Basics... 3. Section B Wired Ethernet Networking... 17
Contents Section A Networking Basics...................................... 1 1 Learning the Basics............................................. 3 Selecting a network connection........................................
Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide
Prestige 324 Intelligent Broadband Sharing Gateway Version V3.61(JF.0) May 2004 Quick Start Guide 1 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100
H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration
H0/H2/H4 -ECOM100 DHCP & HTML 6 H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML 6-2 H0/H2/H4 -ECOM100 DHCP DHCP Issues The H0/H2/H4--ECOM100 is configured at the factory
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under
Serial over Ethernet Device Server. User s Manual
Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw [email protected] Serial over Ethernet
4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items
TSX ETY 110 Module 8
Module 8 Introduction Subject of this chapter What s in this Chapter? This chapter describes the implementation of a TSX ETY 110 module. This chapter contains the following sections: Section Topic Page
Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Operation Manual of EX9132C-RS485. Serial to TCP/IP Converter
Operation Manual of EX9132C-RS485 Serial to TCP/IP Converter Version 1.0 27th May 2014 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Product Features 7 Product Specifications
Nokia Siemens Networks. CPEi-lte 7212. User Manual
Nokia Siemens Networks CPEi-lte 7212 User Manual Contents Chapter 1: CPEi-lte 7212 User Guide Overview... 1-1 Powerful Features in a Single Unit... 1-2 Front of the CPEi-lte 7212... 1-2 Back of the CPEi-lte
Using IDENT M System T with Modbus/TCP
Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide
Prestige 324 Intelligent Broadband Sharing Gateway Version 3.60 January 2003 Quick Start Guide 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100 Mbps
DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.
DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS REV 04.11 LOCAL AREA NETWORK (LAN) CONNECTION Ethernet Connection: An Ethernet Cable, or wireless connection must
your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Configuring Installing
your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Installing Configuring Contents 1 Introduction...................................................... 1 Features...........................................................
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as