1 Network Automation Solutions

2 Answers to demands The current demographic growth and the continuous industrial development pose challenges for the current way of producing and distributing electricity. Energy suppliers must therefore produce more energy while optimizing distribution networks to satisfy their customers requirements of high quality service. Global solutions are necessary to reduce the duration and frequency of electricity outages. Ensto Network Automation solutions offer answers to these demands. Fast fault detection, automatic isolation of faulty network sections and remote network reconfiguration are essential part of network automation solutions. Electricity distribution performance index To evaluate their performance, electrical utility companies follow specific international indicators: SAIDI (System Average Interruption Duration Index) which measures the average cumulated power outage duration in minutes and per customer. SAIFI (System Average Interruption Frequency Index) which measures the average number of power outages per customer. Ensto s solutions are adaptable for every network globally to optimize electricity distribution.

3 Network Automation Ensto products overview Overhead line network Overhead line network

4 Network Automation Ensto products overview Switch disconnectors Auto-reclosers IA2T AUGUSTE ERGOSWITCH SMARTCLOSER Rated voltage: 24/36 kv Rated current: 400 A Breaking capacity: 100 A max. Rated voltage: 24/36 kv Rated current: 630 A Breaking capacity: 630 A Rated voltage: 12/24 kv Rated current: 630 A Breaking capacity: 630 A Rated voltage: 38 kv Rated current: 630 A Breaking capacity: 12,5 ka Quenching media Air SF6 Vacuum Isolation media Air SF6 Epoxy Sectionalizing function Can be configured as a sectionalizer. Can automatically isolate the faulty section of the network after a programmed number of openings of an auto-recloser located upstream. Main features IA2T Air Break Switch responds to the service quality requirements in terms of reducing outage duration and frequency. Air Break Switch is installed on the main line after a feeder. It allows feeders to be divided into shorter sections to distribute loads or isolate a section of the network in case of outage. Remote control enables necessary operations for service continuity remotely. These load break switches are used in all types of overhead distribution networks in rural and suburban areas. Devices are available as manually or remotely controlled versions. They are designed to be easily integrated in remotely controlled SCADA systems. Modular design of the load break switches makes them adaptable to network constraints and different operating modes. Auguste and Ergoswitch load break switches suit many requirements: ensure service continuity fast and easy installation safe and reliable operation improve network cost-effectiveness Ensto Smartcloser is an intelligent autonomous device for detecting overcurrents, interrupting fault currents and re-energizing the line by automatic reclosing. If a fault is permanent the faulty section will be automatically isolated from the healthy part of the network. Ensto Smartcloser: long lifetime high level of electrical endurance convenient for all type of networks well suited for networks that require high breaking capacity extremely reliable safe for installers and end-users Conforms to international standard CEI Conform to international standards CEI and CEI Conforms to international standard CEI

5 Network Automation Ensto products overview Switchgear controllers Controller for Air Break Switch ( ) 1 Controller for Load Break Switch ( ) ITI-A Controller for Auto-recloser ( ) Controller for Ring Main Unit ITI-S Type of network Switchgear compatibility Overhead line Underground cable 1 IA2T Air Break Switch 1 Auguste or Ergoswitch LBS 1 Smartcloser Auto-recloser Up to 8 switches Measure Current, voltage, power and power supply Current, voltage and power supply Fault detection Overcurrent Directional (ERDF configuration) Overcurrent ANSI 50, 51 Overcurrent Directional (ERDF configuration) Protocols IEC IEC Modbus RTU DNP3 HNZ (ERDF specification) Communication Digital or analog radio Dedicated Lines GSM GPRS Public Switch Telephone Network (PSTN) Ethernet External RTU In line with international standards Conforms to HN 64-S-44 specification In line with international standards Conforms to HN 64-S-44 specification

6 Network Automation Ensto products overview Distributed generation Fault Passage Indicators Operating Data Exchange System DEIE Overcurrent LYNX 2400 Directional LYNX 3400 Type of network Main features Underground cable DEIE box is a control unit which manages the remote control and monitoring of decentralized generating facilities e.g. wind turbines, power plants etc. DEIE box allows information exchange and commands between network manager and independent producer. It is connected to the control center (SCA- DA) via Public Switch Telephone Network (PSTN) or GPRS. Information is transmitted with communication protocols: HNZ (ERDF specification) IEC Type of network Neutral system Underground cable Resistor linked to earth Rated voltages of the network Power Supplies Main features 15, 20 or 36 kv 50/60Hz Underground cable Compensated with Peterson coil Autonomous (supercapacitor or lithium batteries) or supplied by a low voltage network with battery backup power. LYNX 2400 accurately locates faults occurring on medium voltage networks with resistive neutral. LYNX 2400 includes a main box, an external indicator light and 3 opening core sensors that are placed on the cables of the line being monitored. LYNX 3400 accurately locates faults occurring on medium voltage networks with a compensated neutral system. LYNX 3400 includes a main box, an external indicator light, 3 opening core current sensors and 3 PPACS voltage sensors. Conform to HN 64-S-59 specification Conforms to HN 45-S-50 specification Conform to HN 45-S-51 specification

7 SAIFI NETWORK PERFORMANCE UNDERGROUND CURRENT SCADA SWITCHES SERVICE EFFICIENCY PRODUCTION ENERGY MEASURE OVERHEAD QUALITY ELECTRICITY AUTOMATION VOLTAGE RELIABILITY MV MANAGEMENT SOLUTIONS OPTIMIZATION SAIDI DISTRIBUTION CUSTOMER LINES DATA GAIN SATISFACTION REACTIVITY Solutions to optimize medium voltage distribution Improve network infrastructure shorter sections redundant network reliable components Improve network management by adding fault passage indicators (FPI) by adding automated switchgear equipped with Intelligent Electronic Devices (IED) that provide advanced protection, control, power quality recording and measurement SCADA system integration Network automation improves the quality and continuity of service with affordable investments compared to non-optimized network. Network automation means significantly less repair costs, less interruptions to power lines due to maintenance work and more reliable electricity distribution.

8 Ensto Novexia 210, rue Léon Jouhaux - BP FR Villefranche-sur-Saône cedex Tel: + 33 (0) Fax: + 33 (0) UN46/ENG/11/2016

An Alternative Approach to Improving SAIDI and SAIFI Indicators

An Alternative Approach to Improving SAIDI and SAIFI Indicators An Alternative Approach to Improving SAIDI and SAIFI Indicators Philippe Deschamps - Schneider Electric Industries - France Jean-Christophe Orsini - Schneider Electric Industries - France Kaare Seest Rasmussen

More information

Power products and systems. Intelligent solutions for power distribution Zone concept

Power products and systems. Intelligent solutions for power distribution Zone concept Power products and systems Intelligent solutions for power distribution Zone concept Securing continuous power supply ABB is one of the world's leading power and automation technology companies whose products,

More information

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic

More information

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions Secure your electrical network The Safety Solution for Healthcare Institutions Fast Secure : the solution for fault isolation and electrical network restoration in less than 500 ms 03 A Real Time System

More information

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage

More information

Nu-Lec Training Modules

Nu-Lec Training Modules PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features

More information

Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms

Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms The future of Wind Farms As offshore wind farms move towards deploying higher capacity

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

Distribution Automation / Smart Grid. Kevin Whitten

Distribution Automation / Smart Grid. Kevin Whitten Distribution Automation / Smart Grid Kevin Whitten Main Overview Distribution Reliability Distribution Automation Smart Grid Distribution Reliability Distribution Reliability - Overview Introduction to

More information

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver www.siemens.com/fusesaver Siemens Fusesaver Highest availability and cost savings for your MV distribution network Answers for infrastructure and cities. 2 In high demand: An intelligent solution Improving

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

MV NETWORK REMOTE MONITORING AND CONTROL EXPERIENCES FROM DISTRIBUTION UTILITIES IN CROATIA

MV NETWORK REMOTE MONITORING AND CONTROL EXPERIENCES FROM DISTRIBUTION UTILITIES IN CROATIA MV NETWORK REMOTE MONITORING AND CONTROL EXPERIENCES FROM DISTRIBUTION UTILITIES IN CROATIA Darijo RUNJIC, Goran LECI Koncar-Power Plant And Electric Traction Engineering Inc, Croatia darijo.runjic@koncar-ket.hr;

More information

25 Distribution System Automation

25 Distribution System Automation Chap25 exe 21/06/02 8:30 Page 442 Distribution System Automation Introduction 25.1 Factors influencing the application of automation to distribution networks 25.2 Primary distribution system automation

More information

A Case Study: How a Utility Automated and Integrated Data/Control for 4000 Pole-Top Switches and Protection Relays, and Reduced its SAIDI

A Case Study: How a Utility Automated and Integrated Data/Control for 4000 Pole-Top Switches and Protection Relays, and Reduced its SAIDI A Case Study: How a Utility Automated and Integrated Data/Control for 4000 Pole-Top Switches and Protection Relays, and Reduced its SAIDI Hervé Delmas, Eng. - Hydro-Quebec Patrick Cossette, Eng. - Cooper

More information

Chapter 1. Network Structures

Chapter 1. Network Structures Chapter 1 Network Structures Definition Standard IEC 60038 defines voltage ratings as follows: Low voltage (): for a phase-to-phase voltage of between 100 V and 1,000 V, the standard ratings are: 400 V

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor

More information

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz) 24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690

More information

SCADA Systems Automate Electrical Distribution

SCADA Systems Automate Electrical Distribution SCADA Systems Automate Electrical Distribution PC-based supervisory control and data acquisition systems increase uptime, cut costs and improve utilization. A White Paper from InduSoft Fabio Terezinho

More information

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia From INTEGRIS a solution architecture for energy smart grids Jean Wild - Schneider Electric

More information

Relion. Power system protection and automation reference Fast substation busbar protection with IEC 61850 and GOOSE

Relion. Power system protection and automation reference Fast substation busbar protection with IEC 61850 and GOOSE Relion Power system protection and automation reference Fast substation busbar protection with IEC 61850 and GOOSE Fast substation busbar protection with IEC 61850 and GOOSE Falu Elnät AB applies new power

More information

Natural Gas Well Automation using Kingfisher RTU Products

Natural Gas Well Automation using Kingfisher RTU Products Natural Gas Well Automation using Kingfisher RTU Products Introduction Semaphore s Kingfisher RTU products have been applied to well site installations throughout the world. The product family includes

More information

Earth Fault Detection Basics in Theory

Earth Fault Detection Basics in Theory Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star

More information

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics

More information

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850 Relion Power system protection and automation reference Extending substation life cycle with IEC 61850 Extending substation life cycle with IEC 61850 A step-by-step power system retrofit approach for optimizing

More information

Siemens ENEAS solutions for substation automation and protection

Siemens ENEAS solutions for substation automation and protection Siemens ENEAS solutions for substation automation and protection System solutions for energy automation Answers for energy. An integrated approach for the entire spectrum of energy automation New challenges

More information

ABB PSPS Erich Steinmann; Generator control-2013

ABB PSPS Erich Steinmann; Generator control-2013 ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM HELLENIC ELECTRICITY DISTRIBUTION NETWORK OPERATOR S.A. NOTICE OF CALL FOR TENDERS No ND-xxx PROJECT: Pilot Telemetering and Management System for the Electric Power Supply Demand by Residential and Small

More information

DISTRIBUTION RELIABILITY USING RECLOSERS AND SECTIONALISERS

DISTRIBUTION RELIABILITY USING RECLOSERS AND SECTIONALISERS ABB DISTIBUTION ELIABILITY USING ECLOSES AND SECTIONALISES obert E. Goodin Chief Engineer ABB Inc. Lake Mary, FL Timothy S. Fahey, PE Sr. Application Engineer ABB Inc. aleigh, NC Andrew Hanson, PE Executive

More information

ADMS(Advanced Distribution Management System ) in Smart Grid

ADMS(Advanced Distribution Management System ) in Smart Grid ADMS(Advanced Distribution Management System ) in Smart Grid 柯 佾 寬 博 士 Yi-Kuan Ke, Ph.D. 2014/03/28 Smart Grid Solution Smart Grid Solution Overview Smart Grid Solutions Smart Network Operation - Distribution

More information

Efficient remote access to machines and plants with SIMATIC

Efficient remote access to machines and plants with SIMATIC Efficient remote access to machines and plants with SIMATIC Telecontrol and teleservice solutions modular, flexible and secure SIMATIC NET siemens.com/industrial-remote-access Industrial remote access

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,

More information

F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China

F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China ELECTRIC POWER DISTRIBUTION SYSTEMS F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China Keywords: Distribution system planning, Load characteristics, Subtransmission Lines, Distribution

More information

What will MV switchgear look like in the future? by Jean-Marc Biasse

What will MV switchgear look like in the future? by Jean-Marc Biasse What will MV switchgear look like in the future? by Jean-Marc Biasse Table of contents Introduction... 2 Brief history of the technologies used in medium voltage switchgear and control gear... 4 Evolution

More information

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact Authors Carl Ejnar Sölver, ABB High Voltage Products Rasmus Larsson, ABB High Voltage Products 2 ABB ABB

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

Monitoring Underground Power Networks

Monitoring Underground Power Networks Monitoring Underground Power Networks By Mark Stiles Merve Cankaya ABSTRACT Underground electric distribution systems are common in large cities throughout the United States. Power usage for the entire

More information

How To Choose A Transformer

How To Choose A Transformer Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV

More information

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A Roberts, T Berry, W D Wilson Schneider Electric Ltd, UK SYNOPSIS This paper describes the features of a modern Distribution

More information

Investor day. November 17, 2010. Energy business Michel Crochon Executive Vice President

Investor day. November 17, 2010. Energy business Michel Crochon Executive Vice President Investor day November 17, 2010 Energy business Michel Crochon Executive Vice President We built a global leadership in medium voltage and grid automation with Areva Distribution MV switchgears & systems

More information

Arc Terminator Active Arc-Resistant Switchgear

Arc Terminator Active Arc-Resistant Switchgear Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers

More information

Basics in Energy Information (& Communication) Systems Summary Substation Automation

Basics in Energy Information (& Communication) Systems Summary Substation Automation Basics in Energy Information (& Communication) Systems Summary Substation Automation Dr. Johann Pohany, xxxx x xxx xxx xx Substation Integration and Automation Levels Integrated utility business operation

More information

UFES Active protection for switchgear

UFES Active protection for switchgear Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document

More information

David Payne, P.E. Associate Director February 18, 2014

David Payne, P.E. Associate Director February 18, 2014 David Payne, P.E. Associate Director February 18, 2014 Overview of Texas A&M University State's first public institution of higher education, was opened on Oct. 4, 1876 as the Agricultural and Mechanical

More information

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy

More information

EssPro Energy Storage Grid Substation The power to control energy

EssPro Energy Storage Grid Substation The power to control energy EssPro Energy Storage Grid Substation The power to control energy EssPro Grid gives you the power to control energy helping to keep smart grids in balance Maximizing the value and performance of energy

More information

About T&D Europe : The association

About T&D Europe : The association G. onizza Electra: Doing Business with Energy G. onizza Electra: Doing Business with Energy Electra Doing Business with Energy Efficiency Thursday 15. October 2009, Ljubljana (SI) Electra conclusions in

More information

Market Growth and New Regulations Demand Network Modernization

Market Growth and New Regulations Demand Network Modernization CASE ESB NETWORKS: POLE TOP COMMUNICATION INCREASES EFFICIENCY IN IRELAND Viola s solution for remotely operating pole-top reclosers and switches increases reliability, cuts operating costs and helps to

More information

Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. sergio.fujii@areva-td.com. ethan.boardman@areva-td.com

Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. sergio.fujii@areva-td.com. ethan.boardman@areva-td.com Agenda do Mini-Curso Sérgio Yoshio Fujii sergio.fujii@areva-td.com Ethan Boardman ethan.boardman@areva-td.com Agenda do Mini-Curso Sistemas de Distribuição (DMS) Characteristics of Distribution Network

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

BL20A0501 Electricity distribution technology. Introduction Jarmo Partanen

BL20A0501 Electricity distribution technology. Introduction Jarmo Partanen BL20A0501 Electricity distribution technology Introduction Jarmo Partanen Introduction to ED Prof. Jarmo Partanen, D.Sc Jukka Lassila Topics of lectures Introduction to Electricity Distribution, 27.10

More information

NEW. EVEN MORE data acquisition and test stand automation

NEW. EVEN MORE data acquisition and test stand automation NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware

More information

QUALITY CONTROL Prepared: V. van Gastel / team TenneT Reviewed: M. Müller 23.06.2015 Approved: F. Wester 23.06.2015 1. BACKGROUND MATERIAL...

QUALITY CONTROL Prepared: V. van Gastel / team TenneT Reviewed: M. Müller 23.06.2015 Approved: F. Wester 23.06.2015 1. BACKGROUND MATERIAL... POSITION PAPER STAKE HOLDER CONSULTATION PROCESS OFFSHORE GRID NL Type: Position paper Work stream Technical Topic: T.2 Number of J-Tubes Filename ONL 15-060-T2_ J tubes_ bays_pp_v2 Version 3 - Public

More information

Underground vs. Overhead Transmission and Distribution

Underground vs. Overhead Transmission and Distribution electric power engineering Underground vs. Overhead Transmission and Distribution Your Power System Specialists June 9, 2009 1 NATIONAL TRENDS Municipalities have passed laws requiring new distribution

More information

Monitoring & Control of Small-scale Renewable Energy Sources

Monitoring & Control of Small-scale Renewable Energy Sources Small Scale Renewable Energy Sources and Energy Saving: 6-17 th July 2009 Monitoring & Control of Small-scale Renewable Energy Sources Dr G A Taylor Brunel Institute of Power Systems Brunel University,

More information

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker

More information

Substation Automation and Smart Grid

Substation Automation and Smart Grid GE Energy Substation Automation and Smart Grid John D. McDonald, P.E. GM, T&D Marketing IEEE PES Past President IEEE Division VII Director IEEE Fellow The Smart Grid POWERING POTENTIA L Current Situation

More information

IEC 61850: Communication Networks and Systems in Substations

IEC 61850: Communication Networks and Systems in Substations IEC 61850: Communication Networks and Systems in Substations Sistemi e strumenti per l'automazione, A. Flammini, AA2011-2012 Background I: Power Grid Sistemi e strumenti per l'automazione A. Flammini,

More information

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

SF 6 Gas Insulated Switchgear Type SDF for 170 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment

More information

Medium voltage arc flash eliminator units VAM 3ED,

Medium voltage arc flash eliminator units VAM 3ED, Medium voltage arc flash eliminator units VAM 3ED,, Medium voltage arc flash eliminator units Medium voltage arc flash eliminator units The new innovative arc eliminator VAM 3ED is an extremely fast acting

More information

GSM ATT Modules Simply effective remote control

GSM ATT Modules Simply effective remote control GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential

More information

The Industrial Wireless Book - Articles TECHNICAL ARTICLE: USING GPRS TO CONNECT SMALL, OUTLYING STATIONS

The Industrial Wireless Book - Articles TECHNICAL ARTICLE: USING GPRS TO CONNECT SMALL, OUTLYING STATIONS Page 1 of 6 Print this Page Close this Window TECHNICAL ARTICLE: USING GPRS TO CONNECT SMALL, OUTLYING STATIONS Process monitoring and control for electricity distribution grids until now has been available

More information

ABB Fuses Competitive Advantages

ABB Fuses Competitive Advantages GPMM Tomasz Komalski 2009 ABB Fuses Competitive Advantages May 14, 2009 Slide 1 Basic comments ABB is a global manufacturer of both current limiting and expulsion (non-current limiting) fuses for medium

More information

Minimizing Impact of Electric Utility Outages with Backup Generation

Minimizing Impact of Electric Utility Outages with Backup Generation Minimizing Impact of Electric Utility Outages with Backup Generation Introduction of the Speaker Michael Dempsey, PE Senior Electrical Engineer Carter & Burgess, Inc. Energy & Power Solutions Facility

More information

2012 Smart Grid R&D Program Peer Review Meeting Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System

2012 Smart Grid R&D Program Peer Review Meeting Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System 2012 Smart Grid R&D Program Peer Review Meeting Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System James Stoupis ABB Inc., US Corporate Research Center

More information

ABB central inverters PVS800 100 to 1000 kw

ABB central inverters PVS800 100 to 1000 kw Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1

More information

GENe Software Suite. GENe-at-a-glance. GE Energy Digital Energy

GENe Software Suite. GENe-at-a-glance. GE Energy Digital Energy GE Energy Digital Energy GENe Software Suite Today s utilities have complex requirements that need sophisticated solutions. GE Energy s GENe provides these solutions. Using the latest advances in technology,

More information

ECE 586b Course Project Report. Auto-Reclosing

ECE 586b Course Project Report. Auto-Reclosing ECE 586b Course Project Report Auto-Reclosing Srichand Injeti May 5, 2008 Department Of Electrical and computer Engineering University Of Western Ontario, London Ontario Table of contents 1. Introduction...1

More information

Industrial IT for Substation Automation & Protection

Industrial IT for Substation Automation & Protection Industrial IT for Substation Automation & Protection Exploit the potential of ABB substation automation Improve your performance In view of the increasingly competitive arena where power providers are

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective

Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective India Core Events 2008 September 24 th 2008 1 Background Stability & Reliability Data Storage Communication

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply. www.siemens.com/siestorage

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply. www.siemens.com/siestorage Totally Integrated Power SIESTORAGE The modular energy storage system for a reliable power supply www.siemens.com/siestorage Totally Integrated Power (TIP) We bring power to the point. Our products, systems,

More information

Everything you need for protection scheme testing

Everything you need for protection scheme testing Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full

More information

EssPro Grid Battery energy storage systems The power to control energy

EssPro Grid Battery energy storage systems The power to control energy EssPro Grid Battery energy storage systems The power to control energy EssPro Grid gives you the power to control energy helping to keep smart grids in balance Maximizing the value and performance of energy

More information

30 ms High Speed Transfer System (HSTS) Product Description

30 ms High Speed Transfer System (HSTS) Product Description 30 ms High Speed Transfer System (HSTS) Product Description 2 30 ms High Speed Transfer System (HSTS) Product Description Content Page 1 General 5 1.1 Description of the 30 ms high speed transfer system

More information

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION 1 EFFICIENT ELECTRICAL ENERGY TRANSMISSION

More information

Venteea A Smart Grid demonstrator for the DRES integration on the MV distribution networks. www.venteea.fr/en/

Venteea A Smart Grid demonstrator for the DRES integration on the MV distribution networks. www.venteea.fr/en/ Venteea A Smart Grid demonstrator for the DRES integration on the MV distribution networks www.venteea.fr/en/ Lille, le 26 novembre 2015 Agenda Project overarching objectives The consortium The added value

More information

Advantages of Fixed Circuit Breaker Switchgear

Advantages of Fixed Circuit Breaker Switchgear Advantages of Fixed Circuit Breaker Switchgear by Lionel Mackay, EDF Energy, and Mike Adams, Schneider Electric Ltd Introduction The purpose of this paper is to review the advantages of fixed circuit breaker

More information

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Single and three phase modular Automatic Transfer Switch from 40 to 160 A NEW SINGLE PHASE Single and three phase modular Automatic Transfer Switch from 40 to 160 A SWITCH TO INNOVATION SOCOMEC: intelligent changeover systems As a worldwide leading company in changeover power

More information

Application of Four-Pole Circuit Breakers within Data Centers

Application of Four-Pole Circuit Breakers within Data Centers Application of Four-Pole Circuit Breakers within Data Centers December 2013/AT324 by Frank Waterer, Fellow Engineer, Schneider Electric Engineering Services Make the most of your energy SM Revision #1

More information

Distribution System Automation

Distribution System Automation ES 586b Course Project Report Distribution System Automation Prepared By Palak Parikh Ph.D. Scholar, Electrical and Computer Engineering Department, University of Western Ontario. Abstract Electric power

More information

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management My2B GSM/GPRS Datalogger with Alarm Management 100% Made & Designed in Italy My2B GSM/GPRS Datalogger with Alarm Management MY2B ( Standard / Datalogger) is a GSM / GPRS telecontrol unit for home & building

More information

Low Cost Automatic Transmission Line Sectionalizing

Low Cost Automatic Transmission Line Sectionalizing Low Cost Automatic Transmission Line Sectionalizing The Ohio State University Distinction Project Autumn 2009 Andrew Dulmage EXECUTIVE SUMMARY This report contains detailed information about the design,

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

For Utility Operations

For Utility Operations For Utility Operations Provided For: SCAMPS 2014 Annual Meeting Presented By: Michael E. Jenkins, PE What Are We Talking About? Simply, Preparing A Clear Picture Of Where And How The Utility Is Headed

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

REPLACEMENT PLANNING STRATEGY TO OPTIMIZE LIFE CYCLE PROFIT. N-7034 Trondheim Willy Hanssen, Trondheim Energiverk Nett AS

REPLACEMENT PLANNING STRATEGY TO OPTIMIZE LIFE CYCLE PROFIT. N-7034 Trondheim Willy Hanssen, Trondheim Energiverk Nett AS REPLACEMENT PLANNING STRATEGY TO OPTIMIZE LIFE CYCLE PROFIT Arnt Ove Eggen, Eivind Solvang Jan A. Foosnæs, Nord-Trøndelag Elektrisitetsverk SINTEF Energy Research Kjell Harald Hansen, Troms Kraft Nett

More information

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Victor Lee Commercial Marketing Manager SEA Eaton Oil & Gas Solution Tech Day 2013 Eaton. All Rights Reserved. Eaton is a leading

More information

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear rated voltage 15, 27 and 38 kv rated current 630 A Outdoor circuit breakers GVR Recloser GVR switchgear brings the reliability of modern

More information

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy. s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage

More information

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER. Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the

More information

Multilin Intelligent Line Monitoring System

Multilin Intelligent Line Monitoring System GE Digital Energy Multilin Intelligent Line Monitoring System Delivering actionable intelligence for improved reliability and efficiency Distribution utilities are faced with regulatory requirements to

More information

Trip circuit supervision relay. Type RXTCS

Trip circuit supervision relay. Type RXTCS Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

DMS - Breakthrough Technology for the Smart Grid

DMS - Breakthrough Technology for the Smart Grid DMS - Breakthrough Technology for the Smart Grid The emerging smart grid is expected to address many of the current challenges in the electrical power industry. It is expected to make the electric grid

More information

Deep Dive on Microgrid Technologies

Deep Dive on Microgrid Technologies March 2015 Deep Dive on Microgrid Technologies 2 3 7 7 share: In the wake of Superstorm Sandy, a microgrid kept the lights on for more than for the more than 60,000 residents of Co-Op City in the northeastern

More information