1 aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding ir Preparation Units Parker-Watts General Line FRL, Hi-Flow FRL & esiccant ryers atalog 7-

2 atalog 7- Warnings, Offer of Sale ir Preparation Units! UTION: Polycarbonate bowls, being transparent and tough, are ideal for use with Filters and Lubricators. They are suitable for use in normal industrial environments, but should not be located in areas where they could be subjected to direct sunlight, an impact blow, nor temperatures outside of the rated range. s with most plastics, some chemicals can cause damage. Polycarbonate bowls should not be exposed to chlorinated hydro-carbons, ketones, esters and certain alcohols. They should not be used in air systems where compressors are lubricated with fire-resistant fluids such as phosphate ester and di-ester types. Metal bowls are recommended where ambient and/or media conditions are not compatible with polycarbonate bowls. Metal bowls resist the action of most such solvents, but should not be used where strong acids or bases are present or in salt laden atmospheres. onsult the factory for specific recommendations where these conditions exist. TO LN POLYRONT OWLS US MIL SOP N WTR ONLY! O NOT use cleansing agents such as acetone, benzene, carbon tetrachloride, gasoline, toluene, etc., which are damaging to this plastic. Metal bowl guards are recommended for all applications.! UTION: RGULTOR PRSSUR JUSTMNT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. WRNING FILUR OR IMPROPR SLTION OR IMPROPR US OF TH PROUTS N/OR SYSTMS SRI HRIN OR RLT ITMS N US TH, PRSONL INJURY N PROPRTY MG. This document and other information from Parker Hannifin orporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application including consequences of any failure, and review the information concerning the product or system in the current product catalog. ue to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin orporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin orporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled Offer of Sale. opyright -, Parker Hannifin orporation. ll Rights Reserved.! Parker Hannifin orporation

3 atalog 7- Table of ontents ir Preparation Units General Information - Particulate & oalescing Filters...- Particulate Filters Minature Particulate Filters...-7 ompact Particulate Filters Standard Particulate Filters...- Hi-Flow Particulate Filters...-9 oalescing Filters Miniature oalescing Filters...- ompact oalescing Filters...- Standard oalescing Filters...-7 Hi-Flow oalescing Filters...8- ulk Liquid Separators...- esiccant ryers...-7 General Information - Regulators Regulators Miniature Regulators...-9 conomy Regulators...- ompact Regulators...- Standard Regulators...-7 Hi-Flow Regulators...8- Pilot Operated Regulators...-7 General Information - Filter / Regulators Filter / Regulators Miniature Filter / Regulators ompact Filter / Regulators Standard Filter / Regulators General Information - Lubricators Lubricators Miniature Mist Lubricators ompact Micro-Mist Lubricators Standard Micro-Mist Lubricators Standard Mist Lubricators Hi-Flow Mist Lubricators ombinations Miniature ombinations ompact & Standard ombinations...- Safety Guide...-7 Offer of Sale... 8 Parker Hannifin orporation

4 atalog 7- General Information ir Preparation Units Particulate and oalescing Filters Particulate and oalescing Filters Filtration The average -hp compressor handles four million cubic inches of air per hour. This air can contain billions of contaminating particles. t high concentration and high speed, these particles can be extremely harmful. They block orifices, erode components, and clog clearances between moving parts. In addition, when ambient air is drawn into a compressor, it can, depending on weather conditions, have relative humidity up to percent. s air is compressed and cooled, some water vapor condenses out as free water, and even with a compressor aftercooler, some moisture is swept downstream into the air system. This may result in rusted pneumatic tools and components, contaminated lubricants, and frozen air lines during low temperature periods. Other types of foreign matter in air lines include: impurities generated within the air line, such as wear particles, pipe scale and rust; construction and assembly debris; and contaminants introduced into the air system during maintenance or through leakage passages. ll these contaminants, which are of a size to cause air stream problems, should be removed by the filter. Water vapor, which is a gas, is not a contaminant in pneumatic systems until it condenses. How to Select the Proper Filter Filter element rating is the prime selection criterion. This rating must match the requirements of all downstream components. Next, the flow capacity and pressure rating of the filter should be considered. Finally, port size should match system piping to avoid unnecessary pressure drops through restricting adapters. owl material and the type of drain for the application are other choices to be made. The first step in choosing a filter is to determine the filtration requirements of the most critical components used in that system. ontamination particle size is measured in micrometers. micrometer is one millionth of a meter or.9 inches. Frequently, micrometer is abbreviated as micron or symbolized by the Greek letter µ. Particle-removing filter elements are rated according to the particle size they will trap. For most industrial applications, filter elements rated at microns are adequate. When necessary, filtration as low as microns or finer can be provided. Remember, however, that finer filtration increases the pressure drop through the element. s micron size rating varies, so does the size and type of filter. Most oils entrained in a compressed air stream are in the form of tiny mist or aerosol droplets which can pass through a standard industrial filter element. If it is necessary to remove these aerosols, an oil-removal type coalescing filter can be used. The sub-micron oil particles which escape an oil-removal filter should have no detrimental effect on industrial pneumatic components. ut if these particles must be removed for applications such as spray painting, a coalescing type element should be used. The inexact nominal filter element rating indicates that most particles that size or larger will be trapped. The absolute rating indicates that all particles that size or larger will be trapped. Filter onstruction Most pneumatic filters consist of two basic elements: a die-cast body, into which the inlet and outlet piping is connected, and a sealed removable bowl which contains collected contaminants. The bowl is fitted with a drain mechanism to remove liquids before they rise to the baffle level. The drain system usually operates while the filter is under pressure, but the unit must be exhausted to remove the bowl for cleaning and element service. The piping need not be disturbed Generally a transparent bowl is the most convenient because it provides easy visual inspection of the sump level. However, hostile environment, higher pressure, or higher temperature may require a metal bowl for safety. The most common plastic used for bowls is polycarbonate. This material performs satisfactorily for air pressures below PSIG and temperatures between and F. Parker offers polyethylene bowl guards for added safety. s the pressure or temperature requirement increases, you may have to specify a metal bowl with sight gauge. For extreme conditions, it is recommended that the sight gauge be eliminated. (Please refer to the individual model descriptions for specifications on bowls.) Thus, the environment determines the choice of bowl. Polycarbonates offer great strength and visibility, but can be attacked by certain chemicals. Metal bowls offer the highest pressure and temperature rating, and provide superior protection when installed in an environment containing chemicals that are incompatible with polycarbonate. Filter Operation When pressurized air enters a typical filter body. The curved inlet and deflector direct the incoming air in a downward whirling pattern. entrifugal force hurls the larger solid and liquid water particles outward where they collect on the inner surface of the filter bowl. The particles spiral down past a baffle into a quiet chamber. The baffle prevents turbulent air in the upper bowl from re-entraining liquid contaminants and carrying them downstream. Then the dry, cleaner air follows a convoluted path through the filter element, where finer solid particles are filtered out. Finally, filtered air passes up the center of the element and out the discharge port. Parker Hannifin orporation

5 atalog 7- General Information ir Preparation Units Particulate and oalescing Filters Particulate and oalescing Filters Warning! The plastic material used to manufacture the plastic bowls, and the sight gauge on metal bowls, may be attacked by certain chemicals. o not use this filter on systems with air supplied by a compressor lubricated with synthetic oils or oils containing phosphate esters or chlorinated hydrocarbons. These oils can carry over into the air lines and chemically attack and possibly rupture the bowl or sight gauge. lso, do not expose the bowl or sight gauge to materials such as carbon tetrachloride, trichlorethylene, acetone, paint thinner, cleaning fluids, or other harmful materials, for they too will cause the plastic to craze and/or rupture. For use in environments where these, or any, chemicals may be present, consult the factory for approval. oalescing Filters These high-efficiency filters operate on a somewhat different principle than particulate air filters. The key difference is in the element, where a fiber network is narrowly spaced to trap smaller contaminants. The special fibers hold any liquid particle which contacts them. Pre-filtered ( particulate filter must be used prior to a coalescing filter) air enters the cylindrical element at the center. s it flows through the element, particles are captured by three different mechanisms: direct interception as particles impinge on the fibers; inertial impaction as particles are thrown against fibers by the turbulent air stream; and diffusion as smaller particles vibrate with rownian movement to collide with fibers and other particles. s a result, coalescing elements can capture particles smaller than the nominal size of the flow passages through the element. ollected liquid migrates to the crossing points of the fibers where larger drops form or coalesce. Pressure differential through the element then forces these drops to the downstream surface of the element where they gravitate downward to the sump. The filtered air then exits through the outlet port. It is very important that the air be pre-filtered, as larger contaminants tend to block the passages between fibers, reducing the efficiency of the coalescing element. ody O-Ring Flange Ring eflector Shroud Retaining Rod Filter lement Pressure Plate affle ssembly Sight Gauge owl ssembly rain Particulate Filters Pop-Up Indicator Plug ody Flange Ring O-Ring Retaining Rod Filter lement Sight Gauge affle ssembly owl ssembly utomatic rain oalescing Filters Parker Hannifin orporation

6 atalog 7- Miniature F Series Miniature Filters /8 & / Inch Ports F Filters Miniature Features Twist rain utomatic rain xcellent water removal efficiency Unique deflector plate that creates swirling of the air stream ensuring maximum water and dirt separation asily disassembled for servicing without the use of tools Micron element standard Interchangable twist and utomatic Pulse rain automatic pulse drains High flow: /8" SFM /" SFM ccepts /8" Tubing istance Required F To Remove ll owls Regardless Of rain Option Port NPT Size Twist rain utomatic Pulse rain Poly owl /8" F* F* /" F* F* Metal owl without Sight Gauge /8" F* F7* /" F* F7* Standard part numbers shown bold. For other models refer to ordering information below. For polycarbonate bowl see aution on page inside cover. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. F Filter imensions.9 ().8 (97). (8). (9).87 (99) F. ().9 (). (7) Inches (mm) With utomatic Pulse rain. Ordering Information F * /8 Inch / Inch owl Options Polycarbonate owl Twist rain utomatic Pulse rain Metal owl Twist rain 7 utomatic Pulse rain lements Micron Micron Z dsorber ngineering Level * Will be ntered at Factory Port Type lank NPT SPP SPT OL ITMS R MOST POPULR. Parker Hannifin orporation

7 atalog 7- Technical Specifications F F Series, /8 & / Inch Ports ir Line Filters Technical Information Pressure rop - bar Pressure rop - PSIG Primary Pressure - bar. bar. bar. bar Primary Pressure - PSIG PSIG 9 PSIG PSIG Flow haracteristics F* /8 Inch Ports Flow - SFM Pressure rop - bar Pressure rop - PSIG Primary Pressure - bar. bar. bar. bar Primary Pressure - PSIG PSIG 9 PSIG PSIG Flow haracteristics F* / Inch Ports Flow - SFM Flow - dm /s n Flow - dm /s n! UTION: Polycarbonate bowls and sight dome, being transparent and tough, are ideal for use with Filters and Lubricators. They are suitable for use in normal industrial environments, but should not be located in areas where they could be subjected to direct sunlight, an impact blow, nor temperatures outside of the rated range. s with most plastics, some chemicals can cause damage. Polycarbonate bowls and sight dome should not be exposed to chlorinated hydro-carbons, ketones, esters and certain alcohols. They should not be used in air systems where compressors are lubricated with fire-resistant fluids such as phosphate ester and di-ester types. Metal bowls are recommended where ambient and/or media conditions are not compatible with polycarbonate bowls. Metal bowls resist the action of most such solvents, but should not be used where strong acids or bases are present or in salt laden atmospheres. onsult the factory for specific recommendations where these conditions exist. TO LN POLYRONT OWLS US MIL SOP N WTR ONLY! O NOT use cleansing agents such as acetone, benzene, carbon tetrachloride, gasoline, toluene, etc., which are damaging to this plastic. Metal bowl guards are recommended for all applications. F Filter Kits & ccessories owl Kits Poly owl utomatic Pulse rain...ps8 Twist rain... PS Metal owl utomatic Pulse rain... PS Twist rain... PS7 Filter lement Kits Micron...PS Micron... PS Micron artridge Kit...PS7 dsorber...ps Mounting racket Kit... PS7 Specifications utomatic Pulse rain Tube arb... /8 Inch owl apacity... Ounce Port Threads... /8, / Inch Pressure & Temperature Ratings Polycarbonate owl... to PSIG ( to. bar) F to F ( to ) Metal owl... to PSIG ( to 7. bar) F to 7 F ( to 8 ) utomatic Pulse rain... to PSIG (.7 to 7. bar) at F ( ) or less Weight... lb. (.8 kg) Materials of onstruction ody...zinc owls...transparent Polycarbonate Metal (Zinc) owl w/o Sight Gauge eflector, lement Holder & affle...plastic rains Twist rain ody & Stem...Plastic Seals... Nitrile utomatic Pulse rain Piston & Seals... Nitrile Stem, Seat, daptor & Washers... luminum Filter lements Micron (Standard)...Plastic Micron (Optional)...Plastic dsorber (Optional)...ctivated harcoal Seals... Nitrile Parker Hannifin orporation

8 atalog 7- Miniature F Series Miniature Filters /8 & / Inch Ports F Filters Miniature Features xcellent water removal efficiency Unique deflector plate that creates swirling of the air stream ensuring maximum water and dirt separation asily disassembled for servicing without the use of tools Interchangeable twist and automatic pulse drains High flow: SFM I N ia. istance Required F To Remove ll owls Regardless Of rain Option Port NPT Size Twist rain utomatic Pulse rain Polycarbonate owl /8" F-H F-HS /" F-H F-HS Metal owl without Sight Gauge /8" F-H F-HS /" F-H F-HS Standard part numbers shown bold. For other models refer to ordering information below. For polycarbonate bowl see aution on page inside cover. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop.. (9.7). (9) F.7 (77) F Filter imensions.8 (9.). (.) F.7 (77) Inches (mm) With Metal owl.78 (9). (.) Ordering Information F H /** Port Threads NPT G SPP /8 Inch / Inch owl Polycarbonate Metal lements G Micron H Micron rains and Options lank Manual Twist rain S utomatic Pulse rain U Semi-uto rain X No Internal Parts X* Polyurethane owl X Fluorocarbon Seals X7 With Mounting racket ngineering hange esignator Will be entered at factory. * dd." to overall length. OL ITMS R MOST POPULR. Parker Hannifin orporation

9 atalog 7- Technical Specifications F F Series, /8 & / Inch Ports ir Line Filters Technical Information Primary Pressure - bar.7 bar. bar. bar.9 bar Primary Pressure - PSIG PSIG PSIG 7 PSIG PSIG Pressure rop - bar... Pressure rop - PSIG Flow haracteristics F /8 Inch Ports Inch Ports Flow - SFM Flow - dm /s n F Filter Kits & ccessories owl Kits Metal ()...KY Metal () with utomatic Pulse rain...ksy Polycarbonate ()...KY Polycarbonate () with utomatic Pulse rain... KSY rain Kits utomatic Pulse rain... RKSY Manual Twist rain... SY7- Semi-utomatic Overnight rain...s7 (rains automatically under zero pressure) Filter lement Kits Micron (ll)... KVY Micron (ll)... KY Mounting racket Kit... Must be Ordered with Filter ( ) = owl Type Specifications owl apacity... Ounce Port Threads... /8, / Inch Pressure & Temperature Ratings Polycarbonate owl... to PSIG ( to. bar) F to F (. to ) Metal owl... to PSIG ( to. bar) F to 8 F (. to 8. ) With utomatic Pulse rain... 7 PSIG Max. Press. (.9 bar) Weight Polycarbonate owl.... lb. (. kg) / Unit 7 lb. (.8 kg) / -Unit Master Pack Metal owl.... lb. (. kg) / Unit lb. (. kg) / -Unit Master Pack Materials of onstruction ody...luminum owls...polycarbonate Metal (Zinc) rains...rass Filter lements... Polypropylene Seals...Nitrile 7 Parker Hannifin orporation

10 atalog 7- ompact F Series ompact Filters /, /8 & / Inch Ports F Filters ompact Features Twist rain utomatic rain xcellent water removal efficiency Unique deflector plate and shroud creates a swirling of the air stream ensuring maximum water and dirt separation Large filter element surface guarantees low pressure drop and increased element life Optional automatic float drain available Shown with recommended metal bowl guard High flow: /" SFM /8" 8 SFM /" 8 SFM istance Required F To Remove ll owls Regardless Of rain Option Port Size Twist rain Poly owl / Metal Guard NPT utomatic Float rain /" F-* F-* /8" F-* F-* /" F-* F-* Metal owl / Sight Gauge /" F-* F-8* /8" F-* F-8* /" F-* F-8*.8 (7).7 () F Filter imensions.7 (7). (8). ().7 (9) Inches (mm) With utomatic Float rain.9 () F. (7) Standard part numbers shown bold. For other models refer to ordering information below. For polycarbonate bowl see aution on inside cover. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. Ordering Information F * Port Threads NPT G* SPP * / & /8 inch meet ISO 79- Standard. / Inch /8 Inch / Inch Polycarbonate owl Metal owl Guard / Twist rain Metal owl Guard / uto Float rain owl Options Metal owl Twist rain Sight Gauge / Twist rain 7 uto Float rain 8 Sight Gauge / uto Float rain lement Micron ngineering Level * Will be ntered at Factory. Options lank None OL ITMS R MOST POPULR. 8 Parker Hannifin orporation

11 atalog 7- Technical Specifications F F Series, /, /8 & / Inch Ports ompact Filters Technical Information 7 Primary Pressure - bar. bar. bar. bar Primary Pressure - PSIG PSIG 9 PSIG PSIG 7 Primary Pressure - bar. bar. bar. bar Primary Pressure - PSIG PSIG 9 PSIG PSIG Pressure rop - bar.... Pressure rop - PSIG Flow haracteristics F-* / Inch Ports 7 8 Flow - SFM Pressure rop - bar.... Pressure rop - PSIG Flow haracteristics F-* /8 Inch Ports Flow - SFM Flow - dm /s n 7 Primary Pressure - bar. bar. bar. bar Primary Pressure - PSIG PSIG 9 PSIG PSIG Flow - dm /s n Pressure rop - bar.... Pressure rop - PSIG 7 8 Flow - SFM Flow haracteristics F-* / Inch Ports 9 Flow - dm /s n F Filter Kits & ccessories owl Guard Kit...PS7 owl Kits Poly owl utomatic Float rain...ps7 Twist rain...ps7 Polycarbonate () (Old F)... KY Metal owl utomatic Float rain...ps7 Twist rain...ps7 Sight Gauge / utomatic Float rain...ps7 Sight Gauge / Twist rain...ps7 Metal with Sight Gauge (W) (Old F)...KWY PI Replacement Kit...PS78 rain Kits utomatic Float rain...ps Twist rain...ps Internal uto (ll) (Old F)...SM Manual Twist (ll) (Old F)...SY7- Filter lement Kits Micron...PS7. Micron (,W) (Old F)... KVY. Micron (,W) (Old F)... KY Mounting racket Kit...PS7 Mounting racket Kit (Old F)...(ll) SF-7 Sight Gauge Kit...PS9 Specifications owl apacity... Ounces Sump apacity...7 Ounces Port Threads.../, /8, / Inch Pressure & Temperature Ratings Without ifferential Pressure Indicator: Polycarbonate owl to PSIG ( to. bar) F to F ( to ) Metal owl to PSIG ( to 7. bar) F to 7 F ( to 8 ) With ifferential Pressure Indicator: to PSIG ( to. bar) F to F ( to ) utomatic Float rain to PSIG (. to 7. bar) Weight.... lb. (. kg) Materials of onstruction ody... Zinc owls...transparent Polycarbonate or Metal (Zinc) With or Without Sight Gauge owl Guards... Steel ollar...plastic eflector, Shroud & affle...plastic rains Twist rain ody & Nut...Plastic utomatic Float rain Housing, Float...Plastic Seals... Nitrile Springs, Push Rod...Stainless Steel Filter lements Micron (Standard)...Plastic dsorber (Optional)... ctivated harcoal Seals... Nitrile Sight Gauge... Nylon 9 Parker Hannifin orporation

12 atalog 7- Standard F Series Standard Filters / Inch Ports F Filters Standard Features Twist rain utomatic rain xcellent water removal efficiency Unique deflector plate and shroud creates a swirling of the air stream ensuring maximum water and dirt separation Large filter element surface guarantees low pressure drop and increased element life Optional automatic float drain available Shown with recommended metal bowl guard High flow: /" SFM istance Required F To Remove ll owls Regardless Of rain Option Port Size Twist rain Poly owl / Metal Guard NPT utomatic Float rain /" F-* F-* Metal owl / Sight Gauge /" F-* F-8* Standard part numbers shown bold. For other models refer to ordering information below. For polycarbonate bowl see aution on inside cover. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop.. (8) 7. (78) F Filter imensions. (8) 7.7 (9).7 (8) 7.7 (9) Inches (mm) With utomatic Float rain.97 (77) F.7 (7) Ordering Information F * Port Threads NPT G SPP / Inch owl Options Polycarbonate owl Metal owl Metal owl Guard / Twist rain Metal owl Guard / uto Float rain Twist rain Sight Gauge / Twist rain 7 uto Float rain 8 Sight Gauge / uto Float rain lement Micron ngineering Level * Will be ntered at Factory. Options lank None OL ITMS R MOST POPULR. Parker Hannifin orporation

13 atalog 7- Technical Specifications F F Series, / Inch Ports Standard Filters Technical Information 7 Primary Pressure - bar. bar. bar. bar Primary Pressure - PSIG PSIG 9 PSIG PSIG Pressure rop - bar.... Pressure rop - PSIG 8 Flow - SFM Flow haracteristics F-* / Inch Ports 8 7 Flow - dm /s n 8 9 F Filter Kits & ccessories owl Guard Kit...PS8 owl Kits Poly owl utomatic Float rain... PS8 Twist rain... PS8 Polycarbonate with Plastic owl Guard () (Old F)...K Metal owl utomatic Float rain... PS8 Twist rain... PS8 Sight Gauge / utomatic rain... PS8 Sight Gauge / Twist rain... PS8 luminum () (Old F)...K Metal with Sight Gauge (W) (Old F)... KW PI Replacement Kit... PS78 rain Kits utomatic Float rain... PS Twist rain... PS xternal uto (,W) (Old F)...S xternal uto () (Old F)...S Internal uto (ll) (Old F)... SM Manual Twist (ll) (Old F)... SY7- Filter lement Kits Micron... PS8 Micron (,W) (Old F)...KV Micron (,W) (Old F)...K Mounting racket Kit...PS8 Mounting racket Kit (Old F)... (ll) SF-7 Sight Gauge Kit...PS9 Specifications owl apacity Ounces Sump apacity....8 Ounces Port Threads... /, / Inch Pressure & Temperature Ratings Without ifferential Pressure Indicator: Polycarbonate owl to PSIG ( to. bar) F to F ( to ) Metal owl to PSIG ( to 7. bar) F to 7 F ( to 8 ) With ifferential Pressure Indicator: to PSIG ( to. bar) F to F ( to ) utomatic Float rain to PSIG (. to 7. bar) Weight... lb. (. kg) Materials of onstruction ody...zinc owls... Transparent Polycarbonate Metal (Zinc) With or Without Sight Gauge owl Guards... Steel ollar...plastic or Metal eflector, Shroud & affle...plastic rains Twist rain ody & Nut... Plastic utomatic Float rain Housing, Float... Plastic Seals...Nitrile Springs, Push Rod... Stainless Steel Filter lements Micron (Standard)... Plastic dsorber (Optional)... ctivated harcoal Seals... Nitrile Sight Gauge... Nylon Parker Hannifin orporation

14 atalog 7- Hi-Flow F Series Hi-Flow Filters / & Inch Ports F Filters Hi-Flow Manual rain utomatic rain Features xcellent water removal efficiency For heavy duty applications with minimum pressure drop requirement Unique deflector plate that creates swirling of the air stream ensuring maximum water and dirt separation Large filter element surface guarantees low pressure drop and increased element life micron filter element standard, micron available Metal bowl with sight gauge standard Twist drain as standard, optional auto drain Large bowl capacity Optional high capacity bowl(s) available IN OUT F High flow: /" 7 SFM " SFM Port NPT Size Twist rain utomatic Pulse rain Metal owl / Sight Gauge - oz. /" F-WJ F-WJR " F-8WJ F-8WJR Metal owl without Sight Gauge - oz. /" F-J F-JR " F-8J F-8JR Standard part numbers shown bold. For other models refer to ordering information below. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. F Filter imensions F F-W, F-8W.9 () 7.88 () 8.7 () F-, F-8.9 () inches (mm). (8).9 (). (). ().8 ().8 (). (). () Ordering Information F W J /** Port Threads NPT G SPP / Inch 8 Inch owl oz. Large apacity Metal without Sight Gauge W oz. Metal with Sight Gauge lement G Micron J Micron rains and Options lank Manual Twist rain Q xternal Heavy uty uto rain R Internal uto rain ngineering Level * Will be ntered at Factory. OL ITMS R MOST POPULR. Parker Hannifin orporation

15 atalog 7- Technical Specifications F F Series, / & Inch Ports Hi-Flow Filters Technical Information Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 Flow haracteristics F-WJ /-inch Port Flow - SFM Pressure rop - bar... Pressure rop - PSIG Primary Pressure - bar Primary Pressure - PSIG 7 Flow haracteristics F-8WJ -inch Port Flow - SFM 8 Flow - dm /s n 8 Flow - dm /s n Q Option xternal Heavy uty uto rain S / S For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. rain (/" NPTF) Float (Inside owl) onnection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) F Filter Kits & ccessories owl Kits luminum ()... K Zinc with Sight Gauge (W)...KW rain Kits xternal uto ()... S xternal uto (W)... S Internal uto (ll)... SM Manual (ll)... SY7- Semi-utomatic Overnight rain...s7 (rains automatically under zero pressure) Filter lement Kits Micron (ll)...k Micron (ll)... KV Mounting racket Kit (Pair or Kits Pipe Mounted rackets needed) (/" Unit)... SW7 (" Unit)...SW7 Repair Kits eflector, affle ssembly, and Retaining Rod (,W)... RK xternal uto rain (ll)... RK Internal uto rain (ll)... RKM Metal owl Sight Gauge (W)... RKW Specifications owl apacity luminum owl ()... Ounces Zinc owl (W)... Ounces Port Threads... /, Inch ( ) = owl Type Pressure & Temperature Ratings luminum owl ()... to PSIG ( to. bar) F to F (. to. ) Zinc (W)... to PSIG ( to 7. bar) F to F (. to. ) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. to ) With xternal uto rain (Q)... to PSIG ( to 7. bar) F to F (. to. ) Weight luminum owl ()... 7 lb. (.8 kg) / Unit 8 lb. (.7 kg) / -Unit Master Pack Zinc owl (W).... lb. (.8 kg) / Unit lb. (. kg) / -Unit Master Pack Materials of onstruction ody...zinc owls ()...luminum without Sight Gauge (W)... Zinc with Sight Gauge rain Manual Twist & Overnight...rass Housing R...cetal Housing Q... ronze Filter lements Micron (Standard)...Polypropylene Micron (Optional)...Polypropylene Seals...Nitrile Sight Gauge...Nylon Parker Hannifin orporation

16 atalog 7- Hi-Flow F Series Hi-Flow Filters -/ & -/ Inch Ports F Filters Hi-Flow Manual rain utomatic rain Features xcellent water removal efficiency For heavy duty applications with minimum pressure drop requirement Unique deflector plate that creates swirling of the air stream ensuring maximum water and dirt separation IN OUT F Large filter element surface guarantees low pressure drop and increased element life micron filter element standard, micron available Metal bowl with sight gauge standard Twist drain as standard, optional auto drain Large bowl capacity Optional high capacity bowl(s) available High flow: -/" 9 SFM -/" SFM Port NPT Size Twist rain utomatic Pulse rain Metal owl / Sight Gauge - oz. -/" F-WJ F-WJR -/" F-WJ F-WJR Metal owl without Sight Gauge - oz. -/" F-J F-JR -/" F-J F-JR Standard part numbers shown bold. For other models refer to ordering information below. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. F Filter imensions F F-W, F-W.9 () 8.8 (8) 9. () F-, F-.9 () inches (mm). (9).9 ().9 ().9 ().8 (.).8 (.). (.). (.) Ordering Information F W J /** Port Threads NPT G SPP -/ Inch -/ Inch owl oz. Large apacity Metal without Sight Gauge W oz. Metal with Sight Gauge lement G Micron J Micron rains and Options lank Manual Twist rain Q xternal Heavy uty uto rain R Internal uto rain ngineering Level * Will be ntered at Factory. OL ITMS R MOST POPULR. Parker Hannifin orporation

17 atalog 7- Technical Specifications F F Series, -/ & -/ Inch Ports Hi-Flow Filters Technical Information Primary Pressure - bar Primary Pressure - PSIG 7 Primary Pressure - bar Primary Pressure - PSIG 7. Pressure rop - bar.. Pressure rop - PSIG Flow haracteristics F-WJ -/-inch Port Flow - SFM 8 8 Flow - dm n /s Pressure rop - bar... Pressure rop - PSIG Flow haracteristics F-WJ -/-inch Port Flow - SFM Flow - dm n /s Q Option xternal Heavy uty uto rain S / S For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. F Filter Kits & ccessories owl Kits luminum ()... K Zinc with Sight Gauge (W)... KW rain Kits xternal uto ()...S xternal uto (W)...S Internal uto (ll)... SM Manual (ll)... SY7- Semi-utomatic Overnight rain...s7 (rains automatically under zero pressure) Filter lement Kits Micron (ll)...k Micron (ll)...kv Repair Kits eflector, affle ssembly, and Retaining Rod (ll)... RK xternal uto rain (ll)... RK Internal uto rain (ll)... RKM Metal owl Sight Gauge (W)...RKW Specifications owl apacity luminum ()... Ounces Zinc (W)... Ounces Port Threads...-/, -/ Inch ( ) = owl Type rain (/" NPTF) Float (Inside owl) onnection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) Pressure & Temperature Ratings luminum owl ()... to PSIG ( to. bar) F to F (. to. ) Zinc (W)... to PSIG ( to 7. bar) F to F (. to. ) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. to ) With xternal uto rain (Q)... to PSIG ( to 7. bar) F to F (. to. ) Weight luminum owl () lb. (.9 kg) / Unit lb. (. kg) / -Unit Master Pack Zinc owl (W)... 7 lb. (.8 kg) / Unit 8 lb. (.7 kg) / -Unit Master Pack Materials of onstruction ody...zinc owls ()...luminum without Sight Gauge (W)... Zinc with Sight Gauge rain Manual Twist & Overnight...rass Housing R...cetal Housing Q... ronze Filter lements Micron (Standard)...Polypropylene Micron (Optional)...Polypropylene Seals...Nitrile Sight Gauge...Nylon Parker Hannifin orporation

18 atalog 7- Hi-Flow F Series Hi-Flow Filters & -/ Inch Ports F Filters Hi-Flow Manual rain utomatic rain Features xcellent water removal efficiency For heavy duty applications with minimum pressure drop requirement Unique deflector plate that creates swirling of the air stream ensuring maximum water and dirt separation Large filter element surface guarantees low pressure drop and increased element life micron filter element standard Metal bowl with sight gauge standard Twist drain as standard, optional auto drain Large bowl capacity Optional high capacity bowl(s) available F High flow: & -/" SFM Port NPT Size Twist rain utomatic Pulse rain Metal owl / Sight Gauge - oz. " F-WJ F-WJR -/" F-WJ F-WJR Metal owl without Sight Gauge - oz. " F-J F-JR -/" F-J F-JR Standard part numbers shown bold. For other models refer to ordering information below. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. F Filter imensions F F-W, F-W.9 ().8 (8). () F-, F-.9 () inches (mm). (). (). (). ().9 (8.7).9 (8.7). (.). (.) Ordering Information F W J /** Port Threads NPT G SPP Inch -/ Inch owl oz. Large apacity Metal without Sight Gauge W oz. Metal with Sight Gauge lement J Micron rains and Options lank Manual Twist rain Q xternal Heavy uty uto rain R Internal uto rain ngineering Level * Will be ntered at Factory. OL ITMS R MOST POPULR. Parker Hannifin orporation

19 atalog 7- Technical Specifications F F Series, & -/ Inch Ports Hi-Flow Filters Technical Information Primary Pressure - bar Primary Pressure - PSIG 7 Pressure rop - bar... Pressure rop - PSIG Flow haracteristics F-/ -inch Port 7 Flow - SFM 8 Flow - dm n /s Q Option xternal Heavy uty uto rain S / S For heavy duty applications where the filter is being used to remove large volumes of liquid and/or particulate matter from the airstream, the external automatic drain ( Q option) should be used. rain (/" NPTF) Float (Inside owl) onnection Through owl (/8" NPSM) Manual Push utton rain (Outside owl) F Filter Kits & ccessories owl Kits luminum ()... K Zinc with Sight Gauge (W)... KW rain Kits xternal uto ()...S xternal uto (W)...S Internal uto (ll)... SM Manual (ll)... SY7- Semi-utomatic Overnight rain...s7 (rains automatically under zero pressure) Filter lement Kits Micron (ll)...k Repair Kits eflector, affle ssembly, and Retaining Rod (ll)... RK xternal uto rain (ll)... RK Internal uto rain (ll)... RKM Metal owl Sight Gauge (W)...RKW Specifications owl apacity luminum ()... Ounces Zinc (W)... Ounces Port Threads..., -/ Inch ( ) = owl Type Pressure & Temperature Ratings luminum owl ()... to PSIG ( to. bar) F to F (. to. ) Zinc (W)... to PSIG ( to 7. bar) F to F (. to. ) With Internal uto rain (R)... to 7 PSIG (. to.9 bar) F to F (. to ) With xternal uto rain (Q)... to PSIG ( to 7. bar) F to F (. to. ) Weight luminum owl ().... lb. (.7 kg) / Unit lb. (.99 kg) / -Unit Master Pack Zinc owl (W) lb. (. kg) / Unit 9 lb. (7.9 kg) / -Unit Master Pack Materials of onstruction ody...luminum owls ()...luminum without Sight Gauge (W)... Zinc with Sight Gauge rain Manual Twist & Overnight...rass Housing R...cetal Housing Q... ronze Filter lements Micron (Standard)...Polypropylene Seals...una N Sight Gauge...Nylon 7 Parker Hannifin orporation

20 atalog 7- Hi-Flow F, F Series Hi-Flow Filters -/, & Inch Ports F, F Filters Hi-Flow Features uto rain Heavy-duty cast aluminum housings to withstand operating pressures up to PSIG* ifferential pressure indicator to eliminate the guesswork of element replacement ifferential pressure gauge available, order separately, Kit P-- Unique drain mounting plate design offers a trouble-free method for interchanging and installing external drains F High flow: -/" 8 SFM " SFM " 9 SFM * Without ifferential Pressure Indicator Max. supply pressure is PSIG (.7 bar). G Series Port Size lement Type Part Number (NPT) utomatic rain -/ micron F77P F micron F87P F micron FN7P Standard part numbers shown bold. For other models refer to ordering information below. SFM = Standard cubic feet per minute at 9 PSIG inlet and PSIG pressure drop. 7.8 (98) 8.9 (7) inches (mm) 7.7 (97) 8.88 (.) F Filter imensions.8 (7). (.) 9.7 (8) F Filter imensions.8 (88).9 (9.) 9. (78) F.88 (98.) F. (.8) G. () G. () Ordering Information F 7 7 P F 7 -/ Inch 8 Inch F N Inch owl 7 Metal without Sight Gauge, uto Float rain lement Micron ngineering Level Options N Without ifferential Pressure Indicator P* With ifferential Pressure Indicator G** With ifferential Pressure Gauge Port Threads lank NPT SPP SPT * Max. pressure rating PSIG. ** Gauge ships loose. OL ITMS R MOST POPULR. 8 Parker Hannifin orporation

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

COALESCING FILTERS. IS-F700C Rev. 1 F701, 3/4 and 1 High Efficiency Compressed Air Filters

COALESCING FILTERS. IS-F700C Rev. 1 F701, 3/4 and 1 High Efficiency Compressed Air Filters Pneumatic Division Richland, Michigan USA www.parker.com/pneumatics Bulletin Number COALCING FILTERS Bulletin Description 1F601B Rev. 3 10F / 13F Elements 1C100J Rev. 12 10F Miniature, Installation & Service

More information

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8 to 1-1/2 port sizes Section 12 Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes B7 Miniature eneral Purpose Filter/Regulator 1/8" and 1/" ports...................................le-12-2

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers Filter Contents Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (dsorbing) Filters, and Compressed ir Membrane Dryers Filter Overview..............................LE-Filter

More information

Atlas Copco Quality Air Solutions. Compressed Air Filters

Atlas Copco Quality Air Solutions. Compressed Air Filters Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational

More information

How To Remove A Large Particle From A Large Tank

How To Remove A Large Particle From A Large Tank Delta Series Premium Filters www.numatics.com Table of Contents Delta Series Features and Benefits 3 Science of Coalescing Filtration 4 Water Separator 5 How to Order - Water Separator 6 Pressure and Temperature

More information

HELPFUL HINTS ON PREPARING COMPRESSED AIR

HELPFUL HINTS ON PREPARING COMPRESSED AIR HELPFUL HINTS ON PREPARING COMPRESSED AIR Introduction An efficient compressed air system does not just happen, it is the product of good planning to insure minimum pressure loss in the distribution system

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

Fittings, Tubing & Nipples

Fittings, Tubing & Nipples s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 Parker utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and

More information

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1 200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing

More information

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged

More information

Dryaire Desiccant System

Dryaire Desiccant System Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers Filtering Samples to On-Line Process Analyzers Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers Filtering samples to on-line analyzers Use these guidelines to ensure

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

QIX FRL. IS-B20 Rev. 1 B20 / B21 Filter / Regulator, Installation & Service. IS-D11 Rev. 2 D11-04 & D11-04W Tank Drain, Installation & Service

QIX FRL. IS-B20 Rev. 1 B20 / B21 Filter / Regulator, Installation & Service. IS-D11 Rev. 2 D11-04 & D11-04W Tank Drain, Installation & Service Parker-Watts Pneumatic Division Richland, Michigan USA www.parker.com/watts Document Number QIX FRL IS-F20 Rev. 1 F20 Filter, Installation & Service IS-B20 Rev. 1 B20 / B21 Filter / Regulator, Installation

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

Fittings and Tubing. Low Pressure. Fittings and Tubing - Low Pressure. Low Pressure Fittings and Tubing Features: Pressures to 15,000 psi (1034 bar)

Fittings and Tubing. Low Pressure. Fittings and Tubing - Low Pressure. Low Pressure Fittings and Tubing Features: Pressures to 15,000 psi (1034 bar) ittings and Tubing - Low Pressure ittings and Tubing Low Pressure Pressures to 15,000 psi (1034 bar) Since 1945 utoclave ngineers has designed and built premium quality valves, fittings and tubing. This

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves I-4057-H 2-08 CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE CleanAir for a Quality Finish Selecting the right equipment

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne

More information

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS BULLETIN 240-10-3 June 2004 Supersedes June 1983 Many centrifugal systems get little maintenance. As a result they operate with the refrigerant highly contaminated

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US

Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US Pneumatic Grippers Parallel and Angular Grippers Catalog 19-2/US Catalog 19-2/US OContents GPR Series Rotary vane driven design GPR GPCR Series P5G-HPM(C) Series P5G-HP Series GPT Series P5G-AP Series

More information

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

Stainless Steel Valves For the Sanitary Industries

Stainless Steel Valves For the Sanitary Industries www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves

More information

Accumulators and Receivers

Accumulators and Receivers aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog

More information

World-Class Oil Sampling It is Possible

World-Class Oil Sampling It is Possible www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: info@lubecontrol.com.au

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

introduction to constant level lubrication

introduction to constant level lubrication introduction to constant level lubrication Constant level oilers are designed to maintain a predetermined oil level in a sump, which is necessary for proper lubrication. If the oil level were to drop below

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Oil Sight Glass BENEFITS

Oil Sight Glass BENEFITS 8 L-4090 Schroeder es provide maintenance and lubrication management professionals a complete and immediate visual oil analysis. Constructed of durable cast acrylic, they withstand most petroleum products

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

Needle Valves. Needle Valves - High Pressure. 30SC, 43SC, 30VM, 40VM, 60VM, 100VM & 150V Series. High Pressure. Pressures to 150,000 psi (10342 bar)

Needle Valves. Needle Valves - High Pressure. 30SC, 43SC, 30VM, 40VM, 60VM, 100VM & 150V Series. High Pressure. Pressures to 150,000 psi (10342 bar) Needle Valves High Pressure 30S, 43S, 30V, 40V, 60V, 00V & 50V Series Pressures to 50,000 psi (0342 bar) Since 945, utoclave ngineers has designed and built premium quality valves, fittings and tubing.

More information

Parker Hannifin Corporation will extend its warranty on all pneumatic components to sixty (60) months

Parker Hannifin Corporation will extend its warranty on all pneumatic components to sixty (60) months Pneumatic Products U.S. 5-Year Extended Warranty The Parker 5-Year Extended Warranty will extend its warranty on all pneumatic components to sixty (60) months providing they are correctly installed and

More information

Maintenance Manual. Installation, Service and Adjustments. The more you know, the more you spec' Temprite. www.temprite.com

Maintenance Manual. Installation, Service and Adjustments. The more you know, the more you spec' Temprite. www.temprite.com The more you know, the more you spec' Temprite Maintenance Manual Installation, Service and Adjustments 1555 Hawthorne Lane West Chicago, Illinois 60185 USA 1-800-552-9300 FAX (630) 293-9594 www.temprite.com

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

VG2000 Series Cast Iron Flanged Globe Valves

VG2000 Series Cast Iron Flanged Globe Valves VG2000 Series ast Iron Flanged Globe Valves Installation Instructions Part No. 14-1161-106, Rev. Issued November 15, 2013 Supersedes June 15, 2007 pplications VG2000 Series ast Iron Flanged Globe Valves

More information

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Ingersoll Rand Type-30 Air Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Back then, we called it serving the customer. Today, we call it Solutionizing because your

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

Model 41 Nullmatic Pressure Regulators

Model 41 Nullmatic Pressure Regulators Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION SD41 Rev 13 June 2012 Supersedes Rev 12 Model 41 Nullmatic Pressure Regulators INTRODUCTION The Model 41 Nullmatic Pressure Regulator, shown

More information

Norgren Air Preparation Products and Accessories

Norgren Air Preparation Products and Accessories APC-14 Contents 21 Norgren Air Preparation Products and Accessories Compressed Air Systems............................. ALE--2 Filters............................................ ALE-1-A Oil Removal (Coalescing)

More information

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19 Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR

More information

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Maintenance Manual 31 System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Revised 08-05 NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair

More information

Quick Coupling Products

Quick Coupling Products Quick oupling Products Quick ouplings, Swivels, heck Valves, iagnostic Equipment atalog 3800 US November 2008 Parker Locations Minneapolis, Minnesota Grantsburg, Wisconsin Lincoln, Nebraska hetek, Wisconsin

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed

More information

3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: sales@kellogg-american.com Website: www.kellogg-american.com

3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: sales@kellogg-american.com Website: www.kellogg-american.com Unpackaging & Handling Be sure to carefully inspect the unit before accepting the shipment. If any damage has occurred document it with the trucking company immediately. Contact your Kellogg Distributor

More information

Flushing and Cleaning the A/C System

Flushing and Cleaning the A/C System Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING

More information

Automatic Control Valves WATTS EU 100 Series

Automatic Control Valves WATTS EU 100 Series utomatic ontrol Valves WTTS U Series The Watts Industries range of automatic control valves consist of a hydraulically operated valve, which is controlled by a pilot circuit. The main valve (U ) is the

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors POLARIS AIR COMPRESSOR SERIES engineering excellence stellar performance P - 3 0 0 RELIABLE 100% OIL-FREE ENGINEERED AIR A World Leader for Centrifugal Compressors It s simple: The Polaris Air Compressor

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Redefining Spray Technology

Redefining Spray Technology Redefining Spray Technology Macrospray Single-Point Nozzles Macrospray Spider Nozzles Macrospray nozzle technology Improved performance, lower cost Macrospray nozzle technology from Parker Hannifin s Gas

More information

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2 Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out

More information

TD01211 PIN: NX010 201007.2 nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

TD01211 PIN: NX010 201007.2 nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA Water Motor Alarm MODEL: NX010 GENERAL DESCRIPTION TECHNICAL SPECIFICATIONS Model NX010 Working Water Pressure Range 5 to 175 psig 0.035 to 1.2 MPa (0.35 to 12 bar) Shipping Weight 11 lbs 5 kg Alarm Line

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a

More information

Assembly and Installation Procedures

Assembly and Installation Procedures Assembly and Installation Procedures for Pall Pharmaceutical Grade Capsule Assemblies 1. Introduction The following procedures must be followed for the installation of Pall pharmaceutical grade capsule

More information

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control

More information