WS-40 WS-80 - NOTICE -
|
|
|
- Horatio Patrick
- 9 years ago
- Views:
Transcription
1 SERVICE MANUAL WS-40/80 Hobart Compact Water Softener Installation Instructions WS-40 WS-80 - NOTICE - This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by those not properly qualified. This manual is not intended to be all encompassing. If you have not attended a Hobart Service School for this product, you should read, in its entirety, the repair procedure you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained Hobart Service Technician. The reproduction, transfer, sale or other use of this Manual, without the express written consent of Hobart, is prohibited. This manual has been provided to you by ITW Food Equipment Group LLC ("ITW FEG") without charge and remains the property of ITW FEG, and by accepting this manual you agree that you will return it to ITW FEG promptly upon its request for such return at any time in the future. A product of Hobart Service 701 S. Ridge Ave Troy, OH F25404 Rev. A (0413)
2 WS-40/80 Hobart Compact Water Softener Installation Instructions TABLE OF CONTENTS INSTALLATION... 3 INSTALLATION WS-40/ DISC REPLACEMENT... 8 DISC REPLACEMENT WS-40/ DISC SELECTION DISC SELECTION WS-40/ HOBART SERVICE 2013 F25404 Rev. A (0413) Page 2 of 10
3 WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION INSTALLATION INSTALLATION WS-40/80 SAVE THESE INSTRUCTIONS Disconnect the electrical power to the machine and follow lockout / tagout procedures. 5. Install wheel kit on WS-80. NOTE: Wheel kit for WS-40, already installed. 6. Locate brass in/out adapters, 4 O-rings, and silicone seal lube. 1. Locate water supply line and appropriate drains for softener installation. 2. Install by-pass valving. Fig Locate connector hoses and apply 2 to 3 wraps of Teflon tape to the male threads. Fig Install high temperature prefilter if needed. Fig Thread the brass in/out adapters tightly onto the threaded ends of the connector hoses. Fig Remove all items from shipping package. Page 3 of 10 F25404 Rev. A (0413)
4 WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION Fig Install one O-Ring into each groove of the brass adapter. Fig Install the brass adapters into the in/out ports and secure by reinstalling the bracket and pin. Fig Apply a small amount of seal lube evenly onto each O-ring. Fig Remove the pin and bracket from the softener in/ out port area. Fig The female end of the connector hoses is designed to thread onto 3/4" pipe thread. Perform appropriate plumbing to provide connections from the water supply to the inlet hose/port and from the outlet port/hose. NOTE: The inlet port is identified with an arrow pointing towards the softener controls. The outlet port is identified with an arrow pointing away from the softener controls. These connections may be made before the pressure reducing valve. 14. Insert tubing provided into the drain port on the back of the cabinet and run it to an appropriate drain. Be sure to provide a air gap between the end of the tubing and the top of the drain. NOTE: Drain line length should not exceed 8 feet vertical and 30 feet horizontal from the softener. F25404 Rev. A (0413) Page 4 of 10
5 WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION 15. Insert tubing provided into the overflow port on the back of the softener and run drain lower than the cabinet connection to provide a gravity drain in the event of a internal cabinet leak. Fig Review the meter disc selection chart and the water analysis provided. If no water analysis is provided test the water supply. 17. To test the water supply, use the water analysis test kit available through Pro Products Inc. The recommended kit is #2401 Field Analysis Kit. To order the test kit contact Pro Products at or visit Determine the correct number disc. DISC SELECTION NOTE: Both the WS-40 and the WS-80 have a #4 meter disc installed at the factory. If this is not correct disc for your application, locate meter disc kit and REPLACE DISC. 19. Remove brine valve assembly from cabinet to set float cup. A. Disconnect tubing from brine valve elbow by holding collet and pulling tubing straight away. Fig. 11 B. Remove the brine valve assembly by lifting straight up. C. Set it on a flat surface, to mesure height of float cup. D. Measure from bottom of brine valve to top of float cup. Fig. 12 Page 5 of 10 F25404 Rev. A (0413)
6 WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION Unit Brine Valve Settings Brine Setting WS lb. 6.25" WS lb. 6.5" Float Cup Height 22. Remove four screws securing back cover to salt alarm controller. E. Reinstall brine valve into the cabinet. NOTE: Do not drop brine valve into drum. Dropping may lower float cup, resulting in an improper setting. 20. To install salt alarm system remove paper lining from back of salt alarm connector box. Fig Install three (3) AA batteries into salt alarm controller. NOTE: When installing batteries - be certain to inspect connector to ensure it is secure. Fig Remove plastic lining from Velcro backing located on back of salt alarm controller. Fig Re-install back cover to salt alarm controller. 25. Using the adhesive backing on both devices - place alarm controller and salt alarm connector box in a position that will allow salt alarm controller to be seen and heard when it is activated. 26. Insert phone cable into salt alarm connector box and salt alarm controller. Fig. 14 F25404 Rev. A (0413) Page 6 of 10
7 WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION 33. Continue slowly until internal water flow is heard at softener valve. The softener will automatically run through a regeneration. This process should be repeated in 12 to 15 minutes to flush other resin tank. 34. Check for plumbing leaks. 35. Check unit for proper operation. Fig Check for proper operation by pressing the recessed red button on bottom of salt alarm controller. If controller is operating properly - the indicator light will flash and an audible tone will be heard. 28. Fig Add a clean grade of salt at this time. Higher grades of Pelletized Salt for impurities and solubility should be used. NOTE: Do not use rock salt or solar salt. 30. Open inlet valve slowly allowing system to pressurize. 31. Water and air will be expelled from drain until system is completely pressurized. 32. A manual regeneration should be started to purge air and color from softening system. This is done by pushing down on actuator with a Phillips screwdriver and rotating clockwise slowly until pressure is felt. Page 7 of 10 F25404 Rev. A (0413)
8 WS-40/80 Hobart Compact Water Softener Installation Instructions - DISC REPLACEMENT DISC REPLACEMENT WS-40/80 1. Remove screws and cap cover from level one. DISC REPLACEMENT Fig Remove meter drive pawl. Fig Remove balance piston. Fig Remove balance piston o-ring and balance piston spring. 5. Remove meter disc. Fig. 22 Fig. 23 F25404 Rev. A (0413) Page 8 of 10
9 WS-40/80 Hobart Compact Water Softener Installation Instructions - DISC REPLACEMENT 6. Install correct meter disc and reassemble in reverse order. NOTE: Be certain to start cap screws by hand rotating backwards until screw drops into thread then tighten. An alternating, crossing pattern should be used while tightening cap screws to ensure correct cap fit. Page 9 of 10 F25404 Rev. A (0413)
10 WS-40/80 Hobart Compact Water Softener Installation Instructions - DISC SELECTION DISC SELECTION DISC SELECTION WS-40/80 The amount of hardness removed (in compensated gpg) will be based on the amount of brine and the meter disc selected. 1. Determine the compensated hardness. This requires a hardness test and an iron test on raw water at the application site. Compensated hardness is calculated by multiplying the ferrous iron (in ppm) by 3 and adding it to the grains of hardness. 2. To test the water supply, use the water analysis test kit available through Pro Products Inc. The recommended kit is #2401 Field Analysis Kit. To order the test kit contact Pro Products at or visit 3. Determine the salt setting. The salt setting is determined by taking the compensated hardness (calculated in step 1 above) and using the specification table for model WS-40 or WS Verify the float cup setting. Use specifications for the WS-40 or WS-80 to determine the correct setting the float cup height. Specifications WS-40 WS-80 Salt usage / generation 1.0 lbs. 1.4 lbs. Capacity 2,527 grains 4,818 grains Efficiency 2,527 gr./lb. 3,442 gr./lb. Dosing 5.5 lbs./cu. ft. 3.5 lbs./cu. ft. Float cup setting 6.25" 6.5" WS-40 Disc Selection * Disc Number Compensated Hardness * Gallons Between Regeneration Rregeneration Gallons 15 psig * Compensated hardness in gpg = Hardness + (3 x Fe in mg/l) WS-80 Disc Selection * Disc Number Compensated Hardness * Gallons Between Regeneration Rregeneration Gallons 15 psig * Compensated hardness in gpg = Hardness + (3 x Fe in mg/l) F25404 Rev. A (0413) Page 10 of 10
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
Owner s Manual. 5600 / 5600 Econominder
5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job
WATER SOFTENER SYSTEMS
INSTALLATION MANUAL WATER SOFTENER SYSTEMS HousePure Models HP-Soft-2 HP-Soft-4 736-0137 Water, Inc. 1044 East Del Amo Blvd., Carson, CA 90746 www.waterinc.com 310-885-4400 P/N 41482 Rev A 06/04 Table
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
Model 5600 & 5600 Econominder
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
Model 5600 & 5600 Econominder
Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet.........................................................................
MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-15T-30T using the 255/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description 1 Model
MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version
MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging
Clean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Metermatic SE Automatic Water Softener. Operation Manual
Metermatic SE Automatic Water Softener Operation Manual Page 7 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly
Fleck 7000 Softener Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.
MODEL 9000 Service Manual IMPORTANT: Fill in pertinent information on page for future reference. Job Specification Sheet * JOB NO. * MODEL NO. * WATER TEST * CAPACITY PER UNIT MAX. PER REGENERATION * MINERAL
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Softener Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 MAIN COMPONENTS Your water treatment
Model 5600SE Downflow
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1
R Water Conditioning Owner s Manual R4039 RXD Water Softener This manual contains information on setting the controller and normal operating maintenance required by the owner. Page 1 UNPACKING INFORMATION
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Installation Instructions
Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED TOILET FLUSH VALVE.,.8,.,./. &.8/. GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for -/" Top Spud Bowls
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)
46 Brakes - Mechanical Components (Page GR-46) Front brakes Brake pads, removing and installing Brake pads, removing and installing FN 3 brake caliper, servicing FS III brake caliper, servicing Rear wheel
USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling
JC Carter LLC LNG Couplings USER MANUAL 10 GPM Small Single Line Cryogenic Coupling Models 50E722 Nozzle and 50E721 Receptacle User s Manual and Installation Guide! Warning: Read the User s Manual and
Pro-OX 7800 Iron Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Pro-OX 7800 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual
Series 255 Valve / 460i Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Introduction............................... 2 Series 255/460i Demand Control System
10/20 COMBINATION UNIT
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual 10/20 COMBINATION UNIT with the 255/742 Logix Control Valve With Vortech October 2006 Table of Contents Page No. Topic
Installation Instructions 4662.003
Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work
Revised 02-00 TECHNICAL BULLETIN Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves This technical bulletin covers both cab and chassis leveling valves manufactured by Meritor WABCO. While the
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions
MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions MONITOR PRODUCTS, INC. 15400 Flight Path Dr Brooksville, FL 34604 Tel: 1-800-334-4591 or 352-544-2620 Sales: ext 201 Technical Support:
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT
Tech Bulletin Hose / Cord Replacement and Required Wraps Series RT Replacing the Hose To remove the hose - Pull out the hose leaving 2 to 3 feet on the spool. Engage the latch pawl. Remove the U-bolt nuts
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
PLUMBING CARE AND REPAIR
PLUMBING CARE AND REPAIR No special skills are required for any of the repairs described in this section. Plumbing repairs are seldom dangerous unless leaking water is soaking areas where there are electrical
Thank you... Welcome to your new world of better living with water2buy s Aquasmart Water softeners. How your Aquasmart TM water softener works
Thank you... Welcome to your new world of better living with water2buy s Aquasmart Water softeners. If this is your first experience of Aquasmart softened water in your home, you ll be amazed at the marvelous
EcoSoft Water Softener. General Installation Guide
EcoSoft Water Softener General Installation Guide Planning Our Softener Installation Please observe any local or national regulations concerning the installation of your water softener. Check that there
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
Autotrol 460i and 460TC Control System
Autotrol 460i and 460TC Control System Installation and Operation Instructions www.pentairaqua.com Contents 460i Electronic Demand System...2 Special Features 460i...2 California Proposition 65 Warning...2
CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP
CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP Feb 5, 2003 1 CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING COMPLETE SYSTEM CHECK - PNEUMATIC PUMP THE SYSTEM DOES
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Water Tec of Tucson. WS1TA Twin Alterna ng Water so ener
Water Tec of Tucson WS1TA Twin Alterna ng Water so ener Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 MAIN COMPONENTS Your water treatment
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
CHROME FRONT BRAKE MASTER CYLINDER KIT
-J075 REV. 009-0-0 CHROME FRONT BRAKE MASTER CYLINDER KIT GENERAL Kit Number 5-99D, 5-99D Models These Chrome Master Cylinder Kits are designed to replace the original equipment front brake master cylinder
GENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
INSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL Model 550, 700 and 900 Water Softeners Version 4 WaterBoss 4343 S. Hamilton Road, Groveport, Ohio 43125 Table of Contents QUESTIONS?... 1 GETTING MAXIMUM EFFICIENCY FROM
OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590
OWNER S MANUAL MODEL NOS. 625.348570 625.348590 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Cleaning & Sanitisation
Cleaning & Sanitisation Notice: The information and/or procedures presented in the following demonstration(s) should be performed by a trained Water Cooler Service Technician only. Never attempt to service
OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual
OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The
2006 HEADSHOK Service Video #1
LEFTY SPEED DLR DAMPING CARTRIDGE This document explains how to properly remove, disassemble, inspect, reassemble and reinstall the Lefty Speed DLR2 damping cartridge. It is a document to be used in conjunction
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
FILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
Before repairing your toilet, you must determine
Before repairing your toilet, you must determine which type of toilet you have. Pressurized Toilets If you have a pressurized toilet, it is recommended that you call a licensed plumbing contractor to repair
Iron Air Charge 2510-SXT Installation & Start-Up Guide
Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water
REPAIR AND MAINTENANCE MANUAL
REPAIR AND MAINTENANCE MANUAL Professional Pest Control Application Equipment Prime Line Sprayers B&G Equipment Company 135 Region South Drive, Jackson, GA 30233 800.544.8811 Phone 678.688.5601 Fax 678.688.5633
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts
Fiberstars Lighted Laminar Flow Fountain Installation Manual
Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation
7500 Pro-Ox Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 7500 Pro-Ox Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
PARTS NEEDED FOR CONVERTING FROM LP TO NG
1 6 7 8 3 5 4 10 9 2 PARTS NEEDED FOR CONVERTING FROM LP TO NG Number Description 1 30" NG Manifold 2 NG side burner valve 3 NG Regulator 4 Rear I/R NG orifice 4 Rear I/R NG orifice 5 Side burner NG orifice
KEYPAD LOCK RETROFIT KIT
KEYPAD LOCK RETROFIT KIT INSTRUCTIONS FOR ASSEMBLY IMPORTANT READ & SAVE THESE INSTRUCTIONS Tools Required for Assembly 5/32 hex (Allen) wrench #2 Phillips screwdriver Isopropyl alcohol or alcohol wipes
Water Specialist 1 Control Valve Series Model: WS1
Water Specialist 1 Control Valve Series Model: WS1 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training of the OEM and for the OEM to use
Installation Instructions / Warranty
Installation Instructions / Warranty Vertical Spray Bidet Fitting Rough 1322X181 Citterio 39224xx0 Citterio 39225xx0 Starck 10220xx0 Steel 35220800 Uno 38220xx0 Terrano 37224xx0 Terrano 37225xx0 Carlton
OPERATING INSTRUCTIONS AND PARTS LIST FOR U075075 U100058 UNDERGROUND HOSE REELS
OPERATING INSTRUCTIONS AND PARTS LIST FOR U075075 U0005 FORM NO.: 3-00 REV: RAIN BIRD CORPORATION ONE REELCRAFT CENTER COLUMBIA CITY, IN 675 (00) -33 / (60) - FAX: (60) -605 U0005 MODEL NUMBER SIGNIFICANCE
FLUSHOMETER - TANK SYSTEM
Owner s Service Manual 501-A Series FLUSHOMETER - TANK SYSTEM 501-A Series FLUSHMATE 501-A SERIES (D) (E) (C) 2 3 (B) 1 4 (F) (A) 6 5 List of Components for 501-A Series*: 1. Lower Supply Group w/hose
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)
Form TI420-KIT A Watts Industries Co. TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9) DESCRIPTION Thank you for purchasing a Powers kit. The Powers kit you
Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:
Guide for Modified Assembly: Lightning McQueen By: Collin Patterson, University of Delaware Materials and Tools: PVC o 40 inches of 1 in diameter PVC o 25 inches of ¾ in PVC o 4 x 1 in elbows o 2 x ¾ in
SureSite Magnetic Liquid Level Indicator
SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)
Troubleshooting Guide for Jacks Down LED Lights
Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any
INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5
CI100018 INSTALLATION INSTRUCTIONS FOR 2006-2009 VW MK5 Rabbit, Jetta 2.5L These instructions are applicable to vehicles equipped with either manual or automatic transmissions Thank you for choosing to
Rebuild Instructions for 70001 and 70010 Transmission
Rebuild Instructions for 70001 and 70010 Transmission Brinn, Incorporated 1615 Tech Drive Bay City, MI 48706 Telephone 989.686.8920 Fax 989.686.6520 www.brinninc.com Notice Read all instructions before
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Calcite PH Nutralizer System
Calcite PH Nutralizer System Installation, Operation & Maintenance Manual Facts About Calcite Ph Neutralizers Calcite is a crushed and screened white marble media which can inexpensively be used to neutralize
2020c WATER SOFTENER. Owner s Manual. visit www.kinetico.co.uk
2020c WATER SOFTENER Thank you for choosing Kinetico to improve the quality of your water. You will immediately begin to notice the numerous benefits of having quality water throughout your home and the
with installation dynafact boost GAUGE this manual is for use with systems 64050-64054
owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
Thermostatic Valve Replacement Cartridge and Rebuild Kit
Thermostatic Valve Replacement Cartridge and Rebuild Kit Installation Instructions Rebuild kit for Ondine Thermostatic Mixing Valves including Models 25071 (1/2-inch) and 25072 (3/4-inch). Also fits models
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
Installation and Maintenance Instructions
Installation and Maintenance Instructions Limited One Year Warranty T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship