Introduction. System Schematic ADDRESSABLE SPUR CIRCUIT LOOP 1 ADRRESSABLE LOOP CONVENTIONAL SOUNDERS CONVENTIONAL SOUNDERS LOOPS 2-4

Size: px
Start display at page:

Download "Introduction. System Schematic ADDRESSABLE SPUR CIRCUIT LOOP 1 ADRRESSABLE LOOP CONVENTIONAL SOUNDERS CONVENTIONAL SOUNDERS LOOPS 2-4"

Transcription

1 Introduction System Schematic ADDRESSABLE SPUR CIRCUIT LOOP 1 ADRRESSABLE LOOP ~ CONVENTIONAL SOUNDERS LOOPS 2-4 ~ CONVENTIONAL SOUNDERS MODBUS OUTPUT TO BMS SYSTEM BACNET OUTPUT TO BMS SYSTEM SITE MONITOR SYSTEM SITE GRAPHICS SYSTEM CF3000 ~ CW9000 ~ CTPR3000 ~ EC700 LON-FO CFSFL01 EC200 EXT 24V EC650 EXT 24V ECO232 ECO232 NC NC NC FIBRE OPTIC ~ NC LOCAL AREA NETWORK NC ~ UP TO MAX 126 NETWORK NODES EXT 24V EC400 EC400 EC540 CF1100/1200 CF3000

2 Introduction Network Schematic Max 126 nodes Control Panels, Network Repeaters, Network Modules Topology Fire rated RS485 screened twisted pair, ie, Draka m cable max of copper network between boosters Data Available Panel Number, Loop Number, Device No. / Desc / type, Zone No. / desc MODBUS OUTPUT TO BMS SYSTEM BACNET OUTPUT TO BMS SYSTEM SITE MONITOR SYSTEM SITE GRAPHICS SYSTEM CF3000 ~ CW9000 ~ CTPR3000 ~ EC700 LON-FO CFSFL01 EC200 EXT 24V EC650 EXT 24V ECO232 ECO232 NC NC NC FIBRE OPTIC ~ NC LOCAL AREA NETWORK NC ~ UP TO MAX 126 NETWORK NODES EXT 24V EC400 EC400 EC540 CF1100/1200 CF3000

3 Introduction Advanced Network Modules Range NCDR Dual Redundancy Network Card (V2) CFSFL01/02 LON (network) to Fibre Optic interface, max 15K FO length EC400 LON (network) to TCP/IP interface EC540 LON (network) booster, splits network and resends data to increase range ECO232 LON (network) to RS232: Site Graphics & Site Monitor EC200 LON (network) to BMS Gateway EC650 LON (network) to BACnet interface EC700 BMS Gateway to ModBus interface

4 Standard Hardware Standard Network Card Connections Cable Enhanced fire rated data cable, Max 1000m length Draka core twisted pair with screen Screening Connect screen to ground at one end only Termination Resistor termination 102 (2 x 51 ) per card Radial Network Remove resistors at all network cards except the two ends 102 at each end = 51 across network Ring Network Remove resistors at all network cards except one Link out 1 resistor leaving 51 across network EC540 Booster: treat the network either side as separate networks NETWORK CONNECTIONS A-X, B-Y OUT IN Y X B A TERMINATION RESISTORS RIBBON CABLE TO CONTROL PANEL

5 Standard Hardware Standard Network Termination Radial Network Remove resistors at all network cards except the two ends 102 at each end = 51 across network PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 PANEL 4 OF NONE NONE 102

6 Standard Hardware Standard Network Termination Radial Network with Booster Remove resistors at all network cards except the two ends 102 at each end = 51 across network PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 EC540 BOOSTER 24V SUPPLY 102 NONE TO NEXT PANEL ETC

7 Standard Hardware Standard Network Termination Ring Network Remove resistors at all network cards except one Link out 1 resistor leaving 51 across network PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 PANEL 4 OF 4 51 NONE NONE NONE

8 Standard Hardware Standard Network Termination Resistor Termination on network card 102 (2 x 51 resistor) To give 51 reading across network pair at any point Radial Network Remove resistors at all network cards except the two ends 102 at each end = 51 across network Ring Network Remove resistors at all network cards except one Link out 1 resistor leaving 51 across network A B All () None (no resistor) One (51 ) Terminal Mounted A B A B O/C A B 51 S/C 102 LEAVE ALL RESISTORS INTACT CUT HERE TO REMOVE FROM CIRCUIT SOLDER LINK ACROSS ONE RESISTOR SOME DEVICES MAY NOT HAVE INBUILT RESISTORS

9 NCDR: Network Card Dual Redundancy Dual Network Channels Cable Enhanced fire rated data cable, Max 1000m length Draka core twisted pair with screen Screening Connect screen to ground at one end only Termination As per standard network card, but for each channel NETWORK 2 CONNECTIONS IN-OUT SCREEN CONNECTIONS OUT IN NETWORK 1 CONNECTIONS IN-OUT OUT IN Y X B A TERMINATION RESISTORS RIBBON CABLE TO CONTROL PANEL

10 NCDR: Network Card Dual Redundancy Dual Network Channels Network 1 and Network 2 Automatic Switching in event of fault Network Protocol V2 option must be selected PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 PANEL 4 OF NONE NONE NONE NETWORK CHANNEL 1 NETWORK CHANNEL 2

11 CFSFL01/02: Lon (Network) to Fibre Optic Interface Single or Dual Channel Requires 2 for a dual network Fibre Single Mode x 2 (Tx & Rx) 9/125 micron 15Km max SC Type connectors FIBRE CONNECTIONS 0V SCREEN NETWORK A NETWORK B

12 CFSFL01: Lon (Network) to Fibre Optic Interface Single Channel network Radial, ring or part network PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 PANEL 4 OF 4 NONE NONE 2 x SINGLE MODE FIBRE

13 CFSFL01: Lon (Network) to Fibre Optic Interface Single Channel network Radial, ring or part network PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 PANEL 4 OF 4 NONE x SINGLE MODE FIBRE

14 CFSFL02: Lon (Network) to Fibre Optic Interface Dual Channel network Radial, ring or part network PANEL 1 OF 4 PANEL 2 OF 4 PANEL 3 OF 4 PANEL 4 OF 4 2 x SINGLE MODE FIBRE

15 CFSFL01/2: Lon (Network) to Fibre Optic Interface Many possible combinations PANEL 3 OF 7 PANEL 5 OF 7 PANEL 1 OF 7 PANEL 2 OF 7 PANEL 4 OF 7 PANEL 6 OF 6 PANEL 7 OF 7 CFSFL01 or CFSFL02 CFSFL02 CFSFL02 CFSFL02 CFSFL01 or CFSFL02 2 x SINGLE MODE FIBRE

16 EC400: Lon (Network) to TCP/IP Interface Network via PC network / internet / etc Requires 2 for a dual network Use Hyper Terminal for configuration IP address Inbuilt Web Server for IP configuration IP address Passwords PROGRAMMING NETWORK CONNECTION ETHERNET CONNECTION 24V DC

17 EC400: Lon (Network) to TCP/IP Interface Requires fixed IP address Useful for facilities management PANEL 3 OF 3 PANEL 1 OF 3 PANEL 2 OF 3 NETWORK NETWORK

18 EC540: Lon (Network) Booster Extend radial network length Effectively splits a network into multiple networks Requires 2 for a dual network Max 5 per network Any more may cause transmission delays NETWORK CONNECTION

19 EC540: Lon (Network) Booster Radial Network Terminate network either side of booster PANEL 1 OF 3 PANEL 2 OF 3 PANEL 3 OF 3 NONE 1000M MAX 1000M MAX

20 EC0232: Lon (Network) to RS232 Interface PC connection No network address required Versions EC0232: Site Monitor, Site Graphics, EC0232PAVA: EVAX HMX PAVA EC0232PAVA3D: EVAX HMX PAVA 3 minute time delay

21 EC0232: Lon (Network) to RS232 Interface Typical Example PANEL 1 OF 2 PANEL 2 OF 2 SITE GRAHICS OR SITE MONITOR EC M MAX

22 EC200: Lon (Network) to BMS Gateway Translation for BMS connection Requires EC700

23 EC700: BMS Gateway to MODbus interface Translation for BMS connection Requires EC700 Verify requirement spec as protocol implementation may vary

24 MODbus Interface Typical Example PANEL 1 OF 2 PANEL 2 OF 2 EC200 EC700 MODBUS SYSTEM 1000M MAX

25 EC650 to BACnet interface Translation for BMS connection Direct network connection Verify requirement spec as protocol implementation may vary

26 BACnet Interface Typical Example PANEL 1 OF 2 PANEL 2 OF 2 EC650 BACNET SYSTEM 1000M MAX

27 Network Standard Network Setup At each control panel Number of panels on network Panel Address E.g., Panel 1 of 4 Network Response (to commands received) Silence Reset Evacuate Fire Fault Pre Alarm Network Filter Select which Panels to respond to

28 Operation Fault Finding a Network Lon Network Error Check panel address and totals settings Check network termination Check network cable insulation and continuity readings Misc Hard reset panel, then clear watchdog fault with soft reset Generate fire or fault and check transmission and reset

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

Technical Description U00980 Revision 2

Technical Description U00980 Revision 2 Technical Description U00980 Revision 2 TLON Author: Mikael Rivarola Date of issue: 2000-01-07 Date of rev: 2009-01-30 Table of contents 1 Introduction 2 2 Definitions / Explanations 3 3 General description

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

HARTING econ 3000 Introduction and features

HARTING econ 3000 Introduction and features HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

DK40 Datasheet & Hardware manual Version 2

DK40 Datasheet & Hardware manual Version 2 DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...

More information

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor WaveReady CFM Optical Link Monitoring System: Continuous Fiber Monitor www.lumentum.com Data Sheet The Lumentum Continuous Fiber Monitor (CFM) offers a compact, modular solution for performance monitoring

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier

More information

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce

More information

TX2123 RS485 TO ETHERNET ADAPTOR

TX2123 RS485 TO ETHERNET ADAPTOR TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

PROFINET Diagnostics Software and Tools

PROFINET Diagnostics Software and Tools PROFINET Diagnostics Software and Tools Dr. Xiu Ji Static wiring test, diagnostics Live system diagnostics Basics of PROFINET Content PROFINET Diagnostics by Dr. Xiu Ji, Page 2 What is PROFINET? PROFINET

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

MSL1000 Monitored Serial Link Interface Manual V1.01

MSL1000 Monitored Serial Link Interface Manual V1.01 Audix Systems, Station Road, Wenden, Saffron Walden, Essex, CB11 4LG. Telephone: +44(0)1799 540888 Facsimile: +44(0)1799 541618 www.tycosafetyproducts-europe.com www.audixsystems.co.uk MSL1000 Monitored

More information

OPTICAL FIBER repeaters/ isolators

OPTICAL FIBER repeaters/ isolators OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,

More information

Using installed Fieldbus Wiring to carry Ethernet Communications

Using installed Fieldbus Wiring to carry Ethernet Communications Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0 T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop

More information

TECHNICAL BULLETIN. Wiring Diagrams. TPI Wiring. TB1010-04 Rev. March 4, 2013 Page 1 of 5. Switch Settings 3 PHASE POWER SUPPLY 3 PHASE POWER SUPPLY

TECHNICAL BULLETIN. Wiring Diagrams. TPI Wiring. TB1010-04 Rev. March 4, 2013 Page 1 of 5. Switch Settings 3 PHASE POWER SUPPLY 3 PHASE POWER SUPPLY Page 1 of 5 Wiring and Programming of the TPI (Turbine Pump Interface) with an FEPetro SCIII (3-Phase Smart Controller) Overview The STP-SCIII 3-Phase Smart Controller can be controlled by the INCON TPI

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen) Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Storage Area Network

Storage Area Network Storage Area Network 2007 Infortrend Technology, Inc. All rights Reserved. Table of Contents Introduction...3 SAN Fabric...4 Advantages of SAN Solution...4 Fibre Channel SAN vs. IP SAN...4 Fibre Channel

More information

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A USER S MANUAL Ethernet 10/100 Transceiver Series DL221/DL221A June 1999 ETHERNET 10/100 TRANSCEIVER INSTRUCTION MANUAL SERIES DL221/DL221A INTRODUCTION Thank you for purchasing the Radiant Communications

More information

Square D Model 6 Motor Control Centers

Square D Model 6 Motor Control Centers Square D Model 6 Motor Control Centers with Ethernet Communications What is industrial Ethernet? Over the past few years the use of Ethernet communications has spread into every corner of the business

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O

More information

JUNIOR V3. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL GLOBAL REVISION 2.3 FIRE EQUIPMENT QUEUE REVIEW STATUS ZONES

JUNIOR V3. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL GLOBAL REVISION 2.3 FIRE EQUIPMENT QUEUE REVIEW STATUS ZONES STATUS ZONES QUEUE REVIEW FIRE FAULT 1 2 3 4 5 6 7 8 FIRE PRE-ALARM FAULT TEST DISABLED TEST SYSTEM ON MANUFACTURED IN THE E.U. TO THE REQUIREMENTS OF EN54 Pt 2&Pt 4 1999 DISABLED FAULTS KEYPAD CONTROLS

More information

Using High Availability Technologies Lesson 12

Using High Availability Technologies Lesson 12 Using High Availability Technologies Lesson 12 Skills Matrix Technology Skill Objective Domain Objective # Using Virtualization Configure Windows Server Hyper-V and virtual machines 1.3 What Is High Availability?

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL

ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made

More information

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Page 1 of 13 Table of Contents 1 OVERVIEW... 3 2 INSTALLING AND CONFIGURING THE ANYBUS -X GENERIC GATEWAY AND ETHERNET

More information

c o m m u n i c a t i o n n e t w o r k s

c o m m u n i c a t i o n n e t w o r k s c o m m u n i c a t i o n n e t w o r k s Founded in 2007, by George Lichtblau Former founder and owner of IFS. Majority of ComNet employees came from IFS. Massive industry experience. Same faces. New

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 3DLevelScanner II Different Ways of Connecting to 3DLevelScanner II A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 2 Different Ways of Connecting to 3DLevelScanner II Version 3.0 Table

More information

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) MICROSENS General The MICROSENS Installation Switch enables the connection of 5 end devices via twisted pair cable which also

More information

BACnet Automation Interface Module (Network Version)

BACnet Automation Interface Module (Network Version) Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP

More information

Table of Contents. Creating a VC1000 Network... 3

Table of Contents. Creating a VC1000 Network... 3 2 Table of Contents Creating a VC1000 Network... 3 Topology... 3 Unit ddressing... 4 Terminating Resistors... 5 Shielding... 5 Interconnecting the common... 6 ias Resistors... 6 VC1000 Hardware Configuration...

More information

Setup guide. point to point wall plate extenders

Setup guide. point to point wall plate extenders SDS-1002/3 point to point wall plate extenders Setup guide For more information visit our website, or talk to one of our technical team tel: +44 (0) 1306 628264 www.smart-e.co.uk SDS-1002 & 1003 SETUP

More information

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches ComNet Fiber Optic and Ethernet Transmission Equipment is setting the standard for value and performance. ComNet is a major provider of video, audio and data transmission, and network communication solutions

More information

Networks. The two main network types are: Peer networks

Networks. The two main network types are: Peer networks Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among

More information

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience

More information

FBs-CM25/CM55/CBE. Ethernet Module. User s Manual

FBs-CM25/CM55/CBE. Ethernet Module. User s Manual FBs-CM25/CM55/CBE Ethernet Module User s Manual Ver. 2.1 Fatek Automation Corp. 7/1/2004 1. Preface...2 2. Specification...2 2.1 Serial Communication Connector(FBS-CM25E/CM55E only)...2 2.2 Ethernet Serial

More information

3500/22M Transient Data Interface

3500/22M Transient Data Interface 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

Introduction Media converters

Introduction Media converters Optical media converter Introduction s The use of fiber optics is advisable when reliability demands are high or there are long distances to cover. One simple and inexpensive solution is the Weidmuller

More information

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation SAUTER novapro Open: B-AWS BACnet Advanced Workstation SAUTER novapro Open: A SCADA system that provides all needs for any type of building. Open for public buildings Secure for FDA and GAMP Flexible for

More information

Vibration Monitoring System Adash 3600

Vibration Monitoring System Adash 3600 " User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,

More information

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0 GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...

More information

Building Management System Gateway. Installation and Commissioning Manual Man-1181 Issue 07 June 2013

Building Management System Gateway. Installation and Commissioning Manual Man-1181 Issue 07 June 2013 Building Management System Gateway Installation and Commissioning Manual Man-1181 Issue 07 June 2013 Index Page 1. Overview... 3 2. Power Requirements... 4 2.1 OpenConnect Gateway Power Requirements...

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4

More information

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Ethernet. Customer Provided Equipment Configuring the Ethernet port. Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.

More information

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for: Broadband Groomer F-330 Series Falco is the industry first Access Unit designed to offer access to SDH/SONET/PDH backbones by different. extends the usefulness of WAN/LAN to and GbE backbones. Falco combines

More information

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle

More information

SALES SUPPORT DOCUMENT

SALES SUPPORT DOCUMENT SALES SUPPORT DOCUMENT ML-1630 MAXLOGIC SUPERVISOR SOFTWARE FOR MONITORING AND MANAGING ADDRESSABLE SYSTEM ML-1630 Supervisor software provides monitoring and controlling fire and fault events. Program

More information

Auxiliary equipment for communication with the EuroProt protective devices

Auxiliary equipment for communication with the EuroProt protective devices Auxiliary equipment for communication with the EuroProt protective devices RS232 cable This cable is used to connect the RS232 connector located on the front panel of the EuroProt devices to the 9 pin

More information

INTRODUCTION TO MEDIA CONVERSION

INTRODUCTION TO MEDIA CONVERSION WHITE PAPER INTRODUCTION TO MEDIA CONVERSION Table of Contents Introduction 1 What is a Media Converter? 1 Advantages of Media Conversion Technology 1 Benefits of Fiber Optic Cabling 2 Types of Media Converters

More information

HC Products ILF-100WD User Manual

HC Products ILF-100WD User Manual Internet Line Fault Monitor 2012 HC Security Products Patent Pending 7711 Idlewild RD. Indian Trail, NC 28079 www.hcproductlines.com Tel: 877-908-CCTV (2288) Fax: 888-801-8295 Rev. 2.00 03/22/2012 Table

More information

EtherDevice Switch EDS-726 Series

EtherDevice Switch EDS-726 Series Managed Redundant EtherDevice TM Switch Solutions EtherDevice Switch EDS-726 Series 26-Port Gigabit Ethernet Switch Modular, Managed, Redundant Features Industrial Networking Capability Redundant Gigabit

More information

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide 8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

REGTRONIC OPERATING INSTRUCTIONS

REGTRONIC OPERATING INSTRUCTIONS REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:

More information

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...

More information

sat-nms SMU Signal Management Unit

sat-nms SMU Signal Management Unit sat-nms SMU Signal Management Unit Application Note 2014, SatService GmbH www.satnms.com SMU-APP-1408-1 1/37 1 System Description and Configuration of sat-nms SMU The sat-nms SMU is the unit you were always

More information

DCM. Product Brochure. Diagnostic Communication Master

DCM. Product Brochure. Diagnostic Communication Master DCM Product Brochure Diagnostic Communication Master DCM The DCM Diagnostic Communication Master is the best solution for the control of actuators from a remote control room through a two-wire transmission-mode

More information

6.4-7.1 GHz SDH Digital Radio

6.4-7.1 GHz SDH Digital Radio 6.4-7.1 GHz SDH Digital Radio Super SkyLink Digital Microwave Radio IDU Interface SDH STM-1/Optical or 63E1 Software Defined IDU Multi-function defined by software : Frequency Range Modulation Capacity

More information

NESS-APX. Training Manual

NESS-APX. Training Manual NESS-APX IP Reporting Module Training Manual NESS-APX IP Monitoring Module Training Manual Rev1 N55 Product Part No. 106-201 Document Part No. 890-433 Innovative Electronic Solutions www.ness.com.au NSW

More information

EUCIP - IT Administrator. Module 3 LAN and Network Services. Version 2.0

EUCIP - IT Administrator. Module 3 LAN and Network Services. Version 2.0 EUCIP - IT Administrator Module 3 LAN and Network Services Version 2.0 Module 3 Goals Module 3 Module 3, Local Area Network and Network Services, requires the candidate to be familiar with the procedure

More information

CREATING YOUR OWN RF SWITCHING SYSTEM

CREATING YOUR OWN RF SWITCHING SYSTEM AN2008-08-YOM rev. 2.0 By Sara Nazemzadeh April, 20 Application Note REATING YOUR OWN RF SWITHING SYSTEM Abstract The purpose of this Application Note is to introduce an alternative way of meeting switching

More information

Modbus and ION Technology

Modbus and ION Technology 70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible

More information

KNX Lighting Control System

KNX Lighting Control System KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting

More information

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov. Slide Number 1

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov. Slide Number 1 Nathan Dayton SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov Slide Number 1 NETWORK DESIGN Slide Number 2 Previously there have been two phases in the design of a network Department Design Interconnect Design

More information

Plena Voice Alarm System. Software Manual Configuration Software

Plena Voice Alarm System. Software Manual Configuration Software Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security. Cisco Small Business Access Points

Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security. Cisco Small Business Access Points Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security Cisco Small Business Access Points Advanced, High-Performance Wireless Access for the Small Business Highlights Supports high-bandwidth applications

More information

Multi-Homing Dual WAN Firewall Router

Multi-Homing Dual WAN Firewall Router Multi-Homing Dual WAN Firewall Router Quick Installation Guide M73-APO09-400 Multi-Homing Dual WAN Firewall Router Overview The Multi-Homing Dual WAN Firewall Router provides three 10/100Mbit Ethernet

More information

Process Control and Automation using Modbus Protocol

Process Control and Automation using Modbus Protocol Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

Laboratory Course Industrial Automation. Experiment Nr. 6. Introduction to the FlexRay bus system. Brief User Guide IAS Demonstrator Go-Cart

Laboratory Course Industrial Automation. Experiment Nr. 6. Introduction to the FlexRay bus system. Brief User Guide IAS Demonstrator Go-Cart Universität Stuttgart Institut für Automatisierungs- und Softwaretechnik Prof. Dr.-Ing. M. Weyrich Laboratory Course Industrial Automation Experiment Nr. 6 Introduction to the FlexRay bus system Brief

More information

Planning BACnet networks

Planning BACnet networks Digital Designer s Guide Application Note AN0404A Revision B About this application note Related reference materials Required software This application note describes the principles behind planning a BACnet

More information

DSX Master Communications

DSX Master Communications DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

Communication Setup Application Note

Communication Setup Application Note Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

Turbovex TX Modbus configuration guide

Turbovex TX Modbus configuration guide Turbovex TX Modbus configuration guide Side 1 af 12 1.0 Table of content TURBOVEX TX MODBUS CONFIGURATION GUIDE...1 1.0 TABLE OF CONTENT...2 2.0 GENERAL INFORMATION...3 3.0 MODBUS PRINT INSTALLATION...4

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

GE Security. FHSD Monitor / Web Server user manual

GE Security. FHSD Monitor / Web Server user manual GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the

More information

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking Ethernet-based communication, Transmission Control Protocol/Internet Protocol (TCP/IP), is emerging at all levels of the mass communications market. The introduction of Power-over- Ethernet (PoE) is poised

More information

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's

More information

Product Scope. Hardened Ethernet. Commercial Ethernet. Extended Ethernet. Wireless Ethernet. Fibre Optic Twisted Pair Coaxial Telephone Wireless

Product Scope. Hardened Ethernet. Commercial Ethernet. Extended Ethernet. Wireless Ethernet. Fibre Optic Twisted Pair Coaxial Telephone Wireless Product Review Product Scope Hardened Ethernet Commercial Ethernet Extended Ethernet Wireless Ethernet Fibre Optic Fibre Optic Twisted Pair Coaxial Telephone Wireless Where do we work? Unconditioned Environments

More information

Connecting to the network

Connecting to the network 5 Connecting to the network This chapter discusses the basic stages of connecting the printer to the network, provides an overview of network requirements and protocol diagrams, and describes how to physically

More information

Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1

Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1 Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...

More information

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Deploying Windows Streaming Media Servers NLB Cluster and metasan Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................

More information

POS Integration. Prepared by: Binh Nguyen

POS Integration. Prepared by: Binh Nguyen POS Integration Prepared by: Binh Nguyen Point of Sale (POS) Compatibility To know whether it is possible to integrate your POS system with our DVR, please check whether the type of printer the POS system

More information

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring Siemens Integrated Substation Condition Monitoring System Circuit Breaker Monitoring System Description Introduction The Circuit Breaker Monitor [CBM] is only one example of the way that the Substation

More information