Thermal insulation with Elastopor H spray foam
|
|
|
- Aron Miles
- 9 years ago
- Views:
Transcription
1 Thermal insulation with Elastopor H spray foam
2 List of contents Page Background information 3 Climate protection and energy savings 4 Overview of applications 5 Key advantages 6 Technical data 7 External wall: Internal insulation 8 External insulation and render system 9 External insulation between masonry walls 10 External insulation behind cladding 11 Internal insulation in timber frame wall construction 12 Pitched roof: Internal insulation between the rafters 13 External roof insulation over the rafters 14 Insulation on solid pitched roofs 15 Flat roof: Insulation on solid flat roofs 16 Insulation on lightweight industrial flat roofs 17 Floor structure: Insulation of the loft/attic floor 18 Floor: Insulation of floors with underfloor heating 19 Basement ceiling: Insulation of basement ceilings/soffit 20 Agricultural buildings: Internal insulation of livestock and agricultural buildings 21 Case studies 22 Contact 23
3 Leading position in the industry The Elastogran Group is one of the leading companies in the field of the speciality polyurethanes (PU). This subsidiary of BASF has over 40 years of expertise in polyurethanes and its headquarters in Lemförde, Germany, is the international technology centre for BASF s polyurethanes business. This dynamic market and technology leader in PU specialities, has virtually the full range of polyurethane products in its portfolio. spray foam systems are approved by the top building inspection authority in Berlin, the Deutsches Institut für Bautechnik (DIBt). Other European and non-european countries will have their own separate local approvals. Cooperation and convenience for the customer In the European Economic Community, Elastogran runs BASF s PU business through a series of local system houses which can offer a rapid response to developing individual solutions via technical service, sales and marketing. BASF s leading position in the market of manufacturing polyurethane basic products is underpinned by large-scale plants in all regions of the world. Its close links with BASF, the world s leading chemical company, means that Elastogran, as part of the worldwide BASF Verbund can tap into global resources for research, supply of raw materials, sales, finance and especially environmental protection. Working on the principle We help our customers become more successful, Elastogran develops individual, customised solutions and also creates its own innovative product applications. Elastogran has initiated numerous projects in partnership with its customers, both in the form of new products and also with specific developments in new fields of application. This is Elastopor H Elastopor H spray foam is a closed-cell, rigid polyurethane foam. This is produced by an exothermic reaction between a polyol component and an isocyanate. At the end of the reaction phase, the foam begins to solidify and cure. Applied with a spray gun in several layers, provides seamless thermal protection. The field of application covers virtually all areas of flat and pitched roofs, ceilings, walls and floors.
4 Climate protection and energy savings Climate change is one of the major industrial challenges of our time. Business, science, politics and industry are being called upon to slow down any further rise in greenhouse gas emissions and use available resources more efficiently. It is clear to everyone today that there is a finite limit to fossil fuel sources. Natural gas has recently become a focus of speculation. Faced with these facts, various concepts and strategies for sustainable protection of the environment and climate, for the future, have been put forward. A key approach is improving thermal insulation in buildings. A concern for property owners is energy conservation measures and the costs entailed. The technologies and materials required, have been available for some time and can be very cost effective. In many cases, investing in thermal insulation measures pays for itself in less than ten years, and in many countries grants and attractive loans are being given. Get on board! Thermal insulation of buildings New and old buildings are today and will be in the future very largely subject to energy saving and environmental protection requirements. The focus here is on thermal insulation and sealing of buildings and roofs. From a structural point of view, roofs are the most exposed parts of a building. They have to withstand heat and cold, wet and dry conditions, storms and snow, and even decades later still be water-tight and provide reliable thermal insulation. represents up-to-date, environmentally- and energy-aware and economic insulation. Energy certification of buildings The Kyoto Protocol has put pressure on the industrialised countries to reduce emissions of greenhouse gases. According to the EU directive, energy certification aims to create incentives to carry out renovation measures. It gives information on the energy rating of buildings and is intended to be given to potential buyers or people renting property for construction, purchase or rental purposes. Country example:
5 External insulation on solid pitched roofs (page 15) External roof insulation over the rafters (page 14) Internal insulation between the rafters (page 13) Insulation of the loft/attic floor (page 18) Insulation and render system (page 9) Internal insulation in timber frame wall construction (page 12) Insulation on solid flat roofs (page 16) Insulation of floors with underfloor heating (page 19) Internal insulation of livestock and agricultural buildings (page 21) Insulation on lightweight industrial flat roofs (page 17) Internal insulation with facing wall (page 8) Insulation of basement ceilings/soffit (page 20) External insulation behind cladding (page 11) Internal insulation with curtain wall (page 8) External insulation between masonry walls (page 10) Versatile insulation with systems are produced directly on the substrate to be insulated using a pouring or spray process. The material forms a continuous, even insulating layer with no joints or gaps, eliminating any thermal bridges. Spray foam is the ideal solution for a very wide variety of surfaces and shapes because the material adapts to any profi le without gaps. The versatile options for using, range from insulating fl at roofs in new buildings through fl at and sloping roof renovation in old buildings and commercial premises. The range of application is not just restricted to the external insulation of roofs. Its application properties also make suitable for installation on the underside of roofs. The same applies for internal, external and cavity insulation of external walls, basement ceiling and soffi t insulation. The installation method of the system is the same for internal areas as for external insulation. A comparison with conventionally insulated roofs and walls, clearly shows that is more cost-effective to produce and with the same layer thickness, has a much better thermal conductance than other insulating materials. The closed cell structure means that is waterresistant and at the same time provides a seal against the effects of weathering and temperature. A UV protective membrane is applied as an external coating for fl at or pitched roofs. 5
6 Key advantages at a glance Insulation with no joints or gaps Maximum insulating performance at minimum thickness Insulation of components in hard to treat areas Excellent adhesion to the substrate Prolongs the life of buildings Rapid installation times Safe, professional installation Increases comfort in the home Low material weight Quality assurance through self-monitoring Easy to transport and store Spray application of insulating material produces a seamless insulating layer with no joints or gaps and reduces energy loss due to thermal bridging. has an extremely low thermal conductivity not achieved by any other conventional insulating material, saving valuable space. Liquid installation means that critical, inaccessible or curved areas can be insulated without any problem no need for laborious cutting and fitting. fits like a second skin and is suitable for virtually all substrates such as corrugated fibre cement, profiled metal sheet or timber boards. rigid, robust, closed-cell foam demonstrably improves the construction and life of buildings. An experienced installation team can treat many m² of roof area a day with a foaming unit, when conditions are favourable. Trained, qualified people from certified installation companies guarantee safe, accurate application of the spray foam. Residents of buildings insulated with report an improved indoor environment and a greater degree of comfort. s low weight places very little stress on components, making it safer for example when there is heavy snow on flat roofs. Elastogran is certified to BS EN ISO 9001, ISO/TS 16949:2002 and BS EN ISO Each batch is checked and tested before delivery. The relevant countries have local product certifications for. is foamed as a liquid mixture on site which means rapid transport and space-saving storage at the site. Economic insulation
7 General technical information s excellent technical physical properties mean it is very versatile. With a maximum aged thermal conductivity (l) of W/(m K), thin insulating layers can be produced with. is frost- and heat-resistant from -50 C to +100 C. is resistant to heavy acids and alkalis, seawater, industrial waste gases and aliphatic hydrocarbons (mineral oil, petrol, diesel fuel, etc). Further technical information, approvals, data sheets and specifications are available on request from Elastogran. Key physical and technical features Properties Low foam density High foam density Unit Standard Application Wall / roof Floor / patio / roof capable of withstanding foot traffic Density kg/m³ EN 1602 Long-term water absorption < 2 < 2 % EN Closed cell structure > 90 > 90 % ISO 4590 Fire performance construction material class * E E EN Thermal conductivity l (design value) 0,028 0,028 W/(m K) EN Impermeability to water (at 0.6 bar) waterproof waterproof EN 1928 Compressive strength (10% compression) 0,15-0,20 0,20-0,40 N/mm² EN 826 * E = standard value; other systems available with a higher level of fire protection.
8 External wall Internal insulation with Insulation on the inside of external walls is the best solution if insulation from outside is not an option. Even older buildings with listed facades or those worth preserving often have low thermal insulation which can be improved by more than 60% by internal insulation. Installation is also comparatively costeffective because no scaffolding is required for the building and it can be applied on a room by room basis. Since the internal surface temperature of the wall is increased by approx. 2 to 4 degrees, this has a positive effect on the indoor climate. insulating material is easy to apply to the inside of the external wall using the spray foam process. After a short curing time, the insulating layer is cladded on the room side using plasterboard or timber boards, decorative exposed brickwork or plastered brickwork. Comparatively little living space is lost due to the excellent insulating performance of even a thin layer of. Render Masonry Plasterboard curtain wall Floor structure Thermal bridge insulation internal insulation Facing wall flexible internal wall design rooms heat up rapidly vapour barrier not absolutely necessary comparatively little loss of space External wall with internal insulation and a lightweight or solid facing wall The installation of a vapour barrier must be checked in line with structural, climatic or regional conditions and building!regulations. Wall structure Thermal conductance U-value W/(m 2 K) with * Perforated brick 240 mm, thermal conductivity l = 0.50 W/(m K) without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm Internal plasterboard curtain wall 1,41 0,47 0,35 0,28 0,23 0,20 0,18 Internal facing wall 60 mm 1,26 0,45 0,34 0,27 0,23 0,20 0,17 8
9 External wall External insulation and render system with External walls are normally the largest external surface area of buildings through which heat can escape virtually unchecked. Between 100 and 150 kilowatt hours of heating energy are lost through one square meter of uninsulated wall per year, corresponding to approximately 10 to 15 litres of heating oil or 10 to 15 cubic metres of gas. This can be reduced by up to 90% with external thermal insulation. high thermal insulation spray foam is applied directly to the dust-free wall at specifi c points without a primer. A special primer plaster is applied directly to the cured insulating layer as an adhesion promoter for the fi nal decorative render system. Dowelling of the insulation or incorporation of a fabric layer required with conventional systems is not required. Decorative render system Primer plaster external insulation Masonry Floor structure time- and cost-saving installation reinforces the wall construction insulating layer with no thermal bridge Masonry with external insulation and render system individual design with decorative plaster Wall structure Thermal conductance U-value W/(m 2 K) with * Perforated brick 240 mm, thermal conductivity l = 0.50 W/(m K) The internal plaster is not considered thermal insulation. without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 1,54 0,48 0,36 0,29 0,24 0,20 0,18 9
10 External wall External insulation between masonry walls with Many buildings are designed with double skin masonry for visual or structural reasons or as protection against extreme weather conditions. The cavity is given an insulating layer so that the cold air between the facing wall and the lining wall does not then cool the external wall and therefore have a negative effect on the energy consumption of the building. The PU foam is applied to the external wall in layers with no joints. The substrate must be dry and dust-free for the insulation material to adhere securely. The facing wall made of for example clinker bricks, quarry stone or plastered masonry forms the outer exposed cladding and at the same time serves as a protective layer. Normally there is a 3 to 4 cm air gap between the insulation and the facing which dries off any penetrating moisture or rainwater. pouring system can also be injected through small holes drilled in the masonry. This fully fi lls the cavity, bonding the two leaves together. This can be used to overcome any structural problems in combination with the best cavity wall insulation on the market, thickness for thickness. safe protection of the fabric of the building Outer skin Air gap external insulation Masonry Floor structure Double skin masonry with core insulation and air gap individual design of the facade weather-resistant and rot-proof moisture-resistant Wall structure Thermal conductance U-value W/(m 2 K) with * Perforated brick 240 mm, thermal conductivity l = 0.50 W/(m K) Outer skin and air gap The internal plaster is not considered thermal insulation. without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 1,28 0,45 0,34 0,28 0,23 0,20 0,17 10
11 External wall External insulation behind cladding, using The external insulation behind a curtain wall or with ventilated cladding can be used both in new buildings and refurbishment of existing buildings. The cladding protects the external components against weathering and as a decorative facade gives a designer, lots of options Metal supports for the cladding are prefi xed to the wall then is sprayed onto the wall and around these fi xings. Depending on the type of cladding, a system of vertical timber laths or aluminium support rails are then installed to attach the curtain wall. There should be a 2 to 4 cm ventilation gap between the curtain wall and the insulation to dry off any moisture that occurs in this area. good weather protection for the external walll versatile facade design increases comfort in the house no problems with moisture Curtain wall with support construction Air gap external insulation Floor structure Masonry External wall with thermal insulation and curtain ventilated cladding Wall structure Thermal conductance U-value W/(m 2 K) with * Perforated brick 240 mm, thermal conductivity l = 0.50 W/(m K) Curtain wall and air gap The internal plaster is not considered thermal insulation. without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 1,51 0,48 0,36 0,28 0,24 0,20 0,18 11
12 External wall Internal insulation in timber frame wall construction using Timber frame construction is typical in Great Britain, USA and Canada. As the name suggests, this method of construction relies on a timber frame as a basic means of structural support. The outer leaf is typically stone, brick, render or timber, to suit the local district or planning requirements. is applied between the studwork of the timber frame for thermal insulation. The low thermal conductivity of the material has clear advantages here because despite low wall thicknesses, a comparatively high insulating performance is achieved. The cured spray foam guarantees additional support and stability for the whole of the timber frame construction. The in-situ application of the foam also guarantees air tightness of the structure, something traditional insulation methods cannot do. There must be an air gap between the external facing and the insulated timber frame for ventilation. Outer skin Air gap Breather membrane Board Insulation with Timber frame Foil backed plasterboard space-saving wall construction rapid assembly and insulation individual facade design Timber frame construction with thermal insulation between studwork and ventilated outer skin (horizontal section) guaranteed air barrier Wall structure Thermal conductance U-value W/(m 2 K) with * Plasterboard cladding Timber studs 60 / 100 or bigger, spacing e = 62.5 cm, timber 9.6% timber formwork Outer skin with air gapußenschal 60 mm 70 mm 80 mm 90 mm 100 mm 120 mm 140 mm 0,43 0,38 0,35 0,32 0,30 0,26 0,23 1
13 Pitched roof Internal insulation between the rafters with In times of rising energy costs and shortage of living area, loft conversions are becoming increasingly popular. can be applied from inside the loft space without the need for re-roofi ng, adding another room to the house, cost effectively. Since the rafters of existing homes are normally only 10 to 14 cm thick, the thickness of insulation with conventional material between the rafters is often not enough to meet today s thermal insulation requirements. s extremely low thermal conductivity and high insulating performance with a low thickness, means there is no need to extend the depth of rafters which is costly in terms of both time and money. Using the proven Elastogran spray foam process, is simply sprayed between the timber rafters without the need for laborious cutting and fi tting. This produces a solid, air tight foam layer, with a high thermal insulation effect without energy wasting joints that occur when normal insulation materials are laid. Roof cladding on support construction Roof rafters Breather membrane insulation delete ADD prevents air leakage seamless insulation reducing thermal bridges no laborious cutting and fitting of the insulating material rapid installation not dependant on weather conditions Rafter roof with membrane and internal between-rafter insulation The installation of a vapour barrier must be checked in line with structural, climatic or regional conditions and building!regulations. Roof construction Thermal conductance U-value W/(m 2 K) with * Between-rafter insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 160 mm 180 mm Roof rafters 8 / 16 Spacing e = 70 cm, timber content 11.4% Top roof skin 19 mm 0,61 0,46 0,37 0,31 0,27 0,24 0,22 0,20 The air gap and roof construction above the roof skin are not considered thermal insulation. 1
14 Pitched roof External roof insulation over the rafters using Over-rafter insulation means thermal insulation above the rafters. The insulating material is applied to the roof rafters from outside and only then is the roof covered the rafters and roof board can still be visible from inside the room. Over-rafter insulation is an advantage if energy conservation and re-roofi ng are required. Ideal for attic rooms and loft conversions As with solid roof insulation, insulating material is applied directly to the board attached to the roof rafters. Since the external insulating layer is exposed to extreme variations in temperatures, the dimensional and volume stability of helps prevent any cracks or deformations occurring. Roof cladding on support construction Roof rafters insulation Roof skin jointless, full cover thermal insulation thermal bridge-free insulation no disturbance during installation high insulating performance due to variable thickness of insulating material Rafter roof with visible rafters,top roof skin and external thermal insulation The installation of a vapour barrier must be checked in line with structural, climatic or regional conditions and building!regulations. Roof construction Thermal conductance U-value W/(m 2 K) with * Over-rafter insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 160 mm 180 mm Roof rafters 8 / 16 top roof skin 21 mm 0,58 0,41 0,32 0,26 0,22 0,19 0,17 0,13 The air gap and roof structure above the thermal insulation layer are not considered thermal insulation. 1
15 Pitched roof Insulation on solid pitched roofs using Solid roofs are basically composed of sloping external walls with all the associated structural properties. The roof is quickly assembled from prefabricated units on site by the manufacturer and virtually any shape of roof is possible. Since solid roofs normally consist of concrete, they have primarily fi re and acoustic insulation benefi ts. They provide an effective screen for street and aircraft noise and ensure maximum fi re resistance. Other aspects are a high level of safety in the event of storms and thermal insulation in summer. This provides a pleasant living environment under the roof as a result of the external insulation of the rooms. Elastogran s spray foam is spray-applied simply, quickly and straightforwardly to the dry, dust-free surface of the roof. No vapour barrier between the solid roof and the insulating layer is required. Roof cladding on support construction insulation Solid roof pleasant indoor climate thermal insulation in summer improved noise and fire protection Solid pitched roof with external thermal insulation thermal bridge-free roof construction The installation of a vapour barrier must be checked in line with structural, climatic or regional conditions and building!regulations. Roof construction Thermal conductance U-value W/(m 2 K) with * Solid roof / reinforced concrete 160 mm, Thermal conductivity l = 2.10 W/(m K) 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 160 mm 200 mm 0,61 0,42 0,33 0,26 0,22 0,19 0,17 0,14 The air gap and roof structure above the thermal insulation layer are not considered thermal insulation. 15
16 Flat roof Insulation on solid flat roofs using Flat roof coatings in new and existing buildings, is one of the main areas of application for PU spray foam. Insulating fl at roofs places high demands on the insulating material because roof areas have to withstand very different conditions such as extreme variations in temperature and exposure to snow, wind and rain. UV protective layer insulation Solid roof Coating the roof with has been proved to produce up to 80% savings in time and up to 50% in investment costs compared with conventional insulating methods. Particularly critical areas and those diffi cult to access on domed areas or parapets can be easily insulated. Even existing old bitumen-treated felt roofi ng can be easily sprayed over. The insulating foam cures very quickly and can be walked on after a few minutes. A UV protective layer from a range of recommended membrane coating products is then applied. simple, seamless insulation of critical areas suitable for virtually all substrates economic due to rapid treatment fl at roof with external thermal insulation and UV protective layer durable and rot-proof The installation of a vapour barrier must be checked in line with structural, climatic or regional conditions and building!regulations. Roof construction Thermal conductance U-value W/(m 2 K) with * without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 160 mm 200 mm Solid ceiling / reinforced concrete 160 mm, Thermal conductivity l = 2.10 W/(m K) The internal plaster is not considered thermal insulation. 4,49 0,61 0,42 0,33 0,26 0,22 0,17 0,14 1
17 Flat roof Insulation of lightweight industrial flat roofs using As with the insulation of solid fl at roofs, thermal insulation of industrial roofs is one of the traditional applications of. Roofs of warehouses, production facilities, exhibition and sports halls are normally made of profi led metal sheet and have relatively large spans. These lightweight roof constructions require a lightweight insulating material to be able to take the additional loads produced by snow, wind and rain. UV protective layer insulation Trapezoidal metal sheet roof construction Support construction Because of its in-situ installation properties, can be applied to the metal sheet profi le seamlessly, coating both the peaks and troughs in the profi le. The insulating layer then only needs to be provided with UV protection. Vapour barriers, sloping screeds or other additional materials are not normally needed, saving valuable time and money. low weight of the insulating foam adapts to any profile without gaps large areas can be treated in just one day high compressive strength, dimensionally stable Trapezoidal metal sheet roof with external insulation and UV protective layer Roof construction Thermal conductance U-value W/(m 2 K) with * without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm Trapezoidal metal sheet 6,83 0,64 0,44 0,33 0,27 0,23 0,19 1
18 Floor structure Insulation of the loft/attic floor using Thermal insulation of the ceiling of a concrete framed building is the most simple and cost effective solution in energy conservation, if the top fl oors of the building are occupied. This is assuming the roof void remains unheated or not converted into living quarters. can be applied to the loft fl oor, directly onto the substrate, provided it is clean and dry. The Elastogran spray foam can be installed in areas diffi cult to access and the in-situ process seals all penetrations through the fl oor occurring near chimneys or pipes. If the loft space is exposed to foot traffi c, for example for maintenance work or used as storage space, chipboard can be loose laid over the top. no airtight flat area (vapour barrier) necessary cost-effective to install Roof construction ceiling insulation Thermal bridge insulation Top fl oor structure adapts to the substrate without gaps no ventilation of the insulating layer Insulation to the fl oor of an unheated loft/attic space Floor structure Thermal conductance U-value W/(m 2 K) with * Reinforced concrete ceiling 160 mm, thermal conductivity l = 2.10 W/(m K) without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm 3,62 0,59 0,41 0,32 0,26 0,22 0,19 18
19 Floor Insulation on top of ground floors with underfloor heating using Thermal insulation above the fl oor slab is advisable where underfl oor heating is installed. The insulating layer separates the heated and unheated areas inside a building and in this way reduces any loss of valuable heating energy. Even with rooms only used occasionally, insulation on top of fl oors with underfl oor heating has benefi ts because the cold fl oor heats up more rapidly and no heat is passed into the fl oor slab. As with roof void insulation, spray foam is simply sprayed on to a dry, dust-free base. Foam can be applied quickly and easily to pipes, water, heating and electrical installations. After a brief curing time, the screed and heating pipes are laid, the screed layer being separated from the insulation by a sheet. Screed Underfl oor heating Separating sheet ceiling insulation Floor structure The high compressive strength PU foam guarantees a secure substrate with excellent insulating performance even when subjected to permanent stress. insulation subjected to permanent stress deformation and compression-free Insulation under the heating screed thin insulating layer with high insulating performance comparatively thin floor structure Floor structure Thermal conductance U-value W/(m 2 K) with * Heating screed 60 mm, concrete ceiling 160 mm, thermal conductivity l = 2.10 W/(m K) without insulation 40 mm 60 mm 80 mm 100 mm 120 mm 140 mm to the unheated basement 2,18 0,53 0,38 0,30 0,25 0,21 0,18 bordering on to soil 3,46 0,58 0,41 0,32 0,26 0,22 0,19 19
20 Basement ceiling Insulation of basement ceilings/soffit using Cold ground fl oors of a building occur if the soffi t is not insulated against the unheated basement. The low temperatures in the concrete soffi t can lead to high energy losses, interstitial condensation and even the formation of mould. This problem can easily be resolved by insulating with. The Elastogran spray foam system can be applied to most soffi ts, without costly access equipment. The material is self-adhesive and requires no labour intensive cutting and fi xing. Water pipes and electrical cables can easily be hung beneath the insulation. Any uneven areas such as old vaulted basements, ribbed or waffl e shaped soffi ts, can be rapidly and economically insulated using. The insulation is seamless compared to conventional insulating methods, so there is no risk of cold air penetrating through the ceiling and creating heat loss. Render Masonry Thermal bridge insulation Floor structure / basement ceiling basement soffit insulation inhibits mould formation suitable for uneven areas and vaulted ceilings no drilling and fixing Soffi t insulation for unheated basements seamless insulation under pipes or installations Ceiling structure Thermal conductance U-value W/(m 2 K) with * Concrete ceiling 160 mm, thermal conductivity l = 2.10 W/(m K) without insulation 40 mm 50 mm 60 mm 70 mm 80 mm 90 mm 100 mm 2,40 0,54 0,45 0,39 0,34 0,31 0,28 0,25 0
21 Roof and wall Internal insulation of livestock and agricultural buildings using Agricultural buildings such as stables, barns and crop stores are exposed to major stresses. Transpiration and excretions from animals, exhaust fumes from agricultural vehicles and high levels of humidity and condensation affect the building construction, along with external weather conditions such as storms, rain, snow, hail and heat. A potential insulation for agricultural purposes should be durable, resistant and of course cost-effective. spray foam caters for all possible external geometries and insulates the roof both from inside and from outside. The cured material provides effective protection from draughts and strengthens the building through the compact, jointless insulating layer. has a positive effect on the life and value of the fabric of the building. Fibre cement corrugated sheet / profi led steel insulation prevents condensation adapts to any shape without joints reinforces the building construction inert material Internal roof and wall insulation of agricultural buildings rapid, economic application saves energy costs Wall construction Thermal conductance U-value W/(m 2 K) with * Roof construction without insulation 40 mm 50 mm 60 mm 70 mm 80 mm 90 mm 100 mm Roof: fibre cement corrugated sheet 7,14 0,64 0,52 0,44 0,38 0,33 0,30 0,27 Wall: profiled steel 5,88 0,63 0,51 0,43 0,38 0,33 0,30 0,27 1
22 Case studies Elastogran s spray foam system has proved to stand the test of time due to its physical properties and economic installation. The following is a small selection from a large number of buildings successfully insulated using.
23 Contact You can contact the specialists in polyurethane system houses at BASF and Elastogran throughout the world. We are happy to give advice on the installation and application of spray foam. us any queries or requests you may have at the following address, stating the country where there is interest in using the spray system. We will forward your message to the appropriate Elastogran office and guarantee you a quick, straightforward reply. 23
24 Elastogran Headquarter Elastogran GmbH Elastogranstraße Lemförde Germany Phone: Fax: European Development Center Sprayfoam Elastogran S.A. Polígono Industrial Can Jardí Calle Vivaldi, Rubi (Barcelona) Spain Phone: Fax: GENERAL ENGLISH VERSION = registered trade mark of BASF SE
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
Waterproofing construction Joints
WaterproofingSystems Waterproofing construction Joints Area waterproofing Backing rod KÖSTER Joint Sealant FS-H KÖSTER FS Primer Contents Basics Connective, loadable and resilient: Joints in building construction
Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Mineral fibreglass insulation
Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS
HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS HIGH-QUALITY INSULATION. SUSTAINABLE LIVING. www.homatherm.com Preamble THE EXAMPLE OF NATURE Sustainable living to us means harnessing the forces of
Editorial. Table of contents. 1995 Neopor. 1951 Styropor
Wall insulation Table of contents Editorial 2 Neopor Innovation in Insulation 3 Overview of applications for Neopor 4 Applications for Neopor 5 Cavity insulation 6 Interior insulation 6 Exterior insulation
STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope
STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions
Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group
INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation
BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
Technical Data Sheet Art. No. 1810. Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product
Page 1 of 5 Technical Data Sheet Art. No. 1810 Kiesol Deep protection silicification for waterproofing and refurbishing old and new buildings in the Kiesol System according to WTA Code of Practice 4-4-04/D
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
OLDROYD. Interior Walls. Interior Walls. below and above ground. below and above ground
S S.doc.2 12/3/03 6:26 pm Page 1 Oldroyd produce a wide range of products to combat the problems of water ingress and dampness in buildings. Other brochures are available covering the following : We have
Avoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
WALLS Three common wall types are described below, with their insulation solutions.
APPENDIX 5: Building Envelope Insulation is vitally important for temperature controlled buildings. If fuel (and therefore money) is being used to heat a building, less fuel (and money) will be used if
12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com
AND MEMBRANES 010 ROOFING UNDERLAYS 1 HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays
We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview
http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about
Mold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
European Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org
Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
Sealing & Bonding Sika solutions for Window Installation
Sealing & Bonding Sika solutions for Window Installation Sika s Comprehensive Fenestration Competence Benefit of our solution Globally, growing requirements to save energy and to utilize natural resources
Chapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based. 0.028 W/mK BAUSTOFFE MIT SYSTEM
FIXIT.CH Aerogel Insulating Plaster System Handling Guidelines BAUSTOFFE MIT SYSTEM λ 0.028 W/mK Mineral based Easy to use Efficient building insulation using space technology Aerogel high-performance
Signs of insulation problems In the winter. In the summer. conditioning system
about your house CE 19 While previous generations may have been content to live in drafty houses, most people now want comfortable warm houses. A healthy house today is well sealed, well insulated and
Improving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
Advice to consumer Reference 50.1 May 2013. Condensation. Some causes, some advice.
Advice to consumer Reference 50.1 May 2013 Condensation Some causes, some advice. 03 Contents The issue 04 What is condensation 06 The factors governing condensation 09 How double or triple glazing helps
ProRox Slabs (formerly known as RW slabs)
Slabs (formerly known as RW slabs) Versatile thermal acoustic insulation slabs ROCKWOOL's Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are
The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.
26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central
Mineral waterproof coating PCI Dichtschlämme
Mineral waterproof coating PCI Dichtschlämme 305 for basement walls, swimming pools and potable water tanks With official test certificate. FIELDS OF For indoor and outdoor use. For walls and floors. For
SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO
SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO SIKA SYSTEMS FROM BASEMENT TO ROOF BASEMENT TO ROOF SOLUTIONS FOR ELEPHANT HOUSE AT ZURICH ZOO PROJECT DESCRIPTION The Kaeng Krachan Elephant
Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments
Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
Including. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
Wecryl Waterproofing System under surfacing supplied by others
Brief description The Wecryl waterproofing system allows a high-quality, seamless and crack-bridging waterproofing layer to be installed under loose-laid or bonded surfacing supplied by others (stone slabs,
Building Control Guidance Note
Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
Rainwater Harvesting
Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth
Introduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
Steel-framed Walls. Insulation
Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable
Airtight Intelligence
VARIO - Airtight Intelligence The multitasking membrane The Vario System keeps heat in Airtight Intelligence Vario-System keeps draughts out beats present and future regulations saves energy Introducing
CREATING EFFECTIVE WATERPROOFING & DRAINAGE FOR INTERIOR WALLS. Using Oldroyd Xv clear, Xv20 and Xp on interior walls
CREATING EFFECTIVE WATERPROOFING & DRAINAGE FOR INTERIOR WALLS Using Oldroyd Xv clear, Xv20 and Xp on interior walls Oldroyd cavity drainage membranes provide a simple and cost effective solution for dealing
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
Development of conservation compatible new materials for envelope retrofitting of historic buildings
Development of conservation compatible new materials for envelope retrofitting of historic buildings Carsten Hermann, Senior Technical Officer, Historic Scotland Glasgow is one of seven EFFESUS case study
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
ROOFS, SNOW AND ICE DAMS
ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof
ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.
Rigid, Semirigid and Flexible Slabs Versatile thermal acoustic insulation slabs ROCKWOOL are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are manufactured
TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation
Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
WOOD FLOORING ADHESIVES
dispersion adhesive 2 component adhesive MS polymer adhesive WOOD FLOORING ADHESIVES PROFESSIONAL PRODUCTS SOUDAL, leading adhesive manufacturer WOOD FLOORING ADHESIVES Soudal NV, located in Turnhout (B)
Concrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
Safeguard Waterproofing Systems. Creating useable. living space. by making basements dry
Safeguard Waterproofing Systems living space Creating useable by making basements dry The SWS waterproof cement system The Safeguard SWS Structural Waterproofing System is designed to be both highly effective
201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE
STRUCTURAL INSPECTION REPORT DRAFT 201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE TOWN OF PRESCOTT Date: November 2013 GENIVAR No.: 131-20617-00 2611 Queensview Drive, Suite 300, Ottawa,
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render
BEST PRACTICE GUIDE Fibrelime Premixed Universal Plaster and Render Contents: Fibrelime description Fibrelime suitability Preparation before application Application Aftercare Painting General Recommended
STENCA PIPE. High quality pipe insulation. www.stenca.com
STENCA PIPE High quality pipe insulation WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
Building Regulations for the Conservation of Fuel and Power
Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction
Asbestos Encapsulation Solutions
Asbestos Encapsulation Solutions Eliminate your Asbestos problem quickly, safely, effectively and at an affordable price, with SealPro Sealants and Coatings SealPro ACM-REPELLO - and or ACM-SUPABOND (
Comment Form on Proposed Gut Rehabilitation Alternatives
Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION David Marut TEST CASE REPORT July 1, 2014 Case Study Pro Guard EPDM Super Coat Liquid Rubber Membrane Roof System
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form
Construction Product Data Sheet Edition 15/07/2013 Identification no: 01 07 05 04 001 0 000001 Sika 1 Pre-Bagged Structural Waterproofing System Product Description Pre-Bagged Structural Waterproofing
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.
kalox-pool draft 231 KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete. repairing refurbishing and finishing 8-30 C Trowel / Spray 4 mm kalox-pool EN 1504-2 MAIN FEATURES
Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane
Section Flat Roofs Warm deck single ply membrane Product: Rocksilk Krimpact Flat Roof Slab Fl01 Warm deck single ply membrane Product: Polyfoam ECO Roofboard Fl02 Warm deck built-up felt/ mastic asphalt