Air separation and dirt removal equipment

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Air separation and dirt removal equipment"

Transcription

1 ir separation and dirt removal equipment Literature ref: 4/2 RGISTRD UKS QULITY MNGMNT S N ISO 91 Certificate No: FM 49 Flamco UK Limited Unit 4, St. Michael s Road, Lea Green Industrial state, St. Helens, Merseyside W9 4WZ. Telephone: Fax:

2 ir separation and dirt removal equipment ir in heating and air conditioning systems Henry's law in a cooling system mount of air liberated from the water 5 P Temperature pressure. When the temperature of water at constant pressure is raised, for example from to 2 O C, Henry's law can be used to determine the amount of dissolved air which is liberated from the water. mount of air liberated from the water 75 4 P Temperature 2.2 pressure 2 Lowering the pressure of the water at constant temperature also results in dissolved air being liberated. Henry's law in a central heating system. mount of air liberated from the water When the temperature of water at constant pressure is raised, for example from 2 to O C Henry's law can be used to determine the amount of dissolved air which is liberated from the water. mount of air liberated from the water Temperature pressure Temperature pressure Lowering the pressure of the water at constant temperature also results in dissolved air being liberated. 2 The presence of air in heating and air conditioning systems causes the following problems: l Irritating noise. l Reduced heat transfer. l Corrosion. l Damage to circulating pumps. l Loss of efficiency. l Increased energy consumption. l High maintenance costs. Causes of air occuring in heating / air conditioning systems To overcome the above problems, it is necessary to analyse the causes of air being present in a system: l ir is present before filling the system. l ir is trapped in the system when filled. l ir is entrained in mains water when filling. l ir is dissolved in water when filled. The presence of air dissolved in water can be explained by reference to Henry's Law. This states that C = K x P where C = concentration of dissolved air. K = absorption factor (dependent on temperature). P = pressure. From the diagram (right) it is apparent that the amount of air which is dissolved in water, is dependent on temperature and pressure. ir dissolved in water is liberated when the temperature rises or the pressure falls. Henry's law in a cooling system C normal dm air per kg water T Temperature in C C pressure in bar absolute In cooling systems part of the air is dissolved in water and part is air bubbles. When the water (and air) runs through the system it encounters different temperatures and pressures. Henry's Law says that during these temperature /pressure fluctuations air is successively liberated from and dissolved in the water. Pressure has the largest influence on the formation of air bubbles in a cooling system. The largest air bubbles will appear in places with low pressure (the upper part of the system), this is therefore the best place to site a Flamcovent. The temperature of water in the coil decreases which means that part of the air bubbles will again dissolve in the water, it is therefore preferable to mount a Flamcovent before the coil. To prevent air bubbles causing pump damage due to cavitation, a Flamcovent should be installed before the pump. Henry's law in a central heating system Very high temperatures occur at the combustion chamber wall of the boiler. It is here that very small air bubbles will be liberated from water containing air. These so called 'microbubbles' will be redissolved elsewhere in the system where the temperature is lower, unless they are immediately removed. If the microbubbles are removed immediately upon leaving the boiler, the air free (unsaturated) water results. ir present elsewhere in the system can be dissolved (absorbed) in this water. This absorption effect is utilised to bind all the free air in the system and to vent it to the outside by the combination of the boiler and the Flamcovent. This venting process is continuous until eventually the water that remains is strongly unsaturated. C

3 Flexvent and Flexvent Super automatic air vents The Flexvent automatic air vent can be used in both open and sealed cooling and heating systems. Flexvent, excluding type 1/8 and type H, are supplied with a shut off valve. When the Flexvent is disconnected from the shut off valve, the valve will close automatically making it easy to exchange or clean without draining down. To operate, the red cap should be turned one revolution anticlockwise. Flexvent type H has a 9 O angled connection for mounting on a radiator. Flexvent type P incorporates an air intake preventer. Principle of operation The Flexvent float keeps the venting valve closed. When air is collected inside the float chamber, the water level inside the Flexvent will decrease and the venting valve will open. The collected air will escape through the venting valve and the water level inside the Flexvent will increase again, which in turn closes off the venting valve. This process is continuous as long as air is collected in the Flexvent. The air cushion in the upper part of the Flexvent protects the venting valve against pollution. When the pressure inside the system is decreased below the ambient pressure, for instance during draining, the Flexvent acts as a vent. Open Closed Flexvent installation Flexvents should be mounted in a vertical position where air is collected naturally in the system Flexvent The Flexvent Super is made of. The venting valve is incorporated in the air chamber so that damage from the outside is almost impossible. The air chamber is conical in shape. The advantage of this construction is venting valve venting valve that the clearance between the water level and venting valve is larger than in a straight chamber. For example if both straight and conical shaped chambers have the same height and bottom surface area, when the water level rises the pressure rise in the conical shape will be faster than the straight shape due to the smaller volume. Therefore the pressure balance in the conical shape will be reached at a lower water level. Dirt floating on the water in the Flexvent Super will remain clear of the venting valve in normal conditions. This means that fouling of the gearing and venting valve is reduced to a minimum. ø2 ø2 ø2 ø2 ø2 ø2 water level a water level Water level after filling the system a l/min bar flexvent max. bar max 12 C 1/8" SP Flexvent 1/8 65 flexvent 82 max. bar max 12 C /8" SP Flexvent /8 77 flexvent 88 max. bar max 12 C 1/8" SP Flexvent 1/8/8 /8" SP flexvent 82 max. bar max 12 C 1/2" SP Flexvent 1/2 flexvent max. bar max 12 C 9 /8" SP Flexvent P /8 flexvent max. bar max 12 C 9 1/2" SP Flexvent P 1/ flexvent H 6 51 Flexvent H 1/2 1/2" SP 119 flexvent super 1/2" SP 7 Flexvent Super l/min Flexvent Super bar Type Connection Max. Max. pressure Material temp. bar Flexvent 1/8 Flexvent /8 Flexvent 1/8/8 Flexvent 1/2 Flexvent P /8 Flexvent P 1/2 Flexvent H Flexvent Super Flexvent Super K22 1/8"(M) /8"(M) 1/8" and /8"(M) 1/2"(M) /8"(M) 1/2"(M) 1/2"(M) 1/2"(F) 1/2"(F) 12 O C 12 O C 12 O C 12 O C 12 O C 12 O C 12 O C 12 O C 12 O C nickel plated Shutoff valve no yes yes yes yes yes no optional optional

4 max. bar max 12 C Flexair air separators Flexair air separators can be used in sealed heating and cooling systems up to a maximum temperature of 12 O C and a maximum pressure of bar. The Flexair air separator is available in three different types: with threaded connections, with welded connections and with flanged connections. The connection dimensions conform to ISO standards. Principle of operation Operation of the Flexair air separator is based on the principle of centrifuge. Due to the tangential mounted connections, the water inside the Flexair is forced to rotate. This rotation forces the heavy medium the water against the wall of the Flexair while the air is collected in the middle of the Flexair. flexvent side view top view Mounted on top of the Flexair unit is a Flexvent air vent which will automatically discharge any air collected in the unit. Flexairs up to type 5 have a standard Flexvent and larger units are fitted with a Flexvent Super. Impurities which are heavier than water such as sand, weld debris etc., will collect in the bowl shaped lower section of the air separator. These impurities can be readily removed through the drain plug located at the base of the unit. Flexair air separators resistance diagram bar.5 kpa /4" 22ø 1"ø 1 1/4"ø 5ø 1 1/2"ø 65ø ø ø 125ø 15ø 2ø Pressure loss Flexair installation We recommend that the Flexair be connected to the suction side of the circulating pump on the flow Flow m /h

5 Flexair air separators ØD Flexair 1" 2" G Flexair 25 5 S Type Dimensions in mm Contents litres ØD F G Weight kg Flexair 1 G Flexair 1 1/4 G Flexair 1 1/2 G Flexair 2 G " 1 1/4" 1 1/2" 2" Flexair 25 S Flexair 2 S Flexair 4 S Flexair 5 S F F ød Flexair S ØD Flexair F G Type Dimensions in mm Contents litres ØD F G Weight kg Flexair 65S Flexair S Flexair S Flexair 125S Flexair 15S Sizes 2F to 6F are available to special order. Flexair 65F Flexair F Flexair F Flexair 125F Flexair 15F

6 Flamcovent microbubble air separators Flamcovent air separators are used for the virtual elimination of air from central heating and cooling systems up to a maximum temperature of 12 O C and a maximum pressure of bar. The principle on which Flamcovent air separators are based is a completely new method of removing gases from water the PLL ring process. (Patented). y applying this process, it is possible to remove: l l l air which is present in the system water in the form of small bubbles and microbubbles; air which is dissolved in the system water; air which is present where a Flamco automatic air vent cannot be installed. The Flamcovent air separator is available in two body types: Flamcovent with female thread or compression fittings and housing; Flamcovent with welded or flanged connection and steel housing. Operating principle of Flamcovent microbubble air separators Flamcovent air separators utilise the highly efficient and effective PLL ring method of removing gases from liquids. The PLL ring has been developed from the Raschig ring and has been used for many years in the processing industry. The use of PLL rings to remove air from central heating and cooling systems is however new. (Patented). The operating principle of the PLL rings results from the special properties which they possess, namely: l l l large surface area per m ; high probability of collision and adhesion; low resistance to fluid flow. Flamcovent and the coalescence effect The operation of Flamcovent air separators is based on the concept of coalescence. This means in practice that small air bubbles tend to adhere to a surface, and then grow together to form larger bubbles. When a stream of fluid flows past and through PLL rings, the stream is deflected in many different directions. The construction of the PLL ring is such that all the fluid is brought into contact with the total surface of the PLL ring that is available for adhesion. The microscopically small air bubbles present in the fluid attach themselves to the contact surface of the PLL ring. Once these microbubbles have grown to form larger bubbles, they can be separated from the fluid. The adhesion of of air bubbles after which they grow and become separable is known as 'coalescence'. large number of PLL rings are applied in the Flamcovent air separators, (from 115 in the smallest to 4 in the largest), so that a very large contact and adhesion surface is obtained.

7 Flamcovent microbubble air separators Construction of Flamcovent. 1. ir chamber. 2. rass housing.. Venting valve. 4. Float. 5. Gearing. 6. PLL rings. 7. Protective filter 5 6 Construction of steel Flamcovent. 1. ir chamber. 2. Venting valve.. Housing. 4. Flushing cock 5. Float. 6. PLL rings. 7. Drain valve COOLING SYSTM HTING SYSTM Operation The velocity with which water flows into the Flamcovent will be greatly reduced as a result of the enlargement of the flow passage. The larger air bubbles are thus given time and opportunity to rise upwards to the air chamber. t the same time, the stream of water collides with the many PLL rings present. s a result, very many small, evenly distributed currents are created in and around each PLL ring, so that all gas containing water particles are brought into contact with the entire PLL ring contact surface. ven the smallest microbubbles present in the water will adhere to the surface of the PLL ring. Since the stream of water in the Flamcovent comes to a complete standstill, the microbubbles can accumulate in the direction of the overlying chamber. The float mechanism and venting valve serve to expel the air separated from the water to the outside, and keep the volume of the air chamber constant. Construction Flamcovents are constructed from a vertical housing on which an air chamber is mounted. The housing contains the PLL rings which ensure a very large contact area with minimal resistance. The float, float mechanism and venting valve are located in the air chamber. The air chamber is conical in shape. Compared with a straight chamber this design ensures maximum clearance between the water and venting valve to prevent fouling of the mechanism. (See diagram ). dditional protection is given by the filter between the water and the air chamber. The larger steel Flamcovents (types 5 to 4) incorporate a flushing cock to eliminate floating impurities and may be used to release large quantities of air, for instance during filling. Impurities heavier than water will collect in Diagram. venting valve venting valve the lower bowl shaped part of the unit and these may be removed by means of the drain valve at the base. The venting valve is secured in the air chamber so that external damage is not possible. There is a facility to close the venting valve with the screw located in the outlet. Installation water level a Water level after filling the system Cooling systems ir bubbles that exist in the system will have a larger size before the coil than after. This is due to lower water temperature after the coil (Henry's law). Therefore in order to discharge the air as efficiently as possible, the Flamcovent should be installed in the flow circuit just before the coil. It should also be installed before the pump to prevent air bubbles from damaging the pump. It is recommended that a Flamcovent be installed on each floor above m. Heating systems Microbubbles which are liberated from the water in the boiler (high temperature) will be redissolved elsewhere in the system (lower temperature) if they are not immediately removed. Therefore in order to discharge air as efficiently as possible, the Flamcovent should be installed in the flow circuit immediately after the boiler or mixing valve. Install before the pump to prevent air bubbles damaging the pump and to prevent air bubbles being reduced to smaller bubbles by the pump's action. It is recommended that a Flamcovent be installed on each floor above m. water level When installed in existing boiler house with supply circuit directly beneath the ceiling, mount Flamcovent as above. For service purposes clearance '' should be at least mm. a

8 Flamcovent microbubble air separators Selection procedure (Heating and cooling systems) Flamcovent effectiveness depends on the system water speed. For best effect we advise a water speed of not higher than 1 1/2 m/s when installed in the optimum position (highest temperature, lowest pressure), and 1 m/s when it is not. If the Flamcovent is installed in a system with higher water speeds then adaptors must be fitted on inlet and outlet to decrease the water speed. The adaptors must divert no more than 4 O. with 1 1/2 m/s resp. 1 m/s in the entrance of the Flamcovent. xample: Flow capacity=7m/h. (refer to graphs below) ). Installed in the attic, max. allowable water speed 1 1/2 ms; select point (7m/h flow) and travel up to 1 1/2 ms curve (point ) and read to left for correct Flamcovent, in this case 125*. ). Installed in the basement, max. allowable water speed 1 ms; select point (7m/h flow) and travel up to 1 ms curve (point C) and read to left for correct Flamcovent, in this case 15* *lways choose the dimension nearest above the end point on the axis. Flamovent () 1 1/2" 1 1/4" 1" Ø22 /4" v= 1 m/s v=1 1/2 m/s Flamcovent Resistance Diagram Flow l/s Pressure loss kpa ø 22/4" 1" 1 1/4" 1 1/2"ø5 ø65 ø ø ø125 ø15 ø2 ø25 ø ø5 ø4 Flamovent (steel) Flow m /h v= 1 m/s v=1 1/2 m/s C Flow m /h

9 Flamcovent microbubble air separators Types and specification Type Dimensions in mm ØD S.O.J F G Contents litres Weight Kg Flamcovent Flamcovent 22 Flamcovent /4 Flamcovent 1 Flamcovent 1 1/4 Flamcovent 1 1/ /4" 1" 1 1/4" 1 1/2" Flamcovent welded connection Flamcovent 5S Flamcovent 65S Flamcovent S Flamcovent S Flamcovent 125S Flamcovent 15S Flamcovent 2S Flamcovent 25S Flamcovent S Flamcovent 5S Flamcovent 4S Sizes 5F and 6F are available to special order. Flamcovent flanged connection DIN 26 (ND 16) Flamcovent 5F Flamcovent 65F Flamcovent F Flamcovent F Flamcovent 125F Flamcovent 15F Flamcovent 2F Flamcovent 25F Flamcovent F Flamcovent 5F Flamcovent 4F ØD F rass Flamcovent (22 and /4 to 1.1/2) G Steel Flamcovent (Type S and F)

10 Flexcon S dirt interceptors unique range of high efficiency dirt interceptors for the removal of impurities from commercial heating and air conditioning systems. Specification Construction: Maximum working pressure: Maximum operating temperature: Insulation: Steel welded fabrication. 5 bar. bar available 12 O C. Optional extra. 2 7 Principle of operation 1 1. Reservoir. 2. Inlet.. Outlet. 4. Sludge pipe. 5. Isolating valve. 6. Perforation plate. 7. utomatic air vent Type Capacity Litres Dimensions in mm ød with ød insulation H Flow rate m /h Weight dry kg Flexcon S Flexcon S 1 Flexcon S 1 Flexcon S Flexcon S 4 Flexcon S 6 Flexcon S Flexcon S DN ød DN H 15 ød Flexcon S DN 25 Flexcon S with insulation.

11 Flamcovent Clean microbubble air separator with dirt chamber The Flamcovent Clean has been specially designed to separate solid particles as well as air from a heating and cooling installation. Practical experience and testing have shown that the PLL rings inside the Flamcovent will separate solid particles as well as air bubbles from the mainstream of the installation. The construction of the Flamcovent has been changed in such a way that in the enlarged bottom bowl a nonturbulent area is created. This allows relatively heavy particles to sink to the bottom of the Flamcovent Clean where there are no vortices to force the particles back into the system again. The collected particles can be drained from the system through the ball valve at the base of the unit. There are no PLL rings or obstacles in the bottom bowl to prevent the collected particles from being drained away. Lightweight solid particles that float in the water within the Flamcovent Clean can be drained out through the drain valve on the side of the body. The capacity of the Flamcovent Clean to separate solid particles from the system has been tested and reported on by the Dutch TNO Institute of nvironmental and nergy Technology (Report number R9564). The summary of the results and the conclusions of this report are shown below. The operating principle for air separation of the Flamcovent Clean is equal to the standard Flamcovent. For operating principle, selection criteria and technical data please refer to the Flamcovent air separator. TNO report TNO report Removal of suspended solids by the Flamcovent Clean Conclusion Removal of suspended solids by the Flamcovent Clean Table 5 Summary of results The Flamcovent Clean has a better performance in separating suspended particles than the conventional Flamcovent (compare TNOreport 9284). This holds for both fine and coarse particles. The removal efficiency of suspended particles increases with: decreasing flow velocity; increasing circulation fold; increasing settling velocity of particles, hence with larger and more dense particles. Flamcovent Clean proves to be well capable of removing suspended particles from a water circuit. Sand particles larger than 8 µm (or particles with a similar sedimentation behaviour) are removed well over 99% at a circulation fold of 5, using a flow rate of.5 m/s. lthough lower removal efficiencies are obtained at a flow rate of 1. m/s, still over 9% of the fine particles (8 6µm) and over 99% of the coarse fraction (212 25µm) is removed at a circulation fold of 5. xperiment number Flow rate (m/s) Circulation fold Overall (825µm) Removal efficiency (%) Fine fraction (86µm) Coarse (21225µm) Overall removal efficiency (%) Flow =.5 m/s Flow = 1. m/s Figure 5 The overall removal efficiency (825 µm particles) of the Flamcovent Clean for two different flow rates

12 Flamcovent Clean microbubble air separator with dirt chamber Flamcovent Clean. Types and specification Type Connection xternal pipe diameter (mm) Flamcovent Clean Flamcovent Clean 5S Flamcovent Clean 65S Flamcovent Clean S Flamcovent Clean S Flamcovent Clean 125S Flamcovent Clean 15S welded connections DN 5 DN 65 DN DN DN 125 DN Flamcovent Clean Flamcovent Clean 5F Flamcovent Clean 65F Flamcovent Clean F Flamcovent Clean F Flamcovent Clean 125F Flamcovent Clean 15F flanged connections DIN 26 (ND 16) DN 5 DN 65 DN DN DN 125 DN Dimensions llow at least mm for access Type Dimensions in mm ØD Content in litres Weight kg Flamcovent Clean welded connections /4" male ØD llow at least mm for access ØD Flamcovent Clean 5S Flamcovent Clean 65S Flamcovent Clean S Flamcovent Clean S Flamcovent Clean 125S Flamcovent Clean 15S Flamcovent Clean flanged connections DIN 26 (ND 16) Flamcovent Clean 5F Flamcovent Clean 65F Flamcovent Clean F Flamcovent Clean F Flamcovent Clean 125F Flamcovent Clean 15F Sizes 2 to are available to special order. /4" male Flamco UK Ltd reserve the right to alter specification and design without prior notice. Dimensions are in millimetres and are approximate.

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S. AIR AND DIRT SEPARATORS 7 Flamco FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN 2007 edition / UK FLAMCO A-S Flexvent : reliable and easy to mount The Flexvent 3 /8 and 1 /2 are supplied together

More information

Flamco. Flamco. Flamco. Venting range and dirt separators FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S

Flamco. Flamco. Flamco. Venting range and dirt separators FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S VENTING RNGE ND DIRT SEPRTORS Flamco Flamco Venting range and dirt separators FLEXVENT FLMCOVENT FLMCOVENT CLEN FLEXIR FLMCO CLEN Flamco Edition 2005 / EXP FLMCO -S Flamco Flexvent floatvents: reliable

More information

Venting Range and Air/Dirt Separators

Venting Range and Air/Dirt Separators . Venting Range and Air/Dirt Separators Systems in which the water is properly de-aerated and free of contamination are more efficient, produce less noise and have a longer service life. Our products use

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Proprietary Catalog Data Contact Local Spirotherm Representative for Technical Assistance

Proprietary Catalog Data Contact Local Spirotherm Representative for Technical Assistance Pressure Drop Chart System fluid passing through a Spirovent or Spirotrap will create a certain pressure drop, depending on the size of the nozzles, diameter of the shell, and the volume (flow) and speed

More information

FLEXCON EXPANSION VESSELS. Flamco FLEXCON 2-80. Flexcon. Expansion vessels FLEXCON 110 1000 FLEXCON M. Flamco FLEXCON V-B.

FLEXCON EXPANSION VESSELS. Flamco FLEXCON 2-80. Flexcon. Expansion vessels FLEXCON 110 1000 FLEXCON M. Flamco FLEXCON V-B. FLEXCON EXPANSION VESSELS Flamco 1 Flexcon Expansion vessels FLEXCON 2-80 FLEXCON 110 1000 FLEXCON M Flamco FLEXCON V- 2007 edition / UK Flamco Flexcon the first name in expansion vessels Flamco has over

More information

Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067

Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067 Flexcon M E Installation and operating instructions 2002 Flamco 1801067 Flamco b.v. P.O. Box 11 2800 AC Gouda - Holland Industriestraat 6 2802 AC Gouda - Holland Tel.: +31(0)182 91800 Fax: +31(0)182 227

More information

Expansion Vessels. 16 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

Expansion Vessels. 16 Product overview 2013 We reserve the right to change designs and technical specifications of our products. . Expansion Vessels Flamco produces a comprehensive range of diaphragm expansion vessels. Both the steel vessel and the diaphragm are of the highest quality. They are compliant with all prevailing European

More information

Automatic Minimum Flow System SMA 63 and SMA 64

Automatic Minimum Flow System SMA 63 and SMA 64 Figure 1 Automatic Minimum Flow System SMA 63 Advantage and Utility assurance of the required pump minimum continuous safe flow no inadmissible temperature increase in the pump; avoidance of cavitations

More information

Industrial automatic self-cleaning filters made in plastic material

Industrial automatic self-cleaning filters made in plastic material Industrial automatic self-cleaning filters made in plastic material FilBlue Introduction The FILBLUE automatic industrial selfcleaning filters are designed to remove all suspended solids from surface water

More information

VARIABLE VANE PUMPS V3

VARIABLE VANE PUMPS V3 VARIABLE VANE PUMPS V3 (series 30 and 40) Nominal sizes 12; 25; 40; 63 up to p n 100 bar V g 8.5; 19; 32; 47 cm 3 /rev KE 1015 11/02 replaces 07/97 easy commissioning due to automatic bleed facility low

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

APP pump instruction APP , APP and APP

APP pump instruction APP , APP and APP MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 0.6-1.0, APP 1.5-2.5 and APP 3.0-3.5 ro-solutions.com Table of Contents 1. Identification...3 2. System design...3 2.1 Open-ended systems

More information

Proprietary Catalog Data Contact Local Spirotherm Representative for Technical Assistance

Proprietary Catalog Data Contact Local Spirotherm Representative for Technical Assistance Particles in Hydronic Systems The life and efficiency of a heating or cooling system is greatly dependent on clean system water, because solid particles interfere with the proper operation of a hydronic

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Manual # OMAV2-SUMP1 High Performance Air & Dirt Separators Manual # 9636-1230 Rev. A Operation & Maintenance Manual 340 West 8 th Street Peru, IN 46970 PH: 765 472 3351 FX: 765 472 3968 www.thrushco.com

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

Pump-Transfer Cooler Filtration Unit UKF

Pump-Transfer Cooler Filtration Unit UKF Pump-Transfer Cooler Filtration Unit UKF Symbol General The UKF unit is a compact, easy-to-install system for offline filtration cooling circuits. It consists of a low-noise feed pump, a filter and a plate

More information

zeparo zi ZE Principles Range Benefits

zeparo zi ZE Principles Range Benefits zeparo zi ZE Principles Range Benefits Function The lifetime and efficiency of heating, solar and chilled water systems are strongly affected by the quality of the system water. Although the type and age

More information

Pumps and Filling Units for Solar Systems. for Heating Contractors

Pumps and Filling Units for Solar Systems. for Heating Contractors Pumps and Filling Units for Solar Systems Boiler - Solar Systems - Tanks Draining - Filling - Venting for Heating Contractors Solarcheck Mobilcenter for Solar Thermal Systems: Flushing, Filling in Heat

More information

Bladder Accumulators Standard

Bladder Accumulators Standard 1. Description 1.1. Function Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

Steam Boiler Working principle and Types of Boiler

Steam Boiler Working principle and Types of Boiler Steam Boiler Working principle and Types of Boiler Definition of Boiler Steam boiler or simply a boiler is basically a closed vessel into which water is heated until the water is converted into steam at

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

inplan Thermal Oil Boilers have been proven for many years by successful installation in more than 30 countries.

inplan Thermal Oil Boilers have been proven for many years by successful installation in more than 30 countries. established 1968 Thermal Oil Plants Top quality and sophisticated technology provide solutions for individual heating problems. inplan Thermal Oil Boiler alternatively of horizontal or vertical design

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.1 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm Features Very short control times Low noise Mounting

More information

SUBMERSIBLE PUMPS AFP 0831 to 2046

SUBMERSIBLE PUMPS AFP 0831 to 2046 SUBMERSIBLE PUMPS AFP 0831 to 2046 DIN/EN 12050-1 Robust, reliable sewage pumps from 1.3 to 22 kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and communal

More information

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN

More information

MEGAFLO SHRU Installation Instructions Shower Heat Recovery Unit

MEGAFLO SHRU Installation Instructions Shower Heat Recovery Unit MEGAFLO SHRU Installation Instructions Shower Heat Recovery Unit Energy saving performance recognised by SAP Leave these instructions with the user for the homes user pack Contents Page 2. Introduction

More information

Stainless Steel Calorifiers

Stainless Steel Calorifiers Energy efficient Hygienic Maintenance free Stainless Steel Calorifiers Technical Brochure High Quality 1.4521 Stainless Steel A Complete Range of Stainless Steel Calorifiers Flamco offers a wide selection

More information

Hotstore Stainless Steel Thermal Store Cylinder

Hotstore Stainless Steel Thermal Store Cylinder Hotstore Stainless Steel Thermal Store Cylinder Installation Guidance and Operating Instructions L318 General: These instructions must be read before undertaking installation or maintenance of Hotstore

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

Flamco Venting range and dirt separators

Flamco Venting range and dirt separators VNTING RNG ND DIRT SPRTORS Your reliable partner 7 Flamco FLXVNT FLMCOVNT FLMCOVNT CLN FLXIR FLMCO CLN N DITION exp 2009 The best ways of avoiding or solving problems One needs specialist knowledge to

More information

A Practical Guide to Free Energy Devices

A Practical Guide to Free Energy Devices A Practical Guide to Free Energy Devices Part PatC1: Last updated: 22nd October 2005 Author: Patrick J. Kelly Please note that this is a re-worded excerpt from this patent. If the content interests you,

More information

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUS1ON-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUS1ON-P TA-FUS1ON-P These innovative

More information

OIL SEPARATORS. 112

OIL SEPARATORS. 112 OIL SEPARATORS 111 OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

VENTILATION GUIDELINES FOR GAS/ELECTRIC REFRIGERATORS

VENTILATION GUIDELINES FOR GAS/ELECTRIC REFRIGERATORS VENTILATION GUIDELINES FOR GAS/ELECTRIC REFRIGERATORS Norcold, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Norcold Technical Support Telephone: 800-444-7210 Fax: 937-497-3183 Web Site: www.norcold.com Part

More information

APT10 and APT14. for effective condensate drainage and removal

APT10 and APT14. for effective condensate drainage and removal APT10 and APT14 for effective condensate drainage and removal 1 An innovative solution for effective heat APT14, APT14HC and APT14SHC Compact design which contains all the equipment needed to drain or

More information

Installation and Servicing Instructions

Installation and Servicing Instructions Installation and Servicing Instructions Alpha Plus Units for Domestic Hot water and Low Pressure or Direct For Technical help or for Service call... ALPHA HELPLINE Tel: 0844 8718764 website:www.alpha-innovation.co.uk

More information

AIRFIX EXPANSION VESSELS. Airfix. Expansion vessels for potable water systems AIRFIX A AIRFIX D AIRFIX D-E. 2007 edition / UK

AIRFIX EXPANSION VESSELS. Airfix. Expansion vessels for potable water systems AIRFIX A AIRFIX D AIRFIX D-E. 2007 edition / UK AIRFIX EXPANSION VESSELS 4 Airfix Expansion vessels for potable water systems AIRFIX A AIRFIX D AIRFIX D-E 2007 edition / UK Flamco offers you a wide choice of expansion vessels for potable water Airfix

More information

Process Screen Basket Filter PRFS

Process Screen Basket Filter PRFS Process Screen Basket Filter PRFS 130x 250x 520x 650x 1500x 2500x 1. Technical Specifications 1.1 General Screen basket filters are used mainly as coarse filters or prefilters. The direction of flow is

More information

KRF. Backflush Filter DN (ANSI 1 1 / 2 32") PN ISO 9001:2008. Applications. Brief description and operation. The cleaning effect

KRF. Backflush Filter DN (ANSI 1 1 / 2 32) PN ISO 9001:2008. Applications. Brief description and operation. The cleaning effect KRF Backflush Filter DN 32 800 (ANSI / 2 32") PN 6 40 Krone Filter Solutions GmbH Industriestr. 9 28876 Oyten / Germany Tel: +49 (0)4207 98 769-0 Fax: +49 (0)4207 98 769-27 filter@krone-filter.com www.krone-filter.com

More information

PRESSURIZATION AND AIR ELIMINATION SYSTEM TECHNICAL BULLETIN

PRESSURIZATION AND AIR ELIMINATION SYSTEM TECHNICAL BULLETIN PRESSURIZATION AND AIR ELIMINATION SYSTEM TECHNICAL BULLETIN The AMTROL pressurization and air elimination system accommodates the expanded water generated by the increase in temperature in a water heating

More information

Pressurized Expansion Tanks (ASME)

Pressurized Expansion Tanks (ASME) INSTRUCTION MANUAL A0500I WARNING LABEL PART NO. 905-46 INSTALLED IN THIS LOCATION. IF MISSING, IT MUST BE REPLACED. Series "B" Series "D" Series "B-LA" Pressurized Expansion Tanks (ASME) INSTALLER: PLEASE

More information

Mechanical Seal Piping Plans

Mechanical Seal Piping Plans Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,

More information

Vacuum Piping Guide Jets Standard

Vacuum Piping Guide Jets Standard Vacuum Piping Guide Jets Standard Sanitary Systems made to please Table of Contents 1 INTRODUCTION 1.1 Standards and regulations 1.2 Terms and Conditions 1.3 Safety Annotations 1.4 Support 2 SYSTEM DESCRIPTION

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A609/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

PRESSURE REDUCING VALVES

PRESSURE REDUCING VALVES 0E0-GB PRESSURE REDUCING VAVES MAIN FEATURES The pressure reducing valve is able, by varying its pressure drops, to hold the downstream pressure of the fluid at a constant level against changes in the

More information

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification

More information

SAMPLE. Supply main. Header. Boiler

SAMPLE. Supply main. Header. Boiler LESSON 5 direction for better separation of the condensate. The steam piping should come off the top of the header pipe to assure that only dry steam leaves the boiler. THE HARTFORD LOOP Areas A, B, and

More information

Calculation of Pressure Regulators

Calculation of Pressure Regulators Instruction Designing and selecting pressure regulating valves is not a secret science mastered only by a handful of experts. The procedure described below allows the user to select a suitable valve for

More information

Maintenance Information

Maintenance Information 876124 Edition B April 2013 Pneumatic Filters, Regulators, Lubricators, Filter/Regulators and Combination Units 849XXX Maintenance Information Save These Instructions Product Description The air line Filters,

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IOM-Heliflow-0507 HELIFLOW INSTALLATION, OPERATION AND MAINTENANCE MANUAL Graham Corporation Corporate and Sales Headquarters: 20 Florence Avenue, Batavia, New York 14020 USA Phone.: 585-343-2216 Fax:

More information

1c Ref: 02/98. Flexcon standard expansion vessels and sealed system equipment for commercial heating and air conditioning systems.

1c Ref: 02/98. Flexcon standard expansion vessels and sealed system equipment for commercial heating and air conditioning systems. 1c Ref: /9 lexcon standard expansion vessels and sealed system equipment for commercial heating and air conditioning systems Introduction Under the universally known and respected name of lexcon, have

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

2 µm. 0.5 to 2 µm

2 µm. 0.5 to 2 µm GAS FILTRATION OVERVIEW Twin Filter offers her relations coalescing, filtration and separation solutions to minimize operating costs. We manufacture a variety of filtration and separation products from

More information

ANNEX 10. Air pollution control system

ANNEX 10. Air pollution control system ANNEX 10 Air pollution control system Air pollution control system The air pollution will be the result of heating process in the reheat furnace. The flue gas will therefore require cleaning before discharge

More information

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz

01 GB. Refrigeration Dryer. High quality compressed air. F-Series. Energy efficient compressed air treatment. 50Hz & 60Hz 01 GB Refrigeration Dryer High quality compressed air Energy efficient compressed air treatment F-Series 50Hz & 60Hz Energy efficient refrigeration dryers First-class air treatment efficiency For CompAir,

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Relief Valve Type: KALB - S

Relief Valve Type: KALB - S Relief Valve Type: KALB - S 13 14 15 5 6 4 8 11 1 3 11 10 2 9 7 12 Red: input pressure Yellow: outlet pressure Green: cylinder space 1 Housing 2 Valve seat 3 Valve piston 4 Set point screw 5 Pilot cone

More information

SUBMERSIBLE PUMPS AFP 0831 to 2046

SUBMERSIBLE PUMPS AFP 0831 to 2046 SUBMERSIBLE UMS AF 0831 to 046 DIN/EN 1050-1 Robust, reliable sewage pumps from 1.3 to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and communal areas.

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

ELECTRIC BOILER INSTALLATION AND OPERATION MANUAL

ELECTRIC BOILER INSTALLATION AND OPERATION MANUAL ELECTRIC BOILER PW INSTALLATION AND OPERATION MANUAL JASPI UK www.northmangroup.co.uk Telephone: 01392 247340 Email: info@northmangroup.co.uk JÄSPI KNOWS HOW TO CREATE WARMTH AND COMFORT 1. Contents 1.

More information

SelfAct TM Selfacting Control Valve PN 10-40, DN

SelfAct TM Selfacting Control Valve PN 10-40, DN SelfAct TM Selfacting Control Valve PN -, DN - 0 SCHERR Application Self-actuating Pressure Reducing Valves are used to provide a constant pressure downstream of its built-in position. Suitable for steam,

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

GRUNDFOS DATA BOOKLET. Sololift2. Small lifting stations. 50 Hz

GRUNDFOS DATA BOOKLET. Sololift2. Small lifting stations. 50 Hz GRUNDFOS DATA BOOKLET Small lifting stations 0 Hz Table of contents. Product overview for toilet applications.................................................................... for grey wastewater applications...........................................................

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there

More information

Stratified tank PC. Combination tank (with corrugated stainless steel pipe) Thermosolar charging stratified stratified not stratified

Stratified tank PC. Combination tank (with corrugated stainless steel pipe) Thermosolar charging stratified stratified not stratified TANK TANK OVERVIEW Type designation Stratified tank PC Stratified tank PC 2WR Fresh water tank FS / 1R page 119 page 120 page 161 Type Combination tank (with corrugated stainless steel pipe) Thermosolar

More information

series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N

series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 235-11 Pressure Regulator Pressure build-up regulator Valve opens when the upstream pressure drops Pressure reducing valve Valve closes when

More information

CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER

CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER A steam boiler has been built and installed at a factory for the provision of process steam. The following lists the requirements used in the commissioning

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder INSTALLATION INSTRUCTIONS Wagner& Co ECOplus Solar Cylinder Connection Diagram Hot water consumer circulation pump Backflow preventer CORREX-UP impressed current anode Safety valve, 10 bar Hot water connection,

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPL4046 PVP are variable displacement axial piston pumps for high pressure operation,

More information

HERZ-TS-90. HERZ Armaturen. Standard sheet for 7723 /7724 / /7759 Edition 1000 (0999) Thermostatic Valve Lower Parts

HERZ-TS-90. HERZ Armaturen. Standard sheet for 7723 /7724 / /7759 Edition 1000 (0999) Thermostatic Valve Lower Parts Thermostatic Valve Lower Parts Standard sheet for /7724 /7728 7758 /7759 Edition 1000 (0999) 7724 7728 + 6249 7758 7759 Special Models 1 61 1 7737 91 1 7733 81 R = R 1/2" G = G 3/4 1 7724 58 1 7724 41

More information

Circular pumps BFP. Low noise emission. Built-in bell housing High vol. efficiency. Gerotor principle Good suction performance

Circular pumps BFP. Low noise emission. Built-in bell housing High vol. efficiency. Gerotor principle Good suction performance Circular pumps FP Low noise emission uilt-in bell housing High vol. efficiency Gerotor principle Good suction performance Not susceptible to contamination DE370001 12/2015 page 1 / 7 ühler Technologies

More information

Centrifugal pumps. Features of the centrifugal pump. Q/H curve

Centrifugal pumps. Features of the centrifugal pump. Q/H curve Features of the centrifugal pump Centrifugal pumps are fluid- kinetic machines designed for power increase within a rotating impeller. Therefore it is also called the hydrodynamic pumping principle. According

More information

2-way control valves VEFS 2

2-way control valves VEFS 2 Data sheet 2-way control valves VEFS 2 Description/Application VEFS 2 valves are a range of 2 port high specification flanged valves for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot

More information

High Static Pressure Ductable Fan Coil Unit Models 07 to 27

High Static Pressure Ductable Fan Coil Unit Models 07 to 27 VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 5.3 to 26.9kW 4.1 to 22.6kW 800 to 4650 m 3 /h VH 1 General Characteristics Presentation The new ducted high static pressure fan coil units

More information

APCO COMBINATION AIR VALVES

APCO COMBINATION AIR VALVES BULLETIN 3 JULY 014 APCO COMBINATION AIR VALVES Series 1800 Custom Combination Duplex Body Series 140C Standard Combination Single Body www.dezurik.com APCO Combination Air Valves Single Body Double Orifice

More information

HELICAL OIL SEPARATORS

HELICAL OIL SEPARATORS OIL SEPARATORS HELICAL OIL SEPARATORS The function of a Helical Oil Separator is to efficiently remove oil from the discharge gas and return it to the compressor, either directly or indirectly. This helps

More information

SMA SMA SMA. Automatic Minimum Flow System. 180 bar < Δp < 400 bar. look at info overview PN 250-PN 400 ANSI

SMA SMA SMA. Automatic Minimum Flow System. 180 bar < Δp < 400 bar. look at info overview PN 250-PN 400 ANSI 7 63 for non-speed controlled pumps 64 for speed controlled pumps Applications The 63/64 is a protection device for pump protection. It automatically protects centrifugal pumps from damages, which might

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on

More information

BALLOREX venturi 4.1 Introduction

BALLOREX venturi 4.1 Introduction BALLOREX venturi 4.1 Introduction 4.1.1 Balancing of heating and cooling systems BROEN BALLOREX Venturi is a range of manual balancing valves used in water-based heating and cooling systems to ensure an

More information

Queensland Road, Design 3137

Queensland Road, Design 3137 PANDORA HEAT BANKS Queensland Road, Design 3137 Installation Instructions THERMAL INTEGRATION LTD. Tel: 0845 2411441 Internet: www.heatweb.com General Requirements IMPORTANT General Requirements: 1. IN

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPH4046 PVP are variable displacement axial piston pumps for high pressure operation,

More information

Thermal safety drain valve Series STS.S

Thermal safety drain valve Series STS.S Thermal safety drain valve Series STS.S Main features - Double safety - 0 swivel connection of capillary - Available with different drain temperature settings: C, 8 C, 9 C, 9 C and 0 C - Installation in

More information

Pumping Technology OMEGA GLANDED PUMPS INSTALLATION AND OPERATION MANUAL

Pumping Technology OMEGA GLANDED PUMPS INSTALLATION AND OPERATION MANUAL OMEGA GLANDED PUMPS INSTALLATION AND OPERATION MANUAL IMPORTANT INFORMATION These instructions must be read and understood before installing, commissioning, operating or maintaining the equipment. This

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting

Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator

More information

SOLUTIONS GUIDE. For total efficiency

SOLUTIONS GUIDE. For total efficiency 2014-2015 SOLUTIONS GUIDE For total efficiency BALANCING VALVES Comap Ballorex is a complete range of static, dynamic and automatic valves for balancing hot and cold water circuits. Easily commissioned,

More information

DRY TYPE PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES.

DRY TYPE PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES. DRY TYPE PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES. SUITABLE FOR MEASUREMENT OF AIR PRESSURE, WATER PRESSURE, VACUUM PRESSURE, TOWN GAS, ETC. DIAMETER = 1",1.5",2",2.5",3",4",5",6"(25,40,50,60,75,100,125,150,)

More information

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None Low and High Static Pressure Fan Coil Units VH2N 03 to 27 Technical Brochure TM VH2N-A.1GB Date : June 2006 Supersedes : None Design Features Presentation The VH2N fan coil units has been specially designed

More information

Zenith Solar thermal 4.5m pump station Installation manual

Zenith Solar thermal 4.5m pump station Installation manual Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance

More information