1 WATER SOURCE / GEOTHERMAL HEAT PUMPS AND AIR CONDITIONERS Water Source / Geothermal Heat Pumps & Air Conditioners WHISPERLINE TM VERTICAL STACK u Classic Heat Pump / Air Conditioner u Single Riser Heat Pump / Air Conditioner WHISPERLINE TM DUCTED VERTICAL u Classic Heat Pump / Air Conditioner with Slide-out Chassis u Single Riser Heat Pump / Air Conditioner with Slide-out Chassis u Water-Source Heat Pump / Air Conditioner with Fixed Chassis WHISPERLINE TM HORIZONTAL u Heat Pump / Air Conditioner with Slide-out Chassis WHISPERPACK TM VERTICAL STACK u Air Conditioner with Hydronic Heating WHISPERPACK TM DUCTED VERTICAL u Air Conditioner with Hydronic Heating and Slide-out Chassis From the pioneer in vertical stack HVAC technology and innovation. P. O. Box 1390 Easton, MD USA Tel. (410)
2 Thank you for your interest in The Whalen Company. This catalog includes basic information on our comprehensive line of commercial air handlers and fan coil products. Additional data is available at where you can download the most current product specifications. You may also contact us at or KEY WSHP - Water Source Heat Pump GHP - Geothermal Heat Pump WSAC - Water Source Air Conditioner WLHP - PRODUCT DESCRIPTION WHISPERLINE TM SERIES Classic WSHP/GHP/WSAC applications Vertical stack with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm Single Riser System with integral pump WSHP/GHP/WSAC applications Vertical stack with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm Ducted Vertical Products Classic WSHP/GHP/WSAC applications Ducted vertical with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm Single Riser System with integral pump WSHP/GHP/WSAC applications Ducted vertical with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm WWSVX Water Source Heat Pump WLHP applications Ducted vertical with fixed chassis 1 ½ to 5 Tons Horizontal Products WWSHX Water Source Heat Pump WLHP applications Ducted horizontal unit ¾ to 5 Tons WHISPERPACK TM SERIES Vertical Stack Products Whisperpack TM Water Source AC with Hydronic Heating WSHP/WSAC applications Vertical Stack with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm Ducted Vertical Products Whisperpack TM Water Source AC with Hydronic Heating WSHP/WSAC applications Ducted vertical with slide-out chassis ½ to 3 Tons 200 to 1200 Cfm PAGE
3 Whisperline TM Vertical Stack Classic Water Source/Geothermal Heat Pump and Air Conditioner A proven time and money saving concept in air conditioning any type of building... advantageous for both new construction and the renovation of apartments, condominiums, hotels, senior living facilities, dormitories and office buildings. Flexible configuration Efficient operation Low installed cost Reduced maintenance costs Small footprint Clean and quiet operation Vertical Stack Whisperline TM Classic Model Applications Risers Tons VI-A-203 S ½ VI-A-303 S A - Water Source and Geothermal Heat Pump ¾ VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) Standard 1 VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) Master 1 ¼ VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat Slave 1 ½ VI-A-803 D D - Water Source Air Conditioning Unit Special 2 VI-A-1003 D 2 ½ VI-A-1203 D 3 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Ground Loop Heat Pump Cooling 86 F Heating 68 F Cooling 77 F Heating 32 F EER / W COP EER / W COP VI-A-203 S , , , , VI-A-303 S , , , , VI-A-403 S , , , , VI-A-503 D , , , , VI-A-603 S , , , , VI-A-803 D , , , , VI-A-1003 D , , , , VI-A-1203 D , , , , Cooling based upon 80.6 F DB, 66.2 F WB entering air temperature Heating based upon 68 F DB, 59 F WB entering air temperature Model Compressor R-410A Refrigerant Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) VI-A-203 S Rotary 23.5 PSC, EC 145 / 85 VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary PSC, EC 145 / 89 VI-A-503 D Rotary 33.5 PSC, EC /60/1 165 / 128 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-803 D Rotary 38 EC 165 / 138 VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 /
4 Whisperline TM Vertical Stack Single Riser System with Integral Pump Water Source/Geothermal Heat Pump and Air Conditioner By using only one riser to distribute fluid to a heat pump when two pipes are usually required, allows designers to specify a single riser size to help control costs during initial and payout phases of construction. Superior comfort Efficient, clean and quiet operation Robust, energy-saving green design Small footprint... flexible configurations Reduced project design requirements Lower installation cost... lower O&M costs Vertical Stack Whisperline Single TM Riser Single System Riser (SRS) System with Integral (SRS) Pump with Integral Pump Model Applications Risers Tons VI-A-203 S ½ VI-A-303 S A - Water Source and Geothermal Heat Pump ¾ VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) Standard 1 VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) Master 1 ¼ VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat Slave 1 ½ VI-A-803 D D - Water Source Air Conditioning Unit Special 2 VI-A-1003 D 2 ½ VI-A-1203 D 3 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Ground Loop Heat Pump Cooling 86 F Heating 68 F Cooling 77 F Heating 32 F EER / W COP EER / W COP VI-A-203 S , , , , VI-A-303 S , , , , VI-A-403 S , , , , VI-A-503 D , , , , VI-A-603 S , , , , VI-A-803 D , , , , VI-A-1003 D , , , , VI-A-1203 D , , , , Cooling based upon 80.6 F DB, 66.2 F WB entering air temperature Heating based upon 68 F DB, 59 F WB entering air temperature Model Compressor R-410A Refrigerant Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) VI-A-203 S Rotary 23.5 PSC, EC 145 / 85 VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary PSC, EC 145 / 89 VI-A-503 D Rotary 33.5 PSC, EC /60/1 165 / 128 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-803 D Rotary 38 EC 165 / 138 VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 /
5 Whisperline TM Ducted Vertical with Slide-out Chassis Classic Water Source/Geothermal Heat Pump and Air Conditioner A vertical unit requiring access on only one side and serviceability that provides added flexibility over traditional units. Used in a variety of new and renovation construction projects similar to apartments, dormitories and office buildings. Only one side access required with slide-out chassis. Flexible configurations Efficient operation Reduced maintenance costs Small footprint Clean and quiet operation Whisperline Closetline CLASSIC TM Ducted Classic Model Applications Risers Tons VI-A-203 S ½ VI-A-303 S A - Water Source and Geothermal Heat Pump ¾ VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) Standard 1 VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) Master 1 ¼ VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat Slave 1 ½ VI-A-803 D D - Water Source Air Conditioning Unit Special 2 VI-A-1003 D 2 ½ VI-A-1203 D 3 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Ground Loop Heat Pump Cooling 86 F Heating 68 F Cooling 77 F Heating 32 F EER / W COP EER / W COP VI-A-203 S , , , , VI-A-303 S , , , , VI-A-403 S , , , , VI-A-503 D , , , , VI-A-603 S , , , , VI-A-803 D , , , , VI-A-1003 D , , , , VI-A-1203 D , , , , Cooling based upon 80.6 F DB, 66.2 F WB entering air temperature Heating based upon 68 F DB, 59 F WB entering air temperature Model Compressor R-410A Refrigerant Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) VI-A-203 S Rotary 23.5 PSC, EC 145 / 85 VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary PSC, EC 145 / 89 VI-A-503 D Rotary 33.5 PSC, EC /60/1 165 / 128 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-803 D Rotary 38 EC 165 / 138 VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 /
6 Whisperline TM Ducted Vertical with Slide-out Chassis Single Riser System with Integral Pump Water Source/Geothermal Heat Pump and Air Conditioner By using only one riser to distribute fluid to a heat pump when two pipes are usually required, this unit allows designers to specify a single riser size to help control costs during initial and payout phases of construction. Only one side access required with slide-out chassis. Efficient, clean and quiet operation Robust, energy-saving green design Small footprint... flexible configurations Reduced project design requirements Lower installation cost... lower O&M costs Whisperline TM Ducted Single Riser System (SRS) with Integral Pump Closetline Single Riser System (SRS) with Integral Pump Model Applications Risers Tons VI-A-203 S ½ VI-A-303 S A - Water Source and Geothermal Heat Pump ¾ VI-A-403 S A1 - Water Source Heat Pump with Electric Heat (Boilerless Design) Standard 1 VI-A-503 D A2 - Water Source/Geothermal Heat Pump with Electric Heat (Supplemental) Master 1 ¼ VI-A-603 S B - Water Source Air Conditioning Unit with Electric Heat Slave 1 ½ VI-A-803 D D - Water Source Air Conditioning Unit Special 2 VI-A-1003 D 2 ½ VI-A-1203 D 3 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Ground Loop Heat Pump Cooling 86 F Heating 68 F Cooling 77 F Heating 32 F EER / W COP EER / W COP VI-A-203 S , , , , VI-A-303 S , , , , VI-A-403 S , , , , VI-A-503 D , , , , VI-A-603 S , , , , VI-A-803 D , , , , VI-A-1003 D , , , , VI-A-1203 D , , , , Cooling based upon 80.6 F DB, 66.2 F WB entering air temperature Heating based upon 68 F DB, 59 F WB entering air temperature Model Compressor R-410A Refrigerant Charge (oz.) Fan Motor Voltage Estimated Ship Weight Cabinet / Chassis (lbs) VI-A-203 S Rotary 23.5 PSC, EC 145 / 85 VI-A-303 S Rotary 26 PSC, EC 145 / 87 VI-A-403 S Rotary PSC, EC 145 / 89 VI-A-503 D Rotary 33.5 PSC, EC /60/1 165 / 128 VI-A-603 S Rotary 35 PSC, EC 265/60/1 165 / 129 VI-A-803 D Rotary 38 EC 165 / 138 VI-A-1003 D Scroll 48.5 EC 185 / 171 VI-A-1203 D Scroll 54 EC 185 /
7 Whisperline TM Ducted Vertical with Fixed Chassis WWSVC/WWSVX Water Source Heat Pump and A/C 1-1/2 thru 5 Tons 100% Factory run tested. All units operate with environmentally friendly R-410 refrigerant. Heavy Gauge Galvanized Steel Cabinet. Cabinets insulated with ¾ Tuf-Skin RX treated with an anti-microbial agent. Non-corrosive Thermoplastic Condensate Pan, sloped for positive drainage. High and Low pressure Service Ports. Refrigerant Filter-drier and Discharge Muffler. Coaxial water-to-refrigerant heat exchanger. Heat exchanger available in Copper or CuproNickel. Digital Control Module (DCM). Available with energy saving ECM motor Reversable Blower. Multi-speed blower motor. Panel-mounted FPT Water Connections. High efficiency rotary or scroll compressor. System reversing valve (4-way). Large Removable Panels for Service access. 50 VA Transformer. 1 Throwaway Filter. 208/230/1PH ASHRAE/ANSI/AHRI/ISO Standard Cooling 86 F Heating 68 F EER / W WWSVC , , WWSVC , , WWSVC , , WWSVC , , WWSVC , , WWSVC , , WWSVC , , WWSVC , , WWSVC , , COP ASHRAE/ANSI/AHRI/ISO Standard Cooling 86 F Heating 68 F EER / W COP WWSVX , , WWSVX , , WWSVX , , WWSVX , , WWSVX , , WWSVX , , WWSVX , , Model Width Depth Height WWSVC WWSVC WWSVC WWSVC WWSVC WWSVC WWSVC WWSVC WWSVC
8 Whisperline TM Horizontal WWSHC/WWSHX Horizontal Water Source Heat Pump and A/C 3/4 thru 5 Tons 100% Factory run tested. All units operate with environmentally friendly R-410 refrigerant. Heavy Gauge Galvanized Steel Cabinet. Cabinets insulated with ¾ Tuf-Skin RX treated with an anti-microbial agent. Non-corrosive Thermoplastic Condensate Pan, sloped for positive drainage. High and Low pressure Service Ports. Refrigerant Filter-drier and Discharge Muffler. Coaxial water-to-refrigerant heat exchanger. Heat exchanger available in Copper or CuproNickel. Digital Control Module (DCM). EER / W WWSHC , , WWSHC , , WWSHC , , WWSHC , , WWSHC , , WWSHC , , WWSHC , , WWSHC , , WWSHC , , ASHRAE/ANSI/AHRI/ISO Standard Cooling 86 F Heating 68 F EER / W WWSHX , , WWSHX , , WWSHX , , WWSHX , , WWSHX , , WWSHX , , WWSHX , , Available with energy saving ECM motor COP ASHRAE/ANSI/AHRI/ISO Standard Cooling 86 F Heating 68 F COP Multi-speed blower motor. Panel-mounted FPT Water Connections. High efficiency rotary or scroll compressor. System reversing valve (4-way). Large Removable Panels for Service access. 50 VA Transformer. 1 Throwaway Filter. 208/230/1PH Other voltages available contact factory. Model Length Width Height WWSHC WWSHC WWSHC WWSHC WWSHC WWSHC WWSHC WWSHC WWSHC
9 Whisperpack TM Vertical Stack Air Conditioning with Hydronic Heating Water Source Air Conditioning with Water Heating By packaging the best characteristics of our compressorized and fan coil product lines, we have developed a unit that offers the air conditioning performance we are known for with the operational characteristics found in our proven fan coil units. Flexible configurations Package design lowers field labor cost Incorporates energy sharing concepts Easy maintenance Clean and quiet operation Vertical Stack Whisperpack Air TM Air Conditioning with Hydronic with Hydronic Heating Heating Model Applications Risers Tons VP-C-203 D ½ VP-C-303 D ¾ VP-C-403 D Standard 1 VP-C-503 D C - Air Conditioning Master 1 ¼ VP-C-603 D with Hydronic Heating Slave 1 ½ VP-C-803 D Special 2 VP-C-1003 D 2 ½ VP-C-1203 D 3 AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Model Cooling 86 F CFM GPM Heating based upon 2 row coil, 70 F DB entering air temperature, 105 F entering li R-410A Refrigerant Model Compressor Voltage Charge (oz.) Fan Motor -9- EER / W Heating GPM Estimated Ship Weight Cabinet / Chassis (lbs) VP-C-203 D Rotary 23 PSC, EC 153 / 88 VP-C-303 D Rotary 24 PSC, EC 153 / 90 VP-C-403 D Rotary 26.3 PSC, EC 153 / 93 VP-C-503 D Rotary /60/1 34 PSC, EC 173 / 135 VP-C-603 D Rotary 265/60/1 34 PSC, EC 173 / 136 VP-C-803 D Rotary 36 EC 173 / 148 VP-C-1003 D Scroll 46 EC 192 / 183 VP-C-1203 D Scroll 51 EC 192 / 194 Entering Liquid Temp Heating 105 F EER / W VP-C-203 D VP-C-303 D VP-C-403 D VP-C-503 D VP-C-603 D VP-C-803 D VP-C-1003 D VP-C-1203 D Cooling based upon 80.6 F DB, 66.2 F WB entering air temperature, 86.0 F entering liquid temperature. Heating based upon 2 row coil, 70 F DB entering air temperature, 105 F entering liquid temperature.
10 Whisperpack TM Ducted Vertical with Slide-out Chassis Air Conditioning with Hydronic Heating Water Source Air Conditioning with Water Heating By packaging the best characteristics of our compressorized and fan coil product lines, we have developed a unit that offers the air conditioning performance we are known for with the operational characteristics found in our proven fan coil units. Only one side access required with slide-out chassis. Package design lowers field labor cost Incorporates energy sharing concepts Easy maintenance Clean and quiet operation Whisperpack TM Ducted Air Conditioning with Hydronic Heating Model Applications Risers Tons VP-C-203 D ½ VP-C-303 D ¾ VP-C-403 D Standard 1 VP-C-503 D C - Air Conditioning Master 1 ¼ VP-C-603 D with Hydronic Heating Slave 1 ½ VP-C-803 D Special 2 VP-C-1003 D 2 ½ VP-C-1203 D 3 Model AHRI Certified - ASHRAE/ANSI/AHRI/ISO Standard Entering Liquid Temp Heating Heating 105 F Cooling 86 F CFM GPM GPM EER / W EER / W VP-C-203 D VP-C-303 D VP-C-403 D VP-C-503 D VP-C-603 D VP-C-803 D VP-C-1003 D VP-C-1203 D Cooling based upon 80.6 F DB, 66.2 F WB entering air temperature, 86.0 F entering liquid temperature. Heating based upon 2 row coil, 70 F DB entering air temperature, 105 F entering liquid temperature. Model Compressor Voltage R-410A Refrigerant Charge (oz.) Fan Motor -10- Estimated Ship Weight Cabinet / Chassis (lbs) VP-C-203 D Rotary 23 PSC, EC 153 / 88 VP-C-303 D Rotary 24 PSC, EC 153 / 90 VP-C-403 D Rotary 26.3 PSC, EC 153 / 93 VP-C-503 D Rotary /60/1 34 PSC, EC 173 / 135 VP-C-603 D Rotary 265/60/1 34 PSC, EC 173 / 136 VP-C-803 D Rotary 36 EC 173 / 148 VP-C-1003 D Scroll 46 EC 192 / 183 VP-C-1203 D Scroll 51 EC 192 / 194
11 Notes:
12 Take the Next Step To learn more about how The Whalen Company can help you save time and money on your next project, contact your local Whalen representative, call to speak with one of our specialists, or your request to Additional technical resources, including dimensional drawings and Revit models, are available on our website at or at Behind every unit that carries the Whalen name is a singularity of purpose: the engineering and manufacturing of products that improve the quality of life for our customers. Our long-term commitment to this endeavor assures you of systems that are distinctive in concept, performance, reliability and value. The number of industry firsts from Whalen is impressive. They include: The industry s first vertical stack valveless fan coils The first vertical stack heat pump offering The first removable chassis closet-type heat pumps The first AHRI-listed water-cooled air conditioning units with hydronic heat Your Whalen Representative: Let us put Whalen innovation to work for you, too. Find out how our approach to your project will deliver a perfect fit solution and make your life easier. P.O. Box 1390 Easton, MD USA Tel Fax: Closetline, Closetpack, Whisperline and Whisperpack are trademarks of The Whalen Company The Whalen Company. All rights reserved. CAS-WA-WL-ALL-rev. 0615
CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:
CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living
catalog Single Package Vertical Air Conditioners and Heat Pumps
catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................
Geothermal Comfort Systems
Geothermal Comfort Systems The Bryant Geothermal Advantage Throughout Bryant's historic 100-year legacy, the company has provided millions of homeowners with the finest comfort systems available. Offering
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
Installation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
Single Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
Local Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
Nordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
Mechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Greensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
Think Green Think Renewable Think
TM Think Green Think Renewable Think BoschGeo.com 1 Greensource Residential Geothermal Heat Pumps CDi Series: SM Model Split Orientation BoschGeo.com 1 Residential Geothermal Heat Pumps About the Bosch
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
Split System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
TWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT
48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED
Split System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
How To Use A Water Source Heat Pump
Geothermal Energy Using Water-Source Heat Pumps By VIRSTAR Corporation Geothermal Expertise Since 1978 All information contained herein is the exclusive property of VIRSTAR Corporation, all rights reserved.
Split System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged
INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com
Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently
Cased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only
Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. BUILT FOR COMFORT. BUILT FOR YOU. ForeFront Series Air Handlers Our most innovative offering is also our most efficient.
Residential Air Conditioning. Program Standards
Residential Air Conditioning Program Standards Effective: January 1, 2015 Florida Power & Light Company Residential Air Conditioning Program Standards Table of Contents Program Objective... 1 Customer
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is
1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%
1 1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 2. How much money do commercial facilities spend per square foot on energy costs
How To Design A Building In New Delhi
ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce
U.S. General Services Administration Federal Supply Service
U.S. General Services Administration Federal Supply Service Authorized Federal Supply Schedule Price List Schedule 084 Total Solutions for Law Enforcement, Security, Facilities Management, Fire, Rescue,
ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT
ZUBA-CENTRALTM Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT Energy-efficient. Easy to install. Extremely quiet. Zuba-Central is simply the new and better
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Cooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded
It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
Defining Quality. Building Comfort. Heating and Cooling Coils
Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.
INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
Ductless Heat Pumps. Gary Nordeen January 2009. www.nwbuildings.org/dhp.aspx [email protected]
Ductless Heat Pumps Gary Nordeen January 2009 www.nwbuildings.org/dhp.aspx [email protected] Outline Heat Pump Basics Ductless Heat Pumps Efficiency Advantages Commercial installations Planning (applications,
GEOTHERMAL HEATING AND COOLING INTRODUCTION
GEOTHERMAL HEATING AND COOLING INTRODUCTION Geothermal Heating and Cooling Systems provide space conditioning -- heating, cooling, and humidity control. They may also provide water heating -- either to
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
Catalog 1320-2 McQuay Type EA Incremental Air Conditioner and Heat Pump
Catalog 1320-2 McQuay Type EA Incremental Air Conditioner and Heat Pump Model PMEG, PMES, PMRS Table of Contents MNN Product Description... 2 Product Nomenclature... 2 Introduction... 3 Type EA Applications...
SPECIFICATION CATALOG. Commercial 1.5 to 6 Ton. Geothermal/Water Source Heat Pump
SPECIFICATION CATALOG Commercial 1.5 to 6 Ton Geothermal/Water Source Heat Pump Table of Contents Model Nomenclature.... 4 AHRI Data...5-6 The Versatec Base Series... 7-11 Inside the Versatec Base Series....12-14
Customized Assessment Blueprint
Customized Assessment Blueprint HVAC Installer Basic - Test Codes: 7906 and 7796 Measuring What Matters Competencies and Skills Tested in this Assessment: HVAC Theory Heat Theory and Refrigeration HVAC
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Selection Tips For Air-Conditioning Cooling Systems
PDHonline Course M117 (2 PDH) Selection Tips For -Conditioning Cooling Systems Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
PTAC Selection Guide. Optimize your spend with the right PTAC equipment!
PTAC Selection Guide Optimize your spend with the right PTAC equipment! The Direct Supply Difference Direct Supply Equipment & Furnishings understands the challenges of securing equipment for your communities.
Tim Sisson - Trane HVAC OVERVIEW
Tim Sisson - Trane HVAC OVERVIEW HVAC Systems System Types Acoustics Controls Modernization more than one Down to the Studs Opportunity for new System Type Renovation Possible opportunity for new System
Heating, Ventilation & Air Conditioning Equipment
FinAnswer Express Wyoming Incentive Catalog Effective as of October 1, 2011 Heating, Ventilation & Air Conditioning Equipment Rocky Mountain Power provides incentives for many types of energy efficient
EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY
EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY Spectrum Manufacturing warrants that the heat pumps and air handling equipment (if purchased with a Water to Water System) manufactured by Spectrum Manufacturing
SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.
SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
Introduction To VRF: System Overview, Applications, & Savings Opportunities
Introduction To VRF: System Overview, Applications, & Savings Opportunities System Overview What is VRF? Zoning System Two-Pipe / Three Pipe System Packaged DDC Control Operates as a Heat Pump Simultaneous
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
Performance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
Split System Cooling Product Data
Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy
Introduction. Motor Types
QwikSEER+ Theory of Operation and Retrofit Potential Mainstream Engineering Corporation Rockledge, FL 32955 http://www.qwik.com/products/qwikseer/index.jsp Prepared by Robert P. Scaringe and R. Paul Roth
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
EnergyPro Building Energy Analysis. Assisted Living Building
EnergyPro Building Energy Analysis Assisted Living Building EnergyPro Building Energy Analysis for an assisted living building Project Scope The purpose of the EnergyPro energy model was to evaluate the
RHF High Efficiency Remote Heat Pumps and Matching Blower Coils
Heating&Air Conditioning RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Amana RHF heat pumps and matching blower coils offer economy, superior heating and cooling comfort, plus installation
Heating, Ventilation & Air Conditioning Equipment
FinAnswer Express Utah Incentive Catalog Effective as of May 19, 2012 Heating, Ventilation & Air Conditioning Equipment Rocky Mountain Power provides incentives for many types of energy-efficient technologies.
Cool Design for Homes and Offices
AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners
DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED
Engineering Specifications
Engineering Specifications NORDIC W-85-H-B-*S-PD Water to Water Heat Pump Single-Stage R134a Nominal 7.5 Ton With Double Wall Condenser for Domestic Hot Water Production Maritime Geothermal Ltd. P.O. Box
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
RUUD AIR CONDITIONERS & HEAT PUMPS
A Design So Smart It's Simple. RUUD AIR CONDITIONERS & HEAT PUMPS We Thought of Everything... And Then Some. We talked to a lot of dealers before we re-engineered our air conditioner and heat pump line.
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
www.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
Heating & Cooling Efficiency
Heating & Cooling Efficiency Advantages of Geothermal HVAC Efficiency Keith Swilley Gulf Power Company Why Gulf Power Promotes Energy Efficiency? Customer Satisfaction Education Help Customers Make Smart
LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Product Data. Features/Benefits. AquaForce 30XA080-501 Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)
Product Data AquaForce 080-501 Air-Cooled Liquid Chillers 80 to 500 Nominal Tons (265 to 1740 Nominal kw) a30-4024 Well exceeds ASHRAE 90.1 Standards. AquaForce chillers were designed from the ground up
Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency
FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
SPLIT SYSTEMS A PRIMER. By: Thomas Legutko and Michael Taylor Carrier Corporation Syracuse, New York
SPLIT SYSTEMS A PRIMER By: Thomas Legutko and Michael Taylor Carrier Corporation Syracuse, New York September 2000 TABLE OF CONTENTS INTRODUCTION...2 SPLIT SYSTEM BASICS...3 Evaporator...3 Compressor...4
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Product Data. Split System Cooling 22-1904-1F-EN. March 2015
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:
APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application
APPLICATION GUIDE Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application Section Comparison of Latent Cooling Performance of Introduction Most commercial HVAC systems
HA HE Series. Solutions for Your needs. fl exible and confi gure-to-order coils. Healthy Solutions coils
Series air handlers evaporator coils HA HE Series Healthy Solutions coils unit heaters fl exible and confi gure-to-order coils Solutions for Your needs our features. your benefits. Easy Installation and