1 Specifications and Ordering Information System 1 Optimization and Diagnostics Software Patents: 5,905,989; 6,421,571 Description System 1 Software is a patented, modular machinery management platform for process and equipment optimization, condition monitoring and event diagnostics. The client/server-based architecture is both scalable and flexible. This allows you to focus on your most critical needs and then continue to grow your system by adding new application packages and system extenders. System 1 software integrates all of this into a single system, with a single display environment and common database structure. The System 1 platform enables operators, equipment engineers, process engineers, instrument technicians, and other plant personnel to quickly identify, evaluate, and respond to important events to optimize the business impact. This increases equipment availability and reliability, and reduces maintenance costs. A growing suite of specially-designed application packages exists to meet the needs of individual plant equipment and users. These packages supplement System 1 Platform and support high-resolution data acquisition, trending, alarming, exception reporting, and user notification. The highly modular architecture of the System 1 software facilitates the expansion of data acquisition capabilities and the addition of machinery/asset management tools. These tools include data collection modules (DCMs) for collecting data from the Snapshot for Windows CE portable data collector, TDXnet and TDI communications processors, 1701 FieldMonitor, NetDDE, OPC, and the Dynamic Scanning Module for the Trendmaster Pro system. You can also collect Modbus data using the new System 1 Modbus software. Future modules will provide machinery management tools such as machine balancing software and provide additional condition monitoring technologies such as oil analysis, thermography, emissions and corrosion. System 1 software also provides a suite of System Extender applications to complement and expand the capability of the system. These include options for CMMS Interfaces (SAP PM and MRO Maximo), Data Exporters (OPC, DDE, and OLE Automation), Event Relay Card Software, and The Bearing Expert. In addition, the new Decision Support Studio with Rule Logic Results allows users to embed their domain knowledge into the system. This permits the system to evaluate real-time data, generate sophisticated alerts and alarms, and produce intelligent advisories that deliver Actionable Information to select users. The System 1 platform employs Microsoft Server technology to provide data acquisition and Decision Support functionality. It also uses a specialized Microsoft SQL database design for fast data storage, event capture and history, equipment properties and configuration information. The system provides a variety of industry standard interfaces to integrate with control and automation applications. System 1 software has been developed specifically for the Microsoft Windows XP/2000 operating systems, offering users a familiar interface and significant installed base of these industry standard operating systems. FOR REFERENCE ONLY Specifications and Ordering Information Page 1 of 10

2 Table 1 The System 1 Application Packages Application Name Turbo Machinery Integral Gear Hydro Turbine / Generator Electrical Equipment Wind Turbine Fired Equipment Reciprocating Machine Performance Portable Data Function Advanced on-line condition monitoring and diagnostic software package for critical rotating machinery applications. Features interfaces to Bently Nevada Protection Systems and sophisticated vibration diagnostics capabilities. Advanced on-line condition monitoring and diagnostic software package for integral gear compressors. Advanced on-line machine condition monitoring and diagnostic software package for hydro turbines and generators. Includes specialized diagnostics tools and measurement support. Advanced on-line electrical equipment condition monitoring and diagnostic software package for motors, generators, and transformers. This package interfaces to electrical protection devices such as GE Multilin s. Advanced on-line machine condition monitoring and diagnostic software package for wind turbines. Real-time condition monitoring and diagnostics for fired equipment such as boilers and furnaces. This package helps reduce emissions, improve heat rate, minimize slagging/fouling, and diagnose burner, boiler, and process heater problems. Advanced on-line mechanical and performance condition monitoring and diagnostic software package for critical reciprocating machinery applications. Includes sophisticated Pressure-Volume analysis capabilities. Robust asset-focused thermodynamic performance condition monitoring and diagnostics application. Optional pre-engineered calculation templates (Bently PERFORMANCE ) are available for machines such as gas turbines, compressors, pumps, steam turbines, and generators. Portable walk-around application supporting the Snapshot family of portable data collectors. This Trendmaster Pro Data Historian includes a two-channel, onechannel IS, and PDA portables for operator rounds. Bently Nevada s Trendmaster Pro online scanning system intended for managing essential and balance-of-plant machinery. Full-featured asset data historian interfaces to data systems for importing static/tag data. Leverages industry standard protocols (e.g. OPC, DDE, Modbus as well as custom interfaces to collect, alarm, store, and generate events for high resolution tag data. Ideal for monitoring, diagnostics, and optimization. Table 2 The System 1 System Extender Applications Application Name Decision Support Studio RuleDesk Pro Rule Logic Results CMMS Interfaces (Maximo and SAP) Function A powerful tool for experts to embed domain knowledge of equipment and processes into the real-time data system. Uses intuitive graphical tools to write and edit rules comprised of equations / algorithms. Rules may be written to optimize plant operation, give early detection of mechanical, operational, or instrument events, or derive parametric variables for trending and alarming. Decision Support Studio includes essential rule testing, documentation, and a robust security model to protect business sensitive knowledge. Decision Support rules use inputs and generate outputs (events, calculations, etc.). In order for rules to be processed, Rule Logic Results must be available in the system. This provides scalable real-time rule processing. Provides an interface to select Computerized Maintenance Management Systems. Data Exporters Export real-time from System 1 to the DCS, Historians, etc. Includes OPC DA, DDE, OLE Automation. Event Relay Card and Software The Event Relay Notification component can trip a relay in response to an event of a specified type, severity and FOR REFERENCE ONLY Specifications and Ordering Information Page 2 of 10

3 DSM Modbus Exporter The Bearing Expert asset location. Works with the Decision Support Application. Export static data from Trendmaster DSMs using Modbus. Enhances configuration of machines with rolling element bearing by providing a bearing database. Identifies key parameters based on Manufacturer, model or dimension of the bearing. contact your local Bently Nevada Sales and Service representative. For limited online, portable, or Display/Configuration installations, the following requirements are the recommended minimum for the System 1 software to operate. If these requirements are not met, the performance of the application may not be acceptable, and in some cases the software will not run properly. We strongly recommend that you contact your local Bently Nevada Sales and Service representative for a list of tested and approved workstations. Table 3 The System 1 Basic Modules Module Name Data Acquisition Display and Configuration Database (SQL Server) Web Server Function Communicates and acquires data from many sources. Displays all data on any connected data acquisition or database station. Configures the system hardware and software. Stores all historical machinery data, asset information, system hardware, and enterprise configuration. Provides internet or intranet connection to a System 1 enterprise. (requires MS Internet Information Server [IIS]) The System 1 client/server architecture allows you to locate Display (client) stations anywhere within your plant s Local Area Network (LAN), Wide Area Network (WAN), or Remote Access Server providing the ability to display and share data with one or more data acquisition (server) stations. System 1 software can share data with plant control and automation systems using either OPC, DDE, or OLE Automation protocols. Trendmaster Pro DSM can export to control and automation systems using Modbus. A network interface is supported using data exporters that provide formatted output of all static variables and status data. System 1 software supports time-synchronization between with other systems (e.g. process control or machine control systems) using appropriate computer peripherals and software available from Bently Nevada. System Specifications Computer Minimum Requirements: For demanding online DAQ (Data Acquisition) installations, we strongly recommend that you use an approved and tested server grade computer. For a list of approved servers, please 800 MHz Pentium III Processor 256 MB RAM 9 GB Hard Disk Drive 3.5 Floppy Disk Drive 24X CD-ROM Drive 8 MB Video Card Operating System Data Acquisition; Database (MS SQL Server 2000 ) Software: MS Windows 2000 Server Service Pack 4 MS Windows Server 2003 Notes: System 1 Data Acquisition is not supported by MS Windows NT. Display ; Configuration; Data Acquisition (Small Snapshot Only) Software: MS Windows 2000 Professional Service Pack 3 MS Windows XP MS Windows 2000 Server Service Pack 4 MS Windows Server 2003 Note: System 1 Client Software does not support MS Windows NT. Data Acquisition /SQL Server Station: Number of simultaneous Display/Configuration clients MS Windows Server 2003 Virtually unlimited simultaneous clients MS Windows 2000 Server Virtually unlimited simultaneous clients MS Windows 2000 Professional / MS Windows XP 10 simultaneous clients Note: When ordered from Bently Nevada, server operating systems come with 5 Client Access Licenses (CALs). FOR REFERENCE ONLY Specifications and Ordering Information Page 3 of 10

4 Supported Hardware Systems may support the following hardware depending on the ordered Application Packages. System limitations are listed below. Supported Monitor Systems and Communication Processor Types: 3500, 3300, 2201, 1701 TDI, TDXnet, TDIXconnX, TDe devices per data acquisition Unlimited of configurable machine trains: Unlimited of configurable portable points per data acquisition 20,000 portable points Supported Portable/Scanning Types: Trendmaster Pro DSM Snapshot Portable Portable IS Snapshot Clipboard via PDA Note: See Snapshot Clipboard data sheet, part number , for additional devices. of Communications Processors (CP)/ Equivalent FieldMonitor units per data acquisition 12 of TrendMaster Pro DSMs per data acquisition 150 of Modbus devices per data acquisition 150 of FieldMonitor units per data acquisition 36 (3 FieldMonitor units = 1 TDXnet CP) of Snapshot Note: 1 Snapshot DAQ per Enterprise of configurable online/scanning points (includes Trendmaster Pro and communication processor points) per data acquisition 2500 total combined online/scanning points of configurable points per enterprise: 45,000 (Limited only by the maximum number of points per data acquisition station) Data Historian Maximum Limits (Process Data Only) Mid-Range Server 5,000 configured tags/daq server 2,000 events/second/daq server SQL Server on Mid-Range Server 5000 events/second High Range Server (requires 4GB RAM) 25,000 tags/daq server 10,000 events/second/daq server SQL Server on High Range Server (requires 4 GB RAM) 25,000 events/second Maximum trend file length: Unlimited; dependent on available system hard drive space. of system/alarm FOR REFERENCE ONLY Specifications and Ordering Information Page 4 of 10

5 events per data acquisition Unlimited; dependent on available system hard drive space. of concurrent viewable events: 10,000 events viewable within event list. Network Support: Ethernet Network Transport Protocols: TCP/IP Display Plots The following plots can be selected from stored data, Alarm Event Data, or Baseline Data. Display can be configured to show only the applicable plots for any given application package. Current Values Bargraph Machine Train Diagram Alarm/System Event List Rotor Stator Profile Rotor Shape Hydro Air Gap Phasor Ordering Information Step /00 System /00 AXX BXX-CXX A Order Type 0 1 New Order (CD, Key, Binder) 0 2 Expansion Order (CD & Key) 9 8 Replacement Licenses (Key) 9 9 Update (CD) (Note: One set of manuals will be shipped with each new order. Includes: the System 1 Software User's Guide, System 1 Software Installation Quick Start Guide, and the System 1 Software Operations Quick Start Guide.) B Option Type Note: Choose up to 10 different packages from Table 4 (CM&D Application Packages) and Table 5 (System Extenders). These packages must be ordered via the 3010/00 catalog number under the B option in this step. They cannot be ordered via their own internal catalog numbers. Trend / Multivariable Trend Option 1 Tabular List Option 2 Timebase (with option for superposition of baseline data) Orbit / Timebase (with option for superposition of baseline data) Orbit (with option for superposition of baseline Option 10 data) C Option Quantity Shaft Average Centerline Option 1 Quantity (1-10) Spectrum / Full Spectrum (with option for superposition of baseline data) Option 2 Quantity (1-10) X vs. Y Waterfall / Full Waterfall Polar/Acceptance Region Bode Cascade / Full Cascade Option 10 Quantity (1-10) Step 2 Software (3010/01) Reciprocating plots Note: Option A is for information only and is the value chosen under Step 1. Rod Position Maps Exhaust Gas Temperature (EGT) Performance Map A Order Type 0 1 New Order (CD, Key, Binder) 0 2 Expansion Order (CD & Key) 9 8 Replacement Licenses (Key) FOR REFERENCE ONLY Specifications and Ordering Information Page 5 of 10

6 9 9 Update (CD) B License Protection Type 0 0 None 0 1 USB 0 2 Floppy C Customer Type 0 1 Non OEM 0 2 OEM Step 3 See Table 4 for Application Packages and Table 5 for System Extenders. These packages and extenders must be ordered via the 3010/00 catalog number under the B option in step 1. They cannot be ordered via their own internal catalog numbers. Table 4 CM&D Application Packages Turbo Machinery (3010/05) Scope: Per machine case (Note: Collection of Dynamic Points requires ordering additional enabler licenses or required hardware for the Data Source.) A Application B Data Source C Type 0 1 Steam Turbine /TDI 0 0 Standard 0 2 Industrial Gas Turbine 0 3 Aero Derivative Gas Turbine 0 4 Centrifugal 0 5 Axial 0 6 Screw s /TDe Dynamic Points per Case 0 3 TDXnet Dynamic Points per Case FMIM Dynamic Points per Case DM2K Upgrade w/ Active TSA 1 1 DM2K Upgrade w/ Active TSA - 1 Dynamic Point 0 7 Fan / Blower 1 2 DM2K Upgrade w/ Active TSA - 2 Dynamic Points 0 8 Expander/ Power Turbine 1 3 DM2K Upgrade w/ Active TSA - 3 Dynamic Points 0 9 Pump 2 0 DM2K Upgrade no Active TSA 1 0 Gearbox 2 1 DM2K Upgrade no Active TSA - 1 Dynamic Point 1 1 Electric Motor 2 2 DM2K Upgrade no Active TSA - 2 Dynamic Points 1 2 Generator / Exciter 9 9 Other 2 3 DM2K Upgrade no Active TSA - 3 Dynamic Points Integral Gear (3010/08) Scope: Per Unit A Application 0 1 Standard IG B Number of Stages X X 1 to 20 C Data Source /TDI /TDe 0 3 TDXnet FMIM Hydro Turbines (3010/14) Scope: Per Hydro Turbine A Application B Pkg Options C Data Source 0 1 Conventional 0 1 Hydro Turbine Only /TDI 0 2 Pumped Storage 0 2 Generator Only /TDe 9 9 Other 0 3 Turbine/Generator 0 3 TDXnet Electrical Equipment (3010/15) Scope: Per Asset A Equipment Type B Data Source 0 1 Electric Motor 0 1 GE Multilin (license for 1 Multilin, provides a device connection) 0 2 Generator / Exciter 0 3 Transformer Wind Turbine (3010/16) Scope: Per Wind Turbine A Data Source 0 1 TrendMaster Pro (includes 20 OPC and 10 TM points) Fired Equipment (3010/18) Scope: Per Boiler (up to 20 points) A Equipment Type B Data Source 0 1 Coal Fired Boilers /TDI 0 2 OPC DA 0 3 DDE 04 Modbus FOR REFERENCE ONLY Specifications and Ordering Information Page 6 of 10

7 Reciprocating s (3010/25) Scope: Per + per Throw A Package B Throws C Data Source 0 2 Advanced X X 1 to /TDI /TDe 0 3 TDXnet (limited functionality) Machine Performance (3010/31) Scope: Per Machine Case (up to 20 points) A Application B Calc Engine C Data Source 0 1 Process 0 0 Performance Display only 0 2 Gas Turbine 0 1 Bently Performance Note: 3001/31 must be ordered if this option is ordered. 0 0 None 0 1 OPC DA 0 3 Steam Turbine 0 2 DDE 0 4 Generator 0 3 Modbus 0 5 Pump 0 4 Mark VI GSM 0 6 Feed Heater 0 7 Condenser 0 8 Chillers 0 9 Heat Exchanger 1 0 Turbo Expander 9 9 Other BOP Portable Data (3010/40) Scope: Point Block Packages A Qty Points BOP Trendmaster Pro (3010/45) Scope: Per Enterprise A Data Source 0 1 TrendMaster Pro (50 points) Data Historian (3010/50) Scope: Per point Note: See Historian Maximum Limits under Specifications for computer recommendations and limits. A Historian Points B Data Source OPC DA DDE Modbus (System 1 DAQ is the master. Clients must be slaves.) Mark VI GSM Note 1: Includes: Display, Configuration, DAQ Connections Manager and SmartNotifier Licenses. Note that all on-line packages require MS SQL Standard, which must now be ordered through the 3010/11 C option. You will need one Client Access License (CAL) per client computer. Any computer with a System 1 client, DAQ, or Web Display Server software connecting to a System 1 database running on SQL Server Standard or Enterprise editions needs to have one Client Access License (CAL) each. Table 5 System Extenders Decision Support Studio (3010/35) Package includes: Decision Support Studio Client, Decision Support Manager, RuleDesk Pro, Rule Test Suite, Rule Documentation, Rev Control, and Notification Wizard. Scope: per Computer / User license A Type 0 1 Static data only 0 2 Static and dynamic data A Type Rule Logic Results (3010/33) Package includes: a block of rule logic results. Scope: per Enterprise Rule Logic Results CMMS Interfaces (3010/41) Package includes: Ability to link to CMMS asset, view work history, Manual work request, & Automated work request. Scope: Per DAQ Computer / Server A CMMS Type 0 1 MRO MAXIMO 0 2 SAP earlier than version SAP version 4.7 FOR REFERENCE ONLY Specifications and Ordering Information Page 7 of 10

8 A Type Event Relay Card Software (3010/42) Package includes: Event relay card software Scope: Per DAQ Server. (Order the card via 3010/11 M01) 0 1 Event Relay Card Software Data Exporters (3010/55) Package includes: Specific data exporter for system Scope: Per DAQ Computer / Server A Exporter Type 0 1 OPC 0 2 DDE 0 3 OLE Automation DSM Modbus Exporter (3010/56) Package includes: Modbus Exporter Software Scope: per tag A Number of Tags The Bearing Expert (3010/85) Package includes: The Bearing Expert Software. (Software works with System 1 Configuration. Install on the Configuration computer.) A License Quantity Scope: Per User License 0 1 See The Bearing Expert License Agreement 3010/11-AXX-BXX-CXX-DXX-EXX-FXX-GXX-HXX-IXX- JXX-KXX-LXX-MXX-NXX-OXX A B 0 6 Mid-Range Server DAQ (Rack, Rack Keyboard only, No Monitor) 3, 5, Mid-Range Server DAQ (Rack, No Keyboard/Drawer, No Monitor) 3, Hi-Perf Server DAQ (Rack, Rack Keyboard only, No Monitor) 3, 5, 7, Hi-Perf Server DAQ (Rack, No Keyboard/Drawer, No Monitor) 3, 7, 9 Monitor 0 0 No Monitor XVGA Monitor TFT Flat Panel Monitor TFT Flat Panel Monitor C Microsoft SQL Server (For Servers Only) None D E 0 1 Standard SQL 5 Client Access Licenses 0 2 Standard SQL 10 Client Access Licenses Printer 0 0 No Printer V Laser (Duplex, Parallel, and USB) V Laser (Duplex, Parallel, and USB) V Laser (Duplex, Parallel, USB, and Ethernet) V Laser (Duplex, Parallel, USB, and Ethernet) V Color Laser (USB) V Color Laser (USB) V Color Laser (USB and Ethernet) V Color Laser (USB and Ethernet) Time Synchronization 0 0 No Time Synchronization 0 1 Client Software (One license) System 1 Workstation/Platform (NO MONITOR 1 0 Client Software & NTP Time Server INCLUDED) 2 0 IRIG-B Time Card 0 0 No Workstation/Platform F Serial Communication Card (For Servers Only) Professional Workstation (No Monitor) No Serial Communication Card 0 2 Mid-Range Server DAQ (Tower, No Monitor) 3,9 0 1 RS232 Serial Communication Card 0 3 Mid-Range Server DAQ (Rack, Rack 0 2 RS422/485 Serial Communication Card Keyboard/Drawer, No Monitor) 3, 4, 9 G Network Interface Card Hi-Perf Server DAQ (Tower, No Monitor) 3, 7, No Network Interface Card 0 5 Hi-Perf Server DAQ (Rack, Rack Keyboard/Drawer, No Monitor) 3, 4, Dual Port NIC (For Servers Only) Single Port NIC (For Workstations Only) 10 FOR REFERENCE ONLY Specifications and Ordering Information Page 8 of 10

9 H Redundant Components (For Servers Only) None 0 3 Gold Level B Number of Years 0 1 Redundant Power Supply Note: One year of Bronze level support is included with the initial 0 2 Redundant Cooling Fan Kit 0 3 Redundant Power Supply & Cooling Fan Kit 0 1 One (1) Year product purchase so ordering this option with the initial order will provide additional year(s) of support. I UPS 0 2 Two (2) Years 0 0 No UPS 0 3 Three (3) Years V 1440VA RACK 2U (NA) 0 4 Four (4) Years V 1440VA TOWER (NA) 0 5 Five (5) Years J V 1500VA TOWER (INT'L) System 1 Demo Package (Version 5.0) Second Processor Card (For Servers Only) /99-AXX 0 0 No Second Processor Card K 0 1 Second Processor Card for the Midrange DAQ Integration Platform A Demonstration Software 0 1 Initial Purchase 9 9 Update Sound Adapter and Speakers 0 0 No Sound Adapter and Speakers Accessories 0 1 Sound Adapter and Speakers / System 1 Software Operations Quick Start Guide (Non-OEM/OEM) L Backup Device (For Servers Only) No Backup Device 0 1 Internal Tape Backup M Event Relay (For Servers Only) No Event Relay Hardware 0 1 Event Relay Hardware N Additional Memory (For Servers Only) No additional memory Gbyte additional memory Gbytes additional memory O Remote Access 6 (For Servers Only) No Remote Access offering 0 2 Citrix Server (w/ 5 Users) and MS TS CALs 0 4 Citrix CAL 5 Users and MS TS CALs 0 5 MS TS CAL 5 Users Note: Computer does not come with a CD or DVD writer. If backup capability is needed, the internal tape backup and/or DVD Writer should be ordered. System 1 Technical Support Plan 3010/20-AXX-BXX A Supporting Services 0 0 None 0 1 Bronze Level Note: Bronze level is included in initial purchase for one year of support. 0 2 Silver Level / System 1 Software Installation Quick Start Guide (Non-OEM/OEM) / System 1 Software User's Guide (Non- OEM/OEM) Note: Each new order includes each of these manuals. For Decision Support Studio Developer ordering information, see part number Footnotes: 1 When ordering the additional network card, note that the mid-range and high-end servers provide 4 available network ports. Ordering an additional card will provide 6 network ports and is not supported on the same purchase order line item. 2 This workstation can be ordered for Snapshot systems with 2000 or fewer points, or for a Display or Configuration workstation. 3 When ordering a server computer, you must determine whether the midrange or high-end computer will be appropriate. If the system will have more than 6 Communication Processors or more than 1500 online or scanning points you must order the high-end server option. 4 The Rack Keyboard/Drawer option should be ordered for the rack mount server when using the integrated keyboard/drawer and adjustable rail rack option kit in a non-bently Nevada cabinet. 5 The Rack Keyboard only option should be ordered for the rack mount server when using the standard keyboard with built-in mouse in a Bently Nevada cabinet. 6 You cannot order Citrix when ordering the workstation computer. If Citrix is ordered with the high-performance server, you must also order at least one additional GB of RAM (option N01 or N02). 7 When ordering the high performance server to run DAQ and Citrix, the server will only support up to 6 Communication Processors and no more than 1500 online or scanning points. 8 For Server Only options are not supported in the workstation computer. FOR REFERENCE ONLY Specifications and Ordering Information Page 9 of 10

10 9 Note that there is only one free PCI-X slot for accessory cards in the high-performance and mid-range servers. The other available PCI-X slot is used for the modem, which comes standard with the server. 10 For Workstations Only options are not supported in the server computers. PERFORMANCE, System 1, Actionable Information and Trendmaster are trademarks of General Electric Company in the United States and other countries. MAXIMO is a registered trademark of MRO Software, Inc. The Bearing Expert is a trademark of INTERNATIONAL SOURCE INDEX INC. Citrix is a trademark of Citrix Systems, Inc General Electric Company. All rights reserved. Bently Nevada, Snapshot, Bently DOCUVIEW, TDXnet, RuleDesk, FieldMonitor, Bently Modbus is a registered trademark of Schneider Electric. Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation in the United States and/ or other countries. FOR REFERENCE ONLY Specifications and Ordering Information Page 10 of 10

System 1 * Version 6.7

System 1 * Version 6.7 System 1 * Version 6.7 Optimization and Diagnostics Software Description System 1 * Software is a patented, modular machinery management platform for process and equipment optimization, condition monitoring

More information

System 1 * Version 6.87

System 1 * Version 6.87 System 1 * Version 6.87 Optimization and Diagnostics Software Description System 1 * Software is a patented, modular machinery management platform for process and equipment optimization, condition monitoring

More information

System 1 * Version 6.81

System 1 * Version 6.81 System 1 * Version 6.81 Optimization and Diagnostics Software Description System 1 * Software is a patented, modular machinery management platform for process and equipment optimization, condition monitoring

More information

System 1* Condition Monitoring and Diagnostic Software. Premium Package

System 1* Condition Monitoring and Diagnostic Software. Premium Package System 1* Condition Monitoring and Diagnostic Software Bently Nevada* Asset Condition Monitoring Premium Package The System 1 Premium Package represents GE Bently Nevada s flagship online condition monitoring

More information

VM600 CMS Software. VM600 Series Software for Condition Monitoring System (CMS) FEATURES DESCRIPTION

VM600 CMS Software. VM600 Series Software for Condition Monitoring System (CMS) FEATURES DESCRIPTION VM600 Series Software for Condition Monitoring System (CMS) FEATURES Configuration and operation of VM600 hardware (CMC16 and IOC16T cards) Automatic data acquisition and storage Limit exceedance checking

More information

Condition Monitoring and Maintenance Systems. Condition Monitoring for Industrial Applications

Condition Monitoring and Maintenance Systems. Condition Monitoring for Industrial Applications Condition Monitoring and Maintenance Systems Condition Monitoring for Industrial Applications A Complete Solution Condition Monitoring and Maintenance Systems Presentation Objectives Overview of CMMS Commitment

More information

Combined Cycle Control Overview

Combined Cycle Control Overview Combined Cycle Control Overview Introduction The Combined Cycle (CC) solution provides for the control and monitoring of a typical CC power plant in a cost effective, preengineered package. Basic Architecture

More information

Technical Training Solutions

Technical Training Solutions GE Energy Measurement & Control Solutions Technical Training Solutions GE imagination at work Introduction All GE Measurement & Control Solutions product training is conducted by our core group of customer

More information

System 1* Software version 6.5

System 1* Software version 6.5 System 1* Software version 6.5 Simpler to use, simpler to install, simpler to maintain yet more powerful ollowing its release in 2001, System 1 software is today installed at thousands of locations worldwide,

More information

DATA PROCESSING SOFTWARE

DATA PROCESSING SOFTWARE DATA PROCESSING SOFTWARE UPGRADE OF PROTECTION SYSTEM MMS6000 DIAGNOSTIC DATAMONITOR CONDITION MONITORING EARLY FAULT DETECTION PREDICTIVE MAINTENANCE MMS 6850 1/7 R 2/2011 MMS 6850 DM DATA MANAGER Data

More information

Item Minimum Required Recommended Notes

Item Minimum Required Recommended Notes Carestream Dental strongly adheres to compliance with Microsoft Windows operating systems and hardware compatibility (HCL), which can be found at www.microsoft.com/whdc/hcl/default.mspx. Only operating

More information

Intelligent Vibration Monitoring

Intelligent Vibration Monitoring Diagnostic Systems Condition Based Monitoring Diagnostic Systems Condition Based Monitoring Intelligent Vibration Monitoring efector Octavis for real-time vibration monitoring Solutions for Predictive

More information

CAMAvision v18.5.x System Specification Guide 7/23/2014

CAMAvision v18.5.x System Specification Guide 7/23/2014 The computer industry is very fast moving, with larger and faster technologies supplanting previous hardware releases within six to nine months. Some of the specifications listed may no longer be available,

More information

Purpose... 3. Computer Hardware Configurations... 6 Single Computer Configuration... 6 Multiple Server Configurations... 7. Data Encryption...

Purpose... 3. Computer Hardware Configurations... 6 Single Computer Configuration... 6 Multiple Server Configurations... 7. Data Encryption... Contents Purpose... 3 Background on Keyscan Software... 3 Client... 4 Communication Service... 4 SQL Server 2012 Express... 4 Aurora Optional Software Modules... 5 Computer Hardware Configurations... 6

More information

Rugged and open to your applications

Rugged and open to your applications Rugged and open to your applications Magelis industrial PCs Opti PC, Smart, Smart+, Compact ipc, Smart BOX, Compact BOX, Flex PC BOX, and idisplay Windows XP TM Compact Flash Flash disk Hard disk Magelis

More information

Sage BusinessWorks Accounting 2013 System Standards

Sage BusinessWorks Accounting 2013 System Standards Sage BusinessWorks Accounting 2013 System Standards Hardware Standards (all editions): Laser or high-speed ink jet printer Notes: Multi-purpose printers: Sage BusinessWorks functions correctly with most

More information

QuickSpecs. HP IP Console Switch with Virtual Media Overview

QuickSpecs. HP IP Console Switch with Virtual Media Overview Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various

More information

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools Terminal Server Software and Hardware Requirements Datacolor Match Pigment Datacolor Tools January 21, 2011 Page 1 of 8 Introduction This document will provide preliminary information about the both the

More information

Minimum Hardware Specifications Upgrades

Minimum Hardware Specifications Upgrades Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs Eclipse TM treatment planning system Hardware V 11.0 1 TPS Version 11.0 Minimum Hardware Specifications [DELL OS supported upgrade

More information

Insight Advanced Workstation

Insight Advanced Workstation Technical Specification Sheet Document No. 149-333P25 October 29, 2015 Insight Advanced Workstation Figure 1. Insight Advanced Main Menu. The Insight Advanced Workstation transforms a personal computer

More information

EnerVista TM Viewpoint Monitoring v7.10

EnerVista TM Viewpoint Monitoring v7.10 EnerVista TM Viewpoint Monitoring v7.10 Guideform Specifications July 7, 2014 Page 1 of 14 1 - Product Overview 1.1 Viewpoint Monitoring Scope EnerVista Viewpoint Monitoring is an easy to setup, powerful

More information

CMS Central Monitoring System

CMS Central Monitoring System General In This Section CMS for Windows CMS Hardware CMS Functional Spec Relational Database Monitoring Interface Communication Network CMS Central Monitoring System General CMS Central Monitoring System

More information

Machinery condition monitoring software

Machinery condition monitoring software VIBex Machinery condition monitoring software Optimize productivity of your facilities VIBex is a state-of-the-art system dedicated to online vibration-based condition monitoring and diagnostics of rotating

More information

Stuart Gillen. Principal Marketing Manger. National Instruments stuart.gillen@ni.com. ni.com

Stuart Gillen. Principal Marketing Manger. National Instruments stuart.gillen@ni.com. ni.com Stuart Gillen Principal Marketing Manger National Instruments stuart.gillen@ New Enterprise Solution for Condition Monitoring Applications NI InsightCM Enterprise NI History of Condition Monitoring Order

More information

HC-6950. Emission Protected Security Workstation

HC-6950. Emission Protected Security Workstation Emission Protected Crypto AG / 6950-e-2.ppt / DA-HQ / 0004 / 1 PC and Workstation Risks Security Risks: Unauthorized change of data (Sabotage, Viruses) Unauthorized use of data Data loss (deletion) Physical

More information

Enhancing Business Performance using Integrated Visibility and Big Data

Enhancing Business Performance using Integrated Visibility and Big Data Enhancing Business Performance using Integrated Visibility and Big Data Manish Sharma Marketing Leader GE Energy Management Manish.Sharma1@ge.com Photograph of Speaker ARC Advisory Group GE Energy Management

More information

Global System Requirements 103-00994-009

Global System Requirements 103-00994-009 Global System Requirements 103-00994-009 Information in this documentation is subject to change without notice and does not represent a commitment on the part of LUMEDX Corporation. The software described

More information

How To Use Safety System Software (S3)

How To Use Safety System Software (S3) SPECIFICATION DATA Safety System Software (S3) APPLICATION Safety System Software (S 3 ) is a robust, full featured configuration, diagnostic, programming and real-time monitoring package for integrators

More information

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER TECHNICAL SPECIFICATIONS Communication Server 1000 Telephony Manager 3.2 Communication Server 1000 Telephony Manager 3.0 Communication

More information

AXIS 262+ Network Video Recorder

AXIS 262+ Network Video Recorder 31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,

More information

System Requirements for LUMEDX Hosted Solutions 103-01268-005

System Requirements for LUMEDX Hosted Solutions 103-01268-005 System Requirements for LUMEDX Hosted Solutions 103-01268-005 Information in this documentation is subject to change without notice and does not represent a commitment on the part of LUMEDX Corporation.

More information

WinCon-8000. Programmable Automation. Controller

WinCon-8000. Programmable Automation. Controller Programmable Automation Controller Introduction The is a leading edge embedded platform with Intel Strong ARM CPU running the Windows CE.NET operating system. When compared to the standard Windows OS,

More information

SCADA Questions and Answers

SCADA Questions and Answers SCADA Questions and Answers By Dr. Jay Park SCADA System Evaluation Questions Revision 4, October 1, 2007 Table of Contents SCADA System Evaluation Questions... 1 Revision 4, October 1, 2007... 1 Architecture...

More information

TRIDENT7 ELEMENT MANAGEMENT SUITE

TRIDENT7 ELEMENT MANAGEMENT SUITE TRIDENT7 ELEMENT MANAGEMENT SUITE Enablence is a market leader in optical device technology and its Systems Division is a driving force in Fiber-To- The-Premises (FTTP) optical access technology. We have

More information

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW I/A Series SOFTWARE Product Specifications Logo I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 The I/A Series Intelligent SCADA Platform takes the traditional SCADA Master Station to a new

More information

PC & EMBEDDED CONTROL TRENDS

PC & EMBEDDED CONTROL TRENDS PC & EMBEDDED CONTROL TRENDS Bjoern Falke, Phoenix Contact Inc., Harrisburg, PA Abstract - The trend to reduce machine size and cost while increasing productivity requires new approaches to control systems.

More information

SPECIFICATIONS FOR HARDWARE/ SOFTWARE PROCUREMENT USAID SMALL GRANT PROGRAM MUNICIPALITY OF VIDIN, BULGARIA. Prepared for.

SPECIFICATIONS FOR HARDWARE/ SOFTWARE PROCUREMENT USAID SMALL GRANT PROGRAM MUNICIPALITY OF VIDIN, BULGARIA. Prepared for. SPECIFICATIONS FOR HARDWARE/ SOFTWARE PROCUREMENT USAID SMALL GRANT PROGRAM MUNICIPALITY OF VIDIN, BULGARIA Prepared for Prepared by Tassos Bellesis ICMA East European Regional Housing Sector Assistance

More information

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control

More information

Minimum Hardware Specifications Upgrades

Minimum Hardware Specifications Upgrades Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs ARIA for Medical Oncology, & ARIA for Radiation Oncology Version 13.0 1 ARIA Version 13.0 Minimum Hardware Specifications Minimum:

More information

DMS-10101, Computer Equipment

DMS-10101, Computer Equipment Overview Effective dates: September 2005 - August 2006. This Specification describes the procedures for providing desktop microcomputers, laptop microcomputers, printers, and internet service for use on

More information

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in

More information

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable

More information

GE Measurement & Control. System 1 * Optimization and Diagnostic Platform

GE Measurement & Control. System 1 * Optimization and Diagnostic Platform GE Measurement & Control System 1 * Optimization and Diagnostic Platform System 1* Overview 述 An asset optimization and diagnostic platform 台 System 1 is GE Energy s patented software platform for real-time

More information

Profit Tools for Trucking General System Requirements. Requirements For Hardware, Network, Software and Communications

Profit Tools for Trucking General System Requirements. Requirements For Hardware, Network, Software and Communications Revised 01/02/14 Profit Tools for Trucking General System Requirements Requirements For Hardware, Network, Software and Communications Hardware and Network Requirements: CLIENTS 1. Practical Minimum Client

More information

DCS Data and communication server

DCS Data and communication server 8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With

More information

ABB PSPS Erich Steinmann; Generator control-2013

ABB PSPS Erich Steinmann; Generator control-2013 ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise

More information

EnerVista Viewpoint Monitoring

EnerVista Viewpoint Monitoring EnerVista Viewpoint Monitoring Easy to Use Monitoring and Data Recording EnerVista Viewpoint Monitoring is an easy to setup, powerful and simple to use data monitoring and recording software application

More information

WP-8849. WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).

WP-8849. WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller). Tu Sitio de Automatización! WP-8149 WP-8449 Introduction: WP-8849 WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller). It equips a

More information

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com Arun Veeramani Principal Marketing Manger National Instruments New Enterprise Solution for Condition Monitoring Applications NI InsightCM Enterprise NI History of Condition Monitoring Order Analysis Toolkit

More information

How To Build A Scada System

How To Build A Scada System SECTION 17902 SCADA SYSTEMS PART 1 - GENERAL 1.01 SCOPE OF WORK A. The work of this section shall be performed by a qualified System Integrator and includes providing and installing SCADA computer system

More information

ProfessionalPLUS Station Software Suite

ProfessionalPLUS Station Software Suite January 2013 Page 1 All you need to configure, control, and diagnose your plant is available on the ProfessionalPLUS Station Global database, architected for flexibility and scalability Powerful, graphical

More information

CollectMax System Requirements

CollectMax System Requirements CollectMax System Requirements www.collectmax.com Workstation Requirements Listed below are both the minimum and recommended workstation configurations for using CollectMax. CPU Minimum 1.6 GHz Pentium

More information

Local PlantVisor. PlantWatch. Remote PlantVisor

Local PlantVisor. PlantWatch. Remote PlantVisor PlantVisor Sistema Local PlantVisor PlantWatch Remote PlantVisor Solutions for: Data recording HACCP Printout Alarm management Tele Maintenance Powerful & integrated for Convenience Stores Petrol Station

More information

System Requirements for LUMEDX Hosted Solutions 103-01268-003

System Requirements for LUMEDX Hosted Solutions 103-01268-003 System Requirements for LUMEDX Hosted Solutions 103-01268-003 Information in this documentation is subject to change without notice and does not represent a commitment on the part of LUMEDX Corporation.

More information

On-line Machine Condition Monitoring [The CMS System]

On-line Machine Condition Monitoring [The CMS System] On-line Machine Condition Monitoring [The CMS System] Strategic monitoring control your costs Avoid unplanned downtime Monitor your plant stoppers Early warning maintains profit Efficient and profitable

More information

Terminal Services for InTouch 7.1/7.11. Terminal Services for InTouch 7.1/7.11 PRODUCT POSITION PRODUCT DATASHEET

Terminal Services for InTouch 7.1/7.11. Terminal Services for InTouch 7.1/7.11 PRODUCT POSITION PRODUCT DATASHEET Terminal Services for InTouch 7.1/7.11 PRODUCT POSITION Terminal Services for InTouch 7.1/7.11 PRODUCT DATASHEET Terminal Services for InTouch 7.1/7.11 provides manufacturing users with all the benefits

More information

s y s t e m r e q u i r e m e n t s

s y s t e m r e q u i r e m e n t s s y s t e m r e q u i r e m e n t s System Requirements describe minimum and recommended standards for using Dentrix G4. Exceeding the minimum standards The may result in better system performance. Note:

More information

v1 System Requirements 7/11/07

v1 System Requirements 7/11/07 v1 System Requirements 7/11/07 Core System Core-001: Windows Home Server must not exceed specified sound pressure level Overall Sound Pressure level (noise emissions) must not exceed 33 db (A) SPL at ambient

More information

XWEB EVO Supervisor and Monitoring Systems. November 2014

XWEB EVO Supervisor and Monitoring Systems. November 2014 Supervisor and Monitoring Systems November 2014 XWEB EVO Supervisor and Monitoring Systems for the management of Retail field and HVAC/R applications MAIN APPLICATIONS Hypermarkets Petrol Stations Supermarkets

More information

LOWER TOTAL COST OF OWNERSHIP & INCREASED PRODUCTIVITY

LOWER TOTAL COST OF OWNERSHIP & INCREASED PRODUCTIVITY InTouch 9.0 for Terminal Services b Lower Total Cost of Ownership b Increased Productivity b Flexible Software Deployment Visualize Analyze Optimize PRODUCT HIGHLIGHTS Multiple Platforms and Devices Ease

More information

Enterprise Edition Technology Overview

Enterprise Edition Technology Overview Enterprise Edition Technology Overview The Scholastic Achievement Manager, SAM, is the management system and technology platform for all Scholastic Enterprise Edition (EE) applications. Previous versions

More information

ProfessionalPLUS Station Software Suite

ProfessionalPLUS Station Software Suite Feb-07 Page 1 All you need to configure, control, and diagnose your plant is available on the ProfessionalPLUS Station. Global database, architectured for flexibility and scalability Powerful engineering

More information

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation. V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation. REVISION A DATE: 10/01/2009 CA3000 Software Installation Procedure Continental Access and

More information

I/A Series Information Suite AIM*DataLink

I/A Series Information Suite AIM*DataLink PSS 21S-6C4 B3 I/A Series Information Suite AIM*DataLink AIM*DataLink AIM*DataLink provides easy access to I/A Series real-time data objects and historical information from Windows-based applications.

More information

pro Time & Attendance System

pro Time & Attendance System pro Time & Attendance System 1 4 7 * 2 5 8 0 3 6 9 # pro An Integrated Punch-to-Paycheck System TouchStation TS100 Terminal Employees clock in using their fingerprint. PC-Click Software Employees clock

More information

Online Condition Monitoring Reaps Benefits for Borealis Porvoo

Online Condition Monitoring Reaps Benefits for Borealis Porvoo Online Condition Monitoring Reaps Benefits for Borealis Porvoo Bengt Bergman Inspection Technician Borealis Polymers Oy Petri Nohynek Sales Application Engineer Bently Nevada* Asset Condition Monitoring

More information

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vibration analysis and monitoring Compact. Powerful. Modern technology. Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device

More information

System Requirements for Microsoft Dynamics GP 9.0

System Requirements for Microsoft Dynamics GP 9.0 Requirements for Microsoft Dynamics GP 9.0 Last Modified 7/5/2007 Posted 4/7/2007 This document describes client system requirements, server recommendations and Terminal Server system requirements for

More information

NETWORK MANAGEMENT SOLUTIONS

NETWORK MANAGEMENT SOLUTIONS N E T S M A R T NETWORK MANAGEMENT SOLUTIONS UNIFY YOUR NETWORK As new and legacy services coexist to support a widening variety of customers, network support presents more technical challenges. This complex,

More information

TEST CHAPTERS 1 & 2 OPERATING SYSTEMS

TEST CHAPTERS 1 & 2 OPERATING SYSTEMS TEST CHAPTERS 1 & 2 OPERATING SYSTEMS True/False Indicate whether the statement is true or false. 1. Changes that you make in virtual machines do not affect your physical computer. 2. The size of a bus

More information

Table of Contents. 2 Getting Started Guide

Table of Contents. 2 Getting Started Guide Table of Contents Welcome... 3 Training & Support... 3 Accessing the online support center... 4 1. System Requirements... 5 2. Installing the Free Evaluation Version... 7 3. Software Download Instructions...

More information

Professional Station Software Suite

Professional Station Software Suite January 2013 Page 1 You can easily engineer and operate your process automation system from the Professional Station Powerful, graphical engineering capabilities Robust and secure plant operations Integrated

More information

Software Table of Contents

Software Table of Contents Software Table of Contents WeighVault...282 VIRTUi /VIRTUi 2...283 PC-Based HMI for iqube /iqube 2 OnTrak...284 Weighbridge Management Software SOFTWARE Looking for product pricing? Please visit www.ricelake.eu

More information

CF Dashboard. Features and Benefits

CF Dashboard. Features and Benefits M-Applications Manual 653 CF Dashboard Section Product Bulletin Issue Date 0601 CF Dashboard The CF Dashboard offering is a customized solution for the telecommunications market and other large enterprises.

More information

White Paper ClearSCADA Architecture

White Paper ClearSCADA Architecture White Paper ClearSCADA Architecture ClearSCADA has 3 major components or software applications; the ClearSCADA server, a windows client known as, and a web client known as Webx. The software is designed

More information

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine Software INTERACT MachineLogic The Shortest Distance Between Man and Machine Fully IntegrateYour HMI and PC-Based Control With MachineShop Project Management MachineShop s Project Management is a simple,

More information

M-series Virtual I/O Module 2

M-series Virtual I/O Module 2 DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series

More information

Intel Pentium IV or compatible 1 gigahertz (GHz) or higher processor

Intel Pentium IV or compatible 1 gigahertz (GHz) or higher processor The Patron Edge 3.402 Minimum System Requirements / Last updated 10/5/11 Minimum System Requirements This document lists the required infrastructure to run your Blackbaud. Blackbaud recommends the purchase

More information

MedInformatix System Requirements

MedInformatix System Requirements MedInformatix System Requirements Acentec, Inc. A MedInformatix installation requires a workstation for each user who will access the system and a central server to store and process the data. A large

More information

ALERT AUTOMATED DIAGNOSTIC SOFTWARE

ALERT AUTOMATED DIAGNOSTIC SOFTWARE ALERT AUTOMATED DIAGNOSTIC SOFTWARE AUTOMATED PORTAL ENABLED ACCURATE SEAMLESS INTEGRATION OVER 650 FAULTS 4500 DIAGNOSTIC RULES We are able to monitor the health of all of our machinery across the entire

More information

Kevin Kochirka, ABB Turbine Automation, June 29, 2016. Flexible turbine control retrofits Webinar

Kevin Kochirka, ABB Turbine Automation, June 29, 2016. Flexible turbine control retrofits Webinar Kevin Kochirka, ABB Turbine Automation, June 29, 2016 Flexible turbine control retrofits Webinar Welcome Speaker introduction Kevin Kochirka Sr. Applications Engineer with ABB Inc. Kevin.Kochirka@us.abb.com

More information

Small Business Server Part 1

Small Business Server Part 1 Small Business Server Part 1 Presented by : Robert Crane BE MBA MCP director@ciaops.com Computer Information Agency http://www.ciaops.com Agenda Week 1 What is SBS / Setup Week 2 Using & configuring SBS

More information

Alert, inform, react Aastra Alarm Server

Alert, inform, react Aastra Alarm Server Alert, inform, react Targeted alarming on all communication channels The effective transfer of information is important to increase a company s success and customer satisfaction. Information can be passed

More information

HP Server Console Switch with Virtual Media Overview

HP Server Console Switch with Virtual Media Overview Overview HP's Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow access

More information

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project QUESTIONS & ANSWERS ItB tender 72-09: IT Equipment. Elections Project In lot 1, position 1 - Server for Data Base 1. Q: You order Microsoft Windows Server 2008, 64 bit, Enterprise, License with 25 or more

More information

A guide to CLARiSUITE TM network solutions

A guide to CLARiSUITE TM network solutions Technical FAQ s CLARiSUITE Code Assurance A guide to CLARiSUITE TM network solutions Overview IT infrastructure security, integrity and stability are primary concerns of Videojet and its customers. Management

More information

SCADAvantage Network Topology System software products

SCADAvantage Network Topology System software products Data sheet DS/2101193-EN Rev. AD SCADAvantage Network Topology System software products Basic elements of a SCADAvantage system SCADAvantage has three distinct parts: the, the RTRDB, and the Client. Diagram

More information

WEBs-AX Enterprise Security

WEBs-AX Enterprise Security WEBs-AX Enterprise Security SPECIFICATION DATA APPLICATIONS WEBs-AX Enterprise Security is a comprehensive access control and security management solution, built on a truly open, IP based platform. Developed

More information

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static

More information

Recommended Hardware & System Requirements for ProVenueDatabox and ProVenueMax Systems

Recommended Hardware & System Requirements for ProVenueDatabox and ProVenueMax Systems Page 1 of 7 Recommended Hardware & System Requirements for ProVenueDatabox and ProVenueMax Systems Server Overview: The purpose of this document is not to provide a minimum specification but to advise

More information

QuickSpecs. Overview. Compaq Remote Insight Lights-Out Edition

QuickSpecs. Overview. Compaq Remote Insight Lights-Out Edition Overview M ODELS Remote Insight Lights-Out Edition 157866-001 New Remote Insight Lights-Out Edition provides virtual graphical control using any standard browser to your remote or data centre server, giving

More information

STI Hardware Specifications for PCs

STI Hardware Specifications for PCs Local School Fileserver with STIOffice & STIClassroom WIN 1GHz or Higher 512MB 1GB Free Space Windows 2000/2003 Server, Novell Netware v4.11 or greater. Local School Fileserver with STIOffice, STIClassroom

More information

I/A Series Software FoxDPM.com Dynamic Performance Monitor.com

I/A Series Software FoxDPM.com Dynamic Performance Monitor.com I/A Series Software FoxDPM.com Dynamic Performance Monitor.com PSS 21S-4X2 B3 Foxboro s Dynamic Performance Monitor.com (FoxDPM.com) is an advanced decision support tool which combines process data from

More information

WINSCRIBE HARDWARE SPECIFICATIONS

WINSCRIBE HARDWARE SPECIFICATIONS WINSCRIBE HARDWARE SPECIFICATIONS Technology Overview proposes centralization of resources by providing a networked solution that fits into the existing framework of your server environment with minimal

More information

OfficeServ Application Suite

OfficeServ Application Suite OfficeServ Application Suite Introduction to the standard package The OfficeServ application suite consists of a number of applications designed to enhance the functionality and usability of the Samsung

More information

Electrical Monitoring and Control System Solution. Guideform Specification

Electrical Monitoring and Control System Solution. Guideform Specification Electrical Monitoring and Control System Solution Guideform Specification 1 SYSTEM... 2 1.1 Overview... 2 1.2 System Solution Functional... 2 1.2.1 Monitoring... 2 1.2.2 Power Quality... 4 1.2.3 Cost Allocation

More information

Cisco MCS 7825-H2 Unified CallManager Appliance

Cisco MCS 7825-H2 Unified CallManager Appliance Cisco MCS 7825-H2 Unified CallManager Appliance This product is no longer being sold and might not be supported. Read the End-of-Life Notice to learn about potential replacement products and information

More information

Parallels Desktop 4 for Windows and Linux Read Me

Parallels Desktop 4 for Windows and Linux Read Me Parallels Desktop 4 for Windows and Linux Read Me Welcome to Parallels Desktop for Windows and Linux build 4.0.6576. This document contains the information you should know to successfully install Parallels

More information

APC Enterprise KVM Switches

APC Enterprise KVM Switches APC Enterprise KVM Switches Introduction You need more than point access products. You need a system that provides more control, flexibility and scalability than ever before. Systems that reduce your Mean

More information