ZORBAX Columns for Analytical HPLC ZORBAX Eclipse XDB HPLC Columns
|
|
- Gavin White
- 7 years ago
- Views:
Transcription
1 ZORBAX HPLC Columns The Agilent ZORBAX columns C8, C8, and Phenyl are designed to provide good peak shape for basic, acidic, and neutral compounds over the ph range -9. This wide useable ph range allows superior method development flexibility with one family of columns. columns can be used for initial method development at low ph (-) and will provide high resolution and excellent peak shape of all types of compounds. The same column can be used for method development in the mid ph (6-8) region. In the mid ph region, residual silanols are more active and tailing interactions are more likely. To overcome these interactions, columns are extra Densely Bonded and double endcapped through a proprietary process to cover as many active silanols at possible. The result is superior peak shape of basic compounds from ph -9. columns are available in C8, C8, and Phenyl bonded phases for selectivity optimization of most separations. StableBond (for low ph), Bonus-RP (for low and mid ph), and Extend-C8 (from low to high ph) columns are available as additional selectivity choices. Extra Densely Bonded and Double Endcapped Bonded Phase A Good Peak Shape over a Wide ph Range with ZORBAX ph Excellent first choice for method development Excellent peak shape for bases, acids, and neutrals Wide useable ph range ph -9 High purity silica Long lifetime with extra dense bonding and double endcapping ZORBAX columns provide good peak shape over a wide ph range and are an excellent first choice for method development from ph -9. B ph 7 Column: -C8 4.6 x50 mm, 5 µm P/N Flow Rate:.5 ml/min Temperature: 40 C Figure A: ph.0 Mobile Phase: 75% 5 mm Phosphate Buffer ph.0: 5% ACN Sample:. Maleate. Doxylamine. Chlorpheniramine 4. Triprolidine 5. Diphenhydramine Figure B: ph 7.0 Mobile Phase: 90% 0 mm phosphate ph 7.0: 0% ACN Sample:. Procainamide. N-acetylprocainamide. N-propionylprocainamide
2 ZORBAX HPLC Columns Column Stability Testing at ph and 60 C K of Amitriptyline ZORBAX SB-C8 P/N ZORBAX -C8 P/N Competitive C8 Column Volumes of Mobile Phase (X000) Column Stability Testing at ph 7.0 Competitive C8 SIL-type After 86 Column Volumes Column: 4.6 x 50 mm, 5 µm Purge Conditions: Mobile Phase: 70% 50 mm NaAc-HCl, ph.0 0% ACN Retention Test Conditions Mobile Phase: 65% Methanol 5% Water Flow Rate:.0 ml/min Temperature: 60 C Sample: Tricyclic Antidepressants columns are stable over a wide ph range. At low ph, Eclipse, an end capped column is extremely stable and shows equivalent stability to a non-endcapped column, SB-C8, at ph. The columns were purged with a ph mobile phase at 60 C. Then they were tested with a strongly basic compound to determine if the endcapping or bonded phase had been hydrolyzed from the silica surface. The column was very stable, as shown by the consistency of the retention of amitriptyline over the,000 column volumes of the test. Another endcapped column shows less stability under these same conditions. Double endcapping, dense bonding and the durable Rx-Sil particles (sol-type) combine to provide long lifetime at ph 7 when compared to single endcapped sil-gel columns used here. The conditions used for this test high temperature (60 C) and high salt concentration (50 mm), accelerate the dissolution of silica, causing premature failure of the sil-gel type column. -C8 P/N Sol-type After 84 Column Volumes Column: 4.6 x 50 mm, 5 µm Mobile Phase: 60% ACN 40% 50 mm Phosphate Buffer, ph 7.0 Flow Rate:.5 ml/min Temperature: 60 C Sample: Tricyclic Antidepressants. Uracil. Nortriptyline. Doxepin 4. Amitriptyline 5. Trimipramine
3 ZORBAX HPLC Columns Selectivity Changes for Basic Compounds with and Stable Bond Double Endcapped -C8 P/N Keep your Agilent 00 Series HPLC system running at peak performance To ensure that your LC pump, manual injection valves, autosampler, and detectors work at maximum efficiency, request a copy of Maintaining your Agilent 00 Series HPLC System. This 55-page resource will help you maximize uptime and increase productivity. To request this guide: Go to Publication number EN StableBond SB-C8 P/N Selectivity Optimization with Bonded Phases -Phenyl P/N Columns: Rapid Resolution 4.6 x 75 mm,.5 µm Mobile Phase: 70% 5 mm NaH PO 4, ph.0 0% Methanol Flow Rate:.0 ml/min Temperature: 5 C Sample:. Barbital. Sulfamethoxazole. Caffeine and StableBond columns are based on the same silica but have different bonding and endcapping. Therefore, they can have very different selectivity for the same sample under the same conditions, as this example shows. -C8 P/N C8 8 P/N Column: 4.6 x 50 mm,.5 µm Mobile Phase: 5% H O: 85% MeOH Flow Rate:.0 ml/min Temperature: 0 C Detection: UV 0 nm Sample:. Oxybenzone. Padimate-O. Ethylhexylsalicylate min This separation of sunscreens on all three bonded phases C8, C8 and Phenyl shows that different bonded phases can be used to optimize a separation. While all three bonded phases provide an adequate separation, the -Phenyl provides a different peak elution order and a much shorter overall analysis time. All three bonded phases also provide excellent peak shape with no mobile phase additives.
4 ZORBAX HPLC Columns ZORBAX Column Ordering Information Column Size Particle XDB-C8 XDB-C8 XDB-Phenyl Description (mm) Size (µm) USP L USP L7 USP L Standard Columns Semi-Prep 9.4 x Analytical 4.6 x Analytical 4.6 x Analytical 4.6 x Rapid Resolution 4.6 x Rapid Resolution 4.6 x Rapid Resolution 4.6 x Rapid Resolution 4.6 x Rapid Resolution HT 4.6 x Rapid Resolution HT, /pk 4.6 x Solvent Saver.0 x Solvent Saver.0 x Solvent Saver Plus.0 x Solvent Saver Plus.0 x Solvent Saver Plus.0 x Narrow Bore. x Narrow Bore. x Narrow Bore RR*. x Narrow Bore RR. x Narrow Bore RR. x Narrow Bore RR. x Narrow Bore RRHT. x Narrow Bore RRHT, /pk. x MicroBore RR.0 x MicroBore RR.0 x MicroBore RR.0 x MicroBore Guard Cartridges, /pk.0 x Guard Cartridges, 4/pk 4.6 x Guard Cartridges, 4/pk. x Guard Hardware Kit PrepHT Cartridges (endfittings required for use) PrepHT Cartridge. x PrepHT Cartridge. x PrepHT Cartridge. x PrepHT Cartridge. x PrepHT Cartridge. x PrepHT Guard Cartridge 7 x Guard Hardware Kit PrepHT Endfittings () (required for use) Agilent Cartridge Columns (requires cartridge holder ) Analytical 4.6 x Analytical 4.6 x Rapid Resolution 4.6 x Solvent Saver Plus.0 x Guard Cartridges, 0/pk 4.0 x Cartridge Holder (continued on next page) 4
5 ZORBAX HPLC Columns ZORBAX Column Ordering Information (continued) Column Size Particle XDB-C8 XDB-C8 XDB-Phenyl Description (mm) Size (µm) USP L USP L7 USP L High Throughput (HT) Cartridge Columns (requires Hardware Kit ) Rapid Resolution Cartridge 4.6 x Rapid Resolution Cartridge, /pk 4.6 x Rapid Resolution Cartridge 4.6 x Rapid Resolution Cartridge, /pk 4.6 x Rapid Resolution Cartridge. x Rapid Resolution Cartridge, /pk. x Rapid Resolution Cartridge. x Rapid Resolution Cartridge, /pk. x Rapid Resolution HT Cartridge 4.6 x Rapid Resolution HT Cartridge, /pk 4.6 x Rapid Resolution HT Cartridge 4.6 x Rapid Resolution HT Cartridge, /pk 4.6 x Rapid Resolution HT Cartridge 4.6 x Rapid Resolution HT Cartridge, /pk 4.6 x Rapid Resolution HT Cartridge. x Rapid Resolution HT Cartridge, /pk. x Rapid Resolution HT Cartridge. x Rapid Resolution HT Cartridge, /pk. x Rapid Resolution HT Cartridge. x Rapid Resolution HT Cartridge, /pk. x Hardware Kit for High Throughput Columns Capillary Glass-Lined Columns Capillary 0.5 x Capillary 0.5 x Capillary RR 0.5 x Capillary RR 0.5 x Capillary 0. x Capillary 0. x Capillary RR 0. x Capillary 0.5 x Capillary 0. x Call for custom orders *RR: Rapid Resolution.5 µm columns **RRHT: Rapid Resolution HT.8 µm columns Configurations not shown are available upon request. For more information on these and other columns consult the Agilent Web site at Take the guesswork out of guard column selection Order your guard columns at the same time as your analytical columns. An online compatibility guide shows which guard cartridges are compatible with each Agilent HPLC column type. For easy ordering, this guide shows pictures and part numbers of guard column hardware, with links to the online store. Go to: ZORBAX Column Specifications Bonded Phase Pore Size Surface Area Temp. Limits ph Range Endcapped Carbon Load ZORBAX -C8 80Å 80 m /g 60 C Double 0% ZORBAX -C8 80Å 80 m /g 60 C Double 7.6% ZORBAX -Phenyl 80Å 80 m /g 60 C Double 7.% 5
Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC
Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Agilent ZORBAX Column Selection Guide for HPLC Here it is your single
More informationThermo Scientific Syncronis HPLC Columns. Technical Manual
Thermo Scientific Syncronis HPLC Columns Technical Manual Thermo Scientific Syncronis HPLC Columns When developing a new method, one of the most important goals for the chromatographer is to achieve a
More informationAgilent ZORBAX HPLC Column Selection Guide for Biotechnology. Resolution that Lasts
Agilent ZORBAX HPLC Column Selection Guide for Biotechnology Resolution that Lasts Bioanalytical Chromatography from Agilent Technologies The variety and number of bioanalytical HPLC applications continue
More informationUnique Bonding Chemistry
columns Acclaim HPLC Columns Reversed-phase silica columns for pharmaceutical, nutraceutical, environmental, food, and life science applications in HPLC. High hydrophobicity, low polarity phases LC/MS
More informationProtocol: HPLC (amino acids)
Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain
More informationHPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
More informationComparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns
omparison of the Reversed-Phase Selectivity of Solid ore HPL olumns M. Dolci, L. Pereira, Thermo Fisher Scientific, Runcorn, heshire, UK Technical Note 20788 Key Words Accucore, solid core, column characterization,
More informationHPLC Column Comparison Screening Study for Reversed Phase Columns
HPLC Column Comparison Screening Study for Reversed Phase Columns Carmen T. Santasania, Eric M. Snyder, Matilal Sarker, and Tracy L. Ascah Supelco, 595 North Harrison Road, Bellefonte, PA 16823, USA T403058
More informationAnalytical Test Report
Analytical Test Report Customer: Address (City, State): Purchase Order: Report Number: Project Number: Date Received: Date of Report: Test Location: Boulder, CO. Assay: Part Number: Amino Acids by HPLC
More informationStrength in Technology HPLC COLUMNS. Product Guide
Strength in Technology HPLC COLUMNS Product Guide [ m V ] Cefadroxil 3 5 0 3 0 0 UniverSil C18 250x4.6mm 5µm Cefachlor Surface Area - 175m 2 /g 2 5 0 Pore Size - 140Å Voltage 2 0 0 Cefradine % Carbon -
More informationThermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance
Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid
More informationAgilent BioHPLC Column Selection Guide YOUR REFERENCE GUIDE TO THE ANALYSIS OF BIOPHARMACEUTICALS AND BIOMOLECULES
Agilent BioHPLC Column Selection Guide YOUR REFERENCE GUIDE TO THE ANALYSIS OF BIOPHARMACEUTICALS AND BIOMOLECULES Table of Contents Biocolumn Selection Guidelines... 1 Biomolecule Separations... 4 UHPLC/HPLC
More informationHypercarbColumns 100% porous graphitic carbon for extended separation capabilities
Columns 00% porous graphitic carbon for extended separation capabilities Exceptional retention of very polar analytes Separates structurally related substances ph stable from 0 to Ideal for high temperature
More informationHow To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
More informationApplication Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation
Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA
More informationMethod Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates
Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION
More informationTransfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs
Agilent Application Solution Transfer of a USP method for prednisolone from normal phase PLC to SFC using the Agilent 126 Infinity ybrid SFC/UPLC System Saving time and costs Application Note Pharmaceutical
More informationERDOSTEINE - MONOGRAPH.
STRUCTURAL FORMULA (±1S-(2-[N-3-(2-oxotetrahydro thienyl)]acetamido)-thioglycolic acid) C 8 H 11 NO 4 S 2 M.W. = 249.307 DESCRIPTION Color : White to ivory white Appearance : Microcrystalline powder SOLUBILITY
More informationTCI Chiral HPLC Column
TCI Chiral HPLC Column ~ Spiral Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. Chromatography Department 29 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new
More informationAmino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
More informationProtein Separation Technology
[ ] Protein Separation Technology Protein Separation Technology The analysis and characterization of protein samples requires the detection of small chemical differences between large molecules. Most often
More informationA Guide to HPLC and LC-MS Buffer Selection
A Guide to HPLC and LC-MS Buffer Selection HPLC Columns John Dolan Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated HPLC Columns For Performance, Selectivity
More informationThe Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC
The Essential CHROMacademy Guide Mobile Phase Optimization Strategies for Reversed Phase HPLC Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge
More informationDetermination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS
Summary: Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS UCT Part Numbers: CUNAX226 - Clean-Up C8+NAX, 2mg/6mL BETA-GLUC- ml Beta-Glucuronidase Enzyme, liquid form SLAQ1ID21-3UM -
More informationAutomated Method Development Utilizing Software-Based Optimization and Direct Instrument Control
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,
More informationTamsulosin Hydrochloride Capsules
. nal Revision Bulletin Official October 1, 2011 Tamsulosin 1 standard solution, and shake well. Centrifuge at 1500 rpm for 10 min, and use the supernatant, passing it if Tamsulosin Hydrochloride Capsules
More informationGuide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
More informationCONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
More informationStandard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS
Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLCDAD and HPLCMS/MS Jongheon Shin College of Pharmacy Seoul National University Summary The standard analytical
More informationThe Theory of HPLC. Gradient HPLC
The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims
More informationCapillary HPLC Introduction
Capillary HPLC Introduction Capillary HPLC Liquid chromatography/mass spectrometry, LC/MS, is a revolutionary tool in the chemical and life sciences. LC/MS is accelerating chemical research by providing
More informationApplication Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.
Application Note Determination of Amino acids by UHPLC with automated PA- Derivatization by the Autosampler Category Bio Analysis Matrix - Method UHPLC Keywords Proteinogenic Amino acids, Canonical Amino
More informationElectrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
More informationThe Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides
More informationInnovative vs Traditional
And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late
More informationA Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC
A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC HPLC Columns David Carr Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated
More informationHigh sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK Background Unilabs YBS are a bioanalytical CRO based in York (Uk) Copenhagen
More informationfor SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns
for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)
More informationSolid Core Technical Compendium
150-C4 150-C18 Phenyl-Hexyl XL-C18 PFP 150-Amide-HILIC C0 Urea-HILIC Phenyl-X HILIC Polar Premium C8 XL-C8 aq C18 RP-MS Solid Core Technical Compendium Want fast, high-resolution separations, plus a range
More informationUltra Performance LC with Photo Diode Array Detection for the Development of Methods: Impurity Profiling and Long Term Stability Studies
Ultra Performance LC with Photo Diode Array Detection for the Development of Methods: Impurity Profiling and Long Term Stability Studies Pittsburgh Conference Orlando, FL 14MAR06 Observations The pressure
More informationLC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
More informationAn Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at
More informationSample Preparation Using Solid Phase Extraction
Sample Preparation Using Solid Phase Extraction Dr. Shulamit Levin Based on: Yung-Fong (Henry) Cheng Waters Corporation 34 Maple Street Milford, MA 0757 Present at EAS'98 Workshop Troubleshooting of Sample
More informationThermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
More informationHow To Use An Agilent 9 Infinity Lc
Agilent 9 Infinity LC Infinitely more powerful 9 Agilent 9 Infinity LC Infinitely more powerful. With more than enough power to handle any HPLC or UHPLC challenge, the advanced technology in the Agilent
More informationA Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
More informationIAM Chromatography. HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction
IAM Chromatography Immobilized Artificial Membrane (IAM) technology is an innovative approach to chromatography in which the chromatographic surface emulates the lipid environment of the cell membrane.
More informationSIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
CHAPTER 5 SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 5 Simultaneous determination of Telmisartan
More informationFast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
More informationReversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension
International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination
More informationChapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
More informationThermo Scientific HyperSep Solid Phase Extraction Method Development Guide
chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo
More informationWaters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
More informationExtraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
More informationOasis HLB Cartridges and 96-Well Plates
CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION
More informationAgilent 1200 Series LC Systems and Modules
Agilent 1200 Series LC Systems and Modules 2 Agilent 1200 Series Pure Liquid Chromatography Agilent Technologies has taken its world leading LC system and made it even more flexible, smarter and ultimately
More informationHPLC Basics, Equipment, and Troubleshooting
HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,
More informationBulk Materials for Preparative and Process Chromatography
Bulk Materials for Preparative and Process Chromatography Silica Based HPLC Bulk Media Characteristics Available in both reversed and normal phases High chemical stability for low leaching High loading
More informationCertificate of Analysis
National Institute of Standards & Technology Certificate of Analysis Standard Reference Material 870 Column Performance Test Mixture for Liquid Chromatography This Standard Reference Material (SRM) is
More informationApplication Note. Determination of 17 AQC derivatized Amino acids in baby food samples. Summary. Introduction. Category Bio science, food Matrix
Application Note Determination of 17 AQC derivatized Amino acids in baby food samples Category Bio science, food Matrix Baby food Method UHPLC Keywords Proteinogenic amino acids, canonical amino acids,
More informationHigh-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
More informationAMINO ACID ANALYSIS By High Performance Capillary Electrophoresis
AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis Analysis of Amino Acid Standards Label free analysis using the HPCE-512 ABSTRACT Capillary electrophoresis using indirect UV detection
More informationAnalysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection
Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection Application Note Food Testing & Agriculture Authors Edgar Naegele and Thomas
More informationAffi-Prep Protein A Matrix Instruction Manual
Affi-Prep Protein A Matrix Instruction Manual Catalog Numbers 156-0005 156-0006 Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules, CA 94547 LIT-230 Rev B Table of Contents Section 1 Introduction...1
More informationThe basic division explosives for forensic purposes is shown in Fig. 1
Isolation, concentration and determination of post blast residua by liquid chromatography with DAD detector capillary electrophoresis with DAD detector Firearm fumes (gunshot residua, GSR) - various metallic
More information23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
More informationAnalysis of Vegetable Oils by High Performance Liquid Chromatography
Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia
More informationAdvantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites
Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Carmen T. Santasania and David S. Bell SUPELCO, 595 North Harrison Road, Bellefonte, PA 16823 T404045 GUS Abstract
More informationA VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water
A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box
More information[ Care and Use Manual ]
Analytical columns and cartridges i. Introduction Waters offers a large selection of analytical columns and cartridges packed with silica-based packing materials. Follow this instruction sheet to obtain
More informationThis handbook presents the basic principles of reversed-phase HPLC for the
Third Edition, 2002 This handbook presents the basic principles of reversed-phase HPLC for the analysis and purification of polypeptides. For further details regarding reversed-phase HPLC separations of
More informationHPLC Troubleshooting Guide
HPLC Troubleshooting Guide Click on sections below to go directly to that section of the Troubleshooting Guide HPLC Troubleshooting Uwe D. Neue, Waters Corporation 1. Column Life-Time 2. Variable Retention
More informationDetermination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis
Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis UCT Product Numbers: CSDAU26: 2mg / 6mL SPE cartridge SLDA1ID21-3UM:
More informationProcess Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
More informationEKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS
EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction
More information[ Care and Use Manual ]
ACQUITY UPLC CSH Columns Contents I. Getting started a. Column Connectors b. Column Installation c. Column Equilibration d. ecord Installation e. Initial Column Efficiency Determination f. VanGuard Pre-Columns
More informationHow To Use An Acquity Qda Detector
Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector
More informationUHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
More informationIFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.
IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The
More informationSPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac.
SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 i.chianella.1998@cranfield.ac.uk Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation
More informationLipid analysis in Food Industry
Lipid analysis in Food Industry by HPLC-ELSD Brochure Lpd-1 The Best Column and Detector for Superior Lipid Analysis Introduction The characterization of the lipid fraction present in fats and oils became
More informationLUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)
October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for
More informationSolid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE
Solid Phase Extraction Products PAGE: 1 Introduction of Solid Phase Extraction (SPE) SPE has been used increasingly in chemical analysis and purification broadly, and become the most popular technology
More informationDionex IonPac AS19-4µm
Total Thermo Scientific Dionex IonPac AS9-4µm Column Product Manual P/N: September 203 Part of Thermo Fisher Scientific Product Manual for Dionex IonPac AS9-4µm Column Dionex IonPac AG9-4µm Capillary Guard
More informationDrospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date
Drospirenone and Ethinyl Estradiol Tablets Type of Posting Revision Bulletin Posting Date 31 July 2015 Official Date 01 August 2015 Expert Committee MonographsSmall Molecules 4 Reason for Revision Compliance
More informationß-CYCLODEXTRIN SYNONYMS
ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications
More informationAutomation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
More informationSize Exclusion Chromatography
Size Exclusion Chromatography TOYOPEARL Resins for SEC TOYOPEARL TOYOPEARL TOYOPEARL HW-55 TOYOPEARL HW-65 TOYOPEARL TOSOH BIOSCIENCE TOSOH BIOSCIENCE LLC 56 Keystone Drive Montgomeryville, PA 896-967
More informationFacile HPLC Separation of Peptides: Resolution of Chiral/Achiral Single Amino Acid Analogues using Teicoplanin-based Chiral Stationary Phases
Facile PLC Separation of Peptides: Resolution of Chiral/Achiral Single Amino Acid Analogues using Teicoplanin-based Chiral Stationary Phases J.T. Lee and Thomas E. Beesley Advanced Separation Technologies
More informationBringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer www.paclp.com Background Biodiesel offers an alternative to fossil diesel fuel & contributes to the reduction
More informationFast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation
Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.
More informationMEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
More informationPurification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
More informationMonoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry
Monoclonal ntibody Fragment Separation and haracterization Using Size Exclusion hromatography oupled with Mass Spectrometry uthors Haiying hen Katherine McLaughlin Sepax Technologies, Inc. 5 Innovation
More information