Enterprise SSD Competitive Analysis
|
|
|
- Rodney Barber
- 9 years ago
- Views:
Transcription
1 Gary Tressler and Dean Sciacca IBM Corporation August
2 Introduction Methodology Performance Response Time Power Consumption Write Amplification Life Span Summary Agenda August
3 Introduction IBM is driving MLC SSD adoption for Enterprise storage Five industry Enterprise MLC SSDs were characterized SATA3 or SAS2 interface (6Gbps) 200 or 400GB usable MLC Flash capacity SSDs evaluated were prototype or engineering samples Firmware may not have been fully optimized August
4 Enterprise SSD Characterization Methodology Characterization Platform PC with high performance CPU, DDR3 DRAM Windows 7 (64-bit) operating system LSI 9212 host bus adapter Apply VDBench 5.03 Exerciser SSDs in raw mode (no file system) Use 4KB aligned writes/reads (512B mode) 4KB transfer size for random workloads 128K transfer size for sequential workloads Preconditioning Initial 24-hour write random/sequential workload Each individual measurement has its own preconditioning cycle Preconditioning durations are based on the time necessary for SSD performance to stabilize against a given workload Each measurement is the average performance for an extended interval August
5 Enterprise MLC SSD Performance Random Access Performance 600 Sequential Access Performance K IOPS MB/s SSD1 SSD2 SSD3 SSD4 SSD Read 100:1 Read 1:1 Write 100:1 Write 1:1 70/30 R/W 2:1 50/50 R/W 2:1 0 Read 100:1 Read 1:1 Write 100:1 Write 1:1 70/30 R/W 2:1 50/50 R/W 2:1 Random reads observed in the 35-55KIOPs range, and random writes in the 5-40KIOPs range Sequential reads observed in the MBps range, with sequential writes in the MBps range Notable performance improvements observed over prior generation Mixed read-write mode performance not optimized in certain cases Note: Data compression ratios defined for each test (e.g.: 100:1, 1:1 and 2:1) August
6 SSD Random Performance vs. Data Compressibility 4K IOPS Random 70/30 Read/Write Workload vs Data Compressibility (queue depth=32) SSD1 SSD2 SSD3 SSD4 SSD :1 4:1 2:1 4:3 1:1 Compressibility Most SSDs characterized showed consistent performance vs. data compressibility Data compression techniques now under widespread development across industry August
7 SSD Response Time Characterization SSD response time is critical for overall Enterprise system performance and customer satisfaction A transaction type workload is applied Mixed random read and write, 4KB and 8KB Response time is measured as a function of queue depth Average maximum response time is the average of the maximum response times in thirty 10-second intervals Competitive response times require optimization of latency and frequency of various SSD background operations Response times are not adequately specified Average read/write and average maximum read/write response time parameter specifications would provide users with valuable information August
8 Average and Average Maximum Response Time vs. Queue Depth Average Response Time vs Queue Depth Avg Max Response Time vs Queue Depth Avg. Response Time (ms) SSD1 SSD2 SSD3 SSD4 SSD5 Avg Max Response Time (ms) SSD1 SSD2 SSD3 SSD4 SSD Queue Depth Queue Depth Large variation in average response times observed further optimization required Frequency and latency of SSD non-data operations are key to reducing average maximum response times Note: Data compression of 5:1 applied August
9 Enterprise SSD Power Consumption Power consumption is an increasingly important SSD attribute Existing system requirements limit available power Heat generation reduces intrinsic component reliability and can cause SSDs to fault SSD power is rising with improving SSD performance Primarily due to higher Flash bandwidth and increasing number of active Flash die during write operations Ongoing challenge require innovation Thermal interface materials Advanced throttling techniques August
10 Enterprise SSD Power Consumption by Workload 12 Average Power Usage by Workload 10 Power (W) SSD1 SSD2 SSD3 SSD4 SSD5 2 0 Idle Sequential Read Sequential Write Random Read Random Write Sequential 50/50 R/W Random 70/30 R/W Random 50/50 R/W SSD write power generally 1.5X higher than read power High idle power observed in certain cases Note: Data compression of 2:1 applied August
11 SSD Write Amplification Enterprise SSD Competitive Analysis SSD write amplification (WA) is the ratio of amount of data written to Flash to the amount of write data requested by the host Enterprise MLC can sustain an order of magnitude more program-erase cycles than standard consumer grade MLC Example - 30K or greater Enterprise MLC vs. 3K consumer MLC WA is a key SSD controller architectural parameter to assess Enterprise SSD lifespan for particular usage cases Disk Life Span = P/E cycles* Drive Capacity(MB) WA* Write Performance (MB/s)* Duty Cycle August
12 Enterprise SSD Write Amplification (WA) 5 4 Write Amplification :1 0 2:1 50 1:1 100 Data Compressibility Note: Results reflect random access View of industry Enterprise SSD write amplification status (8 suppliers) WA is a critical SSD architecture parameter with inverse relationship to life span August
13 Enterprise SSD Life Span Characterization Numerous industry Enterprise SSDs under long term continuous write testing at IBM Effort in early stage initiated 1Q11 Approx. 10% of specified SSD usable life evaluated to date Results reflective of specified life span expected by 3Q12 Monitoring Flash block retirement vs. time No clear method identified for accelerated testing No observed SSD performance changes thus far August
14 Summary Suppliers are now developing next generation Enterprise MLC SSDs targeted at 6Gbps (SATA3/SAS2) Notable performance improvements observed over prior generation SSD response time is critical metric for overall Enterprise system performance and customer satisfaction Opportunities for improved specifications exist SSD power characteristics have increased significantly and will present an ongoing systems challenge Thermal mitigation innovation required Write amplification is a key controller architectural parameter to assess SSD life span for particular usage cases With increased performance, write amplification and capacity must scale to maintain life span targets August
Lab Evaluation of NetApp Hybrid Array with Flash Pool Technology
Lab Evaluation of NetApp Hybrid Array with Flash Pool Technology Evaluation report prepared under contract with NetApp Introduction As flash storage options proliferate and become accepted in the enterprise,
The Why and How of SSD Performance Benchmarking. Esther Spanjer, SMART Modular Easen Ho, Calypso Systems
The Why and How of SSD Performance Benchmarking Esther Spanjer, SMART Modular Easen Ho, Calypso Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
Host Memory Buffer (HMB) based SSD System. Forum J-31: PCIe/NVMe Storage Jeroen Dorgelo Mike Chaowei Chen
Host Memory Buffer (HMB) based SSD System Forum J-31: PCIe/NVMe Storage Jeroen Dorgelo Mike Chaowei Chen Agenda Market Trends in Client SSD Introducing DRAMless architecture for SATA & PCIe Host Memory
Application-Focused Flash Acceleration
IBM System Storage Application-Focused Flash Acceleration XIV SDD Caching Overview FLASH MEMORY SUMMIT 2012 Anthony Vattathil [email protected] 1 Overview Flash technology is an excellent choice to service
Understanding endurance and performance characteristics of HP solid state drives
Understanding endurance and performance characteristics of HP solid state drives Technology brief Introduction... 2 SSD endurance... 2 An introduction to endurance... 2 NAND organization... 2 SLC versus
Intel Solid-State Drive 320 Series
Intel Solid-State Drive 320 Series Enterprise Server/Storage Application Product Specification Addendum Form Factors: 1.8-inch and 2.5-inch Capacity: 80/160/300 GB (1.8-inch) 40/80/120/160/300/600 GB (2.5-inch)
OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance
OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance by George Crump, Lead Analyst! When non-volatile flash memory-based solid-state drives (SSDs) were introduced, the protocol
Bringing Greater Efficiency to the Enterprise Arena
Bringing Greater Efficiency to the Enterprise Arena Solid State Drive Samsung Semiconductor Inc. Tony Kim @ CES 2011 Flash Forward: @ Flash CES Memory 2011 Storage Solutions What is SSD? Solid State Drive
Best Practices for SSD. Performance Measurement. Accuracy, Consistency, Repeatability. Main Goals of Enterprise. Performance Measurement
Best Practices for SSD Performance Measurement Doug Rollins, Senior Strategic Applications Engineer Micron Technology, Inc. Technical Marketing Brief SSDs have pronounced write-history sensitivity, which
How To Write On A Flash Memory Flash Memory (Mlc) On A Solid State Drive (Samsung)
Using MLC NAND in Datacenters (a.k.a. Using Client SSD Technology in Datacenters) Tony Roug, Intel Principal Engineer SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA.
Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card
Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card Version 1.0 April 2011 DB15-000761-00 Revision History Version and Date Version 1.0, April 2011 Initial
Important Differences Between Consumer and Enterprise Flash Architectures
Important Differences Between Consumer and Enterprise Flash Architectures Robert Sykes Director of Firmware Flash Memory Summit 2013 Santa Clara, CA OCZ Technology Introduction This presentation will describe
SSDs and RAID: What s the right strategy. Paul Goodwin VP Product Development Avant Technology
SSDs and RAID: What s the right strategy Paul Goodwin VP Product Development Avant Technology SSDs and RAID: What s the right strategy Flash Overview SSD Overview RAID overview Thoughts about Raid Strategies
Qualification Process for Enterprise SSDs
Qualification Process for Enterprise SSDs Jeffrey A Fritzjunker IBM Rochester, MN Manager, Power Systems Storage Device Qualification Santa Clara, CA 1 Abstract IBM has qualified several generations of
Intel Solid State Drive Toolbox
3.3.5 Document Number: 325993-026US Intel technologies features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending
A Close Look at PCI Express SSDs. Shirish Jamthe Director of System Engineering Virident Systems, Inc. August 2011
A Close Look at PCI Express SSDs Shirish Jamthe Director of System Engineering Virident Systems, Inc. August 2011 Macro Datacenter Trends Key driver: Information Processing Data Footprint (PB) CAGR: 100%
Comparison of Hybrid Flash Storage System Performance
Test Validation Comparison of Hybrid Flash Storage System Performance Author: Russ Fellows March 23, 2015 Enabling you to make the best technology decisions 2015 Evaluator Group, Inc. All rights reserved.
Scaling from Datacenter to Client
Scaling from Datacenter to Client KeunSoo Jo Sr. Manager Memory Product Planning Samsung Semiconductor Audio-Visual Sponsor Outline SSD Market Overview & Trends - Enterprise What brought us to NVMe Technology
Intel Solid State Drive Toolbox
3.3.6 Document Number: 325993-027US Intel technologies features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending
QuickSpecs. PCIe Solid State Drives for HP Workstations
Introduction Storage technology with NAND media is outgrowing the bandwidth limitations of the SATA bus. New high performance Storage solutions will connect directly to the PCIe bus for revolutionary performance
Solid State Storage in a Hard Disk Package. Brian McKean, LSI Corporation
Solid State Storage in a Hard Disk Package Brian McKean, LSI Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may
Solid State Drive Technology
Technical white paper Solid State Drive Technology Differences between SLC, MLC and TLC NAND Table of contents Executive summary... 2 SLC vs MLC vs TLC... 2 NAND cell technology... 2 Write amplification...
QuickSpecs. HP Z Turbo Drive
Overview Introduction Storage technology with NAND media is outgrowing the bandwidth limitations of the SATA bus. New high performance storage solutions will connect directly to the PCIe bus for revolutionary
SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.
Overview Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers
QuickSpecs. HP Solid State Drives (SSDs) for Workstations. Overview
Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers to higher
SUPERTALENT PCI EXPRESS RAIDDRIVE PERFORMANCE WHITEPAPER
RAIDDrive PCIe SSD Performance SUPERTALENT PCI EXPRESS RAIDDRIVE PERFORMANCE WHITEPAPER PCI EXPRESS SOLID STATE DRIVE Copyright 2009, Super Talent Technology. All rights reserved. All trademarks property
Caching Mechanisms for Mobile and IOT Devices
Caching Mechanisms for Mobile and IOT Devices Masafumi Takahashi Toshiba Corporation JEDEC Mobile & IOT Technology Forum Copyright 2016 Toshiba Corporation Background. Unified concept. Outline The first
SNIA Solid State Storage Performance Test Specification. Easen Ho CTO, Calypso Systems, Inc.
SNIA Solid State Storage Performance Test Specification Easen Ho CTO, Calypso Systems, Inc. SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted.
Enterprise Flash Drive
Enterprise Flash Drive A evolução do armazenamento de dados Tutorial sobre as tecnonologias SSD (Solid State Disk) e sua implantação pela engenharia da EMC, denominado EFD (Enterprise Flash Drive), onde
Advantages of Intel SSDs for Data Centres
Advantages of Intel SSDs for Data Centres Executive Summary Most businesses depend on at least one data centre infrastructure to be successful. A highly functioning data centre has several requirements,
DELL SOLID STATE DISK (SSD) DRIVES
DELL SOLID STATE DISK (SSD) DRIVES STORAGE SOLUTIONS FOR SELECT POWEREDGE SERVERS By Bryan Martin, Dell Product Marketing Manager for HDD & SSD delltechcenter.com TAB LE OF CONTENTS INTRODUCTION 3 DOWNFALLS
N8103-149/150/151/160 RAID Controller. N8103-156 MegaRAID CacheCade. Feature Overview
N8103-149/150/151/160 RAID Controller N8103-156 MegaRAID CacheCade Feature Overview April 2012 Rev.1.0 NEC Corporation Contents 1 Introduction... 3 2 Types of RAID Controllers... 3 3 New Features of RAID
SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.
Overview Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers
Deep Dive: Maximizing EC2 & EBS Performance
Deep Dive: Maximizing EC2 & EBS Performance Tom Maddox, Solutions Architect 2015, Amazon Web Services, Inc. or its affiliates. All rights reserved What we ll cover Amazon EBS overview Volumes Snapshots
SATA SSD Series. InnoDisk. Customer. Approver. Approver. Customer: Customer. InnoDisk. Part Number: InnoDisk. Model Name: Date:
SATA SSD Series Customer: Customer Part Number: InnoDisk Part Number: InnoDisk Model Name: Date: InnoDisk Approver Customer Approver Table of contents EverGreen SATA SSD REVISION HISTORY... 4 LIST OF TABLES...
Solid State Drive (SSD) FAQ
Solid State Drive (SSD) FAQ Santosh Kumar Rajesh Vijayaraghavan O c t o b e r 2 0 1 1 List of Questions Why SSD? Why Dell SSD? What are the types of SSDs? What are the best Use cases & applications for
PowerVault MD1200/MD1220 Storage Solution Guide for Applications
PowerVault MD200/MD220 Storage Solution Guide for Applications A Dell Technical White Paper Dell PowerVault Storage Systems Joe Noyola Systems Performance Analysis Group Chuck Colburn Storage Advanced
SSD Write Performance IOPS Confusion Due to Poor Benchmarking Techniques
SSD Write Performance IOPS Confusion Due to Poor Benchmarking Techniques Dominique A. Heger [email protected] www.dhtusa.com Introduction Over the last few years, the proliferation of solid state disk
MS EXCHANGE SERVER ACCELERATION IN VMWARE ENVIRONMENTS WITH SANRAD VXL
MS EXCHANGE SERVER ACCELERATION IN VMWARE ENVIRONMENTS WITH SANRAD VXL Dr. Allon Cohen Eli Ben Namer [email protected] 1 EXECUTIVE SUMMARY SANRAD VXL provides enterprise class acceleration for virtualized
Chronicle: Capture and Analysis of NFS Workloads at Line Rate
Chronicle: Capture and Analysis of NFS Workloads at Line Rate Ardalan Kangarlou, Sandip Shete, and John Strunk Advanced Technology Group 1 Motivation Goal: To gather insights from customer workloads via
Flash Memory Basics for SSD Users
Flash Memory Basics for SSD Users April 2014, Rainer W. Kaese Toshiba Electronics Europe Storage Products Division SSD vs. HDD Enterprise SSD Can write the full capacity 30x per day over lifetime Client/Laptop
Samsung Solid State Drive RAPID mode
Samsung Solid State Drive RAPID mode White Paper 2013 Samsung Electronics Co. Improving System Responsiveness with Samsung RAPID mode Innovative solution pairs advanced SSD technology with cutting-edge
Solid State Technology What s New?
Solid State Technology What s New? Dennis Martin, President, Demartek www.storagedecisions.com Agenda: Solid State Technology What s New? Demartek About Us Solid-state storage overview Types of NAND flash
The Technologies & Architectures. President, Demartek
Deep Dive on Solid State t Storage The Technologies & Architectures Dennis Martin Dennis Martin President, Demartek Demartek Company Overview Industry analysis with on-site test lab Lab includes servers,
NAND Flash Architecture and Specification Trends
NAND Flash Architecture and Specification Trends Michael Abraham ([email protected]) NAND Solutions Group Architect Micron Technology, Inc. August 2012 1 Topics NAND Flash Architecture Trends The Cloud
Speeding Up Cloud/Server Applications Using Flash Memory
Speeding Up Cloud/Server Applications Using Flash Memory Sudipta Sengupta Microsoft Research, Redmond, WA, USA Contains work that is joint with B. Debnath (Univ. of Minnesota) and J. Li (Microsoft Research,
SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.
Overview Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers
Mini PCIe SSD - mpdm. RoHS Compliant. Product Specifications. August 15 th, 2012. Version 1.0
RoHS Compliant Mini PCIe SSD - mpdm Product Specifications August 15 th, 2012 Version 1.0 Apacer Technology Inc. 4 th Fl., 75 Hsin Tai Wu Rd., Sec.1, Hsichih, New Taipei City, Taiwan 221 Tel: +886-2-2698-2888
HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture
WHITE PAPER HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture Based on Microsoft SQL Server 2014 Data Warehouse
Accelerating I/O- Intensive Applications in IT Infrastructure with Innodisk FlexiArray Flash Appliance. Alex Ho, Product Manager Innodisk Corporation
Accelerating I/O- Intensive Applications in IT Infrastructure with Innodisk FlexiArray Flash Appliance Alex Ho, Product Manager Innodisk Corporation Outline Innodisk Introduction Industry Trend & Challenge
Flash-Friendly File System (F2FS)
Flash-Friendly File System (F2FS) Feb 22, 2013 Joo-Young Hwang ([email protected]) S/W Dev. Team, Memory Business, Samsung Electronics Co., Ltd. Agenda Introduction FTL Device Characteristics
SSD Server Hard Drives for IBM
New for 2011! Axiom is introducing a new line of SSD Hot-Swap Server Hard Drives. Our high performance SSD hard drives have been paired with system specific Hot-Swap trays to deliver seamless integration
LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE. Matt Kixmoeller, Pure Storage
LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE Matt Kixmoeller, Pure Storage SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies
Flash 101. Violin Memory Switzerland. Violin Memory Inc. Proprietary 1
Flash 101 Violin Memory Switzerland Violin Memory Inc. Proprietary 1 Agenda - What is Flash? - What is the difference between Flash types? - Why are SSD solutions different from Flash Storage Arrays? -
Serial ATA Flash Drive
RoHS Compliant Serial ATA Flash Drive msata A1 Product Specifications July 10 th, 2014 Version 1.3 Apacer Technology Inc. 1F, No.32, Zhongcheng Rd., Tucheng Dist., New Taipei City, Taiwan, R.O.C Tel: +886-2-2267-8000
LSI MegaRAID FastPath Performance Evaluation in a Web Server Environment
LSI MegaRAID FastPath Performance Evaluation in a Web Server Environment Evaluation report prepared under contract with LSI Corporation Introduction Interest in solid-state storage (SSS) is high, and IT
Samsung Solid State Drive TurboWrite Technology
Samsung Solid State Drive TurboWrite Technology White Paper 213 Samsung Electronics Co. Faster Sequential Write Performance with TurboWrite Technology Accelerated sequential write speeds To improve on
SALSA Flash-Optimized Software-Defined Storage
Flash-Optimized Software-Defined Storage Nikolas Ioannou, Ioannis Koltsidas, Roman Pletka, Sasa Tomic,Thomas Weigold IBM Research Zurich 1 New Market Category of Big Data Flash Multiple workloads don t
Flash Storage: Trust, But Verify
Flash Storage: Trust, But Verify A better, vendor-independent way to analyze flash performance Leah Schoeb, Evaluator Group Peter Murray, Load DynamiX 1 Introductions 2 Speakers Leah Schoeb Senior Partner
Features. SSD370S SATA III 6Gb/s SSD. Advanced Global Wear-Leveling and Block management for reliability
SSD370S SATA III 6Gb/s SSD Due to Ultra-slim (fit the standard dimensions of 2.5 SATA Hard Disk Drives), huge capacity, SATA 6Gb/s speed, and low power consumption, Solid State Drive is the perfect replacement
SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.
Introduction Solid State Drives (SSDs) are fast becoming a real force with respect to storage in the computer industry. With no moving parts, storage is no longer bound by mechanical barriers to higher
Accelerating Server Storage Performance on Lenovo ThinkServer
Accelerating Server Storage Performance on Lenovo ThinkServer Lenovo Enterprise Product Group April 214 Copyright Lenovo 214 LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER
How SSDs Fit in Different Data Center Applications
How SSDs Fit in Different Data Center Applications Tahmid Rahman Senior Technical Marketing Engineer NVM Solutions Group Flash Memory Summit 2012 Santa Clara, CA 1 Agenda SSD market momentum and drivers
Technologies Supporting Evolution of SSDs
Technologies Supporting Evolution of SSDs By TSUCHIYA Kenji Notebook PCs equipped with solid-state drives (SSDs), featuring shock and vibration durability due to the lack of moving parts, appeared on the
Data Center Solutions
Data Center Solutions Systems, software and hardware solutions you can trust With over 25 years of storage innovation, SanDisk is a global flash technology leader. At SanDisk, we re expanding the possibilities
PCIe Storage Performance Testing Challenge
PCIe Storage Performance Testing Challenge Tien Pham SSD Applications Manager Advantest America, Inc. Santa Clara, CA 1 Outline PCIe Storage Test Challenges PCIe Storage Production Test Items And Bottlenecks
Flash at the price of disk Redefining the Economics of Storage. Kris Van Haverbeke Enterprise Marketing Manager Dell Belux
Flash at the price of disk Redefining the Economics of Storage Kris Van Haverbeke Enterprise Marketing Manager Dell Belux We believe that Redefining the Economics of Storage helps businesses achieve their
Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays
Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Database Solutions Engineering By Murali Krishnan.K Dell Product Group October 2009
Data Retention in MLC NAND Flash Memory: Characterization, Optimization, and Recovery
Data Retention in MLC NAND Flash Memory: Characterization, Optimization, and Recovery Yu Cai, Yixin Luo, Erich F. Haratsch*, Ken Mai, Onur Mutlu Carnegie Mellon University, *LSI Corporation 1 Many use
AIX NFS Client Performance Improvements for Databases on NAS
AIX NFS Client Performance Improvements for Databases on NAS October 20, 2005 Sanjay Gulabani Sr. Performance Engineer Network Appliance, Inc. [email protected] Diane Flemming Advisory Software Engineer
CPS104 Computer Organization and Programming Lecture 18: Input-Output. Robert Wagner
CPS104 Computer Organization and Programming Lecture 18: Input-Output Robert Wagner cps 104 I/O.1 RW Fall 2000 Outline of Today s Lecture The I/O system Magnetic Disk Tape Buses DMA cps 104 I/O.2 RW Fall
HP Smart Array Controllers and basic RAID performance factors
Technical white paper HP Smart Array Controllers and basic RAID performance factors Technology brief Table of contents Abstract 2 Benefits of drive arrays 2 Factors that affect performance 2 HP Smart Array
Can Flash help you ride the Big Data Wave? Steve Fingerhut Vice President, Marketing Enterprise Storage Solutions Corporation
Can Flash help you ride the Big Data Wave? Steve Fingerhut Vice President, Marketing Enterprise Storage Solutions Corporation Forward-Looking Statements During our meeting today we may make forward-looking
Solid State Drive Architecture
Solid State Drive Architecture A comparison and evaluation of data storage mediums Tyler Thierolf Justin Uriarte Outline Introduction Storage Device as Limiting Factor Terminology Internals Interface Architecture
Memory Channel Storage ( M C S ) Demystified. Jerome McFarland
ory nel Storage ( M C S ) Demystified Jerome McFarland Principal Product Marketer AGENDA + INTRO AND ARCHITECTURE + PRODUCT DETAILS + APPLICATIONS THE COMPUTE-STORAGE DISCONNECT + Compute And Data Have
Flash & DRAM Si Scaling Challenges, Emerging Non-Volatile Memory Technology Enablement - Implications to Enterprise Storage and Server Compute systems
Flash & DRAM Si Scaling Challenges, Emerging Non-Volatile Memory Technology Enablement - Implications to Enterprise Storage and Server Compute systems Jung H. Yoon, Hillery C. Hunter, Gary A. Tressler
Data Center Storage Solutions
Data Center Storage Solutions Enterprise software, appliance and hardware solutions you can trust When it comes to storage, most enterprises seek the same things: predictable performance, trusted reliability
Managing the evolution of Flash : beyond memory to storage
Managing the evolution of Flash : beyond memory to storage Tony Kim Director, Memory Marketing Samsung Semiconductor I nc. Nonvolatile Memory Seminar Hot Chips Conference August 22, 2010 Memorial Auditorium
As enterprise data requirements continue
Storage Introducing the Dell PERC 6 Family of SAS RAID ControlLers By Bhanu Prakash Dixit Sanjay Tiwari Kedar Vaze Joe H. Trickey III The Dell PowerEdge Expandable RAID Controller (PERC) 6 family of enterprise-class
ISE 820 All Flash Array. Performance Review. Performance Review. March 2015
ISE 820 All Flash Array Performance Review March 2015 Performance Review March 2015 Table of Contents Executive Summary... 3 SPC-1 Benchmark Re sults... 3 Virtual Desktop Benchmark Testing... 3 Synthetic
Flash for Databases. September 22, 2015 Peter Zaitsev Percona
Flash for Databases September 22, 2015 Peter Zaitsev Percona In this Presentation Flash technology overview Review some of the available technology What does this mean for databases? Specific opportunities
Direct NFS - Design considerations for next-gen NAS appliances optimized for database workloads Akshay Shah Gurmeet Goindi Oracle
Direct NFS - Design considerations for next-gen NAS appliances optimized for database workloads Akshay Shah Gurmeet Goindi Oracle Agenda Introduction Database Architecture Direct NFS Client NFS Server
Energy-aware job scheduler for highperformance
Energy-aware job scheduler for highperformance computing 7.9.2011 Olli Mämmelä (VTT), Mikko Majanen (VTT), Robert Basmadjian (University of Passau), Hermann De Meer (University of Passau), André Giesler
Certification Document macle GmbH Grafenthal-S1212M 24/02/2015. macle GmbH Grafenthal-S1212M Storage system
macle GmbH Grafenthal-S1212M Storage system Executive summary After performing all tests, the macle GmbH Grafenthal-S1212M has been officially certified according to the Open-E Hardware Certification Program
Intel RAID RS25 Series Performance
PERFORMANCE BRIEF Intel RAID RS25 Series Intel RAID RS25 Series Performance including Intel RAID Controllers RS25DB080 & PERFORMANCE SUMMARY Measured IOPS surpass 200,000 IOPS When used with Intel RAID
Dynamic Disk Pools Technical Report
Dynamic Disk Pools Technical Report A Dell Technical White Paper Dell PowerVault MD3 Dense Series of Storage Arrays 9/5/2012 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL
IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org
IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator
Flash Fabric Architecture
Flash Fabric Architecture Violin Memory s Flash Fabric Architecture is the foundation for the next generation of enterprise storage Version 2.0 Abstract Purpose- built flash technology impacts data center
Measuring Performance of Solid State Storage Arrays
Technology Insight Paper Measuring Performance of Solid State Storage Arrays Using Data Set and Data Stream Pattern Modeling By Leah Schoeb June 2014 Enabling you to make the best technology decisions
HP Z Turbo Drive PCIe SSD
Performance Evaluation of HP Z Turbo Drive PCIe SSD Powered by Samsung XP941 technology Evaluation Conducted Independently by: Hamid Taghavi Senior Technical Consultant June 2014 Sponsored by: P a g e
Deduplication, Compression and Pattern-Based Testing for All Flash Storage Arrays Peter Murray - Load DynamiX Leah Schoeb - Evaluator Group
Deduplication, Compression and Pattern-Based Testing for All Flash Storage Arrays Peter Murray - Load DynamiX Leah Schoeb - Evaluator Group Introduction Advanced AFAs are a Different Animal Flash behavior