Coal Flow Optimization with B&W PGG s EvenFlow System

Size: px
Start display at page:

Download "Coal Flow Optimization with B&W PGG s EvenFlow System"

Transcription

1 Technical Paper BR-1865 Coal Flow Optimization with B&W PGG s EvenFlow System Authors: B. Hosseininejad T.A. Fuller E.D. Fuller Babcock & Wilcox Power Generation Group. Inc. Barberton, Ohio, U.S.A. A. Murkerson J. Krajna Lakeland Electric, McIntosh Station Lakeland, Florida, U.S.A. H. Bilirgen Lehigh University, Energy Research Center Bethlehem, Pennsylvania, U.S.A. Presented to: Power-Gen International Date: December 13-15, 2011 Location: Las Vegas, Nevada, U.S.A.

2 Coal Flow Optimization with B&W PGG s EvenFlow System B. Hosseininejad T.A. Fuller E.D. Fuller Babcock & Wilcox Power Generation Group, Inc. Barberton, Ohio, U.S.A. A. Murkerson J. Krajna Lakeland Electric, McIntosh Station Lakeland, Florida, U.S.A. H. Bilirgen Lehigh University, Energy Research Center Bethlehem, Pennsylvania, U.S.A. Presented at: Power-Gen International Las Vegas, Nevada, U.S.A. December 13-15, 2011 BR-1865 Abstract Coal flow imbalance is an issue of concern for many pulverized coal-fired boilers in the power generation industry. Achieving balanced coal flow to burners can have a positive impact on carbon monoxide (CO) and nitrogen oxides (NOx) emissions, loss on ignition (LOI) and slagging. For this reason, balancing coal flow is a primary objective of combustion optimization. In collaboration with the Energy Research Center at Lehigh University, Babcock & Wilcox Power Generation Group, Inc. (B&W PGG) has developed a device to control the distribution of coal flow to burners. Key to its development, the device has been proven to accurately control the coal distribution with negligible impact on the primary air flow distribution. B&W PGG has incorporated this advancement into a commercial system known as the EvenFlow coal flow controller. The first utility-scale demonstration of the EvenFlow coal flow controller was recently completed at Lakeland Electric s McIntosh Station. Testing of the system included traditional sampling methods, as well as real-time feedback from other systems. This paper presents an overview of this demonstration project, including installation, testing and results. Introduction Background For pulverized coal-fired boilers, poor coal distribution to the burners can have a significant, negative effect on combustion and emissions. High coal flow to burners can create carbon-rich zones of reducing atmosphere which leads to increased slagging, increased carbon monoxide (CO) emissions, and increased LOI. Burners with too little coal flow can create oxygen-rich zones that may increase nitrogen oxides (NOx) emissions. Further, the parameters that affect coal quality (hardness, moisture, energy content, etc.) may create varying conditions during boiler operation that necessitate online changes to coal flow distribution. Therefore, identifying an online, real-time system to adjust the distribution of coal has been a long sought after goal of many in the fossil power industry. Traditional online coal flow distribution systems involve adjustable restrictions in the burner lines such as variable orifices. However, testing has shown that these systems affect the primary air flow in a pipe significantly more than the coal flow. This could have undesirable and potentially dangerous consequences for combustion. A system that can effectively manipulate the coal flow without greatly affecting the primary air flow would be advantageous. With these issues in mind, B&W PGG collaborated with the Energy Research Center at Lehigh University (ERC) to develop the EvenFlow coal flow controller for pressurized, vertical-spindle pulverizers. The EvenFlow system was developed and tested using computational modeling and laboratory-scale testing at ERC laboratories. At the successful completion of laboratory testing, the system was installed in a B&W Roll Wheel 75G pulverizer at Lakeland Electric s McIntosh Generating Station for utility-scale testing. Development Development of the EvenFlow system began at the ERC s facilities in Bethlehem, Pennsylvania. Initial designs for a flow control element (FCE) were developed and Babcock & Wilcox Power Generation Group 1

3 evaluated using computational modeling techniques. The most promising design underwent physical flow testing in the Pneumatic Conveying Laboratory, shown in Figure 1. Laboratory testing identified the final design criteria for the FCE and demonstrated that a system of FCEs installed in a mill could successfully change coal flow distribution while having a negligible effect on primary air flow. Further development of the EvenFlow system occurred at B&W PGG s headquarters in Barberton, Ohio, to build the FCEs into a complete system for utility-scale pulverizers. Additionally, the laboratory tests were used in combination with computational modeling to identify the neutral position the position at which the FCEs had negligible effect on pulverizer operation. The next phase of the system s development would be testing on a utility boiler. Test site Unit 3 at Lakeland Electric s McIntosh Generating Station is a 350 MW Radiant Boiler designed by B&W PGG. The boiler, shown in Figure 2, was designed to produce 2,510,000 lb/hr of steam at 2640 psig and 1005 F. The boiler has a total of 32 burners located on the front and rear wall. There are four rows of four burners on each wall. The burners are fed by four B&W Roll Wheel 75G pulverizers. Each pulverizer has eight outlet pipes and feeds two consecutive elevations of burners. The EvenFlow system was installed on Mill 31, which feeds the lower two elevations of burners on the rear boiler wall. The EvenFlow system The EvenFlow coal flow controller consists of a number of FCEs that are used to manipulate coal flow to one or more pulverized coal outlet pipes. FCEs can be moved individually or in groups to achieve a balanced coal flow distribution to the burners. The FCEs are installed in the outlet distribution turret of the mill. Each FCE is independently positioned; they can be equipped with electric actuators or adjusted manually. Fig. 2 McIntosh Unit 3. Several designs exist for the EvenFlow system. The exact design used on a given installation depends on the pulverizer s size and the number of coal outlet pipes. For McIntosh Unit 3, B&W PGG supplied a cartridge design. The cartridge design provides a single major component for ease of installation. The cartridge consists of a new coal inlet pipe surrounded by a sealed compartment that houses and protects the device s mechanical components. The cartridge and FCEs are manufactured using a hardened material suitable to withstand the harsh environment inside the pulverizer. The EvenFlow cartridge used at McIntosh is shown in Figure 3. The flow control elements mount to the outside of the cartridge, located in the turret of the pulverizer. The FCEs are positioned using electric actuators with built-in positioners that are located at the top of the cartridge. The actuators are linked to the FCEs through hardware in the cartridge s sealed compartment. Installation The EvenFlow coal flow controller was installed in Mill 31 during a maintenance outage on Unit 3 in February Fig. 1 ERC coal flow test facility. Mechanical Since the EvenFlow cartridge includes a new coal inlet pipe, the existing internal portion of the coal inlet pipe to the pulverizer was removed. The exterior portion of the coal 2 Babcock & Wilcox Power Generation Group

4 Fig. 3 EvenFlow cartridge for Lakeland McIntosh. inlet pipe was disconnected and moved aside for installation. In addition, one of the coal outlet pipes was disconnected and moved aside to provide clearance for the new cartridge. The EvenFlow cartridge was lowered into the place of the former coal inlet pipe, as shown in Figure 4. The cartridge was hoisted above the pulverizer and lowered into place. A flange, located at the top of the cartridge, directly beneath the actuators, was welded to the pulverizer top plate. Once the cartridge was fully lowered and secured, the FCEs were installed on the cartridge from inside the pulverizer. Mounting rods, shown in Figure 5, were installed for the FCEs. The cartridge contained an integral system for lubrication and also required the connection of instrument air lines to maintain the sealed compartment. Electrical/controls The EvenFlow system included a dedicated programmable logic control (PLC) system, which allowed for fully automated adjustment of the FCEs. The PLC system, including a touch screen interface, was completely contained within a single control cabinet. A second cabinet was installed to house power connections and fuses for the actuators. The Fig. 5 FCE mounting rods. two enclosures were mounted on a platform near Mill 31, as shown in Figure 6. Each FCE was independently controlled and positioned using an electric actuator and positioner module. Electrical lines for 110 VAC power and a 4-20 ma position signal were connected from the electrical and control cabinets to the actuators on the top of the pulverizer. The control system was designed to accept manual position inputs from a local touch screen display or remote position inputs (e.g., from an optimization system) for closed-loop control. Testing The EvenFlow system was tested throughout 2010 and 2011 with the intent of evaluating the effect on boiler and pulverizer performance. Specifically, the effects of the system on coal and air flow needed to be analyzed. Procedure To gauge the effects of the EvenFlow system, an accurate and consistent means of coal and air flow measurement was needed. For these purposes, B&W PGG elected to conduct dirty air and coal recovery tests. Lakeland Electric s performance group also conducted several clean air tests. All Fig. 4 EvenFlow cartridge installation. Fig. 6 Electrical/controls cabinets. Babcock & Wilcox Power Generation Group 3

5 tests were conducted using the appropriate ASTM probes and procedures based on those specified in the ASME Power Test Code. All of the tests were conducted using test ports located between five and ten feet beneath the burner elbow in a vertical run, as shown in Figure 7. During tests, the mill feeder speed was set in manual and held at approximately 30.5 tons/hr. Baseline tests During the initial round of testing, several baseline tests were conducted to enable repeatable and consistent results with the manual coal recovery tests. For the baseline tests, all FCEs were placed into the neutral position. Figure 8 displays the coal distribution for each of the baseline tests. Coal distribution was calculated using the following formulas: where bal avg is the average coal mass flow rate, n is the number of coal pipes (8), R i is the coal mass flow rate for a given pipe, and dev i is the percentage deviation from average for a given pipe. As shown in Figure 8, the baseline test results found most samples for each coal pipe to be within a 10% margin. Baseline testing also proved that the system, while in the neutral position, did not have a measureable effect on mill parameters including mill pressure drop, mill motor amps, or fineness. Also noted was that Pipe 7 had relatively high coal flow and Pipe 3 had relatively low coal flow. Initial results The effect of the EvenFlow system on coal flow distribution was verified by moving all FCEs together across their entire operating range in eight coordinated steps. At each Fig. 8 Baseline distribution for initial tests. step, a coal recovery test was conducted. The results of the tests, shown in Figure 9, illustrate that the EvenFlow coal flow controller has significant effects on the distribution of coal to each pipe. Further, it was demonstrated that each pipe could be affected in both the positive and negative directions. At least a 50% variation in coal flow was measured in each pipe across the FCE output range. In addition, it was noted that many of the coal pipes had several high and low points (peaks and valleys) as the FCE positions were changed. To measure the effect of the EvenFlow controller on air flow distribution, a test was conducted in which only two FCEs were moved by a significant amount. The remaining FCEs were held at a constant position. This test was representative of what would be considered a typical adjustment to the system. Dirty air and coal recovery tests were conducted before and after the change in position. The results of the test are illustrated in Figure 10. For all eight coal pipes, coal flow was found to vary by over 10%, which can be considered a significant change in distribution. Changes in air flow of approximately 16% and 9% were observed on Pipe 6 and Pipe 5, respectively. Less than a 5% change in air flow was observed on the remaining six coal pipes. These results proved that, for typical adjustments (i.e., position changes made for most situations), Fig. 7 Test port locations. Fig. 9 Distribution changes through FCE adjustment range. 4 Babcock & Wilcox Power Generation Group

6 20% low, and Pipes 3 and 6 to be approximately 15% low. The remaining four pipes were within a ±10% distribution. Using the EvenFlow system and the balancing strategy, B&W PGG was able to create a uniform coal flow distribution, nearly entirely within a ±10% deadband. The results of this test are shown in Figure 11. Fig. 10 Change in distribution from typical adjustment test. the EvenFlow controller can significantly affect coal flow distribution with very little impact on air flow distribution. By comparison, testing of orifices installed in burner coal lines showed that a 19% change in coal flow resulted in an 82% change in primary air flow. To further test air flow distribution effects, a gross adjustment test was conducted. In the test, a significant position change was applied to all of the FCEs. Typically, an adjustment of all of the FCEs by a large magnitude would not be necessary. However, this type of movement would establish the maximum effect that the EvenFlow controller would have on primary air. Dirty air and coal recovery tests were conducted prior to and after the adjustment to calculate changes in air flow and coal flow. Even with this extreme movement in the EvenFlow device, the average change in air flow was less than 10% with five of the pipes changing by less than 5%. As expected the coal flow changed considerably more with the average change being greater than 20% and six of eight pipes changing by more than 15%. Both of the air flow tests confirmed that the EvenFlow coal controller had minimal effect on air flow while significantly redistributing the coal flow from the mill. This is a considerable improvement over other devices such as variable orifices. Mill operational data was evaluated through both the typical adjustment test and the gross adjustment test and compared to the same parameters before the installation of the EvenFlow system. No measureable changes were observed in mill pressure drop, mill motor amps or fineness. Balancing Coal Flow Distribution Based on the initial testing, a strategy was developed to use the EvenFlow coal flow controller to balance the coal distribution. The strategy involved taking several iterative steps first by making adjustments to multiple FCEs, then by making fine adjustments to only one FCE until the coal flow distribution was nearly uniform and within a ±10% deadband. A baseline coal recovery test found Pipe 1 to be approximately 55% high in coal flow, Pipe 5 approximately Long-Term Hardware Evaluation In March 2011, over a year after the EvenFlow coal flow controller was installed, a maintenance outage occurred for McIntosh Generating Station Unit 3. During the outage, B&W PGG inspected the EvenFlow cartridge and FCEs. When the system was installed, the FCEs were painted with four layers of paint prior to installation so that the amount of erosion could be evaluated. During the inspection, B&W PGG observed that the top layer of paint was still intact on most of the FCEs and that there were no significant signs of degradation or damage to any of the other EvenFlow system s parts. Therefore, the hardware and materials used were proven to be acceptable and sufficient for the harsh environment within the pulverizer. Conclusion Laboratory testing and computational modeling were used to develop a novel coal flow control device that overcomes the performance problems with burner line-installed devices like variable orifices. The EvenFlow system, installed internal to a pulverizer, was designed to control coal flow to individual coal outlet pipes with negligible effects on primary air flow. The first utility-scale demonstration of the EvenFlow coal flow controller proved that the system can manipulate coal flow distribution from the pulverizer with a minor effect on primary air flow. In addition, the system was used to successfully balance coal flow distribution from the mill in a case where the imbalance was as high as 55%. Hence, the EvenFlow system could be utilized to balance coal distribution to burners and improve boiler combustion, emissions and slagging. Fig. 11 Balancing coal distribution with EvenFlow. Babcock & Wilcox Power Generation Group 5

7 Future Work The EvenFlow coal flow controller was successfully proven as a tool for changing coal distribution to the burners without negatively affecting air flow. It worked well when manually positioned using a PLC-based control system. Future work will focus on integrating the EvenFlow controller with a closed-loop, automatic optimization system. EvenFlow and B&W Roll Wheel are trademarks of Babcock & Wilcox Power Generation Group, Inc. Copyright 2011 by Babcock & Wilcox Power Generation Group, Inc. a Babcock & Wilcox company All rights reserved. No part of this work may be published, translated or reproduced in any form or by any means, or incorporated into any information retrieval system, without the written permission of the copyright holder. Permission requests should be addressed to: Marketing Communications, Babcock & Wilcox Power Generation Group, Inc., P.O. Box 351, Barberton, Ohio, U.S.A Or, contact us from our website at Disclaimer Although the information presented in this work is believed to be reliable, this work is published with the understanding that Babcock & Wilcox Power Generation Group, Inc. (B&W PGG) and the authors are supplying general information and are not attempting to render or provide engineering or professional services. Neither B&W PGG nor any of its employees make any warranty, guarantee, or representation, whether expressed or implied, with respect to the accuracy, completeness or usefulness of any information, product, process or apparatus discussed in this work; and neither B&W PGG nor any of its employees shall be liable for any losses or damages with respect to or resulting from the use of, or the inability to use, any information, product, process or apparatus discussed in this work.

Burner Performance Monitoring Using Advanced Analysis of Optical Signals

Burner Performance Monitoring Using Advanced Analysis of Optical Signals Technical Paper BR-1908 Burner Performance Monitoring Using Advanced Analysis of Optical Signals Authors: T.A. Fuller Babcock & Wilcox Power Generation Group, Inc. Barberton, Ohio, U.S.A. C.S. Daw C.E.A.

More information

Natural Gas Conversions of Existing Coal-Fired Boilers

Natural Gas Conversions of Existing Coal-Fired Boilers White Paper MS-14 Natural Gas Conversions of Existing Coal-Fired s Authors: F.J. Binkiewicz Jr., P.E. R.J. Kleisley B.E. McMahon J.E. Monacelli D.A. Roth D.K. Wong Babcock & Wilcox Power Generation Group,

More information

Assessing the Changes Required by the Industrial Boiler MACT Regulations

Assessing the Changes Required by the Industrial Boiler MACT Regulations Technical Paper MS-17 Assessing the Changes Required by the Industrial Boiler MACT Regulations Authors: A.L. LeClair L.M. McDermitt Babcock & Wilcox Power Generation Group, Inc. Barberton, Ohio, U.S.A

More information

Pulverized Coal Pipe Testing and Balancing

Pulverized Coal Pipe Testing and Balancing Pulverized Coal Pipe Testing and Balancing By Richard F. (Dick) Storm, PE The first step in optimizing combustion system performance is balancing the air and fuel flowing through each of the plant's coal

More information

OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW

OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW ISRAEL ELECTRIC OROT RABIN POWER STATION UNITS 1-4 4 x 350 MW COAL BOILER CONVERSION TO LOW NO X NATURAL GAS AND COAL FIRING BY PRIMARY AND SECONDARY MEASURES INSTALLATION Replacing the Burner Management

More information

Pulverizer Maintenance Services

Pulverizer Maintenance Services MillCare Pulverizer Maintenance Services Two world class mills One universal maintenance program Under the BWCC MillCare program, customers can utilize their own in-house maintenance personnel, choose

More information

Improving Steam Methane Reformer Performance with the ZoloSCAN-SMR

Improving Steam Methane Reformer Performance with the ZoloSCAN-SMR Improving Steam Methane Reformer Performance with the SCAN-SMR The global demand for hydrogen continues to increase as heavier crudes are processed and stricter governmental mandates require reductions

More information

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE The safe, reliable and efficient generation of steam has challenged boiler designers since steam was first harnessed for power.

More information

Low Load Operational Flexibility for Siemens G-class Gas Turbines

Low Load Operational Flexibility for Siemens G-class Gas Turbines Low Load Operational Flexibility for Siemens G-class Gas Turbines Power-Gen International 2008 Orlando, Florida www.siemens.com Power-Gen International Orlando, Florida December 2008 2 Low Load Operational

More information

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Energy Efficient Operations and Maintenance Strategies for Boilers

Energy Efficient Operations and Maintenance Strategies for Boilers Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

Power Plant Operations and Maintenance. Maximize Your Plant s Bottom-Line Results

Power Plant Operations and Maintenance. Maximize Your Plant s Bottom-Line Results Power Plant Operations and Maintenance Maximize Your Plant s Bottom-Line Results Since 1867, The Babcock & Wilcox Company (B&W) has engineered, supplied and constructed advanced steam generation and emissions

More information

Guidelines for Preparing for a Temporary Steam Plant

Guidelines for Preparing for a Temporary Steam Plant Guidelines for Preparing for a Temporary Steam Plant Trailer-Mounted Boilers Skid Mounted Boilers Mobile Boiler Rooms Mobile Feedwater Vans Mobile Steam Plants Emergency Preparedness Plan Table of Contents

More information

Delivering quality power plant products, programs and services

Delivering quality power plant products, programs and services Delivering quality power plant products, programs and services DELIVERING QUALITY W ith thousands of Babcock & Wilcox boilers currently producing steam for countless utilities, various industries such

More information

Baumann 81000 Mikroseal Control Valve

Baumann 81000 Mikroseal Control Valve Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where

More information

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 8, Issue 6 (Sep. - Oct. 2013), PP 25-29 Performance of the Boiler and To Improving the Boiler Efficiency

More information

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves As a rule, control and reduction valves of the globe type have an integrated plug that narrowly

More information

Investigating the Impact of Boiler Aging In Replacement Decisions

Investigating the Impact of Boiler Aging In Replacement Decisions Investigating the Impact of Boiler Aging In Replacement Decisions Siddika Pasi and Michael R. Muller, Rutgers University - Center for Advanced Energy Systems ABSTRACT Traditionally boilers were believed

More information

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler Hitachi Review Vol. 47 (1998), No. 5 183 Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler Kazuhito Sakai Shigeki Morita Tsutomu Yamamoto Toshikazu Tsumura ABSTRACT: The Matsuura

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN Application 1 The first step in selecting an industrial oven is defining the required heat application that your oven will be used for. Heat processing is extensively

More information

Transforming Bottom Ash Into Fly Ash in Coal Fired Power Stations

Transforming Bottom Ash Into Fly Ash in Coal Fired Power Stations 2009 World of Ash (WOCA) Conference - May 4-7, 2009 in Lexington, KY, USA http://www.flyash.info/ S. Kochert, Allen-Sherman-Hoff, et al Transforming Bottom Ash Into Fly Ash in Fired Power Stations MAR

More information

IPB-IB ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS. BECK VIDEO Scan w/ Smartphone

IPB-IB ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS. BECK VIDEO Scan w/ Smartphone IPB-IB R ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS BECK VIDEO Scan w/ Smartphone 1 Increasing Business Pressures Necessitate Boiler Control Improvements Today s industrial

More information

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS CONFERENCE PROCEEDINGS OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS by Edward K. Levy, Nenad Sarunac, and Carlos Romero Energy

More information

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley. Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study

More information

North American Stainless

North American Stainless North American Stainless Flat Products Stainless Steel Grade Sheet 310S (S31008)/ EN 1.4845 Introduction: SS310 is a highly alloyed austenitic stainless steel designed for elevated-temperature service.

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The

More information

Boiler Tune-up Guide

Boiler Tune-up Guide Boiler Tune-up Guide National Emission Standards for Hazardous Air Pollutants for Area Sources: Industrial, Commercial, and Institutional Boilers What is a boiler tune-up? 40 CFR Part 63 Subpart JJJJJJ

More information

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal 19 Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal TAKAO HASHIMOTO *1 KOICHI SAKAMOTO *2 YOSHIKI YAMAGUCHI *3 KOJI OURA *4 KENICHI ARIMA *5 TAKESHI SUZUKI *6 Mitsubishi

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

A descriptive definition of valve actuators

A descriptive definition of valve actuators A descriptive definition of valve actuators Abstract A valve actuator is any device that utilizes a source of power to operate a valve. This source of power can be a human being working a manual gearbox

More information

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers Hitachi Review Vol. 58 (29), No.5 187 Latest Low- Combustion Technology for Pulverized-coal-fired Boilers Kenichi Ochi Kenji Kiyama Hidehisa Yoshizako, Dr. Eng. Hirofumi Okazaki Masayuki Taniguchi, Dr.

More information

Pneumatic control loops save water and energy with fixed-bed filters

Pneumatic control loops save water and energy with fixed-bed filters Pneumatic control loops save water and energy with fixed-bed filters Dr. Wolfgang Rieger, Festo AG & Co. KG, 73734 Esslingen Published in Industrial Valves 2010/2011 Vulkan-Verlag GmbH, Essen/Germany Contact:

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

WARNING CANADIAN D.O.C. WARNING

WARNING CANADIAN D.O.C. WARNING Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison Corp. reserves the right to make changes in the product, the programs, and

More information

Continuous flow direct water heating for potable hot water

Continuous flow direct water heating for potable hot water Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management

More information

Inert Gas Extinguishing System Two Minute Discharge Study. Gene Hill, P.E. Brad Stilwell

Inert Gas Extinguishing System Two Minute Discharge Study. Gene Hill, P.E. Brad Stilwell Inert Gas Extinguishing System Two Minute Discharge Study Gene Hill, P.E. Brad Stilwell Page 2 ABSTRACT Fire testing per UL 2127 and FM 5600 was done with an inert gas extinguishing system utilizing IG-100,

More information

Improving the Thermal Efficiency of Coal-Fired Power Plants: A Data Mining Approach

Improving the Thermal Efficiency of Coal-Fired Power Plants: A Data Mining Approach Paper 1805-2014 Improving the Thermal Efficiency of Coal-Fired Power Plants: A Data Mining Approach Thanrawee Phurithititanapong and Jongsawas Chongwatpol NIDA Business School, National Institute of Development

More information

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless

More information

Texas Commission on Environmental Quality Page 1 Chapter 117 - Control of Air Pollution from Nitrogen Compounds

Texas Commission on Environmental Quality Page 1 Chapter 117 - Control of Air Pollution from Nitrogen Compounds Texas Commission on Environmental Quality Page 1 SUBCHAPTER G: GENERAL MONITORING AND TESTING REQUIREMENTS DIVISION 1: COMPLIANCE STACK TESTING AND REPORT REQUIREMENTS 117.8000, 117.8010 Effective June

More information

Description of Thermal Oxidizers

Description of Thermal Oxidizers Description of Thermal Oxidizers NESTEC, Inc. is a full service equipment supplier specializing in solutions for plant emission problems. The benefit in working with NESTEC, Inc. is we bring 25+ years

More information

Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS

Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS (a) Purpose and Applicability The purpose of this rule is to reduce NOx emissions from natural gas-fired large (commercial)

More information

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code

More information

Completion of SCR System for Ninghai Power Plant Unit 4 in China

Completion of SCR System for Ninghai Power Plant Unit 4 in China Hitachi Review Vol. 57 (2008), No. 6 293 Completion of SCR System for Ninghai Power Plant 4 in China Yoshiro Inatsune Yoshiyuki Takeuchi Masafumi Ishizaki OVERVIEW: The SCR system installed on Ninghai

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Sixth Annual Conference on Carbon Capture & Sequestration

Sixth Annual Conference on Carbon Capture & Sequestration Sixth Annual Conference on Carbon Capture & Sequestration Session Title: Retrofitting of Existing Coal-Fired Plants MHI s Post Combustion CO 2 Recovery Process for Coal Fired Power Stations: Requirement

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013 Sid/Page 1 SESOBS THE SMOKE DENSITY MONITOR - Easy and safe to operate and install - Complete with sealing air fans. - Remote smoke density indication possible. - Designed to meet with the environmental

More information

NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY Proceedings of the 18th Annual North American Waste-to-Energy Conference NAWTEC18 May 11-13, 2010, Orlando, Florida, USA NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED

More information

Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of

More information

Hybrid Power Generations Systems, LLC

Hybrid Power Generations Systems, LLC Coal Integrated Gasification Fuel Cell System Study Pre-Baseline Topical Report April 2003 to July 2003 Gregory Wotzak, Chellappa Balan, Faress Rahman, Nguyen Minh August 2003 Performed under DOE/NETL

More information

New-generation Integrated Monitoring and Control System

New-generation Integrated Monitoring and Control System Hitachi Review Vol. 54 (05), No. 3 145 New-generation Integrated Monitoring and Control System Shigeru Takahashi Satoru Shimizu Takaaki Sekiai OVERVIEW: Hitachi delivered a new-generation integrated monitoring

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

ERCOT Analysis of the Impacts of the Clean Power Plan Final Rule Update

ERCOT Analysis of the Impacts of the Clean Power Plan Final Rule Update ERCOT Analysis of the Impacts of the Clean Power Plan Final Rule Update ERCOT Public October 16, 2015 ERCOT Analysis of the Impacts of the Clean Power Plan Final Rule Update In August 2015, the U.S. Environmental

More information

The Engineer s Guide to Efficiency Requirements for Wood Burning Appliances

The Engineer s Guide to Efficiency Requirements for Wood Burning Appliances For more information about Intertek s testing and certification capabilities, please contact Intertek at: 1-800-WORLDLAB, icenter@intertek.com, or www.intertek.com. BPEE201-11 Introduction The Environmental

More information

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

HOW TO SELECT A LOW VOLUME (L.V ) BOILER HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement

More information

AUTOMATIC CHANGEOVER MANIFOLD Series 915

AUTOMATIC CHANGEOVER MANIFOLD Series 915 AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm

More information

LANDFILL GAS ENCLOSED FLARE SYSTEM

LANDFILL GAS ENCLOSED FLARE SYSTEM LANDFILL GAS ENCLOSED FLARE SYSTEM Part 1. General 1.01 Description A. Information within this specification describes an enclosed flare system designed specifically for the combustion of landfill gas.

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600

More information

MC (Multi-Circulation) f o r S A G D a n d I n d u s t r i a l A p p l i c a t i o n s

MC (Multi-Circulation) f o r S A G D a n d I n d u s t r i a l A p p l i c a t i o n s MC (Multi-Circulation) f o r S A G D a n d I n d u s t r i a l A p p l i c a t i o n s Babcock & Wilcox Canada TSSG TM - SAGD-MC a n d I n d u s t r i a l A p p l i c a t i o n s w i t h M u l t i - C

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing DuPont FM-200 agent,

More information

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural

More information

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN. www.yokogawa.

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN. www.yokogawa. Boiler Control Boiler Control Instruments and for Automatic Boiler Control LF3BUSS02-00EN www.yokogawa.com Best for Automatic Boiler C Sensors and controllers for the efficiency and environmental performance

More information

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012 University of Maryland College Park District Energy System IDEA Campus Energy Conference February 9, 2012 UMCP District Energy System The University of Maryland district energy system consists of a well

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible

More information

heat treatment equipment & accessories

heat treatment equipment & accessories heat treatment equipment & accessories INDUSTRIAL FURNACES Dear Customer, ElectroHeat Sweden AB is an innovative company based in Gothenburg, Sweden, and has been operating since 1975. We manufacture industrial

More information

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness

More information

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A 2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship

More information

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems DFC Technology Used as Electrochemical Membrane for CO 2 Purification and Capture during Power Generation FCE s Direct

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES by Kazuhiro Takeda Research Manager, Research and Development Center and Kengo Hirano Instrument and Control Engineer,

More information

Airplane wing test stand for simulating the airstream. Airbus Deutschland GmbH

Airplane wing test stand for simulating the airstream. Airbus Deutschland GmbH Airplane wing test stand for simulating the airstream Airbus Deutschland GmbH 2 1 Airplane wing test stand for simulating the airstream Hänchen ist standard In test stands at Airbus in Bremen, Hänchen

More information

Heat-Pipe Heat Exchanger

Heat-Pipe Heat Exchanger Heat-Pipe Heat Exchanger Heat Pipe Heat Exchanger For air-air 1 Heat Pipe Heat Exchanger Heat exchanger, which transfers the heat from one medium to another, is the most common thermal equipment in various

More information

Techniques to Improve Measurement Accuracy in Power Plant Reported Emissions

Techniques to Improve Measurement Accuracy in Power Plant Reported Emissions Techniques to Improve Measurement Accuracy in Power Plant Reported Emissions Carlos E. Romero Nenad Sarunac Senior Research Engineer Principal Research Engineer Energy Research Center Energy Research Center

More information

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology Combustion Technology INNOVATIVE SOLUTIONS FOR COMBUSTION AND EMISSIONS CHALLENGES Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems Callidus Technologies by Honeywell - Experie

More information

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency International Journal of Advanced Mechanical Engineering. ISSN 2250-3234 Volume 4, Number 1 (2014), pp. 1-8 Research India Publications http://www.ripublication.com/ijame.htm A Review on Power Generation

More information

(205) 670-5088 (205) 670-5863

(205) 670-5088 (205) 670-5863 Ruth Ann Yongue Roxann Laird Senior Engineer Assistant Project Director rayongue@southernco.com rfleonar@southernco.com (205) 670-5088 (205) 670-5863 Southern Company Services Power Systems Development

More information

SAM HOUSTON STATE UNIVERSITY

SAM HOUSTON STATE UNIVERSITY PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

NSW Air Quality Monitoring Network: Quality Assurance Procedures

NSW Air Quality Monitoring Network: Quality Assurance Procedures NSW Air Quality Monitoring Network: Quality Assurance Procedures Copyright State of NSW and Office of Environment and Heritage With the exception of photographs, the State of NSW and Office of Environment

More information

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management Harry Hsiao, Moxa Product Manager (harry.hsiao@moxa.com) Traditional SCADA (Supervisory Control and Data Acquisition) systems have been an important part of automation control systems for many years, and

More information

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers 192 Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers Masayuki Hirano Yasuyoshi Kato

More information

Employing a Data Acquisition Handling System (DAHS) for New Source Performance Standards (NSPS) Ja Rule Reporting of Petroleum Refinery Emissions

Employing a Data Acquisition Handling System (DAHS) for New Source Performance Standards (NSPS) Ja Rule Reporting of Petroleum Refinery Emissions Technical Paper BR-1923 Employing a Data Acquisition Handling System (DAHS) for New Source Performance Standards (NSPS) Ja Rule Reporting of Petroleum Refinery Emissions Authors: D.C. Pretty Babcock &

More information

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control

More information

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

Streaming Potential System (SPT1000, SPD1000)

Streaming Potential System (SPT1000, SPD1000) Streaming Potential System (SPT1000, SPD1000) User's Manual Sentrol Systems, Inc. 3949 Cotswold Dr. SW, Lilburn, GA 30047-2371 Tel: 770-564-1541, Fax: 770-564-8605 www.sentrolsystems.com Since the streaming

More information