TRANSDUCER TEST. Example Owner 10/13/2014. Example Plant WATTHOUR METERS WATTHOUR METERS, TRANSDUCERS GENERAL OWNER PAGE DATE AMBIENT TEMP.
|
|
- Piers Boone
- 7 years ago
- Views:
Transcription
1 TRANSDUCER TEST 1, TRANSDUCERS NAMEPLATE DATA CURRENT FREQUENCY ELEMENTS CALIBN ADJUSTMENT ACCURACY OUTPUT TEST RESULTS MILLIAMP OUTPUT INPUT ANGLE DEGREES AS FOUND AS SPECIFIED AS LEFT 61550, REVISED 4/22/2009
2 WATTHOUR METER TEST 2, TRANSDUCERS kwhr METER DATA PKh Kh TA STATORS CAT. NO./STYLE NO. INSTRUCTION BOOKLET kwhr REGISTER DATA SCALE kw REGISTER INTERVAL MIN. DIRECT RDG. FOR Kh CURRENT TRANSFORMER DATA :5 ACCURACY STYLE BURDEN TRANSFORMER DATA :1 ACCURACY VOLTAMPERE RATING VA POLARITY AS FOUND READINGS kwhr AS FOUND TESTS ELEMENT BALANCE: 50 FP, REVOLUTIONS ACTUAL CALCULATED STAND. CORR. METER AS LEFT TESTS ELEMENT BALANCE: 50 FP, CALCULATED REVOLUTIONS STAND. CORR. METER ACTUAL INDICATOR TEST VOLTS & 100 P.F. FOR MINUTES = kw PULSE INITIATOR TEST SPECIFIED TEST RESULTS: AS LEFT READINGS kwhr WIRING CORRECT PER MFR. DIAGRAM NO. OPERATING 3 PH 3W 3 PH 4W 1 PH kwhr S/N CALIBN 61101, REVISED 4/22/2009
3 KILOWATT-HOUR METER SERVICE RECORD 3, TRANSDUCERS REMOVED SERIAL NUMBER / READING ON REMOVED ON REMOVED REINSTALLED READING ON REINSTALLED 61000, REVISED 4/22/2009
4 MULTIFUNCTION METERING MODULE 4, TRANSDUCERS NAMEPLATE DATA MODEL STYLE / SERIES NO. CONTROL INSTRUCTION MANUAL NO. INSTRUMENT TRANSFORMER DATA TRANSFORMER: PRIMARY V SECONDARY V VTR = CURRENT TRANSFORMER: PRIMARY CURRENT A SECONDARY CURRENT A CTR = READINGS PT SECONDARY (volts) VTR SYSTEM (volts) MULTIFUNCTION METER READING PERCENT ERROR A - N B - N C - N A - B A - C B - C CURRENT READINGS CT SECONDARY CURRENT (amps) CTR SYSTEM CURRENT (amps) MULTIFUNCTION METER READING PERCENT ERROR A B C 61600, REVISED 4/22/2009
5 WATTHOUR METER TEST 5, TRANSDUCERS kwhr METER DATA PKh Kh TA STATORS CAT. NO./STYLE NO. INSTRUCTION BOOKLET kwhr REGISTER DATA SCALE kw REGISTER INTERVAL MIN. DIRECT RDG. FOR Kh CURRENT TRANSFORMER DATA :5 ACCURACY STYLE BURDEN TRANSFORMER DATA :1 ACCURACY VOLTAMPERE RATING VA POLARITY AS FOUND READINGS kwhr AS FOUND TESTS ELEMENT BALANCE: 50 FP, REVOLUTIONS ACTUAL STAND. CORR. METER AS LEFT TESTS ELEMENT BALANCE: 50 FP, REVOLUTIONS STAND. CORR. METER ACTUAL INDICATOR TEST VOLTS & 100 P.F. FOR MINUTES = kw PULSE INITIATOR TEST SPECIFIED TEST RESULTS: AS LEFT READINGS kwhr WIRING CORRECT PER MFR. DIAGRAM NO. OPERATING 3 PH 3W 3 PH 4W 1 PH kwhr S/N CALIBN 61100, REVISED 4/22/2009
6 VAR TRANSDUCER TEST 6, TRANSDUCERS NAMEPLATE DATA CURRENT FREQUENCY ELEMENTS CALIBN ADJUSTMENT ACCURACY OUTPUT TEST RESULTS MILLIAMP OUTPUT INPUT ANGLE VAR INPUT AS FOUND AS SPECIFIED AS LEFT ANGLE MULTIPLIER (TANGENT) ANGLE 0 DEG 30 DEG MULTIPLIER ANGLE MULTIPLIER ANGLE MULTIPLIER 45 DEG -30 DEG DEG -90 DEG DEG , REVISED 4/22/2009
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationPower Transducer User s Guide
Power Transducer User s Guide Volume 1 Power Transducer User's Guide Volume 1 Applying Power Transducers Volume 1 Page I. Why Monitor Power?... 1 II. Beginning Definitions... 3 III. Basic Concepts of AC
More informationDigital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
More informationVOLTAGE REGULATOR AND PARALLEL OPERATION
VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by
More informationTRANSFORMER LOSS COMPENSATION FOR METERMEN PRESENTED BY: MICHAEL K. BEARDEN
TRANSFORMER LOSS COMPENSATION FOR METERMEN PRESENTED BY: MICHAEL K. BEARDEN WHAT are transformer losses? TRANSFORMER LOSS COMPENSATION THE WHAT, WHEN, WHO, WHERE AND HOW Transformer losses can be viewed
More informationCurrent Transformers
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only
ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category
More informationSmartBlock Power and Energy Monitor With Rogowski Coil (di/dt) Support HE579ACM302
MA0961-02 25 ovember 2013 PAGE 1 SmartBlock Power and Energy Monitor With Rogowski oil (di/dt) Support The SmartBlock AM302 is a Power and Energy Monitor designed to interface with Rogowski oil and OT
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationTESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering
TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering Introduction This application note will assist the user to set up 3-phase metering to monitor Watt, VAR and VA power
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationSECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
More informationSelecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
More informationCURRENT TRANSFORMERS INSTALLATION GUIDE
CURRENT TRANSFORMERS INSTALLATION GUIDE Information contained within this document is subject to change without notice and does not represent a commitment on the part of PRI Ltd or its agents. E&OE. Copyright
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationThree phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
More informationTransformer circuit calculations
Transformer circuit calculations This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,
More informationMeasurement of Power in single and 3-Phase Circuits. by : N.K.Bhati
Measurement of Power in single and 3-Phase Circuits by : N.K.Bhati A specifically designed programme for Da Afghanistan Breshna Sherkat (DABS) Afghanistan 1 Areas Covered Under this Module 1. Power in
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationMultilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.
GE Grid Solutions Multilin EPM 6000 High Accuracy Power & Energy Measurement The Multilin EPM 6000 is one of the industry s highest performance revenue grade panel meters with superior cost to performance
More informationPROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B
WHITE PAPER PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS BULLETIN 1497, 1497A, AND 1497B CONTROL CIRCUIT TRANSFORMERS The proper selection of the control circuit transformers is important for suitable
More informationR448 & R448 V50 A.V.R.
Armature + 6- This manual is to be given to the end user F1 ST5 Field Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency ST10 50Hz 60Hz
More informationCurrent Transformers Ratio / Polarity / Types
CT1 Current Ratio / Polarity / Types Application Current (CT s) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. CT s
More informationR438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V 110 220
Armature 6- This manual is to be given to the end user 1 T5 Field Slow fuse 250V 8 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 220 T3 quency T10 50Hz 60Hz LAM 13 %
More informationEnergy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
More informationUnderstanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
More informationEMC6D103S. Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES ORDER NUMBERS: Data Brief
EMC6D103S Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES Data Brief 3.3 Volt Operation (5 Volt Tolerant Input Buffers) SMBus 2.0 Compliant Interface
More information3-Phase AC Calculations Revisited
AN110 Dataforth Corporation Page 1 of 6 DID YOU KNOW? Nikola Tesla (1856-1943) came to the United States in 1884 from Yugosiavia. He arrived during the battle of the currents between Thomas Edison, who
More informationwww.electroind.com. March 15th 2005 EI Solutions - Submetering 1
. March 15th 2005 EI Solutions - Submetering 1 What is Submetering? Electric Service Master Meter Utility Owned POCC Utility Billing Point Sub Meter Electric Distribution Sub Meter Sub Meter Sub Meter
More informationMetering Devices IQ Analyzer 6400/6600 Series
Metering Devices IQ Analyzer 6400/6600 Series Technical Data Supersedes TD.17.02A.T.E pages 1-8 dated May 2000 Description Page General Description............................................. 2 Applications....................................................
More informationApplication for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (See ARSD chapter 20:10:36 for the requirements for a Tier 2, Tier 3, or Tier 4 Interconnection.) Applicant/Interconnection
More informationCat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM
Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More information0.84" x 2.00" Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.
SPLIT CORE CURRENT MODEL 1SP 0.84" x 2.00" PAGE No 3-2 REV 18DEC00 UL 1015 LEAD WIRE, STANDARD LENGTH IS 36 E DIMENSIONS A = 0.84 MIN B = 2.00 MIN C = 3.31 MAX D = 3.09 MAX E = 0.61 MAX F = 0 MAX F C B
More informationCT Analyzer: Coming to the Rescue. Introduction. Equivalent Circuit. Construction. Classification of a CT. Tony Porrelli, OMICRON, UK
Presentation 09.1 CT Analyzer: Coming to the Rescue Tony Porrelli, OMICRON, UK Introduction The Current Transformer (CT) may exist for many applications but for this paper we can think about them being
More informationApplications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
More informationDual AC Power Monitor
User Manual for the HE200ACM500 Dual AC Power Monitor Page 1 of 28 PAGE 2 Page 2 of 28 PAGE 3 PREFACE This manual explains how to use the Dual AC Power Monitor. Copyright (C) 2008 Horner APG, LLC., 59
More informationPolyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
More informationEffective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
More informationUSE OF A SINGLE ELEMENT WATTMETER OR WATT TRANSDUCER ON A BALANCED THREE-PHASE THREE-WIRE LOAD WILL NOT WORK. HERE'S WHY.
USE OF A SINGLE ELEMENT WATTMETER OR WATT TRANSDUCER ON A BALANCED THREE-PHASE THREE-WIRE LOAD WILL NOT WORK. HERE'S WHY. INTRODUCTION Frequently customers wish to save money by monitoring a three-phase,
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationHJA-626, HJA-636, HJA-646 ISSUE 4.0. 2001 Universal Protection Corporation A Division of: H.J. Arnett Industries Fourth Printing, October 2007
CHECK METER HJA-626, HJA-636, HJA-646 ISSUE 4.0 2001 Universal Protection Corporation A Division of: H.J. Arnett Industries Fourth Printing, October 2007 Universal Protection Corp./ H.J Arnett Industries
More information93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal
Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationLOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS
Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON
More informationDigital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
More informationEARTH LEAKAGE PROTECTION: CONTENTS
EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E
More informationTurbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
More informationPhysical Address: City: State: Zip Code:
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (For Small Generator Facilities with Electric Nameplate Capacities of 10 MW and less) Applicant Contact
More informationCurrent Transformers. Bonneville Power Administration. Steve Laslo For the Hands On Relay School (3-12) Revision 1.1. February 21, 2012 1
Current Transformers Bonneville Power Administration Steve Laslo For the Hands On Relay School (3-12) Revision 1.1 February 21, 2012 1 Basic Theory: CT as a Voltage Transformer February 21, 2012 2 CT as
More informationInstruction Manual. EPM 6010 Multi-function Power Metering System. Chapter 1: *1601-0215-A1* GE Energy ISO 9001 LISTED
GE Energy EPM 6010 Multi-function Power Metering System Chapter 1: Instruction Manual Software Revision: 1.17 Manual P/N: 1601-0038-A1 Manual Order Code: GEK-113637 Copyright 2012 GE Digital Energy GE
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More information11. MEASUREMENT OF POWER CONSUMPTION OF THE NONBALANCED THREE-PHASE LOAD
. MEASEMENT OF OE CONSMTION OF THE NONBALANCED THEE-HASE LOAD Task of the measurement. Measure the active power and the reactive power of the nonsymmetrical -phase load in Y-connection. Do not connect
More informationDIGITAL SWITCHBOARD METERS
DIITAL SWITCHBOARD METER MODELS 2491, 2492, FEATURES The Model 2491 (Single function), Model 2492 (Dual function), and Model (Triple Function) Digital Switchboard Meters were developed to provide customers
More informationUsing Current Transformers with the 78M661x
A Maxim Integrated Products Brand Using Current Transformers with the 78M661x APPLICATION NOTE AN_661x_021 April 2010 Introduction This application note describes using current transformers (CT) with the
More informationInstrument Transformer Wiring Troubleshooting Guide Three Phase Meters Revision 0, Initial Issue, April 26, 1993
R Instrument Transformer Wiring Troubleshooting Guide Three Phase Meters Revision 0, Initial Issue, April 26, 1993 CONTENTS I. How to Use This Guide II. Common Problems for 3-Wire and 4-Wire Systems III.
More informationPASNY DELIVERY SERVICE. Applicability: To PASNY Customers who are not served under Rate II, Rate III, or Rate IV.
PSC NO: 12 Electricity Leaf: 4 Rate I Applicability: To PASNY Customers who are not served under Rate II, Rate III, or Rate IV. Applicable to demand-metered service, street lighting in The City of New
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationOperation, Maintenance, and Field Test Procedures for Protective Relays and Associated Circuits
Facilities Instructions, Standards, and Techniques Volume 3-8 Operation, Maintenance, and Field Test Procedures for Protective Relays and Associated Circuits Previously Titled: Field Testing Procedures
More informationINDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2
INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2 By: R.C. Zowarka T.J. Hotz J.R. Uglum H.E. Jordan 13th Electromagnetic Launch Technology Symposium, Potsdam (Berlin), Germany,
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design
Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,
More informationmaxon sensor maxon sensor
Sensor Spindle drive Gearhead E Motor (BLD Motor) D Motor X Drives (configurable) Motor control obust encoders, D tachometers, and resolvers with high accuracy and high signal resolution. Due to resonance,
More informationTool Turrets and Tool Discs
Our other products Automatic Tool Changer Chucking Cylinders Tool Discs Indexing Tables Tool Turrets and Tool Discs Pragati Automation Pvt. Ltd. 1, IV Phase, 11th Cross, Peenya Industrial Area Bangalore
More informationPacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP
PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection
More informationPower Electronics Testings
Power Electronics Testings PV Inverter Test Solution www.chromaate.com Turnkey Test & Automation Solution Provider w w w.chromaate.com A PV system is an energy system which directly converts energy from
More informationSchedule GS-3 LARGE GENERAL SERVICE SECONDARY VOLTAGE I. APPLICABILITY AND AVAILABILITY
I. APPLICABILITY AND AVAILABILITY A. Except as modified herein, this schedule is applicable only to a non-residential secondary voltage Customer (as defined in Paragraph XII.) who (1) elects (a) to receive
More informationUnit 33 Three-Phase Motors
Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation
More informationBill Younger, Manager Business Energy Management Puget Sound Energy Bellevue, Washington
Bill Younger, Manager Business Energy Management Puget Sound Energy Bellevue, Washington Multifunction Portals for Commercial and Industrial Customers Customer Needs Energy Information Pipeline Customer
More informationNECOCAR. International CATIA Project
NECOCAR International CATIA Project 2008 GOAL The goal of this project is to design an electrocar for the Japanese public. Cute Comfortable Modern Ecological ORGANIZATION Russe-Français CATIA V5 R18 Sharing
More informationFundamentals of Electrical Power Measurement
Fundamentals of Electrical Power Measurement Barry Bolling Application Engineer Yokogawa Corporation of America Credits: Bill Gatheridge Presentation: IEEE / UTC Aerospace 2012 Yokogawa Corporation of
More informationINTEGRATED CIRCUITS. For a complete data sheet, please also download:
INTEGRATED CIRCUITS DATA SEET For a complete data sheet, please also download: The IC6 74C/CT/CU/CMOS Logic Family Specifications The IC6 74C/CT/CU/CMOS Logic Package Information The IC6 74C/CT/CU/CMOS
More informationUser s Manual. Multifunction Transducer MT440
User s Manual GB Multifunction Transducer MT440 Table of contents Table of Contents 1. SECURITY ADVICE AND WARNINGS 1 1.1 Welcome ---------------------------------------------------------------------------------------------
More informationPow-R-Con Multi Function Control
37264 Pow-R-Con Multi Function Control Product Specification Product Specification 37264 Product Information DYNA Power Controls Pow-R-Con TM GENERAL The Barber-Colman Pow-R-Con TM represents an integrated
More informationDale Pennington, Managing Director, Utiliworks Consulting LLC, New York, USA
Dale Pennington, Managing Director, Utiliworks Consulting LLC, New York, USA Meter Data from Cradle to Grave, do you know where your Data is? Getting Started Create your project team such that all critical
More informationTURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
More informationFlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3
FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 Instruction Manual D2-3405-2 The information in this manual is subject to change without notice. Throughout this manual, the following
More informationAC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.
AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing This document was prepared by Advanced Energy. December 12 th, 2014 Introduction In June of this year, AC Kinetics contacted
More informationEnergy Display Meter User Guide Engage, educate and inspire smart energy usage
Energy Display Meter User Guide Engage, educate and inspire smart energy usage Introducing your new Energy Display Meter This user guide is designed to provide you with all you need to know about the new
More informationLEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems
LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the
More informationBasic Nameplate Information
Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address
More informationShark 200-S. Installation & Operation Manual Revision 1.02. Electronic Submeter with WIFI Ethernet Capability and Datalogging
Shark 200-S Electronic Submeter with WIFI Ethernet Capability and Datalogging Installation & Operation Manual Revision 1.02 June 5, 2009 Doc #: E149721 V1.02 e Electro Industries/GaugeTech 1800 Shames
More informationSection III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS
PART III TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS I. GENERAL The objective of this specification is to describe a system which uses solar energy to produce electricity. For each site (lot) one
More informationTest & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationJEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual
JEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual Revised on February 15, 2012 Table of Contents I. Introduction... 2 II. Choosing the Proper Transformer... 2 III. Rapid Selector Charts...
More informationProduced by Alan Ward
Produced by Alan Ward Contents Approved Billing Meters 5 Electricity Act 1989 Measuring Instruments Directive Code of Practice 5 (CoP5) Renewable Obligations Certificate (ROC) Metering Elements of Sub
More informationINDUCTION REGULATOR. Objective:
INDUCTION REGULATOR Objective: Using a wound rotor induction motor an Induction Regulator, study the effect of rotor position on the output voltage of the regulator. Also study its behaviour under load
More informationOne Meter Works for Both Energy Saving and Power Quality Surveillance
Multi-Function Meter Eco-POWER METER W9M SERIES Conforming to ow Voltage and EMC Directives One Meter Works for Both Energy Saving and Quality Surveillance High accuracy: 0.2 %* Harmonic measurement* Simple
More informationNemo 96HD/HD+ MODBUS
18/12/12 Pagina 1 di 28 MULTIFUNCTION FIRMWARE 2.30 Nemo 96HD/HD+ MODBUS COMMUNICATION PROTOCOL CONTENTS 1.0 ABSTRACT 2.0 DATA MESSAGE DESCRIPTION 2.1 Parameters description 2.2 Data format 2.3 Description
More informationCONSULTANT REPORT. Behavior of Two Capstone 30kW Microturbines Operating in Parallel with Impedance Between Them CALIFORNIA ENERGY COMMISSION
CALIFORNIA ENERGY COMMISSION Behavior of Two Capstone 3kW Microturbines Operating in Parallel with Impedance Between Them CONSULTANT REPORT MARCH 2 CEC-2-2 Arnold Schwarzenegger, Governor CALIFORNIA ENERGY
More informationParalleling and Protection Unit Type PPU multi-line 2 4189340230E
User s manual Paralleling and Protection Unit Type PPU multi-line 2 Software ver. 1.4X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
More informationPOSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)
IM213P-MC 0312 0003 POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE) INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationSOLAR300N Rel. 1.03 21/01/10
Photovoltaic installation certifier + professional network analyzer Pag 1 of 5 1. SOLAR300N MAIN FEATURES SOLAR300N performs all tests on PV plants by using of SOLAR-02 remote unit which, after a preliminary
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationSchedule GS-2 INTERMEDIATE GENERAL SERVICE
I. APPLICABILITY AND AVAILABILITY A. Except as modified herein, this schedule is applicable only to a non-residential Customer (1) who elects (a) to receive Electricity Supply Service and Electric Delivery
More informationDiode Applications. by Kenneth A. Kuhn Sept. 1, 2008. This note illustrates some common applications of diodes.
by Kenneth A. Kuhn Sept. 1, 2008 This note illustrates some common applications of diodes. Power supply applications A common application for diodes is converting AC to DC. Although half-wave rectification
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More information