Model S800 Machine Mounted Methane Monitoring System

Size: px
Start display at page:

Download "Model S800 Machine Mounted Methane Monitoring System"

Transcription

1 Machine Mounted Methane Monitoring System The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General Monitors. Instruction Manual 1006 General Monitors reserves the right to change published specifications and designs without prior notice. Part No. Revision MANS800 MANS800 D/12-07

2 Table of Contents Figures...iii Warranty Statement.1 Warnings 1 System Integrity Verification Introduction Notice General Features and Benefits System Specifications Notice System Specifications Mechanical Specifications Electrical Specifications Environmental Specifications System Description Installation Notice Upon Receipt of Equipment Power Supply Installation S800 Installation S800 Terminal Connections Installation Check-Out Sensor Locations Sensor Poisons Operation Notice General Maintenance Electrical Inputs/Outputs Alarm Conditions Latch/Non-Latch Alarm LED Test Feature Ramp Test Feature Fault Diagnostics User Interfaces Notice...15 i

3 5.2 Types of Interfaces Auto-Calibration Mode Sensor Assembly/Accessories Notice Sensor Housing Splash Guard Dust Guard Assembly Calibration Equipment Technical Information Spare Parts S800 Tool List Electronic Module Module Base Assembly Power Supply Assembly Detector Housing Assembly MSHA Installation Letter ii

4 Figures Figure 1: Wire Strip Length... 8 Figure 2: Color Coded Wiring Connections Figure 3: User Interfaces/Displays Figure 4: Entering Auto-Calibration Sepuence Figure 5: AC Auto-Calibration Display Figure 6: CP Auto-Calibration Display Figure 7: CC Auto-Calibration Display Figure 8: Sensor Housing Drawing Figure 9: Splash Guard, Picture Figure 10: Dust Guard Figure 11: Dust Guard Kit Figure 12: Electronic Module Figure 13: Module Base Assembly Figure 14: PowerSupply Assembly Figure 15: Detector Housing Assembly iii

5 Warranty Statement United Central Industrial Supply, exclusive Mining distributor for General Monitors, Warrants the Model S800 to be free from defects in workmanship or material under normal use and service within one (1) year from the date of shipment. General Monitors will repair or replace without charge any such defective equipment to be found defective during the warranty period. Full determination of the nature of, and Responsibility for, defective or damaged equipment will be made by General Monitors personnel. Defective or damaged equipment must be shipped prepaid to General Monitors plant or the representative from which shipment was made. In all cases this warranty is limited to the cost of the equipment supplied by General Monitors. The customer will assume all liability for the misuse of this equipment by its employees or other Personnel. All warranties are contingent upon proper use in the application for which the product was intended and do not cover products which have been modified or repaired without General Monitors approval or which have been subjected to neglect, accident, improper installation or application, or on which the original identification marks have been removed or altered. Except for the express warranty stated above, General Monitors disclaims all warranties with regard to the products sold, including all implied warranties of merchantability and fitness and the express warranties stated herein are in lieu of all obligations or liabilities on the part of General Monitors for damages including, but not limited to, consequential damages arising out of/or in connection with use or performance of the product. Warnings Combustible & flammable gases and vapors are very dangerous. Extreme caution should be used when combustible & flammable gases and vapors are present. Where applicable, adhere to Mine Safety and Health Administration guidelines for service and installation. Only catalytic bead sensors designed by General Monitors will work with the Model S800. Any attempt to use a sensor that has not been designed by General Monitors will void the warranty. SAFETY WARNING: Installation and maintenance must be carried out by suitably skilled and competent personnel only. 1

6 System Integrity Verification General Monitors mission is to benefit society by providing solutions through industryleading safety products, services and systems that save lives and protect capital resources from the dangers of hazardous flames, gases and vapors. The safety products you have purchased should be handled carefully and installed, calibrated, and maintained in accordance with the respective product instruction manual. Remember, these products are for your safety. To ensure operation at optimum performance, General Monitors recommends that certain maintenance items are performed. Commissioning Safety Systems Before power up, verify wiring, terminal connections and stability of mounting for all integral safety equipment including, but not limited to: Power supplies Control modules Field detection devices Signaling / output devices Accessories connected to field and signaling devices After the initial application of power (and any factory specified warm-up period) to the safety system, verify that all signal outputs, to and from devices and modules, are within the manufacturers specifications. Initial calibration / calibration checking / testing should be performed per the manufacturers recommendations and instructions. Proper system operation should be verified by performing a full, functional test of all component devices of the safety system, ensuring that the proper levels of alarming occur. Fault/Malfunction circuit operation should be verified. Periodic Testing/Calibration of Field Devices Periodic testing/calibrating should be performed per the manufacturers recommendations and instructions. Testing/Calibrating procedures should include, but not be limited to: Verify zero reading Apply a known concentration of gas, or a simulated test device provided by the manufacturer Verify integrity of all optical surfaces and devices When testing produces results outside of the manufacturers specifications, re-calibration or repair/replacement of the suspect device(s) should be performed as necessary. Calibration 2

7 intervals should be independently established through a documented procedure, including a calibration log maintained by plant personnel, or third party testing services. 1.0 Introduction 1.1 Notice This Chapter provides a brief description of the Model S800 and its features & benefits. More detailed information on the features and benefits listed in section 1.2 will be presented in later chapters. The S800 is easy to install and operate; however, this manual should be read in full, and the information contained herein understood before attempting to install or operate the system. 1.2 General The General Monitors Model S800 Smart Methane Monitoring System is a single channel monitoring system designed specifically for the mining industry for installation on longwalls, continuous miners and other face cutting equipment. It is supplied through our exclusive mining distributor, United Central Industrial Supply (UCISC). UCISC should be consulted if service beyond the scope of this manual becomes necessary. The Model S800 is based upon General Monitors latest sensing technology and consist of an S800 Power Supply Module, a remote mounted catalytic bead sensor in its own explosive-proof housing, and a large LED display (approximately two inches high available in yellow or red) incorporated into an explosion proof (XP) housing. The basic system is a single channel unit; however, two channel operation may be achieved by adding an additional display unit and an additional sensing unit. 1.3 Features and Benefits Single Point, Auto-Calibration: the unit s display indicates simple automated calibration prompts to the operator with no adjustments of zero and span required. Microprocessor Based Electronics: Monitors fault conditions and sensor inputs and provides outputs in the form of display codes and relay contacts. Power On Self Test (POST): this is a test that is performed by the microprocessor each time power is applied to the S800. LED Test: tests the integrity of each LED and each segment of the digital display. Ramp Test: tests the functionality of the instrument through the microprocessor ramping up in the signal from the present gas level to full scale and back. The Model S800 Smart Methane Monitoring System is approved for use by The Mine Safety and Health Administration (MSHA). 3

8 2.0 System Specifications 2.1 Notice This Chapter provides detailed specifications for the model S800 Machine Mounted Methane Monitoring System. The system mechanical, electrical and environmental specifications present the Model S800 in Technical terms. The unit description is provided for insertion into other written specifications by architects and engineers. 2.2 System Specifications Application: combustible & flammable gas and vapor detection. Sensor Type: General Monitors low temperature, catalytic bead, limited diffusion sensor. Measuring Range: 0 to 5% Methane gas by volume or 0 to 100%LEL. Accuracy: ±3% of full scale for gas concentrations up to and including 50% of full scale. For gas concentrations greater than 50%, the accuracy of the systems will be ±5% of the full scale gas concentration. Zero Drift: less than 5% of span per year. Response Time: Time to 50% of full scale < 10 seconds with 100%LEL concentration of Methane applied. Time to 90% of full scale < 30 seconds with 100% LEL Concentration of Methane Applied. User Protection: The Model S800 is MSHA certified (Cert# 32A-23/MS-0), Commonwealth of Pennsylvania approved (Cert# BFE ) and warranted for one year on parts and labor. AWG Feet Meters Mechanical Specifications Power Supply: Weight: Length: Height: Width: 5 lbs 2 oz (2.3 Kg) 8 inches (20.3 cm) 3.5 inches (8.9 cm) 5 inches (12.7 cm) 4

9 Sensor Housing with Sensor: Weight: Depth: Height: Width: 6 lbs 7 oz (2.9 Kg) 8.5 inches (21.6 cm) 2.2 inches (5.6 cm) 3.2 inches (8.1 cm) Electronics with XP Housing: Weight: Depth: Height: Width: 8 lbs 10 oz (3.9 Kg) 5.6 inches (14.2 cm) 4.6 inches (11.7 cm) 8 inches (20.3 cm) 2.4 Electrical Specifications Input Power Requirements: To Power Supply-120Vac 150mA. To Instrument-13 to 17 Vdc (15 500mA nominal). Electrical Classifications: the sensor is rated for use in Class I, Division 1, Groups B, C & D. The model S800 is designed for use in hazardous environments. Machine Cut-off Relay Output: 120Vac SPDT, 600Vac SPDT. Remote Output: 12Vdc SPDT, 120Vac SPDT. Cable Parameters: Recommended 3 wire shielded, maximum cable lengths allowable between module and sensor with one way resistance of 10Ohms per sensor lead (20 Ohms 4.5Vdc nominal is 7600 feet (2320 Meters) using 14 AWG. 2.5 Environmental Specifications Operating Temperature Range: Sensor: -67F to +200F (-55C to +93C) S800: -40F to +140F (-40C to +60C) Operating Humidity Range: Vibration Specifications: 0 95% relative humidity (non-condensing) as per Mine Safety and Health Administration (MSHA). Weather Proof Protection: Conforming to weather proofing per NEMA 4X. Radio Frequency Interference Susceptibility: Conforms to levels defined by IEC Severity Level 3. 5

10 2.6 System Description The monitor and sensor shall be MSHA approved and be capable of monitoring 0 to 5% Methane gas by volume or 0 to 100% LEL concentration. The monitor shall have an interface panel, providing magnetic switches for the following indications: 2-discrete alarm threshold level indicators, a fault or malfunction indicator, a calibration mode indicator and a 2-digit display. All alarm parameters and user options shall be configurable by qualified personnel. A power on self-test (POST) shall automatically be performed each time the monitor powers up. A functional ramp test and LED test shall be switch capable without interrupting normal on-line services. The monitor will generate display codes associated with fault conditions whenever a fault or malfunction occurs. A magnetic switch shall provide the operator front panel access to a calibration mode. The monitor, with sensor, shall be capable of calibration with the following display prompts during the calibration routine: AC = Calibration routine Activated CP = Calibration in Progress CC = Calibration Complete 6

11 3.0 Installation 3.1 Notice This Chapter outlines what steps to take when the Model S800 is received, the terminal connections & designations, sensor locations and what to be aware of when applying power. 3.2 Upon Receipt of Equipment All equipment shipped by General Monitors is packaged in shock absorbing containers which Provide considerable protection against physical damage. The contents of the package should be carefully removed and checked. If any damage has occurred in shipping, or if there is a discrepancy in the order, notify United Central Industrial Supply immediately. Please specify the affected part and serial number if applicable. Each Model S800 is completely checked out at the factory; however, a complete check-out is necessary upon initial installation and start- up to ensure system integrity. Power Supply Installation The Model S800 Power Supply must be housed in an MSHA approved enclosure. The power Supply has been designed for 120Vac use only. NOTE: Location of the permissible box on a hydraulic reservoir tank or other heat producing surface must be avoided. 3.3 S800 Installation Access must be provided for the cable to enter the right, left or back side of the S800 housing. Adequate clearance should be left for removal access of the electronics module. The location of the Model S800 should be protected by an overhanging part of the machine or a canopy provided for that purpose. NOTE: All cable must be MSHA approved or encased in MSHA approved conduit. Special considerations for S800 Locations: Mount the S800 where vibration and shock are minimized. Clearance must be provided for removal of the sensor as well as the S800 electronics module. Clearance must also be provided to the front display panel of the S800 for introduction of the magnet to the Calibration switch. Provisions must be made for access to the sensor for calibration of the S800. The sensor side of the S800 sensor housing should be angled downward to prevent accumulation of dust and water. A high percentage of sensor failures are directly related to poor selection in the location of the sensor. 7

12 The sensor should be protected from coal, or rock damage, water spray, oil and grease. A splash guard, P/N (UCISC# ), is provided for protection against water, oil and grease. Weld the shock mounting plate furnished by UCISC in location selected prior to mounting the S800 Monitor. Mount the S800 in place on the shock mounting plate. Bolting will facilitate easy removal in the event of damage. 3.5 S800 Terminal Connections All instrument wire connections to the Model S800 are made to the connector located in the base of the unit s explosion proof (XP) housing. The connector accepts 14 or 16 AWG stranded wire. Recommended strip length of the wire inserted into the connector is shown in Figure 1. Strip Length Figure 1: Wire strip Length Connections to the sensor and power supply are made via terminal blocks which are designed to accept spade lugged 14 or 16 AWG wire. Follow the color coded wiring connections in Figure Installation Check-Out Installation of the Model S800 system is now complete. Recheck all wiring installed in the permissible enclosure and/or the miner control box. Check to ensure compliance with Figure 2, and the mining machine manual. Ensure that it conforms to the wiring schematic applicable to the particular installation being made. Recheck S800 wiring for connection to proper terminals. 8

13 System power ON Test Ensure that all mining machine switches for main power, pumps, cutting heads, headlights, loading arms, etc. are OFF Energize mining machine cable main power and note the following. During a 20 second start-up, the digital display will show an increasing, then decreasing gas level as the sensor warms up and stabilizes. At the end of the 20 second start-up, the display may still indicate an elevated sensor level that will decrease to the present gas level. Additionally, the READY LED will light indicating system readiness. If the indicated gas level exceeds the Alarm or Warn set-points during start-up, the relays will not activate and the LED s will remain off. However, if the gas level is still elevated after the system has stabilized, the appropriate relay will be activated and the LED will light. The level the sensor ramps to during stabilization is directly related to how cool the sensor has become. The length of time off power and ambient temperature are contributing factors. 3.7 Sensor Locations The sensor should be mounted as close as practical to the miner cutting head. For longwall, one at the head gate and one at the tail gate. These are the recommended locations for Methane detection. In addition, there are certain considerations to be taken into account when locating sensors. The optimum sensor location is different for each application; and, therefore, the customer must evaluate conditions at the sensor site in order to make the proper determination. Generally: The sensor should be easily accessible for calibration checks. Ensure that sufficient clearance exists to allow the use of field calibration devices. The sensor head should always be pointing down and out of the direct blast of water spray to prevent water build up on the sensing element. The sensor should not be placed where it may be coated by contaminating substances. 9

14 Figure 2: Color Coded Wiring Connections 10

15 3.8 Sensor Poisons Sensors may be adversely affected by prolonged exposure to certain atmospheres. The important contaminants are: Silicones contained in greases or aerosols are the most common coating agents, which reduce sensor response. Prolonged exposure to Hydrogen Sulfide (H2S) gas. Halides compounds containing Fluorine, Chlorine, Bromine and Iodine. Heavy Metals (e.g., Tetraethyl Lead). Other damaging materials which attack the sensor physically include mineral acids and caustic vapors. The presence of such poisons and vapors does not exclude the use of General Monitors catalytic bead sensors, however, a careful analysis of ambient conditions should be aware that sensor calibration may need to occur at more frequent intervals. 11

16 4.0 Operation 4.1 Notice This chapter discusses what general maintenance to perform, electrical inputs/outputs, and re-setting alarm and fault. 4.2 General Maintenance Once the Model S800 has been installed, very little maintenance is required other than periodic checks to verify the integrity of the system. The minimum suggested calibration requirement is every 31 days. The power sensor and output wiring should be checked for tightness, verifying that all of the components and devices are connected correctly. SAFETY WARNING: Installation and maintenance must be carried out by suitably skilled and competent personnel only. 4.3 Electrical Inputs/Outputs The General Monitors catalytic bead sensor (field device) input is made to the terminal block at the base of the S800 XP housing (see chapter 3 for more detailed installation information). The sensor connections consists of the following three leads; Black = Reference Bead, White = Active Bead, Red = Sensor power. The Model S800 provides relay outputs for warn and alarm conditions. 4.4 Alarm Conditions The WARN and ALARM levels are preset at the factory. If the alarm levels require fine tuning, an UCISC service representative must be contacted to make the adjustment. At a factory preset of 1% gas by volume (20% LEL), the WARN LED will flash indicating the presence of the condition. In addition, the optional Remote Indicator Relay circuit will be activated. If WARN latching has been enabled, the WARN indication and relay circuit will not clear unless the Reset/Test Switch has been activated (Manual Reset). Otherwise, the WARN indication and relay circuit will clear as soon as the gas levels drop below the preset level (Auto Reset). At a factory preset of 2% gas by volume (40% LEL), the ALARM LED will flash indicating the presence of the condition. In addition, the Machine Cut-off Relay circuit will be activated. If ALARM latching has enabled, the ALARM indication and relay circuit will not clear unless the Reset/Test Switch has been activated (Manual reset), otherwise, the ALARM indication and relay circuit will clear as soon as the gas levels drop below the preset level (Auto Reset). 12

17 4.5 Latch/Non-Latch Alarm Re-setting Latched outputs is accomplished by applying the magnet to the Reset/Test switch (see Figure 10, sec for switch location). Activating the switch, as indicated by - - on the display, will reset any latched conditions that are no longer valid. Example: The sensor detects a gas concentration in excess of an alarm set point (trip Level). The associated alarm outputs will activate. After a few moments, the gas concentration drops below the alarm set point. If the alarm outputs are latched, the operator can activate the switch and the latched alarm outputs will return to their normal (safe) state. 4.6 LED Test Feature To activate the LED Test, the operator applies the magnet to the Reset/Test switch for five seconds, and then removes. All of the LEDs and LED segments in the digital will illuminate for approximately eight seconds. Ramp Test Feature To activate the Ramp Test simply apply the magnet to the Reset/Test switch longer than ten seconds. The digital display will begin ramping up at the start of the test and will continue to ramp up at a rate of 0.1/ second. NOTE: A faster ramp test (10 seconds total test time) may be set by an UCISC service representative. As each alarm set-point is exceeded, the ramp-up will pause 1 to 2 seconds then continue rising until the user deactivates the Reset/Test switch. The digital display will then begin ramping down, again pausing at each alarm activation set-point. The ramp test ramps up from the current gas level, and returns to the current gas level. Each alarm LED will light when the alarm set-point is exceeded. 4.8 Fault Diagnostics In addition to the Fault LED, the Model S800 provides a fault code on the digital display whenever a fault condition occurs. F2 Calibration failed, re-calibrate. If this fault occurs remove the gas, reset the fault code by actuating the reset/test switch and allow the gas to see clean or zero air for at least two minutes. Before attempting another calibration, ensure the following: Proper calibration gas being used Proper gas flow from the bottle Sensor is not blinded Splash guard is not fouled 13

18 If the second attempt fails, replace the sensor. If this fault continues to occur, consult United Central Industrial Supply. F3, F7 & F8 Check module. This fault occurs during initial power-up of the unit. If this fault occurs, remove and reapply power to the unit. If the fault continues to occur, replace the electronics module. F4 Check sensor. Sensor connections open or short circuited. Make sure the sensor wires are not damaged and are connected properly. If this fault continues to occur, replace the sensor and re-calibrate. F6 Low supply voltage. Make sure the supply voltage level at the S800 is 15Vdc ± 2Vdc. An unlatched F6 indicates momentary brown out or drop out of AC voltage. F9 - Communications Error. This error is displayed if the communications circuit of the S800 has been enabled and it does not receive a response from the external device. Check the wiring between the S800, pins 5 & 6 on the base connector and the external device. 14

19 5.0 User Interfaces 5.1 Notice This chapter discusses the user interfaces along with the Auto-Calibration Mode. Types of Interfaces User interfaces are provided so that the operator may interpret and direct the Model S800 in the performance of its various functions. User interfaces consist of (Figure 3): The digital display provides the user with the gas concentration at the sensor site, fault diagnostic codes, and auto-calibration prompts. The status indicators provide the user with an indication of the current mode of operation (alarm, warn, fault, ready and calibration). The Rest/Test and Calibration switches provide the user access to the LED/Ramp test and auto-calibration functions. Figure 3: User Interfaces/Displays 5.2 Auto-Calibration Mode To perform an auto-calibration, follow the procedure listed below. Place the calibration cup from the calibration kit (Use United Central calibration kit #543568) over the sensor with splash guard in place and apply zero air. Enter the Auto-Calibration mode by applying a magnet to the magnetic Calibration switch (see Figure 10, sec for switch location) until the CAL LED lights (about five seconds) then remove the magnet. The unit is now in the Auto-Calibration Mode (Figure4). 15

20 Figure 4: Entering Auto-Calibration Sequence When the magnet is removed from the Calibration switch, the digital display will indicate a flashing AC (Figure 5). Figure 5: AC Auto-Calibration Display The unit is now setting a zero value. When flashing AC becomes a steady AC (approximately 5 seconds), the zero value is now set. NOTE: zero-air must be used to establish a true zero value. Apply 2.5% by volume calibration gas. The display will change to CP. The calibration is now proceeding (Figure 6). Figure 6: CP Auto-Calibration Display After approximately two minutes, the display will change to CC. The calibration is now complete. Remove the calibration gas (Figure 7). The unit will return to normal operation when the gas level drops below "0.8% (16% LEL) 16

21 Figure 7: CC Auto-Calibration Display If the unit does not see gas or the unit cannot calibrate within six minutes, an F2 fault condition will be displayed. Activating the Reset/Test switch will reset the unit out of the F2 fault. The unit will return to normal operation with the previous calibration levels restored. Perform a Cal Check ( Bump test) by re-applying the 2.5% mixture of Methane in Air and note the response of the Warning and Alarm relays as well as the sensor output. The relays should energize per the ventilation plan and the sensor should respond between 2.3% to 2.7%. If not, recalibrate the system. 17

22 6.0 Sensor Assembly/Accessories 6.1 Notice This chapter provides a description of the accessories that are used with the model S Sensor Housing General Monitors offers an MSHA approved explosion proof housing, UCISC # that is rated for use in mines (Figure 8). Figure 8: Sensor Housing Drawing One end of the housing is tapped for use with a General Monitors sensor (3/4 NPT), while the other end is tapped for use with an MSHA approved packing gland. The set screws used to guard against vibration related loosening of both the sensor and packing gland nut most be in place during operation, otherwise the MSHA explosion proof approval is void. Once the sensor is installed/operating in the field, no attempt should be made to disconnect the sensor, the conduit or the housing lid without removing power from the Model S800 as such an act would compromise the explosion proof integrity of the field device. 6.3 Splash Guard General Monitors produces a universal splash guard, UCISC # that has been designed for use on all General Monitors combustible gas sensors (Figure 9). The splash guard prevents water from sprays or equipment wash-downs from being forced into the sensor cavity and affecting the response of the sensing element. Constructed of rugged Valox plastic, it has a series of internal baffles to deflect water down and away from the sensor. This guard is also threaded for simple screw on installation. 18

23 The splash guard is recommended for reducing dust and rock damage to the sensor head. The S800 MUST be calibrated with the splash guard in place. 6.4 Dust Guard Assembly Figure 9: Splash Guard, Picture The Dust Guard Assembly (UCISC #452328) is a simple, threaded stainless steel cylinder with a wire screen at one end. It is easily removed for cleaning and/or replacement of the disposable screen. This General Monitors accessory is specifically designed to prevent dust and particulate matter form reaching the sensor flame arrestor. Such debris can plug the screen and limit the amount of gas reaching the active surface of the sensor. Figure 10: Dust Guard The Dust Guard is also available in a kit (UCISC #543204) with twelve replaceable screens (Figure 11). Figure 11: Dust Guard Kit 19

24 6.5 Calibration Equipment To calibrate the Model S800 use the Calibration Kit UCISC# The calibration procedure and use of the Calibration Kits explained in section

25 7.0 Technical Information 7.1 Spare Parts UCISC P/N Description Power Supply: Power Supply, S800, 120VAC Hold Down, Pwr Supply Fuse, 3/4A 600V Sensor Housing: Washer, Locking Screw, Gland/Sensor Locking Screw, Detector Hsg Cover Screw, Mounting, Term Block Sensor, Aluminum Hsg Splash Guard, Molded Plastic * Optional, Splash Guard, Aluminum * Optional, Dust Cap, SS, w/screen" Housing, Detector w/o Sensor Cover, Sensor Housing Block, Terminal 3 Pos O-Ring, Sensor Housing Electronic Module: Screws, 2.5 x 8mm, Connector Screws, 6-32 x ¼, Wire Guard Module, Electronic, Red S800, Module w/base, Red Post, Module Guide Wire Guard, Assy Base Assy, Readout Magnet, Calibration, S Conn, 12 Pos, Base Assy O-Ring, Readout Housing 21

26 7.2 S800 Tool List Used On Tool Power Supply: /8 slotted screw driver or ½ socket with 4 in.ext. Sensor Housing: /8 hex handle or l-key /16 open wrench #2 Phillips screw driver in crescent wrench Electronic Module: #1 Phillips screw driver /16 Hex T-handle pr L-key with 2 in. long stem minimum /16 open wrench #2 Phillips screw driver* /8 slotted screw driver* Terminal Blocks 1/4 slotted screw driver* * Any of these tools may be used on the Terminal Block Screws. 22

27 7.3 Electronic Module Module Removal Screws Reset Test Switch Calibration Switch Module Removal Screws Figure 12: Electronic Module 23

28 7.4 Module Base Assembly Figure 13: Module Base Assembly 24

29 7.5 Power Supply Assembly Figure 14: Power Supply Assembly 25

30 7.6 Detector Housing Assembly Figure 15: Detector Housing Assembly 26

31 8.0 MSHA Installation Letter Mine Safety and Health Administration Approval and Certification Center Box Route 1 Industrial Park Road Triadelphia, West Virginia Company: Mine: Address: Attention: Health and Safety Technical Approval and Testing Gentlemen: We have installed an S800 Methane Monitoring System, M.S.H.A. Cert. #32A-23/MS-0a (manufacturer), type (number) serial number: This machine is operated on (voltage) and carries M.S.H.A. approval number The installation was made in accordance with the manufacturer s instructions & safe practices. The physical position of mounting is as shown on the following sketch. Top View Mining/Cutting heads or Loading arms Front Longwall (Top View) National Mine Service System Part No. is the attached drawing. Unit was installed by Details of the monitor system are shown on Unit was calibrated by Please grant extension of approval for this machine. Very truly yours, Name: Title: Date: Original copy for operator s records. Send two copies to local MSHA District Office. 1 copy for local district office records. 1 copy to be forwarded to A&CC. 27

32 ADDENDUM Product Disposal Considerations This product may contain hazardous and/or toxic substances. EU Member states shall dispose according to WEEE regulations. For further General Monitors product WEEE disposal information please visit: All other countries or states: please dispose of in accordance with existing federal, state and local environmental control regulations. 28

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

Combustible Gas Transmitter 65-2400RK-05

Combustible Gas Transmitter 65-2400RK-05 Combustible Gas Transmitter 65-2400RK-05 Overview This detection insert describes the combustible gas transmitter. This insert also describes how to install, start up, maintain, and calibrate the transmitter.

More information

INSTRUCTION MANUAL MODEL PCD-88

INSTRUCTION MANUAL MODEL PCD-88 INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Tipping Bucket Rain Gauge Models 6011-A 6011-B Tipping Bucket Rain Gauge Models 6011-A 6011-B User s Manual 1165 National Drive Sacramento, CA 95834 800.824.5873 Table of Contents General Information... 1 Introduction... 1 Installation General... 2

More information

RAEGuard EC FGM-13XX

RAEGuard EC FGM-13XX RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

Installation Instructions

Installation Instructions 520 Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual

More information

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

MTX-D, Oil Temperature/Pressure Gauge

MTX-D, Oil Temperature/Pressure Gauge MTX-D, Oil Temperature/Pressure Gauge 1 Mounting and Sensor Installation... 3 1.1 Mounting the Gauge... 3 1.2 Oil Temp Sensor... 3 1.3 Oil Pressure Sensor... 3 2 Wiring... 3 2.1 Main Gauge Wiring... 4

More information

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity

More information

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while

More information

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL. Manual Part Number 80003-035 MCN-389, 01/21/08

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL. Manual Part Number 80003-035 MCN-389, 01/21/08 PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL Manual Part Number 80003-035 MCN-389, 01/21/08 Table of Contents 1.0 Introduction...1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1

More information

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

ECO SENSORS, INC. OZONE SENSOR AND MONITOR ECO SENSORS, INC. OZONE SENSOR AND MONITOR Model A-22 11-07 INSTRUCTIONS FOR USE Sensor Rubber boot to protect against mechanical damage. Data and power jacks on the side. SM-X precalibrated sensor module.

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Machine Safety Switch: SI-LM40 Series Limit Switch Style Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 6 Tipping Bucket: RG200 02/05/10 01-343 - 1 - Congratulations on your

More information

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet Introduction BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet The GasAlertMicroClip Soft Tools application is required to configure the GasAlertMicroClip detector ( the detector ). Software/Hardware

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

EX-5175-EC Sensor/Transmitter Manual

EX-5175-EC Sensor/Transmitter Manual PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com EX-5175-EC Sensor/Transmitter Manual Manual Part Number 80003-099 MCN-13-008, 11/06/13 Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack... 1 1.2 Check

More information

ExStik TM ph Waterproof Meters

ExStik TM ph Waterproof Meters User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL

More information

PL-1, Pocket Logger 11-0135B

PL-1, Pocket Logger 11-0135B PL-1, Pocket Logger 1 PL-1... 2 2 Wiring... 3 2.1.1 Single Innovate Device Relay Wiring Instructions... 3 3 Mounting... 4 4 Connecting the PL-1 to the MTS serial chain... 4 5 Recording... 5 6 LogWorks...

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Comfort Control Relay Panel (CCRP)

Comfort Control Relay Panel (CCRP) CCRP9 "Commitment to Innovation" OPERATION & INSTALLATION GUIDE FOR Comfort Control Panel (CCRP) Off-Peak System Control 9 Pole CCRP 4 Pole CCRP (Applicable to Software Version 14.0-14.9) "Manufactured

More information

i ChatterBox! Motorcycle Security

i ChatterBox! Motorcycle Security i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before

More information

600-GD & 600-GDL 600 SERIES GAS DETECTOR

600-GD & 600-GDL 600 SERIES GAS DETECTOR 600-GD & 600-GDL 600 SERIES GAS DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS This page has been deliberately left blank. Page 1 Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

PART 1 - INTRODUCTION...

PART 1 - INTRODUCTION... Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

EzFlex Combustible Gas Leak Detector Model EZ40

EzFlex Combustible Gas Leak Detector Model EZ40 User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible

More information

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015 Fax: (562) 431-8507 www.flowline.com 22 AUG

More information

GAS SAFETY PRECAUTIONS

GAS SAFETY PRECAUTIONS GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.

More information

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector

More information

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual GreenWay Solar LED Path and Trail Lighting System Installation and Owner s Manual Important Notes and Warnings This installation and instruction manual provides installation, operation, and maintenance

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that this installation be carried

More information

SEC 1500 Gas Detector Instruction Manual

SEC 1500 Gas Detector Instruction Manual SEC 1500 Gas Detector Instruction Manual 1 I. SPECIFICATIONS Table of Contents II. III. IV. GENERAL DESCRIPTION DETAILED DESCRIPTION Enclosure Controls and Indicators Calibration/Reset/Date Switch Optional

More information

Industrial Ringdown/Autodialer Telephone SCR Series

Industrial Ringdown/Autodialer Telephone SCR Series Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

3000W Power Inverter

3000W Power Inverter 3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

TITAN 13 x 2 ½ BRAKES

TITAN 13 x 2 ½ BRAKES INSTALLATION INSTRUCTION AND SERVICE MANUAL Actuator/Trailer Dealer - Please provide these instructions to the consumer. Consumer - Read and follow these instructions. Keep them with the trailer for future

More information

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output 133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame

More information

DSM155 Digital LED Light Meter User s Manual DSM155

DSM155 Digital LED Light Meter User s Manual DSM155 DSM155 Digital LED Light Meter User s Manual DSM155 CONTENTS TABLE OF CONTENTS......3 LIMITED WARRANTY AND LIMITATION OF LIABILITY......3 Out of Box....3 Accessories....3 Safety Information....3 Certification....5

More information

Sensor for Ammonia. 11511 West 83 rd Terrace email sales@manningsystems.com. 1.800.444.9935 or 913.894.1185. fax 913.894.1296

Sensor for Ammonia. 11511 West 83 rd Terrace email sales@manningsystems.com. 1.800.444.9935 or 913.894.1185. fax 913.894.1296 EC-F2-NH 3 Sensor for Ammonia Instruction and Installation Manual Rev H MOUNT ENCLOSURE THIS END UP. DO NOT BLOCK PERFORATED VENT HOLES. SENSOR 11511 West 83 rd Terrace email sales@manningsystems.com Lenexa,

More information

User Guide. HDMI Active Cable Extender. DVI-7370c

User Guide. HDMI Active Cable Extender. DVI-7370c User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING

More information

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel) SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically

More information

VARIO PROX CARD READER INSTALLATION MANUAL

VARIO PROX CARD READER INSTALLATION MANUAL VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

BEP FD-2 CONTOUR MATRIX FUME DETECTOR BEP FD-2 CONTOUR MATRIX FUME DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING GAS SENSORS...3 4 FEATURES...4 5 SPECIFICATION...4 6

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Installation guide H-5500-8554-03-A. HSI hardwired system interface

Installation guide H-5500-8554-03-A. HSI hardwired system interface Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any

More information

PUSH BUTTON START INSTALLATION MANUAL

PUSH BUTTON START INSTALLATION MANUAL PUSH BUTTON START INSTALLATION MANUAL ALTHOUGH THIS PRODUCT HAS BEEN THOROUGHLY TESTED KPIERSON TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE THAT MAY RESULT BY THE INSTALLATION OF THIS PRODUCT.

More information

el-720 Carbon Dioxide Gas Leak Detector User s Guide

el-720 Carbon Dioxide Gas Leak Detector User s Guide el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Threaded Inline Air Heaters

Threaded Inline Air Heaters Threaded Inline Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow

More information

Wireless Indoor/ Outdoor Thermometer

Wireless Indoor/ Outdoor Thermometer Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13 CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions

More information

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Series B14 Monitor System

Series B14 Monitor System Series B14 Monitor System Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Road, Delph Saddleworth

More information

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE

More information

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC. BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

How To Use A Cdm250 Digital Multimeter

How To Use A Cdm250 Digital Multimeter User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

Leak Detection System

Leak Detection System Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH

More information

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info OSXL-100-PE Thermal Imaging Camera Enclosure Introduction Please read this manual completely

More information