1 Department Name Filling Building # Page No Page 1 of 27 Issued By (Q.A ) : : Production Manager : : INDEX No Description Page No Summary of Process Summary of Activities Batch Formulation Thawing of Bulk Antigen Lyophilizer Trays Processing Rubber Stopper Processing Processing Product contact Material for Pooling & Filling Vial Processing Room Pressure Recording Preparation of Lyophilizer Verification of Bulk Antigen Container Weights. Pooling & Clarification of Thawed Bulk and Preparation of Final Bulk Integrity Testing of Product Filter Filling Integrity Test of Vent Filters Loading of Lyophilizer Lyophilization Aluminum cap processing Sealing of vials Material Reconciliation record Bulk reconciliation record BMR Certification

2 Department Name Filling Building # Page No Page 2 of 27 The entire activity has the following major steps: Activity Day No Thawing of Bulk Antigen 2. Cleaning and Sterilization of Lyophilizer Trays 3. Sterilization and Drying of Rubber Stoppers 4. Cleaning, Preparation and Sterilization of Material Required for Filling and Pooling 5. Cleaning and Sterilization / Disinfection of Lyophilizer 6. Washing and Sterilization of Vials 7. Pooling and Clarification to Prepare Final Bulk 8. Filling of Vaccine into Vials 9. Loading of Filled Vials in the Lyophilizer and Lyophilization 10. Sterilization and Drying of Aluminium Caps 11. Sealing Day 1 Day 2 Day 3 Day 4 Day 5 Day before filling Day of filling Day after filling 2 nd day after filling 3 rd day after filling Sealed vials with lyophilized vaccine are handed over to Screening Dept. for visual inspection. Pages 5 and 6 to be issued to Bulk section who will fill the details and send it back. Pages 25 To 27 to be issued to Lyophilization section who will fill the details and send it back.

3 Department Name Filling Building # Page No Page 3 of 27 SUMMARY OF ACTIVITIES Target Lyophilizer Number XXXX Lyophilizer Batch Capacity Vials Volume per vial ml (23) Batch Volume as Dispensed Bulk Mfg Dept L (24) of Filling dd/mm/yyyy Fill volume per vial (xx x xx) (Overfill mid point at +X %) ml (25) Batch Volume as Rechecked Filling Dept L Theoretical Batch Size Vials (28) Approx Filling Yield. [Quantity loaded in Lyophilizer] Vials (22) Approx Sealing Yield. [Quantity transferred to screening] Vials (19) Note: Acceptable variation between 24 and 26 which is caused removal of outer packaging / double bagging should not be more than ± X % Activity: BATCH FORMULATION Ref SOP No: Select the bulks for the batch on the basis of bulk Ag titre, volume, filling volume per vial, and batch size. Filling personnel* to cross check in terms of Weights on receipt. Component Bulk Ag No. Antigen Titre Vol. L *Gr Wt kg Tare Wt kg Limit XX L ± X% Actual Vol. L kg kg Set Ag Titre / vial Volume / Formulation: Dt: Weighing: Dt: Product X vial Done Checked Done Checked X ml Remarks:-

4 Department Name Filling Building # Page No Page 4 of 27 Activity : THAWING OF BULKS Ref SOP NO: The Bulks should be removed for thawing not more than xx Hours prior to estimated time of start of filling. THAWING DETAILS Particulars Product #12 Diluent Removed for thawing on (date) Location of cold room Bldg No CR No Bldg No CR No Removed for thawing at h h Incubator set temp ºC ºC (Range xx to xx C) Thawing completed on (date) Thawing completed at h h No Handling of Bulk Antigen Containers Done By Name Initials Bulk Antigen Containers Received By: Remarks if any:

5 Department Name Filling Building # Page No Page 5 of 27 Activity : LYOPHILIZER TRAY PROCESSING Ref SOP No : 1. Clean the trays to be used for collecting filled vials using a clean lint free mop wetted with WFI/xx % Isopropyl alcohol. 2. The trays can be processed in either of two ways A) Load the cleaned trays on the dry heat sterilizer (DHS) trolley, as per validated max loading pattern in DHS No xxxx and sterilize at xxx C, xxx minutes B) Load the trays in Autoclave and sterilize at xxx C ± x C for XX minutes No of Trays Pattern No Pattern No 3. If option A above is selected, run the cycle to hold the trays at xxx C for xxx minutes. Normal variation x to + x C 4. Write Product, B.No., Charge No & date on the sterilizer thermograph/printout (for Option A only) sign it and attach it to this BMR No Description of Activity Done By Checked By 1 No of trays cleaned Quantity for batches: 2 Loaded cleaned trays onto the trolley. Loaded in Sterilizer Load pattern no Charge No # xxxxxx xxxx xx # xxxxxx xxxx xx Checked Cycle parameters A) xxx C, xxx minutes B) xxx C ± x C for xx minutes 3 Sterilization temperature xxx C achieved at h (applicable for option A above) 4 Sterilization temperature xxx C maintained till h (applicable for option A above) Remarks:-

6 Department Name Filling Building # Page No Page 6 of 27 Activity : RUBBER STOPPERS PROCESSING Ref SOP No : 1. Verify that QC approved stoppers of correct type have been taken for de-cartoning. 2. For RFS stoppers, after de cartoning directly move to sterilization. 3. Load stoppers as per validated loading pattern given below RFS Max No of stoppers / pouches xxxx Pattern No for Autoclave X xxxx Pattern No for Autoclave Y xxxx 4. The stoppers can be processed in either of the two ways: A) Sterilization in Autoclave X (xxx to xxx C) and drying in dry heat sterilizer (DHS) No B) Sterilization and drying in Autoclave Y. In both the cases, carry out sterilization at 121 C for xxx minutes, Write Product, B.No., Charge No and date on the sterilizer printout / thermograph sign it and attach it to this BMR 5. If option A above is selected, then transfer the sterilized rubber stoppers from the autoclave to the DHS from clean room side for drying. Start drying cycle: xxx C for xxx mins. Normal variation - x C to + x C/ ± x min. If option B above is selected then Sterilize stoppers at xxx C ± x C for xxx minutes followed a drying cycle for xxx mins in the autoclave. In case of greater variation in temperature or time, the deciding factor will be the moisture content. Write Product, B.No., Charge No and date on the sterilizer thermograph /printout (for Option A only) sign it and attach it to this BMR. 6. Draw one sample for Moisture content analysis (Limit NMT xxx mg/stopper). In case stoppers of 2 batches are sterilized in 1 load, draw only 1 sample, record both batch nos on TRF, attach copies to both BMRs A) Stopper input: xx mm, Lyo Grey Butyl Rubber 1) Unprocessed b/f: B.No 2) Processed b/f: B.No 3) Fresh quantity issued Actually Loaded for Sterilization 9) No of stoppers Pouches 4) Fresh used from issue 5) Option for Process A =1+2+4 B =1+4 Unprocessed Done Checked Remarks:

7 Department Name Filling Building # Page No Page 7 of 27 Activity : RUBBER STOPPERS PROCESSING, cont'd Ref SOP No : 7. Load pouches on the Autoclave trolley as per validated loading pattern. Autoclave No. / Equipment No. Charge No. Load Pattern No. Program No. ######## XX XX X ######### XX XX X Quantity for 1 / 2 batches Done Checked DHS No / Equip No #################### Charge X No.: Drying temperature xxx C for xxx minutes for drying in DHS Done Checked Achieved at : h Maintained till: h Sample for Moisture Content (11) Nos. NOTE: Filling activity should not be started before the result of moisture content estimation is received from Q.C. Remarks:

8 Department Name Filling Building # Page No Page 8 of 27 Activity : PROCESSING PRODUCT CONTACT MATERIAL FOR POOLING AND FILLING Ref SOP No : 1. Use filters based on the following table for B.Size for Filtration> xx L 2. Carry out pre-filtration integrity test using the following data INTEGRITY TESTING OF xx µm FILTER Make Name Part No Quantity/ Bubble Point Diffusion batch A B Tst pr. Rate XXXX xx 1 xx 2 xx 3 YYYY yy 1 yy 2 No bubbles at A, Bubbles should be seen < B, Units: BP, Diffusion Pr: Bar, rate: ml/min A) Pre-Sterilization Integrity Testing Application Stage Method Equipment Equipment No Test Type Step A Presteriliz n Manual XXXX Bubble Pt Auto XXXX Diffusion Filter Details Mfg/ Brand Part No Pore Size Wetting Liq. Test Parameter XXXX xx um WFI XXXX Filter Lot No Filter S.No Observation Result Done Check Bubbles seen at bar Printout attached Remarks:-

9 Department Name Filling Building # Page No Page 9 of 27 Activity : PROCESSING PRODUCT CONTACT MATERIAL FOR POOLING AND FILLING Ref SOP No : 1. Inactivation: Inactivate the Material used for Pooling and Filling in the Autoclave heating it to xxx C for x minutes. Record in the autoclave Log Book. (Variation xx C to xx C) 2. Preparation: Unload the inactivated material from the Autoclave on the Washing room side; Wash inactivated material passing Cooled WFI. Draw a sample from the tanks & check conductivity. Draw samples from Tanks, Silicon tube to header, Header, Syringes, needles & screen for particulates. In case the previous product is Media fill, draw additional samples submit to QC with Product Changeover TRF. On clearance wrap in sterilization pouches. 3. In case the vent filters on BV2 are new, carry out WIT and attach the results on opposite page. In case they continue from the previous day, the Post use integrity test of the previous batch will be treated as the pre-use integrity test of this batch. 4. Check the plan for the next day & select the loading pattern. Load the wrapped material on the autoclave trolley as per validated loading pattern. Attach a list of material sterilized, to this BMR. Write Product, B.No., Charge No and date on the sterilizer printout / thermograph (for Autoclave XX only) sign it and attach it to this BMR. Conductivity check on product tank rinse sample NMT 1 ms/cm Check xx BV1 BV2 Product C/O Done Checked ms/cm ms/cm ms/cm ms/cm NA TRF attached Visual Inspection of Product Contact material rinse sample Item BV 1 BV 2 Silicon tube Header Syringe Needle Fibres Particles Sampled : Screened : STERILIZATION OF MATERIAL FOR POOLING AND FILLING 1 Autoclave No / Equip No ######### / ######## Done Checked 2 Load Pattern number XXX XXX 3 Charge No XX XX 4 Program No XXXXX XXXXX Remarks:-

10 Department Name Filling Building # Page No Page 10 of 27 Activity : VIAL PROCESSING WASHING Ref SOP No : 1. Verify that QC approved vials of correct type have been taken for de-cartoning. 2. De-carton the Vials, transfer them into clean SS trays and pass them to the washing area. 3. Ensure WFI cooling assembly is sanitized before commencing Washing of x st batch. Ensure pressure of Fresh and Recycled WFI and compressed air, conductivity of Fresh WFI are within limits. Ensure area is free of previous product vials 4. Perform Test for Adequacy using X washed vials. 5. After operation is completed, drain the WFI assembly and clean the machine A) Vial input: x ml, xx mm X xx mm height, (Amber, tubular, USP type-1) 1) Unprocessed b/f: B.No 2) Processed b/f: B.No 3) Fresh qty issued 4) Fresh used from issue Done By Checked 5) Option for A= ) Taken for washing: - Process B=1+4 B Pre-washing and Washing operation checks: Done By WFI cooling Line Clearance WFI WFI Temp ass ly sanitized Checked Conductivity (xx to xx C) (NMT X ms/cm) Yes / No Yes / No ms/cm C Washing Media Outlet Fresh WFI Recycled Comp. Air Pressure (Range Bar ) WFI Set XXXXXXX xx - xx xx - xx xx-xx ########## Observed (Bar) Washing Started at : h Completed at: h Adequacy Sampled Results Time Pass / Fail h C Vial Output (7) Sampled (8) Rejected For Sterilization 6 - (7+ 8) = 9 Unprocessed 18 = 3-4 Remarks Checked

11 Department Name Filling Building # Page No Page 11 of 27 Activity : VIAL PROCESSING STERILIZATION Ref SOP No : 1. At the start of washing activity, ensure there is enough paper in the printer and a fresh circular chart is placed in the recorder. Ensure that the set points of the Heater Banks of the Tunnel Sterilizer are as per the following chart. Charge no: SET TEMPERATURES OF HEATER BANKS Heater Bank No S1 S2 S3 S4 S5 S6 S7 S8 Done Checked Temperature ºC 2. At the start of washing for the day, after the vials have reached the exit gate of the sterilization zone, the conveyor of the Tunnel shall automatically stop for ten minutes. This event shall be printed the controller. 3. The conveyor speed at the start of the washing i.e. till the vials reach the infeed of the filling machine should be xx Hz. Thereafter it will automatically switch to xx Hz. This event shall be printed the controller. No Description of Activity Time Done By Checked 1 Tunnel sterilizer started at h 2 Minimum set temperature (xxx C) achieved at h 3 xx Minute hold h to h* 4 Tunnel Set to Night operation (Process End) h 4. Attach the printout and circular chart to the BMR. Operators Washing and Sterilization:- Remarks:- * x st / x nd batch of the day.

12 Department Name Filling Building # Page No Page 12 of 27 Activity : VIAL PROCESSING STERILIZATION, continued Ref SOP No : 1. Check the pressures of the three zones of the tunnel, at least once, preferably at start of washing. If the pressures are not within the range given below, immediately stop washing activity and inform the Officer in charge 2. At the end of washing, perform sanitization of the bulk WFI cooling assembly 3. Write the Product, B.No., Charge no and date on the sterilizer printout / graph,sign it and attach it with this page of BMR. CHART SHOWING THE PRESSURES OF THE VARIOUS ZONES OF THE TUNNEL #XXX Drying Zone Sterilization Zone Cooling Done Checked Time Pressure Range (P1) mm wg (P2) mm wg Zone (P3) mm wg Observed Observed Remarks:- xx --xx xx --xx xx --xx Activity : ROOM PRESSURE RECORDING Ref SOP No. 1. Record Room differential pressure before entering the clean area for pooling and filling. No Room & range Observed value (Pa) 1. PAL 1 (xx-xx) 2. PAL 2 (xx-xx) 3. PAL 3 (xx-xx) 4. Filling (xx-xx) 5. Tunnel Room (xx-xx) 6. Sealing (xx-xx) 7. Pooling (xx-xx) Done Checked Time Remarks:

13 Department Name Filling Building # Page No Page 13 of 27 Activity: PREPARATION OF LYOPHILIZER Ref SOP No.: 1. After Unloading, Carry out cleaning of Lyophilizer and record in the BMR 2. Carry out Sterilization / Disinfection as below: A week 1 denotes 6 working days with the day the Lyophilizer gets Steam Sterilized/Steamed being declared the 1 st day of the week and the batch filled after steam sterilization/ steaming the 1 st batch. If the third batch is to be loaded later than the 6 th day of the week, it is treated as the first batch of the next week. The gap between Sterilization/disinfection step and loading should not be more than xx hours. For Lyophilizer No. A, B, C Batch Before Loading /week 1 1 st batch of week 2 nd batch of week 3 rd batch of week Lyo A Lyo B, C Lyo A, B, C Lyo A, B, C 3 Steam Exposure xxx mins Steam Exposure xxx C, xx mins Disinfection with XXX Disinfection with XXX 2 Steam Exposure xxx mins Steam Exposure xxx C, xx mins Disinfection with XXX 1 Steam Exposure xxx mins Steam Exposure xxx C, xx mins In case there is a change of product, with the virus of the current product not in the present product, the lyophilizer should be sterilized. Display boards: Cleaned, ready for Steam Exposure, and Disinfected with XXX ready for evacuation after Steam Sterilization, Steaming and treatment with XXX respectively. No Description of Activity Done By 1 Lyophilizer No: - Cleaning done after unloading of Product /Batch.No: 2 Remarks:- Strike out what is not used Steam Exposure Steam Exposure xxx mins xxx C, xx mins XX disinfection Checked

14 Department Name Filling Building # Page No Page 14 of 27 Activity : VERIFICATION OF BULK ANTIGEN CONTAINER WEIGHTS Ref SOP No.: 1. Unwrap the outer packing of the thawed bulk antigen containers 2. Check the Bulk antigen container numbers and record their gross Weights in the Batch Formulation Sheet. 3. Carry out surface disinfection and transfer them to clean room, through hatch. Net Weight of Formulation (Gross Tare on Page 5) Weight in g /ml (B) (From Page 20) (Same as kg /L) Net Volume of formulation (Net Wt / kg/l) kg kg/l (26) L Remarks:- Done Checked Activity : POOLING & CLARIFICATION OF THAWED BULK AND PREPARATION OF FINAL BULK Ref SOP No : 1. The contents of the Bulk antigen containers are pooled in a sterilized, SS blending vessel, with the jacket at a temperature NMT XX C. Start the magnetic stirrer (xxx to xxx rpm) after the level of bulk antigen inside the tank has gone above the impeller. If the temperature of the pool exceeds xx o C, immediately shut off the heating immersion circulator and the magnetic stirrer. 2. The pool of bulk antigens is clarified using a sterilized xx µm filter capsule/s. The outlet of the xx µm filter/s is connected to a 2 nd sterilized SS blending vessel with the jacket at a temperature of XX XX C. Clarification should be started only after the temperature of the pool is in the range of XX XX C for xx minutes. The contents of the second SS blending vessel will be the final bulk for the batch. No Particulars Done Checked 1 Bath temp before Pooling Pooling: xx-xx C Start End Blending vessel C h h A 2 Clarification: Temperature of Stirrer A, B Pool Final Bulk RPM Start time End time xx - xx C xx - xx C xxx-xxx C C h h 3 Filtration Residue (29) Sampled Bulk (30) ml XX ml x X bottles = XX ml Remarks:- B

15 Department Name Filling Building # Page No Page 15 of 27 Activity : POOLING & CLARIFICATION OF THAWED BULK AND PREPARATION OF FINAL BULK Ref SOP No : 1. Check the integrity of xx µm filter capsule bubble point method. Connect the SS blending vessel with the final bulk to the glass header only after the integrity test is done and the filter capsule has passed the test. 2. Inactivation: Inactivate the Material used for Pooling in the Autoclave heating it to XXX C for X minutes. (Variation permitted XX C to XX C) 3. Perform the environmental monitoring activities as per SOP No. This includes exposing settle plates, contact plates and Air sampling as per location map, Swabs of critical surfaces, Finger dabs of operators involved in pooling & filling operation FILTER INTEGRITY TESTING Application Stage Method Equipment Equipment No Test Type Clarification Post-Clarific n XXXXX XXXXX ######## Bubble Pt Filter Details Mfg/ Brand Part No Pore Size Wetting Liq. Test Parameter Filter Lot No Filter S.No Observation: bar Pooling material Autoclave No: Charge no: Inactivation Result Done Checked Done Checked Remarks:-

16 Department Name Filling Building # Page No Page 16 of 27 Activity : FILLING Ref SOP No.: 1. Volume per vial (23) is indicated on page 5 of this BMR. The Volume per vial is the lower limit of the permitted volume range. The upper range is calculated adding X % of the Volume per vial. The weight range is derived from this volume range multiplying it with weight/ml of the bulk. Calibrate the balance to be used for verifying the Fill volume. 2. Check for absence of previous product components. Carry out the priming of the header and the pumps, collect the priming liquid and send as sample of final bulk to Q.C. No Description of Activity 1 Volume / vial (23), Pg 5 XX ml 2 Weight per ml Calculation Volume Wt (Bulk WFI) (C) XX ml g 3 Volume Range to weight range setting Lower Vol. Limit (23) Upper Vol. Limit (23) x XXX=(E) Balance Calibrated YES / NO Wt (Final bulk) (D) g Lower Wt Limit (23) x (B) Line Clearance: Wt/mL (D/C) = (B) Upper Wt. Limit (E) x (B) Done Checked 4 XX ml XX ml g g Sampling for Visual Inspection (Sample size: XX vials) Fibre Black Part. White Part. Glass Total (%) 5 Filling activity : Filling machine XXXXXXXXX Room Started at Room Completed at Temp C Temp C Rh % h Rh % h Remarks:

17 Department Name Filling Building # Page No Page 17 of 27 Activity : FILLING Ref SOP No.: Rejection Quantity Vials (12A) Sample to QC Stopper (12B) (13) XX Total Loaded in Lyophilizer Done By Filled Appr. Vials Trays Vials (F) F- (G) (12A+13)=22 Checked Stoppers rejection details (12B=R1+R2) Balance processed (17) During filling (R1) Balance in hopper (R2) Vials Nos Stoppers Nos No Description of Activity Done By Checked 6 Rejection Inactivation details Autoclave No: Charge No: Operators: I Shift II Shift III Shift ID numbers of syringes used for filling STATION NUMBER Remark :

18 Department Name Filling Building # Page No Page 18 of 27 Activity : FILLING Ref SOP No.: 1. At the start of filling, reject the vials used for checking the centering of filling needles, volume setting etc. (Reject Not less than first xx vials) Syringe Number Attach Fill Volume Print or record manually, on weight basis, every xx Minutes Time (h) Water bath temp xx-xx 0 C Done *Checked * Fill in case no printout is available, otherwise sign on printout Remarks:-

19 Department Name Filling Building # Page No Page 19 of 27 Activity : INTEGRITY TESTING VENT FILTERS Ref SOP No.: 1. On completion of the Filling activity, carry out integrity testing of the two vent filters (XXXX) of the Blending vessel tank attached to the filling machine WIT method. 2. Fill the upstream side with WFI at xx-xx o C. A hold at xxxx mbar should not produce an intrusion rate greater than xxx ml/min 3. Attach printouts below:- Remarks:-

20 Department Name Filling Building # Page No Page 20 of 27 Activity : LOADING OF LYOPHILIZER Ref SOP No.: 1. Ensure that the Lyophilizer to be loaded has been cleaned and Sterilized/disinfected, the date of loading should not be later than the date on the board (Pg.no 16) 2. The trays containing filled and half stoppered vials are to be transported to the Lyophilizer in a mobile class 100 trolley 3. Ensure that the temperature of the Lyophilizer shelves is xx ºC before loading of trays containing filled and half-stoppered vials. 4. After all the trays have been loaded in the lyophilizer, inform lyophilizer operator on duty. He will check the loading of the lyophilizer, insert product temperature probes and close the door of the lyophilizer. No Description of Activity Done By Checked 1. Checked, that Lyophilizer is Sterilized / Disinfected 2. Checked that Class 100 trolley is Switched ON 3. Vials Loaded in Lyophilizer No: Remarks:- Vol. Per Vial (23) xx ml Lyo. No:- Loading date Recipe No. Sterilization Details (see page 15) For Filling Dept: Lyophilizer B, C: 1 st Batch Steam Steriliz n. Lyophilizer A: 1 st Batch Steaming. 2 nd Batch / 3 rd Batch All Lyophililzers XX disinfection

21 Department Name Filling Building # Page No Page 21 of 27 LYOPHILIZER CHAMBER CLEANING, DISINFECTION AND STERILIZATION: 1. For Lyophilizers B and C, If Status board Cleaned, Ready for Steam exposure is displayed on clean room side, evacuate chamber to xxx mbar (Water ring vac pump: WP), followed steam exposure at xxx - xxx C for xx minutes. 2. For Lyophilizer A, If Status board Cleaned, Ready for Steam exposure is displayed on clean room side, evacuate chamber to xxx mbar (WP), followed steaming for xx mins. 3. Above steps are followed drying of chamber with WP for minimum xx mins. 4. For all Lyophilizers, If status board Disinfected with XXX, Start evacuation is displayed on clean room side, carry out evacuation as per SOP (XXX cycle: xx min evacuation vacuum pump with shelf at xx C) No Description of Activity Done By 1. Status board: Lyo B and C:'Cleaned, Ready for Steam Exposure Process xxx - xxx C maintained Process Start Start End End h h h h 2 Status board: Lyo A:Cleaned, Ready for Steam Exposure Vacuum Pull down Started xxx min Exposure Drying Start End Steam Start End End h h h h h h Drain temperature at the end of Steaming: C 3 Status board: Disinfected with XXX, Start evacuation Shelf temp. +xx C Evacuation with vac pump attained at Start End h h h 4. Display Board: Ready for Loading up to: 5. SHELF PRE-COOLING: (Set Shelf temperature: -xx C). yy C attained: h. Inform production dept. the achievement of yy C displaying the status board indicating time of attaining temperature 6. CHECK LOADING OF VIALS ON SHELVES (SOP No. ) No of shelves Loaded Loading end Time No. of product Door closing temp. Probes time h h

22 Department Name Filling Building # Page No Page 22 of LYOPHILIZATION CYCLE DETAILS Step Freezing Condenser Chamber Primary Sec. Drying cooling Evacuation drying Shelf Temp - xx C NA NA -xx to xx C xx C Start Time End Time Duration X / X x ± x h x h x h xx ± x h x ± x h Norm X x ± x h x h x h 8 BATCH STOPPERING AND UNLOADING Ensure the following parameters before stoppering the vials. Avg. Product Temp Spec: xx ± x C Vacuum Spec: xx ± xx µbar Condenser Temp. Spec: - xx C C µbar C Stop the cycle and stopper the vials as per SOP No.. Time of Stoppering: h. 9 Chamber vacuum released sterile air at h. Instruct production department to unload the vials after breaking the vacuum air. xx h xx min ± x h Done / Checked By x ± x h DEVIATIONS DURING LYOPHILIZATION (if any) :

23 Department Name Filling Building # Page No Page 23 of 27 Activity : ALUMINUM CAPS PROCESSING Ref SOP No : 1. Verify that QC approved Aluminum Caps of correct colour have been taken for decartoning. 2. Remove the outer package and transfer the inner plastic bag to the sterilizer loading area. 3. The caps can be processed in either of the two ways: A) Sterilization in Autoclave X and drying in dry heat sterilizer (DHS) XX; B) Sterilization and drying in Autoclave Y. If option A is selected, then transfer the caps into clean SS trays, load into the autoclave as per validated loading pattern and Sterilize it at XXX C to XXX C for xx minutes. Pattern No 1 II No of Caps/trays 4. After sterilization, transfer the trays containing the Aluminium caps from the autoclave to the DHS via clean room side for drying at xxx C for xx mins Normal variation x C to + x C 5. If option B is selected then process the caps at xxx C ± x C for xx minutes in the autoclave. 5. Write /verify Product, B.No., Charge No and date on the sterilizer thermograph / printout (for Option A only) sign it and attach it to this BMR A) Aluminum Cap input: 13 mm, Colour Done 1) Unprocessed b/f: B.No 5) Option of Process No A = B =1+ 4 Description of Activity 2) Processed b/f: B.No 3) Fresh quantity issued 4) Fresh used from issued Nos Nos Nos Nos Unprocessed quantity from this batch (18) (3-4) Nos 6) Taken for Sterility = 9 (For 1 / 2 batch/es) B) Loaded in Autoclave No. ################ Charge No. Load Pattern No Prog No. Checked C) Aluminum Cap Drying at xxx C in DHS No: ########### Charge No. xxx C Achieved at xxx C Held till h h Remarks:-.

24 Department Name Filling Building # Page No Page 24 of 27 Activity : SEALING OF VIALS Ref SOP No : Lyophilizer Unloading: 1. After the lyophilization operator on duty has informed you about completion of lyophilization cycle, open the door of the Lyophilizer &unload the trays containing the lyophilized vaccine 2. Clean and Sterilize/disinfect the lyophilizer. Record the same in the BMR of the batch to be loaded. Sealing Operation: 1. Carry out sealing operation on the vials unloaded from the Lyophilizer. 2. The trays containing the good sealed vials should be transferred to visual inspection department through the material transfer hatch. 3. The sealing rejection should be loaded in autoclave and heated at xxx ºC (xx to xxx o C) for x minutes and then unloaded from the autoclave from the washing room side. Unloading & line Clearance: Rejection in Lyo Sensor (14) Vials Rejection & inactivation details Empty vial (15A) Bad seal (15B) Approx. Vial for sealing (22)-(14) = (H) Description of Activity Sealing machine used XXXXXX XXXXXX Autoclave No: Breakage (15C) Vial, Stopper Rej 15A to 15C =(15D) Started (h) Charge No: Cap rej (15E) Sealing Completed (h) Processed Caps (17) Done By Checked nos nos nos nos nos nos Approx No of Vials Handed Over To Visual Inspection Department H-15D= Trays Vials Vials Received screening: Name: : (for Screening Dept)

25 Department Name Filling Building # Page No Page 25 of 27 Activity: MATERIAL RECONCILIATION RECORD No Description Vial Stopper Caps 1 Bal. Unprocessed Material b/f (18) Quantity Prod / Batch No 2 Bal. Processed Material b/f (19) Quantity Prod / Batch No 3 Fresh Material Issued Quantity 4 Quantity used from Fresh material Res. Doc No. 5 Option for washing/sterilizing [A: 1+2+4, B: 1+4] A / B A / B A / B 6 Total Quantity for Washing or Transfer based on (5) 7 Sampled for Adequacy of Washing XX X X 8 Rejected during Washing or Transfer X X 8A Rejection in % [(8/6) x 100] Limit: 2% 9 Sterilized [6-(7+8)] 10 Quantity for Filling/Sealing (If 5: A, 10=9) (If 5: B, 10=9+2) 11 Sampled- Post Sterilization x x 12 Rejection- Filling stage x 13 Sampled- Filling stage xx xx xx 14 Rejection: Lyophilization stage x 15 Rejection: Sealing stage 16 Post Sterilization Sample and Rejection (Sum 11 to 15) 17 Bal. Processed Material Quantity c/f Prod/Batch No or ICN 18 Bal. Unprocessed Material Quantity [3-4] c/f Prod/Batch No or ICN 19 Quantity of vials for visual inspection 20 Variance* In No: [(1+2+3)-( )] In percent: [(In no)/(10-17)] x 100, 21 Consumption (1+2+3)-(17+18) *Permissible variance ± X % Vial and Cap, ± X % Stoppers

26 Department Name Filling Building # Page No Page 26 of 27 Activity: BULK RECONCILIATION RECORD After the sealing activity is over, reconciliation on the basis of final bulk should be done to determine the percentage yield for the batch. No Description (A) (B) 22 Quantity of vials Loaded in Lyophilizer Vials 23 Volume per Vial as declared Bulk Mfg Dept X ml 24 Batch Vol. dispensed Bulk Mfg Dept L 25 Fill Volume X ml 26 Batch Vol. rechecked Filling Dept L 27 Post Clarification Yield [26-(29/1000)] L 28 Theoretical yield [(26) x 1000]/ (25) Vials 29 Blending & Filtration residue (29A=26-27) 29B=29A/25 ml Vials 30 Sample in Liquid Form [Filling stage] XX ml 31 Excess Volume Balance in Tank after filling ml 32 Total Liq Samples /Losses [32A= ] 32B =32A/ 25 ml Vials 33 Total Loss/Samples as vials (32B+16) Vials 34 Expected Yield 28-33B Vials 35 Final yield [(19) / (28B) x 100] (not less than XX%) % 36 Percentage Reconciliation [(19) / (34B) x 100] % Stage: Post Clarific n Filling Lyophiliz n and Sealing Total Calc x B / 28 [(28-29B)-22]/(28- (22-19) / 22 Sum of all 29B) Norm (NMT) x % x % x % x % Actual: Remarks: DEVIATION: Yes / No. If yes, Report date/s:

27 Department Name Filling Building # Page No Page 27 of MANUFACTURING DEPARTMENT : BMR CERTIFICATION The contents of this Document have been checked and verified me. The information contained herein is complete and true to the best of my Knowledge. Deviations if any are reported. Hence submitted to Quality Assurance department. Signature of Production Officer : of Completion of Submission : : 02. QUALITY ASSURANCE DEPARTMENT : I here certify that, this batch record is reviewed me, to ensure that the above mentioned batch process has been carried out according to the Authorized Master formula and processing instructions. All operational steps have been scrutinized and approved according to the checklist (attached ) and have been found to be complete. Signature of Quality Assurance Review Officer : of Receipt of Approval : :

Clinic Washer-Disinfectors. Washer-Disinfector Line

Clinic Washer-Disinfectors. Washer-Disinfector Line Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative

More information

All Processes Dr. Paul Ruffieux Consultant

All Processes Dr. Paul Ruffieux Consultant PSI-L Isolator Platform All Processes Dr. Paul Ruffieux Consultant 1 Requirements Is it possible to have one Isolator for Filling under aseptic conditions (Grade A) Use of isolator technology in ISO8 room

More information

Guidance on safe use of Autoclaves

Guidance on safe use of Autoclaves Safety Office Reviewed: Dec 2013 Reviewed: DD Month Year Guidance on safe use of Autoclaves 1. Hazards & Uses There are several different types of hazard associated with the use of autoclaves. The main

More information

How To Store An Acam2000 Vaccine

How To Store An Acam2000 Vaccine ACAM2000 Smallpox (Vaccinia) Vaccine, Live Deployment Guidance - Acambis Inc. Revision: October 2008 Information contained in this guidance will also be available through Acambis, in the event that questions,

More information

LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de

LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible

More information

Environmental Monitoring

Environmental Monitoring Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is

More information

Solids, Volatile Dissolved and Fixed Dissolved

Solids, Volatile Dissolved and Fixed Dissolved , 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206

More information

German engineering under high pressure

German engineering under high pressure German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves

More information

Cleanroom. For. Sterile Manufacturing Facilities

Cleanroom. For. Sterile Manufacturing Facilities Cleanroom For Sterile Manufacturing Facilities Praphon Angtrakool Food and Drug Administration 1 WHO TRS No. 823 Annex 1, 1992 (1) General 17.1 The production of sterile preparations should be carried

More information

Assembly and Installation Procedures

Assembly and Installation Procedures Assembly and Installation Procedures for Pall Pharmaceutical Grade Capsule Assemblies 1. Introduction The following procedures must be followed for the installation of Pall pharmaceutical grade capsule

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 032-2 8 January 2010 RECOMMENDATION GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Freezers - Ultrafreezers. Platilab & Irilab Series

Freezers - Ultrafreezers. Platilab & Irilab Series Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store

More information

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd. Jabiru Service Bulletin Number A3 Fuel System Cleaning Note on Revision 2. Revision 2 of this Service Bulletin updates the cleaning procedure using knowledge that has been gained by Jabiru. This revision

More information

Steam Sterilization Cycles for Lab Applications

Steam Sterilization Cycles for Lab Applications Steam Sterilization Cycles for Lab Applications Presented by Gary Butler STERIS Life Sciences August 2009 Early Steam Sterilizers Koch Upright Sterilizer First Pressurized Sterilizer First built by Pasteur-Chamberlain

More information

Sterilizers with extra class

Sterilizers with extra class Sterilizers with extra class ClassB Ready for the future The European standard EN 13060 specifies the performance requirements and test methods for small steam sterilizers. These are used for hygiene and

More information

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA SOP#: 1005.7 Date Issued: 10/98 Date Revised: 2/16 Page 1 of 7 TITLE: SCOPE: RESPONSIBILITY: PURPOSE: Animal Care

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

Food Processing Industry FDF 98. Dairy Competency Units NATIONAL FOOD INDUSTRY TRAINING COUNCIL. Qualification. Certificate I in Food Processing

Food Processing Industry FDF 98. Dairy Competency Units NATIONAL FOOD INDUSTRY TRAINING COUNCIL. Qualification. Certificate I in Food Processing Food Processing Industry Dairy Competency Units NATIONAL FOOD INDUSTRY TRAINING COUNCIL Qualification Certificate III in Food Processing Certificate II in Food Processing Certificate I in Food Processing

More information

LyoBeta. R+D Freeze-Dryers

LyoBeta. R+D Freeze-Dryers LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that

More information

Fact Sheet on Steam Sterilizers at Stanford University

Fact Sheet on Steam Sterilizers at Stanford University Fact Sheet on Steam Sterilizers at Stanford University By: Environmental Quality and Water Efficiency Group, Stanford University; December 2013 Jennifer Fitch, Marty Laporte, Julia Nussbaum, Adam Kern,

More information

Case Study Neubau einer Parenteralia Fabrik 3. GMP-Forum, Kirchzarten 28. September 2012, Basel. Philip Schneider, F.

Case Study Neubau einer Parenteralia Fabrik 3. GMP-Forum, Kirchzarten 28. September 2012, Basel. Philip Schneider, F. 3. GMP-Forum, Kirchzarten 28. September 2012, Basel Philip Schneider, F. Hoffmann-La Roche Content Introduction Decontamination cycle Set-up and change over Aseptic connections Glove handling and testing

More information

DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION

DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION 1 US FDA Form 483: A Case Study DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION DEVELOPED BY FRAN RABE 2 Introduction This case study is intended to extract portions of information

More information

Heat Transfer. Condensation. Revaporization

Heat Transfer. Condensation. Revaporization Objectives Wrapping a Towel Around the Problem of Wet Packs Identify causes of wet packs in steam sterilization Review suggested documentation that can assist in solving wet pack problems Why are Wet Packs

More information

SunMor SM-V30 Solar Water Heater Installation Manual

SunMor SM-V30 Solar Water Heater Installation Manual SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning

More information

Astellas Ireland Company Ltd. (Kerry Plant) Ampoule Inspection Machine. Eoin O Sullivan 5th June 2014

Astellas Ireland Company Ltd. (Kerry Plant) Ampoule Inspection Machine. Eoin O Sullivan 5th June 2014 Astellas Ireland Company Ltd. (Kerry Plant) Ampoule Inspection Machine Eoin O Sullivan 5th June 2014 Facility History Location. AICL-Dublin Plant AICL-Kerry Plant AICL-Kerry Plant Establishment September

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption. THE EXPRESS STILL This still represents the next generation in home distillation equipment. It eliminates the problem of having to spend all day processing a 25 litre wash. Taking 1 hour to heat up, then

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

Removing Moisture within Large Double Glazed Windows

Removing Moisture within Large Double Glazed Windows Removing Moisture within Large Double Glazed Windows Copyright: Max Cottrell www.mcottrell.co.uk This article gives the reasons and a method of removing accumulated moisture from double glazed windows,

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

Washing. Sterilising. Filling. Closing. Inspecting. Labelling

Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing Page 4/5 Sterilising Page 6/7 Filling Page 8/9, 10/11 Closing Page 8/9, 10/11 Inspecting Page 12/13 Labelling Page 14/15 Syringe processing

More information

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use Please post or circulate Fact heet nvironment, ealth and afety Information for the Berkeley Campus No. 33 Revised 04/04/11 afe and ffective Use of Autoclaves Autoclaves are easy to use but can pose a safety

More information

Sterilization methods and equipment Lab 1-2

Sterilization methods and equipment Lab 1-2 Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization

More information

Overcoming Challenges in the Manufacturing of Pre-Filled Syringes. Farvea, a new comer in the PFS world PFS Tech 2016. June 2016 pharma@fareva.

Overcoming Challenges in the Manufacturing of Pre-Filled Syringes. Farvea, a new comer in the PFS world PFS Tech 2016. June 2016 pharma@fareva. Overcoming Challenges in the Manufacturing of Pre-Filled Syringes Farvea, a new comer in the PFS world PFS Tech 2016 June 2016 pharma@fareva.com Our presence around the world 11 countries 35 sites 12

More information

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No. 1203 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No. 1203 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS POLYVINYL ALCOHOL Prepared at the 68 th JECFA (2007) and published in FAO JECFA Monographs 4 (2007), superseding specifications prepared at the 63 rd JECFA (2004) and published in the Combined Compendium

More information

Microwave Meter. Instruction Manual

Microwave Meter. Instruction Manual Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

Questionnaire Pure Media Systems

Questionnaire Pure Media Systems 1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold

More information

HSL-VS Vials + Syringes

HSL-VS Vials + Syringes HSL-VS Vials + Syringes High speed filling and closing machines for combined processing of vials and single-use syringes. 100% weight control / Liquid filling from 0.1 250 ml. / Powder filling from 2 1,500

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Body Art Facility Infection Prevention And Control Plan Guideline

Body Art Facility Infection Prevention And Control Plan Guideline Body Art Facility Infection Prevention And Control Plan Guideline In accordance with the California Health and Safety Code, Section 119313, a body art facility shall maintain and follow a written Infection

More information

B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS

B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS TECHNICAL INFORMATION B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS ILFORD MULTIGRADE developer MULTIGRADE is a rapid liquid concentrate dimezone-s/hydroquinone

More information

FILLING, STOPPERING AND CAPPING MACHINES

FILLING, STOPPERING AND CAPPING MACHINES FILLING, STOPPERING AND CAPPING MACHINES FILLING, STOPPERING AND CAPPING MACHINES The modern design of STERILINE filling, stoppering and capping machines takes into consideration the newest requirements

More information

Guide to Master Formulae WHO/FWC/IVB/QSS/VQR

Guide to Master Formulae WHO/FWC/IVB/QSS/VQR WHO/FWC/IVB/QSS/VQR 2011 This guidance document GUIDE TO MASTER FORMULAE is one of a series developed by WHO/FWC/IVB Quality, Safety & Standards team upon request from the manufacturers members of the

More information

MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION

MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION Autoclave SERENA/Manual for technician/rev.02/23.05.14 Pagina 1 SUMMARY 1. ACCESS

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

Butt Fusion Welding of HDPE Pipes Work Procedure

Butt Fusion Welding of HDPE Pipes Work Procedure Butt Fusion Welding of HDPE Pipes Work Procedure A pipeline is as good as its weakest point. Accordingly it is not only important that quality pipes and components are used in a piping system, but also

More information

Protocol Micro Lab. K:\Microlab_protocols\Protocols_active\03 Instrument manuals\ml03_001_001 DGGE.doc. Preparation of gels

Protocol Micro Lab. K:\Microlab_protocols\Protocols_active\03 Instrument manuals\ml03_001_001 DGGE.doc. Preparation of gels Preparation of gels Cautions: Wear gloves all times when handling acryl amide and form amide solutions and all work with acryl amide and form amide has to be done in a flow hood. Acryl amide is very toxic.

More information

Needlestick Injury Prevention Assessment Tool

Needlestick Injury Prevention Assessment Tool Needlestick Injury Prevention Assessment Tool WHO PROJECT TO PREVENT NEEDLESTICK INJURY and HIV TRANSMISSION AMONG HEALTHCARE WORKERS March 2005 Combined tool for assessing the safety of injections, suturing,

More information

MOISTURE (Karl Fischer, Buffered)

MOISTURE (Karl Fischer, Buffered) MOIST.03-1 MOISTURE (Karl Fischer, Buffered) PRINCIPLE SCOPE The sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized Karl Fischer reagent. The titration

More information

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line Vertical and Benchtop Autoclaves for Life Sciences Laboratory Line Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide

More information

2A.1 Features of Chiller Control Components... 104. 2A.3 Chilled-Water Supply Temperature Control... 107. 2A.4 Cooling-Water Supply Control...

2A.1 Features of Chiller Control Components... 104. 2A.3 Chilled-Water Supply Temperature Control... 107. 2A.4 Cooling-Water Supply Control... Appendix 2A: Chiller Control Principles... 104 2A.1 Features of Chiller Control Components... 104 2A.2 Start-up and Shutdown... 105 2A.2.1 Start-up...105 2A.2.2 Shutdown...106 2A.3 Chilled-Water Supply

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE! PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE! 1. Read all instructions carefully before using the machine. 2. Do not touch hot surfaces. Use handles or knobs. The lid and

More information

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2 0932 Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46 1 Index 1 Index... 2 2 Description of the Inputs / Outputs... 4 2.1 Inputs / Module OMRON ID201 / ID211...4 2.2 Outputs / Module OMRON OC211...5

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Particle Monitoring Requirements in Pharmaceutical Cleanrooms Particle Monitoring Requirements in Pharmaceutical Cleanrooms All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations. Pharmaceutical manufacturers

More information

Instructions for Use. Components of the GENOTROPIN PEN 12

Instructions for Use. Components of the GENOTROPIN PEN 12 Instructions for Use Important Note Please read these instructions completely before using the GENOTROPIN PEN 12. If there is anything you do not understand or cannot do, call the toll-free number listed

More information

Manual 20.2.2015 v1 Page 1 of 17. Manual. Laboratory autoclave

Manual 20.2.2015 v1 Page 1 of 17. Manual. Laboratory autoclave Manual 20.2.2015 v1 Page 1 of 17 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

OI Inventory Monitor Units

OI Inventory Monitor Units OI Inventory Monitor Units Bulletin Number: BF6-600 Effective: 9/14/07 Write Down Your Serial Numbers Here For Future Reference: We are committed to a continuing program of product improvement. Specifications,

More information

Standard Hydraulic Piping Flushing Procedure

Standard Hydraulic Piping Flushing Procedure Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,

More information

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin. About Calcium Reactors: A calcium reactor is a device that dissolves calcium carbonate by using co2 gas to create an acidic condition within the reaction chamber. A circulation pump is used to move the

More information

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172 Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING

More information

AUTOCLAVE STEAM STERILIZERS

AUTOCLAVE STEAM STERILIZERS AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option

More information

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1. Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the

More information

Climate chamber with illumination

Climate chamber with illumination KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural

More information

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer 450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon

More information

TROUBLESHOOTING FLOW CHART

TROUBLESHOOTING FLOW CHART TROUBLESHOOTING FLOW CHART Revised and updated on January 16, 2003, by Tony Leger and Automation Lab Technology. FACScan(FC)\FACSort(FST) FACScalibur (FCB) Fluidics/Pneumatics troubleshooting guide DCM

More information

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam

More information

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS Dr. Abhay Kumar Sahay, AGM(CC OS) Bijay Manjul, AGM( Operation) Kahalgaon Boiler has three inputs Steam generator 1. WATER 2. COAL 3. AIR Burner Air preheater

More information

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure 3M Purification Product brochure LifeASSURE PFS Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters LifeASSURE PFS Series is new name for CUNO Microfl uor II Hydrophobic PTFE fi lter medium

More information

ME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

ME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS ME 315 - Heat Transfer Laboratory Nomenclature Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS A heat exchange area, m 2 C max maximum specific heat rate, J/(s

More information

INSTRUCTIONS 56-1190-98. Edition AC

INSTRUCTIONS 56-1190-98. Edition AC Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography

More information

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory

More information

Dewchecker 2.0. Operating instructions. messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren

Dewchecker 2.0. Operating instructions. messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren Operating instructions Dewchecker 2.0 messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren 1. Application The Dewchecker is suitable for dewpoint measuring of

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use. Large Facility Fire Safety Checklists and Logs This package contains checklists to ensure that all fire and life safety equipment are properly inspected. There are also logs on which to record the inspections

More information

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified: STEAM STERILIZERS DLOV & DLOM series DE LAMA s Quality Management System is certified: more than fifty years of experience in sterilization UNI EN ISO 9001:2000 - Cert. n 0351 UNI EN ISO 13485 - Cert.

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

LifeASSURE PFS Series Filter Cartridge Integrity Testing

LifeASSURE PFS Series Filter Cartridge Integrity Testing LifeASSURE PFS Series Filter Cartridge Integrity Testing Introduction Integrity testing is the end user s method of confirming the structural integrity of a membrane filter before and after use. It is

More information

Vacuum Tube Solar Water heater Non-pressure. User manual

Vacuum Tube Solar Water heater Non-pressure. User manual Vacuum Tube Solar Water heater Non-pressure User manual Please read this manual carefully before beginning installation Specification Tubes 12 --- 30 58X1800 Nominal volume tank capacity 100L --- 300L

More information

Experiment 1: Colligative Properties

Experiment 1: Colligative Properties Experiment 1: Colligative Properties Determination of the Molar Mass of a Compound by Freezing Point Depression. Objective: The objective of this experiment is to determine the molar mass of an unknown

More information

High Capacity Hot Air Dryer

High Capacity Hot Air Dryer High Capacity Hot Air Dryer MADE IN AUSTRIA autumn 2015 www.zimmer-austria.com page 1 Hot air dryer type: Compact HC The modular construction of the high efficiency and powerful hot air nozzle dryer is

More information

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical

More information

Laboratory- and sterilisation equipment HMC EUROPE

Laboratory- and sterilisation equipment HMC EUROPE Laboratory- and sterilisation equipment HMC EUROPE PROFILE HMC EUROPE Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges,

More information

Top 10 considerations when validating an autoclave

Top 10 considerations when validating an autoclave Top 10 considerations when validating an autoclave Validating an autoclave is a daunting and time-consuming task. This white paper details the tricks, tips and traps to such a validation project from how

More information

Horizontal Steam Sterilizers. Healthcare Line. Since

Horizontal Steam Sterilizers. Healthcare Line. Since Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,

More information

Trace Dissolved Oxygen Sensor

Trace Dissolved Oxygen Sensor Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION

More information

How Tight is a Syringe? PDA: A Global. CCI Case Studies From. Association. Development and Manufacturing. Dr. Derek Duncan Director Product Line

How Tight is a Syringe? PDA: A Global. CCI Case Studies From. Association. Development and Manufacturing. Dr. Derek Duncan Director Product Line How Tight is a Syringe? PDA: A Global CCI Case Studies From Association Development and Manufacturing Dr. Derek Duncan Director Product Line Presentation Outline Setting up syringe CCI studies using laser-based

More information

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available:

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available: Cyclone Models Available: HMHF DIRECT DRIVE BELT DRIVE INITIAL PARTICLE SIZE: MATERIALS MILLABLE: PARTICLE SIZE GENERATED: SAMPLE FEED INTO THE MILL: SAMPLE MILL GRINDING CHAMBER: GRINDING RATE AND COLLECTION

More information

Narlin B. Beaty, Ph.D. Page 1 Chesapeake Biological Laboratories, Inc.

Narlin B. Beaty, Ph.D. Page 1 Chesapeake Biological Laboratories, Inc. Incremental Addition of Parenteral Capacity Case Study for a Lyophilizer Filling parenterals is capital intensive, with large, fixed ongoing maintenance fees to support continuous operations. There is

More information

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs WHITE PAPER 7004 How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs By John Boehm Business Unit Manager Colder Products Company Today s

More information

Thermo Scientific Heratherm Microbiological Incubators. Safe,

Thermo Scientific Heratherm Microbiological Incubators. Safe, Thermo Scientific Heratherm Microbiological Incubators Safe, easy and efficient Thermo Scientific Heratherm Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new

More information

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer

More information

How to Prepare Powdered Infant Formula in Care Settings

How to Prepare Powdered Infant Formula in Care Settings How to Prepare Powdered Infant Formula in Care Settings This booklet contains new information to help you prepare powdered infant formula for bottle-feeding and cup-feeding as safely as possible. Powdered

More information