KINETICO ULTRAVIOLET WATER PURIFICATION SYSTEMS
|
|
|
- Merry Jean Brown
- 9 years ago
- Views:
Transcription
1 Owners Manual KINETICO ULTRAVIOLET WATER PURIFICATION SYSTEMS MODEL: KUV 1200x Certified to IEC PUBLICATION EDITION 4 th
2 OWNERS MANUAL Copyright Kinetico Incorporated 2009 All rights reserved. No part of this document may be photocopied, reproduced, transmitted or translated to another language without the prior written consent of Kinetico Incorporated. Crossfire Technology is a registered trademark of UV Pure Technologies Inc. Publication Number: Third Edition, November V versions of the product conforms to UL E:04& certified to CAN/CSA-E /4E:03 (by Intertek) V versions of the product meet IEC Edition 4 and CE Notice THANK YOU for purchasing a Kinetico UV water purification system Model KUV 1200x. This UV system is engineered to provide effective UV dosage rates for the inactivation of pathogens, including: viruses bacteria cryptosporidium giardia legionella E. coli Total coliforms To be effective, the system must be installed in applications that meet minimum pre-treatment specifications as set out below. The Kinetico KUV 1200x UV system is NSF/ANSI Standard 55 Class A certified. Please read the complete manual before installing or operating. Retain this manual and the purchase receipt for the unit. Rev. 02/2015 Page 2 Product No
3 1. About the Kinetico KUV 1200x UV System Kinetico KUV 1200x UV water purification systems incorporate patented Crossfire Technology. Patented in US 6,707,048, Australia 2,002,333,084, Mexico Patent Pending in Canada, Japan, UK, Europe & Eurasia Patents are owned by UV Pure Technologies Inc. and used under license by Kinetico Incorporated. Revolutionary Crossfire Technology is self-monitoring and engineered to be failsafe. Crossfire Technology incorporates twin lamps mounted in air, dual smart sensors, elliptical reflectors and an optional failsafe solenoid valve. Crossfire Technology incorporates two proprietary high-output UV lamps, within elliptical reflectors, that target pathogens with radiation from 360º, to reduce UV shadowing and provide microbiologically safe drinking water. The Kinetico KUV 1200x has dual smart UV sensors, that will not foul like conventional UV systems. The lamps are fan-cooled and maintain consistent levels of UV output for effective pathogen deactivation in a broad range of air and water temperatures. Alarms and an optional automatic shut-off solenoid valve are engineered to ensure failsafe operation. Changing lamps in the Kinetico KUV 1200x is as simple as opening the front of the system. There is no draining required, no disassembly and no risk of quartz breakage. The UV lamps require replacement after 12 months of operation; the system will provide a warning when it is time to change lamps. Each system is shipped with a Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device (SPD) that has been certified to the UL 1449 standard by an NRTL/C and includes integral Over/Under Voltage shutoff protection. This will protect the system from most power surges, spikes and brown outs. Rev. 02/2015 Page 3 Product No
4 1. Installation and Instruction Manual Installation Instructions... 5 Before Beginning Installation... 5 Water Conditions - Pre-treatment Parameters... 5 Safety Information... 6 Parts Included... 6 Other Materials Needed... 6 Tools Needed... 7 Location (on a wall)... 7 Time Required... 7 Assembling the Unit... 8 Connecting the Pipes... 8 Parallel Installation...12 Plugging in the UV...13 Flushing Instructions Operating Instructions Starting the KUV 1200x...17 Supplied Surge Protector...18 Shutting Down the KUV 1200x and Seasonal Use...18 Disinfecting the Plumbing Menu and Troubleshooting Maintenance Replacing and Cleaning UV Lamps...25 Draining the Unit...27 Cleaning the Unit...28 Determining the Need for Cleaning...28 In-place Cleaning...29 Disassembling the Unit...30 Removing and Cleaning the Quartz Sleeve...31 Reassembling the Unit...32 Replacement Parts Service Record Sheet Limited Warranty Rev. 02/2015 Page 4 Product No
5 2. Installation Instructions Before Beginning Installation Water Conditions - Pre-treatment Parameters Note: it is very important that the Kinetico KUV 1200x is installed in conditions that meet the minimum specifications for pre-treatment. Please review the following pre-treatment parameters prior to installation. Some of the specifications are technical in nature; If any specifications are of concern or unclear, please contact your Kinetico dealer. IMPORTANT: IF THE KINETICO KUV 1200x SYSTEM IS INSTALLED IN CONDITIONS THAT DO NOT MEET THE SPECIFICATIONS, IT MAY VOID THE MANUFACTURER S WARRANTY. Water Parameters for Treating Drinking Water: The minimum water requirements for operating the Kinetico KUV 1200x are: UV Transmittance (UVT) greater than 75 percent transmission of ultraviolet light. (If there is color in the water, the UV transmittance may fall below 75 and the system will not provide the necessary UV dose for safe drinking water.) It is recommended the water be tested for UV transmittance in any applications using cisterns, surface water or ground water under the influence of surface water. Level of turbidity - or cloudiness - of less than or equal to 1 NTU (nephelometric turbidity unit). A 5 micron sediment filter is recommended before the unit to reduce turbidity. (The presence of a filter will also simplify disinfection of plumbing see Disinfecting the Plumbing. For surface waters, 5 micron prefiltration is recommended.) Hardness Hardness must be less than 7 grains (120 mg/l) Total Iron Total iron must be less than 0.3 ppm (0.3 mg/l) Water Treatment Capacity: The water treatment range for the Kinetico KUV 1200x is 0 to 12 U.S. gallons per minute (or 0 45 liters per minute) max, with a working pressure of 10 to 100 psig (or 69 to 690 kpa). The Kinetico KUV 1200x includes a flow regulating device that will limit the flow rate. Warning: Removal of this device may allow the water flow to exceed the validated performance of the system which therefore may not provide the necessary UV dose to inactivate all pathogens. Removal of the Flow Restrictor installed by the Manufacturer will void the Manufacturer s Warranty. Temperature Requirements: When the unit is installed, the ambient temperature should be between 34º to104 F (1 C to 40 C). If the temperature drops below freezing, drain the unit completely to prevent damage (see Draining Instructions). The acceptable water temperature range is 34ºF to104 F (1ºC to 40 C). Energy Requirements: Rev. 02/2015 Page 5 Product No
6 There are two standard operating voltages for the UV unit. The unit may be 115 VAC, 60 Hz or VAC, 50 Hz. Please refer to the power input label located near the power cord entry of the unit. See Figure 1B. The KUV 1200x must be connected to the supplied Transient Voltage Suppressor (TVSS)/Surge Protective Device (SPD) that is plugged into a grounded power outlet. Failure to plug the Kinetico KUV 1200x into the supplied power conditioner may void the Manufacturer s Warranty. Safety Information WARNING: Potential Shock Hazard Use only a grounded electrical outlet when connecting the supplied power conditioner to a power source. If you do not know whether the outlet is grounded, check with a qualified electrician. Do not plug in the Kinetico KUV 1200x if water has been spilled on the exterior surface of the system. UV WARNING: Ultraviolet Light Hazard The lamps in the UV system emit ultraviolet (UV) light that can cause permanent damage to the skin & eyes. Never look at the lamp when it is operating. Do not plug the KUV 1200x in unless it is properly secured to a wall (see Installation Instructions) and the front panel and ballast enclosure are secure. Do not open the front panel or perform any service unless the KUV 1200x has been unplugged. Never look into the unit or place any exposed skin into the illuminated areas when it is operating. Do not operate a KUV 1200x that has been damaged or missing any components or safety devices. Parts Included Note that service to the unit does not require the removal of the side aluminum panels or aluminum endplates, and they must remain assembled. The UV unit is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the UV unit. Kinetico KUV 1200x UV water purification system, complete with integral wall brackets Instruction manual Power cord (located within packaging) Ultraviolet lamps (two) installed in the KUV 1200x Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device (SPD) Other Materials Needed The UV requires four # 12 to 1/4 diameter fasteners (not provided) to mount to a wall. It also requires two female NPT fittings for the manifold connections, and two 1 male NPT connections if the optional automatic shut-off solenoid valve is installed with the KUV 1200x. These fittings, pipe insulation, and any piping Rev. 02/2015 Page 6 Product No
7 compatible with the plumbing should be on hand before you begin installation. See Figure 1B and make a list of all necessary components including solder, paste and thread sealant. By-pass piping and valves that isolate the unit are optional, (but recommended) as is a drain valve for draining the unit. Using a union or a flexible stainless hose at the top and bottom port of the unit is recommended to allow easier maintenance of the unit. Pipe insulation should be wrapped around any overhead piping to prevent condensation from dripping back onto the unit. Tools Needed Pipe cutter, torch, wrench and other typical plumbing tools for modifying piping Slotted screwdriver Do not operate a Kinetico KUV 1200x that has been damaged or that is missing any component. If a part is missing, contact your Kinetico dealer. The installation (see Figures 1A through 1F) should be done in compliance with all applicable federal, state/provincial, and local regulations. Failure to install the KUV 1200x properly may result in property damage (leaks/flooding) or personal injury (electrical shock) and will void the Manufacturer s Warranty. The KUV 1200x is intended only for indoor use in a dry location. Should these minimum installation recommendations not be met, the system will not operate effectively. Location (on a wall) The KUV 1200x must be positioned vertically on a wall (The performance of the system will be adversely affected if mounted horizontally.) See Figure 1A for clearances. The KUV 1200x should be installed downstream of (after) any pre-treatment devices such as filters, water softeners and any pressure tanks. However, it must be installed upstream of (before) any branches in the piping so that all the water is disinfected before splitting and distributing throughout the home or building. If the plumbing system has a grounding lug or strap, this should also be upstream from the KUV 1200x, and any shut-off valve or filters. If grounding or plumbing of the Kinetico KUV 1200x system is in question, please consult your local electrical inspector. Time Required Please note that full installation of the UV requires shutting off the main water supply for up to several hours. If disinfection is necessary, all pipes must be treated and flushed. Once the KUV 1200x is plugged in and turned on, the new UV lamps may take from a few moments to several hours to reach full power. Summary of Installation: Rev. 02/2015 Page 7 Product No
8 Unpack and attach the KUV 1200x to a wall Connect inlet and outlet manifolds to plumbing Install optional Shutoff solenoid valve, if included Install optional by-pass plumbing Connect system power cord to supplied Transient Voltage Surge Suppressor Connect Transient Voltage Surge Suppressor to grounded power outlet Assembling the Unit Step 1: Unpack the unit, being careful to remove all packaging material. Inspect the unit for damage, particularly the quartz sleeve See Figure 4A for disassembly. Check to ensure that the rear reflector is sitting as low as it will go push down so that it rests on the bottom plate of the system. (Sometimes movement in shipping can cause the rear reflector to ride upward during transit.) Step 2: The KUV 1200x has four keyhole slots for convenient mounting all four should be used. To mount the system, use the template, included, to position the two top holes. The unit should be secured vertically to a solid wall large enough to cover the complete backside of the unit See Figure 1D. Do not install the system horizontally. Remove the top and bottom covers of the unit to make the mounting holes accessible. Connecting the Pipes We recommend that a qualified Kinetico dealer or licensed plumber perform the water connections for your UV system. Water must flow into the inlet at the bottom of the KUV 1200x. The outlet is located at the top of the unit. Install the optional shutoff solenoid valve just upstream (before) from the KUV 1200x, if included. Step 1: Shut off the water supply. Caution: Always turn off the water supply before modifying or disconnecting any piping. Always open a faucet after shutting off the water supply to relieve water pressure and ensure that the water has been completely shut off. Step 2: If you have decided to install an optional by-pass line and drain valve, you may begin to install these fittings at this point. See Figure 1B for more information on how to connect optional by-pass piping and drain valve. Step 3: Connect the optional shut-off solenoid valve (if included) to the plumbing just upstream from (before) the KUV 1200x. Note: the solenoid valve ensures that should the system fail, due to power loss, color in the water or low UV lamp output, the KUV 1200x has a failsafe mode and will shut down the flow of water to your taps. The direction of flow through the shut-off valve is important verify the flow direction with the label on the valve. Caution: over tightening a metal fitting into the valve may cause it to crack. Do not over tighten. Keep the coil of the valve pointing upward (to prevent water from dripping on it). Water will not flow backward through the valve. See Figure 1C. Rev. 02/2015 Page 8 Product No
9 NSF/ANSI 55 CLASS A CERTIFIED CERTIFIE NSF/ANSI 55 CLASSE A NSF/ANSI 55 CLASSE A CERTIFICADO KUV 1200x Owners Manual 9.31" [236mm] 7.54" [191mm] 19.5" [495mm] 24.34" [618mm] WATER OUT 1" MNPT 3.46" [88mm] QUARTZ SLEEVE CLEARANCE REQUIRED TO REMOVE QUARTZ OPEN Kinetico 35.75" [908mm] 28.27" [718mm] NSF WATER IN 1" MNPT TO MOUNT USE #12 OR 1 4" DIA. SCREW (4-PLACES) 3.5" [89] 12.0" [305] Figure 1A Rev. 02/2015 Page 9 Product No
10 ON/RESET POWER OFF NSF/ANSI 55 CLASS A CERTIFIED CERTIFIE NSF/ANSI 55 CLASSE A NSF/ANSI 55 CLASSE A CERTIFICADO KUV 1200x Owners Manual PIPE INSULATION (MUST BE INSTALLED) KUV 1200x MOUNTED VERTICAL AGAINST A WALL Kinetico GROUNDED OUTLET 115VAC 50/60Hz OR VAC 50/60Hz NSF CONNECTION FOR OPTIONAL SOLENOID VALVE TRANSIENT VOLTAGE SUPPRESSOR POWER CORD ENTRY & LOCATION OF SERIAL NUMBER OPTIONAL SOLENOID VALVE (UNI-DIRECTIONAL) (TEST VALVE MONTHLY) COPPER TUBING OR EQUIVALENT (DO NOT USE PVC) MANUAL SHUTOFF VALVE OPTIONAL DRAIN VALVE OPTIONAL BY-PASS VALVES Figure 1B LEVER FOR OVERRIDE FOR NON REGULATED SITES ONLY SOLENOID VALVE (ACTS AS CHECK VALVE) FLOW FLOW AUTOMATIC POSITION Figure 1C MANUAL POSITION (FORCE OPEN) Rev. 02/2015 Page 10 Product No
11 MOUNT UNIT FLAT AGAINST WALL OR PLYWOOD WOOD TO RISE AT LEAST TO TOP OF UNIT OR WOOD TO FALL AT LEAST TO BOTTOM OF UNIT INCORRECT MOUNTING CORRECT MOUNTING Figure 1D Step 4: Connect the optional shut-off solenoid valve to the inlet piping attached to the bottom of the KUV system. The solenoid valve activation cord plugs into the right hand side of the KUV 1200x where a port is provided. The optional shut-off solenoid valve is a non-serviceable component and nothing else should be plugged into this port. Secure the cable from the valve to the wall. The solenoid valve is normally closed and must be powered to open. The valve has a manual override (a white lever located on the valve itself) that can be used to manually open the valve should you require water for service/emergency purposes. (Note: in the event of alarm and shut down, it is recommended you boil your water). In regulated sites such as municipal applications, the manual override may not conform to regulations. If so, it should not be used. For normal operation, always leave the valve in the automatic position. Caution: Do not allow solder or solder flux to fall in or on the KUV 1200x. Step 5: Connect the outflow piping to the outlet port located at the top of the unit. Do not use PVC pipe or braided hose at the outlet. During extended periods of no flow, water temperatures may exceed the softening point of PVC. Step 6: Caution: do not allow the inside of the unit to get wet. Before turning on the water supply, double check all connections and cover the top of the system with a rag or some plastic to prevent water entry. Ensure front panel is closed. Close any faucets you opened in Step 1, and then slowly turn on the water supply to check for leaks. If leaks exist, investigate the cause and repair. Caution: Do not connect the system to electrical power until the piping and unit Rev. 02/2015 Page 11 Product No
12 are free of water leaks. The optional solenoid valve may be placed into manual mode to allow water to enter the system. Switch back to automatic mode when done. Step 7: Once the system is checked for leaks, install pipe insulation on all overhead outlet piping to prevent condensation from falling onto or into the unit. Parallel Installation When more than one system is installed in parallel to increase treatment capacity (the flow is divided among systems), the systems must be installed with manual shutoff valves before and after each system. This allows one KUV 1200x to be serviced without interrupting the flow to the other(s). Another requirement is the installation of a check valve downstream (after) from the systems. This will prevent the backflow of water to a unit. See Figure 1E. TYPICAL INSTALLATION OF PARALLEL UNITS MANUAL SHUTOFF VALVE - ESSENTIAL CHECK VALVE ESSENTIAL OPTIONAL SOLENOID VALVE (RECOMMENDED) OPTIONAL 20" FILTER FILTER HOUSING OPTIONAL DRAIN MANUAL SHUTOFF VALVE - ESSENTIAL Figure 1E Rev. 02/2015 Page 12 Product No
13 ON/RESET POWER OFF NSF/ANSI 55 CLASS A CERTIFIED CERTIFIE NSF/ANSI 55 CLASSE A NSF/ANSI 55 CLASSE A CERTIFICADO ON/RESET POWER OFF NSF/ANSI 55 CLASS A CERTIFIED CERTIFIE NSF/ANSI 55 CLASSE A NSF/ANSI 55 CLASSE A CERTIFICADO KUV 1200x Owners Manual Kinetico Kinetico NSF NSF INSTALL RECEPTACLE HIGH TO KEEP END OF POWER CORD FROM FALLING INTO ANY WATER ON THE FLOOR CORRECT MOUNTING INCORRECT MOUNTING Figure 1F Locating the receptacle and TVSS Install the receptacle and TVSS in a sufficiently high location so that if the power cord is removed from the unit and drops, the end of it will not fall to the floor potentially in any water spills See Figure 1F. If this is not possible, the power cord should be secured to the wall to prevent it from falling. Plugging in the UV Step 1: Ensure that the front panel of the system is closed and that it is securely fastened to the wall. (Note: You should not open the front panel unless the system has been unplugged.) Caution: It is not recommended to operate the KUV 1200x dry. Water should be in the treatment chamber when the unit is in operation. Step 2: Plug the female end of the power cord into the power entry module located on the left side of the front panel. The power cord must be removed before the front panel can be opened, in order to prevent risk of electrical shock and exposure to UV light. See Figure 1B. Plug the male end of the power cord into the Transient Voltage Surge Suppressor supplied. Plug the Transient Voltage Surge Suppressor into a grounded electrical outlet. Flip the switch on the Transient Voltage Surge Suppressor to ON position. Rev. 02/2015 Page 13 Product No
14 Caution: Use only a grounded electrical outlet when connecting the KUV 1200x to a power source. If you do not know whether the outlet is grounded, check with a qualified electrician. If an extension cord is necessary, the cord should contain a ground and have an electrical rating no less than the rating of the unit or combined units. The piping connected to the UV unit must also be properly grounded. The installation is now complete. Important: After the unit has been operating for a few hours, shutdown (See Menu Section) and unplug the system. Then check all connections for leaks. Repeat this procedure periodically. Proceed to System Operation for further instructions and to ensure optimal performance. Flushing Instructions Flushing the system is required after installation or after any disassembly and cleaning. Flushing may also be required to remove colored water from the system. Most filters (if installed) also require flushing prior to use follow the manufacturer s recommendations if filters are installed before the system(s). The system may be flushed in two ways. It can be done manually by disassembling the unit and filling and draining the unit by hand (see Cleaning the Unit). Flushing may also be done while the system is operating. Plug in the system, open a faucet closest to it, and run the water for a minimum of 15 minutes. CIRCUIT BOARD LOOSEN SCREW TO OPEN BALLAST ENCLOSURE DOOR (DO NOT REMOVE) VIEW A TILT FORWARD THEN REMOVE SCREW AIR FILTER KNOCKOUT LOCATED HERE BLOWER HOUSING PANEL FLIPS DOWNWARD Rev. 02/2015 Page 14 Product No
15 BLOWER HOUSING PANEL Figure 1G PLUG TO J6 BLOWER CLIPS TO LATCH TO METAL HOUSING Figure 1H 3. Operating Instructions The KUV 1200x incorporates advanced Crossfire Technology, yet is simple to operate. Inspection of the quartz chamber is a simple visual inspection. The only required maintenance is the replacement of the two UV lamps every 12 months (Note: If you shut your system down for seasonal use, the lamp life will be extended.) Periodic inspections of the quartz sleeve is recommended to ensure optimal unit performance (see Determining Need for Cleaning Section). KUV 1200x System Functions LCD DISPLAY UP ARROW LEFT ARROW DOWN ARROW RED LIGHT ALARM CONDITION AMBER LIGHT WARNING CONDITION GREEN LIGHT UNIT TREATING RIGHT ARROW ALSO "ENTER" Figure 2 There is an LCD display, four push buttons and three indicating lights on the front Rev. 02/2015 Page 15 Product No
16 panel. (See Figure 2.) The push buttons allow you to navigate the menu screens on the LCD display. (See the Menu section.) LCD Display The 2 line backlit display provides status information including lifetime remaining on lamps, message history and setup options. (See the Menu Section.) Push Buttons Left Arrow press to move back to a previous menu and/or to escape from a menu choice. Up Arrow press to move up a menu in a section and also select data whether it is menu choices or numerical values. Down Arrow press to move down a menu in a section and also select data whether it is menu choices or numerical values. Right Arrow press to Enter selection or save value. Indicating Lights Positioned on the front Control Panel Green Light located in the bottom position, an illuminated green light indicates the UV is treating normally. A flashing green light means that the UV lamps have not yet reached full power or that the system is in standby mode awaiting a remote start. Amber Light located in the middle position, an amber light may indicate that the initial set-up process has begun or is an indication of a warning of some condition that should be addressed. Warnings are accompanied by a single beep with a message and troubleshooting diagnostics displayed in the LCD. Red Light located in the top position, a red light is an alarm for a condition that has significantly impacted the UV s performance. It must be addressed immediately. Alarms are accompanied with continuous beeping, with a message and troubleshooting diagnostics displayed in the LCD. Audio Alarm The KUV 1200x is equipped with an audible beeper to provide an alert to any condition that is not normal. Single Beep will sound if a warning occurs. This will be accompanied by an amber light and a message with troubleshooting diagnostics displayed in the LCD. Continuous Beeping will sound in an alarm condition. This will be accompanied by a red light and a message with troubleshooting diagnostics displayed in the LCD. Rev. 02/2015 Page 16 Product No
17 Note: The audio alarm may be disabled temporarily or permanently from the Service Menu. Starting the KUV 1200x Caution: Do not operate the system with the front carriage door or ballast enclosure door open. Do not try to open the front carriage door or ballast enclosure door when the system is operating Shut down (see Menu Section) and unplug the system before opening either the front carriage door or ballast enclosure. The KUV 1200x has a safety switch that will disable the lamp power supply if the ballast enclosure door is not completely closed. Caution: It is not recommended to operate the KUV 1200x dry. Water should be in the treatment chamber when the unit is in operation. In the event of a lack of water or if the water supply is turned off, unplug the system until the water supply is restored. In the event of a power failure, the unit will shut down automatically and the optional solenoid shut-off valve, if installed, will close, preventing water from flowing. When the power returns, the unit will automatically restart and perform a self-test. If no faults are detected, the unit will return to normal operation and the optional solenoid shut-off valve will open automatically. Note that during a brownout, the supply voltage may drop low enough to cause the unit to shut down. If the unit does not automatically restart as described above, shut down (see Menu Section) and unplug the unit, and plug it in again. This will re-boot the system, and it will re-start automatically. Step 1: Make sure the UV unit is plugged into the Transient Voltage Surge Suppressor (TVSS) that is supplied with the system, and plug TVSS into a grounded outlet to start the system. Caution: Never look into and never expose skin to the UV lamps when the unit is operating. Step 2: When the KUV 1200x is plugged in, all three Indicating Lights will illuminate, an Audible Alarm will beep and the LCD display will become active. This verifies that the Indicating Lights, the Audible Alarms and the LCD are functioning. The system will then perform a self-test. When the UV lamps are new, or when the UV lamps have been replaced and the lifetime lamp hour counter is reset, the system will enter an Initial Set-up program. During this process, the lamps will be energized and will warm up to reach full power. While this is occurring, the Green Indicator Light will flash, and the Amber Light will be illuminated. The LCD will display: INITIAL SET-UP, MAY TAKE 24 HRS. The process may, indeed, last for 24 hours. When the initial set up is complete, a solid Green indicator light will appear, and the LCD will display Unit Treating. This is the normal operating mode of the KUV 1200x. If the optional solenoid shut-off valve is installed, it will be kept open during Initial Set Up, and returned to automatic mode once the system is in normal operating conditions. During normal operation, if a power outage occurs, the system will re-start automatically within a few minutes after power is restored; an alarm will occur if Rev. 02/2015 Page 17 Product No
18 the system is not treating normally within 10 minutes of power being restored. If the UV lamps fail to energize during start-up procedures, the system will automatically retry to start the lamps 5 times before issuing an alarm. If that occurs, re-boot the system by unplugging and plugging it back in, which will cause the system to enter the re-starting procedure again. Supplied Surge Protector Installation of the supplied Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device (SPD), certified to the UL 1449 standard by an NRTL/C that includes integral Over/Under Voltage shutoff protection, is required. Kinetico s KUV water purification systems are designed to operate within normal power grid specifications (voltages and frequencies), worldwide. However, power spikes, surges and brownouts are a common occurrence in all countries. When that happens, line voltages may fluctuate outside the systems operating specifications. Installation of the supplied TVSS/SPD between the UV system and the power source will increase the likelihood of the system surviving transient events on the AC power grid. This will help to ensure uninterrupted water treatment and reduce the risk of repairs due to damage from power spikes, surges and brownouts that are not covered by the Manufacturer s Limited Warranty. Shutting Down the KUV 1200x and Seasonal Use To power down the system, press Enter when the LCD is displaying Unit Treating. Then, select Shutdown Unit from the main menu and when the message You may safely unplug your unit appears, simply unplug the KUV 1200x. If an alarm condition exists and it can not be resolved, simply unplug the system to power it down. The KUV 1200x may be left on for extended periods of time without use of water as long as the system has water in it and has not been drained. Extended periods of no water usage however, may increase chances of quartz fouling. Periodic inspections of the quartz sleeve is recommended to ensure optimal unit performance. The system may also be shut down in the case of a seasonal residence or during a vacation. If the possibility of freezing exists, the system and any filters must be drained. (See Draining the Unit.) When the system is first restarted, in spring for example, reconnect all fittings, close all valves and turn on the water supply. Plug in the UV and when operational, flush water through the system for at least 15 minutes. Caution: When the system is not operating, the optional solenoid shut-off valve, if installed, remains closed. If the solenoid valve is manually opened, or if the optional by-pass piping is used, untreated water may enter the plumbing system. Emergency use of untreated water is the only time that by-pass piping should be used. In that case, any water used for drinking should be boiled. Unplug the system if the by-pass is used. Rev. 02/2015 Page 18 Product No
19 Disinfecting the Plumbing KUV 1200x Owners Manual Disinfection of the household or building plumbing should be performed after the UV system has been installed and is operating. This procedure should also be done if the system is not functioning normally, if a by-pass has been used, or if there has been a high background bacteria count in a water sample. Disinfecting the plumbing will ensure that any potential bacteria or contaminants in the distribution system are treated prior to system use. Please note that this procedure is ineffective against protozoa that can be found in surface water or shallow wells under the influence of surface water. Under these circumstances, it is important to perform the disinfecting procedure and then operate the UV unit. This procedure does not work with sediments or heavy biofilm and encrustations, which must be removed mechanically. Sanitizing the household or facility plumbing is accomplished by adding 50 ppm chlorine from bleach for 12 hours and then flushing. This can be achieved by doing the following: Step 1: Shut down (see Menu Section) and unplug the KUV 1200x. Step 2: Shut off the water supply, and relieve the water pressure by opening a faucet. Step 3: Remove a filter (if installed) from its housing and fill the housing with bleach. Step 4: Re-mount the housing (but not the filter) and plug in the UV system to turn it on. Step 5: When the KUV 1200x is operating, turn on the water supply and run water to all faucets (hot and cold), toilets, the washing machine and other waterusing appliances the bleach must fill every inch of plumbing. A Treatment Alarm, due to low UVT, may arise after the introduction of bleach. If this occurs, use the manual override on the optional solenoid valve, if installed, to keep valve open during procedure. Return override to auto position after the disinfection process is complete. Step 6: When you detect the odor of chlorine at each spot, stop running the water and let the bleach remain in the lines for at least 12 hours. Turn off the UV system during this procedure. Step 7: After the waiting period is over, plug in the UV system. Once stable, flush every line for at least five minutes or until the odor of chlorine is gone. See local regulations for proper disposal of chlorine residual, especially in the case of discharge into a septic system. Step 8: Now that the disinfection procedure is complete, you will need to return the filter (if installed) to its housing. Shut off the water supply, relieve water pressure by opening a faucet, and return the filter to the housing. Allow a few days after a disinfection procedure before getting a sample since residual chlorine may affect the results. Rev. 02/2015 Page 19 Product No
20 Have the water tested by a local recognized testing agency prior to any water consumption. For your local water testing labs, contact your Kinetico dealer. The testing should be performed on a regular basis as required by local regulations. Caution: Do not allow chlorine to remain in the KUV 1200x for more than 12 hours. Do not operate the system during this time because heating the water in the system will increase the corrosive nature of chlorine. 4. Menu and Troubleshooting The KUV 1200x will run unattended unless an alarm occurs. If that happens, the optional solenoid shut-off valve will close, preventing water from flowing. The Green Indicator Light will go out, the Red Indicator Light will illuminate, the Audible Alarm will beep and an alarm message will be displayed on the LCD. The problem must be corrected to return the unit to normal operation. When an alarm situation occurs, navigate to the Alarm Condition Exists screen by pressing the LEFT or RIGHT arrow on the control panel several times. The audio alarm will silence as soon as any arrow is pressed. Next, press RIGHT arrow to review the LCD message to determine what alarm condition occurred. The menu will automatically bring you to Alarms and Troubleshooting section for assistance with the current condition. The Message History can also be reviewed to examine other recent events. In addition to Alarms that indicate potentially serious concerns, there are warnings that are status alerts. Warnings will not close the optional solenoid shut-off valve, if installed. If a warning is left unaddressed, a system fault could subsequently occur. In a warning condition, the audio alarm will beep once, the Amber Indicator Light will illuminate and a warning message will be displayed in the LCD. Disinfection of water will occur as long as the unit is properly maintained in accordance with the instructions set out in this manual. Operating a malfunctioning unit or defeating any system sensors may jeopardize the operation of the KUV 1200x and the safety of the water. If any system failure occurs and water enters the plumbing system without being disinfected, and if the optional solenoid shutoff valve has been placed into manual mode, or if an optional by-pass is used, any water used for drinking should be boiled. Under these circumstances, the water supply should be disinfected after returning the unit to normal operation. In the event of an alarm, a physical inspection of the unit with the power off should be done to try to identify a cause. If water should drip or leak onto the UV system, unplug the system and repair the leak (or add pipe insulation to prevent condensation runoff). Dry all remaining water and inspect the lamps and reflectors for water spots and clean them if necessary (See section on Replacing and Cleaning UV Lamps.) The reflectors are the shiny curved panels in front of and behind the lamps. The reflectors may be wiped with a clean soft cloth. If the reflectors do not come clean or are damaged, they must be replaced. A troubleshooting guide is provided with each alarm or warning message and Rev. 02/2015 Page 20 Product No
21 presented in the Menu Section of the Instruction Manual. Treatment Alarm KUV 1200x Owners Manual A Treatment Alarm occurs when the UV dose (energy) may be too low for effective treatment of pathogens in the water at the maximum flow rate specified for the system. This could be a result of low UV Intensity (lamps output too low) or low UV Transmittance (water quality below minimum specification) or both. By reviewing both the UVI and UVT output values in the Main Menu, the cause can be identified and corrective action taken as noted in the Troubleshooting section of the Manual. Navigating the Menu See the following pages to review system information including status, Treatment performance and Troubleshooting. Rev. 02/2015 Page 21 Product No
22 MAIN MENU When a unit is new or the UV lamps have been replaced and the Lifetime counter has been reset, the system begins an Initial Set-up process which may last 24hrs. Continue to operate unit. INITIAL SET-UP MAY TAKE 24HRS.. Alarm Conditon Exists Display Active Alarm message Kinetico KUV 1200x Self Diagnostics Starting Lamps Unit Treating Shutdown unit NO/YES You may safely unplug your unit Lamp life remain ## hours Reset Lamp Hours NO/YES Unplug unit and replace UV lamps Start up On Standby, Wait for Remote Start If Enabled - See Setup Use Up, Down, Left & Right Arrows to Navigate Use Right Arrow as Enter. Use Right Arrow to Change Value Use Right Arrow to Accept Value Use Right Arrow to silence audio alarm Use Left Arrow to Escape to Main Menu Net UVT UV Int. XX-XX% XX-XX% Service Menu Setup Menu KUV 1200x Alarms and Troubleshooting Message History See Following Sections See Following Sections See Following Sections See Following Sections SERVICE MENU MAIN MENU Service Menu Shutoff Valve AUTO Temperature Readings Shutoff Valve AUTO/ON/OFF UV Air Temp. deg C deg F Enabling/Disabling Valve is temporary. Items return to AUTO mode after 10 minutes. CB Air Temp. deg F deg C The Audio Alarm or beeper, can be temporarily or permanently disabled. Audio Alarm AUTO Audio Alarm AUTO/Disabled 24hrs/48hrs/ 1 week/off Technical Service Enter Password ###### LampStarts Total /Last 24hr ### / ### Power Ups ### Serial Number ###### Lifetime Counter ###### Program Version ###### Service Codes List values Rev. 02/2015 Page 22 Product No
23 SETUP MENU Setup Menu KUV 1200x Language English Language English/French Remote StartStop Disabled Remote StartStop Disable/Enable Unit Configuration Enter Password ###### Remote Device BIND # Bind Remote Device Remote Device BOUND ALARMS & TROUBLESHOOTING MENU This column represents all possible reasons for the fault. Alarms and Troubleshooting Lamp Alarm - Low UV Intensity Lamps need to burn in Continue to operate lamps ALARM UV Air Temp. High Check if filter dirty, fan fail Check if room temp within spec UV Air Temp. Low Check if room temp within spec Switch lamps & examine values Only one lamp may be low Sensor may have drifted New sensor or calibration reqd Lamps require replacement Install 2 lamps & reset counter Front Panel ajar Fully Close front panel Lamps not striking Front Panel ajar Fully Close front panel ALARM Check lamps or ballast Lamp Lifetime exceeded ALARM Lamps require replacement Install 2 lamps & reset counter End of Lamp Life Approaching WARNING Lamp cycling too often WARNING Reduce the # of lamp starts/day Rev. 02/2015 Page 23 Product No
24 ALARMS & TROUBLESHOOTING MENU (CONT D) This column represents all possible reasons for the fault. Alarms and Troubleshooting Treatment Alarm ALARM Low UVT Value HELPFUL TIP Review both UVI & UVT values Check Pretreatment devices Inspect unit for fouling Check reflectors Sensor may have drifted Lamps require replacement New sensor or calibration reqd Install 2 lamps & reset counter Front Panel Ajar WARNING Circuit board temperature high ALARM UV Chamber Temperature High WARNING Temperature Sensor Failure WARNING Microprocessor failure ALARM UV Sensor Failure ALARM Power reset Fully Close Front Panel Check CB fan operation Check if filter dirty, fan fail Check All Temp. Values Unplug unit and recheck. Check connection Power interruption occured Check if room temp within spec Check if room temp within spec MESSAGE HISTORY MENU Message History Alarm, Warning or Status messages Last 50 messages Message # Time #### hrs Time based on lamp counter Rev. 02/2015 Page 24 Product No
25 5. Maintenance Test the Optional Solenoid Shutoff Valve Monthly. The optional Solenoid Shutoff Valve, if installed, should be tested monthly to confirm proper operation, ie: that it opens and closes properly. To test it, unplug the valve from the system to confirm that the water stops flowing. Plug the valve back into the system to confirm that water starts flowing again. In that case, the valve is functioning properly. Clean the Air Filter Every 90 Days The KUV 1200x has a washable air filter in the blower housing panel (see Figure 1G). Wash by hand with water. Check that the blower operation is not impeded after filter cleaning. Replacing and Cleaning UV Lamps The system contains two ultraviolet (UV) lamps that emit high-intensity UV light in the germicidal frequency range, providing effective disinfection of the water flowing through the unit. The lamps will lose power over time and should be replaced every 12 months. Avoid starting and stopping the system more than two times within a 24 hr. period, as this will accelerate the aging of the UV lamps. (Note: Shutting down the system for seasonal use will extend lamp life.) The KUV 1200x has an internal lamp hour counter to keep track of the lifetime of the lamps. It will issue a warning when the end of their lifetime approaches (see Troubleshooting Guide). The amount of life remaining on the lamps is measured in hours and is displayed in the main section of the menu. The lamps can be easily replaced in minutes. Draining the system or removing it from the wall is not required. See Figure 3. Caution: The lamps in the unit emit ultraviolet (UV) light that can cause permanent damage to the skin and eyes. Never look at a lamp when it is operating. Always unplug the unit before replacing lamps. Caution: Never touch the bulb (transparent quartz portion) of a lamp with your fingers. Handle the lamp by its ceramic ends only. If the surface of the lamp becomes dusty or dirty, use a clean lint-free cloth and some rubbing alcohol to remove the dirt. For more difficult stains such as water spots, use a scale remover to remove the stain and then rubbing alcohol afterwards. The lamps are fragile and must be handled with care. Tools Needed Slotted screwdriver 3/16" Hex wrench (Allen wrench) NOTE: Resetting the Lamp Lifetime counter will clear the Message History, Lamp Starts counter and Power Ups counter. If this information is required, review it first before proceeding to Step 1. Rev. 02/2015 Page 25 Product No
26 Step 1: From the Main Menu, scroll down (push bottom arrow) to Lamp Life Remaining display screen. Press Enter to move to next screen that will allow you to reset the lamp hour counter. Press Enter again, and then push the Up or Down Key to select Yes and press Enter. The lamp hours will reset to 9000 Hours and the system will turn off the lamps automatically. This will close the optional Solenoid Shut Off-Valve, if installed, and temporarily shut off the water supply. Unplug the power cord from the left side of the system. Step 2: Remove the top cover by pulling each side of the plastic top cover outward from the system. When the top cover is removed, you will see two thumb screws that secure the front carriage door. Loosen the thumb screws so that the front carriage can be tilted forward to reveal the lamps. (You may need the 3/16 Allen Wrench if the thumb screws are very tight.) Lower the front carriage until it comes to a stop at 45 position. Step 3. CAUTION: The lamps are very hot after continuous use and can burn your skin on contact. Allow lamps to cool for five minutes before removing them. Slowly lift the old lamps out of the system. Do not twist the lamps as they are being removed. To help remove the lamps, insert a flat bladed screwdriver between the lamp base and its socket and lightly pry the lamps upward (see Figure 3). Dispose of the old lamps in the same way you would dispose of ordinary fluorescent lamps. Note that old lamps should be disposed of at a household waste management depot or transfer station; contact your local recycling and waste management authority for proper disposal procedures. Step 4: Install the new lamps into the KUV 1200x, being careful not to touch the bulb. Ensure that the lamps are aligned with the tab facing the outside of the system (left or right side of the system), or, if the lamps have a stop sign printed on the top ceramic, that the stop sign is facing inward. If you can see the stop sign, the lamps are backward (See Figure 3). Once the pins of the lamp begin to engage into the lamp socket, push firmly down on the top of the lamp. Do not twist the lamps when they are inserted. The lamp will come to rest when the pins are fully seated into the socket. When pressing down, be sure to position the lamp ceramic end in the center of the hole in the lamp holders. Repeat this for the other side. Step 5: Return the front panel to the upright position and secure it by tightening the thumbscrews. Replace the plastic top cover. Step 6: Record the date of the lamp replacement in your Service Record Sheet. Step 7: Plug in the KUV 1200x. The system will begin an Initial Set Up process while the lamps are reaching full power. The Green Indicator Lamp will flash and the Amber Indicator Lamp will be on. This process may take up to 24 hours. When the Initial Set-up process is complete, the Green Indicator lamp will be on and the message Unit Treating will be displayed in the LCD. Rev. 02/2015 Page 26 Product No
27 NOTE: DO NOT TWIST/TURN THE LAMPS WHILE PINS ARE ENGAGED TOP COVER CORRECT TAB ORIENTATION THUMB SCREW UV LAMP INCORRECT TAB ORIENTATION FRONT PANEL ASSEMBLY UNPLUG UNIT TO OPEN LAMP SOCKETS USE A SCREW DRIVER TO PRY LAMP UP HERE Figure 3 Draining the Unit The UV system does not require draining for routine operation or lamp replacement. Draining is necessary to disassemble the system, to protect against freezing or to remove poor-quality water. Step 1: Shut off the water supply. Step 2: Unplug the unit from the electrical outlet. Rev. 02/2015 Page 27 Product No
28 Step 3: Place a bucket under the unit to collect the water. Step 4: Open a faucet downstream of the unit. Step 5: If you have installed an optional drain valve, open the drain valve. If you do not have an optional drain valve, disconnect the water pipe below the unit and allow the system to drain for a few minutes. Step 6: When draining is complete, close the drain valve or reconnect the pipe. Step 7: Close any faucets that were previously opened. Cleaning the Unit (Quarterly Inspection Recommended) If the quartz water column becomes fouled due to water outside normal specified ranges, the Treatment alarm will display and alert you. Follow the steps below to inspect the quartz and disassemble the unit for quartz cleaning. Caution: Always unplug the system before performing any maintenance. Never operate a system unless the front panel is completely secured. Tools Needed Slotted screwdriver 3/16" Hex wrench (Allen wrench) Determining the Need for Cleaning PULL OUTWARDS AND LIFT REMOVE TOP COVER LOOSEN SCREW QUARTZ Figure 4A Rev. 02/2015 Page 28 Product No
29 Step 1: Shut down (see Menu Section) and unplug the system. Step 2: Remove the plastic top cover by pulling each side of the cover outward from the sides of the system and removing it. Then loosen the thumb screws holding the front carriage (You may need the 3/16 Allen Wrench if the thumb screws are very tight.) Step 3: Tilt the front carriage open until it comes to rest at a 45 position. Step 4: Examine the quartz sleeve visually. If it is clean, no disassembly is required. Return the front panel to the upright position and tighten thumb screws. Plug in the unit and operate as normal. If the quartz sleeve is dirty on the outside, proceed to wipe it down with a clean lint-free cloth and rubbing alcohol to remove the dirt. If the quartz sleeve is dirty on the inside, proceed with in-place cleaning or disassembly. Caution: The quartz sleeve can break or chip if mishandled. Always handle it with care and keep it in a safe place if it is removed from the unit. Do not strike the quartz sleeve with any tool, since even the smallest chip can cause it to break under pressure. In-Place Cleaning There are rare instances where water chemistry requires manual quartz cleaning. This procedure will clean the quartz without its removal from the unit. This is a quick and easy procedure that works well in most cases. Step 1: Fill a bucket or container with water before shutting off the water supply since you will need the water later to clean the quartz sleeve. A squeeze bottle is useful for applying water or cleaning solution to the inside of the quartz sleeve. Step 2: Unplug the system and open the front panel so that it is tilted forward to reveal the lamps. Lower the front panel until it comes to rest at a 45 position. Step 3: Place another bucket under the unit and drain the unit until there is about 1 (3cm) of water left in the quartz sleeve (see Draining the Unit). Step 4: Disconnect the top pipe. Step 5: Add about 2 oz. (60cc) of cleaning solution through the top opening. The cleaning solution can be a citric acid, vinegar or other non-hazardous slightly acidic solution. Any solution used should be thoroughly rinsed out afterwards. Fill the rest of the quartz with water. Step 6: Let the cleaning solution remain in the quartz for at least minutes. Step 7: It may be helpful to manually clean the inside of the quartz tube with a bottle brush. Rev. 02/2015 Page 29 Product No
30 Step 8: Drain the system and inspect the quartz sleeve. If clean, flush the unit with clean water. If fouling remains, repeat the cleaning procedure. Step 9: Once the unit is clean, reassemble the system. Step 10: Slowly open the water supply and check for leaks. Step 11: Replace all covers and plug in the KUV 1200x. Disassembling the Unit NOTE: This procedure is not recommended for individual household users. Please contact your certified water specialist for assistance if disassembly is required. REMOVE & SUPPORT TOP QUARTZ SEAL ASSEMBLY REMOVE TOP O-RING LIFT QUARTZ SLEEVE OUT OF THE UNIT REMOVE BOTTOM O-RING IF REQUIRED, REMOVE BOTTOM QUARTZ SEAL ASSY. REMOVE COVER: PULL OUTWARDS AND DOWN Figure 4B Rev. 02/2015 Page 30 Product No
31 See Figures 4B & 4C Step 1: Fill a bucket or container with water before shutting off the water supply since you will need the water later to clean the quartz sleeve (8). A squeeze bottle is useful for applying water or cleaning solution to the inside of the quartz sleeve. Step 2: Place another bucket under the unit and drain the unit (see Draining the Unit). Step 3: Open the front panel. The lamps may be removed to prevent them from getting dirty or damaged. Step 4: Disconnect the pipe from the top of the system and remove the top quartz seal assembly (Outlet Manifold). Caution: Do not damage the sealing surfaces of the Inlet/Outlet Manifolds (4). Handle these parts with care to prevent water leaks. Use a 3/16 Hex wrench to remove the four fasteners in an alternating pattern (top left, bottom right, bottom left, then top right). The bottom quartz seal assembly does not require removal to clean the quartz, so leave it in place. This will support the quartz sleeve during cleaning and simplify the overall process. Step 5: Remove the top quartz seal assembly (Figure 4B) by lifting it straight up. Removing and Cleaning the Quartz Sleeve Step 1: Use a bottle cleaning brush with a long handle to scrub the inside of the quartz sleeve. Scrub and flush it with water repeatedly to clean the quartz. Use a squeeze bottle to apply water or cleaning solution to the quartz sleeve to keep the area tidy. Note: Keep the rest of the system free from moisture. When cleaning is finished, re-examine the quartz sleeve. Step 2: If the quartz sleeve is still dirty, use a scale remover such as CLR or Lime Away and apply it to the inside of the quartz sleeve. Citric Acid, available at most drug stores, may also be effective. Always flush with clean water after cleaning. Step 3: Once the quartz is clean, reassemble the system (see Figure 4B). During reassembly, replace any seals that appear to have been damaged. Step 4: If the quartz is still not clean, it should be replaced. This is done by removing the bottom quartz seal assembly (see Figure 4B). Step 5: Remove the bottom cover and then the bottom quartz seal assembly. To remove the plastic bottom cover, pull the sides of the plastic outward and down, then remove the four fasteners holding the bottom manifold on, in an alternating pattern (top left, bottom right, bottom left, then top right). Support the quartz sleeve as you remove this manifold. Rev. 02/2015 Page 31 Product No
32 Step 6: Remove the quartz sleeve by removing the top and bottom O rings (13). Lift the quartz sleeve out of the system. Step 7: Install the new quartz sleeve into the system and center it vertically. Be careful not to chip the ends of the quartz sleeve. You may open the front of the system to help align the quartz sleeve if necessary. Support the quartz for the next two steps. Step 8: Replace the top and bottom O-rings, keeping the quartz centered vertically in the unit. Step 9: Replace the bottom quartz seal assembly (see Figure 4B) by installing the four fasteners in an alternating pattern (top left, bottom right, bottom left, then top right). Ensure that the inlet connection port is at the backside of the unit. Reassembling the Unit Step 1: Ensure the quartz O-ring seal is in place around the quartz sleeve and then replace the top quartz seal assembly. Step 2: Tighten the fasteners in an alternating pattern. Step 3: Reconnect the pipes, both top and bottom. Close and fasten the front panel. Step 4: Close any faucets and open the water supply. Inspect for leaks. The optional solenoid shut-off valve (if installed) can be placed into manual mode to allow water to enter the unit. Switch back to automatic mode when done. Repair any leaks if necessary. Caution: Do not operate the system if there are any leaks at the piping connections or within the UV system. Step 5: Replace the lamps. Step 6: Reinstall the top and bottom covers. Step 7: Plug in the KUV 1200x. Replacement Parts Use only genuine replacement parts when servicing your UV. UV Spare Parts Replacement parts and service are available from your Kinetico dealer. A complete list of Kinetico dealers is available on Kinetico s website: kinetico.com. Rev. 02/2015 Page 32 Product No
33 Figure 4C KUV 1200x 15 Rev. 02/2015 Page 33 Product No
34 Item No. Kinetico Part No. Qty. KUV 1200x Parts List Description LAMPS (SHIPPED IN PAIRS-SINGLE LAMP P/N E300209) V CIRCUIT BOARD UV SENSOR ARRAY REPLACEMENT KIT TOP/BOTTOM INLET/OUTLET MANIFOLD, 1" CABINET DOOR FOR KUV 1200x REACTOR COOLING BLOWER KIT (INCLUDES FILTER) FAN FILTER QUARTZ SLEEVE REPLACEMENT KIT (INCLUDES 2 O RINGS) 9-1 TOP OR BOTTOM CAP AIR THERMISTOR REPLACEMENT KIT CIRCUIT BOARD COOLING FAN REPLACEMENT KIT REFLECTOR KIT (SHIPPED AND SOLD IN PAIRS) SEAL KIT (COMPLETE) LAMP SOCKET WIRE HARNESS " SOLENOID SHUTOFF VALVE (FOR 115V SYSTEMS) TRANSIENT VOLTAGE SURGE SUPRESSOR FOR 115V SYSTEMS Figure 4C Parts List Rev. 02/2015 Page 34 Product No
35 Date of Purchase: Dealer Name: Model: Serial Number (located on the left side of the front panel below power cord entry): 6. Service Record Sheet Record lamp replacement dates and events in the space provided below. Date (MMM/DD/YYYY) Action System Installed Rev. 02/2015 Page 35 Product No
36 7. Limited Warranty Limited Warranty for Kinetico UV water purification systems and peripheral parts purchased in Canada, the United States, Australia and New Zealand. What This Warranty Covers: Defects in materials and workmanship in Products and Parts manufactured, sold or certified by Kinetico Incorporated including systems and parts such as replacement UV lamps, solenoid valves and other components sold or certified by Kinetico Incorporated. What the Period Of Coverage Is: Five-year Limited Warranty for structural, hardware and mechanical components. Specifically, this includes the following Parts: system casing (powder coated steel parts, machined and extruded aluminum parts, stainless steel parts and ABS components), stainless steel manifolds and mechanical fasteners. Three-year Limited Warranty for electrical components and quartz sleeve. Specifically, this includes the following Parts: muffin fan, blower, ballast and micro-processor with digital display, optional solenoid valve, wiring harnesses, lamp sockets and reflectors. One-year Limited Warranty, on a pro-rated basis, for lamps and sensor probes. Specifically this includes the following Parts: UV lamps, UV sensors and the circuit board they are mounted in and temperature probes. If the Part fails within 90 days, it will be replaced or repaired at no charge. If the Part fails after 90 days and before 181 days, it will be replaced or repaired at one-quarter of the then current Manufacturer s Suggested Retail Price (MSRP). If the Part fails after 180 days and before 271 days, it will be replaced or repaired at one-half of the then current MSRP. If the Part fails after 270 days and before 365 days, it will be replaced or repaired at three-quarters of the then current MSRP. Ninety-day Limited Warranty or Balance of Original Warranty for replacement Parts or Products. Specifically this includes any Parts or Products replaced or repaired under this Limited Warranty, and any Parts purchased for routine service or maintenance including UV lamps. This warranty period is for the balance of the original warranty or for 90 days from the date the Product or Part is repaired and/or returned to the first end-user, whichever is longer. Who Is Covered: This Limited Warranty begins from the date of original system installation and extends to you only if you are the FIRST END-USER PURCHASER with respect to the ORIGINAL INSTALLATION. What We Will Do To Correct Problems Covered By This Limited Warranty: During the warranty period, as set out above, Kinetico will repair or replace Products or Parts at its sole discretion and cost, with the exception of shipping Rev. 02/2015 Page 36 Product No
37 and handling charges. Replacement parts or systems may be functionally equivalent reconditioned/refurbished/pre-owned or new products or parts at Kinetico s sole discretion. Kinetico may provide software updates, at its discretion, but is under no obligation to do so. Based on an agreement between Kinetico and its service providers, Kinetico dealers, this warranty will be honored by either Kinetico or a Kinetico dealer. How To Get Help: Call your local Kinetico dealer. A complete list of Kinetico dealers is available on Kinetico s website: kinetico.com. Make sure you have available the model number, serial number and date of installation. What This Limited Warranty Does NOT Cover: Maintain your original PROOF OF PURCHASE. Kinetico or its Kinetico dealers reserve the right to deny warranty coverage if you cannot provide proof of original purchase including date of installation, who you purchased the Product or Part from and serial number. Kinetico is not responsible for Parts or Products that are improperly installed, used or not maintained as set out in the Product Manual or as expressly advised by Kinetico. This Limited Warranty does not cover damage caused by accidents, acts of God, minor scratches or imperfections and normal wear and tear including faded paint or minor corrosion due to atmosphere conditions. This Limited Warranty is void if the Product is improperly installed, used in conditions that exceed Kinetico s specifications as set out in the Manual or Product Specifications, or if there is water damage due to improper installation or poorly or improperly tightened plumbing connections. This Limited Warranty is void if the Product or Parts have been altered or modified in any way by anyone other than a Kinetico technician or a Kinetico dealer. Warranty coverage may be void if the Product is operated in combination with ancillary or peripheral equipment not approved by Kinetico for use with the Product. Installation of the supplied Transient Voltage Surge Suppressor (TVSS)/Surge Protective Device (SPD) that has been certified to the UL 1449 standard or equivalent by an NRTL/C that includes integral Over/Under Voltage shutoff protection between the system and a grounded power outlet, is required. This Limited Warranty excludes the cost of labor in removing and/or reinstalling any defective Product or Part. In the event that a Product is returned to Kinetico for repair or replacement under the terms of this Limited Warranty, the Product must be retuned in its original shipping container and packaging. Kinetico will not be liable for damage to the Product during shipping otherwise. Kinetico does not assume any liability for personal injury or property damage caused by the use or misuse of any Product or Part. Kinetico is not liable for special, incidental, indirect or consequential damages. Kinetico s liability is limited to repair or replacement of the defective Part or Product and this liability shall terminate upon expiration of the applicable warranty period as set out above. Rev. 02/2015 Page 37 Product No
38 THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY AND ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW. THERE ARE NO WARRANTIES OTHER THAN THOSE CONTAINED HEREIN. IN NO EVENT SHALL KINETICO BE LIABLE FOR INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE USE OR THE LOSS OF USE OF THIS SYSTEM. This Limited Warranty may be amended or changed at any time, at Kinetico s sole discretion, without notice. Registration and Service To place your system under warranty, your authorized Kinetico dealer must register your equipment with Kinetico Incorporated within 30 days of the installation date. For service under this warranty, contact your authorized Kinetico dealer. Retain your receipt along with this warranty for reference if service is necessary. Rev. 02/2015 Page 38 Product No
39 Kinetico Incorporated 2015 Corporate Headquarters Kinsman Road Newbury, Ohio Product No
KINETICO ULTRAVIOLET WATER PURIFICATION SYSTEM
Owners Manual KINETICO ULTRAVIOLET WATER PURIFICATION SYSTEM MODEL: KUV 1200 Conforms to UL60335-1E:04. Certified to CAN/CSA-E60335-1/4E:03 OWNERS MANUAL Copyright Kinetico Incorporated 2009 All rights
UV Pure Technologies Inc. WATER PURIFICATION SYSTEM
Owner s Manual UV Pure Technologies Inc. WATER PURIFICATION SYSTEM MODEL: CACTUS Conforms to UL60335-1E:04. Certified to CAN/CSA-E60335-1/4E:03 OWNERS MANUAL Copyright UV Pure Technologies Incorporated
UV Pure Technologies Inc.
UV Pure Technologies Inc. ULT RAVIOLET WAT ER PURIFICAT ION SYST EM INSTRUCTION MANUAL Hallett 30 1 Systems MODEL: Hallett 30 VOLTAGE: SERIAL #: Hallett 30 1 NSF/ANSI 55 CLASS A CERTIFIED Certified to
UV Pure Technologies Inc.
UV Pure Technologies Inc. ULT RAVIOLET WAT ER PURIFICAT ION SYST EM INSTRUCTION MANUAL MODEL: VOLTAGE: SERIAL #: Certified to IEC PUBLICATION 60335.1 EDITION 4 th INSTRUCTION MANUAL Copyright UV Pure Technologies
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Lamp and Sleeve Replacement
Lamp and Sleeve Replacement G, H, J & K G Plus, H Plus, J Plus & K Plus Pro0, Pro0, Pro30 & Pro50 Always shut-off water flow and release water pressure before servicing. Electrical hazard. Be sure to unplug
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
Installer s Guide 18-GJ11D1-2 : Models: BAYUVCLK001-40 Watt, 2 Lamp NOTE: A BAYCC24VK01 can be installed for Series 8 Air Handlers to extend the life of the lamp. This accessory kit will disable the lamp
MAINTENANCE & TROUBLESHOOTING
MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning
MAINTENANCE & TROUBLESHOOTING
MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens clean the fan intake filter replace the projection lamp replace the batteries in the remote control use the Kensington lock feature
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION & MAINTENANCE MANUAL SERIES DLR VERSION M MODEL 4-M 7-M.
INSTALLATION OPERATION & MAINTENANCE MANUAL SERIES DLR VERSION M MODEL 4-M 7-M WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT System Tested and Certified by NSF International against NSF/ANSI Standard
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930 WARNING Ultraviolet light is harmful to eyes and skin. Never look at light produced by this lamp. Unplug lamp before servicing. Electrical
B150 Series Commercial Brewer. Direct Plumb Kit
B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
HP ProDisplay P19A LED Backlit Monitor. User Guide
HP ProDisplay P19A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
Installation Instructions
Installation Instructions Accessory Ultraviolet (UV) Germicidal Lamp 1 & 2 Lamp Models 115-v & 208/230-v UV Lamp C03009 Fig. 1 Two Lamp Model UV Lamp NOTE: Read the entire instruction manual before starting
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
UPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
UV100A Ultraviolet Air Treatment System
UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
INSTALLATION AND SERVICE MANUAL
CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Stenner Pump Chlorinator Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Stenner Pump Chlorinator Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S 1 2 4 7.
INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT SERIES NO'S 1 2 4 7 Sold by: Manufactured by: WEDECO Ideal Horizons, Inc. 3520 Westinghouse
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Quick Start Guide See Inside for Use and Safety Information
3 rd Generation Personal 3D Printer Quick Start Guide See Inside for Use and Safety Information The USB Mass Storage Device Contains the User Guide and Quick Start Guide in other Languages Congratulations
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply
User Manual English APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC Tower Uninterruptible Power Supply 990-1587A 12/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS
Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 W 2010 S, Syracuse, Utah 84075 USA Voice: 801-825-4523 Website: www.sunshinepool.com Email: [email protected] POOL SUNSHINE
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
HAIR CLIPPER. Model No. HC5150 HC5150 2. 3.
All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,
OWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179
Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export
Part No. 61745-01 Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export IMPORTANT SAFETY INSTRUCTIONS a. Read these instructions. b. Keep these instructions. c. Follow
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0
VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully
Installation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
MAC FAUCETS. Owner s Manual. Models: FA444
MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect
750VA/1000VA/1500VA 100/120/230VAC 2U
User s Manual English Smart-UPS 750VA/1000VA/1500VA 100/120/230VAC 2U Rack Mount Uninterruptible Power Supply 990-1194 5/02 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
Nexus FS Point of Use Installation Guide
Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7
Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important