User s Guide CN8200 SERIES. Communications & Options Guide. omega.com. info@omega.com

Size: px
Start display at page:

Download "User s Guide CN8200 SERIES. Communications & Options Guide. omega.com. www.omega.com e-mail: info@omega.com"

Transcription

1 User s Guide omega.com info@omega.com TM CN00 SERIES & s Guide

2 USA: ISO 00 Certified One Omega Drive, Box 0 Stamford CT Tel: (0) -0 FAX: (0) info@omega.com omega.com OMEGAnet On-Line Service It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications. Internet info@omega.com For immediate technical or application assistance: USA and Canada: Sales Service: / -00-TC-OMEGA Customer Service: / -00--BEST Engineering Service: / -00-USA-WHEN TELEX: 0 EASYLINK: CABLE: OMEGA Benelux: Postbus 0, 0 LA Amstelveen The Netherlands Tel: () 0 0 FAX: () 0 Toll Free in Benelux: nl@omega.com Czech Republic: Rudé armády, 0 Karviná Tel: 0 () FAX: 0 () Toll Free: czech@omega.com France:, rue Denis Papin, 0 Trappes Tel: () FAX: () 0--0 Toll Free in France: france@omega.com Servicing Europe: TM Canada: Bergar Laval (Quebec) HL A Tel: () - FAX: () - info@omega.ca Mexico: Tel: (00) 00-- FAX: (00) 0--0 En Espan ~ ol: (00) espanol@omega.com Germany/Austria: Daimlerstrasse, D- Deckenpfronn, Germany Tel: (00) 0 FAX: (00) 0 Toll Free in Germany: 000 TC-OMEGA SM germany@omega.com United Kingdom: ISO 00 Certified One Omega Drive River Bend Technology Centre Northbank, Irlam Manchester M EX England Tel: + (0) FAX: + (0) Freephone: sales@omega.co.uk Table of Contents For information and instructions related to basic operations, refer to the Series CN00 operator s manual supplied with your controller. s Wiring Diagrams Dual Alarm Outputs (s -AL) Dual Volt DC Alarm Outputs ( -AL) Relay, N.O. Alarm Output ( -AL) RS- ( -C) RS- ( -C) Contact/ Input with Alarm (s -RSP, -RSP, -RSP ) 0 Transducer Excitation (s XP, -XP, -XP, -XP) Process Output (s -PVSV, -PVSV) Guide to Remote s Omega+ Protocol - Message Format - Sample Commands - Request Messages - Response Messages - Parameter List - Auxiliary Commands - Error Codes 0

3 Dual Alarm Outputs -AL: Dual Alarm Output, N.O. Dual Vdc Alarm Outputs -AL: Dual Vdc Alarm Outputs This optional hardware module provides two alarm drive outputs. LED indicators A and A are used to indicate alarm conditions as configured in the Alarm Menu. TYPICAL OUTPUT CONNECTION TYPICAL CONNECTION USING PIEZOELECTRIC AUDIBLE ALARM DEVICE AMP FUSE LOAD 0-0 VAC MANUFACTURED WITH DUAL VDC ALARM OPTION BOARD. PART #A0U0 SONALERT CONTROLLER V OUTPUT CONFIGURATION V AMP FUSE LOAD 0-0 VAC LED INDICATOR K FIELD CONNECTIONS FIELD CONNECTIONS 0 0 TYPICAL CONNECTION USING LED INDICATOR WITHOUT LIMITING RESISTOR Description: -AL: Dual alarm, N.O. Load Limits: Max. Load Current A rms Min. Load Current 0. ma rms Power Factor Range 0. to.0 (can drive small motors, solenoids, valves, and contactors) Max. Surge Current Non-repeating for second. A Max. I T for fusing (0.0 sec). amp-squared seconds ( A - ABC typical fuse) Description: Isolation: Dual V outputs with clamping diodes Pins & are connected internally Source current is limited to ma (000 ohm resistor) Open circuit voltage is volts Isolation 00 volts ac/dc either output to instrument

4 Relay, N.O. Alarm Output -AL: Relay, N.O. Alarm Output AMP FUSE LOAD * SUPPLY VOLTAGE * RS- -C: RS- (one-to-one) 0 FEET OR LESS COMPUTER TX RX 0 FIELD CONNECTIONS GND Description: NO (Normally open) relay contact is closed when either alarm is active. Jumpers on the board can be removed to activate the output for a single alarm only: JP - Alarm A JP - Alarm A RX TX 0 D-SUB STYLE PIN MALE FIELD CONNECTIONS The relay life is greater than 00,000 operations at operations per second switching full load. *Connect load and supply voltage per the following table: Load Type Amp Voltage Limit Resistive DC 0 Vdc Inductive DC (L/R = ms) 0 Vdc Resistive AC 0 Vac Inductive AC (pf = 0.) 0 Vac Motor, AC, / hp 0 Vac Tungsten Lamp, 0 W 0 Vac Description: Provides a one-to-one connection between the controller and an RS- port. Computers, PLCs, or dumb terminals may be used to set and access controller data.

5 RS- -C: RS- (one-to-many) Contact/ Input with Alarm s -RSP, -RSP, -RSP Remote Setpoint Switch, with Alarm (Contact Input) RS-/RS- CONVERTER (Athena P/N C00U0)* DATA CABLE ASSEMBLY DB MALE/MALE COMPUTER Input Menu UP TO 000 FEET FIELD CONNECTIONS D-SUB STYLE PIN FEMALE SOLDER PIN CONNECTOR 0 TO PINS AND (-) TO CONTROLLER TERMINAL (+) TO CONTROLLER TERMINAL AMP FUSE ALARM LOAD 0-0 Vac 0 OHMS Description: LAST CONTROLLER TERMINATION (UP TO CONTROLLERS) Provides one-to-many communications. If run exceeds 000 ft., terminate the controller furthest from the computer by connecting a 0-ohm, /-watt resistor between terminals and. *Converter is supplied with a wallplug-mount power transformer. Description: 0 OR OPTIONS 0 AND FIELD CONNECTIONS 0 OPTION Dual function board (functions unrelated) a. Output alarm is energized when either A or A is active. b. input controls Remote Standby, Ramp- Soak Run/Hold, OR Second Setpoint Select. (+) 0 ma max. (-)

6 RS- s -C-DIC, -C-DIO, -C-DIV, -C-MOD, -C-MOD-DIC, -C-MOD-DIO, -C-MOD-DIV: Input plus RS- Contact/ Input with Alarm TO PINS AND 0 UP TO 000 FEET RS-/RS- CONVERTER* s -C-DIC, -C-DIO, -C-MOD-DIC, -C-MOD-DIO RS DATA CABLE ASSEMBLY DB MALE/MALE COMPUTER D-SUB STYLE PIN FEMALE SOLDER PIN CONNECTOR Load Limits: Max. Load Current: Min. Load Current: Power Factor Range: Max. Surge Current, Non-Repeating for second:. A Max. I T for fusing (0.0 sec): -RSP: Active when switch closed. -RSP: Active when switch open. -RSP: Active when V input present A rms 0. ma rms 0. to.0 (can drive small motors, solenoids, valves, and contactors). amp-squared secs (A - ABC typical fuse) 0 OHMS OR LAST CONTROLLER TERMINATION (UP TO CONTROLLERS) (+) 0 ma max. (-) s -C-DIV, -C-MOD-DIV TO CONTROLLER TERMINAL (-) (+) TO CONTROLLER TERMINAL Note: See previous page for control input menu selections Description: 0 Provides one-to-many communications. OPTION If run exceeds 000 ft., terminate the controller furthest from the computer by connecting a 0-ohm, /-watt resistor between terminals and. *Converter is supplied with a wallplug-mount power transformer. 0

7 Transducer Excitation -XP, -XP, -XP, -XP: Transducer Excitation Auxiliary Output -PVSV, -PVSV: Process Output Menu ( - 0 Vdc INPUT) RELATIVE HUMIDITY SENSOR OR VOLT OUT Description: The transducer excitation option provides power to remote transducers. The transducer outputs, in turn, provide a signal to the controller input which can be scaled in the appropriate engineering units. -XP: Vdc -XP: Vdc -XP: 0 Vdc -XP: Vdc All options will provide at least 0 ma. The transducer circuitry is thermally protected from short circuits.

8 Auxiliary Output -PVSV, -PVSV: Auxiliary Output Description: 0 FIELD CONNECTIONS /0 ma REMOTE INDICATOR 0/0 ma REMOTE INDICATOR (OPTION ( 0 -PVSV) AND ) 00 OHM RESISTOR MUST BE CONNECTED BETWEEN PINS & FOR VOLTAGE OPTIONS (OPTIONS & ) - V INDICATOR 0 - V INDICATOR ( (OPTION -PVSV) & ) The Setpoint Variable or Process Variable is transmitted to a remote device (chart recorders, indicators, data recorders, computers, process controllers, etc.) with of different interfaces: -PVSV: -0 ma -PVSV: 0- V The output signal is scalable in the Auxiliary Output Menu. Multiple remote indicators may be driven by the controller. For current (ma) options, the remote indicators are connected in series. The sum of the input resistance for all remote indicators must be less than 00 ohms. For voltage options, the remote indicators are connected in parallel. The sum of the currents for all remote indicators must be less than 0 ma. Three remote communications options are available for the CN00 which allow interfacing to remote devices utilizing the most common industry standards: RS and RS. Remote s RS- This method allows bidirectional data transfer via a threeconductor cable consisting of signal ground, receive input and transmit output. It is recommended for communication distances less than 0 feet between the computer terminal and the instrument. Note: Multiple instruments cannot be connected to the same port. The RS port is optically isolated to eliminate ground loop problems. Typically, Data Out of the computer/ terminal connects to the RCV terminal. Data In connects to the XMT terminal. If shielded cable is used, it should be connected to the frame ground at one end only. Signal ground is to be connected at appropriate ground terminals (refer to wiring diagram on next page). RS- The RS multipoint capability allows up to controllers to be connected together in a half-duplex network or up to 00 controllers with an appropriate communications repeater.

9 Note: Call factory for a recommended RS converter. Figure a. Wiring diagram for RS- digital communications. RX TX 0 0 FEET OR LESS GND FIELD CONNECTIONS This method allows bidirectional data transfer over a twisted pair cable. The twisted pair cable is a transmission line; therefore, terminating resistors are required at the most distant ends of the line to minimize reflections (typically 0 ohms at each end). The RS circuit is fully optically isolated, eliminating ground loop problems. Parallel drops from the transmission lines should be kept as short as possible; however, the line may be daisy-chained at each controller. The polarity of the line is important and each device will specify an A (+) and B (-) connection. TX RX D-SUB STYLE PIN MALE COMPUTER Figure b. Wiring diagram for RS- digital communications. UP TO 000 FEET 0 TO PINS AND RS-/RS- CONVERTER (Athena P/N C00U0)* FIELD CONNECTIONS (-) TO CONTROLLER TERMINAL (+) TO CONTROLLER TERMINAL DATA CABLE ASSEMBLY DB MALE/MALE COMPUTER D-SUB STYLE PIN FEMALE SOLDER PIN CONNECTOR Omega+ Protocol The Omega+ Protocol provides an easy way to query and modify controller parameters using a personal computer and the optional digital communications option of the CN00. In this manual, the word host refers to the personal computer that s communicating with the controllers in the serial link, and the word slave refers to the controllers themselves. All transactions between the host and the slaves are done with messages consisting of only printable ASCII characters. There are only two primary types of messages: Requests and Responses. Messages coming from the host are called requests and messages coming from the slaves are called responses. With the exception of a broadcast request, for every request sent from the host, the slave will send back a response. If a slave does not respond within 00 milliseconds, then the request can be considered lost. A broadcast request is a request having an ID of 00 (see Message Formats on next page). It is used to address all slaves on the network. All slaves on the network will perform the actions requested in a broadcast message. However, a response message will not be returned. Therefore, the host can only broadcast Write or Auxiliary Command Requests. All slaves will ignore all Read Broadcast Requests. 0 OHMS LAST CONTROLLER TERMINATION (UP TO CONTROLLERS)

10 Menu Omega+ Protocol (Standard) Message Formats All Omega+ messages adhere to the general format of: [START CHAR][ID][ZONE][TYPE][PARAM][ERROR] [DATA][CHKSUM][END CHAR] START CHAR This is a single character which designates the start of the message. For a Request message, this character is the ASCII $ and for a Response message, this character is the ASCII %. Defined as start bit / N# data bits / Parity odd, even, none / N# stop bits ID This is a two-character ID identifying the receiving controller. Controller IDs go from - inclusively and all slaves in the network must have unique IDs. The ID number of 00, when used in a request, designates a broadcast message that is used to address all controllers in the network. See the section Request Message for an explanation of the broadcast message. In order to represent with just two ASCII characters, a number system known as the Message Code Numbering System is used. In this system, the most significant digit is represented with the numbers 0- and the letters A-Z and the least significant digit is represented with the numbers 0-.

11 The numbers 0- have the same values as their decimal counterparts and the letters A-Z have the values of 00-0 inclusively in increments of 0. Type This is a single character identifying the type of message. The following table lists the type characters for all messages. Example: Message Code Value = Decimal Value = = A = 00 A 00 + = 0 B 0 + = P 0 + = Zone This is a two character ID identifying the Zone number in multi-zone capable controllers. For the CN00, this number must be 0. TYPE character R r W w A Message Type Read Request or Read Response Returning a Positive Result Read Response Returning a Negative Result Write Positive Value Request and Response Write Negative Value Request and Response Auxiliary Command For further information, see following sections on the different message types. 0

12 PARAM This is a two character, message specific, parameter ID. For a Read/Write Request or Response message, this ID identifies the controller parameter. For an Auxiliary Command Request or Response message, this ID specifies the command. STATUS This is a single-character field used in all response messages, containing a status code specifying the status of the request message received. IMPORTANT: The data field in the Read and Write Request and Response messages must and will only contain the characters 0 -, and the decimal point.. All other characters are considered illegal. When the data field is listed as Unused or Ignored in an auxiliary command, it does not mean that the field can be skipped when sending in the request message. Instead, this field must be padded with any 0 alphanumeric (only letters and numbers are allowed) ASCII characters. DATA This field contains the ASCII representation of the value of the parameter. For the Auxiliary Request or Response messages, this field either contains the ASCII representation of a numeric value or just ASCII data. The length of this field depends on the message type. The discussion on the specific message types gives the exact requirements for this field. All ASCII representations of numeric values must be done using the characters 0 -, and.. Any use of other ASCII characters, including and - will result in a bad message. Negative numbers CANNOT be represented by preceding the number with - character. Instead, a special message type is used. See subsequent sections for more information.

13 Examples of valid numeric representations for a character data field: Numeric Value.0000 ASCII Representation CHKSUM This is a two character Message Code Numbering System, representing the sum of all the ASCII values of all the characters (excluding the START, CHAR, the END CHAR, and the CHKSM themselves) in the message. The sum is computed using the following formula: CHKSM = SUM(All Message Characters)% % represents the modulus operator. END CHAR This is a single character designating the end of the message. For all messages, the character used is <CR>, the carriage return. Examples of invalid numeric representations for character data field: (B represents a blank, or a space, character) Numeric Value Bad ASCII Representation Why? BBBBB Leading blanks.0bbbb are not allowed. Trailing blanks are not allowed is not allowed. Request Messages: Request Messages are sent from the host to the slaves. Each request will have an ID identifying the intended recipient of the request. If the ID is 00 (zero), then the request is a broadcast message. All slaves will perform the action requested in the broadcast request. However, a response message will not be returned. Therefore, it only makes sense to send Write or Auxiliary Command Requests as broadcast requests. There are three types of Request Messages: Read, Write, and Auxiliary Commands.

14 The Read Request: The Read Request is used to query parameter values and it has the following message format: [START CHAR][ID][ZONE][TYPE][PARAM][CHKSUM][END CHAR] Field Description: TYPE Must contain the uppercase letter R. Request Message $ØØRØC<CR> $ØØRØC<CR> $ØØRØC<CR> Description Queries the value of the Process Variable of Controller #. Queries the value of the EEPROM Setpoint of Controller # Queries the value of the EEPROM Setpoint of Controller #. END CHAR CHKSUM PARAM TYPE ZONE ID START CHAR Examples of the responses to these requests are given in later sections on Response Messages. The Write Request: The Write Request is used to modify parameter values and it has the following message format: [START CHAR][ID][ZONE] [TYPE][PARAM][DATA][CHKSUM][END CHAR] Field Description: TYPE This field must contain one of the following two characters. Request Message W Value in DATA is a positive value. w Value in DATA is a negative value. DATA A six-character ASCII representation of a numeric value. Description $ØØWØØ.G<CR> Change both the RAM and EEPROM copies of Setpoint # in controller # to the value of 0. $ØØwØØ.J<CR> Change only the RAM copy of setpoint # in controller # to the value of -0. (notice the lowercase w ). END CHAR CHKSUM DATA PARAM TYPE ZONE ID START CHAR

15 The Auxiliary Command Request: The Auxiliary Command Request is used to issue commands to the controllers and it has the following message format: Field Description: TYPE This field must contain the uppercase letter A Request Message $ØØAØXXXXXXXXXXL<CR> $ØØAØØØØ.ØØØØØ<CR> DATA A ten-character ASCII representation of a numeric value or 0 alphanumeric ASCII characters. Description Tell controller # to load all parameters with their defaults. The 0 X s are padding characters. Tell controller # to perform a low RTD calibration. Response Messages: Response Messages are replies to the requests sent from the host. For each request received, the slave will reply back with a response. For all requests, the Omega+ Protocol specifies a maximum response time of 00 milliseconds. If a response is not received after 00 milliseconds, that request can be considered lost. There are three types of Response Messages: Read, Write, and Auxiliary Commands. END CHAR CHKSUM DATA PARAM TYPE ZONE ID START CHAR

16 The Read Response: The Read Response will be sent in response to a Read Request. Some examples: The Write Response: The Write Response will be sent in response to a Write Request. Some examples: Request Message Description Request Message Description %ØØRØØ.K<CR> %ØØRØG<CR> %ØØrØØ.ØØØN<CR> The value of the Process Variable is. Degrees C. A serial transmission has occurred: Framing Error The value of the EEPROM setpoint # is - Degrees C (notice the lowercase r ). END CHAR CHKSUM DATA STATUS PARAM TYPE ZONE ID START CHAR %ØØWØI<CR> A serial transmission error has occurred: Parity error. Write failed. %ØØwØØK<CR> RAM copy of setpoint # modified successfully. END CHAR CHKSUM STATUS PARAM TYPE ZONE ID START CHAR 0

17 The Auxiliary Command Response: The Auxiliary Command Response will be sent in response to an Auxiliary Command Request. Table. Parameter List (Omega+ Protocol) Parameter Parameter Some examples are: Number Description Number Description Controller Type Manual Control Request Message Description Software Version Percentage Ø Output Deadband %ØØAØØXXXXXXXXXXØ<CR> Default load all parameters has started. Version Output Hysteresis Status Byte Output Proportional %ØØAØØØ.ØØØØØØØØB<CR> RTD low calibration Process Value Band on controller # has Operating Mode Output Proportional started. Access Level Band END CHAR Contact/ Ø Rate/Derivative Action CHKSUM Input State Reset/Integral Action Setpoint - RAM, Manual Reset/ DATA EEPROM Internal Action STATUS Ø Setpoint - RAM Output Deadband PARAM Only Output Hysteresis TYPE Second Setpoint - Autotune Damping ZONE RAM, EEPROM Ø Recipe ID Second Setpoint - Single Setpoint Ramp START CHAR RAM Only Time Remote Analog Ramp Time Setpoint Ramp Time Recipe Setpoint Ramp Time Output Percentage Ramp Time Output Percentage Ramp Time Manual Control Ramp Time Percentage Ramp Time

18 Table. Continued Parameter Parameter Number Description Number Description Ramp Time Soak Time Ø Ramp Event Soak Event Ramp Event Soak Event Ramp Event Soak Event Ramp Event Soak Event Ramp Event Soak Event Ramp Event Soak Event Ramp Event Ø Soak Event Ramp Event Soak Event Soak Level Recycle Number Soak Level Holdback Band Ø Soak Level Termination State Soak Level Power Resume Soak Level Input Bias Soak Level Input Low Scale Soak Level Input High Scale Soak Level Lower Setpoint Limit Soak Time Ø Upper Setpoint Limit Soak Time Input Filter Soak Time Input Type Soak Time Output Type Ø Soak Time Output Action Soak Time Output Alarm Soak Time Action Table. Continued Parameter Number Description Output Alarm Operation Output Alarm Delay Output Alarm Inhibit AØ Output Process Alarm Setpoint A Output Deviation Alarm Setpoint A Output Cycle Time A Output Low Limit A Output High Limit A Output Type A Output Action A Output Alarm Action N/A A Output Alarm Operation A Output Alarm Delay N/A BØ Output Alarm Inhibit B Output Process Alarm Setpoint B Output Deviation Alarm Setpoint B Output Cycle Time B Output Low Limit B Output High Limit Parameter Number Description B TC/RTD Decimal Position B Linear Decimal Position B Display Filter B Display Units C Display Blanking C Alarm Action C Alarm Operation C Alarm Delay C Alarm Inhibit C Alarm Process Setpoint C Alarm Deviation Setpoint C Alarm Action C Alarm Operation DØ Alarm Delay D Alarm Inhibit D Alarm Process Setpoint D Alarm Deviation Setpoint D Communication Protocol D Communication ID D Communication Baud Rate D Communication Data Format D Communication Transmit Delay E Output Failsafe % E Output Failsafe %

19 Table. Continued Parameter Number Description E Loop Break Time E Highest Reading E Lowest Reading E Selection N/A E TC Zero Calibration FØ TC Span Calibration F RTD Zero Calibration F RTD Span Calibration F Low-Voltage Zero Calibration F Low-Voltage Span Calibration F High-Voltage Zero Calibration F High-Voltage Span Calibration F Current Zero Calibration F Current Span Calibration G Auxiliary Output Variable G Auxiliary Output Scale Low G Auxiliary Output Scale High G RAS Scale Low G RAS Scale High Parameter Number Description G Contact/ Switch Function H Autotune State H Recipe State H Current Recipe Segment H Active Setpoint H Resume Exhaustion Flag F Low-Voltage Span H LED Status Indicator H RTD (with decimal support) Zero Calibration IØ RTD (with decimal support) Span Calibration Auxiliary Commands: Command: Load Parameter Defaults Parameter #: 0 Description Request Data Field: Response Data Field: Command: Parameter #: 0 Description: Restore all menu parameters to their default values. Ignored. Ignored. Perform Process Low Calibration Performs a Low Calibration. The data field in the request message specifies the process. Make sure the prerequisite for the calibration is satisfied before issuing a calibration command. For instance, the RTD calibration command must only be used when the input sensor type is chosen as RTD or RTD w/ Decimal.

20 Request Data Fields: A 0 character ASCII representation of a numeric value specifying what to calibrate. 0 - Thermocouple - RTD, Resistive Thermal Device - Linear Response Data Field: Ignored. Command: Parameter #: 0 Description: Request Data Field: - RAS, Remote Analog Setpoint Perform Process High Calibration Performs a High Calibration. The data field in the request message specifies the process. Make sure the prerequisite for the calibration is satisfied before issuing a calibration command For instance, the RTD calibration command must only be used when the input sensor type is chosen as RTD or RTD w/ Decimal. A 0 character ASCII representation of a numeric value specifying what to calibrate. Command: Parameter #: 0 Description: Request Data Field: 0 - Thermocouple - RTD, Resistive Thermal Device - Linear - RAS, Remote Analog Setpoint Retrieve Display Retrieves the string currently displayed on the slave s display. The data field in the request message specifies which display and the data field in the response message contains the string. A 0 character ASCII representation of a numeric value specifying which display to retrieve data from. 0 - Lower Display - Upper Display Response Data Field: The ASCII string. Command: Parameter #: 0 Description: Request Data Field: Clear Latched Alarms Clear all latched alarms. Ignored. Response Data Field: Ignored.

21 Table. Error Codes Returned. Notes Code Description 0 No error. Framing error. Hardware error. Parity error. Bad character in the TYPE field. Bad message. Message cannot be understood. Bad checksum. The checksum received did not match the checksum of the message. Bad zone ID. Bad auxiliary command ID. The auxiliary command is not supported in this controller. Bad parameter ID. The parameter is not supported in this controller. A B C Bad data. Bad representation in the data field or data is out of range. Attempt to write to a read only parameter. Cannot write to a parameter because it s in use. 0

22 Notes WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of months from date of purchase. OMEGA Warranty adds an additional one () month grace period to the normal two () year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: () as a Basic Component under 0 CFR (NRC), used in or with any nuclear installation or activity; or () in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/ INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:. Purchase Order number under which the product was PURCHASED,. Model and serial number of the product under warranty, and. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:. Purchase Order number to cover the COST of the repair,. Model and serial number of the product, and. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 00 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

23 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers ph/conductivity ph Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial ph & Conductivity Equipment DATA ACQUISITION Data Acquisition & Engineering Software -Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters HEATERS Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment ph, Conductivity & Dissolved Oxygen Instruments M/0

User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion

User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info y = mx+b A Guide to Calibration and Unit Conversion OMB-457-0949 rev 1.0 OMEGAnet Online Service

More information

OME-SERIES DATA ACQUISITION CARDS

OME-SERIES DATA ACQUISITION CARDS User s Guide Shop online at www.omega.com e-mail: info@omega.com OME-SERIES DATA ACQUISITION CARDS Resource Checking User Manual OMEGAnet Online Service www.omega.com Internet e-mail info@omega.com Servicing

More information

MFT Series INTRODUCTION UNPACKING FERRULES

MFT Series INTRODUCTION UNPACKING FERRULES MFT Series Multiconductor Feedthroughs INSTRUCTION SHEET M0152/0103 Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info INTRODUCTION The OMEGA MFT multiconductor

More information

FTH SERIES HEATERS INSTALLATION, OPERATION AND MAINTENANCE

FTH SERIES HEATERS INSTALLATION, OPERATION AND MAINTENANCE MADE IN User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FTH SERIES Industrial Flow Through Heaters FTH SERIES HEATERS INSTALLATION, OPERATION AND

More information

User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. www.omega.com e-mail: info@omega.com

User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. www.omega.com e-mail: info@omega.com User s Guide Shop on line at www.omega.com e-mail: info@omega.com DPF700-A Analog Output Option Board for the DPF700 Meter Servicing North America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified

More information

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at User s Guide Software for OMB-DAQ-2416 Series and OM-USB Series Multi-function I/O USB Data Acquisition Modules Rev. Includes: InstaCal Installation application TracerDAQ Ready-to-run DAQ applications

More information

http://www.omega.com e-mail: info@omega.com

http://www.omega.com e-mail: info@omega.com http://www.omega.com e-mail: info@omega.com omega.com OMEGA TM OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com USA: ISO 9001 Certified One Omega Drive, Box 4047 Stamford,

More information

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info OSXL-100-PE Thermal Imaging Camera Enclosure Introduction Please read this manual completely

More information

User s Guide HHM-GRT300. 4 Wire Earth Resistance Tester. Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.

User s Guide HHM-GRT300. 4 Wire Earth Resistance Tester. Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual. User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info MADE IN CHINA HHM-GRT300 4 Wire Earth Resistance Tester OMEGAnet Online Service omega.com Internet

More information

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info MADE IN UNITED KINGDOM TL-WELD Thermocouple and Fine Wire Welder omega.com info@omega.com

More information

User s Guide. SW14 1 4 DIN Series and OSW Series. Shop online at. Rotary Selector Switches

User s Guide. SW14 1 4 DIN Series and OSW Series. Shop online at. Rotary Selector Switches MADE IN User s Guide Shop online at SW14 SERIES 1/4 DIN 96 x 96 mm (3.78") OSW SERIES 76 x 76 mm (3.0") 127 x 127 mm (5.0") omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info

More information

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info EWS-RH Relative Humidity/Temperature Transmitter omega.com info@omega.com Servicing North America:

More information

User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com e-mail: info@omega.com For latest product manuals: omegamanual.

User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com e-mail: info@omega.com For latest product manuals: omegamanual. MADE IN User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info HFS-3, HFS-4 Thin Film Flux Sensors OMEGAnet On-Line Service Internet e-mail omega.com

More information

Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info

Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info STCTX SERIES Industrial Thermocouple Connector/Transmitter INSTRUCTION SHEET M3935A/0810 Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info General Description

More information

User s Guide HHAQ-106. 6-IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

User s Guide HHAQ-106. 6-IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: omegamanual.info HHAQ-106 6-IN-1 Psychrometer With Enthalpy omega.com info@omega.com Servicing North America:

More information

User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors

User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors MADE IN User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info MTC SERIES Multi-Pin Thermocouple Connectors OMEGAnet On-Line Service omega.com Internet

More information

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info HHF81 Anemometer, Hygrometer, Light Meter, Thermometer omega.com info@omega.com Servicing North

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

User s Guide OM-USB-TC. 8 Channel Thermocouple Input USB Data Acquisition Module. Shop online at

User s Guide OM-USB-TC. 8 Channel Thermocouple Input USB Data Acquisition Module. Shop online at SM Extended Warranty Program User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info OM-USB-TC 8 Channel Thermocouple Input USB Data Acquisition Module

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual Dissolved Oxygen Meter Operator s Manual Newport Electronics, Inc. Additional products from Newport Electronics, Inc. THE NEW STANDARD FOR QUALITY Clock/Timers Counters Flow Sensors Frequency Meters Multimeters

More information

User s Guide WRS232-USB. Universal Wireless RS232 to USB Transceiver, WRS232 Wireless Transmitter, WUSB Wireless Receiver.

User s Guide WRS232-USB. Universal Wireless RS232 to USB Transceiver, WRS232 Wireless Transmitter, WUSB Wireless Receiver. MADE IN User s Guide Shop online at WUSB WIRELESS RECEIVER omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info WRS232 WIRELESS TRANSMITTER WRS232-USB Universal Wireless RS232

More information

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode: COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

More information

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Harris IRT Enterprises Digital Resistance Tester Model 5060-06XR

Harris IRT Enterprises Digital Resistance Tester Model 5060-06XR Harris IRT Enterprises Digital Resistance Tester Model 5060-06XR Specifications & Dimensions 2 Theory of Operation 3 Operator Controls & Connectors 4 Test Connections 5 Calibration Procedure 6-7 Options

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

Paragon Explorer Lite Communication Software

Paragon Explorer Lite Communication Software CU-111 APRIL 11, 2013 Paragon Explorer Lite Communication Software For Fireye Paragon Scanners using Windows XP DESCRIPTION Paragon Explorer Lite, is the basic PC based configuration tool for Paragon model

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

Load Cell Amplifier Module. Instruction Manual LCA210-000

Load Cell Amplifier Module. Instruction Manual LCA210-000 Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4

More information

DK40 Datasheet & Hardware manual Version 2

DK40 Datasheet & Hardware manual Version 2 DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...

More information

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

INTMOD485-LH Protocol Converter

INTMOD485-LH Protocol Converter For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

F2400 FOM II Series Fiber Optic Modem Technical Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data

More information

Advanced Data Capture and Control Systems

Advanced Data Capture and Control Systems Advanced Data Capture and Control Systems Tronisoft Limited Email: sales@tronisoft.com Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document

More information

AN2680 Application note

AN2680 Application note Application note Fan speed controller based on STDS75 or STLM75 digital temperature sensor and ST72651AR6 MCU Introduction This application note describes the method of defining the system for regulating

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510 User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Brushless DC Motor Controller Product Specification Assembly 025F0129

Brushless DC Motor Controller Product Specification Assembly 025F0129 Brushless DC Motor Controller Product Specification Assembly 025F0129 September 16, 2009 025F0129 ST B Brushless DC Motor Controller Data Sheet Page 1 Revision History ECN # Date Rev Description By 07058

More information

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

User s Guide OM-MICROLITE-8 AND OM-MICROLITE-16 DATA LOGGERS AND OM-MICROLAB-LITE SOFTWARE. Shop online at

User s Guide OM-MICROLITE-8 AND OM-MICROLITE-16 DATA LOGGERS AND OM-MICROLAB-LITE SOFTWARE. Shop online at User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info OM-MICROLITE-8 AND OM-MICROLITE-16 DATA LOGGERS AND OM-MICROLAB-LITE SOFTWARE OMEGAnet Online Service

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity SMS Alert Controller Version 7 [Windows XP/Vista/7] GSMS THR / GSMS THP Revision 110507 [Version 2.2.14A] ~ 1 ~ SMS Alarm Messenger Version 7 [Windows XP/Vista/7] SMS Pro series

More information

BACnet Automation Interface Module (Network Version)

BACnet Automation Interface Module (Network Version) Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP

More information

Rev 06 1211. GSM base station. Installation instructions

Rev 06 1211. GSM base station. Installation instructions Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard

More information

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Model 5511 Filler Controller User s Manual Version 1.1 October 2011 Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

TTL to RS232 Adapter User Guide

TTL to RS232 Adapter User Guide TTL to RS232 Adapter User Guide Revision D March 28, 2011 Document Part Number GC-800-313d Copyright and Trademark Copyright 2006-2011, Grid Connect, Inc. All rights reserved. No part of this manual may

More information

Table of Contents. Creating a VC1000 Network... 3

Table of Contents. Creating a VC1000 Network... 3 2 Table of Contents Creating a VC1000 Network... 3 Topology... 3 Unit ddressing... 4 Terminating Resistors... 5 Shielding... 5 Interconnecting the common... 6 ias Resistors... 6 VC1000 Hardware Configuration...

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

C-Tech-10 Operation Manual

C-Tech-10 Operation Manual C-Tech-10 Operation Manual Project: SATS Model: SATS Serial #: SATS Job#: Notice This document contains information protected by copyright. All rights are reserved. The owner of the equipment for which

More information

Digital and Analog I/O

Digital and Analog I/O 70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external

More information

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It

More information

Modbus Communications for PanelView Terminals

Modbus Communications for PanelView Terminals User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document

More information

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5

More information

Single channel data transceiver module WIZ2-434

Single channel data transceiver module WIZ2-434 Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules

More information

Original instructions Tina 3A/Aps Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information Description Features The S112-X is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. The circuit is composed of one input IR LED with a series limiting resistor

More information

DCX300 - DCX400 - DCX600

DCX300 - DCX400 - DCX600 Ph: 541-476-3565 Fax: 541-476-3566 DCX300 - DCX400 - DCX SEPARATELY EXCITED DC MOTOR CONROLLERS Alltrax motor controllers are designed to work with various golf cars from different manufacturers. Use the

More information

SingleNet Single Cable Control System

SingleNet Single Cable Control System Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls

More information

DVI to Analog Converter

DVI to Analog Converter DVI to Analog Converter Quick Installation Guide 10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM LIMITED WARRANTY Rose Electronics warrants the DVI to VGA converter to be

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS ddcwp_manual_gb_revisions.ai 10/23/06 Page 1 Date: Station 1 2 3 4 5 6 7 8 CUSTOM WATERING PLAN 3 Program Controller Description Program A Program B Program C Duration Duration Duration DDC WP Series Waterproof

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

InHome Water Leak Detection Package

InHome Water Leak Detection Package InHome Water Leak Detection Package For Model Numbers ILD10A-L and ILD10A-B Installation Guide / Wiring Diagram For Creating Water Leak Detection-based Events with Line-Powered or Battery-Powered Sensors

More information

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM XE0402LCC January 2007 Miniature Surface-Mount DAA for Audio or Data Transfer Description The XE0402LCC supplies a complete telephone line interface or DAA (Data Access Arrangement) in a miniature, surface-mount

More information

FAQ s on Siemens Magmeters

FAQ s on Siemens Magmeters FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd. Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X

More information

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03 MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

Temp. & humidity Transmitter Instructions

Temp. & humidity Transmitter Instructions Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity

More information

TAC I/NETTM MR-AHU-HP. Application Specific Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms

More information

Comfort Control Relay Panel (CCRP)

Comfort Control Relay Panel (CCRP) CCRP9 "Commitment to Innovation" OPERATION & INSTALLATION GUIDE FOR Comfort Control Panel (CCRP) Off-Peak System Control 9 Pole CCRP 4 Pole CCRP (Applicable to Software Version 14.0-14.9) "Manufactured

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

User Manual IC-485AI 2002-09-27

User Manual IC-485AI 2002-09-27 User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable

More information

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0

More information

Ground Resistance Clamp-On Tester

Ground Resistance Clamp-On Tester User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one

More information

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205] Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205] Users Manual Robokits India info@robokits.co.in http://www.robokitsworld.com Page 1 Bluetooth + USB 16 Servo Controller is used to control up to

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

S4000TH HART. HART Communication Manual

S4000TH HART. HART Communication Manual HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Single Port T1/E1 Tap

Single Port T1/E1 Tap Single Port T1/E1 Tap Model 2 CUSTOMER SUPPORT INFORMATION To order or for a technical information support: Phone: +33 3 88 10 18 30 or Fax: +33 3 88 10 18 35 Mail order: COMCRAFT 2, rue de la Mairie 67203

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

A RF18 Remote control receiver MODULE

A RF18 Remote control receiver MODULE A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject

More information

LCD5500Z / PKP-LCD v3.x Installation Instructions

LCD5500Z / PKP-LCD v3.x Installation Instructions LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up

More information

TP32MTT.03 TP32MTT.03.1. [ GB ] Probes for soil thermal profile measurement

TP32MTT.03 TP32MTT.03.1. [ GB ] Probes for soil thermal profile measurement TP32MTT.03 [ GB ] Probes for soil thermal profile measurement [ GB ] [ GB ] Description Temperature measurement at 7 levels (TP32MTT.03) or 6 levels () In accordance with the requirements of the World

More information

Old Company Name in Catalogs and Other Documents

Old Company Name in Catalogs and Other Documents To our customers, Old Company Name in Catalogs and Other Documents On April 1 st, 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took

More information

Installation and Operation Guide for PD4100 Series Power Control Centers

Installation and Operation Guide for PD4100 Series Power Control Centers Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as

More information

INSTRUCTION MANUAL 2044-01 T1 TO RS422 INTERFACE

INSTRUCTION MANUAL 2044-01 T1 TO RS422 INTERFACE INSTRUCTION MANUAL 044-0 T TO RS4 INTERFACE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form without

More information

User Manual. AS-Interface Programmer

User Manual. AS-Interface Programmer AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.

More information

PPM Users Manual Signature Software 01-12-00

PPM Users Manual Signature Software 01-12-00 PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower

More information