INVERTER SPLIT TYPE - DUCTLESS MINI SPLIT SYSTEM WYE SERIES HEAT PUMPS

Size: px
Start display at page:

Download "INVERTER SPLIT TYPE - DUCTLESS MINI SPLIT SYSTEM WYE SERIES HEAT PUMPS"

Transcription

1 Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT TYPE - DUCTLESS MINI SPLIT SYSTEM WYE SERIES HEAT PUMPS The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. CS156U-BP11D Read This Manual Keep this manual where the operator can easily find them.inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service.

2 CNTENTS SAFETY PRECAUTINS Warning...3 Caution...4. NAMES F PARTS Indoor unit outdoor unit...5 Indication lamp...5 PERATING INSTRUCTINS Special functions...6 perating temperature...7 Manual operation...7 Airflow direction control...8 How the air conditioner works...9 CARE AND MAINTENANCE Before maintenance Cleaning the unit...10 Cleaning the air filter and air freshening filter...10 Replacement of the air filter and air freshening filter...11 Preparation for extended non-operation...11 Pre-season inspection...11 When using this air conditioner in the European countries, please read the following information: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. DISPSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user. B) When buying a new product, the retailer will take back the old product at least free of charge. C) The manufacturer will take back the old appliance for disposal at least free of charge to the user. D) As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain. TRUBLESHTING TIPS Normal function of the air conditioner...12 Troubleshooting guide

3 SAFETY PRECAUTINS SAFETY PRECAUTINS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. CAUTIN WARNING CAUTIN This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to property. Meanings of symbols used in this manual are as shown below. Strictly prohibited. Be sure to follow the instructions. Do not extend the cable and never use multiple plugs. A poor electrical connection, poor insulation or voltage which is higher than permitted can cause fire. Do not expose your body directly to the cool air for prolonged period. Never poke fingers, sticks or other objects in the air inlet and outlet vents. Never attempt to repair, relocate, modify the air conditioner yourself. Always contact your service partner if it requires. Never pull the plug out by pulling on the cable. Hold the plug firmly and pull it out of the plug socket, otherwise there is a risk of damaging the cable. Do not operate your air conditioner in a wet room such as a bathroom or laundry room. WARNING Remove all dirt from the power plug and plug it firmly. Soiled plugs can cause fire or an electric shock. In the event of any abnormalities such as smell of burning, immediately switch off the device and pull the plug. Contact your service partner. Always switch off the device and pull the plug before you start to clean it. Use specified power cord. Contact the authorized installer for installation of this unit. Contact an authorized service technician for repair or maintenance of this unit. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the air conditioner. Never actuate any switches with a wet hand. It may cause an electric shock. Never use the device for any other purpose than the intended use. Never place food, precision instruments, plants, animals, paint, etc. on the unit. Do not expose plants or animals directly to the air flow. Never clean the air conditioner with water. Never use combustible cleaning agents as these could cause a fire or deformation. Never place any burning objects close to the device if they could be directly affected by the emitted air. Never step onto the outdoor device and never place anything on it. Never use an unsteady or rusty base. Never install the air conditioner in places where combustible gas can be emitted. Emmitted gas may collect and cause an explosion. Never allow the air conditioner to run for too long with the doors or windows open, or if the humidity is very high. If the air conditioner is to be used in conjunction with other heaters, the air should be refreshed periodically, otherwise there is a risk of lack of oxygen. Always pull out the power plug if the unit is not going to be used for any lengthy period of time. Collections of dust can cause fire. Always switch off the air conditioner and pull out the power plug during a storm. Electrical parts may get damaged. Check that the drainage line is correctly connected. If not, water will escape. Check that the condensation water can run off unhindered. It may cause water damage if the condensation water cannot run off properly. The air conditoner must be earthed in accordance with the local codes. For electrical safety purposes we recommend that you install an earthleakage circuit-breaker. If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similary qualified persons in order to avoid a hazard. 3 4

4 NAMES F PARTS PERATING INSTRUCTINS Special functions Air inlet(side) Air inlet(rear) Air outlet Signal receiver (A) Signal receiver (B) Names of parts Indoor unit 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6. Vertical air flow louver(inside) 7. Display panel utdoor unit 8. Connecting pipe 9. Connecting cable 10. Stop valve NTE: All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit you purchased may be slight different on front panel and display window.the actual shape shall prevail. Indication lamp PERATIN indication lamp This lamp illuminates when the air conditioner is in operation. TIMER indication lamp Lights up during Timer operation. DEFRST indication lamp (Enabled on cooling & heating models only): Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation. Refrigerant Leakage Detection With this new technology, the dipsplay area will appear EC and the indication lamps continue flashing when the outdoor unit detects refrigerant leakage. Louver Angle Memory Function(optional): Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will memorize the boundry of safety angle. In the following circumstances, it will return to standard angle: 1) pressing the manual control button, 2)unplug and then plug in the machine. So we strongly suggest that the open angle of the horizontal louver should not be set too small, in case the condensed water forms and drops from the horizontal louver. SELF CLEAN function(ptional) Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation. The unit will operate as following sequence : FAN NLY mode at Low fan speed--heating operation with LW fan speed(applicable to cooling & heating modles only) ---FAN NLY operation--stop peration---turn off. Note: This function is only available under CL(AUT CL, FRCED CL) and DRY mode. Before select the function, it is recommended to run the air conditioner under Cooling operation for about half an hour. nce the Self Clean function is activated, all TIMER setting will be cancelled. During Self Clean operation, when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit automatically. CLEAN AIR function(on some models) Improving the quality of indoor air is one of the purposes of an air conditioner. This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific configuration of the model). With the anions generated by Ionizer, the air circulation of the air conditioner fills the room with refreshing, natural and healthy air. The Plasma Dust Collector generates a high voltage ionization zone, through which the air is converted to plasma. Inside the air most of the dust, smoke, and pollen particles are captured by the electrostatic filter.,, Temperature indicator Displays the temperature settings when the air conditioner is operational. Displays the malfunction code. Anti-mildew function(ptional) When turns off the unit on CL, DRY, AUT (Cool) mode, the air conditioner will continue operating for about 7-10 minutes (depending on models) at LW fan speed. If turns off on HEAT mode, the unit will continue operating for about 30 seconds at LW fan speed. This will help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew. Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off. 5 6

5 PERATING INSTRUCTINS NTE: This manual does not include Remote Controller perations, see the <<Remote Controller Instruction>> packed with the unit for details. perating temperature Mode Temperature Room temperature utdoor temperature NTE: 1. ptimum performance will be achieved within these operating temperatures.if air conditioner is used outside of the above conditions, certain safety protection features might come into operation and cause the unit to function abnormally. 2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 80%), condensed water may drip out of the unit. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode. Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to guarantee it running smoothly. Manual operation Units are equipped with a switch to run emergency operation mode. It can be accessed by opening the front panel. This switch is used for manual operation in case the remote controller fails to work or maintenance necessary. Manual switch Manual switch AUT/CL AUT/CL (1) (2) Cooling operation Heating operation Drying operation 17 C~32 C 0 C~30 C (62 F~90 F) (32 F~86 F) For the models with low temperature cooling system Suspension bars NTE: The unit must be turned off before operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off. 1 pen and lift the front panel up to an angle until it remains fixed with a clicking sound. For some models, please use suspension bars to prop up the panel. 2 ne press of the manual control switch will lead to the forced AUT operation. If press the switch twice within five seconds, the unit will operate under forced CL operation. 3 Close the panel firmly to its original position. 10 C~32 C (50 F~90 F) CAUTIN: This switch is used for testing purposes only. You had better not choose it. To restore the remote controller operation, use the remote controller directly. Airflow direction control Range Deflector rod Range PERATING INSTRUCTINS Adjust the air flow direction properly, otherwise it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow(up--down) direction Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction. The horizontal louver can be moved at a range of 6 for each press, or swing up and down automatically. Please refer to the REMTE,, CNTRLLER PERATIN MANUAL for details. To set the horizontal air flow direction (left - right) Move the deflector rod manually to adjust the air flow in the direction you prefer. IMPRTANT:Do not put your fingers into the panel of blower and suction side.the high-speed fan inside may cause danger. CAUTIN Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. therwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds. pen angle of the horizontal louver should not be set too small, as CLING or HEATING performance may be impaired due to too restricted air flow area. Do not move the horizontal louver manually, otherwise the horizontal louver will be out of sync. Please cease operating, unplug power for a few seconds,then restart the air conditioner.,, 7 8

6 PERATING INSTRUCTINS CARE AND MAINTENANCE How the air conditioner works SLEEP operation Set Temperature Set Temperature 1 hour SLEEP operation 1 hour Cooling 1 hour 1 hour Heating 7 hours timer off 7 hours timer off AUT operation When you set the air conditioner in AUT mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on set temperature and the room temperature. The air conditioner will control room temperature automatically to the temperature point you set. If you feel uncomfortable in the AUT mode, you can set your desired temperature. SLEEP operation When you push SLEEP button on remote controller during cooling, heating(cooling & heating models only), or AUT operation, the air conditioner will automatically increase (cooling) or decrease (heating) per hour for the first 2 hours, then hold steadily for the next 5 hours, after that it will switch off. This mode saves you energy and brings you comfort at night. DRYING operation The fan speed will be automatically controlled under dry operation. During the dry operation, if the room temperature is lower than 10 C(50 F), the compressor stops operation and restarts until the room temperature is above 12 C(54 F). Care and Maintenance Filter Handle Before mainatenance Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NTE: Power supply must be disconnectd before cleaning the indoor unit. CAUTINS A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit. Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform. Never use water hotter than 40 C/104 F to clean the front panel, it could cause deformation of discoloration. Cleaning the unit wipe the unit with a soft dry cloth only. If the unit is very dirty, wipe it with a cloth soaked in warm water. ptimal operation To achieve optimal performance, please note the following: Adjust the air flow direction correctly so that it is not forwards people. Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. Close doors and windows on CL or HEAT modes, or performance may be reduced. Use TIMER N button on the remote controller to select a time you want to start your air conditioner. Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Clean the air filter periodically, otherwise cooling or heating performance may be reduced. Do not operate unit with horizontal louvre in closed position. Air freshening filter Cleaning the air filter and air freshening filter A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks. 1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.for some models, please use suspension bars to prop up the panel. 2. Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder, then pull it downwards. 3. Remove the AIR FILTER from the indoor unit. Clean the AIR FILTER once two weeks. Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place. 4. Remove the Air Freshening Filter from its supporting frame (on some models).. Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool.place. 9 10

7 CARE AND MAINTENANCE TRUBLESHTING TIPS 5. Install the air freshening filter back into position. 6. Insert the upper portion of air filter back into the unit, taking care that the left and right edges line up correctly and place filter into position. Replacement of air filter and air freshening filter 1. Remove the air filter. 2. Remove the air freshening filter. 3. Install a new air freshening filter. 4. Reinstall the air filter and securely close the front panel. Idle the unit If you plan to idle the unit for a long time, perform the following: (1) Clean the indoor unit and filters. (2) perate the fan for about half a day to dry the inside of the unit. (3) Stop the air conditioner and disconnect power. (4) Remove the batteries from the remote controller. The outdoor unit requires periodic maintenance and cleaning. Do not attempt to do this yourself. Contact your dealer or service provider. Checks before operation Check that the wiring is not broken off or disconnected. Clean the indoor unit and filters. Check that the air filter is installed. Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time. Caution Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. When cleaning the unit, first make sure that the power and circuit breaker are turned off. Do not wash air filter with hot water at more than 40 C. Shake off moisture completely and dry /104 F it in the shade. Do not expose it directly to the sun, it may shrink. Normal function of the air conditioner The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3-4 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just started. B) Defrosting. C) Low temperature heating. The indoor or outdoor fan stop running when defrosting (Cooling and heating models only). Defrosting (Cooling and heating models only) Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner. During this condition air conditioner will stop heating operation and start defrosting automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost built up on the outdoor unit. 2. A white mist coming out from the indoor unit A white mist may generate due to a large temperature difference between air inlet and air outlet on CL mode in an indoor environment that has a high relative humidity. A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting. 3. Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running. It is the sound of the refrigerant flowing or coming to a stop. You can also hear a low "squeak" sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing. A noise may be heard due to louver restoring to its original position when power is turned on. 4. Dust is blown out from the indoor unit. This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit. 5. A peculiar smell comes out from the indoor unit. This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke. 6. The air conditioner turns to FAN only mode from CL or HEAT (For cooling and heating models only) mode. When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on CL mode or falls on HEAT mode (For cooling and heating models only) to the set point

8 TRUBLESHTING TIPS 7. The air conditioner runs Anti-mildew function after turning off the unit. When turning off the unit under CL(AUT CL, FRCED CL) and DRY mode, the air conditioner will run Anti-mildew function for 7-10 minutes, if turns off on HEAT mode, the unit will continue operating for about 30 seconds at LW fan speed, then stop the operation and turn off the unit automatically. 8. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 9. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air conditioner, we suggest you use a supplementary heating device. Troubleshooting guide Trouble PERATIN(RUN) indicator or other indicators continue flashing. If one of the following code appears on the display area : E0,E1,E2,E3...or P0,P1,P2, P3..., F1,F2,F3... Fuse blows frequently or circuit breaker trips frequently. ther objects or water fall into the air conditioner. The remote controller won't work or works abnormally. TRUBLESHTING TIPS The unit may stop operation or continue to run in a safety condition(depending on models). Waiting for about 10 minutes, the fault may be recovered automatically, if not, disconnect the power and then connect it in again. If the problem still exists, disconnect the power and contact the nearest customer service center. Stop the air conditioner immediately, disconnect the power and contact the nearest customer service center. 10. Auto-restart function Power failure during operation will stop the unit completely. For the unit without Auto-restart feature, when the power restores, the PERATIN indicator on the indoor unit starts flashing. To restart the operation, push the N/FF button on the remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function. Malfunctions Unit does not start Power cut Cause Unit may have become Unplugged. Fuse may have blown. What should be done? Wait for power to be restored. Check that plug is securely in wall receptacle. Replace the fuse. Battery in Remote controller may have been exhausted. Replace the battery. Unit not cooling Inappropriate temperature or heating setting. (Cooling/ heating models only) room very well while air flowing out from the air conditioner The time you have set with timer is incorrect. Air filter is blocked. Doors or Windows are open. Air inlet or outlet of indoor or outdoor unit has been blocked. Compressor 3 or 4 minutes protection has been activated. Wait or cancel timer setting. Set temperature correctly. For detailed method please refer to " Using remote control " section. Clean the air filter. Close the doors or windows. Clear obstructions away first, then restart the unit. Wait. If the trouble has not been corrected, please contact a local dealer or the nearest customer service center. Be sure to inform them of the detailed malfunctions and unit model number. 13 Notes: Do not attempt to repair the unit yourself. Always consult an authorized service provider. 14

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24 Wall Mounted Unit CONTENTS SAFETY PRECAUTIONS Warning...3 Caution...4. NAMES OF PARTS Indoor unit......5 outdoor unit...5 Indication lamp...5 OPERATING

More information

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT-TYPE RM AIR CNDITINER The design and specifications are subject to change without prior

More information

Inverter Single Zone Ductless Mini Split Heat Pump

Inverter Single Zone Ductless Mini Split Heat Pump WNER S MANUAL Inverter Single Zone Ductless Mini Split Heat Pump VMH 30/36 Series Version C Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com wner s Manual

More information

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference. Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT - TYPE RM AIR CNDITINER Read This Manual Inside you will find many helpful hints on how to use

More information

Split Type Room Air Conditioner. KSWM units

Split Type Room Air Conditioner. KSWM units OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how to

More information

Room Air Conditioners

Room Air Conditioners User Manual Room Air Conditioners R410A Split Type Y Series DC INVERTER ECO940SD ECO120SD ECO1840SD Please read this installation manual completely before installing the product. When the power cord is

More information

R410A SPLIT SERIES DC INVERTER

R410A SPLIT SERIES DC INVERTER R40A SPLIT SERIES DC INVERTER Models ECO905SINV ECO205SINV ECO805SINV Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative

More information

Instruction manual for Firstline FCS12000CH

Instruction manual for Firstline FCS12000CH Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of

More information

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

OPTIONAL SLENDER REMOTE CONTROL

OPTIONAL SLENDER REMOTE CONTROL DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with

More information

Split Air Conditioner

Split Air Conditioner Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1

More information

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto

More information

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Use and Care Manual. Model CPA12KH AIR CONDITIONER Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FT50GAVEA FT60GAVEA FTY50GAVA FTY60GAVA ENGLISH ESPAÑOL TURKISH CONTENTS READ BEFORE OPERATION Safety Precautions... Names of Parts Indoor unit, Opening

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place

More information

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FT50BSG FT60BSG CONTENTS READ BEFORE OPERATION Safety Precautions... 2 Names of Parts Indoor unit, Opening the front grille... 5 Remote controller, Outdoor

More information

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-60YHA/RAC-60YHA OUTDOOR UNIT INDOOR UNIT RAC-60YHA RAS-60YHA Instruction manual Page 1~26 To obtain the best performance and ensure years of

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

AIR CONDITIONER (SPLIT TYPE)

AIR CONDITIONER (SPLIT TYPE) OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use ENGLISH EN Indoor Unit RAS-07PKVP-E RAS-10PKVP-E RAS-13PKVP-E RAS-16PKVP-E RAS-18PKVP-E RAS-07PKVP-ND RAS-10PKVP-ND RAS-13PKVP-ND RAS-16PKVP-ND

More information

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)

More information

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate

More information

LG Multi Type Air Conditioner

LG Multi Type Air Conditioner LG Multi Type Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3

More information

Owner s Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E. Model name:

Owner s Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E. Model name: AIR CONDITIONER (SPLIT TYPE) Indoor Unit Not accessible to the general public Model name: 4-way Air Discharge Cassette Type RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E Air conditioner (Split

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg. ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Room Air Conditioner P/NO : 3828A20434H www.lg.com

More information

Meaco 30L and Meaco 40L dehumidifier instruction manual

Meaco 30L and Meaco 40L dehumidifier instruction manual Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS

More information

LG Room Air Conditioner OWNER'S MANUAL

LG Room Air Conditioner OWNER'S MANUAL website http://www.lg.ca LG Room Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN

More information

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL website http://www.lgservice.com LG Floor Standing-Type Air Conditioner OWNER'S MANUAL LG ENGLISH FRANÇAIS ITALIANO ESPAÑOL ESPAÑOL FRANÇAIS DEUTSCH IMPORTANT Please read this owner's manual carefully

More information

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER G Series Cooling A O W N E R S MANUAL Thank you for selecting Carrier! You can be justifiably proud of your purchase because the same pride in craftsmanship

More information

DAIKIN ROOM AIR CONDITIONER FTKD50BSG FTKD60BSG FTKD71BSG MODELS. Operation Manual

DAIKIN ROOM AIR CONDITIONER FTKD50BSG FTKD60BSG FTKD71BSG MODELS. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTKD50BSG FTKD60BSG FTKD7BSG CONTENTS READ BEFORE OPERATION Safety Precautions... Not for multi System... 4 Names of Parts Indoor unit, Opening the front

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

Split Air Conditioner

Split Air Conditioner Change for Life Split Air Conditioner Owner's Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD

More information

Important Safeguards

Important Safeguards Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES

RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3.

More information

All about the Use &Care

All about the Use &Care All about the Use &Care of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352 66129904886 (June 2009)

More information

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with

More information

DUCT TYPE AIR CONDITIONER

DUCT TYPE AIR CONDITIONER OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch

More information

Operating Instructions

Operating Instructions Operating Instructions Air Conditioner Model No. Indoor Unit CS-S9PKR CS-S12PKR CS-S18PKR CS-S24PKR CS-S28PKR Outdoor Unit CU-S9PKR CU-S12PKR CU-S18PKR CU-S24PKR CU-S28PKR Operating Instructions Air Conditioner

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

Reverse Cycle Inverter Split System Air Conditioner

Reverse Cycle Inverter Split System Air Conditioner Reverse Cycle Inverter Split System Air Conditioner Model Number STR-23RSJAIF INSTRUCTION MANUAL 1300 886 649 info@tempo.org Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 08 Product

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT TEMPORARY SWITCH SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-50FH7/RAC-50YH7 ENGLISH DEUTSCH FRANÇAIS INDOOR UNIT ITALIANO HITACHI RAS-50FH7 OUTDOOR UNIT DC INVERTER ESPAÑOL PORTUGUÊS

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg. OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL67657205 www.lg.com ITALIANO ESPAÑOL FRANÇAIS

More information

2-SLICE COOL TOUCH TOASTER

2-SLICE COOL TOUCH TOASTER 2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

SAFEGUARDING THE ENVIRONMENT

SAFEGUARDING THE ENVIRONMENT SAFETY PRECAUTIONS Do not install the appliance if it is connected to the power supply. The Installation and service/repair must be performed by a qualified technician, in compliance with the producer's

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL WHAT IS AN ECO AIR COOLER? The ECO AIR COOLER uses evaporative cooling to provide an airflow that is cooler than the

More information

OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV

OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV SPLIT-TYPE AIR CONDITIONERS OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV For customers Thank you very much for purchasing this Mitsubishi room air conditioner. To use this

More information

Operation Manual MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B DAIKIN ROOM AIR CONDITIONER. English. Deutsch. Français. Nederlands. Español.

Operation Manual MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B DAIKIN ROOM AIR CONDITIONER. English. Deutsch. Français. Nederlands. Español. DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B English Deutsch Français Nederlands Español Italiano!""#$%&Ü Portugues!ó""ê#$ Türkçe CONTENTS READ BEFORE OPERATION

More information

The figures in this manual may be different with the material objects, please refer to the material objects for reference.

The figures in this manual may be different with the material objects, please refer to the material objects for reference. CONTENTS Operation and maintenance Notices for operation Notices for use Names and functions of each part Operation of wireless remote control Emergency operation Clean and care Troubleshooting Installation

More information

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL EVAPORATIVE AIR COOLER INSTRUCTION MANUAL Model: SF-614P Please read this manual thoroughly before using this product. Keep in a safe place for future reference. CONTENTS A. PRODUCT INTRODUCTION 2 B. TECHNICAL

More information

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-18QH8(W) RAK-25QH8(W) RAK-35QH8(W) RAK-50QH8(W) RAK-18QH8(B) RAK-25QH8(B) RAK-35QH8(B) RAK-50QH8(B)

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-18QH8(W) RAK-25QH8(W) RAK-35QH8(W) RAK-50QH8(W) RAK-18QH8(B) RAK-25QH8(B) RAK-35QH8(B) RAK-50QH8(B) SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-18QH8(W) RAK-25QH8(W) RAK-35QH8(W) RAK-50QH8(W) RAK-18QH8(B) RAK-25QH8(B) RAK-35QH8(B) RAK-50QH8(B) INDOOR UNIT ESPAÑOL ITALIANO FRANÇAIS DEUTSCH ENGLISH

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. FRANCAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED LSN-LSU-90-120HYV Applied Models : AS-W093MMM9

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

VACUUM CLEANER INSTRUCTION MANUAL

VACUUM CLEANER INSTRUCTION MANUAL VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,

More information

LG Room Air Conditioner OWNER'S MANUAL

LG Room Air Conditioner OWNER'S MANUAL Visit us at http://www.lgservice.com LG Room Air Conditioner OWNER'S MANUAL Dear Owner Thank you for installing LG air conditioner. Your best choice guarantees you a great performance and service to make

More information

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current. Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg. SVENSKA NORSK SUOMI DANSK OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL67641301 www.lg.com

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to

More information

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap

More information

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

To suit Daikin FDY F Series and FD F Series. (and other models incorporating BRC1B62/52 Remote Controller) OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank

More information

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWC09AB-D3DNA2D GWC12AB-D3DNA2D GWC18AC-D3DNA2D GWC24AC-D3DNA2D GWH09AB-D3DNA2D GWH12AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

More information

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL63288101 www.lge.com

More information

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725 Read this manual thoroughly before using and save it for future reference Purchase MAP capsules at Harvey Norman stores nationwide

More information

RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E

RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E AIR CONDITIONER (SPLIT TYPE) Owner s Manual Indoor Unit Model name: For commercial use 4-way Cassette Type RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E Owner s Manual English

More information

OPERATION MANUAL. and System air conditioner RXYSQ4P8V1B RXYSQ5P8V1B RXYSQ6P8V1B RXYSQ4P8Y1B RXYSQ5P8Y1B RXYSQ6P8Y1B

OPERATION MANUAL. and System air conditioner RXYSQ4P8V1B RXYSQ5P8V1B RXYSQ6P8V1B RXYSQ4P8Y1B RXYSQ5P8Y1B RXYSQ6P8Y1B OPERATION MANUAL and System air conditioner RXYSQP8VB RXYSQP8VB RXYSQ6P8VB RXYSQP8YB RXYSQP8YB RXYSQ6P8YB RXYSQPA7VB RXYSQPA7VB RXYSQ6PA7VB RXYSQPA7YB RXYSQPA7YB RXYSQ6PA7YB RXYQP9WB RXYQ8P9WB RXYQ0P9WB

More information

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0 VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully

More information

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual Owner s Manual Remote controller with weekly timer RBC-AMS41E Owner s Manual Remote controller Mode d emploi Télécommande Bedienungsanleitung Fernbedienung Manuale di istruzioni Telecomando Manual del

More information

Troubleshooting Your Refrigerator

Troubleshooting Your Refrigerator Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.

More information

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase User s Guide Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase of the FLAVORCHEF cooking system, which will provide you with healthy and tasty meals for

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lge.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lge. ENGLISH OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : 5400554301 Rev.: c www.lge.com Air Conditioner

More information

AIR CONDITIONER Duct Type OPERATING MANUAL

AIR CONDITIONER Duct Type OPERATING MANUAL AIR CONDITIONER Duct Type OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379460 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 3 NAME OF PARTS... 4 PREPARATORY OPERATION... 5

More information

Taurus Series YORK Window Air Conditioners

Taurus Series YORK Window Air Conditioners Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,

More information

LG Wireless Remote Controller

LG Wireless Remote Controller Visit us at : http://www.lgservice.com LG Wireless Remote Controller Owner's & Installation Manual Models: PQWRHSF0 PQWRCSF0 LG ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH IMPORTANT Please read this installation

More information

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment) Contents PREPARATION Safety Precautions... 3 Name of Each Part... 8 Remote Control Buttons and Display... 10 Inserting the Remote Control Batteries... 11 Getting Started... 12 OPERATION Selecting Auto

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

Please read and keep these instructions. Run water through your machine before first use

Please read and keep these instructions. Run water through your machine before first use 47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,

More information

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8 Contents PREPARING YOUR AIR CONDITIONER Safety Precautions..................................................... 3 View of the Indoor unit................................................ 8 RECOMMENDATIONS

More information

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

AIR CONDITIONER OWNER S MANUAL. ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πãõ PORTUGUÊS NEDERLANDS

AIR CONDITIONER OWNER S MANUAL. ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πãõ PORTUGUÊS NEDERLANDS OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. Type : Floor Standing Type(Console) www.lg.com ENGLISH ITALIANO ESPAÑOL FRANÇAIS

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting

More information