NPort Express User s Guide
|
|
|
- Horatio Powell
- 9 years ago
- Views:
Transcription
1 NPort Express User s Guide Ethernet Modem Advanced RAW Connection (TCP/UDP Support) With Data packing Moxa Technologies Co., Ltd. Tel: Fax: [email protected]
2
3 NPort Express Ethernet Modem User s Guide Introduction NPort Express s new Ethernet Modem operation mode is designed to provide true modem emulation, in which NPort Express emulates a regular serial modem, accepting AT commands for dial-in/out service and then transparently passing raw data in/out after the user initiates the Ethernet Modem mode. After a connection is established, NPort Express acts as a gateway between the serial line and Ethernet LAN, making it possible for raw RS-232/422/485 data to travel across a local LAN. After receiving raw serial data, NPort Express will prefix and postfix a TCP/IP header and trailer, and then send it out to the Ethernet medium. Once the control host receives the TCP/IP data frame, the NOS (Network Operating System) recovers the raw data by decoding the TCP/IP header and trailer. The user can easily capture the raw serial data from the Ethernet medium using Telnet or some customized TCP/IP socket program, providing an ideal long-distance serial data transmission solution between host and serial device. Application Architecture Two typical applications: (1) (2) Note: If the DCD signal for carrier detection is required, you will need to use a cable to connect NPort Express s serial port to your device/pc, as shown here: 1/19
4 NPort Express Configuration Note: This function is available in firmware version or above for NPort Express 1. Enter NPort Express s configuration screen using either Telnet over a LAN, or Moxa PComm Terminal Emulator via NPort Express s RS-232 Console port. 2. Open the serverconfig screen, and then change the Operating Mode to [Ethernet Modem]. 3. Open the Serialport screen and set TCP port no. and Destination IP. NOTES: 1. TCP port no. has default value = Only the device with IP set to Destination IP will be allowed access or leave empty for all devices 4. Restart NPort Express s operating system. Using Ethernet Modem [Dial-in] NPort Express listens for a TCP/IP connection request from the remote Ethernet modem or host. NPort Express s response depends on the ATS0 value, as outlined below. ATS0=0 (default): NPort Express will temporarily accept the TCP connection and then send the ATS0>=1: [Dial-out] 2/19 RING signal out through the serial port. The serial controller must reply with ATA within 2.5 seconds to accept the connection request, after which NPort Express enters data mode. If no ATA command is received, NPort Express will disconnect after sending three RING signals. NPort Express will accept the TCP connection immediately and then send the CONNECT <baud> command to the serial port, in which <baud> represents the baud rate of NPort Express s serial port. After that, NPort Express immediately enters data mode. NPort Express accepts the AT command ATD <IP>:<TCP port> from the serial port and then requests a TCP connection from the remote Ethernet Modem or PC. This is where <IP> is the IP address of the remote Ethernet modem or PC, and <TCP port> is the TCP port number of the remote Ethernet modem or PC. Once the remote box accepts this TCP connection, NPort Express will send out the CONNECT <baud> signal via the serial port and then enter data mode. [Disconnection request from local side] When NPort Express is in data mode, the user can drive DTR signal to OFF or send the +++ from local serial port to NPort Express. NPort Express will enter the command mode and return the NO CARRIER via serial port, and then input ATH for shot down tcp connection after 1 second.
5 Note: The +++ cannot be divided, the + character can be changed in register S2 and the guard time, which prefixes and suffixes the +++ in order to protect the raw data, can be changed in register S12. [Disconnection request from remote side] After the TCP connection is shot down by the remote Ethernet modem or PC, NPort Express will send the NO CARRIER signal via serial port and return to command mode. AT Commands Reference Info NPort Express supports the following common AT commands used with a typical modem: No. AT command Description Remarks 1 ATA Manually answer 2 ATD <IP>:<Port> Dial up the IP address & Port No. 3 ATE ATE0=Echo OFF ATE1=Echo ON (default) 4 ATH ATH0=On-hook (default) ATH1=Off-hook 5 ATI, ATI0, ATI1, ATI2 Modem version reply OK only 6 ATL Speaker volume option reply OK only 7 ATM Speaker control option reply OK only 8 ATO On line command 9 ATP, ATT Set Pulse/Tone Dialing mode reply OK only 10 ATQ0, ATQ1 Quiet command (default=atq0) 11 ATSr=n Change the contents of S register See S registers 12 ATSr? Read the contents of S register See S registers 13 ATV Result code type ATV0 for digit code, ATV1 for text code 0=OK 1=connect (default) 2=ring 3=No carrier 4=error 14 ATZ Reset (disconnect, enter command mode and restore the flash settings) 3/19
6 15 AT&C Serial port DCD control AT&C0=DCD always on AT&C1=DTE detects connection by DCD on/off (default) 16 AT&D Serial port DTR control AT&D0=recognize DTE always ready (default) AT&D1, AT&D2=reply DTE when DTR On 17 AT&F Restore manufacturer s settings 18 AT&G Select guard time reply OK only 19 AT&R Serial port RTS option command reply OK only 20 AT&S Serial port DSR control reply OK only 21 AT&V View settings 22 AT&W Write current settings to flash for next boot up S Registers No. S Register Description & default value Remarks 1 S0 Ring to auto-answer (default=0) 2 S1 Ring counter (always=0) no action applied 3 S2 Escape code character (default=43 ASCII + ) 4 S3 Return character (default=13 ASCII) 5 S4 Line feed character (default=10 ASCII) 6 S5 Backspace character (default= 8 ASCII) 7 S6 Wait time for dial tone (always=2, unit=sec) no action applied 8 S7 Wait time for carrier (default=3, unit=sec) 9 S8 Pause time for dial delay (always=2, unit=sec) no action applied 10 S9 Carrier detect response time no action applied (always=6, unit 1/10 sec) 11 S10 Delay for hang up after carrier no action applied (always=14, unit 1/10 sec) 12 S11 DTMF duration and spacing (always=100 ms) no action applied 13 S12 Escape code guard time (default=50, unit 1/50 sec) to control the idle time for +++ 4/19
7 Advanced RAW connection (TCP/UDP support) with Data Packing Introduction NPort Express makes an ideal Ethernet gateway for serial RS-232/422/485 data, and support raw data transmission, making it possible for serial data to travel over a LAN. When NPort server receives raw serial data, a TCP/IP or UDP header and trailer are added, and then the resulting packet is sent out over the Ethernet medium. Once the control host receives the TCP or UDP frame, the NOS (Network Operating System) recovers the raw data by decoding the TCP or UDP header and trailer. This allows the user to easily capture the raw serial data via the Ethernet, using either Telnet or a customized TCP or UDP socket program, and provides an ideal solution for long-distance serial data transmission between host and serial device. The Client-Server Principle In general, the Client is a program (e.g., Internet Explorer) which actively requests a specific service, with the service often located on a remote host. A Server on the other hand is a program that passively listens and responds to requests from Clients. It is often the case that Clients reside on an individual s PC and Servers reside on larger and faster computers used specifically to run Server programs (in fact, this type of computer is itself often referred to as a Server). The RAW connection TCP Server/Client The raw connection allows NPort Server to act as a passive server (TCP server) that listens for TCP connection requests from client hosts, or an active client (TCP client) that requests the TCP connection to the specific host for data transmission. The host reads or writes the serial data bi-directionally after the TCP connection has been established. Note: The operating mode RAW connection (TCP server) replaces the older RAW connection mode with the powerful data-packing which helps data transmission more efficient. The RAW connection UDP Server/Client The raw connection UDP server/client supports both server and client ways for data transmission. NPort Express sequentially sends the serial data to the hosts configured in Destination IP addresses, and transfers the data from the hosts configured in Source IP addresses to serial port. NPort Express totally provides 4 IP ranges of both destination hosts and source hosts. 5/19
8 The powerful Data Packing makes data transmission more efficient NPort Express adds the delimiter and force transmit time out for customized data format. Once the user startup with one or two of these settings, NPort Express will automatically send the data from serial port to Ethernet after receiving the delimiter character(s) or receiving serial data time out. This function could meet your specified application requirements like card reader, copy machine, scanner etc. The application Architecture Configuring NPort Express (1) NPort Express (applies to firmware v or above for DE-311/DE-311M) 1-1 Telnet NPort Express IP address (default = ) to access the Telnet console. 1-2 Choose the VT-100 console terminal type by pressing Move the cursor to Server and then press Enter to configure IP address, nestmask, DHCP, and gateway. 1-4 Press ESC, move the cursor to OP_mode, press Enter, and then select RAW connection TCP server, TCP client or UDP server/client mode. 1-5 Press Enter to set the serial port(s) to RAW connection. 1-6 Move the cursor to Pure raw data mode and then press enter for more settings, including TCP port No., etc. 1-7 Press ESC, move the cursor to Save to save the configuration, and then move to Restart to reboot the system. 6/19
9 Notes 1: for TCP server / client Destination IP: Keep blank to allow access for all hosts, or enter an IP address to allow access to only one host. This IP MUST be assigned under TCP client mode. TCP connect on: (for TCP client only) choose the startup for automatic TCP connecting to destination host after system startup and ready; or Any character for building up TCP connection after receiving serial character. Inactivity time: (0~65535 ms) the serial port will be reset if there is no transmission during this time. TCP alive check time: (0-99 min.) the TCP connection will be reset if there is no activity for a length of time equal to tcp_time_out. Data Packing: Delimiter 1 (Hex): keep empty for none trail delimiter needed or input a character in Hex Delimiter 2 (Hex): Keep empty or input the second trail character in Hex Force transmit: (0~65535 ms) system sends the serial data to Ethernet or keep empty for none force transmit needed. Notes 2: for UDP server / client Serial to Ethernet Dest IP addr: 4 ranges of IP address which NPort Express transmits the serial data to with the respective port no. Ethernet to Serial Src IP addr: 4 ranges of source IP address which NPort Express accepts the data from and transmits to the serial port; Keep blank for accepting all hosts. Inactivity time: (0~65535 ms) the serial port will be reset if there is no transmission during this time. TCP alive check time: (0-99 min.) the TCP connection will be reset if there is no activity for a length of time equal to tcp_time_out. Data Packing: Delimiter 1 (Hex): keep empty for none trail delimiter needed or input a character in Hex 7/19
10 Delimiter 2 (Hex): Keep empty or input the second trail character in Hex Force transmit: (0~65535 ms) system sends the serial data to Ethernet or keep empty for none force transmit needed. Introduction of socket interface This interface provides easy-to-use commands for building up customized applications. When using the Socket Interface, connections are established with an IP address and port number. The IP address identifies a remote host and the port number identifies an application process (e.g., 80 for www browser service). The combination of <IP address : port number> allows the user to access the desired application process running on the remote host. NPort Server will launch the bi-directional serial transmission service and then listen for requests from the Client via NPort server s IP and TCP port 4001 (the manufacturer s default value) after the user starts up the raw connection service. (The request is commonly made by application software built in or installed on the user interface PC or terminal refer to the Programming Example given below for more details on how to use this operation mode.) Programming Example 1 The following example was developed under VC for Windows 9x/NT/2000 NPort RAW mode Tx/Rx example program Date: Version: 1.0 Program description: A dumb terminal emulation example program via NPort RAW mode 1. hit <ESC> to stop the program 2. program sends data from the keyboard to NPort 3. program prints to the screen any data read from NPort 4. Syntax: as_raw NPort_IP TCP_PORT 5. Program developed under VC May be used on Windows 9X/NT/2000 OS 8/19
11 #include <winsock2.h> #include <stdlib.h> #include <stdio.h> #include <fcntl.h> #include <string.h> #include <conio.h> #define IP_ERROR 0xFFFEFFFFL Invalid ip address #define INTERVAL msec #define RETRY 50 connect retry count SOCKET Fd; Socket descriptor used on data Tx/Rx unsigned long SOCKET dot2ip(char *dot); sioopen(unsigned long ipaddr,int p); int main(int argc, char *argv[]) { int port,i; unsigned long ip; WSADATA wsadata; char ch,len; char buf[80]; SOCKET fd; if ( argc < 3 ) { printf("syntax: %s NPortIP TCP_Port\n",argv[0]); return -1; ip = dot2ip(argv[1]); if (ip == IP_ERROR) { printf("invalid IP address %s!\n",argv[1]); return -2; port = atoi(argv[2]); On windows we need to call WSAStartup before calling any SOCKET function If your project(vc++,vb,delphi) has include TCP/IP MODULE on it, you do need not to call this function, because it is called automatically when you select TCP/IP module. if (WSAStartup(0x202,&wsaData) == SOCKET_ERROR) { fprintf(stderr,"wsastartup failed with error %d\n",wsagetlasterror()); WSACleanup(); return -5; 9/19
12 connect to remote printf("connecting to --> fd = sioopen(ip,port); if (fd!= INVALID_SOCKET) { printf("ok\n"); printf("<esc> = stop program.\n"); printf("any key = send to remote.\n"); printf("dumb terminal begin...\n"); printf("\n"); sprintf(buf,"welcome to MOXA NPort RAW mode example prog.\r\n"); send(fd,buf,strlen(buf),0); Send welcome string to remote for (;;) { if (kbhit()) { keyboard is hit ch = getch(); if (ch == 27) { user hit <ESC> --> exit printf("\n"); break; send(fd,&ch,1,0); Send data to NPort 10/19 if (ch == '\n') { send(fd,"\r",1,0); send LF as CR-LF if (ch == '\r') { send(fd,"\n",1,0); send CR as CR-LF len=recv(fd, buf, sizeof(buf), 0); if (len <= 0) No data read Sleep(10); Prevent from wasting too much of CPU time else { for (i=0;i<len;i++) printf("%c",buf[i]); closesocket(fd); Close TCP connection else { printf("fail!\n"); On windows we need to call WSACleanup to free SOCKET resource before exiting the program WSACleanup(); printf("hit any key to stop program...\n"); getch(); printf("program exit.\n"); return 0;
13 Convert dot notation to IP address ie: From " " to 0x0102A8C0 unsigned long dot2ip(char *dot) { unsigned long ip; unsigned char *c; int i, d; c = (unsigned char *)&ip; for (i = 4; i-- > 0; ) { d = *dot++ - '0'; if (d < 0 d > 9) return IP_ERROR; while (*dot >= '0' && *dot <= '9') { d = d * 10 + *dot++ - '0'; if (d > 255) return IP_ERROR; *c++ = d; if (*dot++!= '.') break; if (*--dot i) return IP_ERROR; return ip; Connect to remote TCP port SOCKET sioopen(unsigned long ipaddr,int port) { struct sockaddr_in des; int i,j,len; SOCKET fd; BOOL b = TRUE; ULONG mode = 1; /* set to non_delay mode */ unsigned short p; p = htons((unsigned short)port); open socket fd = socket(af_inet, SOCK_STREAM, 0); if ( fd == INVALID_SOCKET ) { return(fd); 11/19
14 Set SOCKET to No Delay mode if (ioctlsocket(fd,fionbio,&mode)) { closesocket(fd); return(invalid_socket); Set remote IP address and port no des.sin_family = AF_INET; des.sin_addr.s_addr = ipaddr; des.sin_port = p; len = sizeof(struct sockaddr_in); connect to remote i = 0; for (;;) { j = connect(fd,(struct sockaddr *)&des, len); if (j == 0) connected break; if (WSAGetLastError() == WSAEISCONN) { already connected j = 0; break; if (i++ >= RETRY) Connected failed too many times --> give up break; Sleep(INTERVAL); Sleep for a while before trying it again. Prevent from wasting too much of CPU time. if( j!= 0 ) { closesocket(fd); return(invalid_socket); return(fd); Can't connect to remote 12/19
15 Programming Example 2 The following program was developed under VB6.0 with serial settings 38400, n, 8, 1 Private Sub cmdconnect_click() If txtip.text = "" Or txtport.text = "" Then Exit Sub Winsock1.Connect txtip.text, txtport.text txtstatus.text = txtstatus.text & "Connecting..." & vbcrlf Timer1.Enabled = True Private Sub cmddisconnect_click() Winsock1.Close txtstatus.text = txtstatus.text & "Connection Close." & vbcrlf Private Sub cmdclose_click() If MsgBox("Are you sure to shutdown the Remote Server application?", vbquestion + vbyesno, "Shutdown") = vbno Then Exit Sub SendData ("Close:") Winsock1.Close Private Sub cmdsendkey_click() Dim strmsg As String strmsg = InputBox("Please enter any letters to send back to the Server.", "Send Key", "") 13/19
16 If strmsg <> "" Then If Not SendData("Keyboard:" & strmsg) Then Winsock1.Close End If End If Private Sub Timer1_Timer() MsgBox "Client could not find server.", vbcritical If Winsock1.State <> sckclosed Then Winsock1.Close End If Timer1.Enabled = False txtstatus.text = txtstatus.text & "Connection Fail." & vbcrlf Private Sub Winsock1_Connect() Timer1.Enabled = False txtstatus.text = txtstatus.text & "Connection Established." & vbcrlf Private Sub Winsock1_DataArrival(ByVal bytestotal As Long) Dim strdata As String Winsock1.GetData strdata txtstatus.text = txtstatus.text &"Get data: "& strdata & vbcrlf & vbcrlf 14/19
17 Private Function SendData(sData As String) As Boolean On Error GoTo ErrorHandler Dim lngtime As Long blnreply = False Winsock1.SendData sdata Do Until (Winsock1.State = 0) Or (lngtime < 10000) DoEvents lngtime = lngtime + 1 If lngtime > Then Exit Do Loop SendData = True Exit Function ErrorHandler: SendData = False MsgBox Err.Description, vbcritical Exit Function End Function Private Sub cmdconnect_click() If txtip.text = "" Or txtport.text = "" Then Exit Sub Winsock1.Connect txtip.text, txtport.text txtstatus.text = txtstatus.text & "Connecting..." & vbcrlf Timer1.Enabled = True 15/19
18 Private Sub cmddisconnect_click() Winsock1.Close txtstatus.text = txtstatus.text & "Connection Close." & vbcrlf Private Sub cmdclose_click() If MsgBox("Are you sure to shutdown the Remote Server application?", vbquestion + vbyesno, "Shutdown") = vbno Then Exit Sub SendData ("Close:") Winsock1.Close Private Sub cmdsendkey_click() Dim strmsg As String strmsg = InputBox("Please enter any letters to send back to the Server.", "Send Key", "") If strmsg <> "" Then If Not SendData("Keyboard:" & strmsg) Then Winsock1.Close End If End If Private Sub Timer1_Timer() MsgBox "Client could not find server.", vbcritical 16/19
19 If Winsock1.State <> sckclosed Then Winsock1.Close End If Timer1.Enabled = False txtstatus.text = txtstatus.text & "Connection Fail." & vbcrlf Private Sub Winsock1_Connect() Timer1.Enabled = False txtstatus.text = txtstatus.text & "Connection Established." & vbcrlf Private Sub Winsock1_DataArrival(ByVal bytestotal As Long) Dim strdata As String Winsock1.GetData strdata txtstatus.text = txtstatus.text &"Get data: "& strdata & vbcrlf & vbcrlf Private Function SendData(sData As String) As Boolean On Error GoTo ErrorHandler Dim lngtime As Long blnreply = False Winsock1.SendData sdata Do Until (Winsock1.State = 0) Or (lngtime < 10000) DoEvents lngtime = lngtime /19
20 If lngtime > Then Exit Do Loop SendData = True Exit Function ErrorHandler: SendData = False MsgBox Err.Description, vbcritical Exit Function End Function Programming Example 3 The following UDP program was developed under VB6.0 with NPort Express port 4001 Objects: Text1 --- for data sent to NPort Express Text2 --- for data received from NPort Express Command1 --- End Command2 --- Send the contents of Text1 / Private Sub Command1_Click() If Winsock1.State <> sckclosed Then Winsock1.Close End If 18/19
21 End Private Sub Command2_Click() Winsock1.SendData Text1.Text Private Sub Form_Load() With Winsock1.Protocol = sckudpprotocol.remotehost = " ".RemotePort = 4001.LocalPort = 4001.Bind End With Form1.Caption = "UDP transmission via port 4001" Private Sub Winsock1_DataArrival(ByVal bytestotal As Long) Dim strdata As String Winsock1.GetData strdata Text2.Text = Text2.Text + strdata Reference Information You may access Moxa s website at for firmware downloads and upgrades. 19/19
NPort s Ethernet Modem Mode
Tom Lu, Senior Engineer, Moxa Technical Support Dept. [email protected] This Tech Note applies to the following NPort models: NPort DE-211 NPort DE-311 NPort DE-311M NPort 5100 series NPort IA5150 NPort
Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.
Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION
Communicate with Test Instruments Over LAN Using Visual Basic
Communicate with Test Instruments Over LAN Using Visual Basic Application Note 1555 When you order a new test and measurement instrument, you may discover that it has a local area network (LAN) interface
NPort. Copyright 2008 Moxa Inc. Released on July 15, 2008
Moxa Technical Support Team [email protected] This Tech Note applies to the NPort device servers. The following models are included: NPort DE-211 NPort DE-311 NPort DE-311M NPort 5100 series NPort 5200
LS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
NPort 5110 Series User s Manual
First Edition, December 2004 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: [email protected] The Americas
IP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
Configuration Guide for Ascom Communications Server, Remote Management Package
Configuration Guide for Ascom Communications Server, Remote Management Package Introduction This document outlines the necessary steps and guidelines to configure the Ascom Communications Server, Remote
Application Note. Terminal Server G6
MICROSENS GmbH & Co. KG Küferstr. 16 59067 Hamm/Germany Tel. +49 2381 9452-0 FAX +49 2381 9452-100 E-Mail [email protected] Web www.microsens.de Summary As of firmware version v10.6 MICROSENS Generation
Quectel Cellular Engine
Cellular Engine GSM UART Port Application Notes GSM_UART_AN_V1.01 Document Title GSM UART Port Application Notes Version 1.01 Date 2009-11-16 Status Document Control ID Release GSM_UART_AN_V1.01 General
VoIP H.323 Series. VoIP Gatways: VoIP 422/404/440/800 VoIP Routers: VoIP 404R/440R/200R/110R. Quick Setup Guide
VoIP H.323 Series VoIP Gatways: VoIP 422/404/440/800 VoIP Routers: VoIP 404R/440R/200R/110R Quick Setup Guide Important Information In this guide, you will learn how to setup our VoIP gateway and Routers
Installation & Configuration Manuel. Socket Server. OpenAT application
Installation & Configuration Manuel Socket Server OpenAT application 2009 / 05 / 29 2 ! CAUTION! ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
MODBUS TCP to RTU/ASCII Gateway
MODBUS TCP to RTU/ASCII Gateway Users Manual Model MODport-101, MODport-102, MODport-104 July 2011 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
TRP-C31M MODBUS TCP to RTU/ASCII Gateway
TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci
Firmware Loader User Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876
HOW TO USE YOUR INTELE-MODEM
HOW TO USE YOUR INTELE-MODEM 305-008800 Ultratec, Inc. 450 Science Drive Madison, WI 53711 (608) 238-5400 (Voice/TTY) Fax: (608) 238-3008 Email: [email protected] www.ultratec.com First Edition October
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR
AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS
NPort 5100 Series User s Manual
User s Manual Seventh Edition, April 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be
NB6 Series Quality of Service (QoS) Setup (NB6Plus4, NB6Plus4W Rev1)
NB6 Series Quality of Service (QoS) Setup (NB6Plus4, NB6Plus4W Rev1) NB6 Series and Quality of Service (QoS) The following Quality of Service (QoS) settings offer a basic setup example, setting up 3 devices
BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE
BLUETOOTH SERIAL PORT PROFILE iwrap APPLICATION NOTE Thursday, 19 April 2012 Version 1.2 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes no responsibility for
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
NPort 5100 Series User s Manual
First Edition, June 2006 www.moxa.com/product MOXA Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: [email protected] The software described
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
7.7 Ethernet Communication (AFPX-COM5)
7.7 Ethernet Communication (AFPX-COM5) 7.7.1 AFPX-COM5 Overview The communication cassette AFPX-COM5 has an Ethernet interface at the COM1 port and a 3-wire RS232C interface at the COM2 port. The Ethernet
GSM. Quectel Cellular Engine. GSM TCPIP Application Notes GSM_TCPIP_AN_V1.1
GSM Cellular Engine GSM TCPIP Application Notes GSM_TCPIP_AN_V1.1 Document Title GSM TCPIP Application Notes Version 1.1 Date 2011-09-22 Status Document Control ID Release GSM_TCPIP_AN_V1.1 General Notes
EXTENDED FILE SYSTEM FOR F-SERIES PLC
EXTENDED FILE SYSTEM FOR F-SERIES PLC Before you begin, please download a sample I-TRiLOGI program that will be referred to throughout this manual from our website: http://www.tri-plc.com/trilogi/extendedfilesystem.zip
xpico User Guide Part Number 900-618 Revision A April 2012
xpico User Guide Part Number 900-618 Revision A April 2012 Copyright and Trademark 2012 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Packet Sniffing and Spoofing Lab
SEED Labs Packet Sniffing and Spoofing Lab 1 Packet Sniffing and Spoofing Lab Copyright c 2014 Wenliang Du, Syracuse University. The development of this document is/was funded by the following grants from
RTU-COM with GSM. User Notes and Short Form AT Commond Survey
1 RTU-COM with GSM User Notes and Short Form AT Commond Survey V. 1.00 / Feb 2006 / Doc 40143 2 1. Introduction This document is a guide for using GSM communication and GSM data accounts, and changing
USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16
RS232 Serial TO Ethernet convert Module USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16 Jinan USR Technology Co., Ltd. works on LAN and WAN and wireless for MCU to Ethernet Solutions, Ethernet,
UDS10 UDS100 User Guide
UDS10 UDS100 User Guide Part Number 900-360 Revision A June 2004 Copyright & Trademark 2004, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
Date Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
SWITCHED TELEPHONE NETWORK LEASED LINE
Distribué par : Contact : [email protected] Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MTi 133-1 V34 33 600 b/s INDUSTRIAL MODEM SWITCHED
Socket Programming. Request. Reply. Figure 1. Client-Server paradigm
Socket Programming 1. Introduction In the classic client-server model, the client sends out requests to the server, and the server does some processing with the request(s) received, and returns a reply
TCPIP Application Note for WCDMA Solution V2.0
TCPIP Application Note for WCDMA Solution V2.0 Scope SIM5218, SIM5215, SIM5216, SIM5320 Reference SIMCOM_SIM5320_Serial_ATC_EN_V1.26.doc -1-2012-11-20 Content 1. External PPP Setting...3 2. SIMCom Internal
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
OfficeServ Link. User Guide. Version 2.1 June 2005
OfficeServ Link User Guide Version 2.1 June 2005 OfficeServ Link Version 2.1 User Guide This manual should be read before the installation and operation of the OfficeServ Link Software. COPYRIGHT This
Configuring IP to Serial with Auto Answer and Serial to IP
Configuring IP to Serial with Auto Answer and Serial to IP You can configure the AirLink device to: Auto answer incoming TCP/IP or UDP/IP connections and send the packet payload out the AirLink device
The Shift to Wireless Data Communication
The Shift to Wireless Data Communication Choosing a Cellular Solution for Connecting Devices to a WWAN Dana Lee, Senior Product Manager [email protected] Recent developments in the wireless and industrial
DSX Master Communications
DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which
Leased Line Support for Cisco 2600/3600 Series Analog Modems
Leased Line Support for Cisco 2600/3600 Series Analog Modems This feature adds one modem AT command (AT&L) and two AT registers to be added to the modemcap for the appropriate leased lines. Several new
How-To Guide. SigCard1 (With Microsoft Access) Demo. Copyright Topaz Systems Inc. All rights reserved.
How-To Guide SigCard1 (With Microsoft Access) Demo Copyright Topaz Systems Inc. All rights reserved. For Topaz Systems, Inc. trademarks and patents, visit www.topazsystems.com/legal. Table of Contents
1 Getting Started. Before you can connect to a network
1 Getting Started This chapter contains the information you need to install either the Apple Remote Access Client or Apple Remote Access Personal Server version of Apple Remote Access 3.0. Use Apple Remote
NPort DE-311 Hardware Installation Guide
NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation
UDS1100 User Guide Part Number 900-417 Revision B June 2006
UDS1100 User Guide Part Number 900-417 Revision B June 2006 Copyright & Trademark Contacts 2006, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in
5610-16/5610-8 User s Manual
5610-16/5610-8 User s Manual First Edition, August 2003 Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 www.moxa.com [email protected] 5610-16/5610-8 User s Manual The software
Configuring CSS Remote Access Methods
CHAPTER 11 Configuring CSS Remote Access Methods This chapter describes how to configure the Secure Shell Daemon (SSH), Remote Authentication Dial-In User Service (RADIUS), and the Terminal Access Controller
Introduction to Analyzer and the ARP protocol
Laboratory 6 Introduction to Analyzer and the ARP protocol Objetives Network monitoring tools are of interest when studying the behavior of network protocols, in particular TCP/IP, and for determining
NPort 5200 Series User s Manual
User s Manual Eighth Edition, January 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
GW400 VoIP Gateway. User s Guide
GW400 VoIP Gateway User s Guide P/N: 956YD30001 Copyright 2006. All Rights Reserved. Document Version: 1.0 All trademarks and trade names are the properties of their respective owners. i Table of Contents
Kiwi SyslogGen. A Freeware Syslog message generator for Windows. by SolarWinds, Inc.
Kiwi SyslogGen A Freeware Syslog message generator for Windows by SolarWinds, Inc. Kiwi SyslogGen is a free Windows Syslog message generator which sends Unix type Syslog messages to any PC or Unix Syslog
Router Lab Reference Guide
Router Lab Reference Guide 1 PURPOSE AND GOALS The routing lab allows testing different IP-related protocols and solutions in a close to live environment. You can learn how to configure Cisco routers and
XPort Device Server User Guide
XPort Device Server User Guide Part Number 900-270 Revision P November 2014 Intellectual Property 2014 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
DSA-1000 / PRT-1000 Device Server / Thermal Printer
LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,
Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:
the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the
MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
WEB CONFIGURATION. Configuring and monitoring your VIP-101T from web browser. PLANET VIP-101T Web Configuration Guide
WEB CONFIGURATION Configuring and monitoring your VIP-101T from web browser The VIP-101T integrates a web-based graphical user interface that can cover most configurations and machine status monitoring.
IP Serial Server. User Manual
IP Serial Server IPS-101 (1-port) IPS-102 (2-port) IPS-201 (1-port) IPS-202 (2-port) IPS-204 (4-port) User Manual V2.0 2009.03.09 Page: 1 / 62 Copyright This document contains proprietary information that
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
Lecture 2-ter. 2. A communication example Managing a HTTP v1.0 connection. G.Bianchi, G.Neglia, V.Mancuso
Lecture 2-ter. 2 A communication example Managing a HTTP v1.0 connection Managing a HTTP request User digits URL and press return (or clicks ). What happens (HTTP 1.0): 1. Browser opens a TCP transport
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
EMG Ethernet Modbus Gateway User Manual
EMG Ethernet Modbus Gateway User Manual Rev 2.2 07/2010 CONTENTS 1. Introduction 1.1. General Features 1.2 Installing the Drivers 2. Configuration 2.1 Main Device Parameters 2.1.1 RS485 Serial Communication
Copyright and Trademarks. How to Use this Guide. Phone Adapter with Router
Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered trademark or trademark of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.
VOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide
VOIP-211RS/210RS/220RS/440S SIP VoIP Router User s Guide Trademarks Contents are subject to revise without prior notice. All trademarks belong to their respective owners. FCC Warning This equipment has
Note: these functions are available if service provider supports them.
Key Feature New Feature Remote Maintenance: phone can be diagnosed and configured by remote. Zero Config: automated provisioning and software upgrading even through firewall/nat. Centralized Management:
Vector F336E/2LL MODEM USER'S MANUAL
Vector F336E/2LL MODEM USER'S MANUAL CONTENTS CHAPTER 1 INTRODUCTION Features----------------------------------------------------------------1 Package Contents-----------------------------------------------------1
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
Atop ABLELink Ethernet-Serial Server GW51C- MAXI
Atop ABLELink Ethernet-Serial Server GW51C- MAXI User Manual Version 1.1 Updated on 2004/08/18 Tel: 886-3-5508137 Fax: 886-3-5508131 www.atop.com.tw IMPORTANT ANNOUNCEMENT The information contained in
Voice Gateway with Router
Voice User Guide Model No. SPA3102 Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered trademark or trademark of Cisco Systems, Inc. and/or its affiliates
isco Connecting Routers Back to Back Through the AUX P
isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
RS232/485 TCP/IP converter TPC2RS. Ver. 01A- GB
RS232/485 TCP/IP converter TPC2RS Ver. 01A- GB ----------- TCP2RS -------------- User s manual -------------------- page 2/43 1: INTRODUCTION...5 1.1 NETWORK PROTOCOLS...5 1.1.1 Packing Algorithms...6
µtasker Document FTP Client
Embedding it better... µtasker Document FTP Client utaskerftp_client.doc/1.01 Copyright 2012 M.J.Butcher Consulting Table of Contents 1. Introduction...3 2. FTP Log-In...4 3. FTP Operation Modes...4 4.
Operating Instructions
Operating Instructions (For Setting Up) Digital Imaging Systems Installation Overview Model No. DP-8060 / 8045 / 8035 Table of Contents Setting Your Machine Installation Overview General Installation Overview...
Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice
Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
V101 SIP VoIP Telephone Adaptor User Manual V1.1m
V101 SIP VoIP Telephone Adaptor User Manual V1.1m Quick Guide Step 1: Broadband (ADSL/Cable Modem) Connections for V101 A. Connect V101 LAN port to ADSL NAT Router as the following connection. B. Connect
A More Secure and Cost-Effective Replacement for Modems
A More Secure and Cost-Effective Replacement for Modems Lantronix, Inc. 15353 Barranca Parkway Irvine, CA 92618 Tel: +1 (800) 422-7055 Fax: +1 (949) 450-7232 www.lantronix.com Abstract For companies, service
Chapter 46 Terminal Server
Chapter 46 Terminal Server Introduction... 46-2 TTY Devices... 46-2 Multiple Sessions... 46-4 Accessing Telnet Hosts... 46-5 Command Reference... 46-7 connect... 46-7 disable telnet server... 46-7 disconnect...
Liebert IntelliSlot Web Cards
Monitoring For Business-Critical Continuity Liebert IntelliSlot Web Cards Firmware Upgrade Manual Liebert IntelliSlot Web Card, Liebert IntelliSlot Web Card-LB, Liebert IntelliSlot Web Card-LBDS, Liebert
SMC7004ABR Barricade Broadband Router Installation Instructions
SMC7004ABR Barricade Broadband Router Installation Instructions SPECIAL NOTE: Part D Upgrading the Firmware in Your Barricade MUST occur in ALL installations for multiple VPN sessions to work!!! SPECIAL
PortShare Software Quick Start Guide. PortShare
PortShare PortShare Software Quick Start Guide Use with LES1101A, LES1102A, LES1108A, LES1116A, LES1132A, LES1148A, LES1208A, BLACK LES1216A, BOX LES1232A, LES1248A, LES1202A, LES1203A-11G, LES1204A-3G,
1. MOXA NPort Express TCP/IP to RS-232 server
GS_GSR_GCR_UserManual_App_E_MOXA_V01.doc / 17.08.2009 GeoSIG Ltd. Appendix E Page E-1 1. MOXA NPort Express TCP/IP to RS-232 server 1.1. General Explanations The NPort Express RS-232/422/485 Device server
1 Port RS232 Serial over IP Ethernet Device Server
1 Port RS232 Serial over IP Ethernet Device Server NETRS2321P *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
Accessing Diagnostics using a Dialup Modem
Purpose This application note is meant to guide a user through the setup and use of a dial-up modem to retrieve diagnostics data from a remote master. Equipment Used This application note was written specifically
System Requirements. Hiro H50113
1 Hiro H50113 System Requirements Hiro H50113 Computer with Pentium 200 MMX or higher processor. Windows 2000, Windows XP Home / Professional, XP Professional x64 Edition, Vista 32 / 64 Families, Windows
