"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

Size: px
Start display at page:

Download ""A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type"

Transcription

1 Single Pump, "OBE" Type Electro-Hydraulic Proportional & Flow Type Input Signal for Safety valve Input Signal for Flow Amplifier Proportional Solenoid Sensor Valve Piston (S Input Voltage L) Performance Characteristics (S Input Voltage L). Unloading pressure when input signal is V.. Safety valve setting pressure Tilt Angle Sensor Bias Piston A6/A/A7/A6 Graphic Symbols A7/A9/A4 Example of Specified Symbol (E.) M 6M M at Input Signal is V kgf/cm MPa PSI Model Number Designation A6 -F R 4EH 7 R S -6-4 Series Number Mounting Direction of Rotation Type at Input Signal is V Amplifier Direction Port Position Compensation Number Design Number * Design Std. A6 (.8 cm A (. cm A7 (6.9 cm A6 (6. cm A7 (7. cm A9 (9. cm A4 (4. cm F: Flange Mtg. L: Foot Mtg. Viewed from Shaft End R: Clockwise (Normal) 4EH: "OBE" Type Proportional & Flow Type Specify between 6.9 MPa and Maximum Operating (Refer to above Table) Viewd from Shaft End R: Right L: Left None: Axial Port S: Side Port S: Side Port. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. Amplifier Compensation Number may differ according to the main machine conditions. Consult Yuken for detail.. Design Standards: None...Japanese Standard "JIS" 9...N.American Design Standard Refer to 86

2 A"A" Series PISTON PUMPS Specifications Descriptions Geometric Displacement Model Numbers A6 A A7 A6 A7 A9 A4 cm /rev (cu. in..8 (.964). (.) 6.9 (.) 6. (.4) 7. (4.7) 9. (.) 4. (8.8) Operating MPa (PSI) Rated Intermittent 6 () () 6 () 6 () 6 () () 6 () () (6) 8 (46) (6) 8 (46) (6) 8 (46) Shaft Speed Range r/min 6-8 Max. Flow L/min (U.S. GPM) 8.4 (7.) 4. (.6) 66.4 (7.). (6.7) 6. (.) 6. (4.) 6. (69.) Flow Coil Resistance Input Impedance Supply Electric Power Power Input (Max.) Flow Output Signal Alarm Signal Output (Open Collector) Ambient Temperature C ( F) Mass Min. Pres. Required for Flow Adj. Hysteresis Repeatability Input Signal Min. Adjustment Hysteresis Repeatability Input Signal kg (lbs.) MPa (PSI) MPa (PSI) Ω [@ C (68 F)] Flange Mtg. Foot Mtg. W.7 (4.6).9 (.).7 (4.6).9 (.). (9) % or less % or less Max. Flow / V DC.7 () % or less % or less Specified / V DC Flow : kω. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page for the details.. Maximum flow differs to shaft speed. The value listed above indicates shaft speed of 8 r/min. For other shaft speed calculate by the ratio of shaft speed. Pres. : kω 4 V DC ( - 8 V Included Ripple) V DC / Max. Flow V DC / Specified Voltage : Max. V DC Current : Max. 4 ma - ( - ) (With Circulated Air). (7) 6. (8.) 9. (86.4) 4. (9.9) 64 (4) 76 (68) 76. (69) 97 (4) 98 (6) (7) Pipe Flange Kits For Pipe flange, refer to form of pressure compensator type on page 4. Instructions Input Signal The pump is on unload condition when the pump is operated without input signal voltage. Electric Source Always turn off electric source whenever the connector for swash plate tilt angle sensor is removed. Compensation of Pump Maximum Regulated Flow at Frequency If the same maximum flow is required at Hz or 6 Hz, connect short plug in the amplifier to 6 Hz at the place where supplied frequency is 6 Hz. At this condition, maximum flow comes to the same value at Hz. If short plug is used at 6 Hz without making the change, maximum flow increased in proportion to frequency. Painting on Amp. Box and Solenoiod To maintain suitable radiation effect, the amp. box and the solenoid of the control valve should not be painted. 87

3 vs. Input Signal A6 U.S.GPM 8 A A7 6 4 L / min Note: Pump characteristics at 8 r/min is the same as those at r/min where frequency is compensated. (Refer to page 87.) Full Cut-off Pres. vs. Input Signal A6 U.S.GPM L / min 8 4 A7 U.S.GPM L / min U.S.GPM L / min r/min r/min U.S.GPM L / min r/min r/min 8 r/min r/min 4 A9 U.S.GPM L / min A4 U.S.GPM L / min r/min 4 6 r/min r/min r/min 8 r/min r/min 8 r/min r/min Full Cut-off PSI 4 MPa 8 A* - * R4EH7.M A* - * R4EH4.M 4 A* A* - * R4EH.6M - * R4EH.7M A* - * R4EH6.9M Full Cut-off kgf/cm (PSI) 8 (4) () 4 () 7 () 4 A* - * R4EH8 A* - * R4EH A* - * R4EH4 A* - * R4EH7 Refer to page 7 to 4 for performance characteristics of pressure compensator type excluding characteristics appeared on this catalogue. 88

4 A"A" Series PISTON PUMPS Flange Mtg.: A6-FR4EH* - * -4/49 A-FR4EH* - * -4/49 Axial Port Type See. (.9) 44 (.67) Air Vent (.) Hex. Soc. G / Thd. 9 (9.4) (8.7) 9 (.) (.98) [(.87) Hex. Head Plug Furnished] 44. (.7) 6. (.6) (.98) "C" Thd. 9(.7) Dia.. (9.9) 7. (6.8) 47.6 (.874) 8. (.4).4(.86).8(.8) 96 (.78) 9(.7) Dia. 44 (.67). (.874) 6 (.6) 94 (.7) "D" Thd. 7(.67) Deep 8 Places (.47) 7 (6.77) 9.(.7) 9.(.7488) Dia. 8.(.) 8.(.48) Dia. 4.79(.886) 4.76(.874). Install the pump so that the "" is at the top.. Do not touch the screw because it is adjusted at the time of shipment.. For detail of amplifier, refer to page 9. Model Numbers "C" Thd. "D" Thd. Rc /8 M SAE #8 /8-6 UNC A6/A-FR4EH* - * -4 A6/A-FR4EH* - * -49 (.4) 9(.74) Dia. 6 (4.7) (.) View Arrow R (R.47) 8 (.7) Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 4 for port mounting dimensions. Refer to page 4 for the dimensions of mounting bracket. 89

5 Flange Mtg.: A7-FR4EH* - * -4/49 Axial Port Type [(.87) Hex. Head Plug Furnished] See. (6.) 46 (.7) Air Vent (.) Hex. Soc. G / Thd. 6. (.) 4. (9.9) 77 (.) (.8) 9 (.) 9. (.7) "C" Thd. (.6) (.6) Dia. 8.7 (.) 67. (.) 77. (6.99) 4. (.6) (4.) (.6) Dia. 48. (.8). (.89) 7 (.8) (.98) "D" Thd. "E" Deep 8 Places (.47) 9 (7.68).(.87).(.874) Dia..(.98) 4.8(.978).6(4.).(.998) Dia. 6.8(.) 6.(.). Install the pump so that the "" is at the top.. Do not touch the screw because it is adjusted at the time of shipment.. For detail of amplifier, refer to page 9. Model Numbers "C" Thd. "D" Thd. A7-FR4EH* - * -4 A7-FR4EH* - * -49 Rc / SAE # "E" mm (IN.) M 9 (.7) 7/6-4 UNC (.79) 4 (.) (4.7) Dia. 46 (.7) 74 (6.8) View Arrow R4 (R.) (.98) Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 46 for port mounting dimensions. Refer to page 46 for the dimensions of mounting bracket. 9

6 A"A" Series PISTON PUMPS Axial Port Type Flange Mtg.: A6-FR4EH* - * -4/49 [(.87) Hex. Head Plug Furnished]. (6.) 46 (.7) Air Vent (.) Hex. Soc. G / Thd. 74 (.79) 6 (.8). (.99) 4. (.7) 6 (.44) 9. (.7) "C" Thd. (Both Sides) See (.6) Dia.. (.8). (7.97) 8.7 (.) 67. (6.9) 4 (.7) 9 (.4) (.8) Dia. 6 (6.4). (.89) 76 (.99) 6 (4.7) "D" Thd. "E" Deep 8 Places 7 (8.) (.47).7(.).7(.48) Dia..(.9).4(.8).6(4.).(.998) Dia. 4 (.6) 49 (.9). Install the pump so that the "" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged.. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page (.8) 7.94(.6) 4 (.) (.98) Model Numbers "C" Thd. "D" Thd. A6-FR4EH* - * -4 A6-FR4EH* - * -49 Rc /4 SAE # M 7/6-4 UNC "E" mm (IN.) 9 (.7) (.79) (4.7) Dia. 46 (.7) 74 (6.8) R4 (R.) View Arrow Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 47 for port mounting dimensions. Refer to page 47 for the dimensions of mounting bracket. 9

7 Flange Mtg. Amplifier Direction "L" : A7-FR4EH* L_S- * -6/69 4 (.6) "C" Thd. (Both Sides) 6 (.6) 6 (.44) 9. (.77) 9. (.7) Air Vent (.) Hex. Soc. G / Thd. 7. (4.) 9 (.74) 89. (.) 7 (.87) (6.) 9 (.74) 7 (.87) Plug (.79) Hex. Soc..4 (.6) 4 (.7) 9 (.4) 79. (7.7) 4 (.) 7.97(.8) 7.94(.6) 4.4 (4.4) 8 (7.9). (8.4) 6(.) Dia. "E" Thd. 7(.67) Deep 6. 6 (.) (.6) 8 (.7) 46. (9.7) 6. (.7).7(.).7(.48) Dia..(.9).4(.8) 7.(.) 6.9(4.998) Dia. 8 (.7) (.8) Dia. Spotface (From Rear) Places 4.4 (4.4) 4 (.8) 8 (7.6) (8.) 8 (4.6) 7(.6) Dia. Spotface (From Rear) Amplifier Direction "R" : A7-FR4EH* R_S- * -6/69 Eye Bolt (M) [(.87) Hex. Head Plug Furnished] 7. (4.6) 69.9 (.7) 8(.) Dia. Case (.) Hex. Soc..7 (.46) 46. (9.7) "D" Thd. "F" Deep View Arrow. Install the pump so that the "" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged.. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 9.. If you use the special sequence valve, remove the plug. Model Numbers "C" Thd. "D" Thd. "E" Thd. A7-FR4EH** S- * -6 A7-FR4EH** S- * -69 Rc /4 SAE # M /- UNC M /8-6 UNC Dimensions mm (IN.) F 9 (.7) (.8) Refer to page 48 for the dimensions of mounting bracket. 9

8 A"A" Series PISTON PUMPS Flange Mtg. Amplifier Direction "L" : A9-FR4EH* L_S- * -6/69 "C" Thd. (Both Sides).7 (4.87) 9. (4.7) (.) 9 (.74) (.9) 6 (.48) G / Thd. 7 (4.) (6.) 89. (.) Air Vent (.) Hex. Soc (.68) (.68) Plug (.79) Hex. Soc. 8.7 (.) (4.4) 9.6(.764) 9.(.7) 89 (7.44) (8.78) 6.6 (6.6) (.6) Dia. "E" Thd. "F" Deep. (.89) (.87) (.9) 7 (.6) 4 (.76) 8.(.) 8.(.498) Dia. 4.6(.668) 4.8(.66).4(6.).(.998) Dia..(.8) Dia. Through 9(.4) Dia. Spotface (From Rear) R 6.6 (R.87) (6.6) (4.) (4.) 7 (.) Amplifier Direction "R" : A9-FR4EH* R_S- * -6/69 [7(.6) Hex. Head Plug Furnished] Eye Bolt (M) 77.8 (.6) 48(.89) Dia. 4.9 (.689) 7 (.6) "D" Thd. "F" Deep View Arrow. Install the pump so that the "" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged.. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 9.. If you use the special sequence valve, remove the plug. Model Numbers "C" Thd. "D" Thd. "E" Thd. A9-FR4EH** S- * -6 A9-FR4EH** S- * -69 Rc /4 SAE # M /- UNC M 7/6-4 UNC Dimensions mm (IN.) F 9 (.7) (.8) Refer to page 49 for the dimensions of mounting bracket. 9

9 Flange Mtg. Amplifier Direction "L" : A4-FR4EH* L_S- * -6/69 "C" Thd. (Both Sides) 49. (.89) 89 (.) (.) (4.4) (.9) 7 (.76) G / Thd (4.) (7.) 89. (.) 7 7 Air Vent (.) Hex. Soc. (.8) (.8) Plug (.79) Hex. Soc. 8.7 (.) (4.).4(.486).(.474) 8.6 (9.) 9 (7.) (8.86) (.6) Dia. "E" Thd. "H" Deep. 4 (.89) (.94) 6 (.) 99. (.79) 7. (4.7) 44.4(.7) 44.4(.748) Dia. 49.9(.944) 49.(.97).4(6.).(.998) Dia. R (R.87) (4.4) 8.6 (9.) 7 (.7) (4.4) 4 (.).(.8) Dia. Through 9(.4) Dia. Spotface (From Rear) Amplifier Direction "R" : A4-FR4EH* R_S- * -6/69 [7(.6) Hex. Head Plug Furnished] Eye Bolt (M) 77.8 (.6) 48(.89) Dia. Case (.) Hex. Soc. 4.9 (.689) 99. (.79) "D" Thd. "F" Deep View Arrow. Install the pump so that the "" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged.. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 9.. If you use the special sequence valve, remove the plug. Model Numbers "C" Thd. "D" Thd. "E" Thd. A4-FR4EH** S- * -6 A4-FR4EH** S- * -69 Rc /4 SAE # M /- UNC M 7/6-4 UNC Dimensions mm (IN.) F H 9 (.7) 9 (.7) (.8) (.79) Refer to page for the dimensions of mounting bracket. 94

10 A"A" Series PISTON PUMPS Detail of Amplifier Connecting Terminal LED for Power Supply /6 Hz Short Plug P GAIN CMG FMG LQC DITHER FUSE 6Hz Hz Compensation Cartridge 4 V V ALM C ALM S SMQ SMP Q IN C P IN C H SPARE FUSE Connector for Tilt Angle Sensor Terminal P IN C Q IN SMP SMQ V 4 V ALM S ALM C CH Name Input Signal, (+) Input Signal (COM) Input Signal, Flow (+) Sensor Monitor Output, Sensor Monitor Output, Tilt Angle Power Supply Alarm Output Alarm Output (COM) Output Current Check (to COM) Note. For "SENSOR MONITOR" terminal, external instruments should have input impedance of more than kω.. For "CH" terminal, external instruments should have input impedance of more than kω.. Volume adjustment of "DITHER", "GAIN", "CMG", "FMG" and "LQC" is made at the time of shipment. Adjustment at the customer is not required. 4. Use shielded cable for "Input" connection. The ground of the shielded cable must be connected to input signal side. Circuit Schematic ALARM SIG COM P SENSOR MONITOR PRESS. SENSOR P IN A C P GAIN ALARM LQC Q IN D A CMG OSC CH DITHER POSITION SENSOR FMG 4 V V Q SENSOR MONITOR 9

Vickers. Piston Pumps

Vickers. Piston Pumps Vickers Piston Pumps xial Piston Pumps Fixed and Variable Displacement PF, PF, PF PV /6, PV /, PV /9, PV and PV 9 to SE PV /6, PV /, PV /9 to DIN/ISO 39, Part G-379 Contents asic characteristicts..........................................................................................3

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

Table of Contents. M Series Variable Displacement Piston Pumps

Table of Contents. M Series Variable Displacement Piston Pumps Table of Contents M Series Variable Displacement Piston Pumps Introduction.... 3 Hydraulic System Design Calculations.... 4 Model Code Selection.... 5 Model Code Options.... 6 Specifications and Performance...

More information

Flow Control (and Check) Valves FG FCG -01/02/03/06/10. Specifications / Model Number Designation / Others. Min. Metred Flow Capacity

Flow Control (and Check) Valves FG FCG -01/02/03/06/10. Specifications / Model Number Designation / Others. Min. Metred Flow Capacity low Control (and Check) Valves -//3/6/ Mounting Specifications / Model Number esignation / Others Specifications Max. Metred low Capacity () Min. Metred low Capacity () Max. Operating Pressure () Approx.

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

Vickers PVM Piston Pumps

Vickers PVM Piston Pumps Vickers PVM Piston Pumps 18-141cc 3 (1.1-8.6in 3 ) M-Series Industrial Variable Displacement M-Series Mobile Variable Displacement Table of Contents M Series Variable Displacement Piston Pumps Principles

More information

PVM Piston Pumps Service Manual

PVM Piston Pumps Service Manual PVM Piston Pumps Service Manual PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Table of Contents Service Parts Pump Description... 3 Basic pump Pump Operation Controls Types Part Identification...

More information

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Technical Catalog PVQ10 PVQ13 PVQ20 PVQ25 PVQ32 PVQ40 PVQ45 Table of Contents Introduction......................................................................................................

More information

Pressure Relief. Pressure Relief Valves. Vickers

Pressure Relief. Pressure Relief Valves. Vickers Vickers Pressure Relief Pressure Relief Valves Remote Controls, Relief and Sequence Valves, and Single and Multiple Pressure Solenoid and Air Operated Relief Valves 511./EN/1297/A Introduction Remote Controls

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY28-2662-CD/US

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY28-2662-CD/US P2/P3 Series Piston Pumps Variable Displacement zp9 Catalog HY28-2662-CD/US A3 Series P2/P3 A4 General Information General Information Series P2/P3 P2 Series The newly developed variable displacement piston

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Dual Path Mobile Pump

Dual Path Mobile Pump Dual Path Mobile Pump Technical Manual 350 Series 350 Series Mobile Pump Introduction Single Assembly* Dual Path Assembly The 350 Series mobile pump is an advanced, closed circuit, servo controlled, axial

More information

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics

More information

DCS Input/Output Relay Card Series

DCS Input/Output Relay Card Series Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US Series PAVC Variable Displacement Piston Pumps zp1 Catalog HY28-2662-CD/US 1 Introduction Series PAVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *Approx. Noise

More information

005 SERIES MODULAR VALVES. Pub. EC-1401. General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type

005 SERIES MODULAR VALVES. Pub. EC-1401. General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type 5 SERIES General Information Up to 5 Ma (3 SI), 1 L /m in (6 USGM) ub EC-11 MODULR VLVES hese modular valves have the same mounting surface as those for the DSG-5 solenoid operated directional valves and

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Joystick PVRES and PVREL. Technical Information

Joystick PVRES and PVREL. Technical Information Joystick PVRES and PVREL Technical Information Contents Revision History PVRES General PVRES Accessories PVREL General Table of Revisions Date Page Changed Rev Mar 2003 All First edition AA May 2010 16

More information

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) 83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Pumps and Motors Conversion factors 1 kg... 2,20 lb 1 N... 0,225 lbf 1 Nm... 0,738 lbf ft 1 bar...14,5 psi

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits. Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)

More information

Fixed displacement vane pumps

Fixed displacement vane pumps Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING 1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: regulateurs@regulateurs-europa.com 1115 4G

More information

Axial Piston Variable Motor A6VM

Axial Piston Variable Motor A6VM Electric Drives and Controls Hydraulics Linear otion and ssembly Technologies Pneumatics Service xial Piston Variable otor 6V RE 91 604/05.06 1/76 Replaces: 06.03 Technical data sheet Series 6 Sizes Nominal

More information

PVH131/141 Variable Displacement Piston Pump - 11 Design

PVH131/141 Variable Displacement Piston Pump - 11 Design Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001 Chapter 11 SERVO VALVES Fluid Power Circuits and Controls, John S.Cundiff, 2001 Servo valves were developed to facilitate the adjustment of fluid flow based on the changes in the load motion. 1 Typical

More information

Multi-function Card. 1 Description. 2 Technical data ESSK 107. 1.1 General. 1.2 Application example

Multi-function Card. 1 Description. 2 Technical data ESSK 107. 1.1 General. 1.2 Application example Multi-function Card ESSK 107 semiconductor output stages 3 power outputs 1 current measurement input 2 analogue / digital inputs 1 digital input 5 adjustments power supply 12... 30 V 1 Description 1.1

More information

Check Valves Valve locator

Check Valves Valve locator Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()

More information

Proportional Pressure Relief Valves

Proportional Pressure Relief Valves Proportional Pressure Relief Valves echnical Catalog KBCG-6-1* KBCG-8-1* Contents General Description Page 3 ypical Section Page 3 Functional Symbol Page 4 Model Codes Page 5 Operating Data Page 6 Performance

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories parker.com/pmde Pumps and Motors Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY17-8200/UK March 2004

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY17-8200/UK March 2004 Fixed and Variable Displacement Pumps, Motors and Accessories Catalogue HY17-8200/UK March 2004 F1 F2 T1 VP1 PTO info Accessories Conversion factors 1 kg 2.20 lb 1 N 0.225 lbf 1 Nm 0.738 lbf ft 1 bar 14.5

More information

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER

More information

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division Parker Piston Pumps Otsego Core Competency... Piston Pumps PAVC Series : 4 displacements from 33-100 cc/r, 207 Bar, 3000 RPM PVP Series : 9 displacements from 16-140 cc/r, 250 Bar, 3000 RPM PV Plus : 12

More information

3-Component Measuring System

3-Component Measuring System Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters

More information

PRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

PRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12 81 250/212 ED PRE3G PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS SUBPLATE MOUNTING ISO 4401-03 (CETOP 03) p max 350 bar Q max 40 l/min MOUNTING SURFACE OPERATING

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93 Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

DTC P0351 Ignition Coil "A" Primary / Secondary Circuit. DTC P0352 Ignition Coil "B" Primary / Secondary Circuit

DTC P0351 Ignition Coil A Primary / Secondary Circuit. DTC P0352 Ignition Coil B Primary / Secondary Circuit 208 2UZ-FE EINE CONTROL SYSTEM SFI SYSTEM DTC P05 Ignition Coil "A" Primary / Secondary Circuit DTC P052 Ignition Coil "B" Primary / Secondary Circuit DTC P05 Ignition Coil "C" Primary / Secondary Circuit

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100 WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Proportional Pressure Reducing Valves

Proportional Pressure Reducing Valves Proportional Pressure Reducing Valves Technical Catalog KBX(C)G-6-1* KBX(C)G-8-1* Contents General Description Page 3 Typical Section Page 3 Functional Symbols Page 4 Model Codes Page 5 Operating Data

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51 DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. 2615 N.E. 5th Avenue * Pompano Beach, Florida 33064 * U.S.A. (954)943-4243 * (954)943-7877 Fax E-mail: longline@gate.net

More information

Load-sensing control block in mono and sandwich plate design

Load-sensing control block in mono and sandwich plate design Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01 INTEGRATED CIRCUITS DATA SHEET File under Integrated Circuits, IC01 May 1992 GENERAL DESCRIPTION The is a monolithic integrated circuit for mono FM portable radios, where a minimum on peripheral components

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

GoTo Europe Focused Delivery Program. Product Overview Hydraulics GoTo Europe Focused Delivery Program Product Overview Hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times have become an important

More information

INDEX INTRODUCTION. Reference No. 10-21L-01 R E V I S E D : 2 0 0 5 0 2

INDEX INTRODUCTION. Reference No. 10-21L-01 R E V I S E D : 2 0 0 5 0 2 10-21L-01 SRM-2305, SRM-2305SI 1 1 INTRODUCTION We are constantly working on technical improvement of our products. For this reason, technical data, equipment and design are subject to change without notice.

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

330505 Low Frequency Velocity Sensor

330505 Low Frequency Velocity Sensor 330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing

More information

Jobrechner ECU-MIDI 1.0 & ECU-MAXI 1.0

Jobrechner ECU-MIDI 1.0 & ECU-MAXI 1.0 Spare parts ECU-MIDI 1.0 & ECU-MAXI 1.0 Jobrechner ECU-MIDI 1.0 & ECU-MAXI 1.0 Purpose Containing all the intelligence of the system ECU-MIDI 1.0 Previously known as JR-Fujitsu ECU-MAXI 1.0 Previously

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

Research RF Sputtering Packages

Research RF Sputtering Packages Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General

More information

PRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 3 E0.17.0703.02.01 TM GEAR PUMPS AND MOTORS INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions -

More information

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance DC/DCS Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance All DC/DCS and Dual Fan models available with internal pressure bypass DC Motor Driven Cooling Fans Are A Low Cost Solution

More information

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS

More information

Pressure and flow control system

Pressure and flow control system Pressure and flow control system RE 30030/04.09 1/32 Replaces: RE 30024/11.03 RE 30027/06.04 RE 30030/01.04 Type SYDFE1, SYDFEE, SYDFEC, SYDFEn Size 18 to 140 Component series 2X Maximum operating pressure

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

PUMP AND MOTOR DIVISION

PUMP AND MOTOR DIVISION INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE 92 500/07.00. for open circuits

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE 92 500/07.00. for open circuits RE 92 500/07.00 Replaces: 03.97 Variable isplacement Pump A11VO for open circuits izes 40 260 eries 1 Nominal pressure 350 bar Peak pressure 400 bar A11VO Index Features 1 Ordering Code / tandard Program

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

PNEUMATIC MARINE PRODUCTS FOR PROPULSION CONTROL

PNEUMATIC MARINE PRODUCTS FOR PROPULSION CONTROL PNEUMATIC MARINE PRODUCTS FOR PROPULSION CONTROL 2 Pneumatic Marine Products for Propulsion Control AVENTICS Corporation Marine Control Systems such as LOGICMASTER and GEARMASTER Propulsion Control Systems

More information

PRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 1 E0.14.0503.02.01 TM GEAR PUMPS AND MOTORS GROUP 1 INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions

More information