Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller
|
|
|
- Cleopatra Davis
- 9 years ago
- Views:
Transcription
1 Specifications Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Single Deadman Air Lifting Bag (ALB) Controller with relief valve to be purchased. The Single Deadman ALB Controller shall enable inflation of one (1) Air Lifting Bag System from a safe distance. The Single Deadman ALB Controller must be able to control an air lifting bag by activating a rocking lever to control inflation or deflation. As a minimum the system must consist of: Single Deadman ALB Controller (Equivalent to Paratech G2-150) Instruction to Bidders Bidders shall conform as much as possible to these specifications to ensure interoperability with other equipment. Exceptions or omissions must be set out in writing on a separate sheet entitled Exceptions which must accompany the bid. Failure to do so will result in an automatic rejection of the bid. The buyer shall be the sole interpreter of the intent of any clause of these specifications and shall be the sole judge as to whether the equipment or any part thereof complies with the specifications. The buyer reserves the right to reject any and all bids, to waive informalities in bidding, to negotiate small options with the successful bidder and to accept the bid, which in the opinion of the buyer, will be in its best interest. General System Construction Features The controller shall be designed for maximum portability and confined space operations. The controller shall be ergonomically shaped and equipped with a single air inlet and one air outlet. Quantity, Dimensions and Capacities Single Deadman ALB Controller (equivalent to Paratech G2-150) must be supplied with these minimum capacities: A carrying strap shall be provided to allow maximum operator mobility.
2 Weight of the Controller without a strap must not exceed = 3.04 lbs. (1.4 kg). Overall dimensions must not exceed: Width: 2.23 (2.7 cm) Height: 3.10 (7.9 cm) Length: (27.4 cm) The gauge shall be a minimum of 1.5 (3.81 cm) in diameter and must be housed by a tight-fitting protective shroud. Accuracy of the grade B gauge at 73.4 F (23 C) is 3%, 2%, 3% of span. The Single Deadman ALB Controller shall have a self-resetting relief valve to prevent accidental over-pressurization of the lift bag which activates at 150 psi (10.3 bar) with a flow rate of SCFM ( SCFH). Both the inlet and the outlet shall be spring-loaded, female, quick-connect couplings. A secondary integral threaded safety lock system on the coupling must be in place. An internal check valve shall be provided to prevent air from escaping if inlet hose is cut or damaged. The Single Deadman ALB Controller shall be equipped with an inflation and deflation rocking lever, which requires positive pressure on the end of the lever during the inflation or deflation of the lifting bag. The lever shall be color-coded with proper labels to denote the function of the valve. The forward button must be for inflating and the rear button for deflating. The controller body must allow for the attachment of additional Single ALB Controllers in series with (1) air inlet and multiple outlets, that require: (1) Distributor Module (equivalent to Paratech ) per additional Controller, (4) Connecting Screws (equivalent to Paratech ) for the first two Controllers and then (2) extra screws per additional unit. Only (1) Distributor End Module (equivalent to Paratech ) and (2) Hex Lock Nuts (equivalent to Paratech ) are needed for any multiple configurations. It is required that the equipment meets or exceeds the EN Lifting Bag Systems for fire and rescue service use - Safety and performance requirements.
3 Specifications Dual Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Dual Deadman Air Lifting Bag (ALB) Controller with relief valve to be purchased. The Dual Deadman ALB Controller shall enable inflation of one (1) or two (2) Air Lifting Bag Systems from a safe distance. The Dual Deadman ALB Controller must be able to control an air lifting bag by activating a rocking lever to control inflation or deflation. As a minimum the system must consist of: Dual Deadman ALB Controller (Equivalent to Paratech G2-150) Instruction to Bidders Bidders shall conform as much as possible to these specifications to ensure interoperability with other equipment. Exceptions or omissions must be set out in writing on a separate sheet entitled Exceptions which must accompany the bid. Failure to do so will result in an automatic rejection of the bid. The buyer shall be the sole interpreter of the intent of any clause of these specifications and shall be the sole judge as to whether the equipment or any part thereof complies with the specifications. The buyer reserves the right to reject any and all bids, to waive informalities in bidding, to negotiate small options with the successful bidder and to accept the bid, which in the opinion of the buyer, will be in its best interest. General System Construction Features The controller shall be designed for maximum portability and confined space operations. The controller shall be ergonomically shaped and equipped with a single air inlet and dual air outlet. Quantity, Dimensions and Capacities Dual Deadman ALB Controller (equivalent to Paratech G2-150) must be supplied with these minimum capacities: A carrying strap shall be provided to allow maximum operator mobility. Weight of the Controller without a strap must not exceed = 4.6 lbs (2.1 kg).
4 Overall dimensions must not exceed: Width: 3.81 (9.68 cm) Height: 3.27 (8.31 cm) Length: (26.34 cm) The controller shall be equipped with two (2) multi-colored operating gauges. The gauges shall be a minimum of 1.5 (3.81 cm) in diameter and must be housed by a tight-fitting protective shroud. Accuracy of the grade B gauge at 73.4 F (23 C) is 3%, 2%, 3% of span. The controller shall have a self-resetting relief valve to prevent accidental overpressurization of the lift bag which activates at 150 psi (10.3 bar) with a flow rate of SCFM ( SCFH). Both the inlet and the outlet shall be spring-loaded, female, quick-connect couplings. A secondary integral threaded safety lock system on the coupling must be in place. An internal check valve shall be provided to prevent air from escaping if inlet hose is cut or damaged. The Dual Deadman ALB Controller shall be equipped with two (2) each independently operated inflation and deflation rocking levers, which require positive pressure on the end of the lever during the inflation or deflation of the lifting bags. Each of the two (2) push levers shall be color-coded with proper labeling to denote the function and pressure limit of the valve with slip-resistant up & down rocker buttons. The forward button must be for inflating, rear for deflating. It is required that the equipment meets or exceeds the EN Lifting Bag Systems for fire and rescue service use - Safety and performance requirements.
5 Specifications Pressure Regulator 5, psi ( bar) Introduction These purchase specifications cover the minimum requirements of a Pressure Regulator with a self-resetting relief valve to be purchased. The Pressure Regulator shall be capable of reducing inlet pressure of 5,500 psi (379 bar) to a constant working pressure of 200 psi (13.8 bar). The Pressure Regulator must be piston-type designed primarily for use with an SCBA air cylinder. As a minimum the system must consist of: Pressure Regulator (Equivalent to Paratech G2) Instruction to Bidders Bidders shall conform as much as possible to these specifications to ensure interoperability with other equipment. Exceptions or omissions must be set out in writing on a separate sheet entitled Exceptions which must accompany the bid. Failure to do so will result in an automatic rejection of the bid. The buyer shall be the sole interpreter of the intent of any clause of these specifications and shall be the sole judge as to whether the equipment or any part thereof complies with the specifications. The buyer reserves the right to reject any and all bids, to waive informalities in bidding, to negotiate small options with the successful bidder and to accept the bid, which in the opinion of the buyer, will be in its best interest. General System Construction Features The Pressure Regulator shall be designed to reduce the pressure from a high-pressure air source to a suitable working pressure for use with an Air Lifting Bag System. The Pressure Regulator shall be of piston-type design and equipped with a 347/346 CGA inlet and ¼ NPT male nipple outlet. Quantity, Dimensions and Capacities Pressure Regulator (equivalent to Paratech G2) must be supplied with these minimum capacities: Weight of the Pressure Regulator must not exceed = 3.62 lbs (1.64 kg).
6 Overall dimensions must not exceed: Width: 5.77 (14.7 cm) Depth: 3.52 (8.9 cm) Length: 6.05 (15.2 cm) The Pressure Regulator shall be equipped with two (2) operating gauges. One gauge shall monitor the supplied high pressure air with corresponding markings up to 6000 psi (400 bar). The second gauge shall monitor the outlet pressure with corresponding markings up to 400 psi (28 bar).the gauges shall be a minimum of 1.5 (3.81 cm) in diameter and must be housed by a tight-fitting protective shroud. Accuracy of the grade B gauge at 73.4 F (23 C) is 3%, 2%, 3% of span. The Pressure Regulator shall have a self-resetting relief valve to prevent accidental over-pressurization of the lift bag which activates at 200 psi (13.8 bar) with a flow rate of 9.55 SCFM (270.5 SLM). The Pressure Regulator shall be equipped with a psi (13.8 bar) manual adjusting knob and have the ability to vent pressure when adjusting down the pressure (counterclockwise rotation). The Pressure Regulator shall be equipped with a 90 lever shut-off valve to disengage the air flow to the outlet. The lever positions shall be clearly marked with color-coded labels to indicate on and off points. It is required that the equipment meets or exceeds the EN Lifting Bag Systems for fire and rescue service use - Safety and performance requirements.
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA. REF. 10049600 Rev. L
REF. 10049600 Rev. L Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA TABLE OF CONTENTS WARNINGS 2 DESCRIPTION AND MECHANICAL ASSEMBLY 2 CONNECTION
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
Rack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
Brookings Fire Dept. SCBA Specifications
Brookings Fire Dept. SCBA Specifications GENERAL Bids are requested for forty-three (43) 4500 psi 60-minute-rated cylinder self-contained breathing apparatus (SCBA) with a spare cylinder for each SCBA
Paratech s MULTIFORCE Air Lifting Bag takes lifting to a whole new level. Integrating the latest technology with a unique understanding of lifting,
Paratech s MULTIFORCE Air Lifting Bag takes lifting to a whole new level. Integrating the latest technology with a unique understanding of lifting, Paratech has designed the MULTIFORCE Air Lifting Bag
Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION
Outdoor Cooking Gas pressure Regulators & Accessories 2012 EDITION RE-02 Outdoor cooking Product index 1 - Introduction P.4 1.1 Gas pressure regulators P.4 1.2 Low pressure installations P.4 1.3 High pressure
Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves
Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Features Top guided design offers high capacity with 0.110 in 2 [0.710 cm 2 ] orifice area.
GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.
GAS CYLINDER SAFETY Contents 1. INTRODUCTION 2. GRADES OF GASES 3. PRESSURES 4. TYPES OF REGULATORS 5. CYLINDER TRANSPORT 6. STORAGE 7. KEEPING THE SYSTEM SAFE 8. PROBLEM REGULATORS OR ATTACHMENTS 9. FURTHER
HYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
VW Caddy W21-760-3503 INSTALLATION INSTRUCTIONS
Unit 626 Kilshane Avenue, North West Business Park, Ballycoolin, Dublin 15, Ireland Telephone: +353 1 8612 632, Fax: +353 1 8612 647, email: [email protected] www.driveriteltd.com VW Caddy W21-760-3503
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
TECHNICAL DATA. 30a. September 18, 2009 1-1/4-8 (DN32 - DN200)
September 18, 2009 30a 1. DESCRIPTION Viking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1/4, 1-1/2, 2, 2-1/2, 3, 4, 6 and 8 for commercial systems. They are available with an
Instruction Manual. A50099 Calibration Device. www.band-it-idex.com TIE-DEX CALIBRATION DEVICE A50099
Instruction Manual TIE-DEX CALIBRATION DEVICE Introduction: The Tie-Dex is to be used with the A30199, A40199, A35199, and A35599 Tools using BAND-IT Tie-Dex ties only. Table of Contents: 1. Introduction
SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / [email protected] / +31 183 639193
Nozzles and portable monitors Rosenbauer - Nozzles and portable monitors EN Maximum extinguishing effect. Minimal water consumption. The Rosenbauer nozzle enables the manual adjustment of the water flow
How To Use Vetter Mini Lifting Bags
O P E R A T I N G I N S T R U C T I O N S Vetter Mini-Lifting Bags 8.0 bar Item No. 9987 0153 01 Vetter GmbH State: 08/08 Vetter Mini-Lifting Bags 8.0 bar Page: 2 Contents Preliminary remarks Page 3 Safety
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.
May 3, 2013 Foam 138a 1. DESCRIPTION Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specific design area upon system activation. These are suitable for use
ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
WARNING CANADIAN D.O.C. WARNING
Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison Corp. reserves the right to make changes in the product, the programs, and
Porter Instrument Division
AA173200i Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA Tel: 215-723-4000 Ref. 10545100 Rev. F CE Notice The symbol on this product indicates compliance
Installing a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
UNIVERSAL 1550 PRE-MIX DISPENSER
MODEL NO. 284974xxx 1 of 8 Control Code A ªIMI Cornelius Co., 1987-95 22 5 6 2 3 7 4 1 26 32 19 28 33 29 27 11 15 18 16 17 14 9 31 30 34 24 20 23 8 10 21 13 FIGURE 1. ASSEMBLY ªIMI Cornelius Co., 1987-95
Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical
Thickness Gauges Technical Data for Metric Thickness Gauges Page Model Lifting Contact points Contact points mm mm mm device standard available on request 130 K 15 0.1 10 15 no 6.35 mm Ø flat Ø flat, 130
needle valves Needle Valves Index At a Glance 1
Needle Valves Index At a Glance 1 1700 Series 5 Forged Body, Integral Bonnet Needle Valves 2100 Series 8 Bar Stock, Screwed Bonnet Needle Valves 2200 Series 12 Bar Stock, Screwed Bonnet Needle Valves 2219
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
FILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
Oxygen & Nitrogen. Oxygen & Nitrogen Service Catalog. Parts & Complete Systems
Oxygen & Nitrogen Oxygen & Nitrogen Service Catalog Parts & Complete Systems Why buy our carts? Whether you need a complete system or just a few items, our knowledgeable technical staff can custom configure
Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators
Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators General information The Manual Handling Operations Regulations 1992 (updated 1998) came into force in January 1993. The
OWNER S/OPERATOR S - PARTS MANUAL CEMENT MIXER MODEL MX-80
OWNER S/OPERATOR S - PARTS MANUAL CEMENT MIXER MODEL MX-80 Read the Operator s Manual entirely. When you see this symbol, be aware that the subsequent instructions and warnings are serious - follow without
FAG Hydraulic nuts. Technical Product Information
FAG Hydraulic nuts Technical Product Information Contents Application 2 Design 2 Design variants 3 Pressure generators, connectors 4 Dimension tables for FAG hydraulic nuts (metric) 6 Dimension tables
P900 SERIES PORTABLE HYDROSTATIC TESTER
P900 SERIES PORTABLE HYDROSTATIC TESTER MODELMODEL P900-SM ( STANDARD MODEL) SHOWN IN PHOTO coated square tubular frame on wheels for easy transport. PANEL MOUNTED CONTROLS: 4 dial gauges, pump regulator
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications
Instruction Manual Form 5753 Type HSR February 014 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications P154 TYPE HSR ANGLE BODY P175 TYPE HSR STRAIGHT Figure 1.
CHIPPING HAMMERS. 9949 Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.
CHIPG HAMMERS Website: www.apt-tools.com e-mail: [email protected] TDS-1056 Rev A CHIPG HAMMERS TOOL MAINTENANCE & REPAIR INFORMATION FIELD OPERATION: Before use: 1. On 650 Series tools, tighten the handle
6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
Installation and maintenance instructions
Installation and maintenance instructions Indirect fired domestic hot water tank Logalux ST50/ ST300/ For heating contractors Please read carefully prior to installation and maintenance. 7 747 00 883 09/006
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
Section 8 Storage Tanks & Equipment
Section Storage Tanks & Equipment Table of Contents Section Storage Tanks & Equipment Above Ground Horizontal Tanks... -1-4 Containment Sumps...-5 Fillrite AC & Transfer Pumps... -9-10 Fillrite Diesel
Rack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
G234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;
Fluid Monitoring and Inventory Management
SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems
Proportional Relief Valves
www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to psig (0.7 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves Spring
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.
ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging
Hose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual. B bestflangespreader
EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual B bestflangespreader com INDEX THE EQUALIZER RANGE OF MECHANICAL & HYDRAULIC SPREADING
REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION
REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION English version 11/ 2 010 REGSON TM2 The REGSON TM2 pressure regulator,
SAFETY SAFETY APPAREL 20,000 PSI
SAFETY APPAREL TurtleSkin Water Armor is designed for UHP safety. Protection up to 2800 bar or 40,000 psi One size fits all money-saving design Modular design allows you to buy only what you need Replacement
INDIRECT WATER HEATER. Installation and Operating Instruction Manual
INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Series 30000 Hose Reels
Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are
413 NOVA SYSTEM PAN AMERICAN TOOL CORPORATION 5990 NW 33309-2208 PHONE (954)735-8665 TOLL FREE 1-800-423-2764 FAX
413 NOVA SYSTEM 5990 NW 31st Avenue Ft. Lauderdale, Florida 33309-2208 PHONE (954)735-8665 TOLL FREE 1-800-423-2764 FAX (954)735-8668 2013 Pan American Tool Corporation 2013 TERMS AND CONDITIONS TERMS:
Baumann 24000 Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VGBQ SERIES CONVERSION KIT VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662) 455-1200 IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning,
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Chief S21M PARTS MANUAL. 2005 Chief Automotive Technologies
Chief SM 00 Chief Automotive Technologies Chief s Limited One-Year Warranty & Liability CHIEF'S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Technologies, Inc. warrants for one year from date
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
Technical Data. Installation
Technical Services: Tel: (800) 81-91 / Fax: (800) 791-5500 Model 51 (1) Riser Manifold 1-1/ thru 6 Inch (DN40 thru DN150) For NFPA 1 Sprinkler Systems General Description The Figure 51 (1) Riser Manifolds
Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.
IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation
Installation Instructions
Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation
INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303
WATER MIST HAND PORTABLE FIRE EXTINGUISHERS Model B270 ¾ Gallon Model B272 2 ½ Gallon INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 6303 All fire extinguishers should be installed, inspected
INSTALLATION AND SERVICE MANUAL
CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100
Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA
Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 1607 DAYTONA Congratulations! All of us at Summit Dental Systems want you to know that your 1607 Daytona Cuspidor has been built with
Installing Cisco TelePresence MX200 G2 - Wheel Base
This installation guide covers MX200 G2 with a wheel base. Dimensions Height: 1480 mm / 58.3 in. Width: 995 mm / 39.2 in. Depth: 715 mm / 28.0 in. Weight total: 33 kg / 73 lb Weight monitor: 24 kg / 53
copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool
copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool CFD Companies currently assigned to receive 24 new TNT Forcible Entry Tools: 1) All 11 Hook and Ladder and Tower companies. 2) *All single-engine
For over 40 years, the leader in. nitrous oxide. equipment technology.
Conscious Sedation Delivery Systems For over 40 years, the leader in nitrous oxide equipment technology. Made in U.S.A. Over 40 years ago Fraser Sweatman pioneered the technology used for safe delivery
SPECIAL FEATURES. Air- Electric Clutch Control. Extended Beds and Rams
, SPECIAL FEATURES Extended Beds and Rams Beds and rams can be extended at both ends or at one end only for closing or "homing" operations. Extensions at both ends of the machine provide greatly increased
Industrial Torque Solutions
Industrial Torque Solutions Who we are One Company, Total Support, Complete Solutions Over many years Hydratight has provided world class bolted joint solutions and continues to set international standards
TAMPERS. 9949 Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.
TAMPERS Website: www.apt-tools.com e-mail: [email protected] TDS-1064 Rev A S TOOL MAINTENANCE & REPAIR INFORMATION FIELD OPERATION: Before use: 1. Check the tamping butt lock screw, it must be tightened
Itho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)
Features 1. Differential latching clapper-type, lightweight, dependable construction. 2. Low Air Pressurized System, psi -to- 2 psi (0.6 bar -to- 1.9 bar) Max 3. Reset externally. Cover removal is not
QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview
Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
LINDGREN-PITMAN, INC. Super Spool III Installation Instructions
LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. 2615 N.E. 5th Avenue * Pompano Beach, Florida 33064 * U.S.A. (954)943-4243 * (954)943-7877 Fax E-mail: [email protected]
SERVICE MANUAL. Product No. P1320
SERVICE MANUAL Procedural Recliner From Hill-Rom Product No. P1320 For Parts Or Technical Assistance man132ra USA (800) 445-3720 Canada (800) 267-2337 International: Contact your distributor. Procedural
FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com
OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved
Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)
Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
Operating, Installation, and Maintenance Instructions
ELKHART BRASS MFG. CO., INC. 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 Operating, Installation, and Maintenance Instructions RAM Personal Portable Monitor
MP-4V Heavy Duty Riveter / 39048
MP-4V Heavy Duty Riveter / 39048 This newly designed heavy-duty air/hydraulic riveter is ergonomically designed with the professional in mind. The light weight 3.7 lbs. well balanced MP-4V includes a Vacuum
TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V
TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
1300 MAXTRAK SPECIFICATION
CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having
Rack Installation Instructions
Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the
Fluid Regulator. Instructions Parts List 306563L LOW PRESSURE
Instructions Parts List LOW PRESSURE Fluid Regulator 306563L For accurate, positive control of fluid pressure to one spray gun, dispensing valve, or atomizing head. For professional use only. 250 psi (18
DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT
DENTAL CHAIR AND UNIT SP- CIELA OPERATING MANUAL IMPORTANT This manual provides operating instruction for BELMONT SP-CIELA. The instructions contained in this booklet should be thoroughly read and understood
KF Needle & Gauge Valves
KF Needle & Gauge Valves Superior Fluid Control Products KF O-Ring & Packed Stem Style Needle Valves KF Needle Valves combine rugged construction, dependability and leak-free performance at high and low