Minicap FTC260, FTC262
|
|
|
- Ralf Anthony
- 9 years ago
- Views:
Transcription
1 Technical Information Minicap FTC260, FTC262 Capacitive Limit Detection Compact switch for limit detection with active build-up compensation; No calibration necessary Version available for dust explosion areas Applications Minicap is designed for limit detection of light bulk solids, with a grain size up to max. 30 mm and a dielectric constant ε r 1.6, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum. Versions: Minicap FTC260 (left): with 140 mm rod probe, with FDA listed material; for bulk solids and liquids Minicap FTC262 (right): with max. 6 m rope probe; for bulk solids Relay output (potential-free change-over contact / SPDT) with AC or DC power PNP output with three-wire DC power Your Benefits Complete unit consisting of the probe and electronic insert: simple mounting no calibration on start-up Active build-up compensation accurate switch point even with heavy build-up on the probe high operational safety Mechanically rugged no wearing parts long operating life no maintenance The rope probe of the Minicap FTC262 can be shortened optimum matching to the measuring point in the silo less stocks required TI 287F/00/en
2 Table of contents Function and system design General Information Measuring principle Measuring System Input Measured variable Measuring range Output Output signal Signal on alarm Switching delay when free or covered Overvoltage category Protection class Power supply Electrical connection Supply voltage Terminal compartment Performance characteristics Reference operating conditions Hysteresis Switch point Power up response Long-term drift Influence of medium temperature Human interface Display elements Operating elements Certificates and approvals CE approval Ex approval Overspill protection FTC Ordering information Product structure FTC Product structure FTC Accessories Adapter Transparent cover Rope shortening set Supplementary documentation Operating manual (BA) Safety instructions (XA) Operating conditions Installation Installation instructions FTC Installation instructions FTC Environment Ambient temperature range T Ambient temperature limits Storage temperature Climate class Degree of protection Shock resistance Vibrational resistance Electromagnetic compatibility Process Process temperature range T Process temperature limits Process pressure range pe Temperature diagrams Mechanical construction Design, Dimensions (in mm) Material for wetted parts Process connections Housing Endress+Hauser
3 Function and system design General Information Technical specifications to DIN Measuring principle Limit Detection A metal plate at the end of the probe, within the insulation, and the integrated counter-electrode together with the surroundings combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the Minicap switches. Active Build-up Compensation The Minicap detects build-up on the probe and compensates for its effects so that the switch point is always accurate. The effects of build-up compensation depend on: the thickness of the build-up on the probe, conductivity of the material, the sensitivity setting on the electronic insert. Setting the Sensitivity The Minicap is so calibrated at the factory that it correctly switches in most cases. Greater sensitivity can be set using a multi-pole switch on the electronic insert. This is only necessary, however,if there is very strong build-up on the probe, or if the dielectric constant of the material ε r is very small. LEDs MIN MAX A B C D FTC V 45V DC DC PNP I max 200 ma Switch position Maximum fail-safe Sensitivity Factory setting on switches L00-FTC26xxx xx-en-001 Endress+Hauser 3
4 Function Range There is a loose relationship between the dielectric constant ε r and density ρ of the material. However, this depends on the solid. The table on the left indicates whether the Minicap can be used or if application limits are exceeded. Grain, seed, legumes and their products Examples ρ in g/l (approx.) ε r (approx.) Function Rice yes Cornstarch (packed) yes Flour (wheat) yes Corn grist yes Sunflower seeds yes Noodles yes Bran (wheat) yes Popcorn 30 1,1 no Minerals, inorganic materials Cement yes Plaster yes Chalk (packed) (yes) Chalk (loose) no Plastics ABS granulate yes PA granulate yes PE granulate no PVC powder no PU-PU dust no Grey background: Application limits of Minicap exceeded. Recommendation: Soliphant FTM to be used. In general: If the dielectric constant of the solid is not known, then the density (apparent weight) of the solid is a deciding factor. Under normal conditions the Minicap functions in foodstuffs with a density of 250 g/l and above or in plastic or mineral materials with a density of 600 g/l and above. 4 Endress+Hauser
5 Minimum/Maximum Fail-Safe Mode The Minicap FTC260 can be set to minimum or maximum fail-safe mode (see following table). AC or DC version with relay output (potential-free change-over contact): Maximum fail-safe mode: The relay is de-energised when the probe is covered or the power supply fails. Minimum fail-safe mode: The relay is de-energised when the probe is free or the power supply fails. DC version with PNP output: Maximum fail-safe mode: The switch output is blocked when the probe is covered or the power supply fails. Minimum fail-safe mode: The switch output is blocked when the probe is free or the power supply fails. Switch position Level Relay output SPDT Transistor output PNP Red LED for switching status Green LED for stand-by Probe covered L+ Relay de-energised blocked Maximum fail-safe mode L+ 3 + Probe free Relay energised connected L+ 3 + Probe covered Relay energised connected Minimum fail-safe mode Probe free Relay de-energised 1 3 L+ blocked Power failure U 0 V Relay de-energised 1 3 L+ blocked Selecting the switch position and function L00-FTC26xxx xx-en-002 Endress+Hauser 5
6 Measuring System Minicap is an electronic switch. The complete measuring system consists of: the Minicap FTC260 or FTC262 a power supply and controllers, switching devices, signal transmitters (e.g. lamps, horns, PCS, PLC, etc.) FTC262 FTC260 MAX MIN FTC260 Limit detection in silos containing solids L00-FTC26xxx xx-xx Endress+Hauser
7 Input Measured variable Limit detection Measuring range FTC260: ε r 1.6 FTC262: ε r 1.5 Output Output signal Signal on alarm Switching delay when free or covered DC, PNP transistor output: Switching: PNP I max 200 ma overload and short circuit protection residual voltage at transistor at I max < 2.9 V AC / DC, Relay output: Contact: change-over, potential-free U~ max 253 V, I~ max 4 A (AC) P~ max 1000 VA, cos ϕ = 1 P~ max 500 VA, cos ϕ > 0.7 I% max 4 A up to U% 30 V (DC) I% max 0.2 A up to U% 253 V (DC) DC, PNP transistor output: < 100 µa AC / DC, Relay output: relay de-energised FTC260: 0.5 s FTC262: 0.8 s Overvoltage category Category III (EN 61010) Protection class Protection class to EN FTC260: Class II FTC262: Class I Power supply Electrical connection To ensure that the Minicap operates safely and without electrical interference, it must be connected to an earthed silo with metal or reinforced concrete walls. For silos made of non-conductive materials, the external earth wire of the Minicap must be connected to a conductive and earthed component which is earthed near to the silo. The protective earth can be connected to the internal earth terminal of the Minicap. Connections can be made with standard instrument cabling. See TI 241F/00/en for information on EMC (testing procedures, installation). Connect the potential matching lead (PAL) when using in dust explosion hazardous areas. Note national regulations! Endress+Hauser 7
8 Minicap AC or DC connection and relay output F1: Fine-wire fuse to protect the relay contact, dependent on the connected load F2: Fine-wire fuse, 500 ma M: Earth connection to silo or metal components on silo E: Earth M EX E F1 F2 PAL L1 N PE or U~ L+ L max. 253 V/ 4 A max VA, cos = 1 U~ V U V U... max. 30 V/ 4 A max. 253 V/ 0,2 A No ground lines (PE) or potential matching lines (PAL) are required with Minicap FTC260. L00-FTC26xxx xx-en-001 Minicap with three-cable DC connection; Transistor output PNP F: R: M: E: Fine-wire fuse, 500 ma Connected load, e.g. PLC, PCS, relay Earth connection to silo or metal components on silo Earth EX E M F PAL R max. 200 ma L+ L PE U... 10,8 45 V L00-FTC26xxx xx-xx-001 Minicap is protected against reverse polarity. The green LED for standby goes out if the connections are reversed. No ground lines (PE) or potential matching lines (PAL) are required with Minicap FTC260. Supply voltage Terminal compartment DC, PNP transistor output: U% V transient pulses to 55 V current consumption max. 30 ma reverse polarity protected AC/ DC, Relay output: U~ V or U% V current consumption max. 130 ma Stranded wires max. 1.5 mm 2 in end sleeves Electric wire max. 2.5 mm 2 8 Endress+Hauser
9 Performance characteristics Reference operating conditions Hysteresis Switch point Power up response Long-term drift Influence of medium temperature (for plastic vessels) Ambient temperature: 23 C Medium temperature: 23 C Medium pressure p e : 0 bar Medium: dielectric constant ε r = 2.6 Conductivity: < 1 µs Sensitivity setting: C FTC260: Horizontal 4 mm, Vertical 7 mm FTC262: Vertical 5 mm FTC260: Horizontal: centre of probe 5 mm, Vertical: 40 mm above probe tip FTC262: Vertical: 35 mm above probe tip FTC260: Correct switching aftermax. 1.5 s FTC262: Correct switching after max. 2 s FTC260: Horizontal 3 mm, Vertical 6 mm FTC262: Vertical 6 mm FTC260: Depending on material to be measured FTC262: Depending on material to be measured Operating conditions Installation Silo Material The Minicap can be installed in a wide range of silos made of different materials (e.g. metal, plastic, concrete). Mounting Point Note the angle of the material mounds and the outlet funnel when determining the mounting point or probe length of the FTC262. The Minicap switches when the probe tip is covered by a few centimeters of material or when it is free. Material flow should not be directed at the probe. Endress+Hauser 9
10 Installation instructions FTC260 Correct Installation Incorrect Installation Max. 25 d) min. 200 a) max. 50 min. 100 e) b) f) Min. max N c) min. 200 General information and recommendations for installing the Minicap FTC260 limit switch (Dimensions in mm) L00-FTC26xxx xx-xx-001 Correct Installation a. Minimum distance: To prevent mutual interference with the FTC260, the probes must be at least 200 mm from each other. b. Mounting point: The tip of the probes must point slightly downwards so that the material can slide off more easily. The protective cover protects the probe rod from collapsing mounds or mechanical strain at the outflow when the Minicap FTC260 is set to minimum detection. c. Mechanical load: The maximum lateral load on the probe rod must be taken into account when used for minimum detection. It should therefore only be used for minimum detection with loose materials that have good flow characteristics. Incorrect Installation d. The probe can be damaged by the inflowing material and cause faulty switching. Cable gland pointed upwards can allow moisture to enter. e. Threaded socket too long with material build-up on the silo wall. (less than the minimum mounting depth of 100 mm). f. Mounted near build-up in the silo. The probe tip is too near to a silo wall (less than a minimum distance of 200 mm). 10 Endress+Hauser
11 Installation instructions FTC262 Correct Installation a) Incorrect Installation d) e) Max. min. 300 b) f) min. 300 max N c) FTC260 min. 300 g) Min. min. 200 max N General information and recommendations for installing the Minicap FTC262 limit switch (Dimensions in mm) L00-FTC26xxx xx-xx-002 Correct Installation a. Minimum distances: Sufficent distance from the material filling curtain and the other probe. b. Mounting point: Do not install in the centre of the outlet cone. Ensure there is sufficient distance from the silo wall and from material build-up on the wall. c. Mechanical load: Note the tensile strain on the probe rope and the strength of the silo roof when used for minimum detection. Very high tensile forces may occur at the material outlet especially with heavy, powdery bulk materials which tend to form build-up. These forces are significantly greater over the outlet than at the silo wall. For minimum detection Minicap FTC262 should only be used for light, easily flowing solids, and that do not tend to form build-up. Incorrect Installation d. In the centre of the material outflow; the high tensile forces at this point may tear off the probe or damage the silo roof. e. The probe may be damaged by inflowing material. f. Mounted laterally g. Too near silo wall; when swinging gently the probe can hit the wall or touch any build-up which may have formed. This can result in error switching Endress+Hauser 11
12 Environment Ambient temperature range T1 Ambient temperature limits Storage temperature C ( F) ( +60 C, Dust-Ex version] (see the temperature diagrams) C ( F) ( +60 C, Dust-Ex version] (see the temperature diagrams; grey background) C ( F) Climate class IEC 68 part 2-38 Degree of protection Shock resistance IP66 Probe: 7 J Vibrational resistance EN (IEC ), Hz, spectral rate of velocity 0.5, 100 min per axis Electromagnetic compatibility Interference Emission to EN 61326, Electrical Equipment Class B Interference Immunity to EN 61326, Annex A (Industrial) and NAMUR Recommendation NE 21 (EMC) See TI 241F/00/en for general instructions regarding the EMC test conditions for E+H instruments. Process Process temperature range T2 Process temperature limits Process pressure range p e Temperature diagrams FTC260: C ( F) ( +80 C, Dust-Ex version) FTC262: C ( F) (see the temperature diagrams) FTC260: C ( F) ( +80 C, Dust-Ex version) FTC262: C ( F) (see the temperature diagrams; grey background) FTC260: bar ( 14, psi) FTC262: 1 +6 bar ( 14,5 +90 psi) FTC260 T1 C EX T1 C 60 EX T2 C T2 C L00-FTC26xxx xx-xx-001 FTC262 T1 C EX T1 C 60 EX T C T2 C L00-FTC26xxx xx-xx Endress+Hauser
13 Mechanical construction Design, Dimensions (in mm) Minicap FTC260 Minicap FTC262 ø94 ø94 max. 100 max. 100 ~90 41 AF ~95 50 AF 1 NPT 1 BSPT (R 1) ~20 1½ NPT 1½ BSPT (R 1½) ~25 78 Wall thickness ø8 32 Lmin. 500, Lmax max. ø42 L00-FTC26xxx xx-en-001 Adapter for FTC260 ~ AF PPS 40 1½ BSPT / 1½ BSP (R 1½ /G1½) L00-FTC26xxx xx-en-003 Probe length tolerances: Probe length L Tolerances bis 1000 mm +0, 10 mm bis 3000 mm +0, 20 mm bis 6000 mm +0, 30 mm 32 L00-FTC26xxx xx-en-002 Endress+Hauser 13
14 Material for wetted parts Probe rod FTC260: PPS = Polyphenylene sulphide (glass fibre content approx. 40%), FDA listed Probe length: FTC260: 140 mm, FTC262: min. 500 mm, max mm Flexural strength FTC260: 1400 N (at probe tip) Probe rope FTC262: Surface in High Density PE over steel coating Other probe parts FTC262: PPS = Polyphenylene sulphide (glass fibre content approx. 40 %) Tensile strength F of FTC262: Max N up to 40 C, max N at 80 C F N T2 C L00-FTC26xxx xx-xx-003 Process connections Housing Threaded boss: FTC260: 1 BSPT (R 1, ISO 7/1); Adapter for 1½ BSPT and 1½ BSP (G 1½) see accessories 1 NPT, ANSI B ; Adapter for 1¼ NPT see accessories FTC262: 1½ BSPT (R 1½, ISO 7/1) 1½ NPT, ANSI B Housing F14: Polyester PBT-FR, IP66 Human interface Display elements Operating elements Green LED: stand-by Red LED: switch status Switch on electronic insert switching between minimum and maximum fail-safe mode sensitivity setting (depends on the dielectric constant ε r and build-up). A sensitivity adjustment is normally not required (see section "Measuring principle") Certificates and approvals CE approval Ex approval Overspill protection FTC260 In attaching the CE Mark, Endress+Hauser confirms that the device conforms to all relevant EU directives. ATEX, FM, CSA See section Product structure DIBt, General design approval 14 Endress+Hauser
15 Ordering information Product structure FTC Approval A Non-hazardous area D Non-hazardous area, WHG B ATEX II 1/3 D U CSA, General purpose S CSA, DIP Cl. II Gr. E-G, Cl. III J FM, DIP Cl. II, III Gr. E-G, T5 Y Special version 20 Process connection A Thread DIN2999 R 1, PPS B Thread ANSI NPT 1, PPS Y Special version 30 Switch output 2 3-wire PNP V DC 4 Relay V AC / V DC 9 Special version 40 Housing, Cable entry B F14 Polyester IP66 Gland M20 C F14 Polyester IP66 Thread NPT ½ D F14 Polyester IP66 Thread G ½ Y Special version 50 Additional option 1 Basic version 2 Transparent cover 9 Special version FTC260 Product designation Endress+Hauser 15
16 Product structure FTC Approval A Non-hazardous area B ATEX II 1/3 D U CSA, General purpose S CSA, DIP Cl. II, III Gr. G+coal dust Cl. III J FM, DIP Cl. II, III Gr. E-G, T5 Y Special version 20 Process connection A Thread DIN2999 R 1 ½, PPS B Thread ANSI NPT 1 ½, PPS Y Special version 30 Probe length, L= mm ( inch) 1... mm L ( mm) steel HD-PE insulated 2... inch L ( inch) steel HD-PE insulated mm ( 59 inch) steel HD-PE insulated mm ( 98 inch) steel HD-PE insulated mm (157 inch) steel HD-PE insulated mm (236 inch) steel HD-PE insulated 9 Special version 40 Switch output 2 3-wire PNP V DC 4 Relay V AC / V DC 9 Special version 50 Housing, Cable entry B F14 Polyester IP66 Gland M20 C F14 Polyester IP66 Thread NPT ½ D F14 Polyester IP66 Thread G ½ Y Special version 60 Additional option 1 Basic version 2 Transparent cover 9 Special version FTC262 Product designation 16 Endress+Hauser
17 Accessories Adapter Transparent cover Rope shortening set FTC260, 1 BSPT female (R c 1), ISO 7/1 (see dimensional sketch): Part No.: , for 1½ BSPT (R 1½ ISO 7/1), PPS Part No.: , for 1½ BSP (G 1½ DIN ISO228), PPS FTC260, 1 NPT female: Part No.: , for 1¼ NPT, steel Part No.: , for 1¼ NPT, AISI 316Ti (1.4571) FTC260/262: Part No.: FTC262: Part No.: Supplementary documentation Operating manual (BA) Safety instructions (XA) Minicap FTC260 KA093F/00/a Minicap FTC262 KA155F/00/a Rope shortening set for FTC262 KA157F/00/a6 Safety instructions (ATEX) for FTC260 XA011F/00/a3 4 0 II 1/3 D Safety instructions (ATEX) for FTC262 XA092F/00/a3 4 0 II 1/3 D Endress+Hauser 17
18 18 Endress+Hauser
19 Endress+Hauser 19
20 International Head Quarter Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str Weil am Rhein Deutschland Tel Fax [email protected] TI287F/00/en/05.04 SL/FM + SGML6.0 ProMoDo
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Level Switch soliphant II FTM 30, FTM 31, FTM 32
Technical Information TI 29F/2/ae Level Switch soliphant II FTM 0, FTM, FTM 2 Cost-effective vibration level switch for fine-grained bulk solids Application Soliphant II is a rugged level switch for use
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Nivotester FTC325. Technical Information. Level limit switch With Intrinsically Safe Signal Circuit for Connection to a Capacitance Sensor
Technical Information Nivotester FTC325 Level limit switch With Intrinsically Safe Signal Circuit for Connection to a Capacitance Sensor Applications Level limit detection in tanks containing liquids and
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
CAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.
ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau
KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
S300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
ph/redox Measurement MyPro CPM 431
Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
PHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
Safety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an